Home
User Manual - the Connerton Company!
Contents
1. 00 Gas Manifold 13 00 500 00 Chrome Knob 40 150 00 Burner 14 00 275 01 Regulator Natural 40 675 00 Air Shutter 00 275 02 Regulator Propane 40 200 01 Orifice Hood Natural 15 00 495 02 Bullet Foot Round Leg 40 200 02 Orifice Hood Propane Seo Sey gt Condition Small no burner flame Small no pilot flame Yellow burner flame Flame lifts off burner Too hot cold Probable Cause Regulator failure Plugged orifice hood Plugged burner port Pilot valve setting Plugged pilot tip Improper air shutter setting Enlarged orifice hood Improper air shutter setting Plugged orifice hood Improper level setting Improper control setting Improper level setting TROUBLESHOOTING GUIDE Solution Unplug regulator vent hole or replace regulator Unplug hole or replace orifice Unplug burner port s Adjust flame height Unplug pilot ports Increase air shutter setting until flame is blue Replace w correct orifice Decrease air shutter setting until flame sits on burner Unplug orifice hole or replace orifice Adjust level w feet or shims Adjust control setting or replace control Adjust level w feet or shims LIMITED WARRANTY The Connerton Company warrants to the original user for a period of one year from date of installation not to exceed 18 months from date of shipment by Connerton that the equipment manufactured is free from defects in material or workmanship Our obligation under t
2. Installation O N B E RTO N Operation amp Maintenance Fine Cooking Equipment For Over 70 Years Instructions CSP SERIES STOCK POT STOVES For Your Safety Warning Do NOT store or use gasoline or Improper installation adjustment alteration service or other flammable vapors and liquids maintenance can cause property damage injury or death in the vicinity of this or any other Read the installation operation and maintenance instructions equipment thoroughly before installing or servicing this equipment To Purchaser After installation of your stove immediately contact your local gas supplier to obtain information in the event the user of your equipment smells gas This information must be posted in a prominent location To User RETAIN THIS MANUAL FOR FUTURE USE Upon receipt of this stove inspect it thoroughly for any damage which may have occurred during shipment If damage is observed contact the delivery agency immediately 1 Preparation For Installation Safe and satisfactory operation of the stove depends to a great extent upon it s proper installation It should be installed in accordance with the National Fuel Gas Code Z223 1 these instructions and applicable State and Local Codes Installation must be made by a licensed plumber Initial setup must be made by a licensed service company A gas pressure regulator is supplied with your stove The regulator must be installed before connecting stove to gas suppl
3. his warranty shall be limited to furnishing without charge any part of said product which upon examination by The Connerton Company shall prove to be defective Parts wear is not considered a defect The Connerton Company will not be responsible for labor or transportation charges incidental to the replacement of same The Connerton Company assumes no responsibility for failure of the equipment to operate properly due to improper installation or operation This warranty applies to all equipment that has been unaltered properly installed and maintained in accordance with national and local codes and in accordance with the installation and operating instructions included with this equipment This warranty does not extend to normal maintenance items including but not limited to air and gas adjustments and adjustments to pilot flames Proper installation adjustments and initial checkout is the responsibility of the dealer the owner user or installer and not that of The Connerton Company Please fill out and refer to the following when contacting the factory Purchase Date Model CSP 18 3 Serial Gas Type
4. o replace that removed through the exhaust hood 3 Gas Piping Make sure the gas pressure regulator supplied with the stove is installed correctly Connect outlet side of regulator to stove The regulator is set at 4 inches w c on natural gas and 11 inches w c on propane gas A 1 8 pressure tap is provided on the gas manifold at the front of the stove for checking the gas pressure Please note air vent on regulator can plug with grease thereby shutting gas supply off Install regulator in drip free area Connect stove to the gas supply line Under no circumstances should the gas supply line be smaller than the inlet pipe on the stove A gas shutoff valve must be installed in the gas supply line upstream of the stove for complete shutdown and service Use pipe sealant on all pipe joints Sealant must be resistant to the action of L P gasses For proper performance the stove must be level If legs are provided adjust feet at bottom of legs to level stove If legs are not provided seal the base of the stove to the countertop with silicone If the stove is supplied with casters the installation must be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances ANSI Z21 69 and a quick disconnect device that complies with the Standard for Quick Disconnect Devices for Use With Gas Fuel ANSI Z21 41 Adequate means must be provided to limit the movement of the stove without depending on the connector and the q
5. uick disconnect device or it s associated piping to limit the stove movement Restraining device should be connected to legs or back of body IMPORTANT Check all gas connections for leaks using a soap and water solution DO NOT USE AN OPEN FLAME FOR CHECKING PURPOSES 4 Lighting And Relighting Of Stove A Turn all burner valves and lighter valves to OFF Wait 5 minutes B Turn on lighter valves and light pilots Adjust flame height to approximately 1 2 C Turn on burner valves to operate your stove D For complete shutdown turn off all valves and the gas shutoff valve located upstream of the stove E To relight repeat above procedures 5 Care And Maintenance Contact factory factory representative or a local service company to perform maintenance and repairs Please Note Contact factory before any warranty repairs are made A To clean top grate use warm water a mild cleanser and wire brush B At least once per day clean and empty drip pan C Periodically but not less than once every 3 months clean burner orifices using warm water and wire brush Make sure equipment is cold before removing burners and orifices CSP STOCKPOT STOVE 40 100 00 Grate 9 40 350 01 Pilot w tubing inner ring 40 400 00 Body 10 40 350 02 Pilot w tubing outer ring 40 425 00 Front Panel 11 00 225 00 Pilot Valve 40 450 00 Grease Pan 12 00 250 00 Manual Control Valve 40 300
6. y line Please note air vent can plug with grease thereby shutting gas supply off Install regulator in a drip free area The stove and it s individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 45 kPa The stove must be isolated from the gas supply piping system by closing it s individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 kPa 2 Clearances And Ventilation This stove is designed for installation in non combustible locations with O inch clearance from sides and back The Connerton Company 1131 E Wakeham Avenue Santa Ana CA 92705 4145 Telephone 714 547 9218 Fax 714 547 1969 www connertoncompany com Keep equipment area free and clear from combustibles The area in front of and above the stove must be clear to avoid obstruction of flow of combustion and ventilation air Means must be provided for adequate air supply and adequate clearance for air openings into the combustion chamber Adequate clearances must be provided in front and sides of the stove for servicing and proper operation It is important that the stove be installed under an exhaust hood which is adequate to remove the products of combustion and cooking vapors Sufficient make up air must also be provided to the space where the stove is located t
Download Pdf Manuals
Related Search
Related Contents
Mise en page 1 Samsung MD32C User Manual PL - US ーXt デスク 取扱説明書 Page 1 Page 2 Page 3 現場における土の乾燥単位体積重量試縮方法 English técnicas de expresión gráfico plástica Sanyo PLC-XU21N User's Manual QB-78F1026 In-Circuit Emulator User`s Manual Reference Manual - B&H Photo Video Digital Cameras Copyright © All rights reserved.