1. Ce 7 TS Auto Auto position unit 810 356 When integrated with the HM200 series combined with automeasuring unit this unit can achieve l both enhanced measurement efficiency and Automatic XY stage reduced measurement variation due to human I ST SI nj qe z HUNS errors at the same time thanks to the automatic s l indentation reading function and the automatic PC AT driver unit Motor control board stage control function which is helpful for multiple PC igi point measurement of hardness oe Dita ee eee a Auto position Auto focus unit 810 357 When integrated with the HM200 series l unit SC AP avert combined with the automeasuring unit and l the auto position unit this unit allows all l AF auto stage the necessary operations of hardness testing __ Lens tube unit focus pattern to be automatically and speedily performed PC Xf install i HM 211 810 352 gt actory installed option l HM 221 810 353 royale Joystick board l x When building in the video camera unit remove the eyepiece unit of the measuring microscope standard accessory If the Auto measuring unit is added it will be exclusively used in place of the measuring microscope or video camera unit For the exclusive use of the Auto measuring unit or video camera unit an optional camera power unit Order No 19BAA360 is required If the Auto focus unit is added the focus line is visible within th
2. 100V Standard Accessories Order No Item name Description Quantity 19BAA407 Measuring microscope Digital type eyepiece 10X 1 1 10X for measurement W D 5 6mm with spacer washer 1 2 standard for HM 211 221 50X for measurement W D 19BAA439 Objective 1 1 mm with spacer washer 1 standard for HM 211 221 100X for measurement W D 2 5mm with spacer 1 4 washer standard for HM 221 19BAA058 Diamond indenter Vickers Liner provided for HM 211 P Vickers for low test force PAR Liner provided for HM 211 11BAA578 Extension shaft For elevation shaft 38mm with two setscrews For elevation shaft 76mm 1 1 810 074 XY stage digital type 7 a a 25 Y mm Material bakelite 11 W x13 H x42 D mm Jaw opening 54mm 5 x 8mm reen or eyepiece 810 817 Objective NO N 19BAA440 Objective 19BAA133 810 016 tandard vise ise setscrew 938905 ptical filter 11BAA961 Rubber hood 19BAA522 Camera mount adapter eveling screw 02ZAA000 gt 02DEA471 Hardness test block specimen stage WGN oO fed N MD lt s NI gt I Classification No marking 125V AC 7A 1 8M K ust cover 7OOHMVO 3 1 25mmidia x 6mm thickness No 1300 Phillips 2x100 No 205 Flathead 1 2 Sub tense 1 5mm Sub tense 2 0mm Sub tense 2 5mm Sub tense 3 0mm ub tense 4 0mm Dia 20 x 100 No 2 Blanking the mounting R hole of the carrying h
3. Test Equipment and Seismometers I ns Pew _ vy ee Pe ee eed ee eee PATOL RHI CLV ET ALO LIPLIL Glia 1 at en eee ee ee E E F l lt A N Y a T B i a A v Catalog No E4308 352 353 Micro Vickers hardness testing machines have been released from limitations on test force The latest electromagnetic force motor employed in the loading mechanism enables arbitrary test forces to be set greatly widening the choice of test conditions Mitutoyo HM200 series Features Electromagnetic force motor employed in the loading mechanism The latest electromagnetic torce motor used in the loading mechanism has enabled the test force to be freely selected see test force specifications over the wide range of 0 4903mN 0 05gf to 19610mN 2kgf It is also possible to freely set the time for loading and load dwell time Now your desire for absolute control over the indentation size in hardness testing can be satisfied The HM 200 series always offers the test force most appropriate for the specimen material and shape Note Hardness values may vary with the setting of test force depending on the material and surface finish of the specimen Equipped with a fracture toughness evaluation function tor ceramics It is possible to perform not only the Vickers hardness test but also a fracture toughness test IF test JIS R 1607 1995 on ceramics 3 Automatic turret mechanism manual operation possible Automatic swi
4. andle SR44 1 5V 06 06 astic Phillips screwdriver recision flathead screwdriver ex head screwdriver ex head screwdriver exagonal wrench exagonal wrench Hexagonal wrench 510434 Holder carrying handle 512926 938882 Silver oxide cell ccessory container box 99MBG068 User s Manual Certificate of hardness test block est certificate Halogen bulb illuminator house 19BAA207 I I Ly IT Vy BV l J lbI QPS MD QD fed gt g gt N MD ao me WN m Kya NI CY Q Oo BK ae 4 12V 50W NA57901 KLV lt D N D For 100 120V AC 250V AC 11BAB908 2A one unit installed 2 1 2 T1 I Ss D gt G a ap O ta D 5 o S on 1 is mounted on the main unit during on site installation 2 is provided with a factory set spacer of an appropriate size when shipping 3 is provided with one unit according to the model as installed in the main unit 4 vary with the destination Mitutoyo For the main unit of the hardness tester Order No Itemname Description 19BAA061 Diamond indenter Knoop provided with the liner for HM 211 Knoop low test force provided with the liner for HM 222 1OOHMV Test force 9 807N 980 7mN 98 07mN 200HMV Test force 9 807N 980 7mN 98 07mN 300HMV Test force 9 807N 980 7mN 98 07mN 400HMV Test force 9 807N 980 7mN 98 07mN 500HMV Te
5. e view field of the measuring microscope 2 The XY stage digital type standard accessory is dismounted if the Automatic XY stage is to be used Therefore if the Auto position unit is added and only the hardness tester is used XY position data cannot be obtained Optional Accessories System buildup items F 354 810 357 Order No Item name Description remarks Quantity A L as camera unit Auto measuring unit Auto position unit Auto focus unit Software C M ee ee ee a oo O S A a o o a T peaa ooo oa g o o o pose E e ae Neorg pr eea Mea EE CCOR co GH or RN aw a Ta E O E E E E ma Caen a rr EACLE rane gebbe S O S E S i 1 PT mi I ly ty ISTE 1BAB908 Fuse For 100 120V AC 250V AC one unit _ SRT E R50 ACTA etal E E 7 E i a c E naaa veror one PT TBARS SAE e T E A ECOL poaae o EE E A E E E A E BANTI Automatic XY stage S phase stepping motorspecficaton O oo o SSO T SSO T T9BAA378 Automatic XY stage cable Connecing the Automatic XY stage andPCATGmwerunt 1 v __ a e a O 1 1 1 1 1 1 i lt I i i vV E SSCS 1 SS Cd E Cr eloko OCS 3 S Ud o S COC S TBACSBT flowtckboad A S Yd Cdr TAAABZ6 Lens tube focus paner Monor be needed orautofoamng O OOOO O o dT Cd Or o SBAAG62 HEPC dedicated cable Connecting the main unit andthe dedicated personal computes n 1 OOOO S GBAAGGO Camefaponerunt CCCP TCP Crd COC Cd 1 vary with the desti
6. her accessories Order No Model No Specification 810 092 VP 1200 Seiko make 4 19BAA242 For RS 232C 9P 9P 2m 810 622 DPU 414 Seiko make 19BAA266 For DPU 414 2m 19BAA157 For DPU 414 10 rolls 264 504 Digimatic Mini processor DP 1VR 937387 Connecting cable For DP 1VR 1m O9EAA082 Recording paper For DP 1VR 10 rolls Traceability chart Inspection certificate Calibration Calibration certificate P certificate 1 Test certificate for Knoop hardness will be issued only when it has been shipped with the Knoop indenter built into the machine 2 Items that can be mounted after the on site installation of the machine by the service engineer authorized by Mitutoyo 3 Factory set option 4 A TV camera unit is required when using the video printer VP 1200 Configuration Diagram for Upgrading the System Upgrading of the system is possible with options shown below CCD Video camera unit 810 354 Auto measuring unit 810 355 1 perm Camera When integrated with the HM200 ee series this unit helps reduce human Frame grabber PC errors in measurement as it l It is available only for automatically measures the diagonal l l i CCD camera l l Video i When integrated with the HM200 H systems designated for the indentation and calculates the Monit ae l ee series this unit can reduce human anciaretapies Software Japan hardness value errors in measurement with the eye a
7. nation 2 is needed for the exclusive use of the video camera unit or Auto measuring unit when both are mounted Note Mitutoyo products are included in appendix 1 of Export Administration Regulations and accordingly an export license may be required when exporting 15 100605 1 ENE Printed in Japan virere ielcers Coordinate Measuring Machines Vision Measuring Systems Optical Measuring K n f 0 fi Test Equipment and Dnrm N AACIIFAMmAnT OIN Vilurehbie ei e PME PVINGQOUERTTINITY Seismometers ee Oe Digital Scale and DRO Systems se bo J P oe Small Tool Instruments and Data Management Mitutoyo Corporation 20 1 Sakado 1 Chome Takatsu ku Kawasaki shi Kanagawa 213 8533 Japan T 81 0 44 813 8230 F 81 0 44 813 8231 htto Avww mitutoyo co p Mitutoyo
8. ndentations clearly visible leading less variation and reducing the chance of error when measuring the diagonal lengths Energy saving function An energy saving function is incorporated that automatically turns off the control panel and illumination unit if the machine is left unattended for a significant length of time Specifications OdaNo E r 810 3531 Model No HW221 iN 3307 red test gi a1 02 i0 force mN BONETE 196 1 294 2 490 3 980 7 sata a A a0 5000 e a 00 0 Test force of 980 7mN 100gf or less can be set in Only the test force of 0 4903mN 0 05qf is available below 0 9807mN 0 19f Test force of 0 9807mN 0 1gf or more and below 9 807mN 1gf can be set in increments of a increments of 9 807mN 1gf 0 9807mN 0 198 can be saved Test force of 980 7mN 100gf or more can be set ee ao 1gf or more and below 980 7mN 100gf can be set in increments of EEO Test force of 980 7mN 100gf or more can be set in increments of 98 07mN 10gf Test force control Force generation by electromagnetic and automatic control load dwell unload Test force dwell time Possible to set in increments of 1 sec between 0 and 999 sec Specimen size 133 mm in height 160 mm in depth as measured from the indenter shaft Optical performance Infinity corrected optical system light source halogen bulb variable ae fixed field stop measuring microscope camera optical path switching ne 10X for measurement 50X for measurement up 10X for measu
9. rement 50X for measurement 100X for measurement up to four objectives can be to four objectives can be mounted mounted Maximum Sie oc BAN a l measurable length Objective 10X 700um 50X 140um Objective 10X 700um 50X 140um 100X 70um Turret switching Motor driven manual selector is also possible XY stage With digital micrometer heads table top size 100x100 mm travel range 25 X x25 Y mm resolution 1um Display on the LCD color touch panel Data display The length of the diagonal of indentation 5 digit maximum minimum of 0 01ym for objectives of 50X or over function hardness value 4 digit maximum minimum hardness of 0 1 Load dwell unload GO NG judgment OK NG converted hardness indenter HV HK XY table position oe Cylindrical compensation spherical compensation reading compensation ies eae Selectable from SAE ASTM BSi860 DIN Mitutoyo unction Test conditions guiding function Calculates test force from the expected indentation depth thickness of specimen and the expected hardness Statistical calculation Number function Standard deviation n 1 Standard deviation n Output Digimatic 1CH Centronics 1CH RS232C 1CH External dimensions External dimensions Approx 400 W x 625 D x 600 H mm Installation space Approx 600 W x 780 D x 1000 H mm or over Mass Approx 43 kg Power supply 100 120V AC 50 60Hz 90VA E Suffix A for 110V C for 100V D for 220 230V E for 240V DC for China K for Korea or non for
10. st force 9 807N 980 7mN 98 07mN 600HMV Test force 9 807N 980 7mN 98 07mN 700HMV Test force 9 807N 980 7mN 98 07mN 800HMV Test force 9 807N 980 7mN 98 07mN 900HMV Test force 9 807N 980 7mN 98 07mN AOHMV Test force 9 807N 980 7mN 98 07mN 19BAA062 Diamond indenter 1 19BAA001 Hardness test block 19BAA002 Hardness test block 19BAA003 Hardness test block 19BAA004 Hardness test block 19BAA005 Hardness test block 19BAA006 Hardness test block 19BAA007 Hardness test block 19BAA008 Hardness test block 19BAA009 Hardness test block 19BAA010 Hardness test block 810 017 Special vise Jaw opening 100mm 810 013 Thickness within 5mm 810 014 Specimen wire holder horizontal type Diameter 0 4 3mm 810 015 Diameter 0 4 4mm P Jaw opening 37mm Tiltin icici re ce Rotating Hae 25 810 020 Thickness within 30 mm 810 018 Minimum reading 1 310 084 Height within 32mm Width dia within 38mm l l Thickness within 3mm Width 810 085 Adjustable specimen thin plate holder within 56mm 810 095 Rotatable tilting specimen holder p 20mm or more Width ja 15 55mm 19BAA523 50mm stroke 810 616 5X W D 13 5mm 2 810 618 Objective J20X W D 1 8mm 2 19BAA440 100X W D 2 5mm 2 OPDEROSD 3 11AAB250 Objective mirror magnification 13 piece set from 0 8 to 2 0mm adjustment spacer for single unit in increments of 0 1mm 11AAB355 For HM 21 1 3 11AAB356 For HM 221 3 Ot
11. tching is possible between the indenter and the objectives Objective Up to four objectives can be installed 1 Measuring microscope digital type Standard objectives 10X 50X HM 211 10X 50X 100X HM 221 2 Illumination unit Indenter shaft unit Up to two shafts can be installed Standard indenter Vickers indenter 1 pc HM 211 HM 221 7 Optical path for camera 5 XY stage digital type Table top size 100x100mm Travel range 25x25mm Provided with digital micrometer head standard accessory 8 Optical path selector 4 Vise Standard vise standard accessory Maximum jaw opening 51mm 6 Touch screen type control panel You can not only follow the basic steps of hardness 9 Rear panel testing but also see the hardness value in different hardness scales and testing conditions at a glance Mitutoyo Long working distance objectives The objectives used enable a very comfortable working distance between the objective and the specimen surface This greatly reduces the possibility of collision between the specimen and the objective during focusing operations For 50X objective a clearance of 0 4 mm in HM 100 series has been improved to increase 1 1 mm in HM 200 series Built in variable aperture stop The contrast that is most appropriate for the magnification of the objective can be obtained by manipulating the variable aperture stop in the illumination unit This makes the i