Home

MEDIUM DUTY PAN/TILT UNIT

image

Contents

1. 4 2 Connection P T with outdoor housing eee ee AS COntTroOl WIPET penitent cata Portes ihe Ment nail EE Ube areola villa V SETTING PAN TILT END 51 ellie th Pa n TIMIS sy cog 08 232 ued ee Bee ae aT Wed 52 Setting the TILT Wiis ccc feos cea ied atta dese 3 ViInstallation eee ier ces west asst he ithe she E tas VIE SPECIFICATIONS ceinen nae a a I IMPORTANT SAFEGUARDS a This apparatus must be connected to Earth This installation should be made by made by a qualified installer b Do not carry out electrical installations in wet weather conditions c Voltage must to be matched with P T d Examining connection to sure that is correct e Please not to put the P T with auto scanning continuouly for long time II Summarize This unit is a hi tech CCTV product which incorporates panoramic speed variable PAN TILT multifunctional decoder CPU processor memory chip into a whole It can largely reduce connection and installation processes of components in the system rise up reliability of the system and facilitate installation and maintenance Therefore it has advantages of beautiful appearance compact structure and easy operation 1 Integrated Multi Protocol Decoder a With integrated decoder and multi protocol it can integrate 16 kinds of communication protocols in maximum As its baud rate of communication can be adjusted it is compatible with many normal systems by easy setup inside the dome camera so
2. D1 Figure 4 is Connect way of DI Figure 3 is come out line of air connector plug ay FED ACAV IN BAK BLACK ACAV IN CRANE RNE R485 VELON YELLOW RS485 VIDEO VIDEO VIDEO GUT Figure 3 2 Connection of P T and outdoor housing when collocate the special decoder for housing decoder s control signal input Power supply AC24V and video signal output by air waterproof connector plug D2 to conncet Figure 5 is connect way of D2 Note Connect P T s GND with lens decoder s GND Furthermore P T s TXD RXD must cross connect with lens decoder s TXD RXD Otherwise lens will not to be controlled Otherwise Could not to preset lens s position only just could preset P T s postision DI 1 ACAV IN X 1 AC2AV GUT 2 AC2AV IN 2 AC24V OUT 3 RS485 3 TL LA D A ON aoaneran 2 O za 5 R485 O O 5 ROT A 6V CEO 6VICEO ees 7 V DEO 7 V DEO Figure 4 Figure 5 3 Control wiper Use command D ZOOM ON to startup wiper Use command D ZOOM OFF to stop wiper Also could use call NO 64 preset position to startup or stop switch controll wiper V SETTING PAN TILT END a Setting the Pan limits see figure 6 Loosen the M4 screws and loosen the pan strikers Adjust the strikers until they are at the position to strike the relevant actuator thus activating the limit switches Tighten the M4 screws to secure the pan strikers b Setting the Tilt limits see f
3. MEDIUM DUTY PAN TILT UNIT V1 1 Please read the operation manual carefully before installing and using SAFETY PRECAUTIONS CAUTI CN TO REDUCE THE R K CG ELECTR CAL SHOOK DO DOT CPEN COVERS NO USER SERV CEABLE PARTS NS DE REFER SERV A NS TO QALI FI ED SERV PERSONNEL The lighting flash wth a arrowhead symbol in an equi l ateral triangle is intended to alert the user There is uninsul ated dangerous voltage presence near by the product s encl osure which nay be risk of to persons The excl aration point wthin an equilateral triangle is intended to alert the user to reference of the important operating and mai nt enance servicing instructions THE PRODUCT CODE MARKED CN THE BATOM COVER PLEASE FILL THE OCDE IN THE FOLLOWING BLANK PLEASE SAV NG TH S SPEC FI CATI ON CAREFLLLY SO THAT CHA NG ME PRODUCT COLE INDEX I IMPORTANT SAFEGUARDS 0 0 cece ence eee es Summa Ze ook Sates cg acannon a Agha eee aca a TT Setting of P T iscsi pak as ca Bohan be cea eae aes AVA AOR 3 1 Address setting of P T i iciGai ces ees o ete ets pesteetistie acs cauteentaates 3 2 Setting of terminal sTESIStAnCe i525 syns y a ednalsds Seige eeonsa cheese te 3 3 Setting of communication protocol ccc cece eee eee eee eee 3 ASCLUNE of bad TALE oo xcs dias eae e a a EARE E EEA IV CONNECTION DETAIES 2 iene ek i sea ees 4 1 Connection P T with controlleriiaicsiscsweicra vanenesiaadaeetelegs
4. N Table 2 means the 3 protocols are shown as follows NECN 9600Bps Na LOO D 2400Bps h P I PELCO P 4800Bps h f a A PELCO P 9600Bps h f i PANASON O 9600Bps Malili auaa AANDE ALEO 9600Bps WV halehel Ue U t r ak 9600Bos ANDNEIE 4 Setup of the Baud Rate of Communication As shown in Figure 1 SW2 is used to set the protocol of communication and the baud rate used by the dome camera DIP 6 and DIP 5 of SW2 are used to select the baud rate of communication and 4 different baud rates can be selected in maximum If the controller adopts non standard baud rate you can adjust it to be identical with that of the controller as per the following table ee Setup of Baud Rate Baud Rate of Communication pip pyp2 DIP3 Dip4 DIP DIP6 2400bps OFF OFF 4800bps ON OFF 9600bps OFF ON 19200bps ON ON IV CONNECTION DETAILS Table 3 Notice Before carrying out any electrical installation ensure that the cable being used in at the correct voltage and current rating for the application 256 Connector Plug amp Cable 7 pin Socket Rear Casing 1 Connection P T with controller Figure 2 RS485 control signal power supply AC24V video signal could connect with controller by air waterproof connector plug
5. elect switch of the 120Q terminal resistor on the bus RS485 on which only one terminal resistor of the dome camera at the farthest end can be connected while the terminal resistors of other devices should be opened 3 Setup of the Protocol and the Default Baud Rate As shown in Figure 1 SW2 is used to set the protocol of communication and the baud rate used by the dome camera DIP 4 to DIP 1 of SW2 is used to select protocols and 16 different protocols can be selected in maximum Following table shows states of coding switches of protocols selected by the dome camera in which e protocol has been integrated while o means the protocol is temporarily vacant Some protocols and the states of the coding switches of normal baud rate of these Selection of Protocols Normal Baud Rate Integrated Type of Protocols DIP1 DIP2 DIP3 DIP4 DIP5 DIP6 Protocol SAMSUNG ON OFF OFF OFF OFF ON NEON ON OFF OFF OFF OFF ON Reserved OFF ON OFF OFF OFF ON o PELCO D ON ON OFF OFF OFF OFF CO P 4800 OO a At ea ee on on PANASONIC ON OFF ON OFF OFF ON o Longcomity OFF ON ON OFF OFF ON HUNDA600 ON ON ON OFF OFF ON LILIN OFF OFF OFF ON ON OFF o VICON ON OFF OFF ON ON OFF o MOLYNX OFF ON OFF ON OFF ON o KALATEL ON ON OFF ON ON OFF o VCL OFF OFF ON ON OFF ON o DAIWA ON OFF ON ON OFF ON ALEC OFF ON ON ON OFF ON Ultrak ON ON ON ON OFF O
6. igure 7 Release the screw locks and adjust the strikers until they are at the position to strike the actuator thus activating the limit switches ADJUSTABLE STRIKER lt A ibA ww sS SCREW LOCK Figure 6 Figure 7 vi INSTALLATION a This outdoor Pan Tilt unit is intended to be mounted on a wall mount The unit base has 4 holes equi spaced on 4 101 6mm P C D see figure 8 which line up with the bracket mounting holes Mount the unit base onto the bracket using the four M6x25 Hex head screws 6mm washers and the M6 nuts provided in the packing kit b Remove the six M4mm fixing screws from the top platform using the three M1 4 20screws supplied Secure the Sub plate to the base of the Camera Housing see figure 1 Secure the sub plate with camera housing attached with the six 6mm fixing screws removed earlier A 98 Figure 8 VII SPECIFICATIONS Input Voltage AC 24V Angular Travel Pan 350 Tilt 20 90 OTT MOUNT Speed Pan 0 25 10 second Tilt 0 25 10 second Limit Stop Externally adjustable Load Rating 15Kgs OTT MOUNT Operating Temperature 35 C 60 C Construction Aluminum alloy casting Measurement 225 L x180 W x260 H OTT MOUNT Unit Weight 10 Kg
7. it has stronger versatility b RS485 serial control addresses of unit 1 511 2 Integrated Speed Variable PAN TILT a Turning 0 355 horizontally and an adjustable speed from 0 25 10 rad s turning 90 20 vertically with a speed up to 10 rad s b Running stably at low speed with super lower noise Pictures have no shaking 3 High Intelligent Degree a As much as 64 preset positions can be preset with powerless memory b The P T can scan horizontally between two points and scan speed can be modified c Six sets of programmable tour locus with 16 position each set The running speed and the detention time are adjustable respectively 4 Could to be cooprated with outdoor housing also could control camera that in housing a Camera s iris focus zoon could to be manual controlled b Control auto iris shutter speed c Auto white balance tracking Il P T SETUP 1 ADDRESS SET D P DO P9 Address Sl ect f 0 120Q terminal resistor is 120Q terminal resistor is open it and change the ID CODE connected on R485 Bus op 3 R S D g Qo oa o n Figure As shown in Figure 1 SW1 is used to set address of the P T from 1 511 The ID CODE from DIP 9 to DIP 1 are equivalent to a 9 bit binary digit DIP 9 is MSB while DIP 1 is LSB The state ON of each bit means 1 while OFF means 0 Following table shows states of coding switche
8. s of some addresses For Example P T Status of ID CODE Address DIP1 DIP2 DIP3 DIP4 DIPS DIP6 DIP7 DIPS DIP9 1 ON OFF OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF OFF 5 ON OFF ON OFF OFF OFF OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF OFF OFF 7 ON ON ON OFF OFF OFF OFF OFF OFF 8 OFF OFF OFF ON OFF OFF OFF OFF OFF 9 ON OFF OFF ON OFF OFF OFF OFF OFF 10 OFF ON OFF ON OFF OFF OFF OFF OFF 11 ON ON OFF ON OFF OFF OFF OFF OFF 12 OFF OFF ON ON OFF OFF OFF OFF OFF 13 ON OFF ON ON OFF OFF OFF OFF OFF 14 OFF ON ON ON OFF OFF OFF OFF OFF 15 ON ON ON ON OFF OFF OFF OFF OFF 16 OFF OFF OFF OFF ON OFF OFF OFF OFF 17 ON OFF OFF OFF ON OFF OFF OFF OFF 18 OFF ON OFF OFF ON OFF OFF OFF OFF 511 ON ON ON ON ON ON ON ON ON Table 1 TELT 6 7 8 9 10 P T Addr ess 4 2 Selection of the Terminal Resistor P T Addr ess 511 As shown in Figure 1 DIP10 of the ID CODE is the s