Home

1747-IN019F-EN-P SLC™ 5/05 Processors

image

Contents

1. ATTENTION Do not remove the processor from the SLC 500 chassis until all power is removed from the SLC 500 power supply SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade 17 Publication 1747 IN019F EN P August 2008 The AB_SNMP BOOTP Server Running dialog box may appear The Update Status dialog box appears If the update was successful the status text box is green and has an appropriate message If the update was not successful the status text box is red and has an appropriate message 18 SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade Publication 1747 IN019F EN P August 2008 27 Click OK and you are returned to the Welcome to ControlFLASH dialog box 28 You may either continue upgrading additional SLC 5 05 processors by clicking Next or you may exit the program by clicking Cancel If you click Cancel you are asked to verify that you want to end the update session SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade 19 Publication 1747 IN019F EN P August 2008 After Successfully Updating Your SLC 5 05 Processor 1 Remove power from the SLC 500 power supply and remove the processor from the chassis 2 Apply the enclosed operating system upgrade label to the SLC 5 05 processor nameplate 3 Re insert the processor into the chassis and apply power 4 Restore your program to the processor ControlFLASH Error Messages There are 3 e
2. AL NO PROC REV UL SA PROCESSOR UNIT MADE IN USA LISTED IND CONT EQ FOR HAZ LOC A196 CLASS 1 GROUPS A B C AND D DIV 2 FAC OPERATING TEMPERATURE CODE T3C 1 3 PROTECT PROGRAM J4 OS SER FRN OPERATING SYSTEM INFO PLACE FRN UPGRADE LABEL HERE WHITE RED BATTERY CURRENT REQUIREMENTS 1A 5 VDC 200mA 24 VDC Daughter Card Mother Board Jumper J4 SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade 7 Publication 1747 IN019F EN P August 2008 6 Verify that the SLC 5 05 processor s key switch is in the PROG or REM PROG RUN LED indicator not illuminated mode The Welcome to ControlFLASH dialog box appears 7 Click Next 8 Select the appropriate catalog number from the Catalog Number dialog box and click Next For Series C Processors select between the catalog numbers followed by a C 8 SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade Publication 1747 IN019F EN P August 2008 The AB_SNMP DLL Enter IP Address dialog box appears 9 Type in the IP address for the processor 10 Click the Get Info button If the IP address was previously configured into the processor go to step 12 The AB_SNMP BOOTP Server dialog box appears indicating that this IP address has not been configured into the processor IMPORTANT Use the IP address that was noted in step 2 of the Prior to Running Con
3. Place the SLC 5 05 processor into PROG mode 2 Ensure that DHCP is not selected 3 Restart the firmware upgrade process at the beginning of the Use ControlFLASH section If the error occurs again power cycle the SLC 5 05 processor and restart the firmware upgrade process 22 SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade Publication 1747 IN019F EN P August 2008 Failed to Receive Initial TFTP Request from Target The following dialog boxes appear in the sequence shown when this error occurs To clear this error 1 Connect the processor s Ethernet port directly to the PC Ethernet port using a crossover cable or disable or uninstall any firewall VPN or virus protection software running on the PC 2 Power cycle the processor 3 Restart the firmware upgrade process SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade 23 Publication 1747 IN019F EN P August 2008 Notes Publication 1747 IN019F EN P August 2008 PN 40071 111 01 6 Supersedes Publication 1747 IN019E EN P June 2008 Copyright 2008 Rockwell Automation Inc All rights reserved Printed in Singapore Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products At http support rockwellautomation com you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service p
4. Publication 1747 IN019F EN P August 2008 Installation Instructions SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade Catalog Number 1747 DU501 Inside Page Important User Information 2 For More Information 3 System Requirements 3 Install ControlFLASH 3 Prior to Running ControlFLASH 4 Return the SLC 5 05 Processors to Initial Factory Conditions 5 Use ControlFLASH 6 After Successfully Updating Your SLC 5 05 Processor 19 ControlFLASH Error Messages 19 2 SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade Publication 1747 IN019F EN P August 2008 Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment Safety Guidelines for the Application Installation and Maint
5. acks and a MySupport feature that you can customize to make the best use of these tools For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit At http support rockwellautomation com Installation Assistance If you experience a problem with a hardware module within the first 24 hours of installation please review the information that s contained in this manual You can also contact a special Customer Support number for initial help in getting your module up and running New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures Allen Bradley Rockwell Automation SLC SLC 500 RSLogix 500 ControlFLASH and TechConnect are trademarks of Rockwell Automation Inc Trademarks not belonging to Rockwell Automation are property of their respective companies United States 1 440 646 3434 Monday Friday 8am 5pm EST Outside United States Please contact your local Rockwell Automation representative for any technical support issues United States Contact your distributor You must provide a Customer Support case number see phone number above to o
6. btain one to your distributor in order to complete the return process Outside United States Please contact your local Rockwell Automation representative for return procedure
7. e Channel Configuration dialog box select the Chan 1 System tab If BOOTP Enable is selected and the IP Address is 0 0 0 0 then note the Ethernet Hardware Address located on the Ethernet Daughtercard of the 5 05 processor which begins with 00 00 BC IMPORTANT The user program is cleared as part of the operating system upgrade process You must restore your program after successfully loading the operating system upgrade IMPORTANT Refer to the following Rockwell Automation publications for further information on the Ethernet Communication Protocol SLC 500 Instruction Set Reference Manual publication number 1747 RM001 SLC 500 Modular Hardware Style User Manual publication number 1747 UM011 IMPORTANT If you are not sure whether an IP address is assigned or cannot determine what the IP address is return the 5 05 processor to initial factory conditions SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade 5 Publication 1747 IN019F EN P August 2008 Return the SLC 5 05 Processors to Initial Factory Conditions To return the processor to initial factory conditions 1 Remove power from the SLC 500 power supply 2 Remove the processor from the chassis 3 Disconnect the battery by removing the battery connector from its socket 4 Locate the VBB and GND connections on the back of the motherboard 5 Place a small bladed screwdriver across the VBB and GND connections and hold for 60 seco
8. enance of Solid State Controls Publication SGI 1 1 available from your local Rockwell Automation sales office or online at http www ab com manuals gi describes some important differences between solid state equipment and hard wired electromechanical devices Because of this difference and also because of the wide variety of uses for solid state equipment all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable In no event will Rockwell Automation Inc be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment The examples and diagrams in this manual are included solely for illustrative purposes Because of the many variables and requirements associated with any particular installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect to use of information circuits equipment or software described in this manual Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automation Inc is prohibited Throughout this manual when necessary we use notes to make you aware of safety considerations WARNING Identifies information about practices or circumstances that can cause an explosion in a hazardous environmen
9. izard appears to guide you through the installation process If a ControlFLASH directory does not already exist one is created in your Program Files directory For Refer to this Document Pub No A more detailed description on how to install and use your SLC 500 Modular Hardware Style Control System SLC 500 Modular Hardware Style User Manual 1747 UM011 A more detailed description on how to install your SLC 500 Modular Processors SLC 5 03 SLC 5 04 and SLC 5 05 Modular Processors Installation Instructions 1747 IN009 A more detailed description on ControlFLASH installation ControlFLASH Firmware Upgrade Kit Quick Start 1756 QS105 IMPORTANT If an error is encountered during installation uninstall the previous ControlFLASH firmware from the computer and try again 4 SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade Publication 1747 IN019F EN P August 2008 Prior to Running ControlFLASH For OS501 Series C FRN 9 and later the SNMP Server must be enabled for the upgrade to occur The ability to disable the SNMP Server that was added in Series C FRN 9 and later requires RSLogix 500 version 6 30 or higher 1 Save the current SLC 5 05 processor program 2 Note the assigned IP address of the SLC 5 05 processor When updating the processor use BOOTP or fixed IP address not DHCP The IP address may be read from the processor when you are online with RSLogix 500 software in th
10. nds This returns the processor to the initial factory conditions IMPORTANT If you return the processor to the initial factory conditions the user program and communication configurations are returned to their default settings ATTENTION Do not remove the processor from the SLC 500 chassis until all power is removed from the SLC 500 power supply GND VBB 6 SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade Publication 1747 IN019F EN P August 2008 Use ControlFLASH 1 Launch the ControlFLASH application under Programs gt Flash Programming Tools 2 Verify that the J4 jumper of the SLC 5 05 processor being upgraded is set to Protect The daughtercard firmware can only be updated when the J4 jumper is set to Protect 3 Insert the SLC 5 05 processor into an SLC chassis 4 Attach an Ethernet cable to the processor from your computer or a hub 5 Apply power to the chassis ATTENTION Do not interrupt the flash procedure Once you have begun to download the firmware for either the daughtercard step 18 or the motherboard step 24 the SLC 5 05 is put into an unrecoverable state if you lose power or communications for any reason IMPORTANT If you are connecting to the SLC 5 05 processor through a hub you can use a standard Ethernet patch cable If you are connecting directly to the SLC 5 05 processor from your computer you need to use an Ethernet crossover cable SLC 500 CAT SER SERI
11. ontrolFLASH Upgrade Publication 1747 IN019F EN P August 2008 16 Highlight the IP address of the PC Ethernet interface that connects to the Ethernet network hosting the target processor 17 Click OK 18 You may need to wait several seconds before the Progress dialog box appears A typical sequence is shown below While the download is in progress the ENET LED changes from a solid green to flashing green to solid red and then turns solid green again When the daughtercard update is complete the ENET LED is flashing green The download process of the daughtercard firmware can take up to approximately two minutes SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade 13 Publication 1747 IN019F EN P August 2008 19 When the message Waiting while module burns flash and all progress bars are displayed check the AB_SNMP dialog box open it from your taskbar if it does not appear automatically The AB_SNMP dialog box prompts you to turn off power remove the processor move the jumper to Program re insert the processor and apply power 20 Wait for the ENET LED to turn solid green 21 Click OK ATTENTION Do not remove the processor from the SLC 500 chassis until all power is removed from the SLC 500 power supply 14 SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade Publication 1747 IN019F EN P August 2008 22 If your PC has more than one Ethernet interface ins
12. rror messages you can receive Invalid Catalog Number Target Module Not in Proper State for Programming Failed to Receive Initial TFTP Request from Target Invalid Catalog Number The following error message is displayed if the ControlFLASH tool is unable to match the processor to the catalog number that was selected in the catalog Number dialog box or the tool is unable to identify the processor type selected because the J4 jumper is in the Program position ATTENTION Do not remove the processor from the SLC 500 chassis until all power is removed from the SLC 500 power supply 20 SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade Publication 1747 IN019F EN P August 2008 To clear this error 1 Click OK 2 Click Cancel to go to the Catalog Number dialog box You may either select the correct catalog number in the dialog box and proceed with the update or power down the processor and check the J4 jumper position 3 Restart the firmware upgrade procedure in the Use ControlFLASH section ATTENTION Do not remove the processor from the SLC 500 chassis until all power is removed from the SLC 500 power supply SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade 21 Publication 1747 IN019F EN P August 2008 Target Module Not in Proper State for Programming The following dialog box appears when this error occurs To clear this error 1
13. t which may lead to personal injury or death property damage or economic loss IMPORTANT Identifies information that is critical for successful application and understanding of the product ATTENTION Identifies information about practices or circumstances that can lead to personal injury or death property damage or economic loss Attentions help you identify a hazard avoid a hazard recognize the consequence SHOCK HAZARD Labels may be located on or inside the equipment e g drive or motor to alert people that dangerous voltage may be present BURN HAZARD Labels may be located on or inside the equipment e g drive or motor to alert people that surfaces may be dangerous temperatures SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade 3 Publication 1747 IN019F EN P August 2008 For More Information Related Publications To view and download pdfs go to Literature Library at http www rockwellautomation com literature To order printed copies contact your Allen Bradley Distributor or Rockwell Automation Sales Office System Requirements Personal computer with at least a 486 processor Windows NT 2000 or XP operating system At least 32 MB of memory or the minimum required by the operating system Ethernet connection to SLC processor Install ControlFLASH Insert the CD ROM of the ControlFLASH Firmware Upgrade Kit into your CD ROM drive The Setup W
14. talled then the following dialog box displays the assigned IP addresses of each of the listed Ethernet interfaces Otherwise go to step 24 23 Highlight the IP address of the PC Ethernet interface that connects to the Ethernet network hosting the target processor Click OK 24 The AB_SNMP BOOTP Server Running dialog box may appear SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade 15 Publication 1747 IN019F EN P August 2008 A Progress dialog box is displayed again A typical sequence is shown starting below While the download is in progress the RUN and FLT LED indicators remain off The other four LED indicators RS232 ENET FORCE and BATT turn on and off in a walking bit sequence When the update is complete these four LED indicators remain on together The download process of the firmware takes approximately 3 minutes 16 SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade Publication 1747 IN019F EN P August 2008 25 Open the AB_SNMP dialog box from the task bar if it does not appear automatically Follow the dialog box prompts to do the following i Verify the LEDs have stopped flashing ii Turn off power to the chassis iii Remove the processor iv Set the motherboard jumper J4 back to Protect v Re insert the processor vi Apply power to the chassis 26 Once you have re applied power wait for the ENET LED indicator to turn solid green Click OK
15. trolFLASH section or if the processor has been reset to Initial Factory Conditions use an available IP address assigned by your network administrator SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade 9 Publication 1747 IN019F EN P August 2008 11 Enter the hardware address of the SLC 5 05 processor that is being upgraded noted in step 2 of the Prior to Running ControlFLASH section and click OK The AB_SNMP BOOTP Server Running dialog box may take several seconds or minutes to appear 10 SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade Publication 1747 IN019F EN P August 2008 You may need to wait several seconds or minutes before you are returned to the AB_SNMP DLL Enter IP Address dialog box Within a few seconds the Device Identification box displays the processor s current revision information 12 Click OK 13 Select the appropriate revision from the Firmware Revision dialog box and click Next SLC 5 05 Processors Firmware Operating System ControlFLASH Upgrade 11 Publication 1747 IN019F EN P August 2008 The Summary dialog box appears 14 Click Finish The ControlFLASH dialog box appears 15 Click Yes If your PC has more than one Ethernet interface installed the following dialog box displays the assigned IP addresses of each of the listed Ethernet interfaces Otherwise go to step 18 12 SLC 5 05 Processors Firmware Operating System C

Download Pdf Manuals

image

Related Search

Related Contents

macLEDS SNAP-flat-LO-19.5-W-24WAC Installation Guide  Vendredi 28 août 2015  verifique o papel - Mega Suprimentos  Vitoria-Gasteiz(e)n, En Vitoria  全ページダウンロード(7.39MB)  Apple Loops Utility User Manual (for SoundTrack Pro)  ITI CareTaker EZ Owner`s Manual  4 Instalação  Renesas Starter Kit for RSKM32C87 User`s Manual  Maverick Ventures ET-85 User's Manual  