Home
User manual_Store_EN - Badger Meter Europa GmbH
Contents
1. gt Badger Meter Europa GmbH ModMAG M2000 Store Restore INSTALLATION AND OPERATION MANUAL April 2013 MID M2000 BA Store 02 1304 Contents Page 1 Basic safety Precaulions nennen 1 2 Mp isa 2 3 Description anna 2 4 aran 2 A T 2 5 1 Storing configuration to a token en 4 5 2 Restoring configuration of a meter from the 4 6 Store Restore and Security co ede 5 6 1 Storing to a token with a secured Meter 5 6 2 Restoring a secured Mii dnadmin 5 6 3 Restoring an unsecured 5 TTroUubleshootung kusudmirarmreuge eg SBFORBETEBRERFIEFEENETEETEILTERTREENEESETTERFLRERFTELENTFLEE 6 8 Return of goods for repair harmlessness declaration rnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnr 7 Basic safety precautions Page 1 7 1 Basic safety precautions Before installing or using this product please read this instruction manual thoroughly Only qualified personnel should install and or repair this product If a fault appears contact your distributor Installation Do not place any unit on an unstable surface that may allow it to fall Never place the units above a radiator or heating unit Route all cabling away from potential hazards Isolate from the mains before removing any covers Power con
2. O dangerous toxic etc Security specifications are attached Signature of person in charge Name of the person in charge in capital letters Date Company stamp gt MID_M2000_BA_Store_02_1304 Hotline Phone 49 7025 9208 0 or 30 Fax 49 7025 9208 15 Badger Meter Europa GmbH Subsidiary of Badger Meter Inc USA N rtinger Strasse 76 72639 Neuffen Germany E mail badger badgermeter de www badgermeter de
3. token is corrupted Token must be reprogrammed Parameter on token does not exist in meter Can be ignored if programming a meter with older firmware MID_M2000_BA_Store_02_1304 Return of goods harmless declaration Page 7 7 8 Return of goods for repair harmlessness declaration Please copy fill in and sign hereafter harmlessness declaration and enclose it for any return of goods you may send back for repair No repair will be performed prior to receiving the harmlessness declaration duly filled and signed Harmlessness declaration To Attn From Dept Please note that no repair will be performed prior to receiving of this declaration duly signed by you Please send all parts clean from medium and inform us about possible medium wastes remaining in the part For this purpose please use this form A security specification sheet of the medium must accompany this declaration in the following cases Toxical dangerous or objectionable media or media belonging to any dangerous materials class We inform you that uncleaned parts lead to additional costs Extra clean costs will be charged to you Furthermore we reserve us the right to send the parts back to you for cleaning Declaration We herewith confirm that the part s sent for repair has have been cleaned and is are free of any liquid and or solid wastes of the medium and or cleaning medium Any eventually remaining wastes are O harmless
4. complete During this time a status dialog window displays Once the status dialog window is no longer displayed remove the token Label the token for future use 5 2 Restoring configuration of a meter from the token PD Insert the token If the token is configured for power on load reset the meter with the reset button on the electronics After the meter has been reset for 10 seconds proceed to Step 6 Navigate to the Advanced gt Restore from token menu Move the arrow to Confirm and press E Move the arrow to Exit with save and press E Exit the main menu by navigating back to the home display flow rate totalizer display This step is important because it copies the restored volatile configuration to non volatile memory EEPROM Power cycles or resets that occur before this step is completed will invalidate the restore request The power cycles or resets must be performed again Remove the token gt MID_M2000_BA_Store_02_1304 Store Restore and security Page 5 7 6 Store Restore and security Security must also be considered when using the Store Restore feature Tokens can be used to secure meters However updating a secured meter with contents on a memory token requires extra consideration 6 1 Storing to a token with a secured meter During the store to token operation the token is created and the admin level pin is saved to the token The admin level pin is recorded on the token regard
5. ettings Non transferable parameters include Serial number Excitation frequency Scale factor Analog output calibration factors including custom offsets The parameter selection submenu allows the operator to choose the groups of parameters to be stored to the token Currently there are six groups as identified by the submenu The table below defines each group Menu designation Group description Group 0 ALL All meter parameters are stored to the token Group 1 USER Only user parameters are stored to token Group 2 PRV Reserved Group 3 FACT Only detector calibration parameters are stored to the token Group 4 PRT A Only Port A communication parameters are stored to the token Group 5 PRT B Only Port B communication parameters are stored to the token Group 6 SEC Only security pins are stored to the token The amplifier calibration parameters are specific to each amplifier and are not allowed to be copied from one meter to the next gt MID_M2000_BA_Store_02_1304 Operation Page 4 7 5 1 Storing configuration to a token Insert the token Navigate to the Advanced gt Token copy menu and configure the token properties and group selections Navigate to the Advanced gt Store to token menu Move the arrow to Confirm and press E Move the arrow to Exit with save and press E The token copy process may take up to 30 seconds to
6. less of the Group 6 SEC parameter selection The recorded pin is not restored to the meter but is verified when the token is used to update secured meters with the power on load feature 6 2 Restoring a secured meter Restoring a secured meter with the contents of the memory token requires the operator to login with the Admin level pin in order to gain access to the token configuration menus The group 6 SEC security pins on the token will overwrite the security pins on the meter if they are different The power on load feature of the memory token requires the admin level pin of the token to match the admin level pin of the meter otherwise the power on load restore operation will not be successful The admin level pin stored to the token is the same admin pin of the meter used to create the token 6 3 Restoring an unsecured meter Restoring an unsecured meter has no limitations However it is important to consider the security pins residing in the token In this case the unsecured meter can become secured with the pins residing in the token The pins residing in the token should be recorded and associated with the programmed token If the pins of the token are unknown it is recommended to immediately navigate to the security menu and record the pins An alternate option is to create a token that does not contain security pins like Group 6 SEC This will allow programming an unsecured meter with a token generated by a secured meter lea
7. nection Use only the type of power source suitable for electronic equipment If in doubt contact your distributor Ensure that any power cables are of a sufficiently high current rating All units must be earthed to eliminate risk of electric shock Failure to properly earth a unit may cause damage to that unit or data stored within it Protection class The device has protection class IP 67 and needs to be protected against dripping water water oils etc Setup amp operation Adjust only those controls that are covered by the operating instructions Improper adjustment of other controls may result in damage incorrect operation or loss of data Cleaning Switch off all units and isolate from mains before cleaning Clean using a damp cloth Do not use liquid or aerosol cleaners Repair of faults Disconnect all units from power supply and have it repaired by a qualified service person if any of the following occurs e If any power cord or plug is damaged or frayed If a unit does not operate normally when operating instructions are followed If a unit exposed to rain water or if any liquid has been spilled into it If a unit has been dropped or damaged If a unit shows a change in performance indicating a need for service A WARNING Failure to adhere to these safety instructions may result in damage to the product or serious bodily injury RoHs Our products are RoHs compliant gt MID M2000 BA Store 02 1304 Impor
8. tant Description Performance Operation Page 2 7 2 Important The Store Restore feature requires firmware version 1 11 or later Reference Badger Meter P N 67354 003 to obtain a firmware upgrade kit 3 Description The Store Restore feature is intended to save installation costs and reduce installation time This feature is also intended to protect meter configuration and assure the operator that the meter is properly configured Over time and handling of the meter the meter configuration could change The Store Restore feature allows the meter to be quickly set to the operator s original configuration 4 Performance The Store Restore feature provides the ability to save meter configuration to a memory token The memory token can be placed into alternate meters so that each meter in the system has the same configuration The memory token can also be stored in a safe place and later used to restore meter configuration if the configuration of the meter is in question The operator has the option to select which groups of configuration parameters are stored to the memory token providing additional flexibility for system installation 5 Operation The means to enable and configure the Store Restore feature are found under the Advanced menu of the menu manager located in the Token Copy submenu The menu items of Token Copy are e Configuration Token Properties Parameter Selection e Store
9. to Token e Restore to Token The Configuration submenu allows the operator to configure token properties and select the groups of parameters that are to be stored to the token Token properties and the parameter selection configurations should be configured first prior to copying meter information to the memory token Token properties allow the token to be configured in a way that the behavior of the token can be defined Such properties include Write protect protects the token from being overwritten e Power on load requests the meter to load the contents of the token into the meter at power on e One time load requests the meter to erase the token after the contents of the token have been stored to the meter gt MID_M2000_BA_Store_02_1304 Operation Page 3 7 Write protect cannot be undone by the operator Caution should be used when configuring the token for writeprotect mode The chart below lists the categories of parameters that can be individually selected for storing to the memory token Parameter categories Calibration Pipe diameter Detector factor Detector offset Interface for port A only Communication port A B Node address Baud rate Parity Date bits Stop bits Extended node address for port B Profibus DP only Admin PIN Securit 7 Service PIN User PIN All other meter parameters including measurement and User I O s
10. ving the unsecured meter unsecured gt MID_M2000_BA_Store_02_1304 Troubleshooting 7 Troubleshooting Page 6 7 Display message Description Recommended action Token not supported Token is not supported Token is previously formatted for an alternate feature for instance data logging New token is required Token not inserted Token operation cannot be performed because no memory token is detected Please ensure the memory token is seated firmly into the socket located on amplifier Token is protected Token is write protected Reprogramming the token is not allowed Token must be replaced or reinitialized Reinitializing token requies special access over ModBus contact tech support for details Token is corrupted Bad checksum found within the Token is not usable in current state operator must follow steps to re program the token Symptom Recommended action ring power on load Meter is not being restored with contents on token du manually re enable security If meter is secured unsecure the meter then retry the restore operation The restore operation will re enable security only if the security pins are stored to the token Otherwise operator must with contents Meter is not being restored Ensure meter firmware is at firmware revision v1 11 or later in the error list 3 Token errors are reported Parameter stored in