1. 2000 Jr Series S2000Jr 15 S2000Jr 30 52000 60 0 61b 0 002Ib 0 151b 0 0051b 0 301b 0 011b Ib 6 151 0 0051 15 301b 0 0011b 30 601b 0 021b CAPACITY 0 3kg 0 001kg 0 6kg 0 002kg 0 15kg 0 005kg 3 6kg 0 002kg 6 15kg 0 005kg 15 30kg 0 01kg DISPLAY VFD of LCD 5 6 6 Weight Unit Price Total Price SYMBOL ON DISPLAY Power Zero Tare Low Battery Backlight Ib kg Ib kg SAVE MAXIMUM TARE kg 5 998 kg 9 995 kg 29 99 kg MAXIMUM TARE Ib 2 999 Ib 5 998 Ib 9 995 Ib OPERATING TEMPERATURE 0 40 POWER SOURCE 120 60 Hz POWER CONSUMPTION Approximately VFD Type 10W LCD Type 5W PLATTER SIZE inch 119 7 W X 86 6 D PRODUCT SIZE inch 141 7 W X 137 7 D X 41 7 H MINIMUM VOLTAGE LEVEL OF THE BATTERY About 5 8V LCD only Battery is charged for 12 hours Battery Life LCD type only more than 120 hours backLight off Even it the battezy is fully charged the CHARGE lamp is still RED x lt Notice specifications are subject to change for improvement without notice MEMO
2. Press TARE key to set zero point SAVE ZERO NET lb kg a lb kg TARE Press TARE key again to set zero m Preset tare SAVE ZERO NET lb kg lb kg no pPress appropriate numeric keys 10 g SAVE ZERO NET lb kg b kg TARE Press TARE key to set zero Chapter 2 PLU Saving Calling up a Saving unit price on PLU This section explains how to save unit price in PLU Number of PLU Range Remarks PLU 199 1 199 PLU WIName Option 28 1 28 8 Characters PLU Number of direct PLU may be different on product model key is to clear data input 189 SAVE RU ZERO NET lb kg b kg pPress numeric key to input unit price you wish to have Ex 1 99 ZERO NET Ib Press MW key kg SAVE SAVE ZERO 916 S kg ZERO NET lb kg lIb kg Oe m pPress numeric key to input a PLU address Press MW key to save it Ex PLU 10 b Saving PLU name option If you have 28 PLU name inputting option you may save the name of PLU for 1 28 e key is to input save a character and move to next character or byte e ZERO key is to move previous character or byte key is to move next programming menu SAVE kg b kg ZERO NET m kg 41C50C50C 4 C alphabet C appropriat
3. b Sales using PLU Price Look Up Direct PLU 158 SAVE SAVE 200 188 a NET KO b kg ZERO NET lb kg EC b kg Call direct PLU Ex M1 SAVE ZERO NET lb kg kg RC Place an item on the platter Remove the item from the platter Indirect PLU SAVE SAVE ZEPO NET lb_ kg ZERO NET lb kg KO b kg Call up a indirect PLU Press 6 Key and Place an item on the platter M gt Key PLU 6 for Kiwi Remove the item from the platter to go back to normal weighing mode HIGH ORDER LOW ORDER 2 eetere tel ERROR MESSAGES Error Message Description Solution on Display Er 1 The 1 occurs when a current zero point Please call your CAS dealer has shifted from the last span calibration The 2 is not real error Only it prompts Please call your CAS dealer return CAL switch to the normal position Er 10 The Err 10 means a failure of the analog module Please call your CAS dealer fi Replace the analog module by a new one The Err 11 means a writing error of the Please call your CAS dealer Er 11 internal nonvolatile memory To recognize this error be sure to check the voltage on the circuit and do calibration procedures The Err 12 warns that the scale has lost the Please call your CAS dea
4. DESCRIPTION ZERO v Zero on NET w Tare on GO Backlight on Low battery warning Ib w lb mode on kg w kg mode on b w Ib mode on kg w kg mode on SAVE w Save on OPERATIONS Chapter 1 Basic Operation a Turning the scale on off SAVE ZERO NET Ts kg kg ON OFF Press ON OFF key to turn on SAVE ZERO NET Ib kg kg ON OFF Press ON OFF key to turn off b Turning the backlight on off option in LCD version only SAVE SAVE ZERO NET sib kg ON OFF Press ON OFF key for a few seconds under the backlight on c Zero function SAVE ZERO NET kg kg pPress ZERO key to set zero b kg ON OFF Press ON OFF key again under the backlight off d Tare function Tare means the weight of container You may use tare function when you weigh an item with container and measure only the weight of item One time tare SAVE ZERO NET lb kg b kg pPlace a container on the platter Ex 200 g of tare m Successive tare SAVE ZERO m kg gPlace another container on the platter Ex 100 g of tare SAVE ZERO NET lb kg kg After weighing item remove all of the container from the platter SAVE ZERO NET lb kg KO b kg Press TARE key to set zero point Ex 200 g of tare SAVE ZERO NET lb kg a kg TARE
5. explains how to set the auto power off function Options Description NO No auto power off 10 minutes Auto power off 10 minutes when no use 30 minutes Auto power off in 30 minutes when no use 60 minutes Auto power off in 60 minutes when no use SAVE ZERO NET lb kg KO b kg B Select a option you wish to have by using TARE key Ex 30 minuets b Ib kg mode selection This section explains how to set Ib kg Ib kg mode Functions Description Remarks 1 Ib Ib mode kg Ib convert key Disabie 2 kg kg mode convert key Disabie 3 Ib kg Ib kg mode convert key Enable Iz USE SAVE SAVE ZERO NET lb kg b kg ZERO lb kg aC kg pPress ZERO key to move next function Use TARE key to select KG mode setting LB KG mode Default LB mode SAVE ZERO NET lb kg KO kg 5 i Use TARE key to select LB KG mode c EL backlight ON OFF function option in LCD version only This section explains how to set backlight on amp off function and automatic off d Selecting the printer This section explains how to select the printer option when you d like to use the printer connected to 52000 Jr series function Options Description Remarks OFF Backlight OFF ON Backlight ON 3 Seconds Automatic backlight off when not in
6. Price Computing Scale 2000 Jr Series OWNER S MANUAL 900 ERS 0011 1 2006 05 PREFACE OVERALL VIEW ee eee 6 DISPLAY 6 KEYBOARD 7 INSTALLATIONS 8 OPERATIONS eener 11 Chapter 1 Basic Operation SK Aud CUR 11 Chapter 2 PLU Saving amp Calling up s 13 Chapter 3 User s Set up Modesta a ha 16 Chapter 4 Sales Transaction 20 ERROR MESSAGES vvii 23 Picture 2 Using Printer 24 SPECIFICATION 2 2 25 PRECAUTIONS Precautions when installing the scale To ersure that you get the most from your scale please follow these instruction Do not disassemble the scale When any damage or defect occurs contact your CAS authorized dealer immediately for proper repair Do not overload beyond the maximum weight limit Scale must be grounded to minimize electricity static This will minimize defect or electric shock ee SC Do not pull the plug by its cord when unplugging Damaged cord could cause electric shock or fire To prevent from fire occurring Do not place or use the scale near flammable or corrosive gas To reduce electric shock or incorrect reading Do not spill water on the scale or place it in humid condition Avoid placing the scale near heater or in direct sunlight Insert plug firmly to wall outlet to prevent electric shock Use proper Adapter Incorred adapter could da
7. e ASCII codes to save the PLU Press TARE key to exit to normal weighing name Ex APPLE is 4 1 C 5 0 C 5 0 mode or C key up to maximum 8th byte Then 4 C 4 5 automatically exit to normal weighing mode Please refer to Alphabetic key location c Calling up PLU Indirect PLU SAVE ZERO NET n kg ZERO NET KO b kg ic To call up indirect PLU saved To go back to normal weighing mode press appropriate numeric keys address and press C key gt key Ex PLU 10 Direct PLU M1 M3 SAVE L 0DU NET __049 kg 0 000 b To call up direct PLU saved just press appropriate direct PLU key Ex PLU 2 _ 280 kg To go back to normal weighing mode press C key Chapter 3 User s Set up Mode This section explains how to set up the following functions Functions Options Remarks 1 Auto power off NO 10 30 60 2 Ib kg mode selection Ib kg Ib kg When backlight option selected 3 EL Backlight ON OFF OFF 0 3 5 10 in LCD version only 4 Printer selection NON DLP 50 SAVE ZERO NET Ib kg aC lb kg _ mE Hold down ZERO key as press the ON OFF key e Press ZERO key to save current option and move to next function setting mode Press key to move to other next option a Auto power off This section
8. ler Err 12 parameters for weighing regulations or has lost the factors for a digital span calculation Err 13 The Err 13 means the soft key code is broken Please call your CAS dealer Help 1 Help 1 is marked in case of zero extent Please remove the item from the P exceeded platter Help 3 Help 3 is marked in case sale number of Spend again accumulated TTP gt times exceeds 99 value after delete Help 4 is marked in case Euro factor value is Input again Euro factor value 0 at Euro rate application Pay value than Total sale amount Help 4 Help 4 is maked when input smaller Pay cost than of money bigger value or same Total sale amount of money at Pay function use value input Help 5 Help 5 is marked when DTP number of times Spend again accumulated DTP E is more than 50000 times value after delete XT Overloaded Please remove the item form the a platter When total price exceeds 9999 99 this message Please input appropriate number is displayed with beep within maximum capacity on the display LobAt Battery voltage is too low Please plug in and recharge battery It occurs when user turns on the scale and it is Please move the scale to stable n in unstable environment envionment Picture 2 Using Printer SPECIHCATION Please connect your printer to RS 232 port which is located at the gray part on the picture using RS 232 Cable
9. mage the scale WARNING Make sure to plug your scale into the proper power outlet For maxinum perfomance duginipa power oufet 30ninuies before the usage for wamup Attention For consistent and accurate reading maintain periodical check by your CAS authorized dealer Avoid sudden shock to the scale Internal mechanism could be damaged Grab on the bottom of the scale when moving Do not hold by the platter Take the battery out when scale is not in use for long time Leakage from the batteries is hazardous Place the scale on firm and temperature consistent environment By adjusting 4 corners of the scale set the scale even using the built in scale leveling indicator Keep the scale away from other electromagnetic generating devices This may interfere with accurate reading Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instruction ALLY D Correct type of battery PREFACE Thank you for purchasing your CAS 52000 scale CAS scales are designed and produced under rigid quality control to deliver outstanding performance reliability and long life This manual will help you with the proper operation and care of your new CAS 52000 Please review the S2000Jr scale manual before you use the scale and keep it handy for future reference E DISPLAY amp KEYBOARD LCD STANDARD TYPE Frort Dis
10. play LCD POLE TYPE Front Rear Display CAS MODEL S2000 Jr TOTAL PRICE s Bana WEIGHT UNIT PRICE B ZERO b kg LCD STANDARD TYPE Rear Display WEIGHT T EE PRICE E TOTAL PRICE ZERO b kg m EE s SAVE VFD STANDARD TYPE Front Display VFD POLE TYPE Front Rear Display ees WEIGHT UNIT PRICE ZERO NET 0 w b g VFD STANDARD TYPE Rear Display DEN gt UNIT TOTAL ZERO kg 1 es b kg SAVE a Table Key Functions m2 oo To input all of numerical data 9 ex Direct PLU keys To clear data 4 5 B To save PLU 1 2 3 Le To call up PLU To set zero T m gt set or clear tare value 2 m To turn on amp off the scale or backlight LCD version only m INSTALLATIONS lt gt amp m Used to prevent the auto clearing of unit price and weight both 1 Insert the post pipe into a post bracket as Fig 1 kg lb Used to convert a kilogram and pound 2 Insert and fasten two display assembly screws as Fig 2 1 2 Used to convert a unit price to a half pound 1 4 Used to convert a unit price to a quarter pound PRINT Used to print out a label POST BRACKET amp BOLT m Table Symbols on Display SYMBOLS
11. use for 3 seconds 5 Seconds Automatic backlight off when not in use for 5 seconds 10 Seconds Automatic backlight off when not in use for 10 seconds U 5Et U 5Et ZERO NET kg ZERO NET kg pPress ZERO key to move next function setting EL Backlight ON OFF B Use TARE key to select one of backlight auto power off option or EL Backlight ON OFF Ex Select 5 seconds auto power off option Options Description Remarks NON No printer in use DLP 50 DLP 50 printer interface U SEE U 5Et SAVE SAVE ZERO NET Ib kg Pr int NET lb kg 7g J B Press ZERO key to move next function Select the printer you re using with ER by setting Printer pressing TARE key EX DLP 50 e Cable pin layout Male Male 1 1 6 6 2 2 7 7 3 3 8 4 4 Jump the pin 5 35 P 5 to 7 on both side THANK YOU Wisi Unit PricsztI5 Total igi friaa 8 59 Label Sample 1 Chapter 4 Sales Transaction S2000Jr series may make a sales transaction either with free price or with PLU a Sales with free price hand pricing This section explains how to make a sales transaction with free price hand pricing SAVE SAVE 500 ogo ZERO NET lb kg 0000 lb kg pPlace an item on the platter and press appropriate numeric keys to input unit price Ex 1 99 for unit price lt gt Remove the item from the platter