Home
MOD. RA RP cable
Contents
1. N 01 Allen Screws N 02 nuets 5 N 02 washers 5 M5x16 M5x25 M6x12 Allen tools RA RP Cable WU150 REV 00 15 05 2013 12 WUNDER SA BI SRL USER MANUAL Picture 3 3a assemble the height rod on black abs support with screws C and allen tools kit Picture 3b The height rodi s ready for use Pull up the height meter rod Press the black button and measuring height and push down Position it horizontally Lower the rod up to the point where the lever rests head Position it horizontally touches the patient s head The height can be read at the point A Lower the rod up to the point in which the blade rests head touches the patient s head The height can be read at point B RA RP Cable WU150 REV 00 15 05 2013 13 WUNDER SA BI SRL USER MANUAL 17 THERMAL PRINTER OPTIONAL AN Read this manual carefully before using the instrument Platen Rollen Roll Holder FO RA RP Cable WU150 REV 00 15 05 2013 14 WUNDER SA BI SRL USER MANUAL 17 1 HOW TO USE YOUR PRINTER Connect the AC Adaptor and RS232 interface cable Press the I O button to power on the printer The PRINTER XL printer can be connected via the RS232 port and cable with the RA200 XL Press the PRINT key Print double language CHANGING THE PAPER ROLL The paper print roll on a PRINTER XL printer is changed as follows 1 Open the upper cover and position the paper roll so that it 2 Feed the end
2. of the paper roll through the printer cover and feeds in the right direction close the cover The printer is ready to print a Paper roll RA RP Cable WU150 REV 00 15 05 2013 15 WUNDER SA BI SRL USER MANUAL 17 2 PRINTER SPECIFICATION Max paper thickness um Paper 57 5 0 5 mm W x y30mm max Operating temperature Operating humidity 20 to 85 no condensation Conform to RS232 Voltage range adaptor only 12V 2A SHOCK HAZARD WARNING The printer and power supply should never be operated in a location where either one can get wet Personal injury could result MEDIA WARNING Always use high quality approved paper print roll The approved product can be ordered from your dealer RELOADING HINT If printer runs out of paper roll while printing switch the power off and reload paper roll Power on and print again HEO pOr Cee Ows RA RP Cable WU150 REV 00 15 05 2013 16 WUNDER SA BI SRL USER MANUAL 17 3 ERROR MESSAGES Problem Solution or Reason Status Indicator does not light when power Check the power connections from AC outlet to the printer power supply switch is turned to ON I position Status indicator illuminated green light but Check interface cable connections from the scale to printer the printer will not print Make sure the top cover is closed and locked Printer paper jammed Reset the paper roll Please refer to CHANGING THE PAPER ROLL Paper roll is
3. out Reload a new source of paper roll so the printer can continue printing Please refer to CHANGING THE PAPER ROLL Status Indicator is flashing green HO pOr Cee Ows RA RP Cable WU150 REV 00 15 05 2013 17
4. ACTION Low Battery This warnins shows that the voltage of battery is too low to use Please replace a new battery or plus the AC adaptor for operation Overload The total load exceeds the maximum capacity of scale Please reduce the loading and try again Counting error too high Indicates that the signal from the load cell s is too height Counting error too low Indicates that the signal from the load cell s is too low This error is normally caused by a serious fault on the scales such asa faulty load cell or wiring Please contact the local service representative This error is normally caused by a serious fault on the scales such asa faulty load cell or wiring Please contact the local service representative Zero count over calibration zero range 10 while power on Please re calibrate the instrument Zero count under calibration zero range 10 c while power on Please re calibrate the instrument EEPROM Error Indicates that there is a fault with the scales software RA RP Cable WU150 REV 00 15 05 2013 This error is normally caused by a serious fault on the scales such asa faulty load cell or wiring Please contact the local service representative WUNDER SA BI SRL USER MANUAL 11 MAINTENANCE AND ASSISTANCE For better and longer duration of the product it should receive thorough general cleaning periodically The instrume
5. NFORME ALLA DIRETTIVA 93 42 CEE CE 0470 RA RP Cable WU150 REV 00 15 05 2013 10 WUNDER SA BI SRL USER MANUAL 14 SCRAPPING AND WASTE DISPOSAL If set aside for a long period protect those parts which could be damaged due to dust build up Scrapping When you decide to no longer use this item we recommend making it unusable We also recommend making those parts which could be sources of danger harmless Waste doed EU 2002 96 EC This product complies with the EU Directive 2002 96 EC The symbol of the crossed out waste bin on the appliance indicates that the product needing to be treated separately from household waste at the end of its useful life must be completed in a separate collection facility for electric and electronic appliances or returned to the dealer upon purchase of a new equivalent appliance The user is responsible for bringing the appliance to an appropriate collection structure at the end of its life Appropriate separate collection and sending the appliance for recycling treatment and environmentally compatible waste disposal contributes to avoid possible negative effects on the environment and health and favours the recycling of the materials the product is made of For more detailed information regarding available collection systems contact your local waste disposal service or the shop where the product was purchased As consumers you are obliged by law to return used or dead batteries You may deposit old batteries
6. WUNDER SA BI SRL USER MANUAL SJ LZ US www wunder it PROFESSIONAL ELETTRONIC MDD SCALE MOD RA RP cable USER MANUAL E n ni M GD DA Read this manual carefully before using the instrument INDEX 2 GENEP AET ULES osnnetd rare PAGE 2 3 O PAGE 3 4 TECHNICAL PEC TATTOO seca settee ents octanos PAGE 3 5 ISSN PT LO PPM NE E N E ECO PE CO OE O PAGE 4 6 EA ON ee E A E O E A e e PAGE 5 7 MOTRU to al U Pe UP o Un O EE PAGE 6 8 PRINTER FONG O PAGE 8 9 1 e i A uE sentences aaa etna han ete teats ata ts naa tele aatae PAGE 9 10 PRROR NESA GE ccoo PAGE 9 11 ANT ERANG E ANDA SISTANCE a E papada osito PAGE 10 12 PP o O R aes peeu tne ada valle E PAGE 10 13 DENEA T GADE open acontece abro PAGE 10 14 a EP UU o UE oO TA PAGE 11 15 are O SP CO OO O ties bn nin det deat E E E arctan fade PAGE 11 16 ASSEMBLY USE MECHANICAL TELESCOPIC HEIGHT METER OPTIONAL Joc once PAGE 12 17 PPP UE OO A PAGE 14 RA RP Cable WU150 REV 00 15 05 2013 1 WUNDER SA BI SRL USER MANUAL By choosing the WUNDER mod RA or RP cable professional electronic scale you have purchased a high precision instrument Since over 40 years WUNDER has placed its experience at the service of health This instrument is compliant with national standards in hospitals and clinics with medical class I with measurement function and is calibrated in conformity with accuracy class Ill The instrument is characterised by the possibility of fixing the
7. at public collection spots in your town or else with any battery dealer who has placed specific collectors for this purpose Even when scrapping electric and electronic appliances they must be removed and deposited in specific collectors NOTE The following symbols indicate the presence of harmful substances Pb Pb batteries containing Lead Cd Cd batteries containing Cadmium Hg Hg Batteries containing Mercury A ATTENTION Do not throw electric parts and used batteries away with household waste Dispose of the batteries by means of your closest collection centres 15 WARRANTY This certificate must be kept until the warranty has expired It must be presented together with the invoice tax receipt or delivery note providing the name of the dealer and date of purchase whenever a technical intervention is required Otherwise the user will lose any warranty rights The warranty takes effect from the date of purchase and is valid during the entire period foreseen by the current catalogue pricelist By warranty we mean the replacement or repair free of charge of parts making up the appliance which at the discretion of the manufacturer are deemed faulty from the origin Wunder therefore has the faculty of repairing or replacing the item The warranty does not cover e shipping faults damage caused by falls carelessness or tampering e damage caused by incapability of using the appliance and of its improper use e damage caused by an insufficient or ina
8. class III Data length 8 bits Data code ASCII ES Serial RS232 En E PIN 5 o B a B Of 0 Bo PIN E Connector RS232 Connecting with PC Start Hyper Terminal Start Hyper Terminal program from clicking Start Menu Programs Accessories Communication Hyper Terminal New Connection Description Give new connection a name then click OK Select Your COM Port Click Connect to select your COM port Usually there s only one option for select Then click OK Port Settings Click Bits per second to set up rate at 9600 Data bits at 8 Parity at None Stop bits at 1 and Flow control at Hardware Then click OK to complete your setting Output Data When press the PRINT key to output data from scale to PC or an Optional Printer RA RP Cable WU150 REV 00 15 05 2013 8 WUNDER SA BI SRL 9 SETTING SETUP Switch ON the scale and long press AUTO OFF TIME SETUP This enables operator to select the auto turn OFF time of the device BUZZER ON OFF SETUP This enables operator to select beep sound ON OFF TARA Press 3 seconds HOI SELUP ADFF gt BD 5 gt 240 S UFF 2I 5 HOLA HO burr gt Un End End I a Note To confirm the settings please press CM when 10 ERROR MESSAGE REASON ERROR MESSAGE USER MANUAL 4 key for 3 seconds first SETUP and then A OFF will display successively 300 5 displays on the display
9. ctly set Time programming Use the number keys to enter the correct value press HOLD to confirm the entered date and time once correctly set 008 V Display format YYYY MM DD HH MM RA RP Cable WU150 REV 00 15 05 2013 6 WUNDER SA BI SRL USER MANUAL 7 3 HOLD FUNCTION The Hold function is used to accurately determine the average weight also with unstable value small movements switch on the scale using the ON OFF key The display shows 0 0 kg and the stable weight and zero indications after the self test Ask the patient to climb onto the weighing platform Press HOLD The display shows HOLD with a flashing triangle and then after a few seconds the average weight value that remains permanently on Press HOLD again to release the weight memorised on the display The instrument goes back to normal weighing mode The HOLD function may be activated before or after the patient has climbed onto the platform 7 4 BMI FUNCTION Press BMI in weighing mode The secondary display shows the last set height with the left digit flashing Use the number keypad to enter the height e g 170 cm Confirm with 2 Press HOLD to lock the value Climb onto the weighing platform when the display shows HOLD and weigh yourself The scale shows the weight height and BMI index Press BMI again to release the memorised weight and go back to normal operation mode 7 5 TARE FUNCTION Thi
10. dequate electrical system or alterations resulting from environmental climatic or other types of conditions e damage due to incorrect installation of the appliance and repairs carried out by unauthorised personnel e Interventions at home for convenience controls or presumed defects e Routine maintenance and that which can be considered normal wear from use e consumables such as power supplies batteries keyboards plates wheels heads rolls load cells faulty due to blows or overloads Service can also be refused when the appliance has been changed or transformed in any way RA RP Cable WU150 REV 00 15 05 2013 11 WUNDER SA BI SRL USER MANUAL In case of interventions at one s home the customer must pay the fixed fee if however the appliance is repaired at an authorised Wunder Service Centre expenses and relative travel risk are borne by the user Wunder will not be held liable for damage of any nature caused directly or indirectly to persons animals or objects resulting from failure to comply with all the instructions indicated in this manual or anyway resulting from improper use The Court of Bergamo has jurisdiction in case of any dispute 16 ASSEMBLY USE MECHANICAL TELESCOPIC HEIGHT METER OPTIONAL A ATTENTION ONLY FOR COLUMN SCALE HEIGHT ROD KIT 1 Metal support for elescopic height meter side view metal support 2 Black abs support height meter D ay E 3 Screws N 02 screws T E N 02 slotted screws
11. econd LCD automatically calculates BMI 4 Main LCD Weight 5 Power display On Off key Pressed for 3 seconds it switches off the scale Indication reset within 2 of the capacity HOLD Lock of displayed weight determination of the stable weight value RA RP Cable WU150 REV 00 15 05 2013 4 WUNDER SA BI SRL USER MANUAL Display Functions Net weight Weight stable Indicates the weight is stable Weight stable HOLD Function Weight Weight negative Indicates weight below zero 3 A Zero Indicates zero weight oe lt Flat battery Indicates the need to recharge or replace the battery Weight negative lt F ee Zero Flat battery 6 INSTALLATION A ATTENTION AFTER HAVING VERIFIED THE INTEGRITY OF THE EQUIPMENT AND OF ALL ITS COMPONENTS CONNECT THE INSTRUMENT WITH THE SUPPLIED POWER SUPPLY TO CORRECTLY RECHARGE THE BATTERIES Position the instrument on a level and stable surface The instrument must be placed away from heat sources in an environment without excessive vibrations and drafts Assembly for column version only Figure A Assembly is easy fix scale s column to the weighing platform See Figure A A ATTENTION FOLLOW THE INDICATIONS BELOW BEFORE INSERTING THE COLUMN Overturn the weighing platform resting it onto a level surface Remove the display connector from inside the column and connect it to the weighing Figure B Figure C platform connector making it pass throu
12. electronic terminal to the weighing platform by means of a column or else installing the terminal autonomously The instrument is equipped with a dual LCD electronic terminal with triple reading to simultaneously view Weight Height and BMI 2 GENERAL RULES A Carefully read this manual before using the instrument as it supplies important indications concerning OPERATING SAFETY AND MAINTENANCE The descriptions and illustrations supplied in this manual are not binding WUNDER reserves the right to modify its products as deemed convenient in order to approve them without being committed to update this publication Conventions The following symbols have been used in this manual 0470 MEDICAL CERTIFICATION METROLOGICAL CERTIFICATION AND APPROVAL FOR MEDICAL USE SEA ACCURACY CLASS ASSISTANCE WARRANTY CERTIFICATE ATTENTION PLACED BEFORE DETERMINING PROCEDURES COMPLIANCE FAILURE CAN DAMAGE THE PRODUCT WARNING PLACED BEFORE DETERMINING PROCEDURES COMPLIANCE FAILURE CAN HARM THE OPERATOR OR PATIENT OR DAMAGE THE PRODUCT TYPE B PARTS SUPPLIED X WASTE DISPOSAL i BATTERY POWER v INDICATION OF WEIGHT FUNCTIONALITY INDICATION OF STABLE WEIGHT 9 INTERFERENCE COULD OCCUR NEAR THE APPLIANCES Ol DUAL INSULATION RA RP Cable WU150 REV 00 15 05 2013 2 WUNDER SA BI SRL 3 SAFETY A WARNINGS USER MANUAL Operators must read this manual carefully comply with the instructions it contains and become familiar wi
13. gh the hole indicated by the red arrow see Figure B Fix the column to the weighing platform support using the 4 supplied screws see Figure C Position the instrument on the floor and adjust the 5 feet to it To use connect the supplied external power supply to the current see battery operation RA RP Cable WU150 REV 00 15 05 2013 5 WUNDER SA BI SRL USER MANUAL 7 INSTRUCTION FOR USE 7 1 Instruction for charging and connecting If prompt displays on the LCD please charge the scale with exclusive adaptor Locate adaptor plug on the rear side of indicator The battery should be recharged at least every 3 months regardless if it is used or not After a long period in storage e g over 3 months the battery should run a full cycle charge discharge to allow it to restore to full capacity NU Ac Jack connector 7 1a Rechargeable Batteries 1 Open the battery cover and take the battery out 2 Disconnect the rechargeable battery pack then replace it by a new one Put the battery back then arrange the connector in place well 7 2 DATE AND TIME SETTING Keep the HOLD key pressed for 3 seconds to access TIME SETTING programming Example to program 25 December 2008 8 00 a m Year programming use the number keys to enter the correct value press HOLD to access the next step once correctly set Date programming Use the number keys to enter the correct value press HOLD to access the next step once corre
14. nt must be cleaned with a soft cloth moistened with water or neutral detergent without using solvents or abrasive substances If the instrument remains idle for a long period remove the batteries from the terminal During shipping make sure not to subject the instrument to blows or excessive mechanical stress In case of repairs or assistance contact your dealer or an authorised service centre contacting service2 wunder it or sales wunder it 12 CONFORMITY WUNDER MODEL RA or RP CABLE ELECTRONIC SCALE SERIAL N We hereby certify that this instrument has been inspected and has successfully passed the functional test Itcomplies with the following standards and directives EN 45501 EN60601 1 2 EN60601 1 93 42 EEC Medical Devices Directive 13 IDENTIFICATION LABELS WUNDER SABI srl DK 0199 336 Max 300 kg RA WU 150 Qi amp 1009 Matr 0021 50 350 Temperatura di stoccaggio 0 60 C Storage Conditions Temperature 0 60 C RA RP stoccaggio RA VANO BATTERIE Per la sostituzione della batteria modello ricaricabile tipo RETC 7 2 V 2000 mAh vedere il manuale di istruzioni To replace the battery rechargeable sealed type RETC 7 2 V 2000 mAh see the manual RA VANO BATTERIE Per la sostituzione della batteria modello ricaricabile tipo RETC 7 2 V 2000 mAh vedere il manuale di istruzioni To replace the battery rechargeable sealed type RETC 7 2 V 2000 mAh see the manual CO
15. s function allows displaying two weights Switch on the instrument using the key CO 10 When the display indicates 00 0 and a beep is emitted position the objects clothing constituting the tare onto the weighing platform AN 40 With the weight stable and the appearance of the stable symbol circle press 2 and the display shows 00 0 _Ask the patient to climb onto the platform The indicated weight represents the tare s net value Delete the memorised tare value by climbing down from the instrument and press tana ul E A again RA RP Cable WU150 REV 00 15 05 2013 7 WUNDER SA BI SRL USER MANUAL 8 PRINTER FUNCTIONS Weight can be printed for records using RS232 interface cable After weighing simply press PRINT key to print out the results The format presented below is the standard format of results print out and cannot be changed More informations info wunder it or service wunder it WUNDER Set parameters of the scale interface on the connected device It is not possible to change the scale Date Month Year hour minute Peso Weight 30 00kg para meters Altezza Height 100 0cm Indice Massa Corporea 30 0 BMI Body Mass Index Baud rate 9600 bps Sottopeso Parity check None Underweight lt 18 Normopeso Normal weight 18 24 9 Sovrappeso Pre obesity 25 29 9 Stop bit 1 bit Obesita calaae I ObesityclassI________30 349 Handshake RTS CTS Obesita calaae II Obesity class II Obesita calaae III Obesity
16. th the correct use and maintenance procedures of the instrument e Retain this manual for consultation and as a help in staff training e Do not overload the instrument beyond its maximum capacity e Do not apply loads abruptly e Do not press the keys with sharp or pointed objects e Do not try to open the instrument e Do not remove seals from the instrument e Do not short circuit the battery terminals e Use only the power supply provided by Wunder Before using it make sure that the local mains voltage is compatible with the voltage of the adapter shown on the identification plate e Regularly check the integrity of the instrument s power cord and make sure it does not come in contact with hot appliances e Make sure that the power cord does not create obstruction hazards e Unplug the instrument before cleaning it e Do not place the instrument in water or other liquids e Perform maintenance and subsequent metric verifications regularly 4 THECHNICAL SPECIFICATION Model RA200 300 Capacity 200 300 kg Division 50 100 g MDD OIML Class Ill Unit weight kg Display LCD 1 con 5 digits attivi with 18 key pannel Function Key Power Operation temperature ON ZERO OFF HOLD BMI TARA PRINT Rechargeable Batteries Pack Adapter 12 V 2A da 5 C a 35 C RA RP Cable WU150 REV 00 15 05 2013 3 WUNDER SA BI SRL USER MANUAL 5 INDICATOR 1 Key function 2 Weighing capacity and division 3 S
Download Pdf Manuals
Related Search
Related Contents
MEDI User Manual SPYPEN IUNO UM GER.indd Manuale di installazione Targus CN317 Model: HIT-3 USER`S MANUAL - Hoffer Flow Controls, Inc Manual - Test Equipment Depot Eizo CS240-BK Philips 046677415686 energy-saving lamp S-Class Copyright © All rights reserved.
Failed to retrieve file