1. MITSUBISHI ELECTRIC GOT2000 Series Wireless LAN Communication Unit User s Manual GT25 WLAN Thank you for purchasing the GOT2000 Series Prior to use please read both this manual and detailed manual thoroughly to fully understand the product MODEL GT25 WLAN U JE MODEL CODE IB NA 0800522 A 1311 MEE 1D7MM2 GRAPHIC OPERATION TERMINAL GoT_o000 SAFETY PRECAUTIONS Always read these precautions before using this equipment Before using this product please read this manual and the relevant manuals intro duced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as WARNING and CAUTION I Indicates that incorrect handling may cause hazardous I A WARNING conditions resulting in death or severe injury l l Indicates that incorrect handling may cause hazardous l l A CAUTION conditions resulting in medium or slight personal injury or physical damage l Note that the A CAUTION level may lead to a serious accident according to the circumstances Always follow the precautions of both levels because they are important to per sonal safety Please save this manual to make it accessible when required and always forward it to the end user INSTALLATION PRECAUTIONS AWARNING Be sure to shut off all phases of
2. Tel 27 11 928 2000 Hong Kong Mitsubishi Electric Automation Hong Kong Ltd 10th Floor Manulife Tower 169 Electric Road North Point Hong Kong Tel 852 2887 8870 China Mitsubishi Electric Automation China Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Tel 86 21 6120 0808 Taiwan Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd Rd Wu Ku Hsiang Taipei Hsine Taiwan Tel 886 2 2299 2499 Korea Mitsubishi Electric Automation Korea Co Ltd 1480 6 Gayang dong Gangseo ku Seoul 157 200 Korea Tel 82 2 3660 9552 Singapore Mitsubishi Electric Asia Pte Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2460 Thailand Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Moo 4 Serithai Rd T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2 517 1326 Indonesia P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 India Messung Systems Pvt Ltd Electronic Sadan NO III Unit No15 M 1 D C Bhosari Pune 411026 India Tel 91 20 2712 3130 Australia Mitsubishi Electric Australia Pty Ltd 348 Victoria Road Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAP
3. the external power supply used by the system before mounting or removing this unit to from the GOT Not doing so can cause a unit failure or malfunction INSTALLATION PRECAUTIONS CAUTION Use this unit in the environment that satisfies the general specifications described in the GOT2000 Series User s Manual Hardware Not doing so can cause an electric shock fire malfunction or product damage or deterioration Do not drop the unit or subject it to string shock A unit damage may result When installing this unit to the GOT fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range Undertightening can cause a drop failure or malfunction Overtightening can cause a drop failure or malfunction due to screw or unit damage STARTUP AND MAINTENANCE PRECAUTIONS Before starting cleaning always shut off GOT power externally in all phases Not doing so can cause a unit failure or malfunction Undertightening can cause the GOT to drop short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit Do not disassemble or modify any unit This will cause failure malfunction injuries or fire Do not touch the conductive areas and electronic parts of this unit directly Doing so can cause a unit malfunction or failure CAUTION Always make sure to touch the grounded metal to discharge the electricity ch
4. AN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permission Specifications subject to change without notice Printed in Japan November 2013
5. arged in the body etc before touching the unit Failure to do so may cause a failure or malfunctions of the unit DISPOSAL PRECAUTIONS A CAUTION Dispose of this product as industrial waste TRANSPORTATION PRECAUTIONS A CAUTION Make sure to transport the GOT main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the User s Manual for the GOT used as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation When fumigants that contain halogen materials such as fluorine chlorine bromine and iodine are used for disinfecting and protecting wooden packaging from insects they cause malfunction when entering our products Please take necessary precautions to ensure that remaining materials from fumigant do not enter our products or treat packaging with methods other than fumigation heat method Additionally disinfect and protect wood from insects before packing products Before Using the Product Precautions for Use Do not modify this wireless LAN communication unit in any way Doing so is prohibited by the Radio Act Japan Data transfer in wireless LAN communication may not be as stable as that in cable communication A packet loss may occur depending on the surrounding environment and the installation location Be s
6. e 64bit 128bit WEP Security 4 WPA PSK TKIP AES WPA2 PSK TKIP AES Number of antennae 1 Build in chip antenna Internal current consumption 3 3VDC 04A Weight 0 05kg 1 The wireless LAN communication unit only functions as a station Commercially available wireless LAN access points are required separately 2 IEEE802 11n only supports 2 4 GHz bandwidth 3 The values of data rates 11Mbps and others used in this document and the setting screen are the theoretical maximum of the wireless LAN standard These values do not indicate the effective data rates 4 When security authentication is performed by WEP or TKIP method the wireless LAN communication unit cannot communicate by IEEE802 11n To communicate by IEEE 802 11n perform the security authentication by WPA PSK AES or WPA2 PSK AES method 3 PART NAMES AND EXTERNAL DIMENSIONS Unit mm inch Description 1 Mounting screw Screw for fixing the GOT 2 Rating plate 3 Locating lug Locating lug fit into the locating groove of the GOT Extension connector connected to the side interface 4 Extension connector of the GOT 4 INSTALLATION AND REMOVAL PROCEDURE 4 1 Unit Installation The installation procedure for the wireless LAN communication unit is explained using the GT2712 1 Turn off the GOT 2 Remove the side interface cover of the GOT 3 Fit the locati
7. lear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system U E Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 Brazil MELCO TEC Rep Com e Assessoria Tecnica Ltda Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Germany Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen GERMANY Tel 49 2102 486 0 U K Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB U K Tel 44 1707 276100 Italy Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni Pal Perseo Ingr 2 Via Paracelso 12 l 20041 Agrate Brianza Milano Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France Tel 33 1 5568 5568 South Africa Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa
8. ng lug of the wireless LAN communication unit into the locating groove of the GOT and install the wireless LAN communication unit to the extension connector 4 Tighten the mounting screws 2 places of the wireless LAN communication unit with a No 1 Phillips screwdriver and a torque of 0 10Nem to 0 14Nem to fix the unit 5 Install the side interface cover to the GOT 4 2 Unit Removal For removing the wireless LAN communication unit reverse the procedure of the installation 5 PRECAUTIONS To use the wireless LAN communication unit installing the system application and setting the controller are required For the settings and system configuration refer to the following n GOT2000 Series Connection Manual Microcomputer MODBUS Products Peripherals For GT Works3 Version Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuc
9. rity settings of the wireless LAN equipment according to the manual before using the wireless LAN communication unit and wireless LAN access point Please be aware that the security settings do not provide complete security protection due to wireless LAN specifications If you are unable to configure the security settings yourself please contact your local authorized dealer The customer is responsible for configuring the security settings and understanding the risks inherent in using the product without the security settings configured Manuals The following shows manuals relevant to this product Detailed Manual Manual number Manual name Model code GOT2000 Series User s Manual Hardware SH 081194ENG Sold separately 1D7MJ5 GOT2000 Series User s Manual Utility SH 081195ENG Sold separately 1D7MJ6 GOT2000 Series Connection Manual Microcomputer MODBUS Products SH 081200ENG Peripherals For GT Works3 Version 1 1D7MkK2 Sold separately For detailed manuals refer to the PDF manuals stored in the DVD ROM or CD ROM for the drawing software used Relevant Manuals For relevant manuals refer to the Help or the PDF manuals stored in the DVD ROM or CD ROM for the drawing software used 2013 MITSUBISHI ELECTRIC CORPORATION Packing List After unpacking the box check that the following products are included 1 OVERVIEW This user s manual describe
10. s the GOT2000 Series wireless LAN communication unit hereinafter referred to as the wireless LAN communication unit The wireless LAN communication unit is used to perform the operations such as transferring data from a personal computer to the GOT or FA transparent function in wireless LAN communication Commercially available wireless LAN access point eL GT25 WLAN GOT Personal computer For the usable GOTs refer to the following GOT2000 Series User s Manual Hardware For the setting and system configuration of wireless LAN function refer to the following I GT Designer3 GOT2000 Help GOT2000 Series User s Manual Utility GOT2000 Series Connection Manual Microcomputer MODBUS Products Peripherals For GT Works3 Version1 For the wireless LAN access point use the access point compatible with IEEE802 11b g n 2 SPECIFICATIONS The following shows the performance specifications of the wireless LAN communication unit The general specifications of the wireless LAN communication unit are the same as those of the GOT For the general specifications of the GOT refer to the following GOT2000 Series User s Manual Hardware Item Specifications Standard 2 IEEE802 11b g n compatible Channel 11ch 1 to 11ch IEEE802 11b up to 11Mbps Data rates 3 IEEE802 11g up to 54Mbps Wireless LAN IEEE802 11n up to 72 2Mbps communication A Wireless connection specifications 1 Infrastructure mode mod
11. ure to perform a confirmation of operation before using this product This product is available for use only in Japan Security Precautions Wireless LAN uses radio waves instead of LAN cables to send and receive data between a computer and a wireless LAN access point making it possible to freely establish a LAN connection within a range of the radio waves However radio waves can be received through obstacles such as walls when within the range Therefore if security settings are not made the following problems may occur Unauthorized viewing of data An unauthorized third party can intercept the radio waves and sneak a look at user ID and password Unauthorized access An unauthorized third party can access network and cause the following damage Intercepting personal information and confidential information information leak Using a false identity to communicate and disclose information illegally identity theft Changing and transmitting intercepted data tampering Damaging data and systems by spreading a computer virus destruction The wireless LAN communication unit and wireless LAN access point have security features to counter these problems Configuring the security settings before using the wireless LAN equipment can help to prevent these problems from occurring The security settings of the wireless LAN equipment are not configured at the time of purchase To reduce security problems configure all secu