Home
User manual - SG Armaturen
Contents
1. User manual Luminaires with Micas HF motion detector CE X Technical data for Micas HF motion detector Area of use Indoor mounted in ceiling or on wall Operating voltage 230V 50Hz Class P degree 5 8 GHz 75MHz lt SmW ca 1 0W Frequency range Radiated power Stand by power Detection 360 120 detection angle Can detect through glass and wood Mounting height Recomended height for wall mounting 2 0m Ceiling mounting max 4 0m See user manual of luminaire See user manual of luminaire Sensor luminaire Sensor Slave luminaire Slave S Sensor luminaire Slave Sensor luminaire Slave The luminaires are equipped with 2 5mm 1 8mm pushwire terminals with integral cable release rated for maximum 16A The cables must not exert any bending forces onto the terminal block contacts during connection wA 40 60 Detection The sensor detects motion moving persons within the detection field Ifa motion is detected the light is switched on for a defined hold time Motion is detected better when moving towards the luminaire Cautions Switch off the power supply before any installation or maintenance operations Mounting The luminaire must not be exposed to vibrations The sensor luminaire will be damaged if connected to a dimmer The luminaire must be secured with a 10A fuse Setup The sensor has three buttons to set up the fol
2. d for one minute Hold time Step1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 10 seconds 60 seconds 2 minutes 5 minutes 10 minutes 15 minutes 30 minutes Each time movement is registered the hold time is restarted When setting the sensitivity or during function testing using shortest possible hold time is recommended Reset Press the Sensitivity and Hold time keys simultaneously for 5 seconds to reset to the factory settings Connecting several luminaires Additional luminaires slaves can be connected to the sensor luminaire The electronics in the sensor luminaire will then control the slaves Max load for one sensor is 500W See the connection diagram above SG Armaturen AS P O Box 105 N 4792 Lillesand Norway Phone 47 37 26 84 84 Fax 47 37 26 84 94 E mail firmapost sg as no
3. lowing functions Sensitivity Daylight sensor Hold time If a button is pressed the corresponding function is switched to the next step Version 24 4 2013 The current step is acknowledged by flashing an LED 1 5 times depending on current step After reaching the highest step it starts again with step 1 Sensitivity setup Step1 20 Step2 30 Step 3 50 Step 4 75 factory setup Step 5 100 The maximum detection range 100 is up to 10m in case of wall mounting Daylight sensor Step1 Daylight the lamp works always ever during daylight Factory setup The lamp works only in case of a threshold value lower than approx 300 lux The lamp works only in case of a threshold value lower than approx 150 lux Twilight the lamp works only in twilight and darkness below approx 50 lux Darkness the lamp works only in darkness below approx 5 lux The lux values are measured at the sensor inside the luminaire Actual values depend on the shape and transparency of the shade Step 2 Step 3 Step4 Step 5 The teach mode is a special setup for the daylight sensor The teach mode is entered by pressing the daylight button longer than 3 seconds The sensor then makes a calibration and works in the current brightness and below This is acknowledged by a flashing LED After two minutes time to close the luminaire the daylight is measure
Download Pdf Manuals
Related Search
Related Contents
COSMOquick User Manual 取扱説明書・お料理ノート Samsung LW30A23W Bruksanvisning Baixar manual Samsung HT-TZ212 Uživatelská přiručka Asus PRL-DL User guide IP-Telefon 55i – Installationsanleitung Stand-alone cumulative elapsed Copyright © All rights reserved.
Failed to retrieve file