image

Contents

1. Electric bracket Pressing board Pressing board 1 Connection cables X Connect the grounded wire correctly otherwise will cause the malfunction of some electrical componet and shock or fire indeed X Don t reverse the power polarity X Must fix the screwnail of the firmly wire then drag the wire lightly confirmation whether it s firmly X If there is a connector connect it directly The connection of connection cables of indoor unit and outdoor unit must _ correspond from the graph in down otherwise itcould be cause shock or fire Indoor Unit L N 8 L N 8 Outdoor Unit Blue Zero line Yellow Green Grounded wire C i Brown Live wire NOTE This manual is usually includes all the wiring mode for the different kind A C please refer to the corresponding guide and instruction when wiring We cannot exclude the possibility that the product should be improved and caused the change of wiring please refer to the wiring diagram adhered on the A C purchased 17 Testrunniny e Makesure that pipes and wires are connected e Make sure that liquid side valve and air side valve both are completely open 1 The connection of power source e Connect the wire to independent power source socket e Preparation ofremote controller e Run the air conditioner in cooling operation mode for 30 minutes o
2. 6 Usetwo 7 batteries do not use the electric batteries 7 Take the batteries out of remote controller before stop its using for long 8 When the noise of transmitting signal can t be heard indoor unit orthe transmission symbol on the display screen doesnt flare batteries need be replaced 9 lf reset phenomenon occurs on pressing the button of the remote controller the electric quantity is deficient and new batteries need to be substituted 10 The waste battery should be disposed properly 26 Notes 27 MUNDE CLIMA ASK FOR MORE INFORMATION Phone 34 93 446 27 80 Fax 34 93 456 90 32 eMail mundoclima salvadorescoda com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 Fax 34 93 635 45 08
3. The unit comes preloaded for liquid pipe lengths less than 5 m For greater lengths see table below Pipe lenght Additional charge R410A Models 9k y 12k Model 18k More than 5m R410A Lenght 5 x 20g m R410A Lenght 5 x 30g m The maximum total pipe length is 15 m The maximum vertical length is 5 m The diameters of the pipes are MUPR 09 H5 MUPR 12 H5 MUPR 18 H5 6 35 1 4 9 52 3 8 6 35 1 4 12 7 1 2 6 35 1 4 15 6 5 8 11 e Firstmake changes to wall and make sure thatis hard and secure Using four type screws to fasten the installation board onto the wall Keep it water lever horizontal direction and perpendicular in vertical direction Otherwise it might cause water drops when air conditioner is running cooling operation e Pull outthe indoor unit pipes after No _ detached the fixed parts on them POD Connectthe interconnected pipes to bine 5mm 7 the indoor unit point to the center of connectio eens Connection ipe Nut pipe pipe and fasten the connection screw Y at first by hand and then by wrench until you hear the Click sound PE Spame 4 i Fastening direction is shown in the ae right picture Using torque is shown Drilling 7Omm diameter in the following table pipe hole atthe left down or right down side of the installation board The Remove the base L hole shall slant outward supp
4. water or something into air conditioner e Unusual noise can be heard during operation e Electrical wiring and power plug are very hot O Wind blowing from the outlet smells terrible during operation e The Run light or other display flashes rapidly and keeps flashing after repluging 9 X Guide for customer 1 Please read the instructions carefully before installation of the air conditioner 2 The installation should be carried out by specialists 3 Installation the air conditioner and connecting the pipe and wires must be strict to reference the instructions 4 The wiring must be done by qualified electrician according to the electrical safety requirements 5 The customer should have a qualified power supply which coincides with the tag of air conditioner the normal voltage should be in the range of 90 110 of its rated voltage 6 The air conditioner must be well grounded the switch of the main power of air conditioner must be reliably grounded Notices 1 The air conditioner must be installed on well strong supporter 2 The appliance shall be installed in accordance with national wiring regulations 3 Fix the machine firmly otherwise it will produce abnormal noise and vibration 4 Install the outdoor unitin the place where it wouldn t disturb your neighbour 5 The method of connection of the appliance to the electrical supply and inter connection ofseparate somponents please see the electric connection elements sh
5. MUNDk 4CLIMA INVERTER SERIE H5 Installation and User s manual MUPR H5 CL20736 to CL20738 This unit must be installed by a professional according CE 795 2010 Sea nglis CONTENTS Safety Precautions 1 WEEE Warning 4 Name Of Each Part 5 Operation 6 Notices 7 Care and Maintenance 8 Troubleshooting 8 Installation Guide 10 Selection of the installing position 11 Installation of the indoor unit 12 Installation ofthe outdoor unit 13 Pipe connection 14 Electrical connection 16 Test running 18 Packing list 18 Remote controller 19 IMPORTANT Thank you for selectiong super quality Air Conditiones To ensure satisfactory operation for many ears to come this manual should be read carefully before the installation and before using the air conditioner After reading store it a safe place Please refer to the manual for questions on use or in the event that any irregularities occur This Air Conditioner should be used for hosehold use This unit must be installed by a professional according CE 795 2010 WARNING The power supply must be SINGLE PHASE one phase L and one neutral N with his grounded power GND and his manual switch Any breach of these specifications involve a breach of the warranty conditions provided by the manufacturer NOTE In line with the company s policy of continual product improvement the aesthetic and dimensional characteristics technical data and accessories of this appliance may be changed wi
6. OFF AUTO FAN A SET ROOM RUNNING COOL HIGH we e d MODE DRY MID RUNNING ee HEAT LOW 4 ere lt em SPEED lt q TIMER ON OFF ON OFF 2 9 SET 4 ic FEELING ON OFF display 10 rl aan a when the remote controller is ii S W y the on state the LCD will be SLEEP FRESH STRONG displays otherwise will not be 12 CO H HA4 display SWING DUST FEELING Digital display UO eet A Under the state of normal 4d FUNGUSPROOF SCREEN gt working It displays set a temperature while the feeling Mo function is start It will displays 15 8 room temperature and under the state of timer mode It will displays settimer y a ee 1 ON OFF button You can start the air conditioner by pressing this button and stop its operation by pressing it again 2 FRESH button This button is invalidation 3 SPEED button You can select fan speed show as the follow Lows Mid F_ High F Auto 4 STRONG button Only under the state of cooling or heating mode press this button the fan speed is adjusted to strong auto maticlly and the LCD displays high fan the strong functionis started to reach the highest cooling or heating 20 Remote Controller 5 FEELING button When it displays FEELING button Press this button can be used to set the feeling function The LCD shows the actual room temperature when the function set and it shows the setting temperature when
7. and to prevent the evaporatorfrom going mouldy due to water deposition and thus dispersing strange smell Note 1 This function has not been setin the factory You may freely set and cancel this function The setting method is under off status of the A C and the remote controller point the remote controller toward the A C and continuously press FUNGUSPROOF pushbutton for one time the buzzer keep beeps five times again after five times beeps indicating that this functionis ready In case this function has been set unless the whole A C is powered off or the function is manually cancelled the A C then has this function as a default 2 To cancel the function 1 Power off the whole A C 2 Under off status of the A C and the remote controller point the remote controller toward the A C and continuously press FUNGUSPROOF pushbutton for one time the buzzer keep beeps three times again after five times beeps indicating that this functionhas been cancelled 3 When this function is on it is suggested not to restart the A C before it is completely stop 4 This function will not run in case of time stop or sleep stop 23 Remote Controller Usage Fix batteries 1 Slide open the cover according the direction indicated by arrowhead 2 Put into two brand new batteries 7 position the batteries to right electric poles amp 3 Put back the cover Automatic operation mode 1 Press the MODE butt
8. art which stick on the machine 6 If the power supply cord is damaged it must be replaced by the manufacture or its service agent ora similar qualified person 7 After installation the power plug should be easily reached 10 selection ofthe installing position Indoor Unit e There is no heating and steaming source nearby e No obstacles for installing position nearly e Keep good air circulation e Convenient to adopt P Abovel5 measures to reduce noises e Do not install them near the ha ta NNS doorway e Make sure to have the distance between the ceiling wall furniture and other A obstacles E e 2 meters high above the floor w K Outdoor Unit A NA e In case that you put up acanopy to protect Y it from rains and sunrays pay attention not d to cause any obstacles for the heating dispersion for the condenser i e Do not grow animals or plants near the ES installation location for the cold and hot air LJ out will affect them LJ Make sure to have the distance specified w in the picture between ceiling wall furniture and other obstacles e Stay away from heating source and z PARA CUNAS A H inflammable air e The installation base and supporting frame should be strong and secure The machine should be at plane surface 8 TINTI 4 RE II LT
9. e off Bolt Vertical airflow Pol two covers from the front frame and then direction plate unfasten two fixture screws Front frame e Pull the front frame towards yourself and take it off In case that put the front frame back turnthe perpendicular airflow direction handle from E ES a to horizontal then proceed according to and dake ofthe TOn frame the third and the second steps You should check whether the front frame is firmly inside the fixture groove onthe top 2 Check the water discharge e Puta cup of water into groove Check whether the water flow through the water discharge hole e The outdoor unit must be firmly fixed to avoid falling in the strong wind e Install on the cement base the drawing below e Ifit will be installed at seaside or ata place high above the ground and with strong wind the AC should be installed against the wall to ensure the normal operation of the fan and the blocking plate should be used e Ifit will be installed in type the structure of the mounting surface should be made of solid stick cement or materials with equivalent strength and be of enough bearing capacity Otherwise measures such as reinforcement support or vibration damping should be adopted Installation outdoor unit bolt Outdoor Unit Size of Right installation feet z Air outlet Outdoor Unit 13 e Connect the pipe to the unit point to the center of pipe and fasten by wrench until it is tightly
10. eled dustbin Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact you local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and SS well being When replacing old appliances with new ones the retailer is legally obligated to take back your old appliance for disposals at least free of charge A Indoor Unit Air inlet 4 2 Indoor Unit aa 3 1 Front panel la N n 2 Airfilter y A 3 Handling switch SS 4 Pe 5 K 4 Louver Air outlet e 5 Signal receptor e 6 6 Supply cord gt kee 7 Remote controller y Y L 8 Drain hose 9 Refrigerant gas X Outdoor Unit Y liquid pipe 9 N Air inlet yp lt h Outdoor Unit 10 Cut off valve 11 11 Air outlet cover Air outlet Note 1 Ifthe power supply from outdoor unit you can find the power supply card is fitted in the outdoor unit 2 The descriptions in this user manual are
11. erature can be set at 1C difference range from 16 32 C 3 Press the SPEED button you can select fan speed You can select fan speed from LOW MID HIGH AUTO 4 Press the ON OFF button the operation indicator is on the air conditioner starts to operate the automatic mode Press the button again the air conditioner stops Night Luminous Function of Remote Controller Only the remote controller with this function can be used For your convenient use of the remote controller in the darkness without any lighting this remote controller has blue background light and luminous pushbuttons Function at you press on any of the pushbutton the background light will immediately release soft light so that you are easy to operate the remote controller If you do not operate the controller within 10 seconds the background light will automatically disappear Note Allthe figures above are the displays after being initially electrified or re electrified after power off In actual operations the remote controller screen displays related items only 25 Remote Controller Attention 1 Aim the remote controller towards the receiver on the air conditioner 2 The remote controller should be within 8 meters away from the receiver 3 No obstacles between the remote controller and receiver 4 Do not drop or throw the remote controller 5 Do not putthe remote controller underthe forceful sunrays or heating facilities and other heating sources
12. fastened the fastening direction is in the following picture A Referthe direction to the picture The form of pipe Use sealing tape to cover the small leaks on the external ring of the pipe Wrap up with tape AON Pipes or Water discharge pipe Connection wire Control panel cover et rm Ls j D an F CUY AER PSUR if i Nl i Connection wire Round in this shape to prevent water entering the electrical parts e Wrapup all pipe water discharge and connection wire from top to below e Coverthe connection and fix them with two plastic rings e Wrapupthe pipes with tape alongside the wall and fix them to the wall with clips These steps are usually adopted when outdoor unitis installed below the indoor unit 14 15 88mm 2 e Pointing towards the center of pipe fasten the screw with strength e Wrench the screw in the end until you hear the Click sound gt Indoorunit Connection screw Pipe Wrench Torque ho s wrench Ou tdo Oseas Torque wrench Round shape Use sealing tape to cover the small leaks on the external ring of e In case that you want to have additional water discharge pipe the end of pipe should be within certain distance towards to surface don t let it under the water Fix it onto the wall so it won t be swayed by the wind e Wrap the pipes and connection wire well from below to top e Wrap
13. fire 7 Children should be supervised to ensure that they do not play with the appliance oy 8 Don t share the socket with other electric appliance and use the broken or unstandord cord Otherwise it ww can cause electric shock even fire 9 Clean the dust on the plug regularly Otherwise the dust mixed humidity will result in insulation fault even A fire 10 An earth leakage breaker with rated capacity must be installed to avoid possible electric shocks 11 Cut off the main power switch when notusing the unit for a long time Otherwise it may cause product failure or fire 12 Stop operation and cut off the main power in storm or hurricane Operation with windows opened may cause electric shock E 13 Don t install air conditioner in a place where there is flammable gas or liquid The distance between them should above 1m It may cause fire 14 Don t put a finger a rod or other object into the air outlet or inlet As a fan is rotating at a high speed it will cause injury 15 Don t touch the swinging wind vanes It may clamp your finger and damage the driving parts of the wind vanes E 16 Don t attempt to repair the air conditioner by yourself ss You may be hurt or cause further malfunctions O 17 Take care not let the remote control and the indoor unit a watered or being too wet or may short circuit even p ES caused fire AY 18 Don t use liquid or corrosive cleaning agen
14. gain to set the timer off function 8 SCREEN button You can letthe LCD displays working or not by pressing this button Q O 21 Remote Controller 9 A or VW button Pressthe or button you can setthe temperature range from 16 C to 32C Display will change as you touch the button 10 CLEAN button a When remote controller is at the off state press clean button the wind guiding bars turn to initial postions for cooling the A C runs clean function with max duration 35mins The purpose of its function is to clean duston evaporator and dry the inside water ofevaporator and to prevent the evaporator going moldy due to water deposition and boasting strange smell b After setting clean function press clean button againto cancel clean functionor press ON OFF button tocancel clean function and start A C c The clean function will be no working after 35 minutes running working without any operation Note clean function can be set in parallel with time start function in this case time start function will be executed after clean function 11 MODE button Which enables you to select different operation mode after each pressing the operation mode will be changed It shows in the following display AUTO COOL DRY HEAT FAN AUTO Remark cold wind type has no heating function 12 SLEEP button 1 press
15. it could cause deformation or depigment e Don t use thinner polishing powder benzene and other volatile chemicals O Don t use liquid or corrosive detergent clean the appliance and don t splash water or other liquid onto it otherwise it may damage the plastic components even cause electric shock x Cleaning air filter Front panel Front panel Aa WE Es SS Aictiter ka 1 Raise up the front panel of indoor unit until it suddenly stop then raise up the protruded part of air filter and then take it out 2 Use a vacuum cleaner or wash them with water then dry it in the shade 3 Reinsert the air filter into the indoor unit until being entirely fixed then close the front panel Ak Maintenance 1 Select FAN operation mode 2 Turn off the air conditioner and cut make the air conditioner run a off the powersupply ER E long time to dry Os A 9 P 3 Take out the batteries from the remote 4 Clean air filters and other parts controller O Troubleshooting Check the following before requesting on service centre if the malfunction occurs Trouble shooting Has the power been shut down Is the wiring loose Air conditioner dose Is the voltage higher than 1 1 times of max rated voltage not operate atall or lower than 0 9 times of min rated voltage Is the fuse burnt Does it reach the set time for start up O s the remote controller out of effective distance to the indoor unit Remote contr
16. low pressure valve on the gas pipe side 2 Connect the charge hose connection to the vacuum pump 3 Fully open the handle Lo of the manifold valve 4 Operate the vacuum pump to evacuate After starting evacuation slightly loose the flare mut of the Lo valve on the gas pipe side and check thatthe air is entering Operation noise of the vacuum pump changes and a compound meter indicates O instead of minus SA Cover Refrigerant 5 After the evacuation is complete fully Outdoor el close the handle Lo of the manifold valve al A Gasside DE and stop the operation of the vacuum Liquid side b pump Make evacuation for 15 minutes or more and check that compound meter Packed valve Half union indicates 76cmHg 1 x 10 Pa lis 6 turnthe stem ofthe packed valve B about Compound meter Pressure gauge 45 counterclockwise for 6 7 seconds Tecmtig C O afterthe gas coming out then tighten the flare nutagain Make suer the pressure display in the pressure indicator isa little higher than the atmosphere pressure 7 Remove the charge hose from the Low pressure charge hose 8 Fully open the packed valve stems B andA 9 Securely tighten thecapofthe packed valve Low pressure valve 15 Wa Handle Hi Charge hose Vacuum pump EN No TITTTTTT11 11 1 Power wiring and interconnection mus
17. oller is not available O s the battery exhausted O Are there any obstructions between the controller and the signal receptor O s the setting temperature suitable e Is the air inlet or outlet obstructed e Are air filter dirty e Is indoor fan speed set at low speed O s there any heat source in your room Cooling Heating efficiency is not good Indoor unit does not operate Once the air conditioner is stopped immediately when the air it will not operate in approximately conditioner is restarted 3 minutes to protect itself l This is caused by the odour inthe There is unusual smell blowing from Do the outlet after operation is started room permeated from building material furniture orsmoke Sound of water flow can be heard This is caused by the refrigerant during cooling operation flowing inside the unit eae l Because the air of the room is cooled Mistis emitted during cooling operation down rapidly by the cold wind and it looks like the fog Mistis emitted during heating This generate dueto moisture in operation defrosting process O Alow hissing sound is caused by Low noise can be heard during Meme cien rowing operation O Alow squeak sound is caused by the deformation of plastic due to temperature In case the following situation please immediately stop all operations and cutoff the power supply then contact with service centre O The fuse and switch often breaks O Carelessly splash
18. on select the automatic operation mode 2 Press the SPEED button you can select fan speed You can select fan speed from LOW MID HIGH AUTO 3 Press the ON OFF button the operation indicator is on the air conditioner starts to operate the automatic mode Press the button again the air conditioner stops Cooling Heating operation mode cold wind type has no heating function 1 Press the MODE button select the Cooling or Heating Operation mode 2 Pressthe A or V button set the temperature temperature can be setat 1 C difference range from 16 32 C 3 Press the SPEED button you can select fan speed You can select fan speed from LOW MID HIGH AUTO 4 Press the ON OFF button the operation indicator is on the air conditioner starts to operate the automatic mode Press the button again the air conditioner stops 24 Remote Controller Fan operation mode 1 Pressthe MODE button selectthe Cooling or Heating operation mode 2 Pressthe SPEED button you can select fan speed You can selectfan speed from LOW MID HIGH 3 Pressthe ON OFF button the operation indicator ison the air conditioner starts to operate the automatic mode Press the button again the air conditioner stops Remark Inthe circulation operation mode to set the temperature is noneffective Drying operation mode 1 Press the MODE button selectthe Dry operation mode 2 Pressthe A or V button set the temperature temp
19. on can be used temporarily in case you can not use remote controller or its batteries are exhausted e When the air conditioner stops the horizontal wind vane will close the wind outlet of air conditioner Notices To prevent injury and property damage Please pay attention to these following before operating the air conditioner Checking before operation 1 Make sure thatthe earth wire is connected safely and reliably 2 Make sure the filter net is properly fixed 3 Make sure that air outlet and inlet are not blocked 4 Please clean the filter before starting the air conditioner referring to page to 6 Cleaning for how to operate 5 Check to see whether the outdoor install bracket is damage If yes please contact our Service center locally Safety tips In order to use the air conditioner properly please refer to its working temperature range Otherwise indoor unit automatic protection function may be activated cooling or heating efficiency will be weakened The air conditioner may can t run in normal followed under mentioned table Outdoor PATO Cooling Indoor lt 18 C Outdoor lt 12 C Heating Indoor 730 C Ak Cleaning sx Cleaning the indoor unit 1 Turn offthe air conditioner and remove the electrical plug from the outlet 2 Wipe the indoor unit with dry cloth or wet cloth which is dipped by cold water Note e Don t use water above 45 C to wash the panel or
20. ort foam in one side SO f A slightly before installation LEK Wall Base Connection pipe Wall air conditioner C Plastic strap Note The installed air conditioner won t be tightly appressed to the 28 Cab wall if that is not arranged shown in A able thepicture The outflow tube must be in the bottom and the highest a Cable lt M point of it can not exceed the Outflow tube position of water basin Connection E Outflow tube pipe R e Arrange the connection pipes cable outflow tube according to the figure then connect the drain pipe to the draining hole e Use insulation sleeve to warp the position of connection pipe and indoor unit then wrap the insulating tape on the sleeve to avoid condensate water e Fasten connection pipes cables and drain pipe together by plastic strap e Hang the indoor unit to the board and make sure the machine is in the middle of the board Connection wire Pushing the machine towards the left down and right down side of the installation board until the hangers enters tightly the grooves fz it makes click sound Water discharge pipe 12 A Check the water discharge 1 Take off the frame the unitcover Take offthe front frame for maintenance according to the following steps e Turnperpendicular airflow direction handle from to horizontal direction e As shownin the picture onthe right tak
21. plug and plug in to restart the air conditioner after several seconds 9 It is forbidden to let the air conditioner keep precision instrumentation artistic production for long time and make food fresh otherwise abnormal using will cause damage and weaken 10 It is forbidden to let children and the disabled use air condition without other adult checking 11 Open windows frequently after using air condition for a long time 12 If your air conditioner is not fitted with a supply cord and a plug an all pole switch must be installed in the fixed wiring and the distance between contacts should be no less than 3 0 mm 13 If your air conditioner is permanently connected to the fixed wiring and have a leakage current that may exceed 10 mA Leakage protector must be installed in the fixed wiring 14 The power supply circuit should have leakage protector and air switch of which the capacity should be more than 1 5 times of the maximum current 15 If the equipement emissions cannot meet the technical requirement of IEC 61000 3 3 Following Attention should be take care Attention Through poor conditions of the electrical MAINS shortly voltage drops can appear when starting the EQUIPMENT This can influence other equipment eg Blinking of a lamp If the MAINS IMPEDANCE Zmax lt OHM See below form such disturbances are not expected In case of need you may contact your local supply authority for further information Meaning of crossed out whe
22. r longer 2 Performance evaluation Discharged air e Test the out and in air temperature e Make sure whether the outlet air temperature subtract from inlet s gives more than 10C e Please check the following attach carefully if part attach isn t useful please take care of it Packing list of the indoor unit Quantity Remote controller Instructions POE PC C Certificate Outdoor unit Pipeprotectionring Po Certificate Quantity 18 Remote Controller AIR CONDITIONER REMOTE CONTROLLER INSTRUCTIONS gt a 3 SET TEMPERATURE C AUTO FAN COOL HIGH DRY MID HEAT LOW ZN O ON OFF SET o S MODE CLEAN SPEED MEA U SLEEP FRESH STRONG fT SS Me AS No EA SWING DUST FEELING ue Qoo p HEALTH FUNGUSPROOF SCREEN TIMER Cajal e A eReadthis instructions carefully so that you can use the air conditioner safely and correctly e Take good care ofthe instructions so that it can be referred to at any time 19 Remote Controller Buttons description E le D LCD displays instruction N SET TEMPERATURE C TRANSMIT DIGITAL ON
23. t meet model 09K 12K 18K 24K Specification of a cables 2x25 T 2x25 T 2x44T 2x4 T The power supply 230V 50Hz is connected only to the indoor unit Xx Indoor connection Open the front panel insetthe connection cablesfromthe base ofthe air conditioner conneting tothe terminal board in order accordingto the graph using the pressing board to fasten the connection cables Pressing board Connection cables Open the front panel ifthe indoor unit is fitted with the signal wire please detach the mid frame and insertthe signal wire through the bottom frame then connect the signal wire quick plug of the indoor s to the outdoor s YY Outdoor connection e Unscrewthe screw take off the control panel coverfromthe unit e According the connect position of indoor unit make sure the connection cables connet to the board of outdoor unit corresponding e The grounded wire connection 1 loosen the grounded screw of electric bracket 2 Connect the grounded wire with the grounded screw then setscrew in the mark formerly Fix the cable to the terminal board with pressing board e Reinstall the cover with the screw 16 D o E E te c L 5 o e o gt t Electric bracket
24. t wipe the air conditioner and sprinkle water or other liquid either cd Otherwise the inclosure will be damaged even electric 6 shock 19 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety CAUTION 1 Don t install the indoor unit under sunshine directly 2 Don t block air inlet or air outlet otherwise the cooling or heating capacity will be weakened even cause system stop operating 3 Don t apply the cold air to the body for a long time It will deteriorate your physical conditions and cause health problems 4 Close the windows and doors otherwise the cooling or heating capacity will be weakened 5 If the air filter is very dirty the cooling or heating capacity will be weakened Please clean the air filter regularly 6 lt was prohibited to stand or put things onto the top of the outdoor to avoid drop or damage In no case should children be allowed to sit on the outdoor unit 7 Set the suitable temperature especially there are old people children and patients in the room Generally keep the temperature difference for 5C between the inside and outside 8 In case that the unit occurs closing down due to the severe interference from outer environments such as mobile phone please cut off the
25. text and figures may have slightly difference to the promotion information and actual appliance Please refer to the real appliance purchased Thank you Remote controller operation See air conditioner remote controllerinstruction Manual operation 5 Manual operation When the remote controller does not work or can not be found please follow these steps 1 As the unit is operating you can press the Auto button RITA to stop operating Em 7 2 As the unit is stopping you can press the Auto button T to start operating Z N sx Adjusting air flow direction 1 Adjusting horizontal air flow manually Use your hands to move the vertical airflow vane and change the horizontal wind direction N Note a Adjust the horizontal air flow direction before the air conditioner starts Don t insert your finger into air intake or outlet vents when the air conditioner is operating b For appliance with auto pendulum wind function please refer to air conditioner remote controller instruction for how to adjust horizontal air flow 2 Adjusting vertical air flow direction up down Refer to air conditioner remote controller instruction for how to adjust vertical airflow direction through adjusting the horizontal airflow vane by remote controller ANote e Adjust the vertical air flow direction by remote controller When you adjust the horizontal airflow vane by hand the machine may cause problem e Manual operati
26. the function cancelled This function is invalid when the appliance atthe Fan mode 6 DUST button This button is invalidation 7 TIMER button Setting the ON timer time a When remote controller is at off state press TIMER button the LCD displays TIMER ON and the timer time the range of setting time is 0 5h to 24h b You can press the A or y button to adjustthe timer time each touch will be set time to increase or reduce 0 5h before 10 hours ago after ten hours will be set time to increase or reduce 1h per pressing to enables your required timer Press TIMER button again to set the timer on function You can set another function to insure the suitable state after air conditioner turn on including mode temperature swing fan speed and etc The LCD will displays all your setting and keep it when the timer reach to the set time the air conditioner will be working according to your set automatically Setting the OFF timer time a When remote controlleris aton state press TIMER button the LCD displays TIMER OFF and the timer time the range of setting time is 0 5h to 24h b You can press the A or V button to adjust the timer time each touch will be set time to increase or reduce 0 5h before 10 hours ago after ten hours will be set time to increase or reduce 1h per pressing to enables your required timer c Press TIMER button a
27. the SLEEP button the sleeping indicator light of indoor unit flashes on 2 after the setting of sleeping mode the cooling operation enables the set temperature to increase 1 C after 1hour and another 1 C automatically after 1 hour 3 after the setting of sleeping mode the heating operation enables the set temperature to drop 2C after 1hour and another 2 C automatically after 1 hour 4 the air conditioner runs in sleeping mode for 7 hours and stops automatically Remark press the MODE or ON OFF button the remote controller clears sleeping mode away 22 Remote Controller 13 SWING button Press this button the horizontal wind direction vanes can rotate automatically when you have the desired vertical wind direction press it again the horizontal wind direction vanes will be stopped at the situation of your choice 14 HEALTH button Press this button you can turn on or off the health function 15 FUNGUSPROOF button ThisA C has special dry and anti mold function which has yes or no two selections This function is controlled by the remote controller under cooling dry and auto cooling and dry modes the horizontal wind guiding bars are atthe initial position for cooling The A C runs under heating mode the cooling only A C only runs under fan mode the internal fan runs for three minutes with weak wind before stop The purpose of this function is to dry the inside ofthe evaporator
28. thout notice Safety Precautions Incorrect operation due to ignoring instruction will cause harm or damage The seriousness is classified by the following indications WARNING This symbol indicates the possibility of death or serious injury CAUTION This symbol indicates the possibility of injury or damage to properties only WARNING 1 This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision 2 this appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial use by lay persons 3 The air conditioner must be grounded Incomplete grounding may result in electric shocks Do not connect the earth wire to the gas pipeline water pipeline lightning rod or telephone earth wire 4 Don t pull out the power plug during operating or with wet hands It can cause electric shock or fire 5 Don t pull the power cord when pull out the power plug The damage of pulling power cord will cause serious electric shock 6 The power plug must be inserted tightly Otherwise it can cause electric shock or overheating Los even
29. upthe pipes that are rounded up by the wall comers in the way shown inthe picture so itcan prevent water entering the room e Useclips or other fixture to fasten the pipes tothe walls X Expelling the air in the pipes and the indoor unit Expelling the air humid air inthe refrigerating system might cause trouble ir id air i Outdoor unit of compressor Take off the cover from the stop valve and T branch valve Take off the auxiliary cover from the T branch valve Turn the stop valve rod anti clock wise to an angle of 90 degree keep it open for 8 seconds andclose the valve AD o A a Check whether there is airleakage at yaporside Gas side all connection parts of pipes Push the top rod of T branch valve by N ZZ Stop valve open hexagon wrench to expel air a Repeat the third and fifth steps Open the stop and T branch valve with 7 a hexagon wrench to make the unit gt operate BX ta vd p There is no leakage allowed please check all the piping connection parts 3 T branch valve open You musttestthe leakage generally auxiliary cover Hexag nwrench itcan be tested by soap water Ifthe A C is filled with R410a make sure to discharge air and moisture remaining inthe refrigerant system with a vacuum pump For method of using a manifold valve refer to its operation manual 1 completely tighten the flare nuts A B C D connect the manifold valve charge hose to acharge port of the