Home
User manual
Contents
1. 010 0 0 07 30 lt a O A When there is any timing scheduled for the current day the small clock on the bottom right corner of the screen will remain on Press enter to go back to the options menu KNX Graphic controller 9de 16 USER MANUAL ingenium O S MEKBUS vo 1 www ingeniumsl com 3 2 2 DAY AND HOUR The MEKBUS is a device that does not keep the hour exactly by itself it requires an RTC real time clock to update the hour when it is rebooted In case of do not having it in the installation it is possible to set the day and hour manually from this menu 16 30 59 DOMINGO Press and hold for some seconds over the hour minutes or seconds to set a new value with the keyboard FIJE HORA Y OK Note The hour is in 24h format The day of the week can be change in the same way Press and hold to set a new day with the keyboard where the number O is Sunday and 6 is Saturday DOMINGO FIJE D A Y OK Note When the device is disconnected from the power supply it is necessary to set the day and hour manually If the installation incorporates the Ingenium RTC it is done automatically see the RTC documentation for further information Press over any point of the screen to go back to the main menu KNX Graphic controller 10 de 16 ingenium O senium USER MANUAL MEKBUS vo 1 3 2 3 INTRUSION ALARM aS This icon shows the intrusion alarm menu where
2. Graphic controller MEKBUS VO 1 USER MANUAL ingenium Parque Tecnol gico de Asturias Parcela 50 33428 Llanera Asturias Spain Tel 34 985 118 859 Fax 34 984 283 560 ingeniumsl ingeniumsl com www ingeniumsl com TECHNICAL SUPPORT Tel 34 985 113 339 tecnico ingeniumsl com USER MANUAL lt gt ingenium AD www ingeniumsl com MEKBUS v0 1 VW Index 1 General description 2 Technical description 2 1 MEKBUS 2 2 MEKBUS G 3 Operation modes 3 1 Pages 3 1 1 Point to point 3 1 2 Scenes 3 2 Menu 3 2 1 Timings 3 2 2 Day and hour 3 2 3 Intrusion alarm 3 2 4 Presence simulation on NSB BP bh U W U N pn nm WU HO 4 Installation ba A 4 1 MEKBUS pa A 4 2 MEKBUS G pa Ul KNX Graphic controller 1de16 ingenium O Senium USER MANUAL MEKBUS v0 1 1 GENERAL DESCRIPTION The MEKBUS is a 4 3 color touch screen to control and monitor elements in a KNX installation Two models available e Resistive MEKBUS e Capacitive MEKBUS G Designed to replace conventional switches and push buttons it allows to include 4 different pages to locate icons upon 3D drawings plans pictures etc and to control up to 20 installation points and to execute up to 20 programmable scenes by those allusive icons Characteristics Adifferent pages to locate icons upon 3D drawings plans pictures etc 20 point to point controls with different representative
3. an e Po universal box in the wall with A gt A i 4 screws following the measurements shown in the diagram ey We eee E E MicroSD o 8 memory card To change skins or include internal thermostat ref STIBUS SD Finally press on the embellisher KNX connection Using ConectorT for KNX upply BUS 4 gt KN X Graphic controller 14 de 16 USER MANUAL MEKBUS vo 1 4 2 MEKBUS G SAME enium www ingeniumsl com N Use external mounting box is essential in any type of installation allows future removal of the device 129mm l 14mm 120mm T E El E O O E 8 2 E AN 3 Glue connector housing In EMBEDDED installations Before fitting de device inside remove external border in MASONRY WALL installation Installation options SURFACE mounted on universal box gt lt 8mm lt 4mm Mounting box Device When installed the mounting box fit the device inside Plastic part to remove in EMBEDDED E MBEDOES in PLASTERBOARD installation for ConectorT access in MASONRY WALL MicroSD miss memory card Device To change skins or include Rear internal thermostat ref STI
4. change any password the screen requires first to enter the highest priority password administrator CAMBIO DE CLAVE INTR CLAVE SUPERVISOR Then select the level of password to be changed by pressing form 1 to 5 on the keyboard and enter the new one twice to confirm it If the level selected is 5 you will change the administrator code CONFIRME NUEVA CLAVE CLAVE SELECCIONADA 3 KNX Graphic controller 12 de 16 USER MANUAL gt ingenium AZ www ingeniumsl com MEKBUS vo 1 VW 3 2 4 PRESENCE SIMULATION The presence simulation allows to copy the last actions done by the customer and reproduces them as if there were people at home switching on and off the lights raising the blinds etc a SIMULACION DESACTIVADA PULSE PARA ATIVAR Press over this icon to show the presence simulation menu and activate it by entering any intrusion code and pressing ok with the keyboard INTRODUZCA CLAVE PARA ACTIVAR SIMULACION When it is activated any code is required to deactivate it just press the screen a SIMULACION ON PULSE PARA DESACTIVAR When the presence simulation is activated the small house icon on the bottom right corner of the screen will remain on Press enter to go back to the options menu KNX Graphic controller 13 de 16 www ingeniumsl com USER MANUAL cen MEKBUS vo 1 4 INSTALLATION 4 1 MEKBUS 145mm Installation 125mm o This device is fixed in
5. BUS SD KNX connection Using ConectorT for KNX KNX Graphic controller 15 de 16 ngenium AS www ingeniumsl com Parque Tecnol gico de Asturias Parcela 50 33428 Llanera Asturias Spain Tel 34 985 118 859 Fax 34 984 283 560 ingeniumslOingeniumsl com www ingeniumsl com TS KN x 0584 2007 ER
6. T TO POINT The point to point row upper one allows to select up to 16 elements of the installation to be controlled individually The following icons are available On Off lightning activate or deactivate the lightning of a zone name indicated below and shows the actual state of the light KN X Graphic controller 4 de 16 USER MANUAL MEKBUS vo 1 ingenium AS www ingeniumsl com Dimmer lightning This icon shows the different lightning level The level desired can be set by pressing it Use the arrow icon to return to the main menu Thermostat By pressing this icon we access to a window that shows the actual temperature value left and the desired value right Slide the finger up and down to increase or decrease the set value Use the arrow icon to return to the main menu Use the buttons below to set the operation mode of the thermostat winter mode summer mode mixed etc Pushbutton By pressing this icon can be changed the state of any on off output of the installation Climate By pressing this icon can be changed the state of any on off output of the installation Flooding By pressing this icon can be changed the state of any on off output of the installation Watering By pressing this icon can be changed the state of any on off output of the installation Graphic controller 5 de 16 USER MANUAL MEKBUS vo 1 insenium O s www ingeniumsl com Blind control This icon sho
7. icons lights blinds climate control etc 20 scenes execution with a maximum of 64 events each Upto 10 weekly timing programming Possibility to arm disarm alarm and to activate presence simulation Possibility of managing an independent climate area adding a temperature sensor ref STIBUS SD in the microSD slot Real presence simulation Programmable from a specific application trough microSD card 2GB max FAT16 format KNX Graphic controller 2de 16 ingenium O Senium USER MANUAL MEKBUS v0 1 2 TECHNICAL DESCRIPTION 2 1 MEKBUS 4 3 COLOR RESISTIVE TOUCH SCREEN Supply 29 Vcc from auxiliary power supply or from KNX BUS Consumption depends on source o Auxiliary Power Supply 18 30Vdc Recommended 80 mA from auxiliary power supply 1mA from KNX BUS o KNX BUS Optional 80mA from KNX BUS Size 145x86x10mm Mounting On universal distribution box screwed on wall Programming card MicroSD 2GB max FAT16 format 2 2 MEKBUS G 4 3 COLOR CAPACITIVE TOUCH SCREEN Supply 29 Vcc from auxiliary power supply or from KNX BUS Consumption depends on source o Auxiliary Power Supply 18 30Vdc Recommended 80 mA from auxiliary power supply 1mA from KNX BUS o KNX BUS Optional 80mA from KNX BUS Size 129x88x4mm 13 mm depth Mounting o Surface Flush mounting with box included o On universal distribution box screwed on wall o Easily
8. mounting on plasterboard wall Programming card MicroSD 2GB max FAT16 format N Remarks Feed low voltage lines BUS and inputs in separate ducting to that of power 230V and outputs to ensure there is enough insulation and avoid interferences Do not connect the main voltages 230 V or any other external voltages to any point of the BUS KNX Graphic controller 3de16 ingenium O Senium USER MANUAL MEKBUS vo 1 3 OPERATION MODES In the main window of the MEKBUS you can have up to 4 different pages with point to point icons that control lights blinds etc individually or scenarios a group of actions that are executed simultaneously 3 1 PAGES Main window shows pages that you have included in your project 3D drawings plans pictures etc 4 pages maximum Over those pages you can find icons linked to point to point controls or to events All of them should be programmed using the application we will see in Error No se encuentra el origen de la referencia Error No se encuentra el origen de la referencia If the project has more than one page you can shift between them by simply dragging your finger left or right depending which page you want to display If you drag from right to left will change to the next page If you drag from left to right will change to the previous one Below are some of the most common controls which are possible to include in the installations 3 1 1 POIN
9. the alarm can be activated or deactivated from The MEKBUS can manage up to 4 different zones Activation Deactivation Firs select the zone to be activated by the right and left arrows on the top of the screen and then press over the text press to arm at the bottom of the screen or SELECCIONE ZONA Y PULSE PARA ARMAR Enter the password with the keyboard and press ok to validate Each zone can be activated or deactivated with 5 different codes which are initially configured as Code 1 1111 minimum priority Code 2 2222 Code 3 3333 Code 4 4444 Code 5 5555 maximum priority To activate or deactivate the intrusion alarm enter a code which could be any of the them Take into account that the codes are prioritized where code 1 is minimum priority and 5 is the maximum For example if the alarm is activated by the code 4 it can only be deactivated by an equal of higher code 4 or 5 While the alarm is being activated the small man at the bottom right corner of the screen is blinking When the screen receives the activation confirmation after 30 seconds typically it remains on Press enter to go back to the options menu KNX Graphic controller 11 de 16 O n bn USER MANUAL MEKBUS vo 1 Password change Press and hold over the man on the left in the intrusion menu to change the activation passwords 9 O or SELECCIONE ZONA Y PULSE PARA ARMAR To
10. the presence simulation and to set date and hour Press and slide up to access to this menu To come back to the pages control press and slide down The appearance of this menu will be KNX Graphic controller 7 de 16 USER MANUAL as MEKBUS vo 1 Next paragraphs contain explanations for each tool 3 2 1 TIMINGS O The timings allow to set the day and hour of the week when the MEKBUS executes any scene We can program up to 10 timings per week Press the corresponding icon to show the timings menu TEMPORIZACION ESCENA O 010 O mw O 08 00 Gad D LMXJVS First select the number of timing to use and the scene that will be scheduled they must be programmed before with left and right arrows in the top right corner of the screen Then press over the hour to set the hours and minutes of execution with the keyboard a 4 FIJE HORA Y OK FIJE MINUTO Y OK Note The hour is in 24h format KNX Graphic controller 8 de 16 USER MANUAL y Smam MEKBUS vo 1 After that select the days of the week in the bottom of the screen just by pressing on them to activate and deactivate The initial indicates that the day is activated and the scene will be executed and a hyphen indicates that it is deactivated for this day Finally activate or deactivate the timing by pressing over the clock on the left If the clock is on it indicates that the scene is scheduled and will be executed TEMPORIZACION ESCENA O
11. ws the state of a blind By pressing it we access to a window that allows to set the blind position by sliding up and down the finger Use the arrow icon to return to the main menu Sound control By pressing this icon we access to a new window that allows to set the volume and select the channel of a SoniBUS Press over the channel box to change it and slide the finger up and down to increase or decrease the volume Use the arrow icon to return to the main menu The available functions depend on the user s needs and can vary by programming Graphic controller 6 de 16 ingenium O Senium USER MANUAL MEKBUS v0 1 3 1 2 SCENES Each scene is a group of actions that are executed simultaneously These scenes can only be configured by programming A scene will be executed by pressing the corresponding icon name of the scene indicated below The icon will remain on while the scene is in execution BE For example a usually programmed scene is one to control every light or every blind in the house By pressing the scene called ALL OFF we can switch off every light of the house so it is not necessary to switch off each room individually or by pressing the scene ALL DOWN we can close every blind The available scenes depend on the user s needs and can vary by programming 3 2 MENU There is another window with fixed icons that is used to manage the intrusion alarm program timings activate or deactivate