Home
CTC series of dry-block - Cameron Instruments Inc.
Contents
1. c cccecees Any value within range Miscellaneous Serial data interface cccccceeeeeeeeees RS232 9 pin Male Operating temperature 008 O to 40 C 32 to 104 F Storage temperature 00000 20 to 50 C 4 to 122 F PUUIETIIOUIY sosen Ne O to 90 RH Protection GIASS antasendrssdocticnoesvosaspeecettetessasbsacbsndeneavesns IP 10 DNV Marine Approval Certificate no c008 A 10384 J J m 1 P P PHYSICAL SPECIFICATIONS Instrument dimensions CTC 140 A CTC 320 A CTC 650 A LXWXH naiiai 241 x 139 x 325 mm 9 5 x 5 5 x 12 8 in CTC 320 B CTC 650 B CTC 1200 A LXWXH aiaia 241 x 139 x 408 mm 9 5 x 5 5 x 16 1 in Instrument weight CTC 140 A CTC 320 Buu ecceccccceeseeeeeeeeeeeneees 7 kg 15 5 Ib OTGOG 320 A errin arai aa ERER Ernani 5 kg 11 Ib GG B50 Fy ccaseicussicintncerecetassanteciendeevctnanoceutnaenteneteude 6 kg 13 Ib GG 6 50 B oncoran a aaiae 10 5 kg 23 Ib CTG I200 A sinirep neotena annei 12 kg 26 5 Ib Insert dimensions CTC 140 A outer diameter cceee 19 1 mm 0 75 in CTC 140 A inner diameter cccceeee 15 0 mm 0 59 in CTC 140 A lenght ccceeceeeeeeseeeeseneeeeees 100 mm 3 9 in CTC 320 CTC 650 A outer diameter 25 7 mm 1 01 in CTC 320 CTC 650 A inner diameter 21 5 mm 0 85 in CTC 320 CTC 650 A lenght 0008 120 mm 4 7 in CTC 320 CTC 650 B outer diameter 25 7 mm 1 01 in CTC 32
2. temperature JOFRA calibration NK Temperature ranges CTC 140 A 17 to 140 C 1 to 284 F CTC 320 A 33 to 320 C 91 to 608 F CTC 320 B 33 to 320 C 91 to 608 F CTC 650 A 33 to 650 C 91 to 1202 F CTC 650 B 33 to 650 C 91 to 1202 F CTC 1200 A 300 to 1205 C 572 to 2200 F Fast calibration is timesaving The specially designed heating block profile heats up to 320 C 608 F in just 4 minutes and to 650 C 1202 F in only 10 minutes High flexibility You are not limited by fixed holes Inter changeable insertion tubes are used to match the diameter of your sensor under test Enhanced stability MVI circuitry ensures stability despite mains supply variations in the process environment Timesaving features Fast one key one function access to the automatic switch test and auto stepping Documentation made easy RS232 communication and JOFRACAL calibration software are included in the standard delivery Complete marine program Part of a complete program of marine approved temperature pressure and signal calibrators including temperature sensors ISO 9001 Manufacturer Specification Sheet SS CTC Compact Temperature Calibrator CTC series 0 at OF i s P Y OZE DLOD A fast timesaving and reliable true temperature calibrator designed for on site use The CTC series is a fast dry block that offers both interchangeable inserts the MVI stability circu
3. CTC 140 A cccceeeee 150 VA Power consumption max CTC 320 B ccccseee 600 VA Power consumption max CTC 1200 A 0006 650 VA Power consumption max CTC 320 A 650 A B 1150 VA Temperature range CTC 140 A Maxin neei ES 140 C 284 F Minimum ambient temp 0 C 32 F 30 C 22 F Minimum ambient temp 23 C 78 F 17 C 1 F Minimum ambient temp 40 C 104 F 2 C 28 F CTC 320 A B cccccseeccssseeeeeeeees 33 to 320 C 91 to 608 F GTG 650 AY B seviccescicidnssiadebvesasias 33 to 650 C 91 to 1202 F CTC 1200 A 1 ccc eeccceeeeee sees 300 to 1205 C 572 to 2200 F Resolution user selectable Selectable ccccccsseeccesseeceeeeceeeeesaeeessaeeeeeas 1 or 0 1 C F Stability CTC 140 A 00 cc ceccecceeeeecesseeeceseeeessereseeereeeset0 05 C 0 09 F CTC 320 AY Be dacitcinnrietiet cern emnbaduatetaweeesst 0 1 C 0 18 F CTC 650 A 1200 Pia cirsacctsiecsnpierniteancaeieceans 0 1 C 0 18 F DLO EE E E A ETE 0 05 C 0 09 F Measured after the stability indicator has been on for 10 minutes Measuring time is 30 minutes Time to stability approximate GI GH1AO A saanane a NE ERRE RNa 5 minutes CTC 320 650 A B cccccscscscececececcececccscscesavananeees 8 minutes GIGHIZOO A soren anA ANEREN NAUNET 20 minutes Accuracy OTC l40 A onnan NENNE AKN 0 4 C 0 7 F CTC 320 A B nerssisinsninnnsinenairnnndinannrnsis
4. 230 A B C D E F G H XXX Description Base model number CTC 140 A 17 to 140 C 1 to 284 F CTC 320 A 33 to 320 C 91 to 608 F CTC 650 A 33 to 650 C 91 to 1202 F CTC 320 B 33 to 320 C 91 to 608 F CTC 650 B 33 to 650 C 91 to 1202 F CTC 1200 A 300 to 1205 C 572 to 2200 F Power supply US deliveries 60 Hz only 115VAC 230VAC Mains power cable type European 230 V USA CANADA 115 V UK 240 V South Africa 220 V Italy 220 V Australia 240 V Denmark 230 V Switzerland 220 V Israel 230 V Insert type and size 1 x Insert for dry block configuration please see the previous insert pages for the right insert codes Calibration certificate NLP Traceable temperature certificate standard for Europe Asia Australia and Africa NIST traceable temperature certificate standard for Western Hemisphere Accredited certificate with 5 std points except CTC 1200 A Accredited certificate with 4 std points for CTC 1200 A X CTC650A230AM01FX Options Carrying case No option used Sample order number CTC 650 A dry block 230 VAC power with European power cord and insert Pre drilled multi hole type 1 1 x 3 mm 1x4mm 1x5mm 1x6mm 1x9mm and NLP traceable certificate AMETEK TEST amp CALIBRATION INSTRUMENTS AMETEK Denmark A S Gydevang 32 34 3450 Aller d Denmark T 45 4816 8000 ametek ametek dk Information in this document is subject to cha
5. aasanannsannsnninnnnnnnnenrnnnnnnnnnnnnannnanannnnnnn 10 kg 22 Ib ZO A esrdsnnodianirinonsindaninnninn nannaa 8 kg 17 5 Ib CTC 650 A aasasinnssnninsnnrnnnninenrinnnnnnannnnannnanannnanan 9 5 kg 21 Ib Size L x W x H 465 x 255 x 470 mm 18 3 x 10 0 x 18 5 in OTC 320 B ereere R A ERa 11 kg 24 Ib Oa Oi oo 0k B eee ee ne eee ne ee 14 kg 26 Ib OOF asi a adi 15 kg 32 Ib Size L x W x H 465 x 255 x 470 mm 18 3 x 10 0 x 18 5 in Shipping carrying case only WVCIOMN sosaren a EE 5 0 kg 11 Ib Size L x W x H 507 x 232 x 415 mm 19 9 x 9 1 x 16 3 in JOFRA calibration INSERTS FOR CTC SERIES Inserts for CTC 140 A and CTC 320 A B are made of aluminum Inserts for CTC 650 A B are made of brass Inserts for CTC 1200 A are made of high temperature steel alloy All specifications on hole sizes are referring to the outer diameter of the sensor under test The correct clearance size is applied in all predrilled inserts Undrilled inserts CTC 140 A Inserts undrilled CTC 140 A CTC 320 A CTC 650 A CTC 320 B CTC 650 B CTC 1200 A p Pace upenled 60F448 100175 100194 60F356 60F420 124403 Undrilled aulation plug 123987 see below Spare part no for predrilled inserts metric mm Undrilled inserts CTC 320 650 A B Probe diameter Insert code CTC 140A CTC 320A CTC 650 A CTC 320 B CTC 650B CTC 1200 A 123428 124503 124406 124504 124407 007 124505 008 124506 Und
6. 0 CTC 650 B inner diameter 21 5 mm 0 85 in CTC 320 CTC 650 B lenght 00 200 mm 7 9 in CTC 1200 A outer diameter cccceceese eens 25 mm 0 98 in CTC 1200 A inner diameter c ccceeseeeeees 22 mm 1 6 in CTC 1200 A lenght cccccecessseeeneeeeeeees 155 mm 6 1 in Weight of non drilled insert approximate CTC 140 Fc ccsstan ccoustuctasmcusecdatpwtiinnsisecnaiehestecjacss 75 g 2 6 oz OTG 320 A reene ea E a eE REENE 170 g 5 8 oz OCTG 650 A ernennen aa Ea riani 510 g 17 8 oz C TG 320 B ectociwssixtrecresctanncamecueduenictocinpcsckoanntesss 280 g 9 8 oz C TO 5950 B enirere aa aE 860 g 30 3 oz CTC 1200 een 460 g 16 3 oz Use of other inserts may reduce performance of the cali brator To get the best results out of the calibrator the insert dimensions tolerance and material is critical We highly advise using JOFRA inserts as they guarantee trouble free operation Shipping including optional carrying case CTC 140 A ee enn 12 5 kg 27 6 Ib CTC 320 A csc cepetetntiesiertedeentncessactustenesveneee 11 kg 24 Ib CTC 650 A ceccccccssecescseseesetsessecsesensetstssesetseeeeee 12 kg 27 Ib CTC 320 B vcoesmesvevizesnesensiveeseneesnensevecestinestin 13 5 kg 21 Ib GO 5120 B nerina oiia 17 kg 37 Ib CTC 1200 A vo reavscerorarincticciedesstvatnecyaceucrctateoett 18 kg 39 Ib Size L x W x H 507 x 232 x 415 mm 19 9 x 9 1 x 16 3 in Shipping without carrying case CTC 140 A
7. Cleaning Brushes 4 mm Package of 3 pcs Cleaning Brushes 6 mm Package of 3 pcs Cleaning Brushes 8 mm Package of 3 pcs Insulation in Tube 100 mm x 25 mm Insulation in Tube 150 mm x 25 mm Insulation in Tube 200 mm x 25 mm Insulation in Tube 250 mm x 25 mm Insulation in Tube 300 mm x 25 mm Insulation in Tube 350 mm x 25 mm Insulation in Tube 400 mm x 25 mm Insulation in Tube 450 mm x 25 mm Set of Insulation Plates 10 pcs Extra fixture for sensor grib Extra sensor grib Edgeport Converter with 4 pcs of RS232 ports Carrying Case CTC MTC A models Carrying Case CTC B models and for CTC 1200 A Insulation Plugs for CTC 1200 124414 124415 124416 124518 124519 Insulation plug 8 pcs 12 mm in Insulation plug 8 pcs 3 4 mm and 1 8 in Insulation plug 8 pcs 5 6 mm and 1 4 3 16in Insulation plug 3 pcs 7 8 9 mm and 5 16 in Insulation plug 8 pcs 10 11 mm and 3 8 7 16 in DDN oN Carrying case Optional The optional protective carrying case ensures safe trans portation and storage of the instrument and all associated equipment FUNCTIONAL SPECIFICATIONS Mains specifications Voltage CTC 140 320 650 1200 5 115V 90 127 230V 180 254 Voltage CTC 650 B 115V 105 127 230V 210 254 Frequency non US deliveries 50 Hz 5 60 Hz 5 Frequency US deliveries ccccseseeeeeeeeeeeeeees 60 Hz 5 Power consumption max
8. c ture together and to electrically insulate the individual elements from one another Maximum temperature From the setup menu the user can select the maximum temperature limit for the calibrator This function prevents damage to the sensor under test caused by the applica tion of excessive temperatures The feature also aids in reducing drift resulting from extended periods of expo sures to high temperatures This feature can be locked with an access code MVI Improved temperature stability MVI stands for Mains power Variance Immunity Unstable mains power supplies are a major contributor to on site calibration inaccuracies Traditional temperature calibrators often become unstable in production environ ments where large electrical motors heating elements and other devices are periodically cycled on or off The cycling of supply power can cause the temperature regu lator to perform inconsistently leading to both inaccurate readings and unstable temperatures MV NORMAL MAINS The CTC series employ the MVI thus avoiding such stabil ity problems The MVI circuitry continuously monitors the supply voltage and ensures a constant energy flow to the heating elements Easy to use intuitive operation All instrument controls may be performed from the front panel The heat source is positioned away from the panel This design helps to protect the operator The main functions on the CTC series are designe
9. d with one key one function logic This means that there are no sub menus or difficult to remember multiple keystrokes necessary to access primary functions The easy to read backlit display features dedicated icons which help in identifying instrument conditions and operational steps AMETEK CALIBRATION INSTRUMENTS SWITCH AUTOX ESCH TEST STER MENU Set temperature The Up and Down arrow keys allow the user to set the exact temperature desired with a resolution of 0 1 Instrument setups The CTC series stores the complete instrument setup including engineering units stability criteria resolution display contrast slope ramp rate auto step settings and maximum temperature Stability indicator A bold checkmark on the display indicates that the cali brator has reached the desired set temperature and is stable The operator may change the stability criteria and establish a greater sense of security in the calibration results A convenient countdown timer is activated five minutes before the unit reaches stability Automatic switch test Operators can save a lot of time using the automatic ther moswitch test function to find values for the Open and Close temperatures Additionally this feature displays the hysteresis deadband between the two points The feature ensures a very high repeatability when testing thermoswitches Simply press the SWITCH TEST key t
10. dependent source is necessary Of course AMETEK can provide you with a traceable calibration cer tificate from our labs when you require a higher level of confidence Calibration of up to 24 sensors with JOFRA ASM Using the CTC series together with the ASM Advanced Signal Multi scanner offers a great time saving automatic solution to calibrate multiple temperature sensors at the same time The ASM series is an eight channel scanner controlled by JOFRACAL software on a PC Up to 3 ASM units can be stacked to calibrate up to 24 sensors at the same time It can handle signals from 2 3 and 4 wire RTD s TC s transmitters thermisters temperature switches and volt age JOFRA calibration JOFRACAL CALIBRATION SOFTWARE JOFRACAL calibration software ensures easy calibration of RTD s thermocouples transmitters thermoswithes pressure gauges and pressure switches JOFRACAL can be used with JOFRA DPC 500 HPC and IPI pressure calibrators all JOFRA temperature calibrators as well as AMC900 ASC300 multi signal calibrator and ASM 800 signal multi scanner he JOFRACAL calibration software may also be used for manual calibrations as it can be set up to accept manual entry of calibration data together with other liquid baths ice points or dry block heat sources The calibration data collected may be stored on a PC for later recall or analysis The calibrator stores the calibration procedure and may be ta
11. design heats up the CTC 320 A to maximum temperature in just 4 minutes and the CTC 650 A in only 10 minutes The fast performance of the heating block is due to the special profile that minimizes mass and yet still accepts an insertion tube with a 25 mm 1 in outer diameter This design is a balanced compro mise between temperature stability homogeneity and rapid heating cooling Deep immersion depth The CTC 320 B and CTC 650 B models offer a deeper immersion depth of 200 mm 7 9 in If you have liquid filled sensors or other sensors that require a deeper immersion depth look for the B versions While the units do not heat and cool as quickly as their shorter counterparts they offer the capability to accommodate longer sensors Peltier effect CTC 140 A The model CTC 140 A features Peltier elements In 1834 Jean Peltier a French physicist found that an opposite thermocouple effect could be observed when an electric current was connected to a thermocouple Heat would be absorbed at one of the junctions and discharged at the other junction This effect is called the gt PELTIER EFFECT A A The practical Peltier element electronic heating pump consists of many elements of semiconductor material connected electrically in series and thermally in parallel These thermoelectric elements and their electrical inter connections are mounted between two ceramic plates The plates serve to mechanically hold the overall stru
12. eeeeeeeees 20 minutes CTC 650 B 23 to 650 C 73 to 1202 F ananena 39 minutes CTC 1200 A 23 to 1205 C 73 to 2200 F 7 0 2 ceceeceeececeeecereers 45 minutes Cooling time CTC 140 A 100 to 0 C 212 to 32 F 10 minutes 0 to 15 C7 3210 5 F anomien 16 minutes 140 to 100 C 284 to 212 F uo ccc ese eeceeeeeeeeeeees 2 minutes CTC 320 A 320 to 100 C 608 to 212 F woe eecceceeceeseeeeeeeees 16 minutes CTC 650 A 650 to 100 C 1202 to 212 F aanne 28 minutes CTC 320 B 320 to 100 C 608 to 212 F wo eeeceececeeeeeeeeeeees 22 minutes CTC 650 B 650 to 100 C 1202 to 212 F aeann 65 minutes CTC 1200 A 1205 to 300 C 2200 to 572 F uu eee c cece eeeeeeees 120 minutes Switch input dry contact Test voltage eeceeeeeeeeeeeeeeeeeeeeeeeeneaeeeneeees Maximum 5 VDC Test current oo ccceccccecceseeceseeseeceeeeseusevaeeas Maximum 2 5 mA Support rod set Optional 125068 Support rod for sensors to be mounted on JOFRA dry block cali brators Holds the sensor under test in their position while calibrating Includes 2 sensors grips and 2 fix tures for sensor gribs JOFRA calibration KEY FEATURES Automatic switch test Finds switching temp 0008 Open close hysteresis Slope rate programmable c cccccceee 0 1 to 9 9 C F Auto stepping PrOQrAMMADIE cccceecceeseeeeeeeeeeeeeeeeneeeeeneeeees Up to 9 steps Dwell time on each SteP cceeceeseeeeeseeeee
13. eeees Programmable Enhanced stability Unstable mains protection ccccceeeeeseeeeeees MVI Circuitry Clear stability indication ccccccceseeeeeeeeees Yes in display Multi information display Stability iNGICAtOM cccccesceeeeeeeeeeseeseeees Bold checkmark Countdown timer before stable c ceeeeeees 4 minutes Temperature ccccccseceeeeees SET and READ simultaneously Alphanumeric messages sccccesecesssetessseeeseneeeseneeesens Yes Calibration status iCONS ccccccccsseceeceeeeceeeeeeeeeeeseaeees Yes Training mode heating cooling block disabled Simulation of all FUNCTIONS c cccceecececececececeeeeceaeeecees Yes Simulating heating and cooling Approx 100 per minute Service facilities Adjustment of the unit from the keypad c s000 Yes Self explaining guide in iSplay cccccsssseeesseeeeeeeeeees Yes Other information ccccseeseeeeeees Displays serial number PAE EE AEA software revision level and last calibration date Setup facilities Stability Criteria cccccscceccsssseeeeeeseeeeeenees Extra time before EE E EA AT E E OE stable indication is shown Display resolution ccccceeceeeeeeeeeeeeeeeeeeeennees 0 1 or 1 C F Temperature units cccccececseccceccceeeeceeeeseeeseneesees C or F Slope rate sacascsaviccnenantenseuewceneiducemmmedaeninnes 0 1 to 9 9 minute Maximum temperature
14. i ninnan 0 5 C 0 9 F CTC 650 A ou ccccccececcecececscscscecavavancucececsesees 0 9 C 1 62 F CRG os 08 B pee nena ee E ni 0 6 C 1 08 F CITG 1200 A sescssietsscscsncinicretiasiccrad ascsiwaninS nan ainara ARANNA 2 0 C 3 6 F Specification when using the internal reference Load 4 mm OD reference probe in the center of the insert Thermal protection shield Optional 104216 An external heat shield is avail able and may be placed on top of the calibrator to reduce the hot air stream around the sensor under test This is especially important for testing thermocouples having head mounted transmitters with cold junction compensation JOFRA calibration Immersion depth CTC 140 A insulation included ccseececceseeeeeeeeeeeeeeeees 115 mm 4 5 in CTC 320 A CTC 650 A CTC 1200 A 110 mm 4 3 in CTC 320 B CTC 650 B e ec eec cesses eee 190 mm 7 5 in Well diameter OTO tA e e areeni 19 2 mm 0 76 in CTC 320 CTCO 650 aaasasesnnnenenennnnnnnennnnnnns 26 mm 1 0 in C2 OG tacts Ea 27 mm 1 6 in Heating time CTC 140 A 17 t0 23 C 7 1 tO FOP eck edcacentiecdcdernctecscenwecdoeences 3 minutes 23 to 140 C 73 to 284 F 00 eeceecceceecereeecereers 15 minutes CTC 320 A 23 to 320 C 73 to 608 F wu eee ecc ccc eeceeeeeeeeeeneees 4 minutes CTC 650 A 23 to 650 C 73 tO 1202 F anneanne 10 minutes CTC 320 B 23 to 320 C 73 tO B08 F uu eeceeceeceeeeee
15. itry and calibration software Both speed and portability are superior to liquid baths Dry block calibrators do not require hazardous liquids and provide a wide temperature range Calibrate RTD s thermocouples thermoswitches thermistors and other common temperature sensing devices The CTC series is designed for both on site and maintenance shop use The applications are generally critical process control but can vary based on calibration and testing requirements The user interface is easy and intuitive One key one function gives you quick access to timesaving fea tures such as the switch test or the auto stepping function All models feature a large backlit LCD display panel which is easy to read even in well lit areas Units feature an informative display that provides icons and information regarding the status of the CTC and the calibration in progress The CTC series consists of six different models that differ in temperature ranges and immersion depths All units offer similar features A rugged slim line aluminum outer casing with die cast top and bottom protects the CTC series of dry block calibrators For easy documentation and automatic calibration all units are delivered with RS232 serial communication and JOFRACAL calibration software AMETEK TEST amp CALIBRATION INSTRUMENTS JOFRA calibration Fast heating and cooling The CTC 320 A and the CTC 650 A contain an innovative heating block profile This
16. ken out to the process site with out using a personal computer Once all calibrations are completed the data may be uploaded to the JOFRACAL calibration software for post processing and printing of certificates The calibration data collected may be stored on the personal computer for later recall or analysis The JOFRACAL temperature calibration software may be donwloaded from our web page www jofra com JOFRACAL software Minimum hardware requirements for JOFRACAL calibra tion software e INTEL 486 processor e PENTIUM 800 MHz recommended e 32 MB RAM 64 MB recommended e 80 MB free disk space on hard disk prior to installation e Standard VGA 800 x 600 16 colors compatible screen e 1024 x 786 256 colors recommended e CD ROM drive for installation of the program e 1 free RS232 serial port STANDARD DELIVERY e CTC dry block calibrator user specified e Mains power cable user specified e Traceable certificate temperature performance e Insert user specified e Tool for insertion tubes e User manual e Reference manual English e Test cables 1 x red 1 x black e RS232 cable 9 pin e JOFRACAL calibration software e CTC 140A only Matching insulation plug kit 8 pcs e CTC 1200 A only Matching Insulation plug kit 8 pcs ACCESSORIES 122832 60F 174 122822 65 F 100 65 F101 65 F102 65 F103 65 F 104 65 F105 65 F 106 65 F107 105173 125066 125067 125002 123408 123409
17. nge without notice 2012 by AMETEK Inc www ametek com All rights reserved S ft a ad a i P W Off a AMETEK Test amp Calibration Instruments A business unit of AMETEK Measurement amp Calibration Technologies Division offering the following industry leading brands for test and calibration instrumentation JOFRA Calibration Instruments Temperature Calibrators Portable dry block calibrators precision thermometers and liquid baths Temperature ranges from 90 C 130 F to 1205 C 2200 F Temperature sensors for industrial and marine use Pressure Calibrators Convenient electronic systems ranging from 25 mbar to 1000 bar fully temperature compensated for problem free and accurate field use Signal Instruments Process signal measurement and simulation for easy control loop calibration and measurement tasks M amp G Pressure Testers amp Pumps Pneumatic floating ball or hydraulic piston dead weight testers with accuracies to 0 015 of reading Pressure generators delivering up to 1 000 bar Lloyd Instruments Materials testing machines and software from Lloyd Instruments guarantees expert materials testing solutions The comprehensive program also covers Texture Analysers to perform rapid general food testing and detailed texture analysis on a diverse range of foods and cosmetics Davenport Polymer Test Equipment Allows measurement and characterization of moisture sensitive PET polymers and polyme
18. o activate the function CALIBRATION INSTRUMENTS Slope rate Ramp Auto stepping This feature saves manpower The operator may stay in the control room or another remote location monitor ing the output from the sensor under test while the CTC series calibrator is placed in the process and automatically changes the temperature using a programmed step value and rate Up to 9 different temperature steps may be pro grammed including the hold time for each step Liquid filled sensors and switches The tall B models with an immersion depth of 190 mm 7 5 in are ideal for calibration of liquid filled sensors The specially designed non linear heating elements in the CTC 650 B and the increased block mass provide a very homogeneous temperature throughout the block It is essential for the quality of the calibration test that the full lenght of the sensing part of the sensor is exposed to the same temperature Calibrate analog reading devices or switches with very high repeatability JOFRA calibration Re calibration adjustments The CTC series has a very easy and straightforward pro cedure for re calibration adjustment There is no need for a screwdriver or PC software The only thing you need is a reliable reference thermometer Place the probe in the calibrator and follow the instruc tions on the display Third party labs and calibration facili ties will be able to perform this function if a certificate from an in
19. r density Chatillon Force Measurement The hand held force gauges and motorized testers have earned their reputation for quality reliability and accuracy and they represent the de facto standard for force measurement Newage Testing Instruments Hardness testers durometers optical systems and software for data acquisition and analysis www jofra com AMETEK Mansfield amp Green North America T 1 800 527 9999 cal info ametek com AMETEK Singapore Pte Ltd Singapore T 65 6 484 2388 aspl ametek com sg AMETEK Inc Beijing Rep Office China T 86 10 8526 2111 jofra ametek com cn AMETEK Instruments India Pvt Ltd India T 91 22 2836 4750 ametek ametek dk AMETEK GmbH Germany T 49 2159 9136 510 info mct de ametek de AMETEK Calibration Instruments UK T 44 0 1243 833 302 jofra ametek co uk
20. rilled inserts 124507 CTC 1200 A 124508 124509 124510 N A A m 3 N N N N Multi hole type 1 N CTC 140 A Na 123440 122517 123458 123466 N Multi holetype1 mot j 1234798 123475 1234768 na wa na Spare part no for predrilled inserts imperial inch Probe diameter CTC 140 A CTC 320A CTC 650 A CTC 320 B CTC 650B CTC 1200 A vain 250 60F454 100180 100199 6oFse2 6oF426 124404 si in 312 6oF456 100181 100200 6oFs64 6oF428 124513 12in 500 60F462 100189 100207 6oFszo 6oF4s4 124405 ein 562 60F464 6oF344 6oF4o8 6oFsz2 6oFsse NA sein 625 6oF466 100192 100210 6oFsz4 corsa na sein 3 Na 6oFas2 6oFsie 105184 6oF4s4 NA Multi holetype2 Moz 1234808 123477 123478 na na na Note 1 Use the insert code when ordered as the standard insert together with a new calibrator Note 2 CTC 140 A only Remember to use matching insulation plugs see accessories Note 3 CTC 140 A only All multi hole inserts are delivered with a matching insulation plug Multi hole Note 4 CTC 1200 A only Remember to order matching insulation plugs See accessories CTC 320 A A A A A A A Multi hole type 1 CTC 320 A 650 A Multi hole type 2 CTC 140 A me oo oO N ORDERING INFORMATION Order number CTC140A CTC320A CTC650A CTC320B CTC650B CTC1200A 115
Download Pdf Manuals
Related Search
Related Contents
User manual ITC Heated Cot Anchorage System ficha petrea lisa 5 U-30-6 - 株式会社クボタ 建設機械事業部 取扱説明書 Website: www.moree.de Bedienungsanleitung / Instruction Manual 取扱説明書 2nd Ave. 0023W934 Owner's Manual Toshiba RAV-SM1403DT-A Air Conditioner User Manual TQ8215 Philips 21PT5307 21" real flat stereo TV Copyright © All rights reserved.