Home

iFan intelligent silent office extractor fan user manual here

image

Contents

1. ACCEPTANCE CERTIFICATE q INTELLIGENT AXIAL FAN ff _ user s manual The fan is duly recognized Approval mark intelligent fan If ad zx F as serviceable Manufactured on date model VENTS iFon TAE and stamp of the trade company VO1EN iFan 02 Y VENTS 2012 www ventilation system com Thank you for purchasing the fan made by VENTS iFan is an innovative extract bathroom fan enclosed into a compact casing The unique technologies combined with smart electronics support the ideal comfort and microclimate in your house The stylish fan design matches well with any modern interior We do hope that you are happy with your fan s quality of performance N WARNING Disconnect the fan from power mains prior to any connection servicing and repair operations Mounting and maintenance are allowed for duly qualified electricians with valid electrical work permit for electric operations at the units up to 1000 V after careful study of the present user s manual The single phase power grid must comply with the acting local electrical norms and standards The fixed electrical wiring must be equipped with an automatic circuit breaker The fan must be connected to power mains through an automatic circuit breaker integrated into the fixed wiring system with the gap between the breaker contacts on all poles not less than 3 mm Check the fan for any visible damages of the impelle
2. Fan operation in 4 Signal to LI terminal light is on mode is activated Silent mode y Humidity Switch Motion z Signal to LI terminal stabilization is off if off light is off y Y m Humidity extraction a Turn on delay KJ timer starts timer starts 30 45 60 min 5 15 30 min Gtan intelligent fan Wiring diagram 4 L and N terminals are connected to live and neutral respectively LT terminal is connected to live through the external momentary switch that is activated by opening a door The fan is in standby mode and does not run As 24 HOURS Mode is activated the fan runs permanently at low speed to ensure minimum round the clock ventilation As the external momentary switch is closed the fan switches to SILENT mode for the period adjusted in the off delay timer After that the fan reverts to standby mode As motion sensor is activated for iFan Move only the fan switches to SILENT mode After no motion is detected the fan reverts to standby mode As humidity level increases the fan switches to MAX mode by default or to SILENT mode After humidity level drops the fan reverts to standby mode eZ Standby mode fan does not run or 24 Hours mode Fan operates at 40 33 m h External switchi is activated Motion sensor is activated Humidi
3. timer starts 0 2 5 min MAX SILENT Motion sensor is activated Turn on delay timer starts 0 2 5 min Vv Signal to LI terminal light is on e _ _____ Vv ee ye 9 mode is activated Humidity stabilization Humidity extraction timer starts 30 45 60 min Fan operation in Silent mode ae Vv Motion if off Vv x Signal to LI terminal light is off Turn on delay timer starts 5 15 30 min Gan intelligent fan Wiring diagram 2 L and N terminals are connected to live and neutral respectively and L and LT terminals are joined by the jumper The fan is always in SILENT mode 24 Hours mode may not be activated No matter of the signal from the motion sensor the fan operated in SILENT mode As humidity level increases the fan switches to MAX mode by default or continues operation in SILENT mode if adjusted by the user After humidity level drops to standard level the fan reverts to SILENT mode ae gt C Fan operates at 83 72 m h MAX 40 33 m h MAX Humidity change a Turn on delay J timer starts Motion sensor is activated J Sane a Turn on delay timer starts 0 2 5 min 0 2 5 min y v Qs a MAX SILENT a
4. Fan operation in mode is activated Silent mode y Humidity stabilization Ei Motion if off Humidity extraction timer starts 30 45 60 min Q Turn on delay timer starts 5 15 30 min x inteligent fan Signal to LI terminal light is on Signal to LI terminal light is off Wiring diagram 3 Land N terminals are connected to live and neutral respectively LT contact is connected to live through external switch light switch The fan is always in standby mode As 24 HOURS Mode is activated the fan runs permanently at low speed to ensure minimum round the clock ventilation As the external switch is closed the fan switches to SILENT mode After the external switch is off the fan reverts to standby mode As motion sensor is activated for iFan Move only the fan switches to SILENT mode After no motion is detected the fan reverts to standby mode As humidity level increases the fan switches to MAX mode by default or to SILENT mode After humidity level drops the fan reverts to standby mode Standby mode fan does not run or 24 Hours mode Fan operates at 40 33 m h Switch is closed Humidity change Tj Motion sensor is activated Turn on delay timer starts 0 2 5 min 0 2 5 Turn on delay timer starts min j MAX SILENT
5. indicator STATUS is green The fan is in standby mode the light indicator STATUS blinks green once in 2 seconds on Fan operation in 24 Hours mode the light indicator is red Fan operation in humidity extraction mode the light indicator STATUS blinks red once in 2 seconds X Fan operation in interval ventilation mode the light indicator STATUS blinks in turn red and green once in i in turn on delay mode the light indicator STATUS blinks red twice in 1 second x Gian intelligent fan SILENT MODE SPEED ADJUSTMENT By default the speed is 83 72 m h To adjust the speed press the buttons or Press the button or to display the current air capacity MAX MODE SPEED ADJUSTMENT By default the speed is 97 82 m h To adjust this speed press the button MODE hold it and adjust the required speed with buttons or Press the button or together with the button MODE once to display the current air capacity Number of active Air capacity light indicators m h 1 40 33 48 41 A4 525 5 57 49 67 57 72 61 77 66 F S 9 10 Number of active light indicators 83 72 Air capacity m h 83 72 87 75 92 79 97 82 103 86 o peN 109 90 gt tog a 121 98 10 133 106 HUMIDITY EXTRACTION MODE SELECTION By default the extraction mode is MAX mode When humidity level inc
6. persons with respect to the product in case of force majeure fire flood earthquake war hostilities of any kind blockade in case of absent seals provided such seals are prescribed by the User Manual or other relevant substituting document in case of unavailable warranty card in case of unavailable payment document to confirm the purchase with indication of the sale date The manufacturing company shall be responsible for defects arising through its fault prior to the moment of transferring the product to the ownership of the customer The manufacturing company shall not be responsible for defects arising after transferring the product to the customer and caused by the customer s violating the rules of transportation storage assembly and operation of the product or by actions of third persons an accident or force majeure circumstances The manufacturing company shall not be responsible for damage to health and property of the customer caused by the customer s violating the User Manual or other relevant substituting document other use of the product by the customer other than its intended use or by failure of the Customer to comply with warnings and other information on the product specified in the User Manual or other relevant substituting document or by the customer s violating the rules of transportation storage mounting maintenance and operation of the product Gian intelligent fan
7. andby mode standard operation mode for the fan in case of no signalling from the sensors or external switch In standby mode the fan does not run 2 24 Hours the fan runs at low speed for minimum round the clock ventilation As humidity level increases the fan switches to MAX mode by default or to SILENT mode The fan switches to SILENT mode when the motion sensor is activated or 100 125 iFan 72 iFan Move 24 Hours Silent 83 40 83 Max 133 83 133 Table 3 Functions Model Humidity 24H Turn on Off delay Speed Interval External Motion control oN delay timer timer control ventilation switch sensor iFan iFan Move 3 SILENT silent operation mode of the fan This mode is may be activated by the motion sensor external switch or humidity sensor For humidity sensor this mode may be activated from the fan 4 MAX humidity activated operation mode It is switched on as humidity level increases This mode is activated for the humidity sensor by default intelligent fan PRODUCT MOUNTING The fan is designed for mounting into round 100 or 125 mm air duct or installation into the ventilation shaft The replaceable adapter of required size may be used to facilitate mounting The fan is equipped with a removable grille Press the latches slightly to release the grille from the front cover While installing the grille on the front cover back match th
8. cluding any components disassembled by the customer in case of incompliance of the model or marking of the product with data specified on the product packaging and in the User Manual or other relevant substituting document in case of non timely technical maintenance of the product by the customer dust mud oil condensate foreign particles in case of causing external damage to the product by the customer damage shall not apply to external changes of the product tam in case of altering the product design or further reworking of the product fol taR in case of replacing and using parts units and components of the product not prescribed by the manufacturing company in case of other use of the product other than intended use in case of the customer s violating product operation rules in case of connecting the product to electric mains of voltage exceeding voltage value specified in the User Manual in case of step voltage that resulted in the product failure in case of the customer s performing unauthorised repair of the product in case of performing repair of the product by third persons unauthorized by the manufacturing company in case of warranty period service life expiry in case of the customer s violating transportation rules assuring prevention of damaging and or destruction of the product in case of the customer s violating product storage rules in case of performing unlawful actions by third
9. e latches and respective slots in the cover and insert to click The pointer on the reverse side of the grille must be directed to the shorter side close to the hole Gtan intelligent fan The fan casing has three round lowered tabs for cable entry Cut out a hole at the most suitable place with a knife FAN MOUNTING SEQUENCE intelligent fan The fan may be connected to power mains by four wiring diagrams The fan is compatible with 100 240 V 50 60 Hz power mains The iFan Move has LI terminal for connection to the lamp up to 200W 230 V or 100 W 120 V At this connection the fan will be switched Gan intelligent fan Wiring diagram 1 Land N terminals are connected to live and neutral respectively The fan is always in standby mode and does not run As 24 HOURS Mode is activated the fan runs permanently at low speed to ensure minimum round the clock ventilation As motion sensor is activated for iFan Move only the fan switches to SILENT mode After no motion is detected the fan reverts to standby mode As humidity level increases the fan switches to MAX mode by default or to SILENT mode After humidity level drops the fan reverts to standby mode Humidity change eZ Standby mode O7 fan does not run or 24 Hours mode fan operated at 40 33 m h Turn on delay
10. fe Do not dispose the product with unsorted municipal trash Read the present user s manual carefully before proceeding with installation works Compliance with the manual requirements ensures reliable operation and long service life of the product Keep the user s manual available as long as you use the product You may need to re read the information on the product servicing DELIVERY SET The delivery set includes 1 Fan 1 pce 2 Logo 1 pce 3 Spigot 100 mm 1 pce 4 Spigot 125 mm 1 pce 5 Screws and dowels 4 pcs 6 User s manual 1 pce DESCRIPTION Due to constant improvements the design of some models may slightly differ from that one described in this manual The product described herein is the axial fan made of high quality plastic designed for extract ventilation of small and medium sized residential premises that are heated during winter period Table 1 Voltage W 100 240 Frequency Hz 50 60 Max power W 3 8 Current A 0 03 RPM min 2200 Max air capacity m h 133 Ingress Protection IP 44 Weight kg 0 35 intelligent fan Table 2 Model Spigot Speed Max air capacity Noise level at 3ml Air capacity Air capacity dia m h dBA factory settings m h regulation range m h 24 Hours 33 Silent 33 72 Overall dimensions external switch is closed The fan has four ventilation modes 1 St
11. he Customer s ensuring compliance with the rules of transportation storage mounting and operation of the product In case of any malfunction of the product through the fault of the Manufacturing company within the warranty period service life the Customer shall have the right to elimination of the manufacturing defects by means of warranty servicing performed free of charge The warranty servicing implies performance of activities related to elimination of defects in the product aimed to provide intended use of the product by the customer The defects are eliminated either by replacing or repairing such a product or a part component thereof NOTE with the purpose of performing warranty servicing you please produce User Manual or other relevant substituting document and the payment document as an evidence of the purchase with indication of the sale date The product model shall comply with that one specified in the User Manual or other relevant substituting document With the purpose of performing warranty servicing please contact the trade company where you purchased the product If warranty servicing on the spot proves impossible you will be provided with the necessary information regarding rendering of this service Manufacturer s warranty shall not apply in the following cases in case the customer fails to provide the product in complete according to the package contents specified in the User Manual or other relevant substituting document in
12. is mode is turned off EXTRA MODE INTERVAL VENTILATION Automatic function It can not be adjusted or turned off After 15 hours standstill the fan is switched on for 2 hours to ventilate the room with air capacity 72 m3 h If the fan receives a signal from a sensor during interval ventilation operation it switches to the mode according to the activated sensor Gtan intelligent fan RESET TO FACTORY SETTINGS The fan side panel incorporates a built in manual power slide switch Turn the fan off with this power switch press the button MODE on the control panel hold this button and switch the fan on with this slide power switch When the fan turns on hold the button MODE within 5 seconds until the light under the button stops blinking green Push MAINTENANCE Disconnect the fan from power mains prior to any maintenance operations Maintenance means periodic clearing of the fan surfaces from dust and dirt To clean the fan use a soft cloth wetted in a water soap solution Wipe the surfaces dry after washing Avoid liquid splashes on the motor and the circuit board intelligent fan way fe a STORAGE AND TRANSPORTATION RULES Transport the product by any transportation vehicle in the manufacturer s original package Store the product in the manufacturer s original packing box in a dry ventilated premise w
13. is time is adjustable To adjust the time press the button TIMER The default time is 5 minutes TURN ON DELAY TIMER ADJUSTMENT If you have to visit the bathroom often you can adjust the turn on delay timer to avoid the fan unnecessary switching After humidity increases or after signal from the external switch motion sensor the fan switches to higher speed not immediately but in some time period To change this time 0 2 or 5 minutes press and hold the button SWITCH DELAY and synchronously press the button TIMER The default time is 0 minutes Press the button TIMER together with the button SWITCH DELAY once to display the current setting TIMER TIMER Gan intelligent fan SWITCHING MOTION SENSOR wore FOR IFAN MOVE MODEL z The motion sensor is off by default Press the button On Off move to switch it on switcH DELAY The light indicator Status under the button glows when the motion sensor is turned on status Press the button On Off move once to display the current setting SWITCHING 24 HOURS MODE 24 HOURS In this mode the fan has minimum air capacity before the humidity sensor motion sensor or external switch is activated Press the button 24 Hours to switch this function on The green light indicator under this button glows when 24 Hours mode is on To turn this mode off press the button 24 Hours This function is not available for wiring diagram 2 By default th
14. ith the temperature range from 5 C up to 40 C and relative humidity less than 80 The storage environment must not contain dust acid or alkali vapours that may cause corrosion of the product parts Gan intelligent fan mo for the product mounting OPERATION RULES The fan is designed for connection to single phase ac 100 240 V 50 60 Hz power mains The fan is designed for continuous operation always connected to power mains The fan is rated for operation at the ambient temperature ranging from 1 C go 45 C The fan is double insulated and requires no grounding The fan complies with the requirements according to the EU norms and directives to the relevant EU Low Voltage Equipment Directives EU Directives on Electromagnetic Compatibility 220 240 V 50 Hz or 12 V 50 Hz MANUFACTURER S WARRANTY The fan is manufactured at the factory of Ventilation systems PrJSC hereinafter referred to as the Manufacturer By purchasing this product the customer confirms to have read and agreed to the terms rules and requirements related to operation storage transportation mounting adjustment connection maintenance and repair as well as warranty obligations with respect to this product as set forth in the manufacturer s accompanying documentation to the product The manufacturing company sets forth the warranty period service life of the product as 60 months following the sale date via retail network subject to t
15. r and the casing before starting installation The casing internals must be free of any foreign objects which can damage the impeller blades Misuse of the device or any unauthorized modification is not allowed The fan is not to be used by children and persons with reduced physical mental or sensory capacities without proper practical experience or expertise unless they are controlled or instructed on the product operation by the person s responsible for their safety Do not leave children unattended and do not let them play with the product Take steps to prevent ingress of smoke carbon monoxide and other combustion products into the room through open chimney flues or other fire protection devices Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting Operating medium must not contain any dust or other solid impurities sticky substances or fibrous materials Do not use the fan in the environment containing hazardous or explosive materials and vapours i e spirits gasoline insecticides etc Do not close or block the fan intake or extract vents in order to ensure the most effective air passage Do not sit on the fan and do not put objects on the fan Fulfill the requirements stated in this user s manual to ensure long service life of the product 2 Gian intelligent fan N WARNING Recycle at the end of the service li
16. reases the fan switches to higher speed to extract excessive humidity After the indoor humidity drops to standard level the humidity timer activates and the fan operates throughout the time period set for the humidity extraction timer Pe EENE After that the fan reverts to the previous operation mode If humidity level increases less fei than by 20 within 10 minutes the fan run out time becomes 15 minutes Select the humidity extraction mode by pressing the button Humidity mode O Si Max active humidity response mode with the best impeller performance sb w sian wh Silent active humidity response mode with silent operation SILENT MAX Press the button Humidity mode once to display the current mode Note Stabilization of humidity is understood as humidity change no more than by 3 within 5 minutes tan inteligent fan HUMIDITY EXTRACTION MODE ADJUSTMENT After the humidity level stabilization the fan continues operating for some time period at higher speed to ensure full excessive humidity extraction This time is adjustable To adjust the time press and hold the button MODE and synchronously press the button TIMER The default time is 30 minutes Press the button TIMER together with the button MODE once to display the current setting OFF DELAY TIMER ADJUSTMENT When the motion sensor is activated or the external switch is closed the fan operates for some time and then reverts to standby mode Th
17. ty change e urn on delay lt M timer starts 0 2 5 min T b Signal to LI terminal Turn on delay light is on timer starts 0 2 5 min ea MAX SILENT gt mode is activated Humidity stabilization Humidity extraction timer starts 30 45 60 min Fan operation in Silent mode Motion y Signal to LI terminal if off light is off Turn on delay timer starts 5 15 30 min Gtan Intelligent fan FAN ADJUSTMENTS The fan is adjusted at the factory and is ready for operation It is a fully operable product without extra adjustments However if you want to adjust the fan according to your needs please follow the instruction below You can always reset to the factory settings Factory setting parameters spigot 125 spigot 100 speed in standby mode 0 m h speed in 24 Hours mode 40 33 m h speed in Silent mode 83 72 m h speed in Max mode 97 82 m h humidity extraction Max mode turn on delay time 0 min off delay time 5 min humidity extraction time 30 min motion sensor for iFan Move is included CONTROL PANEL iFan model iFan Move model HUMIDITY MODE TIMER SPEED 24 HOURS HUMIDITY MODE TIMER SPEED OMOR 24 HOURS eeeee SWITCH DELAY STATUS FAN OPERATION INDICATION The fan is turned on by the motion sensor or external switch the light

Download Pdf Manuals

image

Related Search

Related Contents

Konica Minolta 125 Digital Camera User Manual  Technics SB-CSS150 User's Manual  Manual - DATAQ Instruments    - Service, Support  KOHLER K-14410-4-BGD Installation Guide  

Copyright © All rights reserved.
Failed to retrieve file