1. The software is not suitable for the configuration and diagnostics of devices supplied by other manufacturers The devices in the CDS are always displayed in so called projects The Configuration amp Diagnostic Software allows you to e create a new project configure the devices and later transfer the configuration to the devices You can then save the project created e identify devices connected to the PC and receive the existing configuration of the devices and then transfer it back to the devices In this way a new project is created in the CDS that you can save e open a project saved previously and transfer the configuration to devices of the same type with the same type code and for the same application The configuration of the devices is password protected with the effect that only the members of the appropriate user groups will be able to transfer configurations to the devices You can also use the Configuration amp Diagnostic Software to perform diagnostics on connected devices e g in the case of an error The diagnostics data will be displayed on the monitor Project Y gt Identify New Open Y i i e Connect PC to device s e Receive configuration e Add device s e Create configuration e Connect to device s e Connect to device s e Logon e Transfer configuration e Log on e Log on Edit configuration e Transfer configuration Transfer configurati
2. amp ASICK CDS ri sa HI Rz ud PE 5 R 2 dI ty NOVO H3 STI iguration amp Diagnostic Software Conf CDS SICK User Manual CDS This document is protected by the law of copyright whereby all rights established therein remain with the com pany SICK AG Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law Alteration or abridgement of the document is not permitted without the explicit written approval of the company SICK AG SICK AG Industrial Safety Systems Germany All rights reserved 8 009 241 N248 11 02 03 User Manual CDS 8 009 241 N248 11 02 03 Contents Contents 1 On the documentation 5 reae Leer cacio ne ai 4 1 3 F hction of this COCUMENT i seis astio iaia ha 4 1 2 TargetgroUp csi een e dtd ide dte bte pee e ied aaa 4 1 3 Depthrof informationis sa salesiano iaia 4 L4 M No oS ioa iaia 4 1 5 Symbols and formats used cccccceceessceeeeseeeeeeeeeeeeeeeeeeeseeeeseesaeeeeeseeeeesscaeeeseneaeeeeeas 4 1 6 Accessing the documentation ii 5 1 7 Using the online help function ii 5 1 8 How to use this docum epi uidere ede Era inrer aaa 8 Installation of the software ssssssssssssssssnesssssnesnsssssonssnessnesnesnssonsonesossonesnesonsonesnssoneenssnssonsonesnnsoneenseent 9 Product GCESCHIPtION nsssscsecsesesneenssnesnecnsenseneneeneenssnssns
3. Active means that the device has a complementary unit to which a ia connection has been made via the interface and that the comple mentary unit has been identified by the CDS _ Passive devices are shown in grey de Passive means that there is at present no connection to this device a either because it is currently disconnected or because it could not be identified This is important particularly in devices such as the C 4000 safety light curtain that consists of sender and receiver As the PC with the CDS can be connected only to the sender or the receiver the complementary unit is always shown in the passive mode You can identify the device to which the PC is connected by the Eg device symbol showing a PC Unknown or unidentified devices are shown with a question mark The device status is symbolised by the colour of the lettering Font colour Meaning Configured devices are shown with blue lettering SICK protective device Non configured devices or devices in which a malfunction SICK protective device has occurred are shown with red lettering Devices where the CDS is unable to identify their status SICK protective device not connected not identified are shown with grey lettering 5 2 Changing project names You can change the name of a project When a project is saved the CDS uses the project name as the default file name For the project name use names for instance
4. with which you can allocate your projects to the machines or plant that are protected 5 3 Comparing with a project file You can also compare a project saved and or opened in the CDS with a saved project file A dialog box will show the saved project on the left and on the right a comparison protocol In this dialog box you can open the project file compared with the open project SICK AG Industrial Safety Systems Germany All rights reserved 17 Chapter 5 18 Working with projects User Manual CDS 5 4 Adding devices If you have created your own project in the CDS you can also add one or several devices The device selection wizard will assist you in this step The class of devices you can select there will depend on which device classes have been installed Added devices can be deleted again from the project The commands necessary to carry out the above described functions are found in the con text menu of the project Please refer to the online help for detailed instructions 5 5 Properties To check the type codes and the serial numbers of the devices you can display the properties of a project and or the properties of a single device The list shows all type codes and the serial numbers of the devices SICK AG Industrial Safety Systems Germany All rights reserved 8 009 241 N248 11 02 03 User Manual Communication Chapter 6 CDS Communication The software communicates with the devices via a cable
5. can result in injury or death Always begin the configuration by creating a new configuration draft in the CDS or by editing a configuration draft received from the devices Generate or edit the configuration draft either with the help of the configuration wizard or in a configuration dialog box with file cards For the actual configuration of the devices supplied by SICK AG Industrial Safety Systems transfer the configuration draft to the connected devices After sending the configuration draft a configuration protocol will be displayed which you must first release before the configuration is enabled in the devices Note You can transfer the configuration draft to devices or a device system only if your PC is Fig 18 Status bar with check mark for configuration verified Note connected to the devices and if you are registered as user in the appropriate user group of the devices The configuration draft of a single device can also be exported and imported to other de vices with the same type code Verified configuration draft As soon as a configuration draft has been sent and released by an Authorised client it is deemed to be verified You can see this by a green tick or check in the status bar EEK The project with the verified configuration draft can then be saved and later be opened and sent also to other devices by the machine maintenance personnel When a project is opened the green check mark in the statu
6. counter nr Both numbers can be found in the Reset password dialog box When you reset the password for a device it is configured as on delivery For operation to be possible you must re edit the configuration as delivered or transfer a suitable previous ly saved and verified configuration to the device SICK AG Industrial Safety Systems Germany All rights reserved 8 009 241 N248 11 02 03 User Manual CDS Diagnostics data Chapter 8 Diagnostics data Note 8 009 241 N248 11 02 03 With the aid of the CDS you can perform diagnostics on devices connected and linked to the CDS or identified by the CDS To do so load the diagnostics data to the viewing area of the monitor As soon as the diagnostics data is displayed the standard menus of the software will dis appear Then only the Project menu and the related buttons are available The navigation area of the CDS can no longer be used You can print and save the diagnostics data You can also insert a comment via an addi tional dialog box This comment will also be printed and saved The commands necessary to carry out the above described functions are found in the con text menu of the devices under Diagnostics Please refer to the online help for a specific description and detailed instructions 8 1 Comments You can add comments to the reports displayed in the viewing area of the CDS These comments are also printed with the appropriate report and saved SICK
7. link To make sure that the data communication between your PC and the connected devices functions correctly you must select a communication protocol m On the Extras menu of the CDS you will find the Communication connection command E Please refer to the online help for detailed instructions Fig 17 Selecting the communication protocol Communication connection x m Protocol T 1 E Serial communication RK 512 x 103 OK Cancel Help For the RLS 100 choose the communication protocol RLS protocol For the other SICK devices choose the communication protocol Serial communication RK 512 In addition you must specify one COM port of your PC as the connection for the devices Also from the connections available on your PC select the one where the devices are con nected Note The connection you select must not be used by any other peripheral e g a mouse If you do the system will not function correctly 8 009 241 N248 11 02 03 SICK AG Industrial Safety Systems Germany All rights reserved 19 Chapter 7 Configuration User Manual CDS Configuration Using the CDS you can configure the SICK protective devices Plan your configuration carefully The configuration of SICK protective devices must be carried out with the greatest accura WARNING y and must match the status and the condition of the machine or system to be monitored Incorrect configurations
8. separately using the command Programs SICK Applications Help on SICK CDS or in the CDS in the menu From one of the CDS dialog boxes click the Help button in the dialog box or press the F1 key The related description for the dialog box is then displayed automatically 8 009 241 N248 11 02 03 SICK AG Industrial Safety Systems Germany All rights reserved 5 Chapter 1 Fig 2 Example for the de scription of a CDS dialog box Fig 3 Detailed instructions button Fig 4 Topics found dialog box On the documentation User Manual CDS User groups There are various user groups in the devices from SICK AG Industrial Safety Systems These user groups have different authorisations e g for transferring configurations to the devices or to perform diagnostics on the devices If the devices in a project have been identified by the CDS or the CDS is linked to the devices for a project you can change to these user groups When the CDS is started you will automatically belong to the user group Machine operator To be able to send configurations log in with the device or the device system as Machine maintenance personnel or as Authorised client using the appropriate project password The factory set password SICKSAFE has been entered for the user group Authorised client exception on the RLS 100 the password is RLS1 If you wish to secure access to the configuration of the devices you must change this p rd in each c
9. AG Industrial Safety Systems Germany All rights reserved 25 Chapter 9 26 Annex User Manual Annex 9 1 Tab 1 Tab 2 Tab 3 Tab 4 9 2 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8 Fig 9 Fig 10 Fig 11 Fig 12 Fig 13 Fig 14 Fig 15 Fig 16 Fig 17 Fig 18 Fig 19 Fig 20 Fig 21 CDS List of tables Typical procedure in the CDS recreo aeree 10 Function keys and key shortc ts ciiin akini eniai aaia aiaa aaea 14 Meaning of the symbols eese eene nnne nnne nnne nnne nnne 17 Meaning of the font colours esseesessssseseeeeeeeeeeneeennnee nennen nnne 17 List of illustrations List of contents of the online hEIp in 5 Example for the description of a CDS dialog box 6 Detailed instructions button nnne 6 Topics found dialog DOX i 6 Example step by step INStrUctioNns iii 7 Device specific subjects liMkK ii 7 Contents DUTON wid uci rera cer eder atten rede v ve ea Pe ra En deth 7 Links to the operating instructions iii 7 User interface of the CDS 11 Menu bar WIth tool tipuosa ee 11 Status bar with symbols for connected and configuration verified 12 Status bar with symbols for not connected and configuration not VErIfied rari 12 Example of a context Menu 12 Navigation area left and
10. CDS You will find the number on the booklet with the installation CD gt Then go to the SICK Configuration amp Diagnostic Software dialog box and select under Read documentation the required operating instructions and click the OK button beside the selection Acrobat Reader will open gt Accept the licence agreement The selected operating instructions are opened 17 Using the online help function The CDS is available with an online help function which provides information on the soft ware functions and which provides a step by step description of the individual actions The online help has a table of contents and an index The following sections of the docu mentation can be opened in the list of contents for the online help e user manual on the CDS in Portable Document Format PDF e online help on the CDS online help on device specific subjects e g configuration procedures e operating instructions for the devices supplied by SICK AG Industrial Safety Systems in Portable Document Format PDF Fig 1 List of contents of the online help ranual ua Configuration amp Diagnostic Software On the documentation id 2 Overview 12 Menu symbol and status bar 2 Navigation and viewing area ki Printer setup 2 Selecting the language 12 Keyboard commands 2 Directory structure of the programme Working with projects Configuration Diagnosis data mH i m The online help function can be opened
11. Phone 49 2 11 53 01 0 Fax 492 11 53 01 100 Great Britain Phone 44 17 27 83 11 21 Fax 44 17 27 85 67 67 Italy Phone 39 02 92 14 20 62 Fax 39 02 92 14 20 67 Japan Phone 813 33 58 13 41 Fax 813 33 58 9048 Korea Phone 82 2 786 63 21 4 Fax 822 786 63 25 Netherlands Phone 31 30 229 25 44 Fax 31 30 2293994 Norway Phone 47 67 56 75 00 Fax 47 67 56 66 10 Poland Phone 48 22 8 37 40 50 Fax 48 228374388 Singapore Phone 65 67 44 37 32 Fax 65 68417747 Spain Phone 34 93 4 80 3100 Fax 34 93 4 73 44 69 Sweden Phone 46 8 6 80 64 50 Fax 46 87101875 Switzerland Phone 41 4 16 19 29 39 Fax 41 416 19 29 21 Taiwan Phone 88 62 23 65 62 92 Fax 88 62 23 68 73 97 USA Canada Mexico Phone 1 952 9 41 67 80 Fax 1 952 9 41 92 87 Representatives and agencies in all major industrial nations SICK SICK AG Industrial Safety Systems P O Box 310 79177 Waldkirch Deutschland Phone 49 76 81 2 02 0 Fax 49 76 81 2 02 38 15 www sick com
12. Safety Systems Germany All rights reserved 15 Chapter 5 Working with projects User Manual CDS How to connect the PC to a device from SICK AG Industrial Safety Systems Connect the 9 pin SubD plug of the connecting cable to a serial interface of your PC Fig 16 Connection of the PC e g to a device from SICK AG Industrial Safety Systems Remove the protective cap on the configuration socket of the device supplied by SICK AG Industrial Safety Systems Connect the M 8x4 plug to the configuration socket of the device and or the device cluster Notes Ensure that the configuration cable is not laid in close proximity to high power electrical drives or cables carrying high power In this way you will avoid EMC effects on the confi guration cable e When devices consisting of senders and receivers are involved initially connect the receiver because it needs to be connected and configured first 16 SICK AG Industrial Safety Systems Germany All rights reserved 8 009 241 N248 11 02 03 User Manual CDS Tab 3 Meaning of the symbols Tab 4 Meaning of the font colours 8 009 241 N248 11 02 03 Working with projects Chapter 5 5 1 The project tree The project tree of the devices is shown in the navigation area The devices existing in the project tree can be displayed in the active or in the passive mode Example symbols Meaning Active devices are shown in colour E
13. allation close all other programmes The minimum system requirements for the operation of the Configuration amp Diagnostic Software are e standard Intel Pentium PC 233 MHz 64 MB RAM e spare hard disk space CDS 15 MB documentation 100 MB e graphics resolution 800 x 600 pixels with High Color 16 bit e RS 232 serial interface that is not used by any other programs e operating system MS Windows 95 98 NT4 0 2000 XP e a printer driver of your choice must be installed During the installation you can install Acrobat Reader Using this program you can read the user manual for the CDS and the operating instructions for devices from SICK AG Industrial Safety Systems How to install the CDS Start your PC and place the installation CD in your CD ROM drive The installation wizard will start automatically It allows you to open the documentation and to install the software First enter the serial number for the CDS You will find the number on the booklet with the installation CD Then go to the dialog box SICK Configuration amp Diagnostic Software and select Install software SICK CDS and click the OK button beside the selection Follow the instructions in the installation wizard e The CDS and the installation wizard for the CDS are available in five languages The soft ware detects the regional settings in your operating system and starts the wizard in the related language However if your operating system i
14. ased You can print and save the configuration protocol You can also insert a comment via an additional dialog box This comment will also be printed and saved Carefully check the configuration protocol Carefully check to make sure that the configuration data displayed comply with those you actually wanted to enter Check for typing and transfer errors Once you have successfully transferred the configuration the machine or plant must be checked and released by specialist personnel e The new configuration will be activated on the device only after release If you reject the configuration then the device or device cluster receives an invalid configuration The commands necessary to carry out the above described functions are found in the Project menu and in the context menus of the devices gt Carefully check each individual item of the configuration protocol gt Some configuration protocols for devices have several pages In this case page to the previous following pages using the buttons at the bottom of the scroll bar or using the Page up Page down keys 22 SICK AG Industrial Safety Systems Germany All rights reserved 8 009 241 N248 11 02 03 User Manual CDS Fig 21 Buttons for paging through the configuration protocol Note AN WARNING 8 009 241 N248 11 02 03 Configuration Chapter 7 z E gt Also carefully check the following pages of the configuration protocol The Release but ton only bec
15. carefully before working with this documentation and the Configu ration amp Diagnostic Software 11 Function of this document This user manual instructs the machine operator s technical personnel in the operation of the Configuration amp Diagnostic Software for protective devices supplied by SICK AG It does not provide instructions on the operation commissioning and maintenance of the protective devices themselves Please refer to the documentation enclosed with the pro tective devices for information on operation commissioning and maintenance 12 Target group This software documentation addresses planners developers and operators of systems that are to be protected by one or more protective devices supplied by SICK AG It also addresses people who integrate these protective devices into a machine carry out machine commissioning or who are in charge of servicing and maintaining the unit 13 Depth of information This software documentation contains information on the Configuration amp Diagnostic Soft ware for protective devices supplied by SICK AG The user manual provides an overview of the basic software functions Please refer to the online help function for more detailed in structions on the configuration of devices and performing diagnostics Planning and using protective devices also require specific technical skills which are not detailed in this documentation Further information on health and safety at work and accid
16. e user interface includes title bar menu bar toolbar the navigation area the viewing area and the status bar How to close the software On the Project menu choose the Quit command The program window will be closed If at this point you have as yet not saved the data of an open project you will be prompted to do so 4 1 Menu bar toolbar and status bar The menu bar and the toolbar are found at the top of the software window The menu bar includes the commands for the fundamental operation of the software whereas the tool bar provides the most important commands in the shape of buttons Moving over a button will open a brief information tag tool tip on the function of the button Project Edit View Extras a wok 1 Save project Ctrl 5 SICK AG Industrial Safety Systems Germany All rights reserved 11 Chapter 4 Fig 11 Status bar with symbols for connected and configuration verified Fig 12 Status bar with symbols for not connected and configuration not verified Fig 13 Example of a context menu Note User interface User Manual CDS The status bar is at the bottom of the software window There the following is displayed e the status of the program execution and progress if the action is protracted e the user group to which you currently belong e the name of the project or device in the navigation area e whether the CDS is connected to a device
17. e whether the configuration has been verified p M z du fe z The toolbar and the status bar can be shown or hidden 4 2 Navigation and viewing area The navigation area shows the devices in a device cluster hierarchically in a project tree This project tree consists of a project symbol and one or several device symbols In the navigation area you can open various commands using the context menus for the project or the devices El a Project 1 E C 4000 Standalone sender Protocol Diagnosis Access rights Delete device If some commands are only displayed in grey then the commands are currently not avail able because the CDS for example is not connected to a device or your access rights are inadequate 12 SICK AG Industrial Safety Systems Germany All rights reserved 8 009 241 N248 11 02 03 User Manual CDS Fig 14 Navigation area left and viewing area right of the CDS Note Fig 15 Status bar with symbols for connected and configuration verified Note 8 009 241 N248 11 02 03 User interface Chapter 4 g7 SICK CDS Project Edit View Extras elal en sha Project 1 Ci 5 Bus node UE 4100 PROFIsafe Bm E General system configuration Beam coding Non coded External device monitoring Inactive Key operated pushbutton for byp Two channel equivalent circuit NA Teach in key operated switch Inactive Emergency sto
18. ed using devices which have already been configured the individual devices may have different passwords In this case you will be asked for your password separately for each device Once you have entered the correct passwords for all devices the password for the first de vice will be assigned to all devices Change to the Machine operator user group If you leave the PC unattended when it is connected to devices you must change to the Machine operator user group in order that no unauthorised persons can transfer configu rations to the devices 7 4 Change project password The user group Authorised client can enter change the passwords for the user groups Machine maintenance personnel and Authorised client on the RLS 100 only for the Authorised client user group The passwords will be saved in the devices This allows the devices to be protected from being configured by unauthorised persons SICK AG Industrial Safety Systems Germany All rights reserved 23 Chapter 7 24 Note Configuration User Manual CDS 75 Reset password If you have forgotten the password for a device you can reset the password To do so you need what is called a reset password You will get this password once you have identified yourself in writing to the manufacturer For this purpose use the form Faxform pdf on the CDS CD ROM For the identification you will need the serial number of the device and the number of the device counter Device
19. ent prevention and on opto electronic protective devices is found in the brochure Safe Machines with opto electronic protective devices 14 Abbreviations SICK Configuration amp Diagnostic Software Portable Document Format for Adobe Acrobat Reader 15 Symbols and formats used Instructions for taking action are shown by an arrow Carefully read and follow the instruc tions for action Refer to notes for special features of the software or of a device Software notes show the location in the CDS where you can make the appropriate settings and adjustments Warning Warnings indicate real or potential hazards and risks They are designed to prevent physical injury or death Carefully read and follow the warning notices SICK AG Industrial Safety Systems e Germany All rights reserved 8 009 241 N248 11 02 03 User Manual On the documentation Chapter 1 CDS v1 6 Accessing the documentation During the installation of the individual software components e g for the C 4000 or S 3000 the related operating instructions for the device are also installed You can access the operating instructions from the CDS online help In addition you can also open the operating instructions directly from the installation CD How to open a set of operating instructions Start your PC and place the installation CD in your CD ROM drive The installation wizard will start automatically gt First enter the serial number for the
20. g and or exporting configuration drafts projects CDS default for saving project files system This directory holds the system specific CDS files You must not save any other files in this directory SICK AG Industrial Safety Systems Germany All rights reserved 8 009 241 N248 11 02 03 User Manual CDS Working with projects Chapter 5 Working with projects Notes AN WARNING 8 009 241 N248 11 02 03 The devices which you configure maintain or perform diagnostics with the CDS are managed in projects and shown in a project tree Using the CDS you can assemble projects offline and then configure and save them In this way for example for the initial configuration of SICK protective devices for a plant you can first plan the configuration on the screen and later transfer it to one or more identical devices When the project is created it is given a name that you can change Add devices to the project tree of a new project A second way of creating a project is to have the CDS identify devices already wired up In this way a project with all identified devices is displayed in the navigation area of the CDS The commands necessary to carry out the above described functions are found in the Project menu Please refer to the online help for a device specific description and detailed instructions e During project identification the software only identifies the type of devices connected and identifies these To ens
21. nced erating instructions ar iced operating instructions In this case you should also use the design with extension connection for Q amp Projects using the C 4000 standalone or Guest 2 devices Ada C 4000 to projects Q amp c 4000 configuration To do so you must have the related file in PDF format and Adobe Acrobat Reader in stalled on your PC If this is not the case a warning is displayed SICK AG Industrial Safety Systems Germany All rights reserved 7 Chapter 1 On the documentation User Manual CDS 18 How to use this document After you have carefully read the above sections please note the following notes on the document e f the software is as yet not installed please read the chapter Installation in this user manual e f you are working with the software for the first time please read the chapter Product description e f you are familiar with the software and want to configure devices please read the chap ter Configuration e f you are familiar with the software and want to perform diagnostics on devices please read the chapter Diagnostics SICK AG Industrial Safety Systems Germany All rights reserved 8 009 241 N248 11 02 03 User Manual CDS Installation of the software Chapter 2 Installation of the software Note Notes 8 009 241 N248 11 02 03 An installation wizard will guide you through the installation of the software Before begin ning the inst
22. omes available when you have paged through to the last page of the configu ration protocol Click the Release button The configuration data will be loaded to the device devices and initialised with the new configuration If the loading has been successful an appropriate message will appear Click the OK button The configuration loaded to the device devices is now active Test whether the device s monitor the machine or plant as you expect Only after com pleting this step go to real time operation 7 3 User groups There are various user groups in the devices from SICK AG Industrial Safety Systems These user groups have different authorisations e g for transferring configurations to the devices or to perform diagnostics on the devices If the devices in a project have been identified by the CDS or the CDS is linked to the de vices for a project you can change to these user groups When the CDS is started you will automatically belong to the user group Machine operator To be able to send configura tions log in with the device or the device system as Machine maintenance personnel or as Authorised client using the appropriate project password The factory set password SICKSAFE has been entered for the user group Authorised client exception on the RLS 100 the password is RLS1 In order to protect the access to the configuration of the devices you must change this password If a device cluster has been assembl
23. on e Save project e Save project Test the devices for operational readiness The software is unable to determine if a device is mounted operationally or not Once you have successfully transferred the configuration drafts check to see if the SICK protective devices actually monitor your machine or system the way you intended In this case pay attention to the instructions on commissioning and for the daily check in the operating instructions for the related device All values have been computed by the PC on which the CDS runs SICK AG is therefore unable to warrant that no computer specific computing errors will occur 8 009 241 N248 11 02 03 User Manual CDS User interface Chapter 4 User interface m Fig 9 User interface of the CDS Fig 10 Menu bar with tool tip 8 009 241 N248 11 02 03 How to start the software Go to the Start menu and select the command Programs SICK Applications SICK CDS The Configuration amp Diagnostic Software will now be started Once the program has started the screen is initially blank Device combinations saved or identified will thereafter be shown graphically in the user interface These can then be used to configure or perform diagnostics on SICK protective devices Title bar Menu bar Toolbar A Va gA SICK CDS Project Edit View Extras olele cija Machine operat Ld TS Z Navigation area Viewing area Status bar Th
24. onfigured device Note If a device cluster has been assembled using devices which have already been configured the individual devices may have different passwords In this case you will be asked for your password separately for each device Once you have entered the correct passwords for all devices the password for the first device will be assigned to all devices Change to the Machine operator user group If you leave the PC unattended when it is connected to devices you must change to the Machine operator user group in order that no unauthorised WARNING persons can transfer configurations to the devices Detailed instructions The descriptions in the online help explain the functions and relationships in the dialog boxes Use the Detailed instructions button in the descriptions to go to the step by step instructions of the online help Detailed instructions If several sets of step by step instructions are available the Topics found dialog box is opened Choose there the required topic and click the Display button ow to edit a configuration draft ow to export a configuration draft ow to transfer the configuration to the devices 6 SICK AG Industrial Safety Systems Germany All rights reserved 8 009 241 N248 11 02 03 User Manual CDS Fig 5 Example step by step instructions Fig 6 Device specific subjects link Fig 7 Contents button Fig 8 Links to
25. p Inactive 7 segment display rotated 0 Assignment of the signal output None Scanning range 0 25m Number of operating modes 1 p E configuratior P OP Parameter node Machine operator General The viewing area is located to the right next to the navigation area and is initially blank In the viewing area of the CDS e the diagnostics data is displayed when you have performed diagnostics e the configuration protocol is displayed when you have transferred a configuration to a device e the parameters for a device are displayed when you click one of the device parameter nodes e the configuration data currently in the CDS is displayed when you display the configuration draft for a device Only when it is indicated in the status line that the CDS is linked to the connected devices and that the configuration draft is verified it is ensured that the data displayed for a parameter node or the configuration draft matches the data in the devices Eau You can change the size ratio of navigation area and viewing area 4 3 Selecting the language The CDS can be operated in a variety of different languages Select the appropriate lan guage in the Extras menu The project tree and the context menu of the project tree will change its associated lan guage only after a new project is generated or after a project has been identified or opened SICK AG Industrial Safety Systems Germany All righ
26. s line is only displayed after the CDS is linked to the related device If the open configuration draft is changed a red cross appears in the status line The confi guration draft can no longer be transferred by machine maintenance personnel The commands necessary to carry out the above described functions are found in the con text menus of the device symbols Please refer to the online help for a device specific de scription and detailed instructions 20 SICK AG Industrial Safety Systems Germany All rights reserved 8 009 241 N248 11 02 03 User Manual CDS AN WARNING Note Fig 19 Dialog box for the configuration wizard based on the example of the S 3000 8 009 241 N248 11 02 03 Configuration Chapter 7 7 1 File cards or wizard You can create the configuration draft per device from SICK AG Industrial Safety Systems either with the help of the configuration wizard or with the file cards e The configuration wizard will guide you step by step through the configuration from the first to the last setting You will find explanatory text on the individual configuration steps in the related dialog box e The file cards allow you to specifically change one or several configuration parameters Check the content of all file cards Unlike the configuration wizard in the file card view you are not automatically guided through all configuration points For this reason check the content on all file cards to ensure
27. s set for another country than the available languages e g Dutch the Select language dialog box appears before the SICK Configuration amp Diagnostic Software dialog box Select the desired language e g English During the installation of the CDS choose the software components to be installed C 4000 S 3000 Components that have already been installed with a previous version of the CDS are selected automatically and updated as necessary If Windows does not start the installation wizard automatically Click Run in the Start menu Enter the following command line in the Open field Drive letter for your CD ROM drive setup exe The Serial number dialog box will open SICK AG Industrial Safety Systems Germany All rights reserved 9 Chapter 3 User Manual CDS Product description Product description Note Tab 1 Typical procedure in the CDS AN WARNING 10 SICK AG Industrial Safety Systems e Germany All rights reserved Devices from SICK AG Industrial Safety Systems such as safety light curtains safety laser scanners bus nodes or configurable small controllers can be configured differently depending on the application and operating mode The Configuration amp Diagnostic Software has a graphic user interface which allows you to configure and diagnose devices supplied by SICK AG Industrial Safety Systems The para meters for a configuration are transferred to the devices and saved there
28. snsoneoneneeneensonsensenseuseueneeneeneeneeneonseueeueceeneeneenesn 10 4 Userinterface 4 1 Menu bar toolbar and status bar 4 2 Navigation and viewing area i 4 3 Selecting the language si sal alia altari 44 Keyboard commands illa aaa aaa 4 5 Directory structure for the program ui 14 5 Working with projects 5 nel ei onina inanan inimicizie 15 5 1 The project tree 5 2 Changing project nales eterni iaia 17 5 3 Comparing with a project file ii 17 5 4 Adding deviCes iiec oen Ad decks iaia carie 18 5 5 Properties MP MI aa 18 6 COMMUNICA m 19 ravcoduriupee ii 20 1 3 File cards or WIZardi coercere prre rr ERES areak AE rr de rre ces 21 7 2 Configuration protocol uie ecran ratae niente in ieuan ba ena ir De aae nnd dead 22 TiS USEP SOUPS 23 T A Change project password essei ee eeeeee essen nennen nenne nnn nene n nnne nnne nennt 23 T b Reset paSssWords u E 24 8 Diagnostics data aas Ni 25 8 1 Comments SICK AG Industrial Safety Systems Germany All rights reserved 3 Chapter 1 On the documentation User Manual CDS On the documentation CDS PDF Take action Note i AN WARNING Please read this chapter
29. tes Configuration User Manual CDS Configuration Receiver Host x General Host Operating mode 1 Application name BA13 D46 max 22 characters External device monitoring Assignment of the signal output Inactive C Active None ae ICE TNS TOUR Contamination pon coding 7 Status of the OSSD safety switching output with ji 11 Non coded delay by s C Code1 S E C Code2 T Reset button active mr Hesetr Cj ane c e Cc TT Emergency stop active eat Operating mode EEA Key operated pushbutton for bypass Add Two channel equivalent circuit N O N 0 C Two channel complementary circuit N C N D Cancel Help 7 2 Configuration protocol As soon as the configuration protocol or the view containing the configuration draft is dis played the standard menus in the software are hidden Only the Project menu with the appropriate buttons will then be available The navigation area of the CDS can no longer be used After the configuration data has been transferred to one or several devices the configura tion protocol will be shown automatically During this process the actual data is read out from the device and displayed If the data read does not match the data in the configuration draft it will be shown in black If the data read out differs from that in the configuration draft it will be shown in red In this case the configuration protocol cannot be rele
30. that the configuration data matches your application The commands necessary to carry out the above described functions are found in the View Dialog box menu A system with several devices for example a cascaded system is in general configured in one single configuration wizard or one single dialog box with file cards Several runs through the setting dialog boxes will be completed resp the file cards will be repeatedly offered Configuration wizard Step 5 x Restart Scanner 1 ROB 013 Restart of the internal OSSDs Without restart interlock With restart interlock Time delayed by 2 Second Without restart interlock CAUTION Only if it is not possible to leave the protective field to approach the hazardous point The OSSDs are enabled immediately if there is no longer an object in the protective field With restart interlock The OSSDs are only enabled again when the operator operates the control switch for restarting or resetting Time delayed CAUTION Only if it is not possible to leave the protective field to approach the hazardous point The OSSDs are enabled when there is no longer an object in the protective field for the time given 2 60 s Continue gt Cancel Help SICK AG Industrial Safety Systems Germany All rights reserved 21 Chapter 7 Fig 20 Dialog with file cards based on the example of the C 4000 Note AN WARNING No
31. the operating instructions 8 009 241 N248 11 02 03 On the documentation Chapter 1 The step by step instructions describe the related procedure in detail How to receive the configuration from the devices Using the right mouse button open the context menu of a device or system On this menu choose the command Configuration draft Receive The previous configuration of all devices is read and can be edited in the CDS As the CDS is used for the configuration and diagnostics on a number of protective de vices from SICK AG along with the basic description there are device specific help sub jects From these basic descriptions you can open the device specific help subjects using the Device specific subjects link at the end of a dialog box description Zl Device specific subjects The Contents button in the dialog box descriptions and in the step by step instructions will always take you back to the list of contents Once back in the list of contents D and in the appropriate dialog box descriptions you can also open the operating instructions for the desired protective devices D 2 Configuration amp Diagnostic Software Note Certain functions of the receiver of a QI c 4000 Safety Light Curtain 2nd generation device can only be used in LE Operating instructions an extension connection to the C 4000 is c 4000 operating instructions see C 4000 Standardi STESSA va
32. ts reserved 13 Chapter 4 Tab 2 Function keys and key shortcuts 14 User interface User Manual CDS 4 4 Keyboard commands The CDS allows you to execute frequently used functions via function keys or with key shortcuts Function key or Description shortcut Ctrl N Create new project Ctrl O Open existing project Ctrl S Save project F1 Open the help utility F3 Identify connected project Shift F3 Select communication connection F4 Link connected project with open project FG Display properties of a project or device F7 Open the context menu F8 Change user group Alt F4 End CDS Esc Close dialog box without saving Cancel 4 5 Directory structure for the program To make it easier for you to navigate through created projects device configurations dia gnostics reports etc the program creates a directory structure in the directory chosen during installation This directory structure consists of sub directories for the individual types of files that you are allowed to save in the CDS backup This directory holds the program files of an earlier version saved after an update You must not save any other files in this directory device specific directories e g C 4000 UE 4150 This directory includes sub directories that are suggested as the directory when saving device specific files e g diagnostics report or configuration protocol import export CDS defaultfor importin
33. ure that you receive the configuration of the connected devices in the CDS the software will prompt you to receive the current configuration This is important as otherwise an empty configuration draft is displayed by the CDS and not the configuration draft that was transferred to the device connected during earlier configuration Once the configuration has been received you are prompted as to whether you want to change to a different user group You can only later transfer a new or changed configu ration draft if you change to the Authorised client user group Check identification of the devices Check to make sure that all devices in the project have been correctly identified Compare the devices connected with the data in the viewing area for the CDS You can save the projects in files and open them again later Only one project at any one time can be opened in the CDS If a project is open while opening or creating another pro ject the original project will be closed When you open an existing project or add a new project then you should connect the de vices displayed to the devices connected By connecting you will be able to verify that the connected devices and the devices shown in the project tree have matching type code You can also compare a project saved and or opened in the CDS with a saved project file In addition you can open a list showing the properties of a project or of a single device SICK AG Industrial
34. viewing area right of the CDS 13 Status bar with symbols for connected and configuration verified 13 Connection of the PC e g to a device from SICK AG Industrial Safety NL E E anti 16 Selecting the communication protocol essen 19 Status bar with check mark for configuration verified iii 20 Dialog box for the configuration wizard based on the example of the S 3000 15 in Lime tt Ui eget etude Pe iet e e ets 21 Dialog with file cards based on the example of the C 4000 22 Buttons for paging through the configuration protocol in 23 SICK AG Industrial Safety Systems Germany All rights reserved 8 009 241 N248 11 02 03 GB 12 02 TB 8 009 241 N248 11 02 03 RV Printed in Germany 04 03 Subject to change without prior notice Your contacts Australia Phone 61 3 94 97 4100 008 33 48 02 toll free Fax 61394971187 Austria Phone 43 2 23 66 22 88 0 Fax 43 223 66 22 88 5 Belgium Luxembourg Phone 32 24 66 55 66 Fax 32 24633104 Brazil Phone 55 11 55 61 26 83 Fax 5511 55354153 China Phone 8 52 27 63 69 66 Fax 852 27636311 Czech Republik Phone 42 02 578 10 561 Fax 4202 578 10 559 Denmark Phone 45 45 82 64 00 Fax 45 45826401 Finland Phone 3 58 9 728 8500 Fax 358 9 7288 5055 France Phone 33 1 64 62 35 00 Fax 33 1 64623577 Germany