Contents
1. and then the Stop button 7 RE USING THE SPY USB To re use the SPY USB it must be in OFF mode Plug in the SPY USB Once the software is opened click the Fad icon if you want to change the configuration or a click the icon and choose the start mode as described in paragraph 4 Then click the Start button the blank box in the lower left hand corner will turn green and say Passed 8 CUSTOMER SUPPORT If you need help with the software installation or troubleshooting issues you can contact us on 33 3 63 15 80 07 or by email support jri fr We can also install the software remotely if necessary JRI SPY USB Page 4
2. recorder off prior to its intended use Click OK to validate The new configuration will now appear in the Custom section and can be used with your other SPY USB recorders without modification Then click on Configure to upload it to the recorder the blank box in the lower left hand corner will turn green and say Passed JRI SPY USB Page 2 SPY USB NA QUICK START GUIDE 4 TURNING THE SPY USB ON Click the 7 s icon to choose the Start Mode and turn on the recorder x E Tag Management co drop down box Tag ID 300006001 8 UC Tag Mode Off Max Tracking Time 1095 Days 0 Hours 0 Minutes Max Logging Time 2 Days 18 Hours 40 Minutes Soaking Countdown 1 Minute Remaining Tag Life 1007 Days 2 Hours 40 Minutes Use Count Remaining 24 ES pkation Date 2018 09 03 1718 Days Remaining If the Start Mode selected in paragraph 2 Cura a doesn t suit you you can change here by oe en selecting one of the 3 options from the Cancel Start Tag Immediately at Auto Sleep Time after Auto Record Time You will also need to select how to turn off the recorder Cancel Once you have selected your settings click Start and the box in the lower left hand corner will turn green and say Passed If you choose to turn the SPY USB on by using the button follow the instructions below SPY 8 US ir IM 01234567890 ALO aH
3. Automatic Log Download Never Manual Always Only on Excursion C Never Manual Always Only on Excursion Start Mode Immediate with Tag Button Press J at Auto Awake Time i A A Start Mode Immediately with Tag Button Press at Auto Awake Time In the Export section choose the PDF tab Select Images First and Append Log Data Points In the Spreadsheet tab select Display with External Viewer after Export Click Apply and then OK to validate the changes m Options Options Display PDF Spreadsheet Display PDF Spreadsheet XML Email Alert ccess Restriction 2 ccess Restriction acing PDF Export Options Reader Custom Title 45 Chars C Custom Logo Image 2 00 5 in Browse Default Report Save Location C Users hlorentzen D ocuments Log ic Reports Browse Default V Images First V Append Log Data Points mail Alert Address CSV Export Options V Display with External Viewer after Export I Auto Send PDF Report with FTT Address Cancel Apply Cancel Apply JRI SPY USB Page 1 SPY USB any QUICK START GUIDE 3 CONFIGURING THE SPY USB E Wi El Tag Management bu Click the icon to display the configuration interface Name HwWL2 Product Version Logic x2 Soaking Countdown 2 Minutes Logging Interval 2 Min
4. SPY USB may QUICK START GUIDE 1 SOFTWARE INSTALLATION The SPY soft can be downloaded and installed from www jri maxant com Once installed plug the SPY USB into your computer AutoPlay Windows will automatically install the USB drivers this may take a couple of minutes and then the following window will appear se RFID Tag Device Select Always do this for this device View RFID Tag Contents using SPY Soft Select View RFID Tag Contents as a default option Generate RFID Tag PDF Reports PD using SPY Soft PDF View more Autoplay options in Control Panel 2 SOFTWARE CONFIGURATION From the Tools menu select Options Select a language from the drop down menu and click Apply Select C or F the correct time zone Combined Curve Block Start Mode and then click OK OS Sl oon a an 7 Language Export ccess Restriction Reader Export ccess Restriction EN English Reader WW Europe Standard Time Brussels Berlin Bern Rome Stockholm Vienna 01 00 Browse Curve C Show Curve Only Block Oni Combined Curve Block C Show Curve Only Block Only Combined Curve Block M Duration Time Axis Enabled by Default Duration Time Axis Enabled by Default F MKT Enabled by Default I MKT Enabled by Default Histogram Histogram I Log Scale Enabled by Default I Log Scale Enabled by Default Automatic Log Download
5. o O ACTIVI Press the ON OFF button to the left near the USB port for 3 seconds The ACTIVE Led light in the middle will blink slowly twice to confirm the command If the soaking countdown has been set to 10 minutes recording will start 10 min after having pressed the ON button and the ON button is pressed again during this period the soaking countdown will start all over again This prevents turning the recorder off prior to its intended use JRI SPY USB Page 3 SPY USB way QUICK START GUIDE 5 READING AND SAVING DATA Once the SPY USB is plugged into the USB port the user interface is displayed automatically M JsPv use r amp lS m Overview Curve Histogram Pie Chart Excursion Info Set up History Tag Alerts 3000060013 LRT 26 3 C Max 27 1 C Mode Recording Status Check Record Time 2 Days 22 Hours 59 Minutes Time 2013 12 09 15 41 40 Browse through the different tabs to see the details of the curve and the temperature excursions D PDH Click the PDF icon to generate a PDF report click Show details if you wish to customize it S cs Click the CSV icon to generate an Excel document L_U Click this icon to save your data and name your file 6 TURNING THE SPY USB OFF To turn off the SPY USB press the ON OFF button to the left for 3 seconds Or plug it into your PC and click the 4 icon
6. time cumulative 2o Minutes Single le Solid F Unlimited T 2A Status Select either Solid Blink or None m SLL to determine how the Led lights on the SPY USB will display visible after pressing the STATUS button on the Oe Max Count This function is currently not active ia Stop Excursion Filter allows to ignore temperature excursions X minutes before manual shutdown Off Excursions Temp Trigger Type went Status Max Count Add Remove Min i Stop Excursion Filter miri i Y W Enable Blink On Excursion Timing by default Logging Interval min 2 x Soaking Countdown min 2 _ Enable Blink on Excursion Selecting this box will constraints HH cause the Leds Hi amp Lo to blink without pressing the Max Logging Time 5 Days 13 Hours 20 Minutes recorder s STATUS button To discern what type of Max Tracking Time 1095 Days 0 Hours 0 Minutes alarm has occurred press the STATUS button Max Excursion Count Timing Logging Interval Choose the interval time from the drop down box The Max Logging Time below will show you the total amount of time the SPY USB will record Soaking Countdown Start delay when turned on If the soaking countdown has been set to 10 minutes recording will start 10 min after having pressed the ON button and the ON button is pressed again during this period the countdown will start all over again This prevents turning the
7. utes Max Tracking Time 1095 Days 0 Hours 0 Minut Max Logging Time 5 Days 13 Hours 20 Minute Max Excursion Count 48 Blink On Excursion Enabled Excursions Stop Excursion Filter 1 Minute Type Temperature Trigger Type Event Status Max Count High 30 0 C 2 0 Minutes Single Solid Unlimited High 25 0 C 2 0 Minutes Single Solid Unlimited Low 5 0 C 2 0 Minutes Single Solid Unlimited Low 0 0 C 2 0 Minutes Single Solid Unlimited You can choose from one of the preset configurations or create you own by clicking Add Name Custom HWwL3 Bin Dividers 50 45 40 35 30 25 20 15 11 10 9 8 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 11 218 14 18 18 1718 18 38 25 40 98 a 4B Add Edit Delete 50 55 60 65 70 75 80 C Configure Cancel E d gt Build New Configuration Name Enter a specific name for you configuration Build Configuration For SPY USB Excursions Mo ome Click to add a High or Low excursion limit Click to delete an excursion limit Temperature Enter the High and Low temperature that you do not wish to exceed Trigger Type Enter the amount of time that your product can be above the High temperature or below the Low temperature before triggering an excursion 2 Em Select Minutes Hours or Days 2 Jhi f Event choose if the trigger time should be calculated on a single occurrence single or a continuous amount of
Download Pdf Manuals
Related Search
Related Contents
OM, McCulloch, MAC 3-14 XT, MAC 4-18 XT, MAC 4 Manual de uso Secuenciador 003-2631-02 Guide de l`utilisateur Unité dentaire Elevance TNo.132/TB-1202 NSテーブル Service Manual Owner`s Manual - T@B Teardrop Trailers (PR) 2015年6月27&28日 香港オークション 落札結果速報 ASUS M3N78-CM User's Manual PN-L702B Operation-Manual ES Copyright © All rights reserved.