Thank you for purchasing an Escali Digital Scale. Please read the
Contents
1. Wait for approximately 4 seconds as the scale performs internal calibration 5 The display will show F to indicate successful calibration or E if calibration failed 6 Press the Tare key to return the scale to weight mode Auto Shut Off Your scale turns off after 4 minutes of non use Additional Information 1 Make sure your scale is at room temperature and on a stable horizontal surface free of vibration 2 This scale is not waterproof Do not expose to moisture 3 As this scale is a precision instrument it must be handled with extreme care Avoid rough treatment shaking and vibration 4 Do not disassemble this scale or the warranty will be void 5 The display value may be affected by electromagnetic disturbances such as operating near a radio If this occurs move the device that is causing the disturbance and turn the scale off and restart Warranty Manufacturer s one year warranty see www escali com for full details Escali s liability is limited to two 2 times the cost of the product AC DC adapter Warning To prevent damage only use a 9V adapter with a negative tip Copyright Escali LLC 2011 Auto Shut Off Your scale turns off after 4 minutes of non use Additional Information 1 Make sure your scale is at room temperature and on a stable horizontal surface free of vibration 2 This scale is not waterproof Do not expose to moisture 3 As this scale is a precision instrument it must be han
2. 5 The display will show F to indicate successful calibration or E if calibration failed 6 Press the Tare key to return the scale to weight mode Do not place overweight items on scale Weighing items over the maximum weight capacity will cause an O Ld to display Immediately remove overweight items to avoid causing damage to your scale Memory function 1 Press the ON MEM button to save the weight to memory 2 Repeat this step to save an additional item Each time you save an item to memory the scale will display the cumulative weight 3 Press ON MEM again to start your next item to memory 4 Press the TARE button to clear the memory Counting Feature 1 Select your count sample with the MODE CAL button You can choose a sample of 5 10 20 or 50 2 Put the corresponding sample count on the panel and wait 2 seconds 3 Press the TARE button and the scale will show the quantity on the panel 4 When adding or taking away pieces the scale will tell you the quantity on the panel Calibration Feature For best results calibrate your scale at regular intervals 1 Turn the scale on and wait till it displays zero 2 Press and hold the MODE CAL key till a weight number appears on the display 3 Depending on the model your scale will need the following calibration weight L125 100 gram L600 500 gram L3000 2000 gram or L6000 4000 gram 4 Gently place the calibration weight in the center of the panel
3. Thank you for purchasing an Escali Digital Scale Please read the following operation information to ensure the proper function of your new scale How to weigh 1 Press the ON MEM button 2 0 will show on display 3 Place item slowly on the panel and wait till display shows the weight Selecting the Weight Mode You may switch to other weighing units during use by pushing the MODE button Weight modes include gn grains g grams oz ounces dwt pennyweight ozt troy ounces or ct carats How to use the Hold feature This feature allows you to see the weight of an item after you have removed the item from the panel 1 Press the Hold button 2 Place item slowly on the panel The scale will beep twice when the weight has been captured 3 Remove the item and its weight will display for 5 seconds How to use the Tare feature This feature allows you to obtain the exact weigh of an item in a container by subtracting the weight of the container 1 Place the container without the item slowly on the panel 2 Press the Tare button The weight of the container will be removed The display value will reset to 0 3 Slowly add the item to the container The display will show the weight of the item only 4 You may continue to determine the weight of each additional item as they are added by repeating steps 2 amp 3 How to clear Tare Feature Press the Tare button aga
4. dled with extreme care Avoid rough treatment shaking and vibration 4 Do not disassemble this scale or the warranty will be void 5 The display value may be affected by electromagnetic disturbances such as operating near a radio If this occurs move the device that is causing the disturbance and turn the scale off and restart Warranty Manufacturer s one year warranty see www escali com for full details Escali s liability is limited to two 2 times the cost of the product AC DC adapter Warning To prevent damage only use a 9V adapter with a negative tip Copyright Escali LLC 2011 Escali User Manual L Series Professional Laboratory Scale Capacity L125 125 gram L600 600 gram L3000 3000 gram L6000 6000 gram WWW amp 4ealz com Escali User Manual L Series Professional Laboratory Scale Capacity L125 125 gram L600 600 gram L3000 3000 gram L6000 6000 gram WWW amp 4ealz com
5. in and the scale will return to 0 Thank you for purchasing an Escali Digital Scale Please read the following operation information to ensure the proper function of your new scale How to weigh 1 Press the ON MEM button 2 0 will show on display 3 Place item slowly on the panel and wait till display shows the weight Selecting the Weight Mode You may switch to other weighing units during use by pushing the MODE button Weight modes include gn grains g grams oz ounces dwt pennyweight ozt troy ounces or ct carats How to use the Hold feature This feature allows you to see the weight of an item after you have removed the item from the panel 1 Press the Hold button 2 Place item slowly on the panel The scale will beep twice when the weight has been captured 3 Remove the item and its weight will display for 5 seconds How to use the Tare feature This feature allows you to obtain the exact weigh of an item ina container by subtracting the weight of the container 1 Place the container without the item slowly on the panel 2 Press the Tare button The weight of the container will be removed The display value will reset to O 3 Slowly add the item to the container The display will show the weight of the item only 4 You may continue to determine the weight of each additional item as they are added by repeating steps 2 amp 3 How to clear Tare Featu
6. re Press the Tare button again and the scale will return to 0 Do not place overweight items on scale Weighing items over the maximum weight capacity will cause an O Ld to display Immediately remove overweight items to avoid causing damage to your scale Memory function 1 Press the ON MEM button to save the weight to memory 2 Repeat this step to save an additional item Each time you save an item to memory the scale will display the cumulative weight 3 Press ON MEM again to start your next item to memory 4 Press the TARE button to clear the memory Counting Feature 1 Select your count sample with the MODE CAL button You can choose a sample of 5 10 20 or 50 2 Put the corresponding sample count on the panel and wait 2 seconds 3 Press the TARE button and the scale will show the quantity on the panel 4 When adding or taking away pieces the scale will tell you the quantity on the panel Calibration Feature For best results calibrate your scale at regular intervals 1 Turn the scale on and wait till it displays zero 2 Press and hold the MODE CAL key till a weight number appears on the display 3 Depending on the model your scale will need the following calibration weight L125 100 gram L600 500 gram L3000 2000 gram or L6000 4000 gram 4 Gently place the calibration weight in the center of the panel Wait for approximately 4 seconds as the scale performs internal calibration