1. waiting rooms retirement homes gyms Restaurants utensils tableware high chairs restrooms Public Restrooms toilets sinks doorknobs paper towel dispensers Traveling Hotels pillows bedding towels doorknobs bathrooms tables Airplanes seats headrests waiting areas trays headsets For Water Disinfection Use to disinfect water so that it is suitable for drinking and free of bacterial contaminants which can cause illness Nano UV Dual Scanner Model No NANO15 Two 2 Side Buttons Used To start Nano UV Dual Scanner LCD Screen Power Button Sensor Pins for Nano UV Water Disinfection Nano UV light wand Battery Compartment Battery Cap Protective Cover a How to use 1 Do not use this product or allow anyone to use this product until proper operating procedures and warnings are understood 2 Open the battery cover located on the top of the Nano UV Dual Scanner by pressing down on tab and pulling outward simultaneously Insert 4 AAA alkaline batteries included 3 Remove the protective cover located on the bottom of the Dual Scanner that protects the UV light NOTE Nano UV Dual Scanner will NOT turn on with protective cover in place 4 Press and hold the Power button for 3 seconds then release to power the Nano UV Dual Scanner NOTE The Nano UV light will not turn on until both gray buttons on the side are pressed simultaneou
2. Nano UV light may not be fully functional e To dispose of your Nano UV light contact your local dept of environmental protection or other authority for disposal guidelines Troubleshooting Why does the dual scanner not turn on 1 Make sure the AAA alkaline batteries are new and do not need to be replaced 2 Check the polarity of the batteries Make sure the battery cover is properly inserted 3 Remove the protective cover as it controls the main power switch 4 Press and hold the Power button for 3 seconds Why does the Nano UV light not turn on For Surface Disinfection Mode The Nano UV light will only turn on if it is in the Original position inside the chamber It will turn off automatically if the Nano UV light wand is flipped out For Water Disinfection Mode Check that the two sensor pins located on the black portion of the Nano UV light wand are completely immersed in water Why does the Nano UV light appear dim when immersed in water e Make sure that the Nano UV light wand is allowed to warm up for 30 seconds 3 times 10 seconds in Surface Disinfection mode before changing to Water Disinfection mode Then immerse the Nano UV light wand in the water e For cool water repeat the disinfection process multiple times This dual scanner is not intended for use in very cold water Can more than 500ml 2 cups of water be disinfected in 40 seconds Water disinfecti
3. seconds or press the Select button to stop the process and shift to Surface disinfection mode 8 The LCD screen on the top of _ the Nano UV Dual Scanner WZ will count down and display OK Jp 1 when the process has finished oom 9 Carefully flip the Nano UV f light wand back into the original OO position in the chamber for storage when water disinfection is complete When disinfection is finished The Nano UV Dual Scanner protective cover must be placed on the bottom of the Nano UV Dual Scanner to protect the Nano UV light and conserve batteries Auto off function If the Nano UV Dual Scanner is not used for more than 1 minute the Dual Scanner will turn off automatically to save power Prolonged Storage After prolonged storage press and hold the Power button until the LCD screen lights up and the Nano UV light wand will turn on after normal start up Sequence is completed Battery Indicator J When the battery voltage is low the LCD screen will read LO Replace R the batteries If the batteries are low the Nano UV Dual Scanner may not be effective in killing targeted germs on the surface in 10 seconds 99 9 or in water in 40 seconds 99 9 Battery Replacement 1 Remove battery cover located on the top of the Nano UV Dual Scanner by pressing down on the tab and pulling outward simultaneously 2 Remove the depleted batteries and re
4. NANO UV DUAL SCANNER Water amp Surface Disinfection User Manual You are the proud owner of the world s first compact NANO UV DUAL SCANNER Water amp Surface Disinfection Quite nlth Solutions Read these instructions before use The Nano UV Dual Scanner for water and surface disinfection safely kills 99 9 of targeted germs on surfaces within 10 seconds or in 500 mls 2 cups of water within 40 seconds This product is designed for powerful surface and water disinfection It produces sufficient energy to damage and alter DNA of all kinds of microorganisms For your safety do not expose your body or your eyes to this Nano UV light as it may be harmful Do not let children play with or use the Nano UV Dual Scanner Use the Nano UV Dual Scanner for disinfection of surfaces when at home in public places in the office or when traveling The Nano UV Dual Scanner can also be used for disinfecting drinking water when traveling in exotic or unfamiliar locations For water disinfection bY j For surface disinfection Use Nano UV Dual Scanner in Homes kitchens bathrooms butcher blocks remote controls counters bedding mattresses toilets shower floors footwear litter boxes pet beds Nurseries bottles pacifiers changing tables cribs toys Offices telephones restrooms cell phones keyboards furniture Public places hospitals clinics medical offices
5. Nano UV light bulb clean and avoid stains In case the Nano UV light bulb gets dirty wipe it with a soft cloth VERY GENTLY Caution Improper operation of the Nano UV Dual Scanner may cause injury Read and understand all warnings prior to operating e Do not use in any manner other than instructed in this User s Guide e Danger Nano Ultraviolet light can be harmful to skin and eyes e Do not use the Nano UV light on any part of the body e Do not look directly into the Nano UV light However it is safe to view Nano UV light through glass or plastic containers e Keep out of reach of children e Do not touch the Nano UV light bulb e Mercury Hazard Do not allow any impact to the Nano UV light bulb If the light bulb is cracked chipped or damaged do not operate In case the Nano UV light bulb breaks use a vacuum cleaner to clean it up Do not touch the mercury directly with bare hands especially pregnant women e The Nano UV light contains a small amount of mercury which may cause redness or irritation to the skin if exposed The mercury content meets RoHS requirements less than 0 5mg e Remove the batteries when not in use for long periods of time e Only use in clear water Do not use in ice water e Do not use as a light source e Operating the Nano UV Dual Scanner above 122 F 50 C and below 68 F 20 C for surfaces and below 59 F 15 C for water is not recommended and the
6. Testing Laboratories HK Opportunities for infection are abundant and virtually everywhere It is important to realize that use of the Nano UV Dual Scanner does not guarantee that the user will avoid illness To avoid microbial infection one must take a wide range of precautions Specifications UV Wavelength Multi wavelength including UV A amp UV C Dimensions 3 x 1 x 1 Weight 95g including batteries Power source 4 AAA Alkaline batteries Power 1 3W Operation temperature for surface 68 122 F 20 50 C Operation temperature for water 59 122 F 15 50 C Storage temperature 50 140 F 10 60 C Warranty e 90 day limited warranty against defects in material and workmanship at the time of its original purchase by the consumer e Never disassemble or tamper with the Nano UV Dual Scanner as it may cause injury or damage and the dual scanner warranty will be voided There are no consumer serviceable parts on the Nano UV Dual Scanner Any service attempts by unauthorized repair facilities could result in injury or damage to the Dual Scanner and will void all warranties The Nano UV Dual Scanner must be returned to Zadro Health Solutions Inc for repair Maintenance When the LCD screen does not come on simply replace the batteries Nano UV light bulb can be used for more than 6000 hours For the best disinfection performance always keep the
7. l you hear a click Do not touch the Nano UV light bulb 4 Place the Nano UV light wand in the water 2 Press Select button and choose Water on the LCD screen making sure the sensor pins located in the black potion of the wand are completely immersed in water NOTE For safety reasons Nano UV light will turn off and the disinfection process will stop if the two metal pins are not immersed in water 5 Press the two gray side buttons simultaneously and the Nano UV light wand will count down from 40 seconds NOTE The Nano UV light will not turn on until both gray buttons on the side are pressed simultaneously This also functions as a child safety feature 6 During the water disinfection process gently stir the water with the Nano UV light wand until the countdown is complete It takes 40 seconds to disinfect 500mls 2 cups of clear water NOTE The Dual Scanner is not water proof Only immerse to the level of the two 2 sensor pins NOTE Repeat the water disinfection process if larger water volumes greater than 500mls 2 cups are used or additional disinfection is desired NOTE The Nano UV light will turn off automatically if the sensor pins are removed from the water The disinfecting process and the countdown will continue when the sensor pins are immersed in the water again 7 Press both gray side buttons again to restart the water disinfection process for 40
8. on of more than 500mls 2 cups requires additional exposure to the Nano UV light You should repeat the disinfection process multiple times when greater than 500mls 2 cups of clear water is disinfected Why does the UV light still turn on when the tube is out of water Check the water remaining on the two Sensor Pins Simply blow away any water drops between the two pins nith Solutions 2011 Zadro Health Solutions Inc Printed in China Zadro Health Solutions Inc Innovative Ideas That Make Life Easier Huntington Beach CA 92649 714 892 9200 FAX 714 892 7477 E Mail Address zadrohs zadrohs com Website www zadrohs com Rev 08242011
9. place them with new batteries in the polarity direction indicated inside the battery chamber 3 Securely place battery cover cap back onto Dual Scanner Battery Caution e Use only fresh alkaline batteries of the required type and size e Do not mix old and new batteries different types of batteries or rechargeable batteries of different capacities e The batteries may explode if mistreated Do not attempt to recharge or disassemble the batteries e Depleted batteries are to be removed from the Dual Scanner immediately e Dispose of the old batteries properly and according to your local regulations e Ensure that batteries are kept out of reach of young children Comparison of Nano UV Disinfection Light vs Standard UV Light Type Nano UV Light Multi Wavelength Single Wavelength UV A amp UV C UV C 185 365nm 253 7nm ower Standard UV Light Time of Surface 10 seconds Surface 1 hour Disinfection Water 40 seconds Water Not Available Speed of Bulky amp Heavy Limited to commercial applications and environments Small Handy amp User Friendly Use in home and living environments Certificates amp Testing Laboratories While carefully controlled microbiological testing of the Nano UV Dual Scanner has been conducted use of the Nano UV Dual Scanner in the field may produce results that vary from our laboratory test data 1 Intertek ETL Testing Laboratories USA 2 SGS Ltd
10. sly This also functions as a child safety feature 2 Allow the Nano UV light to warm up for at least 30 seconds 3 times 10 seconds before using SURFACE ar 3 Hold the Nano UV Dual Scanner between to 1 inches from the surface you want to scan For Disinfecting Surfaces 1 Press Select button and choose Surface on the LCD screen 4 Simultaneously press the two gray buttons located on the sides and the Nano UV light will come on for 10 seconds NOTE The Nano UV light will not turn on until both gray buttons on the side are pressed simultaneously This also functions as a child safety feature 5 For highly contaminated areas hold the light close to the object 4 and repeat scan 2 to 3 times 6 For larger areas place the light between and 172 and move the Dual Scanner slowly over the area until the entire surface has been scanned 7 The closer the Dual Scanner is to the object the more effective the disinfection TA 8 The LCD screen will count down from 10 to 1 seconds and will display OK when finished SURFACE wees E For Disinfecting Water 1 Make sure that the Nano UV light wand is allowed to warm up for 30 seconds 3 times 10 seconds in Surface Disinfection mode before changing to Water Disinfection mode 3 Holding the bottom black portion of the Nano UV light carefully flip we the Nano UV light wand out of the chamber unti

Download Pdf Manuals

image

Related Search

Related Contents

INSTALLATION/USER MANUAL - Newall Electronics Inc.  Bedienungsanleitung  9. Using the Setup Program  Zotac ZT-88XE760-FPP GeForce 8800 GTX graphics card  Descarga el manual de instalación en pdf  unidad multimedia de autoaprendizaje sobre el - e  eMedNY Subsystem User Manual  [大宮東公民館]総括表(PDF形式:11KB)  商品企画書 商品名  8845A/8846A  