Home

JABLOTRON 100

image

Contents

1. JABLOTRON 100 User manual TABLE OF CONTENTS Ca Introduction 2 Operating the JABLOTRON 100 System 2 Using the System Keypad 3 Alarm Setting 6 Alarm Unsetting 6 Partial Alarm Setting 7 Terminating a Triggered Alarm 7 Operating the System with a Keyfob 8 Operating the System Using a Computer and a USB Cable J Link 8 Operating the System Using the Voice Menu 8 Operating the System Using the Internet and MyJABLOTRON 9 Operating the System Using a Smartphone 10 Operating the System Using Text Messaging 10 Operating the System Remotely Using a Computer J Link 11 Operating a Selected Programmable Output by Dialling in 11 Blocking Disabling the System 11 Blocking Disabling Users 11 Blocking Disabling Detectors 12 Disabling Sections 12 Disabling Timers 12 Customizing the System 12 Changing User Access Codes 12 Changing Deleting or Adding an RFID Card Tag 13 Changing a Username or Phone Number 13 Adding Deleting a User 13 Event History 13 Using the LCD Keypad 14 Using J Link and a Computer 14 Logging Into MyJABLOTRON Web Smartphone 14 What is the MyJABLOTRON Web Interface 14 Glossary of Terms 15 a INTRODUCTION Thank you for choosing the JABLOTRON 100 security system This system is a unique flexible indoor solution for commercial and home security that offers the use of both wired and wireless devices The JABLOTRON 100 is very easy to use Everything is controlled by pressing individual control segments on a
2. ated by clicking on Internet in the main menu If the system uses a keypad with at least one controllable segment then it is possible to set unset the appropriate sections using the on screen J Link keypad by clicking on Keypad in the main menu OPERATING A SELECTED PROGRAMMABLE OUTPUT BY DIALLING IN Each telephone number stored in the system can control the system just by dialling in i e without establishing a call Dialling in consists of dialling the phone number of the SIM card used in the security system and hanging up before the system answers the call The system default is to answer the phone after the third ring approximately 15 seconds BLOCKING DISABLING THE SYSTEM cz BLOCKING DISABLING USERS Any user can be temporarily blocked e g when a user loses their card tag When a user s access is blocked their ID code or card tag will no longer be accepted by the system The user will also not be sent any text message alerts or reports to their phone Only the system administrator or service technician can block a user One method of taking away access rights is by choosing Settings gt Users gt User gt Bypass and selecting Yes on the LCD keypad Another option is to locally or remotely block a user through the J Link program by clicking on the user in the Settings gt Users gt User blocked column A blocked disabled user will be marked with a yellow or red circle until the user is re esta
3. and the on The button will start flashing red the card or tag up to the reader or input keypad acoustically indicates the exit an access code delay Once the sound stops the relevant section is set The segment button turns permanently red While setting the alarm if any detector is active e g an open window the system will react based on system configuration in one of the following ways The system will be set regardless of the system status The system will optically indicate the system status for 8 seconds flashing red and sets automatically once this period expires Setting is also possible by repeatedly pressing the segment The system will optically indicate the system status for 8 seconds flashing red and can be set only by repeatedly pressing the segment The triggered detector will inhibit the system from being set In the case of an active detector with the delayed reaction type the system will optically indicate the system status for 8 seconds flashing red and it can be set only by repeatedly pressing the segment Consult the installation with a technician in order to program the desired reaction for the system Alarm Unsetting oe lo e 1 PRESS 2 CONFIRM 3 DONE the flashing button Upon anyone ente the command by authorization hold The command is executed and the seg ring the building the entry delay is trigge a card or tag up to the reader or input ment button turns permanent
4. keypad and subsequent authorization The control segments use a simple traffic light logic which everyone can under stand The number of segments can be flexibly adapted based on the custo mer s needs The JABLOTRON 100 offers a wide range of detectors housed in a timeless design and can be operated from anywhere thanks to complete remote control access The J Link program the MyJABLOTRON web interface and the MyJABLOTRON application for smart phones allow you to control program and monitor the system remotely The JABLOTRON 100 is designed for up to 300 users and it can be divided into 15 separate sections Up to 120 detectors can be connected and the system offers up to 32 multi purpose programmable outputs e g home automation mm OPERATING THE JABLOTRON 100 SYSTEM The security system can be controlled in a number of different ways To set or unset the alarm authori zation in the form of user identification is always required The system detects the identity of the user and allows them to operate those parts of the system which they have been authorized to control pre program med The user ID date and time are recorded and stored in the system s memory each time the system is accessed This data history is available indefinitely Any authorized user can also cancel an alarm turning the alarm sound off in any part of the system regardless of their access rights However that does not automatically unset the system unless t
5. M the segment button of the the command by authorizati The command is executed once again to clear the alarm triggered section The button on hold a card or tag up to The segment button turns memory indication will flash green the reader or input an access permanently green to indicate code an unset section The red 5 DONE segment button continues to The segment button turns flash permanently green to indicate an unset section If you happen to forget to unset the system and you unwittingly trigger the alarm the keypad will flash red indicating an alarm in progress Authorization will only silence the siren the alarm is only cancelled by unsetting the system A rapidly flashing red light of a given segment indicates that the alarm is being or was triggered This continues to flash even after the alarm is unset The system will similarly signal the occurrence of an alarm triggered during your absence If this happens be very careful when entering and checking the premises or wait until the security guard arrives if your system is connected to an Alarm Receiving Centre The segment alarm indicator remains on until the system is set once again Alternatively it can be cleared by unsetting the system one more time With a keypad that has an LCD display the alarm indicator can be cleared from the main menu Clear alarm mem Indication E OPERATING THE JABLOTRON 100 SYSTEM OPERATING THE SYSTEM WITH A KEYFOB The installer must pro
6. USING THE SYSTEM KEYPAD Continuous red SET ON Flashes red ALARM ALARM MEMORY The system can be operated directly setting or unsetting the alarm and automation using two button segments on the keypad The segment buttons are clearly labelled and coloured using traffic light logic so that each segment s status is readily evident The segment can also be used to monitor its status e g garage door open or to control various automated devices for example heating or window shutters A segment can also be set up to call for help in an emergency as a Continuous orange PARTIALLY SET Continuous green je le le medical or panic alarm The maximum number of segments is twenty UNSET OFF Flashes green ENTRY DELAY Continuous green Continuous red UNSET OFF SET ON carace Flashes green z Flashes red ENTRY DELAY ALARM FULLY SET ALARM MEMORY Er lt lt ZF z Flashes red iu ALARM Jaa hl Continuous orange PARTIALLY SET Continuous green EVERYTHING OK Access module Flashes green CARD READER KEYPAD CONTROL Continuous orange FAULT OPERATING THE JABLOTRON 100 SYSTEM The various types of access modules and their combinations JABLOTRON CARD READER KEYPAD WITH CARD READER KEYPAD WITH DISPLAY AND CARD allows control of the system using the user can control the system by READER segments and touchless authorization segments and authorization using the user ca
7. and has two backlit buttons a green one on the left and a red or yellow one on the right A segment is used to easily and clearly operate a part of the system and simultaneously display its status using the colour indicators green when unset red when set and yellow when partially set The number of segments and their function are determined by the system installer RFID Card Tag The RFID card tag allows the user to operate the system and is used for touchless authorization by simply placing the card tag on to the keypad reader It replaces or complements numerical code entries The RFID card can be carried in a wallet The RFID tag can be attached to a key ring Section The alarm system can be divided into several smaller independently functioning parts called sections Each section can have its assigned detectors keypads as well as sirens users and their telephone numbers There can be up to 15 sections per system Programmable Output The security system can be used to switch on off or control other electrical devices or appliances This is done using programmable outputs that can be controlled by the user via text messages using the keypad etc or can be automated within the system following the system status alarm status failures etc Home Automation In addition to providing an intruder alarm system the JABLOTRON 100 offers a number of other features Among the most popular functions are electrical doors automat
8. ase see the J Link manual LOGGING INTO MyJABLOTRON WEB SMARTPHONE All system events can be viewed using the MyJABLOTRON web interface smartphone mi WHAT IS THE MyJABLOTRON WEB INTERFACE The MyJABLOTRON web interface is a unique service that allows on line access to JABLOTRON devices It allows end users to monitor and control the system The MyJABLOTRON web interface allows users to View the current system status gt Set unset the entire system or part of it gt Control programmable outputs gt View event history gt Send notifications to selected users via text messaging or e mail gt Capture high resolution images from camera detectors 640 x 480 gt Monitor current temperature or energy consumption including history overview in a graphic chart gt Take advantage of many other useful features Back House London 6H ALARM amp House Garage Office GLOSSARY OF TERMS 5 BUS Wireless Devices The main hub of the security system is its control panel This can communicate with all devices in two ways using a BUS i e using data cables within the guarded premises or part thereof or wirelessiy using radio frequencies BUS devices are powered from the control panel Wireless devices require batteries whose longevity depends on intensity of use Control Segment This is the control and signaling part of the access module keypad A segment contains a description of its function
9. blished using the same procedure co BLOCKING DISABLING THE SYSTEM BLOCKING DISABLING DETECTORS A detector can be temporarily disabled in a similar way that a user can be blocked A detector is disabled when its activation is temporarily not desirable for example a motion detector in a room with a pet or temporarily disabling the alarm siren Only the system administrator or service technician can disable a detector One method of disabling a detector is by choosing Settings gt Devices gt Bypass and selecting Yes on the LCD keypad Another option is to locally or remotely disable a detector through the J Link program by clicking on the detector in the Settings gt Diagnostics gt Disabled column A blocked disabled detector is marked with a yellow or red circle until it is turned back on using the same procedure DISABLING SECTIONS To shut off a part of the system temporarily individual sections can be disabled Disabled sections cannot be set e g to disable surveillance in part of a building under construction A section can be disabled locally or remotely through the J Link program by clicking on the section in the Settings gt Section gt Section disabled column A disabled section is marked with a red circle until it is turned back on using the same procedure DISABLING TIMERS To temporarily disable automated scheduled events in the system the timer can be turned off Disabling a scheduled event e g unset
10. bout this web interface please see the chapter What is the MyJABLOTRON Web Interface below MyJABLOTRON PROFI Version Depending on your country or region a web account is set up in MyJABLOTRON by an authorized JABLOTRON partner The login name is the user s e mail address The password can be changed at any time in the user settings Once logged into the account the system shows all active devices that can be monitored or controlled To operate the system the computer may prompt you to enter an authorization code at the beginning Subsequent actions will not require repeated authorization On the left vertical menu of the home page you can select to view either an on screen keypad or a complete system overview The on screen keypad allows operating the system by clicking on the segment buttons just as on the real keypad The Overview is arranged into horizontal tabs Sections Automation PG and tabs representing the detectors used in your system for example you may have Temperatures Camera detector or Electricity meters Tabs gt Sections allows to view and operate all the sections Vy JABLOTRON attona in the system gt Automation PG allows to view all the programmable system outputs To operate the programmable outputs using MyJABLOTRON the actual outputs must physically be turned on at least once after the MyJABLOTRON account is activated en getom gt Temperatures allows t
11. ed light switches using motion detectors and the remote control of appliances electrical heating garage doors gates entry barriers etc Panic Alarm When a user is in trouble and in need of urgent assistance the panic alarm can be triggered The panic alarm can be set up as a designated segment on the keypad a special code a panic button or as a speci fic combination of buttons on a keyfob If connected to a security centre triggering the panic alarm creates an immediate response vehicle dispatch that cannot be cancelled by phone Security Centre ARC An Alarm Receiving Centre a continuously manned security agency 24 7 is able to immediately react to information received from the guarded premises and respond with an appropriate action either with a direct presence at the guarded premises or by acting on the information received Notes For questions and further information contact your installer MLJ57105 N Il 8 com
12. er already has an account within the system any changes to the access rights will be reflected in that user s MyJABLOTRON dashboard Once logged into the account the system shows all active devices that can be monitored or controlled depending on the registered MyJABLOTRON version The LITE service package is limited in functionality and minimizes demands for data transfer LITE is based on the PROFI version with the following modifications Options LITE PROFI View the current system status v v lt Set unset the entire system or part of it y Control programmable outputs v View the event history Send notifications to selected users Operate the system through the on screen keypad Capture images from camera detectors View the photo gallery from detectors with cameras i Ss ME SS ENE 5 Monitor current and historic detector values such as temperature or energy consumption Communication with the secured premises is not continuous the system s current status comes up only once a connection is established The connection to the system takes about one minute OPERATING THE SYSTEM USING A SMARTPHONE lf a MyJABLOTRON user account is set up see previous section the alarm system can be monitored and controlled remotely using MyJABLOTRON for smart phones running either Android ver 2 4 or higher iPhone ver 7 or higher or Windows Mobile The application can be downloaded free of charge after logging
13. ew user an authorization code must be created or an RFID card tag must be assigned or any combination of these Furthermore access permissions rights must be set up what sections the user may operate what programmable outputs they can control and what type of authorization will be required EVENT HISTORY Cy lv JABLOTRON 2 mu The security system stores all performed operations and events ee setting unsetting alarms faults messages sent to users and 002222000 En ARC to the micro SD card in the system s control panel Each NEE a ea entry includes the date time start and end and source cause Se origin of the event Events are not deleted the entire system er history of the guarded premises is archived The memory has the en capacity to store several million records une i The different ways of browsing through the system s event history are described on the next page a Ca i EVENT HISTORY USING THE LCD KEYPAD Accessing the event history using the keypad requires user authorization Once authorized the available options based on user permissions are displayed by choosing Event Memory Records can be viewed from the most recent to the oldest USING J LINK AND A COMPUTER The system memory can be browsed using the J Link program Events can be viewed in small about 1 200 events or larger about 4 000 events batches The events can be filtered colour coded or saved into a file For more information ple
14. gram the keyfob into the system The keyfob can be linked to specific users thus avoiding text message notification to the user who is interacting with the system if notification parameters are set up in this way The keyfob can provide either two way communication confirming the execution of a command with a coloured indicator light or one way without any feedback Keyfobs control and indicate battery status and are equipped with optical indication the two way keyfob also with an acoustic indication The button functions are differentiated using the lock icon The closed lock icon sets the alarm the open lock icon unsets the alarm The solid and hollow circle icons serve to control one programmable device e g turn the lights on and off or two programmable devices e g a garage door and front door lock The buttons on the keyfob can be locked to prevent accidental pressing child safety lock For more detailed information see the specific keyfob manuals OPERATING THE SYSTEM USING A COMPUTER AND A USB CABLE J LINK The JABLOTRON 100 can be operated locally or remotely using a computer and an installed J Link program which can be used to manage users change codes card tags and phone numbers For local use J Link is available on the security system s disk drive When a computer is connected via USB to the control panel the system will automatically prompt you to install J Link If a keypad with at least one controllable
15. h user can change the second four digit code after the prefix and asterisk on the LCD keypad For guarded premises with a smaller number of users the prefix can be omitted In this case only a four digit code is required These types of codes can only be changed by the system administrator OPERATING THE JABLOTRON 100 SYSTEM CE Structure and description of the internal LCD keypad menu Clear alarm mem Indication Section Control Event memory Setting prevented Authorization by the code of the Faults in Service Technician system Administrator or Users Bypassed detectors System status Settings Display setting Allows the clearing of alarm indication in all sections for which the user has access rights Allows control of system sections that are not controllable by segments Allows detailed examination of the event memory Shows a list of triggered detectors preventing alarm setting Displays a list of all detectors signaling system faults Displays all blocked disabled detectors Shows a list of all triggered detectors by section Allows editing of users and devices only when USB is disconnected Allows adjustment of backlight brightness and display contrast OPERATING THE JABLOTRON 100 SYSTEM Alarm Setting le e e ____ e e e 1 PRESS 2 CONFIRM 3 DONE the segment button of the desired secti the command by authorization hold The command is executed
16. he default setting is changed Users and Their Access Rights Access Code Type Description Service Allows the user to program the system and add define users This code is given to the installation or security company that is responsible for correct system installation and configuration Administrator Allows the user access to the entire system including adding defining users This code allows access to all sections and is given to the owner or building property manager User Allows the user to operate designated system sections and programmable outputs This code is given to standard system users e g employees Set Allows the user to set designated system sections and programmable outputs This code is given for example to employees who do not have the right to unset the alarm PG only Allows the user to operate only programmable outputs This is intended for automated processes like opening doors for example Panic This code activates a silent panic alarm OPERATING THE JABLOTRON 100 SYSTEM ER Ways of Operating the JABLOTRON 100 On site System keypad System keyfob Computer using a USB cable and J Link program Remotely Telephone using the voice menu Computer via the MyJABLOTRON web interface Application in a smart phone Mobile using text messaging Computer via the internet using J Link Dialling in from an authorized telephone number only for operating programmable outputs
17. in MyJABLOTRON or from any Android Market AppStore etc Usernames and logins for MyJABLOTRON smart phone apps are identical to those for the MyJABLOTRON internet account OPERATING THE SYSTEM USING TEXT MESSAGING Individual sections and programmable outputs can be controlled using text messaging The text message to operate the system is CODE COMMAND The actual COMMANDs are predefined SET UNSET There may also be an additional numeric parameter that identifies the specific section The commands to control the outputs can be programmed by the system installer OPERATING THE JABLOTRON 100 SYSTEM Go For example you may choose SHUTTERS DOWN as your command to close the shutters on your win dows It is also possible to eliminate the need for the CODE before the command In such a case the com mand is simply authorized automatically when the system recognizes the user s phone number OPERATING THE SYSTEM REMOTELY USING A COMPUTER J LINK The JABLOTRON 100 system can be operated both remotely and locally on site by installing the J Link program on your computer Users can also be managed in this way change codes cards tags and phone numbers To operate the system remotely the program must be downloaded from the Downloads section of the www jablotron com website The registration number of the security system a 14 digit code and the telephone number of its SIM card is needed to connect to the system Remote access is initi
18. ly green to red This is indicated with a continuous an access code indicate an unset section tone and a flashing green button Note If there is an entry delay in part of or in the whole system the alarm can be unset simply by authorizing OPERATING THE JABLOTRON 100 SYSTEM Partial Alarm Setting e e e le e le e le CJC C 1 PRESS 2 CONFIRM 3 DONE the segment button of the desired secti the command by authorization hold The command is executed and the seg on The button will flash yellow a card or tag up to the reader or input ment button turns permanently yellow an access code to indicate a partially set section The system can also be partially set which allows only certain detectors to be triggered For example at night only doors and windows can be triggered while motion detectors within a home can be disabled To set an entire system all segments in which partial arming is enabled the button to set the system has to be pressed twice After the button is pressed once it flashes yellow after it is pressed a second time it flashes red If the system is already partially set showing a continuous yellow light the entire system can be set by pressing the yellow button Once authorized the entire system is set Partial setting can be set up in a way that authorization is not required Terminating a Triggered Alarm mk ME EFI gir 1 PRESS 2 CONFIRM 3 DONE 4 PRESS AND CONFIR
19. n control the system by RFID card tag either entering a code or the touchless segments and authorization using method RFID card tag or a combina either a code the touchless method tion of both for higher security RFID card tag both code and card tag for higher security or by authori zing and using the options available on the keypad s LCD display TT When unsetting the alarm using the segment buttons a user authorization is always required When setting the Aant OE u alarm and controlling automated processes using the un ua segment buttons user authorization is optional for each DISARM b segment u A user can be authorized by entering their assigned code or using their RFID card tag Each user can have one code and up to two RFID chips cards or tags JABLOTRON If the user wants to simultaneously control multiple segments authorization is required only once For example the user can at the same time set the house while unsetting the garage Recommended Touchless Chips JABLOTRON 100 Oasis Azor or other chips operating at 125 kHz EM For higher security the alarm system can be set up so that both the RFID chip and user code must be used to authorize THE KEYPAD AUTHORIZATION CODE can consist of up to seven digits a prefix one to three digits an asterisk which separates the prefix and main code and a four digit code Examples include 123 1234 or 1 1234 Eac
20. o view the current temperature for each thermometer installed Shows the history as well as graphs of the temperature changes over time gt Camera detector allows to take real time snapshots with any installed motion detector with camera or look at past photos taken with these detectors picture gallery 20 The bottom of the home page has an overview of the most recent system events MyJABLOTRON offers free notifications via text messaging e mail or push messages for selected system section events programmable outputs thermometers or meters These notifications can be set up in the Settings menu Each system can have only one administrator owner This user has the right to assign and remove access rights for other users The system will automatically create a new account for each new user that is set up by the administrator Notification of system access will be sent along with the password to the established user s e mail address login name If a user already has an account within the system any changes to the access rights will be reflected in that user s MyJABLOTRON dashboard OPERATING THE JABLOTRON 100 SYSTEM MyJABLOTRON LITE Version Depending on your country or region you may be able to open an account and or services in the MyJABLOTRON LITE internet application The first time user will be e mailed a password for the initial login The password can then be changed at any time in Settings If a us
21. segment is used with the system then it is possible to set unset the system in J Link using an on screen virtual keypad click on Keypad in the main menu OPERATING THE SYSTEM USING THE VOICE MENU The system can be controlled from a mobile or land line through a simple voice menu which guides the user through a series of options in the preset language To access the voice menu you just dial the alarm system s phone number Access to the voice menu can be enabled either to accept any incoming call without restriction or alternatively to only accept authorized phone num bers stored in the system In the first scenario the caller must enter their user authorization code using their phone pad in the second case further authori zation is not required Once the authorization process is complete the voice system will give an update of the current status of all sections assigned to the user The caller can then control these sections either individually or collectively using their phone pad and the available voice menu options The system default is set up to answer incoming calls after three rings approximately 15 seconds OPERATING THE JABLOTRON 100 SYSTEM OPERATING THE SYSTEM USING THE INTERNET AND MyJABLOTRON The JABLOTRON 100 can easily and conveniently be operated using your computer via the internet and the MyJABLOTRON web interface which is accessible from www myjablotron com For more information a
22. tart to flash by pressing Enter Then The RFID card tag must be placed on to the reader or the serial number must be manually entered After confirming by pressing Enter again the RFID card tag is added To delete an access card enter 0 into the serial number field After the changes are complete the change must be saved by selecting Save when the system prompts Save Settings The system administrator can add change and delete RFID cards tags from both the LCD keypad menu and J Link CHANGING A USERNAME OR PHONE NUMBER Each user can add modify or delete his phone number or change his name on the LCD keypad menu This can be done after authorization by selecting Settings gt Users gt User gt Phone or Name To make changes the user must be in edit mode This is done by pressing Enter on a respective row After making the changes they are confirmed by pressing Enter again To delete a phone number enter 0 into the phone number field After the changes are complete the change must be saved by selecting Save when the system prompts Save Settings The system administrator can add modify or delete user s phone number or change user s name from both the LCD keypad menu and J Link ADDING DELETING A USER Only the system administrator or service technician can add a new user or delete a user in the system This can be done only through the J Link program or the F Link program in the case of a technician When creating a n
23. ting the system from the night guarding at a predetermined time stops the execution of that event e g while on vacation A timer can be turned off locally or remotely through the J Link program by clicking on the section in the Settings gt Calendar gt Blocked column A disabled timer is marked with a red circle until it is turned back on using the same procedure I gt CUSTOMIZING THE SYSTEM CHANGING USER ACCESS CODE If the system is set up with prefixed codes the user can change his code from the LCD menu on the keypad The code can be changed on the LCD keypad after authorization by selecting Settings gt Users gt User gt Code To input a new code you must enter into edit mode the code will start to flash by pressing Enter enter the new code and confirm by pressing Enter again After completing the changes they must be confirmed by choosing Save when the system prompts Save Settings If the system is set up without prefixed codes only the system administrator can change the security codes The system administrator can make changes from both the LCD keypad menu and J Link CUSTOMIZING THE SYSTEM CET CHANGING DELETING OR ADDING AN RFID CARD TAG Each user can add modify or delete their RFID cards tags using the LCD keypad menu These changes are done after authorization by selecting Settings gt Users gt User gt Access card 1 or 2 To enter a new RFID card tag you must enter into edit mode access card 1 or 2 will s