1. is displayed SIEMENS Automation amp Drives Console e Support SIMATIC NET User name admin v Password Figure 7 1 Logon dialog 2 In the User Name list box select the Admin entry if you want to change settings of the SCALANCE X 200RNA read and write access If you select the User entry you only have read access to the configuration data of the SCALANCE X 200RNA 3 Enter your password If you have not yet set a password the default passwords as shipped apply Enter admin if you selected admin as the user name or user if you selected user Note For security reasons make sure that you change the original factory set passwords 4 Click the Log On button to start the logon SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 45 Functional description and configuration using Web based Management 7 3 LED simulation of the WBM 7 3 LED simulation of the WBM Display of the operating state Each SCALANCE X 200RNA has several LEDs that provide information on the operating state of the device Depending on its location direct access to the SCALANCE X 200RNA may not always be possible Web Based Management therefore displays simulated LEDs The top quarter of the screen shows a schematic representation of the SCALANCE X 200RNA with the corresponding LEDs The meaning of the LED displays is described in the section Displays Page 29 in these Operating Instructions SIEMENS
2. Pe CPU Status Status Stat Stat A SIMATIC NET Industrial Ethernet ug SCALANCE X204RNA EEC PAO PB OPI O P2 0 192 168 1 1 En X204 RNA EEC System Passwords 5 18M Current Admin Password E Restart amp Defaults New User Password E Save 8 Load HTTP E Version Numbers User Password Confirmation B Passwords New Admin Password Select Set Button Admin Password Confirmation Event Log x200 ent itc E E d 2 Figure 7 9 System Passwords You apply your settings with Set Values SCALANCE X204RNA SCALANCE X204RNA EEC 56 Operating Instructions Functional description and configuration using Web based Management 7 5 The System menu 7 5 7 System Select Set Button Configuring the Select Set button On the SCALANCE X 200RNA the SELECT SET button is used to e Change the display mode e Reset to the factory defaults e Define the fault mask and the LED display You will find a detailed description of the individual functions available with the button in the section Set button Page 27 On this page the functionality of the Select Set button can be restricted or fully disabled This is possible for the following three functionalities e Restore Factory Defaults e Enable Disable Reset e Set Fault Mask SIEMENS Automation amp Drives Console Support e Logout SIMATIC NET E Status Status Status Status SIMATIC NET Industrial Ethernet SCALANCE X204
3. SCALANCE X204RNA EEC SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 101 Accessories and compatible devices 10 1 Accessories SM robust cable 4x19 125 900 um Order number 6XV1843 2R Available for SCALANCE SCALANCE X204RNA EEC MM LC duplex plug 6GK1 901 0ORB10 2AB0 SCALANCE X204RNA EEC SM LC duplex plug 6GK1 901 0SB10 2AB0 SCALANCE X204RNA EEC C PLUG 6GK1900 0AB00 X 200RNA 102 SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions Accessories and compatible devices 10 2 Compatible devices 10 2 Compatible devices Table 10 2 Compatible SCALANCE X devices oversized frames 1532 bytes SCALANCE X W CSM CPs and PRP Product MLFB As of version SCALANCE XB004 1 unmanaged IE Switch for 10 100 Mbps 6GK5004 1BD00 1AB2 ES 01 SCALANCE XB004 1LD unmanaged IE Switch for 10 100 Mbps 6GK5004 1BF00 1AB2 ES 01 SCALANCE XB004 1G unmanaged IE Switch for 10 100 1000 Mbps 6GK5004 1GL00 1AB2 ES 01 SCALANCE XB004 1LDG unmanaged IE Switch for 10 100 1000 Mbps 6GK5004 1GM00 1AB2 ES 01 SCALANCE X005 IE entry level switch unmanaged 6GK5005 0BA00 1AA3 ES 07 SCALANCE XB005 unmanaged IE Switch for 10 100 Mbps 6GK5005 0BA00 1AB2 ES 01 SCALANCE X005 TS IE entry level switch unmanaged 40 75 6GK5005 0BA00 1CA3 ES 07 SCALANCE X
4. 7 7 The Agent menu SNTP Server IP Address Here you enter the IP address of the SNTP server whose frames will be used by a SCALANCE X 200RNA to synchronize the time of day SNTP Server Port Here enter the port over which the SNTP server is available Time Zone Select the time zone for the location of the SCALANCE X 200RNA because the SNTP server always sends UTC time This time is then recalculated and displayed as the local time based on the time zone There is no standard daylight saving time switchover on the SCALANCE X 200RNA Init poll interval Here you can enter the interval at which a SCALANCE X 200RNA repeats the initial poll for the system time if this was not successful the first time Poll interval Once the system time has been adopted the first time from the time server it is updated cyclically with renewed polls to the time server Here you specify how often the updates take place SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 77 Functional description and configuration using Web based Management 7 8 The Switch menu 7 8 The Switch menu 7 8 1 Introduction Introduction In this menu you set the parameters for the switch functionality assign it to layer 2 of the SCALANCE X 200RNA This includes the following functions e General switch settings such as aging e Display of statistical data 7 8 2 Switch Config Switch functionality The Switch Configuration screen appears
5. A change to the IP address the subnet mask or the default gateway becomes active only following a restart of the device As a result as soon as one of these three values has changed a restart is triggered when you press Set Values After changing the IP address to be able to connect to the SCALANCE X 200RNA again the new address will need to be entered in the WEB browser manually SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 67 Functional description and configuration using Web based Management 7 7 The Agent menu SIEMENS Automation amp Drives Console Support Logout SIMATIC NET n Status Status Status Status SIMATIC NET Industrial Ethernet BN SCALANCE X204RNA EEC PAO PB DPI OFP o 192 168 1 1 X204 RNA EEC Agent Configuration 17 System a 20 0 Agent O SNTP 1 Switch a Syslog pep O DCP Read Only Agent IP Configuration IP Address 192 168 1 1 Subnet Mask 265 255 255 0 Default Gateway 0 0 0 0 MAC Address 08 00 06 10 08 31 Sel Values Figure 7 17 Agent Configuration Settings for the SCALANCE X 200RNA 68 Syslog Here you specify whether or not events are sent to a Syslog server DCP If you select this option the device can be accessed and configured via DCP PST Tool and STEP 7 SNTP Enables disables synchronization of the IE switch system time over an SNTP server in the network DCP Read Only If you select this opti
6. Automation amp Drives Console Support Logout Power CPU Status Status Status Status L1 DF O SIMATIC NET SIMATIC NET Industrial Ethernet SCALANCE X204RNA EEC PA O P8 O P1 m P20 192 168 1 1 E x204 RNA EEC SCALANCE X200 Series y System x200 E Agent a Switch Please select one item of the menu on the left Figure 7 2 LED simulation of the SCALANCE X204RNA EEC SCALANCE X204RNA SCALANCE X204RNA EEC 46 Operating Instructions Functional description and configuration using Web based Management 7 3 LED simulation of the WBM SI EMENS Automation amp Drives Power CPU Status Status Status Status SCALANCE X200 Series Figure 7 3 LED simulation of the SCALANCE X204RNA SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 47 Functional description and configuration using Web based Management 7 4 Working with the WBM 7 4 Working with the WBM Navigation bar The upper menu bar of WBM contains the following links e Console This link is not used here e Support When you click this link you open a SIEMENS AG support page SIEMENS Support is however only accessible when your PC has a connection to the Internet e Logout By clicking on this link you log out from the device Updating the display with Refresh Web Based Management pages have a Refresh button at the lower edge of the page Click this button to request up to date information from t
7. Connection 6 3 Connecting the SFP transceiver Note During startup the signaling contract is always active signals error fault 6 3 Connecting the SFP transceiver Connecting the SFP transceiver The SFP modules are supplied with power via the SFF slot of the SCALANCE X204RNA EEC 6 4 Grounding Grounding SCALANCE X204RNA The housing is made of plastic There is no need and no possibility of grounding SCALANCE X204RNA EEC The device is grounded over the DIN rail There is also a grounding bolt on the underside of the housing Connect the grounding bolt of the device to the nearest grounding point using the grounding cable Use minimum conductor size like supply line conductors but not smaller than 1 56mm2 AWG 16 SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 41 Connection 6 4 Grounding 42 SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions Functional description and configuration using Web 7 based Management 7 1 Introduction Introduction To make the best possible use of the technical possibilities of the SCALANCE X 200RNA devices you can adapt the configuration of the device to the concrete situation in which it is used Web Based Management WBM accesses the configuration of the SCALANCE X 200RNA using a Web browser An Ethernet connection to the device is necessary NOTICE To prevent unauthorized access to the SCALANCE X200RNA there is a
8. http support automation siemens com WW view en 8763736 Manual EMC Installation Guideline http support automation siemens com WW view en 28518276 Configuration manual e Working on the product To protect the product from electrostatic discharge personnel must first discharge any electrostatic charge from their body before touching the product Note The product was tested with a device that also complies with the standards listed above When operating the product with a device that does not comply with these standards adherence to the corresponding values cannot be guaranteed Explosion protection directive ATEX 92 The SCALANCE X204RNA device meets the requirements of the EC directive SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions Approvals and marking 8 1 Approvals and marking 94 9 EC ATEX95 Equipment and protective systems intended for use in potentially explosive atmospheres Note When using installing the SCALANCE X204RNA in hazardous area zone 2 make absolutely sure that the associated conditions are adhered to You will find these conditions on the SIMATIC NET Manual Collection e Approval of SIMATIC SIMATIC NET Products for Direct Installation in Ex Zone 2 ATEX code 113 G Ex nA Il T4 KEMA 07 ATEX 0145X The product meets the requirements of the standards e EN 60079 15 electrical apparatus for potentially explosive atmospheres Type of p
9. 7 6 2 PRP configuration PRP configuration The PRP specific parameters are entered in the PRP Config screen SIEMENS Automation amp Drives Console Support e Logout Power CPU Status Status Status Status SIMATIC NET u aF o SIMATIC NET Industrial Ethernet SCALANCE X204RNA EEC PROPS O P1 D P2 0 192 168 1 1 E x204 RNA EEC X 204 PRP Configuration System 3 X200 PRP Mode PRP Mode 1 B PRP Config Fault Mask Duplicate Aging Time 0 60000 ms 400 Agent Q Switch Refresh Set Values Figure 7 13 PRP configuration PRP Mode Shows the protocol being used PRP Mode 1 This value cannot be changed Duplicate Aging Time The duplicate aging time is entered here The permitted values are between the 0 and 60 000 ms The default value is 400 ms This default value comes from the PRP standard SCALANCE X204RNA SCALANCE X204RNA EEC 62 Operating Instructions Functional description and configuration using Web based Management 7 6 The X200 menu 7 6 3 Fault Mask Function of the fault mask With the fault mask you specify the fault error states to be monitored by the SCALANCE X 200RNA and that will trigger the signaling contact Possible fault error states are the absence of the power supply power supply too low or an interrupted connection or an unexpected connection established to a partner device If the signaling contact is triggered this causes the fault LED on the device to light
10. Y Switch E Ports E FoB Y Statistics E Packet Size E Packet Type B Packet Error 3 PRP Ports Refresh Previous Port Next Port Figure 7 33 Packet Error Statistic Graphic With the check box in the Packet Error column you decide the content of the graphic The value in the Packets column in the graphic is only displayed for a certain packet type if the appropriate check box is selected The Percentage column shows the errors of a certain type as a percentage of the total errors for this port When the percentage is calculated error types are included only if their check boxes are selected With the Previous Port and Next Port buttons you can change to the display of the previous or next port SCALANCE X204RNA SCALANCE X204RNA EEC 88 Operating Instructions Functional description and configuration using Web based Management 7 8 The Switch menu 7 8 9 PRP Statistic PRP Statistic The PRP Statistic page shows interesting statistical data for the PRP protocol The following events are distinguished e Received A Frames at PRP A Port Number of valid A frames received at port PRP A e Received B Frames at PRP B Port Number of valid B frames received at port PRP B e Received B Frames at PRP A Port Number of valid B frames received at port PRP A error e Received A Frames at PRP B Port Number of valid A frames received at port PRP B error If you click the Reset Counters button you
11. 105 Accessories and compatible devices 10 2 Compatible devices Version With unmanaged switches the product version of the hardware is specified because the devices do not have any firmware and device functionality is set using the hardware With other devices the firmware version is specified V x x because the device functionality is set in the firmware SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 106 References 1 1 11 1 References Sources of information and other documentation System manual SIMATIC NET Industrial Ethernet Network Manual The system manuals are only available from the CS home page http support automation siemens com WW view en 27069465 SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 107 References 11 1 References SCALANCE X204RNA SCALANCE X204RNA EEC 108 Operating Instructions Dimension drawings 1 2 12 1 Dimension drawings e 45 0 SIEMENS SALANS i PRP A PRP B Pi P2 SELECT SET 100 0 DC 24V FAULT Mi Fo C oP BEE F2 L2 lol 66K5204 0BA00 2KB2 Y Figure 12 1 SCALANCE X204RNA front view SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 109 Dimension drawings 12 1 Dimension drawings e 82 0 Figure 12 2 SCALANCE X204RNA side view SCALANCE X204RNA SCALANCE X204RNA EEC 110 Operating Ins
12. 60950 1 Information Technology Equipment e CSA C22 2 No 60950 1 03 cULus Approval for Industrial Control Equipment Underwriters Laboratories Inc complying with e UL 508 e CSA C22 2 No 142 M1987 SCALANCE X204RNA SCALANCE X204RNA EEC 94 Operating Instructions Approvals and marking 8 1 Approvals and marking Table 8 1 Certifications and approvals Device type cULus FM CE C Tick Kc ATEX95 Zone 2 E1 SCALANCE X204RNA UL 60950 FM 3611 EN 61000 6 4 AS NZS Korea EN 60079 15 1 CL 1 Div 2 EN 61000 6 2 2064 Class Certification EN 60079 0 CSA GP A B C D A 113 G Ex nA II T C22 2 No T KEMA 07 ATEX 60950 1 CL 1 Zone 2 0145X GP IIC T Ta X204RNA EEC UL 508 EN 61000 6 4 AS NZS Korea CSA EN 61000 6 2 2064 Class Certification C22 2 A No 142 M1987 FM ATEX approval For temperature information T or the maximum ambient temperature Ta refer to the type plate Table 8 2 Mechanical stability Device type SCALANCE IEC 60068 2 6 vibration IEC 60068 2 27 shock X204RNA 5 9 Hz 3 5 mm 15 g 6 ms duration 9 500 Hz 1g 6 shocks per axis 1 octave min 20 sweeps X204RNA EEC 5 9 Hz 3 5 mm 15 g 11 ms duration 9 150 Hz 1 g 10 cycles per axis 6 shocks per axis SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 95 Approvals and marking 8 1 Approvals and marking SCALANCE X204RNA SCALANCE X204RNA EEC 96
13. 6GK5307 3BL00 2AA3 V3 7 0 SCALANCE X307 3LD managed PLUS IE switch 6GK5307 3BM00 2AA3 V3 7 0 SCALANCE X308 2 managed PLUS IE switch 6GK5308 2FL00 2AA3 V3 7 0 SCALANCE X308 2LD managed PLUS IE switch 6GK5308 2FM00 2AA3 V3 7 0 SCALANCE X308 2LH managed PLUS IE switch 6GK5308 2FN00 2AA3 V3 7 0 SCALANCE X308 2LH managed PLUS IE switch 6GK5308 2FP00 2AA3 V3 7 0 SCALANCE X310 FE managed PLUS IE switch 6GK5310 OBA00 2AA3 V3 7 0 104 SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions Accessories and compatible devices 10 2 Compatible devices SCALANCE X W CSM CPs and PRP Product MLFB As of version SCALANCE X310 managed PLUS IE switch 6GK5310 0FA00 2AA3 V3 7 0 SCALANCE X320 1FE managed IE switch 6GK5320 1BD00 2AA3 V3 7 0 SCALANCE X320 3LDFE managed IE switch 6GK5320 3BF00 2AA3 V3 7 0 SCALANCE X308 2M managed IE switch 6GK5308 2GG00 2AA2 V3 7 0 SCALANCE X308 2M TS managed IE switch 6GK5308 2GG00 2CA2 V3 7 0 SCALANCE X308 2M POE managed IE switch 6GK5308 2QG00 2AA2 V3 7 0 SCALANCE XR324 12M MANAGED IE SWITCH 24 VDC cable outlet 6GK5324 0GG00 1AR2 V3 7 0 front SCALANCE XR324 12M MANAGED IE SWITCH 24VDC cable outlet 6GK5324 0GG00 1HR2 V3 7 0 at rear SCALANCE XR324 12M MANAGED IE SWITCH 230 VAC cable outlet 6GK5324 0GG00 3AR2 V3 7 0 front SCALANCE XR324 12M MANAGED IE SWITCH 230 VAC c
14. General menu in the section Temporary Internet Files with the Settings button e Below the text Check for newer versions of stored pages the Automatically check box must be selected SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 51 Functional description and configuration using Web based Management 7 5 The System menu Restart System Click this button to restart the SCALANCE X 200RNA You must confirm the restart in a dialog box During a restart the SCALANCE X 200RNA is reinitialized the internal firmware is reloaded and the device runs a self test The learned entries in the address table are deleted You can leave the browser window open while the SCALANCE X 200RNA restarts Restore Factory Defaults and Restart Click this button to restore the factory defaults for the configuration The protected defaults are also reset An automatic restart is triggered Note By resetting all the defaults the IP address is also lost A SCALANCE X 200RNA can then be accessed using the Primary Setup Tool 7 5 4 System Save 8 Load System Save 8 Load via HTTP 52 The WBM allows you to store configuration information in an external file on your client PC or to load such data from an external file from the PC to the SCALANCE X 200RNA You can also download both new firmware as well as a new FPGA configuration from suitable files on your client PC Note Following a firmware update delete the cache o
15. PLUG configuration plug is an exchangeable medium for storage of the configuration and project engineering data If the device is replaced the configuration can be adopted by swapping the C PLUG Cyclic Redundancy Check A checksum used in transmission protocols to detect errors in frames DCP Discovery and basic Configuration Protocol is used to detect nodes without an IP address and to assign a basic configuration to them for example IP address A network node that forwards all frames not addressed to stations in the same LAN subnet SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 113 Glossary DHCP Event Fault mask DHCP Dynamic Host Configuration Protocol like BOOTP a method for automatic assignment of IP addresses However with DHCP addresses can also be assigned while the device is running for Alarms amp Events An event is any occurrence that might be of interest to the client Although events can also be generated due to a condition being met they do not need to be related to conditions Events that are not related to conditions include for example error messages from the communications system Specifies the desired status good status Deviations from this occurring during operation are handled as faults High Speed Redundancy HSR HTTP Method used on SIMATIC NET switches to increase the network availability in a ring topology See also Media redundancy gt High
16. X302 7EEC 24 VDC POWER SUPPLY UNIT 6GK5302 7GD00 1GA3 V3 7 0 CONFORMAL COATING SCALANCE X302 7EEC 24 VDC REDUNDANT POWER SUPPLY 6GK5302 7GD00 2GA3 V3 7 0 UNIT CONFORMAL COATING SCALANCE X302 7EEC 100 240 VAC VDC POWER SUPPLY UNIT 6GK5302 7GD00 3EA3 V3 7 0 SCALANCE X302 7EEC 100 240 VAC VDC RED POWER SUPPLY 6GK5302 7GD00 4EA3 V3 7 0 UNIT SCALANCE X302 7EEC 100 240 VAC VDC POWER SUPPLY UNIT 6GK5302 7GD00 3GA3 V3 7 0 CONFORMAL COATING SCALANCE X302 7EEC 100 240 VAC VDC RED POWER SUPPLY 6GK5302 7GD00 4GA3 V3 7 0 UNIT CONFORMAL COATING SCALANCE X307 2EEC 24 VDC POWER SUPPLY UNIT 6GK5307 2FD00 1EA3 V3 7 0 SCALANCE X307 2EEC 24 VDC REDUNDANT POWER SUPPLY 6GK5307 2FD00 2EA3 V3 7 0 UNIT SCALANCE X307 2EEC 24 VDC POWER SUPPLY UNIT 6GK5307 2FD00 1GA3 V3 7 0 CONFORMAL COATING SCALANCE X307 2EEC 24 VDC REDUNDANT POWER SUPPLY 6GK5307 2FD00 2GA3 V3 7 0 UNIT CONFORMAL COATING SCALANCE X307 2EEC 100 240 VAC DC POWER SUPPLY UNIT 6GK5307 2FD00 3EA3 V3 7 0 SCALANCE X307 2EEC 100 240 VAC VDC POWER SUPPLY UNIT 6GK5307 2FD00 3GA3 V3 7 0 CONFORMAL COATING SCALANCE X307 2EEC 100 240 VAC VDC RED POWER SUPPLY 6GK5307 2FD00 4EA3 V3 7 0 UNIT SCALANCE X307 2EEC 100 240 VAC VDC RED POWER SUPPLY 6GK5307 2FD00 4GA3 V3 7 0 UNIT CONFORMAL COATING SCALANCE X304 2FE managed IE Switch 6GK5304 2BD00 2AA3 V3 7 0 SCALANCE X306 1LDFE managed IE switch 6GK5306 1BF00 2AA3 V3 7 0 SCALANCE X307 3 managed PLUS IE switch
17. be signaled by breaking the contact The signaling contact is connected to a 2 or 3 pin plug in terminal block Usable cable cross section 0 25 to 2 5 mm Table 6 2 Pin assignment Pin number Pin assignment of the SCALANCE X 204RNA Pin assignment of the SCALANCE X 204RNA EEC Pin 1 F1 NO contact NC contact if a fault occurs F1 NC contact NO contact if a fault occurs Pin 2 F2 F2 pole terminal Pin 3 F3 NO contact NC contact if a fault occurs The following errors faults can be signaled by the signaling contact e The loss of a link on a monitored port see section Setting the fault mask Page 27 e The failure of one of the two redundant power supplies X204RNA only e Theloss of the entire power supply e Internal error e Incompatible C PLUG was inserted The connection or disconnection of a communication node on an unmonitored port does not lead to an error message The signaling contact remains activated until the error fault is eliminated or until the current status is applied as the new desired status using the button When the SCALANCE X 200RNA is turned off the signaling contact is always activated signals error fault Note The signaling contact correlates with the red fault LED Exception The absence of the power supply is signaled only by the signaling contact no display by the fault LEDs SCALANCE X204RNA SCALANCE X204RNA EEC 40 Operating Instructions
18. is then indicated by the message system when there is no power on one of the monitored lines line 1 or line 2 or when the voltage is too low less than 14 V With the SCALANCE X 204RNA EEC this screen is not displayed SCALANCE X204RNA SCALANCE X204RNA EEC 64 Operating Instructions Functional description and configuration using Web based Management 7 6 The X200 menu SIEMENS Automation amp Drives e Console Support Logout SIMATIC NET at CPU Status Status Status Status SIMATIC NET Industrial Ethernet PaO P8 MPI P2 192 168 1 1 X204 RNA EEC X200 Fault Mask Link Down H System 383 X200 Enable Link Down Monitoring E PRP Config Pot AL BL 10 20 Ely Fault Mask Link Down El Link Up Agent Switch Figure 7 15 Fault Mask Link Down Monitoring Enable Link Down Monitoring Select the check boxes of the ports whose connection status you want to monitor If link monitoring is activated an error is signaled when there is no valid link at this port because for example the cable is not plugged in or the connected device is turned off An error fault can be signaled in the following ways depending on the configuration of the SCALANCE X 200RNA Signaling contact fault LED SNMP trap entry in the log table and the syslog SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 65 Functional description and configuration using Web based Management 7
19. of conformity Example German EG Konformit tserkl rung SCALANCE X204RNA Example English Declaration of Conformity SCALANCE X204RNA EMC directive electromagnetic compatibility The SCALANCE X 200RNA devices meet the requirements of the EC directive 2004 108 EEC Electromagnetic Compatibility SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 91 Approvals and marking 8 1 Approvals and marking The product is designed for use in the following areas Area of application Industry RF interference level Immunity to interference EN 61000 6 4 2007 EN 61000 6 2 2005 A WARNING Personal injury and damage to property may occur The installation of expansions that are not approved for SIMATIC NET products or their target systems may violate the requirements and regulations for safety and electromagnetic compatibility Only use expansions that are approved for the system e Keep to the installation guidelines The product meets the requirements if you adhere to the installation and safety instructions contained in this documentation and in the following documentation when installing and operating the product e You can always find the latest documentation on the Internet The current descriptions of the currently available products can always be found on the Internet under the specified Internet pages SIMATIC NET Industrial Twisted Pair and Fiber Optic Networks
20. previously written C PLUG If you want to insert a C PLUG that has already been used and has been written to in a SCALANCE X 200RNA with a different configuration the existing C PLUG data must first be deleted Note An IE Switch X 200 normally starts up with the configuration of the C PLUG assuming this was written to by a compatible device type SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 25 Product characteristics 4 6 C PLUG Diagnostics Inserting a C PLUG that does not contain the configuration of a compatible device type inadvertently removing the C PLUG or general malfunctions of the C PLUG are indicated by the diagnostic mechanisms of the SCALANCE X 200RNA LEDs SNMP WBM etc Inserting in the C PLUG slot The C PLUG is not supplied with the SCALANCE X 200RNA It is available as an optional accessory The slot for the C PLUG is located as follows eWith a SCALANCE X204RNA on the front of the device eWith the SCALANCE X204RNA EEC on the top of the device To insert the C PLUG remove the protective cover The C PLUG is inserted in the slot The protective cover must then be closed correctly NOTICE The C PLUG may only be inserted or removed when the power is off Removing the C PLUG It is only necessary to remove the C PLUG if a fault occurs on the SCALANCE X 200RNA The C PLUG can be removed from the slot using flat pliers tweezers or a small screwdriver If
21. up and depending on the configuration of the event table can trigger a trap or an entry in the log table Device related link monitoring of the ports A SCALANCE X 200RNA provides device related link monitoring A link up or link down also affects the message system if the SCALANCE X 200RNA was appropriately configured Setting the fault mask on the device Optionally the fault mask can be set using the SET SEL button on the SCALANCE X 200RNA For more detailed information refer to the section SET button Page 27 SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 63 Functional description and configuration using Web based Management 7 6 The X200 menu Settings in WBM In WBM you can set the monitoring of the power supply SCALANCE X204RNA only and the device related link monitoring The settings are made in three separate masks SIEMENS Automation amp Drives Console Support Logout ne CPU Status Status Status Status SIMATIC NET Industrial Ethernet L2 m SCALANCE X204RNA PA PB GO P1 O P2 B 192 168 1 2 SIMATIC NET X200 Fault Mask Power 3 X200 Enable Power Monitoring E PRP Config a Fault Mask Line 1 Line 2 El Power El Link Down 7 Agent Switch Figure 7 14 SCALANCE X204RNA Fault Mask Power Monitoring Enable Power Monitoring SCALANCE X204RNA only Here you specify which of the two power supplies of the SCALANCE X204RNA line 1 and line 2 is monitored A fault
22. 0 2AA3 V4 4 SIMATIC NET SCALANCE X204 2TS managed IE Switch 6GK5204 2BB10 2CA2 V4 4 SIMATIC NET SCALANCE XF204 2 flat managed IE Switch 6GK5204 2BC00 2AF2 V4 4 SIMATIC NET SCALANCE X204 2LD managed IE Switch 6GK5204 2BC 10 2AA3 V4 4 SIMATIC NET SCALANCE X206 1 managed IE Switch 6GK5206 1BB10 2AA3 V4 4 SIMATIC NET SCALANCE X206 2LD managed IE Switch 6GK5206 1BC00 2AA3 V4 4 SIMATIC NET SCALANCE XF206 1 managed IE Switch 6GK5206 1BC00 2AF2 V4 4 SIMATIC NET SCALANCE X206 2LD managed IE Switch 6GK5206 1BC10 2AA3 V4 4 SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 103 Accessories and compatible devices 10 2 Compatible devices SCALANCE X W CSM CPs and PRP Product MLFB As of version SIMATIC NET SCALANCE XF208 managed IE Switch 6GK5208 0BA00 2AF2 V4 4 SIMATIC NET SCALANCE X208 managed IE Switch 6GK5208 0BA10 2AA3 V4 4 SIMATIC NET SCALANCE X208PRO managed IE Switch 6GK5208 0HA00 2AA6 V4 4 SIMATIC NET SCALANCE X212 managed IE Switch 6GK5212 2BB00 2AA3 V4 4 SIMATIC NET SCALANCE X212 LD managed IE Switch 6GK5212 2BC00 2AA3 V4 4 SIMATIC NET SCALANCE X216 managed IE Switch 6GK5216 OBA00 2AA3 V4 4 SCALANCE X224 managed IE Switch 6GK5224 0BA00 2AA3 V4 4 SCALANCE X302 7EEC 24 VDC 6GK5302 7GD00 1EA3 V3 7 0 SCALANCE X302 7EEC 24 V DC REDUNDANT POWER SUPPLY 6GK5302 7GD00 2EA3 V3 7 0 UNIT SCALANCE
23. 0RNA reacts to system events By enabling the appropriate check boxes you specify which events trigger which reactions on the SCALANCE X 200RNA The following options are available e The SCALANCE X 200RNA triggers an SNMP trap e The SCALANCE X 200RNA writes an entry in the log file e The SCALANCE X 200RNA writes an entry to the Syslog server SIEMENS Automation amp Drives Console Support e Logout SIMATIC NET CPU Status Status Status Status SIMATIC NET Industrial Ethernet SCALANCE X204RNA EEC PA O P8 OPI MP2 0 192 168 1 1 m X204 RNA EEC Agent Event Configuration System 53 X200 Event Trap Log Table Syslog Y Agent Cold Warm Start SNMP Link Change Trap Config Authentication Failure Timeout Config Fault State Change E Event Confi E Time Confi Redundancy Event 3 Switch Refresh Set Values Figure 7 21 Agent Event Configuration with the SCALANCE X204RNA EEC SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 73 Functional description and configuration using Web based Management 7 7 The Agent menu SIEMENS e Console 4 Support Power CPU Status Status Status Status li B l2 B PA PB Pl DP B L E 5 EE Lea a 3 0 DD DD gt is gf is TD imeout Config Event Config Syslog Config Time Config 1 Switch iw m i Automation amp Drives Logout SIMATIC NET SIMATIC NET Industrial Ethernet SCALANCE X204RNA 192 168 1 2 Agent Event Conf
24. 3 SNMP Trap Configuration wx orinal dd naan eee ae 70 7 7 4 Agent Timeout Configuration ccccccceeeececececeeceeeeeeeeceaeaeeeeeeececaaaeceeeeeeesecceeaeeeeeeeeesessnneeeeess 72 7 7 5 Agent Event Configuration ite sect egstnedeasceecdsiecinenstetien eden ccdaedane a coda 73 7 7 6 Agent Syslog Configuration cccccceceeeececceeceeeeeeeeeeeeneaeaeeeeeeesecaaaeaeeeeeeesecaesaeeeeeeeeesenseceeeees 75 7 7 7 Agent Time Configurations etdan ln a A eA dae de a a are 76 7 8 The SWitchiMeNU iris 78 7 8 1 INTFOJUCION Lati da 78 7 8 2 SWITCH COMO La a A dai 78 7 8 3 Port stats ico ica ici lidad ibi aliada 79 7 8 4 Switch Forwarding Database ooocccccccconococococonccnncnnnnononccnnnnnnnnnnnnnnncnnnnnnnnnnnnnnnnnnnnnnnannnnnnnnnncnnnninns 81 7 8 5 the Statistics Meni ienei cele tens ake ames etc el eke cen ead Ae ated 82 7 8 6 Packet Size Stati stiC seca t ees eaten ceive seers aac a cl 82 7 8 7 Packet Type Statistics italia ibi a ada daze 84 7 8 8 Packet Error StatistiG a aa a a dada 86 7 8 9 PRP Statisties iian st ide 89 Approvals and Marking oia ia taa aatan atka Paaa Aa anaa A ATA 91 8 1 Approvals and MmarkiNg ciclista iaa 91 Technical datar A St ta ia ias 97 9 1 Technical Specifications sieten aa e a a a iiiendada 97 Accessories and compatible devices cccccccccccccncccnnccnncconcnonccnnccnnconononononononnnnnnnnnnonnnnnnnnnnncnnnnnns 101 10 1 ACCESSONGES a e oe Re tata nals 101 10 2 Compatib
25. 6 The X200 menu SIEMENS Automation amp Drives e Console e Support Logout SIMATIC NET Power CPU Status Status Status Status uo SIMATIC NET Industrial Ethernet PA O PB OPI OP oO 192 168 1 1 X204 RNA EEC X200 Fault Mask Link Up a E PRP Config Pot AO 80 10 20 EA Fault Mask Link Down B Link Up Agent Switch Figure 7 16 Fault Mask Link Up Monitoring Enable Link Up Monitoring Select the check boxes of the ports whose connection status you want to monitor If link monitoring is activated an error is signaled when there is a valid link at this port because for example the cable should not be plugged in An error fault can be signaled in the following ways depending on the configuration of the SCALANCE X 200RNA Signaling contact fault LED SNMP trap entry in the log table and the syslog SCALANCE X204RNA SCALANCE X204RNA EEC 66 Operating Instructions Functional description and configuration using Web based Management 7 7 The Agent menu 7 7 The Agent menu 7 7 1 Agent Configuration Introduction The Agent Configuration screen appears if you click the Agent folder icon This screen provides options for setting the IP address You can specify whether a SCALANCE X 200RNA obtains the IP address dynamically or you can assign a fixed address IP Address Enter the IP address of the SCALANCE X 200RNA here Subnet Mask Enter the subnet mask of the SCALANCE X 200RNA here Note
26. 8 4 4 1 SCALANCE X204RNA product characteristics ccccccceeceeeeeeeeeeceeeeeeeeseeenaeceeeeeeeseesinaeeneees 18 4 4 2 SCALANCE X204RNA TP interfaces nerea aeaa a a a A a a EA A E A RAAEN aa 19 4 5 SGALANCE X204RNA EEG nito aa aa A aeaa a a a a aa Naaa 21 4 5 1 SCALANCE X204RNA EEC product characteristics oooooooccoccccnnniccccoccccncccccnncononccnncnnnnnanrncnncnnn 21 4 5 2 SCALANCE X204RNA EEC TP interfaces ooooooccinocccinococionccononcnonoccnnncnnnn nn cnn cnn nnc narrar rra 22 4 5 3 SCALANCE X204RNA EEC SFP interface oocooocinncccinococconccoonnncnnoccnnnnnnnnnnnnnn cnn 23 4 6 C PEUG fix te eet a ies A o E e A e e ld e E 25 4 7 SET DUO Sid A A A AAA eee es 27 4 8 DISplV Soi e 29 4 8 1 Fault indicator yellow red LED Joeriii reniir E canon cnc canon R E nana 29 4 8 2 Power Aspira iaa 29 4 8 3 Port sstatus indication diia 30 4 8 4 LED displaye duning Startup aa a a a 30 5 Installation iia aa 31 5 1 Types Of Installation 31 5 2 DINA MOUNTING tii a Ree hea A A A nae S 33 5 3 W AMOUNT A a 36 6 COMMOCUON AAE a EE E E E S 37 6 1 Rower SUPDIV a o de a tee as o a a a ah ne a tae tise 37 6 2 AU COMA t a a a EEST A NAR AAN Ea apa ASS AA TAANA GAETA 40 6 3 Connecting the SFP transceiver eiecit E E E 41 6 4 Grounding esii i ti dd cadence ae cad de did geen ag 41 7 Functional description and configuration using Web based Management ooooocccccnnnccccononccccnnnanccnnnananonons 43 SCALANCE X204RNA SCALANCE X204RNA EEC Oper
27. ALANCE X204RNA EEC Autonegotiation Autonegotiation means the automatic detection of the functionality of the port at the opposite end Using autonegotiation repeaters or end devices can detect the functionality available at the port of a partner device allowing automatic configuration of different types of device With autonegotiation two components connected to a link segment can exchange parameters and set themselves to match the supported communication functionality Note The SCALANCE X204RNA EEC operates permanently in autonegotiation mode and can therefore be connected to other devices that either also use the autonegotiation mode or the 100 Mbps mode FD full duplex Note The SCALANCE X204RNA EEC is a plug and play device that does not require settings to be made for commissioning MDI MDIX autocrossover function The advantage of the MDI MDIX autocrossover function is that straight through cables can be used throughout and external Ethernet crossover cables are unnecessary This prevents malfunctions resulting from mismatching send and receive wires This makes installation much easier for the user The SCALANCE X204RNA EEC supports the MDI MDIX autocrossover function Note Please note that the direct connection of two ports on the switch or accidental connection over several switches causes an illegal loop Such a loop can lead to network overload and network failures Transmission speed T
28. ARNING Danger from line voltage The SCALANCE X204RNA EEC has a power supply of 100 240 VAC or 24 250 VDC This product can only function correctly and safely if it is transported stored set up and installed correctly and operated and maintained as recommended Connecting and disconnecting may only be performed by an electrical specialist Connect or disconnect power supply cables only when the power is turned off A WARNING The SCALANCE X204RNA EEC does not have an ATEX approval Devices with 100 to 240 VAC power supply or 24 250 VDC are not approved for use in hazardous areas according to EC Dir 94 9 ATEX CAUTION Securing cables with dangerous voltage Make sure that the connector cannot be released accidentally by pulling on the connecting cable Lay the cables in cable ducts or cable channels and secure the cables where necessary with cable ties Grounding WARNING PE connection with SCALAMCE X204RNA EEC Grounding simply via the housing is inadequate For safe operation the protective ground must be connected to the grounding bolts On the SCALANCE X204RNA EEC the PE connector is on the bottom of the device SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 39 Connection 6 2 Signaling contact 6 2 Signaling contact Signaling contact The signaling contact relay contact is a floating switch with which error fault states can
29. B Packet Type Packet Error PRP Figure 7 31 Packet Type Statistic Graphic With the check box in the Packet Type column you decide the content of the graphic The value in the Packets column in the graphic is only displayed for a certain packet type if the appropriate check box is selected The Percentage column shows the packets of a certain type as a percentage of the total packets for this port When the percentage is calculated packet types are included only if their check boxes are selected With the Previous Port and Next Port buttons you can change to the display of the previous or next port 7 8 8 Packet Error Statistic Errors in received packets The Packet Error Statistics page shows how many bad frames were received per port The following error types are distinguished e Bad Frames Total number of bad received frames e CRC Number of frames whose content did not match the CRC checksum e Undersize Number of frames with a length less than 64 bytes SCALANCE X204RNA SCALANCE X204RNA EEC 86 Operating Instructions Functional description and configuration using Web based Management 7 8 The Switch menu e Oversize Number of frames with a length greater than 1536 bytes e Dropped L2 Number of frames that were discarded at the receiving port due to lack of resources on the switch If you click the Reset Counters button you reset the counters for all ports SIEMENS Automati
30. B005G unmanaged IE Switch for 10 100 1000 Mbps 6GK5005 0GA00 1AB2 ES 01 SCALANCE XB008 unmanaged IE Switch for 10 100 Mbps 6GK5008 0BA00 1AB2 ES 01 SCALANCE XB008G unmanaged IE Switch for 10 100 1000 Mbps 6GK5008 0GA00 1AB2 ES 01 SCALANCE X104 2 unmanaged IE Switch 6GK5104 2BB00 2AA3 ES 01 SCALANCE X106 1 unmanaged IE Switch 6GK5106 1BB00 2AA3 ES 01 SCALANCE X108 unmanaged IE Switch 6GK5108 0BA00 2AA3 ES 01 SCALANCE X108POE unmanaged IE Switch 6GK5108 0PA00 2AA3 ES 01 SCALANCE X112 2 unmanaged IE Switch 6GK5112 2BB00 2AA3 ES 01 SCALANCE X116 unmanaged IE Switch 6GK5116 OBA00 2AA3 ES 01 SCALANCE X124 unmanaged IE Switch 6GK5124 0BA00 2AA3 ES 01 SCALANCE X200 4P IRT managed IE IRT Switch POF 6GK5200 4AH00 2BA3 ES 01 SCALANCE X201 3P IRT managed IE IRT Switch POF 6GK5201 3BH00 2BA3 ES 01 SCALANCE X201 3P IRT managed IE IRT Pro Switch new 6GK5201 3JRO00 2BA6 ES 01 SIMATIC NET SCALANCE X202 2 IRT managed IE Switch 6GK5202 2BB00 2BA3 ES 01 SIMATIC NET SCALANCE X202 2P IRT managed IE IRT Switch POF 6GK5202 2BH00 2BA3 ES 01 SIMATIC NET SCALANCE X202 2P IRT AIDA 6GK5202 2JR00 2BA6 ES 01 SIMATIC NET SCALANCE XF204 managed IE Switch 6GK5204 0BA00 2AF 2 V4 4 SIMATIC NET SCALANCE X204 2 IRT managed IE Switch 6GK5204 0BA00 2BA3 ES 01 SIMATIC NET SCALANCE XF204 IRT managed IE Switch 6GK5204 0BA00 2BF2 ES 01 SIMATIC NET SCALANCE X204 IRT AIDA 6GK5204 0JA00 2BA6 ES 01 SIMATIC NET SCALANCE X204 2 managed IE Switch 6GK5204 2BB1
31. BC 2 x 3 Switch 3 08 00 06 10 08 31 A B x Ports E FDB Statistics Figure 7 27 Switch Forwarding Database The five columns of the table display the following information Index Index of the entry Mac Address Learnt MAC address Destination Ports Specifies the destination port via which a frame with the learnt destination MAC address must be output Duplicate filter Shows whether the MAC address is listed as a source MAC address in the duplicate filter table SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 81 Functional description and configuration using Web based Management 7 8 The Switch menu Proxy node Shows whether the MAC address is listed as a source MAC address in the proxy node table 7 8 5 the Statistics menu Counting and evaluation of received frames A SCALANCE X 204RNA has internal statistics counters with which it counts the number of received frames for each port according to the following criteria e Frame length e Message frame type e Bad frames This information provides you with an overview of the data traffic and any problems on the network 7 8 6 Packet Size Statistic Received frames sorted by length The Packet Size Statistics page displays how many packets of which size were received at each port If you click the Reset Counters button you reset the counters for all ports SCALANCE X204RNA SCALANCE X204RNA EEC 82 Operating Instructions Functi
32. E X204RNA SCALANCE X204RNA EEC Operating Instructions 69 Functional description and configuration using Web based Management 7 7 The Agent menu SIEMENS Automation amp Drives Console e Support e Logout Power CPU Status Status Status Status SIMATIC NET tet SIMATIC NET Industrial Ethernet SCALANCE X204RNA EEC DE PA DPS OP1 EP20 192 168 1 1 PE X204 RNA EEC Agent SNMP Configuration System 32200 7 A Agent SNMPv1 v2c i SNMP Event Config D O Read Only Time Config a switch O Traps Refresh Set Values Figure 7 18 Agent SNMP Configuration SNMPv1 v2c Here you enable disable SNMPv1 v2c for a SCALANCE X 200RNA Read Only When this check box is selected you can only read SNMP variables with SNMPv1 v2c Traps This enables disables the sending of SNMPv1 v2c traps 7 7 3 SNMP Trap Configuration SNMP traps for alarm events If an alarm event occurs a SCALANCE X 200RNA can send traps alarm frames to up to 10 different network management stations at the same time Traps are only sent when events as specified in the Agent Event Configuration menu occur see Section Agent Event Configuration Page 73 Note Traps are sent only when the Traps option was selected in SNMP Configuration SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 70 Functional description and configuration using Web based Management 7 7 The Agent menu SIEMENS Suppo
33. Load Firmware and Restart or Load FPGA File and Restart Following the download there is an automatic restart and the device starts up with the new data SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 53 Functional description and configuration using Web based Management 7 5 The System menu How to save data using HTTP 1 Start the save function by clicking either the Save Configuration or Save Private MIB button 2 You will be prompted to select a storage location and a name for the file or to accept the proposed file name Reusing configuration data Saving and reading in configuration data reduces the effort if several SCALANCE X 200RNA devices have the same configuration and when IP addresses are obtained over DHCP Save the configuration data on your computer after you have configured a SCALANCE X 200RNA Download this file to all other SCALANCE X 200RNA devices you want to configure If individual settings are necessary for specific devices these must be made online The stored configuration data is coded and as a result these files cannot be edited with a text editor SCALANCE X204RNA SCALANCE X204RNA EEC 54 Operating Instructions Functional description and configuration using Web based Management 7 5 The System menu 7 5 5 System Version Numbers Versions of hardware and software This page shows the versions of the hardware and software with which the SCALANCE X 200RNA is being
34. MATIC NET Power CPU Status Status Status Status SIMATIC NET Industrial Ethernet uff O SCALANCE X204RNA EEC PA O P8 O P1 O P2 o 192 168 1 1 X204 RNA EEC Agent Time Configuration System x200 System Time 09 22 2011 14 47 29 Sa Agent Time Synchronization manually 3 SNMP E Trap Config E Timeout Config SNTP Mode Poll Event Confi be SNTP Server IP Address 0 0 0 0 Time Config 9 switch SNTP Server Port 123 Time Zone SNTP Server Time Mi Init Poll Interval ms 1000 Poll Interval min 1 Refresh Set Values Figure 7 24 Agent Time Configuration System Time This box displays the current system time If no time of day synchronization was possible the box displays Date time not set You can also set the date and time manually the required input format is MM DD YYYY HH MM SS In this case the text box displays the data and time along with the suffix m If the system time was set as a result of synchronization with a server the suffix is p Time Synchronization This box is read only and shows when the last time of day synchronization took place SNTP Mode The protocol type used is displayed here e Poll If you choose this protocol type you have to define further settings Time zone offset Time server Init poll interval Poll interval SCALANCE X204RNA SCALANCE X204RNA EEC 76 Operating Instructions Functional description and configuration using Web based Management
35. NTP Note The networks LAN A and or LAN B can have PROFINET or IRT functionality These cannot however be transferred via the SCALANCE X 200RNA because PRP does not support this PRP functionality is not impaired by using PROFINET or IRT components in the LAN A and LAN B networks SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 15 Product characteristics 4 1 Overview of the product characteristics Table 4 2 Overview of the connection options Fast Ethernet Device type SCALANCE 100 Mbps X204RNA X204RNA EEC TP RJ 45 4 2 2 Fiber 2 x SFP modules SFP991 1 multimode multimode glass up to 3 km 6GK5991 duplex LC 1AD00 8AA0 Fiber 2 x SFP modules SFP991 1LD single mode monomode glass up to 26 km duplex LC 6GK5991 1AF00 8AA0 Fiber 2 x SFP modules SFP991 1LH single mode monomode glass up to 70 km duplex LC 6GK5991 1AE00 8AA0 Ports P1 P2 P1 P2 PRP ports PRP A PRP B PRP A PRP B Note TP connectors of SCALANCE X204RNA EEC 2 x RJ 45 for connecting two end devices network structures without PRP 1 capability and optionally 2 x RJ 45 or 2 x SFP modules for connecting network structures capable of PRP If an SFP module is inserted the corresponding RJ 45 jack is disabled Example If SFP module PRP A is inserted the TP Interface PRP A has no function SCALANCE X204RNA SCALANCE X204RNA EEC 16 Operating Instructions Product characteristic
36. Operating Instructions Technical data 9 1 Technical specifications Table 9 1 Construction Device type Dimensions W x H x D in Weight in g Installation options SCALANCE mm DIN rail Wall mounting X204RNA 45 x 100 x 87 230 X204RNA EEC 70 x 147 x 123 780 without protective bracket 70 x 189 x 123 with protective bracket without protective bracket with protective bracket 800 Wall mounting with DIN rail possible Table 9 2 Ports Device type Connectors end Connections for end Connectors for the Connectors for the SCALANCE devices or network devices or network power supply signaling contact components via components via FO Plug in terminal block Plug in terminal block twisted pair cable RJ 45 jacks with MDI Duplex LC connector X pinning 100 Mbps with SFP module full duplex X204RNA 4 1 x 4 pin 1 x 2 pin X204RNA EEC 2 2 max 2 1 x 3 pin 1 x 3 pin SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 97 Technical data 9 1 Technical specifications Overvoltage protection at input Fuse 2 A FF can only be replaced in factory Fuse 1 25 A can only be replaced in factory Connectors for the signaling contact 1 x 2 pin 1 x 3 pin 0 100m IE FC TP standard cable with IE FC RJ 45 plug 180 over IE FC outlet RJ 45 with 0 90 m IE FC TP standard cable 10 m TP cord Table 9 3 Electrical data Device type Supply voltage Pow
37. RNA EEC PA O P8 OPI O P2 0 192 168 1 1 SEN J X204 RNA EEC Select Set Button Configuration 2 System 18M Enable Select Set Functions Restart amp Defaults Save amp Load HTTP E Version Numbers Enable Disable Reset Restore Factory Defaults Passwords Set Fault Mask B Select Set Button Event Log x200 7 Agent 9 Switch Figure 7 10 Select Set button configuration SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 57 Functional description and configuration using Web based Management 7 5 The System menu Enable Select Set Functions You can enable or disable the individual functions of the button by checking or unchecking the relevant box You apply your settings with Set Values 7 5 8 System Event Log Table menu Logging events 58 A SCALANCE X 200RNA allows you to log events and to display them on the page of the Log Table menu This for example allows you to record when an SNMP authentication attempt failed or when the connection status of a port has changed You can specify which events are logged in the Agent Event Configuration menu item SIEMENS Automation amp Drives Console Support Logout SIMATIC NET Power CPU Status Status Status Status u a SIMATIC NET Industrial Ethernet eer SCALANCE X204RNA EEC PA D P8 MPi EP o 192 168 1 1 C 204 RNA EEC System Event Log Table 1 System S leM m 02 47 21 075 2011 10 24 04 46 58 m DIAG 3 ON P2 Link d
38. Requirements for Web Based Management e ASCALANCE X 200RNA must have an IP address before you can use Web Based Management e To use Web Based Management there must be an Ethernet connection between the SCALANCE X 200RNA and the client computer e Use of a Microsoft Internet Explorer version 8 or higher is recommended e All the pages of Web Based Management require JavaScript You should therefore make sure that Java Script is enabled in your browser settings Note The browser must not be set so that it reloads the page from the server each time the page is accessed The updating of the dynamic content of the page is ensured by other mechanisms In the Internet Explorer you can make the appropriate setting in the Options gt Internet Options gt General menu in the section Temporary Internet Files with the Settings button Below the text Check for newer versions of stored pages the Automatically check box must be selected e Web Based Management is HTTP or HTTPS based so you must also enable access to port 80 or 443 if you have a firewall installed SCALANCE X204RNA SCALANCE X204RNA EEC 44 Operating Instructions Functional description and configuration using Web based Management 7 2 Prerequisite Starting Web Based Management and logging on 1 Enter the IP address in the address box of the Web browser If there is a problem free connection to the SCALANCE X 200RNA the Logon screen of Web Based Management
39. SIEMENS SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions Introduction Safety notes Network topologies and redundancy Product characteristics Installation Connection O O A W IN Functional description and configuration using Web based Management Approvals and marking Technical data Accessories and compatible devices 10 References 11 Dimension drawings 12 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety as well as to prevent damage to property The notices referring to your personal safety are highlighted in the manual by a safety alert symbol notices referring only to property damage have no safety alert symbol These notices shown below are graded according to the degree of danger indicates that death or severe personal injury will result if proper precautions are not taken A WARNING indicates that death or severe personal injury may result if proper precautions are not taken CAUTION with a safety alert symbol indicates that minor personal injury can result if proper precautions are not taken CAUTION without a safety alert symbol indicates that property damage can result if proper precautions are not taken NOTICE indicates that an unintended result or situation can occur if the relevant information is not taken into ac
40. SIMATIC NET i eF a SIMATIC NET Industrial Ethernet SCALANCE X204RNA EEC PA P8 O P1 B P2 0 192 168 1 1 searen X204 RNA EEC X200 Status a System al x200 a Agent Y Switch Power Line 1 up Fault Status no Fault Figure 7 12 X200 Status Power Line 1 e Up Power supply 1 line 1 is applied e Down Power supply 1 is not applied or is below the permitted voltage Power Line 2 SCALANCE X204RNA only not illustrated SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 60 Functional description and configuration using Web based Management 7 6 The X200 menu e Up Power supply 2 line 2 is applied e Down Power supply 2 is not applied or is below the permitted voltage Fault Status The fault status of the SCALANCE X 200RNA is shown here The following table contains examples of possible error messages If more than one problem has occurred they are listed in the text box one above the other Error messages Meaning Redundant power line down The redundant power supply has failed Link down on monitored port The connection to a monitored port is interrupted No Fault The SCALANCE X 200RNA has not detected a fault the signaling contact has not responded and the fault LED is not lit SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 61 Functional description and configuration using Web based Management 7 6 The X200 menu
41. Simple Network Time Protocol SNTP System Up Time read only The time since the last reboot Device Type read only The type designation of the device SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 49 Functional description and configuration using Web based Management 7 5 The System menu System Contact Enter the name of a contact person responsible for managing the device in this box System Location In this box you enter a location for the device for example a room number System Name Enter a description of the device in this box 7 5 2 System Identification amp Maintenance System Identification 8 Maintenance The following screen contains information on device specific vendor and maintenance data such as the order number serial number version numbers etc SIEMENS Automation amp Drives Console Support e Logout SIMATIC NET Power CPU Status Status Status Status ui a SIMATIC NET Industrial Ethernet SCALANCE X204RNA EEC PA O PB O PI MP2 0 192 168 1 1 EA X204 RNA EEC System Identification amp Maintenance 1 System B ism E Restart amp Defaults Manufacturer ID SIEMENS E Save amp Load HTTP E Version Numbers Order ID Passwords Serial Number Select Set Button Hardware Revision a Event Log Software Revision 3 0 53 x200 Agent 3 switch Revision Date Sep 21 2011 Figure 7 5 System Identification amp Maintenance I amp M O Here
42. Speed Redundancy Hypertext Transfer Protocol Protocol for transfer from Web sites Media redundancy Method for increasing availability in Industrial Ethernet networks in which devices can be reached over different paths This might be achieved by meshing networks arranging parallel transmission paths or by closing a linear bus topology to form a ring Media redundancy within a ring topology is available with SIMATIC NET products with the gt HSR and gt MRP methods Media Redundancy Protocol 114 A method specified in the IEC 61158 Type 10 standard for increasing network availability in a ring topology See also gt Media redundancy SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions Glossary MIB Mirroring MRP Multicast Multimode PRP RMON Managed Information Base A tree structure containing all the data relevant for network management in SNMP A port mirror port with its specific data traffic can be mirrored to another port monitor port for test purposes Protocol analysis devices can be connected to the monitor port in other words the monitor port is not available for data exchange Mirroring has no effect on the mirror port gt Media Redundancy Protocol A frame with a multicast address is received by all nodes prepared to receive this address In multimode transmission the pulse is transferred using many modes waves that travel along curved paths or are reflected withi
43. T ma CPU Status Status Status Status SIMATIC NET Industrial Ethernet SCALANCE X204RNA EEC PA D PB O P1 DP2 o 192 168 1 1 2204 RNA EEC Packet Size Statistic Graphic 1 System 9 x200 Port 9 Agent 56 Switch Percentage A Pors Ga Statistics z Packet Size 2 32 E PRP Total Figure 7 29 Packet Size Statistic Graphic With the check box in the Packet Size column you decide the content of the graphic The value in the Packets column in the graphic is only displayed for a certain range if the appropriate check box is selected The Percentage column shows the packets in a certain length range as a percentage of the total packets for this port When the percentage is calculated ranges are included only if their check boxes are selected With the Previous Port and Next Port buttons you can change to the display of the previous or next port 7 8 7 Packet Type Statistic Received frames sorted by type The Packet Type Statistics page displays how many frames of the type unicast multicast and broadcast were received and sent at each port If you click the Reset Counters button you reset the counters for all ports SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 84 Functional description and configuration using Web based Management 7 8 The Switch menu SIEMENS Automation amp Drives e Console 4 Support Logout Power CPU Status Status Status Status lt E SIMATIC NET Industria
44. The following safety notices must be adhered to when setting up and operating the device and during all associated work such as installation connecting up replacing devices or opening the device A WARNING Safety extra low voltage The SCALANCE X204RNA is designed for operation with Safety Extra Low Voltage SELV by a Limited Power Source LPS This does not apply to the SCALANCE X204RNA EEC This means that only SELV LPS complying with IEC 60950 1 EN 60950 1 VDE 0805 1 must be connected to the power supply terminals The power supply unit for the equipment power supply must comply with NEC Class 2 as described by the National Electrical Code r ANSI NFPA 70 If the equipment is connected to a redundant power supply two separate power supplies both must meet these requirements A WARNING The maximum current via the terminals is 10 A You should therefore include a fuse that trips at a current higher than 10 A The fuse must meet the following requirements Suitable for min 300 VDC 250 VAC max 10 A Breaking current at least 10 kA UL CSA listed UL 248 1 CSA 22 2 No 248 1 As an alternative the following requirements Breaking current at least 10 kA Approved in compliance with IEC 60127 1 EN 60127 1 Breaking characteristics B or C for a circuit breaker or slow blow fuse SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions Safety notes 2 1 Safet
45. a C PLUG has been taken out of a device when the device is restarted an error message is output in Web Based Management and in the Command Line Interface In this case you will need to set the device to operation without C PLUG For further information refer to the section System C PLUG WBM menu SCALANCE X204RNA SCALANCE X204RNA EEC 26 Operating Instructions Product characteristics 4 7 SET button 4 7 SET button SET button Button function You can change various device settings with the button Modified settings are retained after device power off on The SELECT SET button is used to switch over the display mode and to make other settings After turning on the SCALANCE X 200RNA it is in the display mode The button has three functions e Triggering a device restart e Reset to the factory defaults All settings made are overwritten by the factory defaults e Define the fault mask and the display at the LEDs The current states of all ports and the states of the power supplies L1 and L2 are included in the fault mask The previous fault mask is then overwritten Different settings are made depending on how long you hold down the button Phase1 Phase2 Phase3 Phase4 Phased o a Rao Via VES Os as 6s 8s 10s Figure 4 5 The five button phases Time the button is pressed in seconds Table 4 6 Button phases Phase Description 1 The currently set fault mask is displayed If no fault mask has b
46. able outlet 6GK5324 0GG00 3HR2 V3 7 0 at rear SCALANCE XR324 4M EEC MANAGED IE SWITCH 1 X 24 VDC 6GK5324 4GG00 1ER2 V3 7 0 cable outlet front SCALANCE XR324 4M EEC MANAGED IE SWITCH 2 X 24 VDC 6GK5324 4GG00 2ER2 V3 7 0 cable outlet front SCALANCE XR324 4M EEC MANAGED IE SWITCH 1 X 24 VDC 6GK5324 4GG00 1JR2 V3 7 0 cable outlet at rear SCALANCE XR324 4M EEC MANAGED IE SWITCH 2 X 24 VDC 6GK5324 4GG00 2JR2 V3 7 0 cable outlet at rear SCALANCE XR324 4M POE MANAGED IE SWITCH 24 VDC cable 6GK5324 4QG00 1AR2 V3 7 0 outlet front SCALANCE XR324 4M POE MANAGED IE SWITCH 24 VDC cable 6GK5324 4QG00 1HR2 V3 7 0 outlet at rear SIMATIC NET SCALANCE X408 2 modular IE switch 6GK5408 2FD00 2AA2 V3 7 0 SIMATIC NET SCALANCE X414 3E modular IE switch 6GK5414 3FC00 2AA2 V3 7 0 SIMATIC NET CSM module 1277 6GK7277 1AA10 OAAO ES 01 S7 1200 SIMATIC NET CSM module 377 6GK7377 1AA00 OAAO ES 01 S7 300 SCALANCE XR552 12M MANAGED IE SWITCH 6GK5552 0AA00 2AR2 1 0 SCALANCE XR528 6M MANAGED IE SWITCH 6GK5528 0AA00 2AR2 1 0 CP 343 1 Lean 6GK7343 1CX10 0XEO V2 4 CP 343 1_Bacnet 6FL4 343 1CX10 OXE0 V1 1 CP 343 1_STD 6GK7343 1EX30 0XE0 V2 4 CP 343 1 Adv 6GK7343 1GX30 0XE0 V1 2 CP 343 1_Adv 3 0 6GK7343 1GX31 OXE0O V3 0 CP 443 1_Adv 6GK7443 1GX20 0XE0 V2 1 CP 443 1_Adv 6GK7443 1GX30 0XE0 V3 0 CP 443 1 6GK7443 1EX20 0XE0 V2 1 CP 443 1 6GK7443 1EX30 0XE0 V3 0 Explanation SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions
47. ating Instructions 3 Table of contents 10 11 7 1 INTO UCI AA A A A A A O A E ade a a 43 7 2 Prerequisite Mit tt dd a dd dl es Alas Moe Mt seat A ok he 44 7 3 LED simulation of the WBM iii tt de haber tas 46 7 4 Working with the WBM ccccceeeeeeeeeeceaeee ce aa aa aae a aa a aeaa 48 7 5 The System MeNUiiiniconiotaac it tidad dida idad ng Aiea delia idad abba bad gica needs 49 7 5 1 System Configuratlone ys criti aise dada 49 7 5 2 System Identification amp Maintenance oonocccnnonicccnnnoccccnnnoncnccnnoncnn nano cnn c nano nn nr naar narran rca rra 50 7 5 3 System Restart amp Defaults ici id da 51 7 5 4 System Save amp LOA ici ci eo 52 7 5 5 System Version NUMDETS p rrn randana e sata ln eee mia ee 55 7 5 6 System Pass Wo ced a ETE a suede dave sie A E easiest a AE TE AEA 56 7 5 7 System Select Set Button ici census a anes nd ee ee ee i 57 7 5 8 System Event Log Table Menu ccccccccccceceeeeeeeeeneceeeeeee seca eaaeeeeeeeeesecceaeeeeeeeeesecsesaeeeeeeeeneees 58 7 6 THE X200 MENU io aba 60 7 6 1 X200 Stat s aora lisis ta lianas E E edi tad 60 7 6 2 PRP configuration iia ii ss 62 7 6 3 FaultMask 1 eta loa at on 63 7 7 The Agent Menu iii A A cee are eed evi neta een 67 7 7 1 Agent Configuration eco atest aired fad exe anne eee aad dad dee ene 67 7 7 2 Agent SNMP Configuration cccccceceeeeeceeaeceeeeecececaaeaeeeeeeeceeeaaeceeeeeeesecsaaaeseeeeeeesecsenaeeneees 69 7 7
48. ault tolerant networks PRP provides bumpless redundancy This redundancy procedure allows data communication to be maintained without interruption if there are interruptions in the network Other redundancy procedures have a reconfiguration time of the network of for example 200 ms MRP 50 nodes in the ring or 300 ms HSR 50 nodes in the ring and can therefore not be used for substation applications or other applications that require high network availability The PRP method has the advantage that it uses parallel separate networks made up of standard network components The end devices that use this method are connected to the two networks via a preceding device or via two integrated device interfaces This means that the frame of the end device can be transferred at the same time via both networks If a transmission path is interrupted the frame arrives at its destination via the second path The devices of the SCALANCE X 200RNA family are used to connect end devices without integrated PRP 1 interfaces to parallel networks Which topologies can be implemented With the SCALANCE X 200RNA devices nodes or entire network segments without PRP 1 capability can be connected to a Parallel Redundancy Protocol network The SCALANCE X 200RNA products with their PRP capability can be used to implement an integrated solution for network components and protective devices for a substation and also process application The SCALANCE X 200RNA can
49. bled Active Indicates whether or not the port is turned on true or turned off false Data traffic is possible only over an enabled port The communications partner of a port that is turned off indicates the connection status Link Down Link Status of the link to the network The following alternatives are possible e Up The port has a valid link to the network a link integrity signal is being received e Down The link is down for example because the connected device is turned off SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions Functional description and configuration using Web based Management 7 8 The Switch menu 7 8 4 Switch Forwarding Database Display of the Switch Forwarding Database The Switch Forwarding Database screen appears if you click the FDB folder icon The screen shows the dynamically learnt MAC addresses in the FDB table for all ports In addition to this to allow PRP diagnostics the screen also shows whether the displayed MAC addresses are listed in the duplicate filter or in the proxy node table SIEMENS Automation amp Drives Console Support Logout SIMATIC NET oe CPU Status Status Status Status SIMATIC NET Industrial Ethernet SCALANCE X204RNA EEC PaO P8 OP1 OP2 oO 192 168 1 1 E 2204 RNA EEC Switch Forwarding Database E System x200 Index Mac Address Destination Ports Duplicate Filter Proxy Node a 1 00 0E 8C 90 BD DE A x 17 Agent 2 00 40 F4 70 F0
50. ce This means that the configuration data remains available if the basic device is replaced Power is supplied by the basic device The C PLUG retains all data permanently when the power is turned off If an empty C PLUG factory settings is inserted all configuration data of the SCALANCE X 200RNA is saved to it when the device starts up Changes to the configuration during operation are also saved on the C PLUG without any operator intervention being necessary If a C PLUG is inserted the configuration stored internally on the basic device is no longer changed Al changes made to the configuration during ongoing operation are only stored on the C PLUG A basic device with an inserted C PLUG automatically uses the configuration data of the C PLUG when it starts up This is however only possible when the data was written by a compatible device type This allows fast and simple replacement of the basic device If a device needs to be replaced the C PLUG is simply taken from the failed component and inserted in the replacement device The first time it is started up the replacement device has the same configuration as the failed device except for the MAC address set by the vendor Compatible devices As a general rule the data on the C PLUG is only compatible with devices having an identical order number and the same device name Over and above this the data of the SCALANCE X204RNA and the SCALANCE X204RNA is compatible Using a
51. ces Note Provide suitable shade to protect the SCALANCE X 200RNA devices against direct sunlight This avoids unwanted warming of the SCALANCE X 200RNA devices and prevents premature aging of the device and cabling A WARNING If a SCALANCE X204RNA EEC is operated at ambient temperatures between 60 C and 70 C the housing temperature may exceed 70 C When installing the X204RNA EEC select a location where only qualified service personnel or trained users have access to it Operation of the SCALANCE X204RNA EEC at ambient temperatures of 60 C 70 C is only permitted under these conditions A WARNING If the cable or conduit entry point exceeds 70 C or the branching point of conductors exceeds 80 C special precautions must be taken SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 31 Installation 5 1 Types of installation NOTICE Do not cover the ventilation grilles During installation select a mounting position so that the ventilation grilles are always free to achieve adequate cooling In the standard position the ventilation grilles are on the top bottom and sides X204RNA EEC only of the housing Minimum clearances If you install the SCALANCE X 200RNA in a control cabinet without forced ventilation or cooling minimum clearances must be maintained to neighboring devices or the wall of the enclosure By keeping to the minimum clea
52. ces in these operating instructions The descriptions in these operating instructions always apply to the devices of the SCALANCE X 200RNA product line listed under Validity of the Operating Instructions in this document unless the description relates to a specific device of the product line Further documentation The SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks manual contains additional information on other SIMATIC NET products that you can operate along with the devices of the SCALANCE X 200 product line in an Industrial Ethernet network SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 7 Introduction 1 1 Introduction Finding information To help you to find the information you require more quickly the manual includes not only the table of contents but also the following sections in the Appendix e Index e Glossary Audience These Operating Instructions are intended for persons commissioning Ethernet networks with the Parallel Redundancy Protocol PRP Standards and approvals The devices of the SCALANCE X 200RNA product line meet the requirements for the CE mark You will find detailed information in the section Approvals and markings in these operating instructions SCALANCE X204RNA SCALANCE X204RNA EEC 8 Operating Instructions Safety notes 2 2 1 Safety notices Important notes on using the device Safety notices on the use of the device General notices
53. cess connection point for connecting end devices network segments not capable of PRP to parallel networks Rapid Spanning Tree protocol Variant of the Spanning Tree protocol optimized for speed This protocol prevents loops forming in multiple redundant network connections If there is an interruption on a connection the network is automatically reconfigured so that there is exactly one connection between all nodes gt SSH Secure Socket Layer Segment SFF SFP Signaling contact 116 gt SSL In the Ethernet bus system transceivers connected together over the bus cable along with the nodes connected over patch cables form a segment Several such segments can be connected via repeaters When using twisted pair and fiber optic cables each subsection forms a segment Small Form Factor The SFF slot is used to insert SFP modules See also SFP Small Form Factor Pluggable SFP is a specification for modular optical or electrical transceivers for network connections SFP modules fit in an SFF slot and can be replaced simply and quickly hot swapping Floating relay contact via which the detected error states can be signaled SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions Glossary Single mode SNMP SNTP SSH SSL In single mode transmission and monomode transmission the pulse is transmitted by a straight mode wave Attenuation is mainly caused by physical absorption and dispersio
54. col A simple UDP based protocol for data transfer Due to its limited size it can also be used by network nodes with little ROM SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 117 Glossary TP Twisted Pair TP port Port with a TP connector RJ 45 jack WBM Web Based Management With WBM configuration and diagnostics are handled with an Internet browser Entries made by the user are sent to the device using the HTTP protocol and the device transfers its replies by HTTP to the user SCALANCE X204RNA SCALANCE X204RNA EEC 118 Operating Instructions Index A Aging time 82 ATEX 10 94 ATEX95 7 Autonegotiation 19 24 83 C Certifications and approvals 8 Connector pinout SCALANCE X204RNA 13 18 SCALANCE X204RNA EEC 23 C Tick approval 95 C Tick mark 8 D DCP 71 DCP Read Only 71 Declaration of conformity 93 Default gateway 71 Displays Fault display 30 Port status indication 31 Power display 30 E EMC directive 93 Error Bad Frames 89 CRC 89 Dropped L2 90 Oversize 90 Undersize 89 F Factory Defaults 56 Fault mask 66 FM approval 95 SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions H Hazardous Ex area 9 IP address 70 K Kc approval 96 L LED simulation 50 M MDI MDIX autocrossover function 19 24 N Network topology 11 Parallel Redundancy Protocol 12 P Port Port configuration 82 Possible attachme
55. count If more than one degree of danger is present the warning notice representing the highest degree of danger will be used A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage Qualified Personnel The product system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Trademarks Note the following A WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufacturers are used these must be recommended or approved by Siemens Proper transport storage installation assembly commissioning operation and maintenance are required to ensure that the products operate safely and without any problems The permissible ambient conditions must be complied with The information in the relevant documentation must be observed All names identified by are registered trademarks of Siemens AG The remaining trademarks in this publication may be trademarks whose use by third partie
56. e type SCALANCE LED lit green LED lit yellow LED flashes yellow Number of LEDs X204RNA 2 port LEDs 1 2 3 4 2 PRP port LEDs 1 2 3 4 X204RNA EEX 2 port LEDs 1 2 3 4 2 PRP port LEDs 1 2 3 4 TP link exists no data reception TP link data received at TP port Device startup the LED is lit for approx 6 seconds Bb OO N gt Setting or display of the fault mask 4 8 4 LED displays during startup LED displays during startup When a device starts up the following displays light up in the order shown 1 Power LEDs green light up immediately after turning on the power 2 Port LEDs go off the red error LED is lit for approx 10 seconds 3 Following startup the correct link status is indicated by the port LEDs after approximately 5 seconds 4 The SCALANCE X 200RNA is now ready for operation SCALANCE X204RNA SCALANCE X204RNA EEC 30 Operating Instructions Installation 5 5 1 Types of installation Types of installation The SCALANCE X 200RNA devices can be mounted on a 35 mm DIN rail Wall mounting is also possible Note Installation on a SIMATIC S7 300 standard rail is not possible Note When installing and operating the device keep to the installation instructions and safety related notices in this description and in the SIMATIC NET Industrial Ethernet network manual Page 107 Unless stated otherwise the mounting options listed below apply to all SCALANCE X 200RNA devi
57. ection DIN rail mounting Page 33 SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions Connection 6 1 Power supply Power supply The power supply is connected using a 3 or 4 pin plug in terminal block Usable cable cross section 0 25 to 2 5 mm The power supply is non floating The signal cables of the Ethernet TP ports are floating Note Removing or inserting the power connector with the power on is not permitted Table 6 1 Pin assignment Pin number Pin assignment of the SCALANCE X204RNA Pin assignment of the SCALANCE X204RNA EEC 2 Lo 3 O 4 m Pin 1 L1 24 VDC PE Pin 2 M1 L1 24 V 250 VDC L1 100 V 240 VAC Pin 3 M2 N1 Pin 4 L2 24 VDC x Note Since the SCALANCE X204RNA EEC does not have a redundant power supply the power supply must be connected between L1 and N1 SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 37 Connection 6 1 Power supply A WARNING The SCALANCE X204RNA is designed for operation with safety extra low voltage SELV This means that only safety extra low voltages SELV complying with IEC950 EN60950 VDE0805 can be connected to the power supply terminals Measures must be taken to prevent transient overvoltages of more than 40 of the rated voltage This is the case if the devices are operated exclusively with SELV Safety Extra Low Voltage The power supply unit for the SCALANCE X204RNA power supply m
58. een configured differently The LED signals that the SCALANCE X 200RNA can adopt the following statuses Device type SCALANCE LED lit red LED lit yellow LED not lit X204RNA 1 2 3 4 5 6 7 X204RNA EEC 1 3 4 5 6 7 Link down event on a monitored port Failure of one of the two redundant power supplies C PLUG error Device startup the LED is lit for approx 20 seconds Internal error Aredundancy error was detected No problem has been detected by the SCALANCE X 200RNA NO oO fF WO DY gt 4 8 2 Power display Power display The LEDs signal the following statuses of the SCALANCE X 200RNA The status of the power supply is indicated by a green LED Device type SCALANCE LED lit green LED lit yellow LED not lit X204RNA 1 2 3 X204RNA EEC 4 5 1 Both L power supplies are connected redundant supply 2 One L power supply is connected non redundant supply 3 Power supply L1 and L2 are not connected or supply voltages are lt 14 V SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 29 Product characteristics 4 8 Displays 4 Power supply L is connected 5 Power supply L is not connected or the supply voltage is too low 4 8 3 Port status indication Port status indicator green yellow LEDs The LEDs signal the following port statuses of the SCALANCE X 200RNA The status of interfaces is indicated by two color LEDs Devic
59. een set all ports flash one after the other If you release the button in phase 1 this has no effect 2 The LEDs of the ports at which there is currently a link flash at 2 5 Hz If you release the button in phase 2 this has no effect 3 The LEDs of the ports at which there is currently a link and the LEDs of the connected power supply are lit permanently If you release the button in phase 3 the fault mask corresponding to the lit LEDs is adopted 4 All port LEDs flash at 2 5 Hz Releasing the button during this phase brings about a device restart soft reset 5 All port LEDs flash alternately yellow green at 2 5 Hz The device is reset to the factory defaults SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 27 Product characteristics 4 7 SET button Note On the SCALANCE X204RNA the button is located below the C PLUG compartment On the SCALANCE X204RNA EEC the button is on the top of the device in a recess next to the C PLUG compartment C PLUG O SET button Figure 4 6 Position of the C PLUG and SET button SCALANCE X204RNA SCALANCE X204RNA EEC 28 Operating Instructions Product characteristics 4 8 Displays 4 8 Displays 4 8 1 Fault indicator yellow red LED Fault indicator yellow red LED If the LED is lit red a SCALANCE X 200RNA has detected an error fault At the same time the signaling contact opens assuming that the response of the signaling contact has not b
60. er loss Current consumption SCALANCE tolerance range typ typ X204RNA 2 x 24 VDC SELV 3 5 W at 24 VDC 150 mA at 24 VDC Safety Extra Low Voltage 19 2 28 8 VDC X204RNA EEC 1 x 24 VDC 6 W at 240 VAC 110 mA at 240 VAC 24 250 VDC 25 mA at 250 VDC 19 2 300 VDC 150 mA at 100 VAC or 250 mA at 24 VDC 1x 240 VAC 50 60 Hz Overvoltage category II 100 240 VAC 85 276 VAC Table 9 4 Signaling contact Device type Voltage for the Current through the Contact type SCALANCE signaling contact signaling contact X204RNA max 24 VDC max 100 mA NC contact X204RNA EEC max 240 VAC max 100 mA Changeover contact Table 9 5 Permitted cable lengths copper Device type 0 55m 0 85m SCALANCE IE TP torsion cable with IE IE FC TP marine trailing FC RJ 45 Plug 180 or flexible FRNC festoon 0 45 m IE TP torsion cable food cable with IE FC RJ 45 or with IE outlet RJ 45 10m Plug 180 TP cord or 0 75 m IE FC TP marine trailing flexible FRNC festoon food cable 10 m TP cord over IE FC outlet RJ 45 X204RNA X204RNA EEC 98 SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions Technical data Table 9 6 SFP modules only for SCALANCE X204RNA EEC SFP module SFP991 1 Permitted cable lengths fiber optic 0 3 000 m Glass FO cable 62 5 125 um multimode glass fiber SFP module SFP991 1LD SFP module SFP991 1LH 0 26 000 m 9 1 Technical specitications 0 70 000 m G
61. event transient voltage surges of more than 40 of the rated voltage This is the case if you only operate devices with SELV safety extra low voltage Safety requirements Installation 100 240 VAC SCALANCE X204RNA EEC only Safety requirements for installation According to the IEC 61131 2 standard and therefore in accordance with the EU directive 2006 95 EC Low Voltage Directive the devices are open equipment and in accordance with UL CSA certification they are an open type To fulfill requirements for safe operation with regard to mechanical stability flame retardation stability and shock hazard protection the following alternative types of installation are specified Installation in a suitable cabinet Installation in a suitable enclosure Installation in a suitably equipped enclosed control room SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 11 Network topologies and redundancy 3 3 1 Network topology and redundancy Parallel Redundancy Protocol The Parallel Redundancy Protocol is a redundancy protocol for Ethernet networks lt is defined in Part 3 of the IEC 624339 standard The SCALANCE X 200RNA devices support the PRP 1 method In the remainder of the text PRP always stands for the PRP 1 protocol The areas of application of PRP are distributed real time applications with high reliability demands that depend on the high availability of the network Compared with classic f
62. f the Web browser SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions Functional description and configuration using Web based Management 7 5 The System menu SIEMENS Automation amp Drives Console Support e Logout SIMATIC NET Status Status Status Status SIMATIC NET Industrial Ethernet SCALANCE X204RNA EEC PA O P8 O P1oP2 o 192 168 1 1 E x204 RNA EEC System Save amp Load via HTTP 2J System 18M Configuration File Browse Save Configuration Restart amp Defaults B Save amp Load HTTP Version Numbers Firmware File Browse Passwords Select Set Button L Load Configuration and Restart Load Firmware and Restart El Event Log FPGA File Browse x200 Load FPGA File and Restart 7 Agent 259 switch Private MIB File Save Private MIB Figure 7 7 System Save 8 Load via HTTP Configuration File Name and directory path of the configuration file you want to load to the SCALANCE X 200RNA Firmware File Name and directory path of the file from which you want to load the new firmware FPGA File Name and directory path of the file from which you want to load the FPGA configuration How to download data using HTTP 1 In the relevant text box enter a name and directory path for the file from which you want to take the data 2 Start the download of the relevant file by clicking one of the buttons Load Configuration and Restart
63. hange parameters and set themselves to match the supported communication functionality Note The SCALANCE X204RNA operates permanently in autonegotiation mode and can therefore be connected to other devices that either also use the autonegotiation mode or the 100 Mbps mode FD full duplex Note The SCALANCE X204RNA is a plug and play device that does not require settings to be made for commissioning MDI MDIX autocrossover function The advantage of the MDI MDIX autocrossover function is that straight through cables can be used throughout and external Ethernet crossover cables are unnecessary This prevents malfunctions resulting from mismatching send and receive wires This makes installation much easier for the user The SCALANCE X204RNA supports the MDI MDIX autocrossover function Note Please note that the direct connection of two ports on the switch or accidental connection over several switches causes an illegal loop Such a loop can lead to network overload and network failures Transmission speed The transmission speed of the Fast Ethernet ports is 100 Mbps full duplex SCALANCE X204RNA SCALANCE X204RNA EEC 20 Operating Instructions Product characteristics 4 5 SCALANCE X204RNA EEC 45 SCALANCE X204RNA EEC 4 5 1 SCALANCE X204RNA EEC product characteristics SCALANCE X204RNA EEC product characteristics Possible attachments The SCALANCE X204RNA EEC has four RJ 45 jacks and two sl
64. he IE switch for the current page Storing entries with Set Values Pages in which you can make configuration settings have a Set Values button at the lower edge Click this button to save the configuration data you have entered on the IE switch Note Changing configuration data is possible only with the Administrator login SCALANCE X204RNA SCALANCE X204RNA EEC 48 Operating Instructions Functional description and configuration using Web based Management 7 5 The System menu 7 5 The System menu 7 5 1 System Configuration General device information This screen appears if you click the System folder icon SIEMENS Automation amp Drives w Console e Support Logout SIMATIC NET res CPU Status Status Status Status SIMATIC NET Industrial Ethernet oe SCALANCE X204RNA EEC PAO PB OP1 B P2 o 192 168 1 1 Ll x204 RNA EEC System Configuration 59 System Ex x200 Curent System Time Gi Agent System Up Time 3 Switch Device Type Device Description System Contact Siemens lA SC IC System Location Siemens lA SC IC System Name PRP Redundancy Box Refresh Set Values Figure 7 4 System Configuration Current System Time read only The system time is set either by the user or is synchronized by a time of day frame either SINEC H1 time frame or SNTP You can also see when and how it was set e m The setting was made manually e p The setting was made by the
65. he transmission speed of the Fast Ethernet ports is 100 Mbps full duplex 4 5 3 SCALANCE X204RNA EEC SPP interface SCALANCE X204RNA EEC SFP interface The SFF slots are used to insert suitable SFP modules Here the use of transceivers with an optical interface is particularly practical SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 23 Product characteristics 4 5 SCALANCE X204RNA EEC Transmission medium and range Table 4 5 SFP transceiver overview SFP transceiver SFP991 1 SFP991 1LD SFP991 1LH Transmission medium Multimode FO cable Monomode FO cable Monomode FO cable Wavelength 1310 nm 1310 nm 1310 nm Core diameter 50 or 62 5 um 9 um 9 um Outer diameter 125 um 125 um 125 um Maximum range 3 km 26 km 70 km Order number 6GK5991 1AD00 8AA0 6GK5991 1AF00 8AA0 6GK5991 1AE00 8AA0 Connectors Electrical connection SFF slot Optical connection Duplex LC connector Transmission speed The transmission speed of the optical Fast Ethernet ports is 100 Mbps Transmission technique The transmission mode for 100Base FX is specified in the IEEE 802 3 standard 24 SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions Product characteristics 4 6 C PLUG 4 6 C PLUG CPLUG configuration plug Area of application How it works The C PLUG is an exchangeable medium for storage of the configuration and project engineering data of the basic devi
66. if you click the Switch folder icon In this screen you specify the aging time of the SCALANCE X 200RNA SIEMENS Automation amp Drives e Console Support Logout SIMATIC NET Power CPU Status Status Status Status SIMATIC NET Industrial Ethernet ui mF a SCALANCE X204RNA EEC PAO PB OPI OPO 192 168 1 1 al x204 RNA EEC Switch Configuration 1 System X200 Aging Enabled Aging Time 1 555 sec 30 E Agent Switch Figure 7 25 Switch Configuration SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 78 Functional description and configuration using Web based Management Aging Enabled 7 8 The Switch menu A SCALANCE X 200RNA automatically learns the source addresses of the nodes connected to it This information is used in the SCALANCE X 200RNA to forward data frames to the nodes specifically involved This reduces the network load for the other nodes If a SCALANCE X 200RNA does not receive a frame whose source address matches a learnt address within a certain time it deletes the learnt address This mechanism is known as aging Aging prevents frames being forwarded incorrectly for example when an end device for example a programming device is connected to a different switch port If the check box is not enabled a SCALANCE X 200RNA does not delete learnt addresses automatically Aging Time sec Here you enter the time after which the SCALANCE X 200RNA deletes an address if it has not recei
67. iguration Event Trap LogTable Syslog Cold Warm Start Link Change Authentication Failure Power Error Fault State Change Redundancy Event Refresh Set Values Figure 7 22 Agent Event Configuration with the SCALANCE X204 RNA You can configure the reaction of the SCALANCE X 200RNA to the following events Cold Warm Start The SCALANCE X 200RNA was turned on or restarted by the user Link Change A port has failed or data traffic is being handled again over a port that had previously failed Authentication Failure There was an SNMP access with a bad password or inadequate access rights Power Error SCALANCE X204RNA only This event occurs only when the power supply line 1 and line 2 are monitored It indicates that there was a change to line 1 or line 2 Fault State Change The fault status has changed The fault status can relate to the activated port monitoring the response of the signaling contact or the power supply monitoring Redundancy Event There are two situations that are signaled as a redundancy error 1 If there is a difference in the number of PRP frames received from and A and B The fault is set It is reset if the difference in PRP frames received from LAN A and B remains almost the same 2 Ifa PRP B frame is received at PRP A or vice versa the error is set until no more incorrect frames are received for approximately 30 seconds 74 SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructio
68. isconnect all connected cables 2 Use a screwdriver to release the lower rail catch of the device and pull the lower part of the device away from the rail Figure 5 3 SCALANCE X204RNA removing from a DIN rail 35 mm SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 35 Installation 5 3 Wall mounting 5 3 Wall mounting Wall mounting of a SCALANCE X204RNA Preparation for wall mounting Wall mounting 1 For wall mounting use suitable mounting fittings for the wall for example for a concrete wall two plugs 6 mm diameter and 30 mm long 2 screws 3 5 mm diameter and 40 mm long 2 Connect the electrical cable connecting cables 3 Fit the connectors for the signaling contact 4 Insert the terminal blocks into the sockets on the SCALANCE X204RNA For more exact dimensions please refer to the section Dimension drawings Page 109 in the manual Note The wall mounting must be capable of supporting at least four times the weight of the SCALANCE X204RNA see Technical specifications Wall mounting of a SCALANCE X204RNA EEC 36 To mount the SCALANCE X 204RNA EEC on a wall secure an adequately long piece of DIN rail 35 mm to the wall For wall mounting use suitable mounting fittings for the wall for example for a concrete wall two plugs 6 mm diameter and 30 mm long 2 screws 3 5 mm diameter and 40 mm long Now mount the SCALANCE X 204RNA on the DIN rail as described in the s
69. l Ethernet SCALANCE X204RNA EEC PA O P8 OPI oP2 o 192 168 1 1 SIMATIC NET EA X204 RNA EEC Packet Type Statistic System 9 x200 Port Unicast In Unicast Out Multicast In Multicast Out Broadcast In Broadcast Out A A 0 0 0 1561 0 5 3 Agent B 0 0 0 1561 0 5 ji 4 3989 2921 0 0 5 0 a Switch 2 0 0 0 0 0 5 2 Ports E FDB Y Statistics E Packet Size B Packet Type E Packet Error E pre Reset Counters Figure 7 30 Packet Type Statistic If you click on an entry in the Port column the Packet Type Statistics graphic is displayed for the selected port You then see a configurable graphical representation of the counter value Graphic representation of the statistics This page displays the number of frames received at each port graphically The display depends on the packet type There is a separate element in the graphic for each of the following ranges e Unicast e Multicast e Broadcast SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 85 Functional description and configuration using Web based Management 7 8 The Switch menu SIEMENS Automation amp Drives Console e Support Logout SIMATIC NET Power CPU Status Status Status Status SIMATIC NET Industrial Ethernet a sl SCALANCE X204RNA EEC PA O Pe O P1 O P2 o 192 168 1 1 assesses X204 RNA EEC Packet Type Statistic Graphic 7 System 33 x200 Port 3 Agent Y Switch Statistics Packet Size Total
70. lass FO cable 10 125 um Glass FO cable 10 125 um single mode fiber MTBF single mode fiber 92 45 years 67 64 years Switching technique Store and forward Store and forward Relative humidity in operation lt 95 no condensation 95 no condensation Latency 5 us 5 us Operating altitude at max xx C ambient temperature 2000 m at max 56 C 3000 m at max 50 C 2000 m at max 56 C 3000 m at max 50 C Table 9 7 Degree of protection and MTBF Device type Degree of protection SCALANCE X204RNA IP20 X204RNA EEC IP20 Table 9 8 Switching properties Device type Max number of Aging time SCALANCE learnable addresses X204RNA 1023 30 s X204RNA EEC 1023 30s Table 9 9 Permitted ambient conditions Device type Operating Storage transportation SCALANCE temperature temperature X204RNA 40 C through 60 40 C through 70 C C X204RNA EEC 40 C through 70 40 C through 70 C C up to 85 C max 16 h Note Note the orientation of the installed SCALANCE X204RNA and X204RNA EEC If a SCALANCE X204RNA or X204RNA EEC are mounted on a vertical rail an ambient temperature of maximum 40 C is permitted SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 99 Technical data 9 1 Technical specifications SCALANCE X204RNA SCALANCE X204RNA EEC 100 Operating Instructions Accessories and compatible devices 10 1 Accessories Table 10 1 Accessories and order nu
71. le devices 3 sci Attell AA as sd A A ee 103 References aii AA A AAA A aiii 107 11 1 References e A A tos 107 SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions Table of contents 12 DIMENSION GrAWINGS iuocotccocicidodonaniad cdi cido acidos 109 12 1 DIMENSION AFAWINOS 2 a 109 AA AAAA IAN 113 Dd iii oidos 119 SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions Table of contents SCALANCE X204RNA SCALANCE X204RNA EEC 6 Operating Instructions Introduction 1 1 1 Introduction Overview of SCALANCE X 200RNA The SCALANCE X 200RNA product family is part of the SCALANCE X product family Below you will find a brief overview of this product family The SCALANCE X family comprises various product lines that complement each other and that are carefully tuned to specific automation tasks What is possible The devices of the SCALANCE X 200RNA product line allow the cost effective setup of Industrial Ethernet structures with Parallel Redundancy Protocol functionality Purpose of the Operating Instructions These Operating Instructions support you when commissioning networks with the devices of the product line SCALANCE X200RNA Validity of the Operating Instructions These Operating Instructions are valid for the following devices of the SCALANCE X 200RNA product line SIMATIC NET SCALANCE X204RNA 6GK5204 0BA00 2KB2 SIMATIC NET SCALANCE X204RNA EEC 6GK5204 0BS00 3LA3 Names of the devi
72. manage a maximum of 1023 MAC addresses Note Make sure that the maximum permitted cable lengths for the relevant devices are not exceeded You will find the permitted cable lengths in the technical specifications SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 13 Network topologies and redundancy 3 1 Network topology and redundancy Parallel Redundancy Protocol PG PC IPC with SOFTNET IE RNA Server with SOFTNET IE RNA Ml Industrial Ethernet LAN A MA Industrial Ethernet LAN B SCALANCE an X204RNA SIPROTEC SCALANCE X204RNA SIMATIC S7 400 PC G_IK10_XX_10333 Figure 3 1 Schematic diagram of the Parallel Redundancy Protocol With the Parallel Redundancy Protocol PRP each node must transmit Ethernet frames on two independent parallel networks These are two physically separate networks with a bus linear star or ring topology The PRP destination device must also be connected to the two networks This then receives each frame twice The first frame is forwarded to the application The second frame received is recognized and discarded This achieves N 1 redundancy without reconfiguration bumpless switchover There are already end devices equipped with two Ethernet interfaces that are capable of handling the Parallel Redundancy Protocol Double Attached Nodes PRP DANP On the other hand there are many end devices starting with S7 controllers right thr
73. mbers System manual Industrial Ethernet Network Manual Order number 6GK1970 1BA10 OAAO Only available here http support automation siemens co m WWiview en 27069465 Available for SCALANCE All IE FC Stripping Tool 6GK1901 1GA00 All IE FC blade cassettes 6GK1901 1GB00 All IE FC TP standard cable GP 6XV1840 2AH10 All IE FC TP trailing cable 6XV1840 3AH10 All IE FC TP marine cable 6XV1840 4AH10 All IE FC TP trailing cable GP 6XV1870 2D All IE FC TP flexible cable GP 6XV1870 2B All IE FC FRNC cable GP 6XV1871 2F All IE FC TP festoon cable GP 6XV1871 2S All IE FC TP food cable 6XV1871 2L All IE TP torsion cable 6XV1870 2F All Energy cable 2 x 0 75 6XV1812 8A All IE FC RJ 45 Plug 180 pack of 1 6GK1901 1BB10 2AA0 All IE FC RJ 45 Plug 180 pack of 10 6GK1901 1BB10 2ABO All IE FC RJ 45 Plug 180 pack of 50 6GK1901 1BB10 2AE0 All IE FC outlet RJ 45 6GK1901 1FCO0 OAAO All TP cord RJ 45 RJ 45 0 5m 6XV1870 3QE30 All 1 0m 6XV1870 3QH10 All 2 0m 6XV1870 3QH20 All 6 0 m 6XV1870 3QH60 All 10m 6XV1870 3QN10 All SFP module SFP991 1 multimode glass up to 3 km 6GK5991 1AD00 8AA0 SCALANCE X204RNA EEC SFP991 1LD monomode glass up to 26 km 6GK5991 1AF00 8AAO SCALANCE X204RNA EEC SFP991 1LH monomode glass up to 70 km 6GK5991 1AE00 8AA0 SCALANCE X204RNA EEC Glass fibers MM robust cable 50 125 900 um 6XV1873 2R
74. n as well as by mechanical bending The amount of attenuation depends among other things on the wavelength of the input light The single mode fiber typically has a core diameter of 5 to 9 um The outer diameter is however once again 125 um compare multimode The smaller core diameter degrades the pulse edges less than multimode transmission and allows greater transmission distances Simple Network Management Protocol Standardized protocol for transporting network management information Simple Network Time Protocol Protocol for time synchronization over networks Secure Shell This allows an interactive connection to be established to another device in the LAN or on the Internet Otherwise the functionality corresponds to that of Telnet Secure Socket Layer This protocol allows encrypted exchange of data with a server There is also secure authentication of the server For communication with a server over SSL the server must have a certificate and a corresponding private key Store and forward TELNET TFTP An entire frame is received its validity checked checksum length etc and then buffered Invalid frames are discarded in other words a frame is forwarded only when it is error free With this protocol an interactive connection can be established to another device in the LAN or on the Internet The user then has the same options as when directly connected to this device with a terminal Trivial File Transfer Proto
75. n automatic logout after the 15 minutes or after the time configured in the Agent Timeout Configuration menu A manual logout is also possible with the appropriate button in the user interface Exiting the browser does does not close the session If the browser is started again within the timeout the session continues to be used Note To use SNMP Management RMON and traps you require a network management station This does not ship with IE switches SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 43 Functional description and configuration using Web based Management 7 2 Prerequisite 7 2 Prerequisite Note The screens described in this section apply to the SCALANCE X200RNA devices The screens of the SCALANCE X204RNA EEC were chosen to illustrate the examples Any significant deviations from the screens of the SCALANCE X204RNA are pointed out or shown Principle of Web Based Management The SCALANCE X200RNA devices have an integrated HTTP server for Web Based Management If a SCALANCE X 200RNA is addressed using a Web browser it returns HTML pages to the client computer depending on the user input The user enters the configuration data in the HTML pages sent by the SCALANCE X 200RNA A SCALANCE X 200RNA evaluates this information and generates reply pages dynamically The great advantage of this method is that apart from a Web browser no special software is required on the client
76. n the core Attenuation is mainly caused by physical absorption and dispersion as well as by mechanical bending The amount of attenuation depends among other things on the wavelength of the input light Multimode fiber optic cables have an outer diameter of 125 um and 50 or 62 5 um core diameter Due to the larger core diameter the pulse edges degrade more than in single mode transmission resulting in shorter transmission distances PRP is a redundancy protocol for Ethernet networks It is defined in the standard IEC 62439 Industrial Communication Networks High Availability Automation Networks in Part 3 Parallel Redundancy Protocol PRP and High availability Seamless Redundancy HSR With PRP frames are exchanged at the same time via a two separate Ethernet networks If a transmission path is interrupted the frame arrives at its destination via the second path This is bumpless without reconfiguration times to find new paths Remote Monitoring RMON compliant devices allow diagnostic data to be collected on the device and read out by a network management station This means that network problems are detected early and can be eliminated The particular advantage of RMON is that it is independent of location The acquired data can be analyzed at any point in the network with suitable reporting software SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 115 Glossary RNA RSTP Secure Shell Redundant network ac
77. ns Functional description and configuration using Web based Management 7 7 The Agent menu 7 7 6 Agent Syslog Configuration Setting the timeout Here you can set the times after which there is an automatic logout in WBM SIEMENS Automation amp Drives Console Support Logout Power CPU Status Status Status Status SIMATIC NET Wo SIMATIC NET Industrial Ethernet ees SCALANCE X204RNA EEC PAO Pe OPi OP2 E 192 168 1 1 X204 RNA EEC Agent Syslog Configuration 17 System H x200 Syslog Server IP Address 192 168 1 113 I Agent 11 SNMP El Timeout Config El Event Config Syslog Config Time Config 17 Switch Syslog Server Port 514 Refresh Set Values Figure 7 23 Agent Syslog Configuration Syslog Server IP Address Enter the IP address of the Syslog server Syslog Server Port Enter the port of the Syslog server SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 75 Functional description and configuration using Web based Management 7 7 The Agent menu 7 7 7 Agent Time Configuration Time of day synchronization in the network SNTP Simple Network Time Protocol is used for synchronizing the time in the network The appropriate frames are sent by an SNTP server in the network A SCALANCE X 200RNA logs on as client with this server as recipient of time of day frames SIEMENS automation amp Drives Console Support e Logout SI
78. nts SCALANCE X204RNA 17 SCALANCE X204RNA EEC 21 R Redundancy error 30 Refresh 52 Restart 56 S Safety notices 9 Set Value 52 119 Index SNMP 72 SNMP trap 73 Statistics 85 Subnet mask 70 Switch Switch Forwarding Database 84 Syslog 71 78 T Time of day SNTP Simple Network Time Protocol 79 Time zone 80 Time of day synchronization 79 UTC time 80 Time zone 80 U UL approval 8 to UL 508 96 to UL 60950 96 UTC time 80 W Web Based Management 48 120 SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions
79. on amp Drives Console e Support e Logout SIMATIC NET CPU Status Status Status Status SIMATIC NET Industrial Ethernet SCALANCE X204RNA EEC PA O P8 OPI MP2 o 192 168 1 1 J X204 RNA EEC Packet Error Statistic System ae Port Bad Frames CRC Undersize Oversize Dropped L2 2200 A 0 0 0 0 0 13 Agent B 0 0 0 0 0 i 0 0 0 0 0 a z 0 0 0 0 0 Ports E FDB Y Statistics Packet Size Packet Type B Packet Error PRP Refresh Reset Counters Figure 7 32 Packet Error Statistic If you click on an entry in the Port column the Packet Error Statistics graphic is displayed for the selected port You then see a configurable graphical representation of the counter value Graphic representation of the statistics This page displays the number of bad frames graphically The display is dependent on the cause of the error There is a separate element in the graphic for each of the following causes of error e Bad Frames e CRC e Undersize SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 87 Functional description and configuration using Web based Management 7 8 The Switch menu e Oversize e Dropped L2 SIEMENS Automation amp Drives Console e Support e Logout SIMATIC NET CPU Status Status Status Status SIMATIC NET Industrial Ethernet SCALANCE X204RNA EEC PA O P8 O Pi B P2 o 192 168 1 1 X204 RNA EEC Packet Error Statistic Graphic System 3 x200 Agent
80. on the configuration data can only be read via DCP PST Tool and STEP 7 Default gateway If you require the IE switch to communicate with devices diagnostics stations e mail servers etc in a different subnet you will need to enter the IP address of the default gateway here SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions Functional description and configuration using Web based Management 7 7 The Agent menu MAC address The MAC address of the SCALANCE X 200RNA 7 7 2 Agent SNMP Configuration How SNMP works Using SNMP Simple Network Management Protocol a Network Management Station can configure and monitor SNMP compliant nodes such as a SCALANCE X 200RNA To allow this a management agent is installed on the SCALANCE X 200RNA with which the management station exchanges data There are three frame types e Read management station fetches values from a SCALANCE X 200RNA e Write management station writes values to a SCALANCE X 200RNA e Send events to registered nodes traps The agent sends messages to registered management stations Configuration of SNMP with a SCALANCE X 200RNA The Agent SNMP Configuration screen appears if you click the SNMP folder icon In the SNMP Configuration screen you make the basic settings for SNMP Enable the check boxes according to the SNMP functionality you want to use For detailed settings for example traps there are separate menu items in WBM SCALANC
81. onal description and configuration using Web based Management 7 8 The Switch menu SIEMENS Automation amp Drives Console Support Logout SIMATIC NET CPU Status Status Status Status SIMATIC NET Industrial Ethernet SCALANCE X204RNA EEC PA O P8 O PI B P2 O 192 168 1 1 ka X204 RNA EEC Packet Size Statistic 1 System e Port 64 65 127 128 255 256 511 512 1023 1024 1536 a X200 A 1475 5 0 0 0 0 1 Agent B 1475 5 0 0 0 0 F i 2653 66 6 1201 1279 1250 ka 2 5 0 0 0 0 0 E Ports E FDB Y Statistics B Packet Size Packet Type E Packet Error PRP Refresh Reset Counters Figure 7 28 Packet Size Statistic If you click on an entry in the Port column the Packet Size Statistics graphic is displayed for the selected port You then see a configurable graphical representation of the counter value Graphic representation of the statistics This page displays the number of frames received at each port graphically The display is dependent on the frame length There is a separate element in the graphic for each of the following ranges e 64 bytes e 65 127 bytes e 128 255 bytes e 256 511 bytes SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 83 Functional description and configuration using Web based Management 7 8 The Switch menu e 512 1023 bytes e 1024 1536 bytes SIEMENS Automation amp Drives Console Support e Logout SIMATIC NE
82. operated SIEMENS astome on Dres Console Support Logout SIMATIC NET 5 CPU Status Status Status Status SIMATIC NET Industrial Ethernet B SCALANCE X204RNA EEC PA D Pe DPI O P2 o 192 168 1 1 E x204 RNA EEC System Version Numbers 3 System 5 isu Hardware Restart amp Defaults FPGA Version E Save amp Load HTTP Firmware B Version Numbers FW Build Sep 21 2011 17 13 55 E Passwords Order Number 3 Select Set Button Event Log 53 x200 Agent Y Switch Figure 7 8 System Version Numbers Hardware The version of the firmware is shown here The hardware version product version it is stored permanently on the SCALANCE X 200RNA FPGA Version The FPGA version is shown here Firmware The version of the firmware running on the SCALANCE X 200RNA FW Build The date on which the firmware running on the SCALANCE X 200RNA was created is displayed here SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 55 Functional description and configuration using Web based Management 7 5 The System menu 7 5 6 System Passwords System passwords Note Default for the passwords when supplied Admin password admin User password user In this dialog if you are the administrator you can change the passwords for Admin and User The password can be up to a maximum of 16 characters 7 bit ASCII long SIEMENS Automation amp Drives Console 4 Support Logout SIMATIC NET
83. ots for SFP modules The SFP modules can be used as an alternative to the two RJ 45 jacks PRP A and PRP B and are intended for the connection of the LAN A and LAN B networks End devices or network segments without PRP capability are connected to the RJ 45 jacks P1 and P2 i e Figure 4 3 SCALANCE X204RNA EEC SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 21 Product characteristics 4 5 SCALANCE X204RNA EEC 4 5 2 SCALANCE X204RNA EEC TP interfaces SCALANCE X204RNA EEC TP interfaces Connector pinout On the SCALANCE X204RNA EEC the TP interfaces are implemented as RJ 45 jacks with the MDI X assignment Medium Dependent Interface Autocrossover of a network component 8 7 6 5 4 3 2 1 Figure 4 4 RJ 45 jack Table 4 4 Pin assignment Pin number Assignment Pin 8 n C Pin 7 n C Pin 6 TD Pin 5 n C Pin 4 n C Pin 3 TD Pin 2 RD Pin 1 RD NOTICE TP cords or TP XP cords with a maximum length of 10 m can be connected to the RJ 45 TP port With the IE FC cables and IE FC RJ 45 plug 180 an overall cable length of up to 100 m is permitted between two devices depending on the cable type Note The interfaces of the SCALANCE X204RNA EEC meet the requirements for environment B according to IEEE 802 3 section 33 4 1 1 SCALANCE X204RNA SCALANCE X204RNA EEC 22 Operating Instructions Product characteristics 4 58 SC
84. ough to control computers that communicate using TCP IP but do not support PRP and some even have only one Ethernet Interface With all these devices a SCALANCE X 200RNA can be connected upstream from them This allows access for Single Attached Nodes SAN to PRP networks Industrial Ethernet bus linear star or ring structures with switching functionality can be implemented cost effectively with devices of the SCALANCE X product line You will find a list of usable network components in Table 10 2 Compatible SCALANCE X devices oversized frames 1532 bytes Page 103 SCALANCE X204RNA SCALANCE X204RNA EEC 14 Operating Instructions Product characteristics 4 1 Overview of the product characteristics Overview of the product characteristics The SCALANCE X204RNA and the SCALANCE X204RNA EEC have the same functionality and differ only in the environmental conditions the input voltage ranges and the option of using SFP modules with the SCALANCE X204RNA EEC Table 4 1 Overview of the product characteristics SIMATIC environment Device type SCALANCE X204RNA X204RNA EEC Diagnostics LED 24 VDC 24 V 250 VDC 100 V 240 VAC Housing Plastic 2 x 24 VDC 100 Base T full duplex half duplex e 10 Base T Signaling contact on site operation set reset button Diagnostics Web SNMP C PLUG not supported in implementation stage 1 IRT capability S
85. own Restart amp Defaults 02 47 21 075 2011 10 24 04 46 58 m DIAG 2 ON P1 Link down B Save amp Load HTTP 02 47 21 075 2011 10 24 04 46 58 m DIAG 0 ON PRP_A Link down e aS 00 00 03 708 DIAG31 OFF Startup in progress Version Numbers 00 00 00 246 Reinitialization of SNMP agent El Passwords 00 00 00 162 DIAG10 ON PRP fault receiving ID Avia PRP_B Select Set Button El Event Log 3 x200 17 Agent 1 Switch BEntries Figure 7 11 System Event Log Table The Restart column indicates the device restart after which the corresponding event occurred The Sys Up Time column shows the time since the SCALANCE X 200RNA was last restarted in the format HH MM SS Refresh Click on this button to refresh the display SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions Functional description and configuration using Web based Management 7 5 The System menu Clear With this button you can delete the content of the log table SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 59 Functional description and configuration using Web based Management 7 6 The X200 menu 7 6 The X200 menu 7 6 1 X200 Status Information on the operating status This screen appears if you click the X200 folder icon The screen shows information about the power supply and the error status SIEMENS Automation amp Drives Console e Support e Logout Power CPU Status Status Status Status
86. perating Instructions Product characteristics 4 4 SCALANCE X204RNA 4 4 2 SCALANCE X204RNA TP interfaces SCALANCE X204RNA TP interfaces Connector pinout On the SCALANCE X204RNA the TP interfaces are implemented as RJ 45 jacks with the MDI X assignment Medium Dependent Interface Autocrossover of a network component 8 F 6 5 4 3 2 1 Figure 4 2 RJ 45 jack Table 4 3 Pin assignment Pin number Assignment Pin 8 n C Pin 7 n C Pin 6 TD Pin 5 n C Pin 4 n C Pin 3 TD Pin 2 RD Pin 1 RD NOTICE TP cords or TP XP cords with a maximum length of 10 m can be connected to the RJ 45 TP port With the IE FC cables and IE FC RJ 45 plug 180 an overall cable length of up to 100 m is permitted between two devices depending on the cable type Note The interfaces of the SCALANCE X204RNA meet the requirements for environment B according to IEEE 802 3 section 33 4 1 1 SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 19 Product characteristics 4 4 SCALANCE X204RNA Autonegotiation Autonegotiation means the automatic detection of the functionality of the port at the opposite end Using autonegotiation repeaters or end devices can detect the functionality available at the port of a partner device allowing automatic configuration of different types of device With autonegotiation two components connected to a link segment can exc
87. r Power CPU Status Status Status Status SNMPv1 Trap Configuration Figure 7 19 SNMPv1 Trap Configuration IP Address IP Address E j Automation amp Drives SIMATIC NET Industrial Ethernet Enable Trap SCALANCE X204RNA EEC 192 168 1 1 Here you enter the addresses of the stations to which a SCALANCE X 200RNA will send traps Enable Trap Click on the check box next to the IP addresses to enable the sending of traps to the corresponding stations SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 71 Functional description and configuration using Web based Management 7 7 The Agent menu 7 7 4 Agent Timeout Configuration Setting the timeout Here you can set the times after which there is an automatic logout in WBM SIEMENS Automation amp Drives Power CPU Status Status Status Status SIMATIC NET Industrial Ett t SCALANCE X204RNA EEC 192 168 1 1 Agent Timeout Configuration Figure 7 20 Agent Timeout Configuration Web Based Management sec Here you specify the WBM timeout Permitted values for the WBM timeout 60 3600 seconds 0 means There is no automatic logout SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 72 Functional description and configuration using Web based Management 7 7 The Agent menu 7 7 5 Agent Event Configuration System events of the SCALANCE X 200RNA On this page you specify how a SCALANCE X 20
88. rances there is then an adequate stream of air for heat dissipation during operation Keep to the following minimum clearances to neighboring devices Minimum clearances for installation in control cabinets Minimum clearance to devices below the switch Minimum clearance to devices above the switch Minimum clearance at the sides X204RNA EEC SCALANCE X204RNA SCALANCE X204RNA EEC 32 Operating Instructions Installation 5 2 Din rail mounting 5 2 Din rail mounting Installation Install the SCALANCE X 200RNA on a 35 mm DIN rail complying with DIN EN 60715 1 Place the upper catch of the device over the top of the DIN rail and then push in the lower part of the device against the rail until it clips into place 2 Fit the connectors for the power supply 3 Fit the connectors for the signaling contact 4 Insert the terminal blocks into the sockets on the device Figure 5 1 Mounting on the DIN rail based on the example of a SCALANCE X204RNA EEC SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 33 Installation 5 2 Din rail mounting Fitting the protective bracket O Hang onto rail at top O Lock in position below Secure with the screw Figure 5 2 Mounting the protective bracket on the SCALANCE X204RNA EEC SCALANCE X204RNA SCALANCE X204RNA EEC 34 Operating Instructions Installation 5 2 Din rail mounting Uninstalling Removing a SCALANCE X 200RNA from a DIN rail 1 First d
89. reset the counters for all ports SIEMENS Automation amp Drives Console Support Logout SIMATIC NET CPU Status Status Status Status SIMATIC NET Industrial Ethernet SCALANCE X204RNA EEC PA O P8 O Pi MP2 O 192 168 1 1 ES X204 RNA EEC PRP Statistic Received A Frames at PRP A Port o SS Statistics Received B Frames at PRP B Port o El Packet Size Received B Frames at PRP A Port 0 Packet Type Received A Frames at PRP B Port o E Packet Error B pre Refresh Reset Counters Figure 7 34 PRP Statistic SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 89 Approvals and marking 8 8 1 Approvals and marking Approvals and marking Product name EC directives Note The specified approvals apply only when the corresponding mark is printed on the product You can check which of the following approvals have been granted for your product by the markings on the type plate Type designation Order number SCALANCE X204RNA 6GK5204 0BA00 2KB2 SCALANCE X204RNA EEC 6GK5204 0BS00 3LA3 SIMATIC NET products meet the requirements and aims of the following EC directives Conformity certificates You will find the EC Declaration of Conformity for this product on the Internet at the following address http support automation siemens com WW view de 523237 14 133400 gt Entry list gt Entry type Certificates gt Type of certificate Declaration
90. rotection n e and EN 60079 0 FM approval The SCALANCE X204RNA meets the requirements of the standards e Factory Mutual Approval Standard Class Number 3611 e FM Hazardous Classified Location Electrical Equipment Non Incendive Class Division 2 Groups A B C D T4 A and Non Incendive Class Zone 2 Group IIC T4 FDA and IEC approvals The following products meet the FDA and IEC requirements listed below e SFP module SFP991 1LD e SFP module SFP991 1LH FDA swith 21 CFR 1040 10 and 1040 11 Figure 8 1 FDA and IEC approvals Notice for Australia C Tick The product meets the requirements of the AS NZS 2064 standard Class A SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 93 Approvals and marking 8 1 Approvals and marking Notice for Korea Kc The product meets the requirements of the Korea Certification UL Approval for Information Technology Equipment Underwriters Laboratories UL complying with Standard UL 60950 1 UL Approval for Industrial Control Equipment Underwriters Laboratories UL complying with Standard UL 508 CSA Approval for Information Technology Equipment CSA Certification Mark Canadian Standard Association CSA C22 2 No 60950 1 03 CSA Approval for Industrial Control Equipment CSA Certification Mark Canadian Standard Association CSA C22 2 No 142 M1987 cULus Approval for Information Technology Equipment Underwriters Laboratories Inc complying with e UL
91. s 4 2 Components of the product 4 2 Components of the product SCALANCE X204RNA The following components are supplied with the SCALANCE X204RNA e SCALANCE X204RNA device e 2 pin plug in terminal block signaling contact e 4 pin plug in terminal block redundant power supply e User Manual Compact BAK e CD Operating Instructions PST Tool SCALANCE X204RNA EEC The following components are supplied with the SCALANCE X204RNA EEC e SCALANCE X204RNA EEC device e 3 pin plug in terminal block signaling contact e 3 pin plug in terminal block power supply e User Manual Compact BAK e CD Operating Instructions PST Tool e Bracket for guiding the cable mechanical protection 4 3 Unpacking and checking Unpacking checking 1 Make sure that the package is complete 2 Check all the parts for transport damage A WARNING Do not use any parts that show evidence of damage SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 17 Product characteristics 4 4 SCALANCE X204RNA 4 4 SCALANCE X204RNA 4 4 1 SCALANCE X204RNA product characteristics SCALANCE X204RNA product characteristics Possible attachments The SCALANCE X204RNA has two RJ 45 jacks for connection of end devices or network segments not capable of PRP P1 and P2 and two RJ 45 jacks for connecting the PRP networks LAN A and LAN B PRP A and PRP B Figure 4 1 SCALANCE X204RNA SCALANCE X204RNA SCALANCE X204RNA EEC 18 O
92. s for their own purposes could violate the rights of the owner Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described Since variance cannot be precluded entirely we cannot guarantee full consistency However the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions Siemens AG Copyright Siemens AG Industry Sector 02 2012 Technical data subject to change All rights reserved Postfach 48 48 90026 NURNBERG GERMANY Table of contents 1 Introduction ta A TT 7 1 1 Introducti 23400 ici AA eae eel At A ti 7 2 Safety NOS iii A AA ety An tii 9 2 1 Safety NOUCES 2 5 shia a ate AA eee 9 3 Network topologies and reduUNndaNCy ccoooccccnnnnccccnnnoccconnnnnccnnnnnncc cnn nan nc nana 13 3 1 Network topology and redundancy oooccccococccccononccinanonnnccannnnccnnnn cnc cnn nn nn nc nano nn cc naar nn cc naar nnncnnnnanccins 13 4 Product characteristics oh acai tie dete ra ites ade 15 4 1 Overview of the product characteristics cccccceeeeeeeeeeececeeeeeeeeeeaeeeeeeeeeseceneaeceeeeeeeeeesncaeeneees 15 4 2 Components of the product a cecduaaanceeacedaceaadandacdecseceudusesncedecesacuaqiaadaclecgeaes 17 4 3 Unpacking and CheckiNQ oooooonoccccnnnocccccnononcccnononcncnanoncncnnno nc i canon cnc naar nn cc cnn nc AN AE a cnn N 17 4 4 SCALANCE X204 RNA ro es y dee te li db 1
93. tructions Dimension drawings 12 1 Dimension drawings ot SCALANCE SIEMENS X204RNA EEC 29 PF For LAN only LAN NV AN Figure 12 3 SCALANCE X204RNA EEC front view SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 111 sion 12 1 Dimension drawings 0000001 D000000 10000000 10000000 10000000 000000 ooon J000000 10000 10000 pro il i JUUUUUUL JUUUU il 0000000000000 f 0000000000000 Glossary Aging time Autocrossover Autonegotiation CLI C PLUG CRC DCP Default gateway The aging time is the time after which a learned address is discarded if a SCALANCE X 200RNA has not received frames with this sender address during this time Technique with which a TP port is automatically switched over between MDI and MDI X assignment to make a connection independent of the port assignment of the device being attached This means that crossover cables are not required The autocrossover function can only be used when the port is set to autonegotiation mode Procedure standardized by IEEE 802 3 in which the transmission parameters for example 10 100 Mbps full half duplex are negotiated automatically between the devices Command Line Interface Terminal based configuration option for SCALANCE The CLI can be used via an Ethernet connection The C
94. ust meet NEC Class 2 as described by the National Electrical Code r ANSI NFPA 70 The power of all connected power supply units must total the equivalent of a power source with limited power LPS limited power source If the device is connected to a redundant power supply two separate power supplies both must meet these requirements The signaling contact can be subjected to a maximum load of 100 mA safety extra low voltage SELV 24 VDC Never operate the SCALANCE X204RNA with AC voltage or DC voltage higher than 28 8 V DC 24 VDC power supply CAUTION If the SCALANCE X204RNA is supplied over long 24 V power supply lines or networks measures are necessary to prevent interference by strong electromagnetic pulses on the supply lines These can result for example due to lightning or switching of large inductive loads One of the tests used to attest the immunity of the SCALANCE X204RNA to electromagnetic interference is the surge immunity test according to EN61000 4 5 This test requires overvoltage protection for the power supply lines A suitable device is for example the Dehn Blitzductor VT AD 24 V type no 918 402 or comparable protective element Vendor DEHN S HNE GmbH Co KG Hans Dehn Str 1 Postfach 1640 D 92306 Neumarkt Germany SCALANCE X204RNA SCALANCE X204RNA EEC 38 Operating Instructions Connection 6 1 Power supply Power supply 100 240 VAC 24 250 VDC AR W
95. ved frames with the corresponding sender address Here the aging time can be set as required within the range from 0 to 655 seconds 7 8 3 Port status Overview of the configuration of the ports The Port Status screen appears if you click the Ports folder icon The screen shows the configuration for data transfer for all ports of the SCALANCE X 200RNA SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions 79 Functional description and configuration using Web based Management 7 8 The Switch menu 80 SIEMENS Automation amp Drives Console Support e Logout SIMATIC NET S roe p ates Seats State Set SIMATIC NET Industrial Ethernet K SCALANCE X204RNA EEC PA O PB OPI P2 oO 192 168 1 1 EJ x204 RNA EEC System Port Type Negotiation Active Link A TP 100 TX enabled true down Agent B TP 100TX enabled true down 523 Switch 1 TP 100TX enabled true up 2 TP 100 TX enabled true down Ports FDB 2 Statistics Figure 7 26 Port status The five columns of the table display the following information Port This shows the port with the SCALANCE X204RNA also the SFP slot to which the following information relates Type Displays the type of port This information is important because difference modules and therefore different ports can be used in some slots The following port types are possible e TP 100 TX e FO 100 FX Negotiation Indicates whether or not autonegotiation is ena
96. y notices A WARNING Opening the device WARNING EXPLOSION HAZARD DO NOT OPEN WHEN ENERGIZED General notices on use in hazardous areas A WARNING Risk of explosion when connecting or disconnecting the device WARNING EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR COMBUSTIBLE ATMOSPHERE IS PRESENT A WARNING Replacing components WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I DIVISION 2 OR ZONE 2 A WARNING Requirements for the cabinet enclosure When used in hazardous environments corresponding to Class l Division 2 or Class Zone 2 the device must be installed in a cabinet or a suitable enclosure General notices on use in hazardous areas according to ATEX SCALANCE X204RNA only 10 A WARNING Requirements for the cabinet enclosure To comply with EC Directive 94 9 ATEX95 this enclosure must meet the requirements of at least IP54 in compliance with EN 60529 A WARNING Suitable cables for temperatures in excess of 70 C If the cable or conduit entry point exceeds 70 C or the branching point of conductors exceeds 80 C special precautions must be taken SCALANCE X204RNA SCALANCE X204RNA EEC Operating Instructions Safety notes 2 1 Safety notices WARNING Protection against transient voltage surges Take measures to pr
97. you can see the individual parameters for Identification 84 Maintenance SCALANCE X204RNA SCALANCE X204RNA EEC 50 Operating Instructions Functional description and configuration using Web based Management 7 5 The System menu 7 5 3 System Restart amp Defaults Resetting the settings In this menu you will find a button for restarting the SCALANCE X 200RNA as well as options for resetting the settings of the SCALANCE X 200RNA SIEMENS Automation amp Drives Console Support e Logout SIMATIC NET i CPU Status Status Status Status SIMATIC NET Industrial Ethernet SCALANCE X204RNA EEC PA O P8 OPI O P2 oO 192 168 1 1 E X204 RNA EEC System Restart and Defaults J System 18M B Restart amp Defaults Restart System Save amp Load HTTP Passwords Select Set Button Event Log x200 Agent switch Figure 7 6 System Restart and Defaults Note Note the following points about restarting a SCALANCE X200RNA e You can only restart the SCALANCE X 200RNA with administrator privileges e A SCALANCE X 200RNA should only be restarted with the buttons of this menu and not by a power cycle on the device e The browser must not be set so that it reloads the page from the server each time the page is accessed The updating of the dynamic content of the page is ensured by other mechanisms In the Internet Explorer you can make the appropriate setting in the Options gt Internet Options gt