Home

migan - microSYST Systemelectronic GmbH

image

Contents

1. Display type Character heights Number of digits Number of lines Display colour Operating voltage View Interface Displayable characters Labelling Housing Housing colour Mounting Protection Operating temp Storage temp Notes for the start up 7 segment SMD LED Indoor use 60 100 150 200 250 mm Outdoor use 100 200 300 mm Standard 1 12 Alternative 1 15 Standard 1 line multiple lines on request Standard red other colours on request 230 VAC 50 Hz 110 VAC 60 Hz or 24 VDC 20 Single sided to four sided Interbus See corresponding chapter On request Industrial version powder coated aluminum RAL 7016 anthracite Articulated arm angle bracket hanging on chain or mounting frame See chapter Device Configuration See chapter Device Configuration 25 70 C e When putting on the power supply the following sequence has to be ob served o Connect the power supply cable to the display o Connect the power supply cable to the power supply e When disconnecting the power supply the following sequence has to be observed o Disconnect the power supply cable from the power supply o Disconnect the power supply cable from the display Page 5 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 info microsyst de www microsyst de microSYST l N migan Large Format Num
2. Bit 3 Digit 2 Bit 3 Digit 7 Bit 3 Digit 12 Bit 4 Digit 1 Bit 4 Digit 6 Bit 4 Digit 11 Bit 5 State 0 Bit 5 State 0 Bit 5 State 0 Bit 6 State 1 Bit 6 State 1 Bit 6 State 1 Bit 7 State 0 Bit 7 State 0 Bit 7 State 0 The point bytes must be sent even if no decimal point shall be shown In this case the point bytes PB1 to PB3 have the value 40 because of the static values of the bits 5 to 6 Page 10 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 info microsyst de www microsyst de microSYST i wh migan Gass Large Format Numeric LED Display with InterBus Interface 3 6 1 Interbus Frame for controlling the Display Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Toggle byte Data byte 1 Data byte 2 Databyte3 Databyte 4 Data byte 5 Databyte6 Data byte 7 Toggle byte The interface at the large format display is driven with the first byte of output data toggle byte TB The toggle byte is saved to intermediate memory immediately after the InterBus interface has been initialised first of all it must be 0 and is then always compared with the respectively current content of the first byte of output data As soon as it s value is changed subsequent output data are evaluated and interface data are transmitted to the large format display if appropriate The only evaluation criterion is a change of con tent the
3. info microsyst de www microsyst de l N migan microSYST Large Format Numeric LED Display with InterBus Interface 5 2 Declaration of Conformity EG Konformit tserkl rung Declaration of EC Conformity Produktbezeichnung migan Interbus Product name Produktbeschreibung Numerische LED Gro anzeige mit InterBus Interface Product description Large Format Numeric LED Display with InterBus Interface Hersteller microSYST Systemelectronic GmbH Manufacturer Albert Einstein Stra e 7 92637 Weiden Das bezeichnete Produkt stimmt mit der folgenden Europ ischen Richtlinie berein We herewith confirm that the above men tioned product meets the requirements of the following standard Die bereinstimmung des bezeichneten Produktes mit den Vorschriften der Richtli nie wird nachgewiesen durch die vollst n dige Einhaltung folgender Normen The correspondence of the above mentioned product with these requirements is proved by the fact that these products meet with the fol lowing single standards Nummer Bezeichnung Europ ische Norm Elektromagnetische 2004 108 EG Vertr glichkeit EMV EN61000 6 2 2006 EN61000 6 4 2007 Weiden den 27 03 2013 pe Ae Leiter operatives Gesch ft COO Prokurist Authorized Signatory Page 18 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 info microsyst de www microsyst d
4. 1 39166 10 info microsyst de www microsyst de microSYST l N migan Large Format Numeric LED Display with InterBus Interface 3 4 Control via the InterBus Interface Data received by the InterBus out words are stored to intermediate memory processed and transmitted to the large format display After the frame has been transmitted the frame data are mirrored via the In terBus as a response in words Interbus SUPI 3 Interbus Interface 4 IB Out Words id 4 IB In Words a 4 IB Out Words After transmission by the UART UART Serial transmission to large format display 3 4 1 User Data IB Output The large format alphanumeric display utilises 4 IB output words These are used for transmission of user data which are required for control of the large format display 3 4 2 User Data IB Input The large format numeric display utilises 4 IB input words These are used as a response to user data which have been transmitted to the large format display After transmission of each frame the IB data which have just been transferred to the large format LED display are mirrored in response to the in words Page 8 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 info microsyst de www microsyst de microSYST i wh migan Gass Large Format Numeric LED Display with InterBus Interface 3 5 Standard Transmission Frame IB Outp
5. 4 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 info microsyst de www microsyst de microSYST l N migan Large Format Numeric LED Display with InterBus Interface 4 1 InterBus Interface LEDS LED7 LED6 LEDS 30 o o o 0 8 0 o 6 IB DUT Controller InterBus Interface DIP Switches CEES 7 e ieni HEEmMEENEmE Lene 123435 6 7 10 fests ala ir le n3 1 1 LEDs eS 1 RUN blinks at CPU activity green approx 2 Hz ERROR UART UART communication red 3 BUS On cyclic IB data transmission ellow 4 SUPI 3 On normal operation after RESET green Watchdog n Error at the IB module ale red 6 BA bus activity Dr no bus activity since at least 630 ms Watchdog expired green OK and no Interbus RESET Pe P red Interface disengaged Page 15 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 info microsyst de www microsyst de microSYST l N migan Large Format Numeric LED Display with InterBus Interface DIP Switches 9 notcomneted DIP6 specifies which frame type is used for the controlling see chap ters 3 5 and 3 6 The remaining switches are set by default and must not be changed Page 16 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Tel 49 961 39166 0 F
6. actual content itself is irrelevant The following must be observed in order to transmit a frame to the large format display e The frame at the large format LED display is subdivided into blocks of 7 bytes each which are transmitted one after the other e The InterBus interface accepts output data transmitted by the IB master 7 bytes as soon as the toggle byte has been changed As soon as transmission of the 7 bytes of frame data to the large format display is concluded the output data transmitted by the IB master are mirrored to the input data at the IB master 8 bytes e The next block cannot be transmitted until input and output data are identical the comparison of the toggle byte is sufficiently e If the last block of the protocol requires less than 7 bytes the unused bytes must be set to 00h they are not sent Page 11 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 info microsyst de www microsyst de microSYST l N migan Large Format Numeric LED Display with InterBus Interface 3 6 2 Example Display the numbers 123456 Transmission of block 1 1 2 3 4 5 6 7 8 toggle STX ADRH ADRL point byte1 point byte2 point byte3 display byte data 3C H 304 314 40 H 40H 404 31H First change bytes 2 through 8 then change byte 1 Do not begin with transmission of block 2 until response has been re ceived 8 bytes of output data are mir
7. ax 49 961 39166 10 info microsyst de www microsyst de microSYST l N migan Large Format Numeric LED Display with InterBus Interface 5 Appendix 5 1 Maintenance and Care Please observe the following instructions e Make sure that the housing can be opened for adjustment and maintenance even after the display has been installed Allow for ad equate clearance at the back front and top of the display unit in or der to follow for sufficient ventilation if vent slots are included e Display quality is impaired by direct illumination with bright light sources and or direct sunlight e The display must be switched off before cleaning e Protect the display from excessive humidity extreme vibration di rect sunlight and extreme temperatures Non observance may lead to malfunctioning or destruction of the device Under certain cir cumstances electrical shock fire and explosion may occur as well Information concerning allowable ambient conditions including rec ommended temperature ranges can be found in the chapter enti tled Technical Data e The display may not be placed into service if the device and or the power cable are known to be damaged e Do not attempt to repair the device yourself The guarantee is ren dered null and void if the device is tampered with by unauthorised persons Page 17 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10
8. croSYST Systemelectronic GmbH in current version apply as well Page 19 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 info microsyst de www microsyst de microSYST l N migan Large Format Numeric LED Display with InterBus Interface 5 4 Versions Overview 07 10 00 06 20 01 10 04 01 New InterBus Interface HE194 MO1 Kreuzer 12 12 01 Kreuzer Character height changed 12 19 01 Kreuzer Housing dimensions changed 02 06 02 Kreuzer Device configuration IB ID 06 11 02 Kreuzer Example changed 12 17 02 Kreuzer New logo 10 20 03 Kreuzer Notes for the start up 11 9 05 Kreuzer Additional frame type selectable via DIP switch 1 28 11 Description migan AW added 3 27 13 Company address declaration of conformity warranty 10 17 13 Logo 01 20 15 SMD LEDs Certified per DIN EN ISO 9001 Page 20 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 info microsyst de www microsyst de
9. e microSYST l N migan Large Format Numeric LED Display with InterBus Interface 5 3 Warranty Liability For the product liability is assumed for defects which existed at the de livery date according to our General Terms and Conditions Technically changes as well as errors are excepted A claim for delivery of a new product does not exist The buyer has to check the received product immediately and indicate evident defects at the latest 24 hours after detection Non observance of notification requirements is equated with acceptance of the defect Not immediately visible defects have to be indicated immediately after their perception too Generally defects and their symptoms must be described as accurately as possible in order to allow for reproducibility and elimination The buy er must provide for access to the relevant device and all required and or useful information at no charge and must make all of the required data and machine time available free of charge The guarantee does not cover defects which result from non observance of the prescribed conditions of use or from improper han dling If the device has been placed at the disposal of the buyer for test pur poses and has been purchased subsequent to such testing both parties agree that the product is to be considered used and that it has been purchased as is No guarantee claims may be made in such cases The General Terms and Conditions of mi
10. eric LED Display with InterBus Interface 3 2 Device Configuration Type L for inside use L for outside use Character height 60mm 175mm 1100 mm 1120 mm 1150 mm 180 mm C 200 mm _ 250 mm Number of lines Number of digits per line Display colour L red L green _ yellow LI white L blue View L single sided L double sided L four sided Operating voltage L 230 VAC 50 Hz L 110 VAC 60 Hz L 24 VDC Protection C 1P40 C IP54 LC IP65 C IP Operating temperature L 0 to 50 C L 25 to 50 C O C Housing dimensions X X mm Housing Material L Aluminum profile LI Stainless steel LI Sheet metal Interface Interbus InterBus ID 03H fixed Page 6 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 info microsyst de www microsyst de microSYST l N migan Large Format Numeric LED Display with InterBus Interface 3 3 Device or System Start Up The large format numeric LED display performs internal memory and function tests while powering up The following data appear at the large format display Baud rate Parity Data bits Stop bits 12345 Address The displayed values are of no significance for the InterBus user This setting influences control via the RS 485 serial interface internal Page 7 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Tel 49 961 39166 0 Fax 49 96
11. fferent character heights and numbers of digits Thus integration into existing equipment or systems is easy and simple Display Functions e Data transmission InterBus e Simple parameter setting and initial start up e Variable size thanks to modular display design Important Note The display provides two different types of transmission frames selectable with DIP switches As of 11 09 2005 a new simpler frame type is adjusted at the delivery by de fault see chapter Standard Transmission Frame If the former transmission frame is still required see chapter Alternative Transmission Frame the internal DIP switches must be adjusted according to this see chapter InterBus Interface Page 3 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 info microsyst de www microsyst de microSYST l N migan Large Format Numeric LED Display with InterBus Interface 2 System Overview Schematic diagram of the display unit at the interface IB Master InterBus Large Format Numeric LED Display InterBus Interface O Modul O Modul Page 4 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 info microsyst de www microsyst de l N migan microSYST Large Format Numeric LED Display with InterBus Interface 3 Technical Data 3 1 Overall Specification
12. microSYST A migan Large Format Numeric LED Display with InterBus Interface User Manual microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 info microsyst de www microsyst de microSYST l N migan Large Format Numeric LED Display with InterBus Interface Index 1 GENERAL 3 2 SYSTEM OVERVIEW 4 3 TECHNICAL DATA 5 3 1 Overall Specification 5 3 2 Device Configuration 6 3 3 Device or System Start Up 7 3 4 Control via the InterBus Interface 8 3 4 1 User Data IB Output 8 3 4 2 User Data IB Input 8 3 5 Standard Transmission Frame IB Output 9 3 5 1 Example 9 3 6 Alternative Transmission Frame IB Output 10 3 6 1 Interbus Frame for controlling the Display 11 3 6 2 Example 12 3 7 Response Frame IB Input 8 Bytes 12 4 CONNECTOR PIN ASSIGNMENTS 13 4 1 InterBus Interface 15 5 APPENDIX 17 5 1 Maintenance and Care 17 5 2 Declaration of Conformity 18 5 3 Warranty Liability 19 5 4 Versions Overview 20 Page 2 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 info microsyst de www microsyst de microSYST l N migan Large Format Numeric LED Display with InterBus Interface 1 General The large display numeric LED can be used universally for displaying production data or as an information board The modular design allows for cost effective models of various sizes and with di
13. rored to the input data Transmission of block 2 1 2 3 4 5 6 7 8 display display display display display byte data data data data data 324 33 H 344 35H 36 H 3E Hu 004 First change bytes 2 through 8 then change byte 1 3 7 Response Frame IB Input 8 Bytes Once the display has been updated these bytes are identical to the IB output bytes The IB input bytes needn t be evaluated by the Interbus Master PLC Page 12 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 info microsyst de www microsyst de microSYST l N migan Large Format Numeric LED Display with InterBus Interface 4 Connector Pin Assignments IB IN Interbus IN 9 Pin Sub D Plug Connector n c fe y O DO inverted 7 DI inverted ER EN o ne O n C 9 fn IB OUT Interbus OUT 9 Pin Sub D Socket Connector 6 DO invered 8 n c Doo nn 9 Termination RBST Termination If a further device is connected pin 5 must be bridged to pin 9 If no further device is connected pin 5 is not bridged to pin 9 Page 13 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 info microsyst de www microsyst de microSYST l N migan Large Format Numeric LED Display with InterBus Interface Power Connector 230 VAC Power Connector 24 VDC optional Page 1
14. ut For activation of this frame type see chapter 4 1 Byte4 Digit 1 2 Digit 3 4 Digit 5 6 Digit 7 8 Digit 9 10 Digit 11 12 see coding char option 1 option 2 Coding Char Coding Option 1 Coding Option 2 T On Display activation 1 ON 0 OFF 3 5 1 Example The following chars shall be displayed at a 6 digit display 1234 56 Frame HEX coded 124 34H 56H 00H 00H OOH 08H 80H Page 9 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 info microsyst de www microsyst de microSYST l N migan Large Format Numeric LED Display with InterBus Interface 3 6 Alternative Transmission Frame IB Output For activation of this frame type see chapter 4 1 byte 1 byte 2 byte 3 byte4 byte 5 byte 6 n 1 STX ADRH ADRL PB1 PB2 PB3 1 15 chars ETX Bali lal ad ea number of digits SCH 30H 31H see coding of point bytes ASCII code of the 3E H char which shall be displayed Coding of Point Bytes PB As soon as the regarding bit has the value 0 the decimal point is shown at the relating display digit Digit 1 is always the first digit of the device located at the left side PB1 Point PB2 Point PB3 Point Position Position Position Bit 0 Digit 5 Bit 0 Digit 10 Bit 0 Digit 15 Bit 1 Digit 4 Bit 1 Digit 9 Bit 1 Digit 14 Bit 2 Digit 3 Bit 2 Digit 8 Bit 2 Digit 13