1. 6 www acti com ACTI Connecting Vision vA TCM 5611 Hardware User s Manual Safety Instructions Don t use the power supply with other voltages This device is likely to be damaged or damage other equipments personnel if you use a power supply with different voltage than the one included with this device All warranty of this product will be voided in the situations above Don t open the housing of the product Cleaning Disconnect this video product from the power supply before cleaning Attachments Do not use attachments not recommended by the video product manufacturer as they may cause hazards Water and Moisture Do not use this video product near water for example near a bathtub washbowl kitchen sink or laundry tub in a wet basement or near a swimming pool and the like Don t use accessories not recommended by the manufacturer Only install this device and the power supply in a dry place protected from weather Servicing Do not attempt to service this video product yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel Damage Requiring service Disconnect this video product from the power supply immediately and refer servicing to qualified service personnel under the following conditions 1 When the power supply cord or plug is damaged NO If liquid has been spilled or objects have fallen into
2. TCM 561 1 Series H 264 Megapixel IP D N PoE Box Camera DC 12V PoE Ver 2010 1 5 m4 ACT ACTI Connecting Vision vA TCM 5611 Hardware User s Manual Table of Contents 0 Precautions 3 1 Introduction 4 Package COMEN ES anran rer won O A E E NS 4 Features and Benefits oiaanecanenasudieseavecasdentetanenecnsnnerasavngeaudeediateceasecens 5 Safety INSU ONS secioni niee ONENE 7 Physical description sueeeconsnacecancesennscatadesannsaancesinivessnecsteesgeiedeuenenumaees 9 Basic Connections ccccccceeeceeeeeeeeeeeceeeseeesenesanseanseanseaneeeeeeeseneees 13 Prod ct SOCCITICAT OM scaud nnccsusuessaivewnneusiaweseiitesadeniusceaiauasacsmeneeiens 14 2 Accessing Camera 15 If you have DHCP server router in your network c 02000 15 If you do NOT have DHCP server router in your network 15 2 www acti com ACTI Connecting Vision vA TCM 5611 Hardware User s Manual 0 Precautions Read these instructions You should read all the safety and operating instructions before using this product Heed all warnings You must adhere to all the warnings on the product and in the instruction manual Failure to follow the safety instruction given may directly endanger people cause damage to the system or to other equipment Servicing Do not attempt to service this video device yourself as opening or removing covers may expose you to dangerous voltage or other hazards Re
3. acti E Host Date amp Time E NETWORK Link Speed amp Duplex Mode Connection Type DNS DDNS Port Mapping Tos UPnP E Video amp Audio Advance Media 1 Media 2 User Maintain Systeminfo Factory Default Firmware Upgrade Reboot Save amp Reboot Logout Streaming Mode Single Stream Mode Encoder Type Resolution 1280x720 Frame Rate _ _ Approx 26 FPS 0 50 100 App Video Bitrate Mode Constant Bit Rate w Video Max Bit Rate Video Bit Rate 3M v Apply Reset 19 www acti com
4. an auxiliary connector for mains power to the this camera unit This pin can also be used to power auxiliary equipment with a maximum current of 0 ACTI Connecting Vision vA TCM 5611 Hardware User s Manual Pin 3 Digital Input Connect to GND to activate or leave floating Must not be exposed to or unconnected to deactivate voltages greater than 30V DC Pin 4 Transistor Uses an open collector NPN transistor with Max load lt 100mA Output the emitter connected to the GND pin If used Max voltage 24V DC with an external relay a diode must be to the transistor connected in parallel with the load for protection against transient voltages The I O terminal pins are numbered from the top down 1 ios 4 pe 4 i Connect input output devices to the camera as follows 1 Attach the cables for the device securely to the supplied green connector block 2 Once the cables are connected push the connector block into the terminal connector also green on the camera FUSE 1A 2 lt lt POWER INPUT EARTH GND 3 l sw lt RELAY lt O lt CO o DC POWER DI 1 ACTI Connecting Vision vA TCM 5611 Hardware User s Manual 5 Power Input Connect the power adaptor here if your power input is DC12V DESCRIPTION DC Power Input Ground Pin 6 DC Iris DC Iris Lens Control Port 12 ACTI Con
5. acquire network address by itself Find and access the device with our IP Utility program You may download it at http www acti com product detail Software ACTi_Utility_Suite If you do NOT have DHCP server router in your network 1 Configure your PC to use the same subnet by changing your PC s IP address to the subnet with prefix 192 168 0 XXX The last number should be anything from 1 to 254 except 100 and other occupied IP addresses Subnet mask should be 255 555 255 0 2 The default IP used by this device is 192 168 0 100 Please make sure your PC is NOT using this address and that no two equipments use the same IP address in the network 3 Change your IP address by going to Control Panel gt Manage Network Connections gt Right click on the connection to change gt Option gt TCP IP IPv4 Properties s ACTI Connecting Vision vA TCM 5611 Hardware User s Manual Internet Protocol TCP IP Properties 2x Genera You can get IP settings assigned automatically i your network supports thes capability Othemvise you need to ask your network administrator for Please set the settings as below the appropriate IP settings C Obtain an IP addess automatically Use the following IP address IP address 192 168 0 101 IP address 192 168 O xxx Subnet mask 255 255 255 0 Subnet mask 255 255 255 0 Default gateway Use the following DNS server addre
6. side to the front There are two types of mounting blocks and this device uses the white version Please do not use the black version 4 www acti com ACTI Connecting Vision vA TCM 5611 Hardware User s Manual Features and Benefits This is a cutting edge digital video surveillance camera It can compress and transmit real time images with outstanding image quality 18 FPS SXGA 1280x1024 through a standard TCP IP network This camera is your best choice to build an intelligent IP surveillance system H 264 MPEG 4 MJPEG Triple Codec Dual Streaming This device supports 3 compression formats H 264 MPEG 4 and MJPEG It brings superior image quality at 18 frames per second up to a resolution of SXGA 1280 x 1024 pixels and offers up to 26 frames per second in HD720 1280x720 In D1 720 x 480 VGA 640 x 480 QVGA QQVGA the device reaches 30 frames per second Wide Dynamic Range This IP camera includes a special process that enhances the view in the brightest and darkest areas This provides for more evenly illuminated image and brings out greater details to the eye DC Iris Control Using exposure control via DC Iris this camera automatically adjusts incoming light levels to achieve the best video performance Wildly fluctuating outdoor lighting condition is no longer an issue with your video quality Built in Hardware Motion Detection No more external motion sensors are required You may assign
7. up to 3 video motion detection areas By tuning the object size and sensitivity it will reliably detect objects passing though in view Hardware motion detection also offers better sensitivity and faster response time than software motion detection Powerful Bundled Surveillance Software To extend the capabilities of the IP Box Camera series a powerful surveillance program is included in the package for free Users can easily use an existing PC as a digital video recorder Scheduled recording and manual recording keep every important video recorded in the local hard disk Reliable and accurate motion detection with instant warning enables immediate response in every condition Quick and simple search and playback function lets you easily find the images and video you want 5 www acti com ACTI Connecting Vision vA TCM 5611 Hardware User s Manual Software Development Kit Support This IP Box Camera can be integrated or controlled by applications from third party software developers Software developers can save considerable efforts by using our Streaming Library or ActiveX control Please contact us for details on integration support Digital Time Code Embedded The Digital Time Code Embedded function records video time in the video stream Therefore each image frame is marked with its original recording time It is very useful when users want to find the video at an exact time or between a certain time intervals
8. able SXGA 1280x1024 HD 720 1280x720 Video Picture Resolution VGA 640x480 Compression QVGA 320x240 Compression QQVGA 160x112 28K 6M bps 18 fps at SXGA 26 fps at HD720 30 fps at VGA 30 fps at QVGA 30 fps at QQVGA T 8kHz Mono PCM p Audio Line Audio Line Input Unbalanced 1 4Vp p 1Vrms terminal block 8kHz Mono PCM Audio Qutput Audio Line Output Unbalanced 1 4Vp p 1Vrms terminal block E ENT Input 1 TTL Terminal Block Digital Output Output 1 TTL Terminal Block Factory Default Patena e LED sid System Status Ethernet 10 100 Base T RJ 45 connector TCP UDP HTTP HTTPS DHCP PPPoE RTP RTSP DNS DDNS NTP ICMP Protocol ARP IGMP SMTP FTP UPnP IPv6 Microsoft Internet Explorer 6 0 or above ACTi SDK 10000 Password Protection Configured by the Administrator 0 C 50 C 32 F 122 F PoE IEEE 802 3af with Class 3 RENE r 5 16 W DC 12 V ower Power Consumption ion 6 24 W PoE 129 Dimensions WxHxL 67mm x 55mm x 129 5mm Physical 2 64 x 2 17 x 5 10 400g 0 88lb Approvals CE FCC 1a ACTI Connecting Vision vA TCM 5611 Hardware User s Manual 2 Accessing Camera If you have DHCP server router in your network Many network server routers are able to automatically provide IP addresses through DHCP If you are using such a network just plug in your computer and IP Box Cam into the network and your IP device will
9. fer all servicing to qualified service personnel Trademarks All names used in this manual are probably registered trademarks of respective companies Liability Every reasonable care has been taken during the writing of this manual Please inform your local office if you find any inaccuracies or omissions We cannot be held responsible for any typographical or technical errors and reserve the right to make changes to the product and manuals without prior notice FCC CE Regulation NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and If not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the users will be required to correct the interference at their own expense 3 www acti com ACTI Connecting Vision vA TCM 5611 Hardware User s Manual 1 Introduction Package Contents TCM 5611 Series Power Adaptor Optional Terminal Blocks for Power amp DI O Warranty Card Accessory For the mounting block please attach it flat
10. necting Vision vA TCM 5611 Hardware User s Manual Basic Connections Follow the procedures below to connect the IP device to the respective apparatuses If you have a PoE Power over Ethernet supported switch or injector 1 Connect your IP Box Camera to the Switch Injector by CAT5 or CAT6 cables with RJ45 connector 2 Connect your Switch Injector to PC with another CAT5 CAT6 network cable If your switch does not support PoE and you are powering the camera with power adaptor 1 Connect the power adaptor to IP Box Camera 2 Connect IP device s Ethernet port to Network switch via RJ45 connectors 3 Connect a PC to the Ethernet switch via RJ45 connectors Please refer our PoE Guide for more details on Power over Ethernet related concepts 3 Pq ACTI TCM 5611 Hardware User s Manual a Product Specification a 22 0 1 1 Color 0 5 Lux at F1 0 2400 K 30 IRE Color ae automatically switched to B W i mode nA 4 Lux Min scene illumination OW NA 0 05 Luxaat F1 0 2400 K SORE _ IR Sensitivity NA from 700nM to 1100nM CDS Sensor NA Yes Lens Internal Day Night Mechanical IR Cut N A Ves functions Filter Motion Detection Yes 8 Windows Electronic shutter 1 5 1 15 000 sec 1 30 1 1 000 sec 60Hz peo nluen anuai 1 25 1 1 000 sec 50Hz 1 120 sec 60Hz Teco 1 100 sec 50Hz Yes DC Iris H 264 MPEG 4 SP MJPEG simultaneous dual streams select
11. sses Preferred ONS server emate ONS server NOTE xxx should be a number from 1 to 254 except 100 which is used by the IP device Please also make sure that no two equipments use the same IP address in the 4 Open Internet Explorer Version 6 0 or above and type in the Default IP 192 168 0 100 5 When you see the login window please input default user and password Default User Admin Password 123456 Web Configurator DA acti Account Admin Password s s Language English Login Reset 6 After logging in you will see the video from camera To go to the main menu click the Setup button on the top left 16 DA ACTI Connecting Vision TCM 5611 Hardware User s Manual oy T AN Web Configurator BA A ACTi Function Media Encoder Type P J mose OSs gt 2007 01 05 21 07 58 If you are using a single camera this is enough to access the device If you are using multiple devices you need to change the current device to another unused IP address so that when the next device is connected to the network no two devices use the same IP Please perform the following steps 7 Go to Network gt Connection Type 8 Change the IP mode to Static 9 Change the IP to 192 168 0 101 or any other unused IPs Do NOT use the PC s IP address or 192 168 0 100 If this is not the first device you add to the network please also avoid other de
12. st turn off for about 15 seconds flash on for another second and turn off again By this time the reset to default operation is already completed This will take around 20 seconds from power up You may then release the reset button This length of time fluctuates slightly with the environment The Power LED light will come back on and stay on after a few more seconds The unit will start up with factory default settings automatically Restore to Default Complete Power On About 20 Seconds 3 Audio Input Output The IP device supports audio input and output with earphone jack 4 Digital Input Output Used in applications like motion detection event triggering time lapse recording alarm notifications etc the I O terminal connector provides the interface to e1 transistor output For connecting external devices such as relays and LEDs Connected devices can be activated by Output buttons on the Live View page or through video management software e1 Digital Input An alarm input for connecting devices that can toggle between an open and closed circuit for example PIRs door window contacts glass break detectors etc The device will detect the change in digital input and transmit the signal to video surveillance servers eAuxiliary power and GND Auxiliary DC Electrically connected in parallel with the con Voltage 12V DC Power input nector for the power supply this pin provides Max 1 2W not to power
13. the video product ee Ifthe video product has been directly exposed to rain or water NN If the video product does not operate normally by following the operating Instructions in 7 www acti com ACTI Connecting Vision vA TCM 5611 Hardware User s Manual this manual Adjust only those controls that are covered by the instruction manual as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the video product to its normal operation Safety Check Upon completion of any service or repairs to this video product ask the service technician to perform safety checks to determine if the video product Is in proper operating condition 8 www acti com ACTI Connecting Vision gt lt TCM 5611 Hardware User s Manual Physical description 1 Ethernet Port The IP device connects to the Ethernet via a standard RJ45 connector Supporting NWAY this IP device can auto detect the speed of local network segment 10Base T 100Base TX Ethernet 2 Reset Button Step 1 Switch off IP device by disconnecting the power cable Step 2 Press and continue to hold the Reset Button with a sharp tipped object like a pen Step 3 Reconnect the power cable while continuing to hold the reset button The Power 9 www acti com Pq ACTI TCM 5611 Hardware User s Manual enacts LED light will flash on for 3 second fir
14. vices IPs 7 ACTI Connecting Vision vA TCM 5611 Hardware User s Manual PRESTI Web Configurator D4 act Host amp Date Date amp Time SELNETWORK Link Speed amp Duplex Mode Dynamic IF Address Connection Type Static IP Address IP Address Filtering ine IF Address 192 _ 166 _ a _ 101 DDNS Subnet Mask 255 255 255 0 Port Mapping Tos ISP Gateway UPnPp PPPoE Video amp Audio Maintain heal Logout Password E Pv Apply Reset 10 Click Apply 11 Please go to Maintain gt Save amp Reboot and click Apply Internet Explorer will close after a few seconds This is normal y a KTA i URET Web Configurator gt Q ACTi F Host amp Date 2 Host Date amp Time E NETWORK Click apply to save all settings and reboot this device Video amp Audio Please wait 30 seconds for system reboot And the window will close Maintain User Account Setting Systeminfo Apply Reset Factory Default Firmware Upgrade Profile Pack Save amp Reboot Logout 12 Wait for 30 seconds and open IE again to connect to the new IP In this example 192 168 0 101 For the second device or more you add into the network please type the correct IP 13 Adjust the default Video setting by going to Video amp Audio gt Media 1 1s Live Setup ACTI Connecting Vision vA TCM 5611 Hardware User s Manual Web Configurator D4