Home

Pricing Scale - e

image

Contents

1. SYMBOL DISPLAY 1 Zor 0c Zero mode 2 TorNet Tare mode 3 M Accumulation in the memory 4 Low battery 4 01002020 V KEYBOARD FUNCTION 1 2 3 4 5 6 7 8 9 10 11 0 9 To set the unit price Upon price setting this is to display units below integral number To correct push this key to set it back to 0 and key in the new unit price When there is more than 1 piece of the same item input the unit Q TY and then the number of items with round number of over 0 up to 999 the total amount will show up in the window At this moment press to store it in Accumulation For the total price display of the commodities to be made by weight and to store the price in Accumulation Key in the price of commodities without weighing on the display of unit price for a direct input of Accumulation into memory When there is an accumulation in the memory press MR for showing the memory of the items accordingly to clear the Accumulated amount CH key the total price will display the total amount of the deal then key in the sum total paid from customer the unit price will display the change bal
2. N An Fi USER MANUAL CONTENTS I INSTRUCTION amp FEATURES aussen ee I BEFORE USING THE SCALE denia M va kao III PREPARATIONS BEFORE USE TV DESCRIPTION OF DISPLAY V KEYBOARD FUNCTION VI OPERATION FOR BACKLIGHT FUNCITON VII DESCRIPTION OF POWER SUPPLY POWER SUPPLIES POWER CONSUMPTION In order to avoid the battery blockdead please recharge the battery of the scale which is kept in warehouses over 2 months before using 1 01002020 I INSTRUCTION amp FEATURES INSTRUCTION The digital price computing scale is a precision weighing instrument Its fast accurate price computing ability is excellent for a variety of supermarkets grocery stores food services and retail stores FEATURES 2 20 Key keypad Double side LCD display vendor and customer side Durable LED backlight on vendor side Patented anti cockroach plastic ring design to prevent any insects crawling into the scale NN N Total price calculation A summation feature allows sub totaling of several items An addition feature provides Addition Calculation ability Low power indication and auto power off Battery operation AC DC NNNN N 2 01002020 II BEFORE USING THE SCALE To enable you to use this scale correctly we suggest that you read these instructions carefully III Must be prevented from getting wet If it gets wet please wipe it dry with a cloth It must not be bumped against other items or ov
3. ance for customer Put the container on the platter and press T to return to zero its weight can be eliminated if there is a signal of TARE lt 4 it indicates that the weight has been deducted After removing all items and package from the platter if there is a display of weight of package in a negative number on the weight space press the key again and the weight will run back to zero while the light of TARE lt will be disappeared CE Q TY price first press of total price M price to press M and press MR MC Press MC CH When press T Z When the weight window of the scale does not return zero press this key to put it back to zero and the light of zero will be appeared 5 01002020 VI OPERATION FOR BACKLIGHT FUNCITON If scale is equipped with backlight There are two methods to operate it vi L 5 followed by pressing 4 key 1 Press Z key the unit weight displays I_ backlight mode is Auto backlight 1 Tri 5 followed by pressing 5 Press Z key the unit weight displays I_ key backlight is off 2 Press 0 key about 2 seconds the buzzer will beeps three times which means the scale have switch to backlight function automatically Auto backlight mode The backlight will be on when the platter is placed the loading must be over 10d or pressin
4. erloaded with excessively heavy weights The load must not exceed the maximum capacity of the scale Keep it away from high temperatures and damp conditions If the machine will not be used for some time please clean it and store in a polythene bag A desiccant may be included If the machine will not be used for some time the scale must be recharged the internal battery every 3 months When it is used please recharge scale before using When recharging it should be prevented power is excessively high or discharged This may make the life of battery decreased PREPARATIONS BEFORE USE Place the scale on a stable surface Adjust the four feet to center the bubble on the scale Avoid hot sunshine directly on the scale or near the exhaust port of ventilating system There should be no weight on the scale when power is turned on Please note when symbol appears on the screen the scale needs recharging Commodity should be placed at the center of platter when being weighed and can t be exceeded to the dimension of the platter 3 01002020 IV DESCRIPTION OFDISPLAY DIGIT DISPLAY 1 WEIGHT display window 5 digits with ahead to show negative numbers 2 UNIT PRICE display window 5 digits with the decimal point to set therein 3 TOTAL PRICE display window 6 digits with 2 digit behind the decimal point 4 digits before it or to fix according to difference of currency systems
5. g any keys on the keyboard When the scale returns to zero the backlight will be off automatically after 5 seconds 4 Note The backlight status will be memorized After the scale is off the backlight mode will be remain same as to turning on the scale next time 6 01002020 VII DESCRIPTION OE POWER SUPPLY POWER SUPPLIES DC 6V 4AH internal rechargeable battery DC 6V 10AH internal rechargeable battery 9V DC via mains adaptor POWER CONSUMPTION About DC 20mA About DC 40mA with backlight LOW BATTERY When appears at the corner of the display the battery needs recharging 4 Note Please charge the battery while the display is shown symbol If you don t charge in time after using 20 30 hours the power will be automatically cut off to protect the battery life Please immediately charge the battery 7 01002020