1. 6 U UUUUUUUUUUUUUUI S t E ee ee MS CA TT TT EAA a cok a I CORA S orate se a oe Ei z erza O _O_ The 6KQE 2GSFP 2 port Fiber Gigabit module provides two SFP open transceiver locations that can operate at 10 100 1000Mbps speeds Transceivers are www GarrettCom com s s lt 35 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 available with both multi mode 850nm 550m 1310nm 3km single mode 1310nm 10km and 25km and single mode 1550nm 40km and 70km fiber options see page 5 of this manual for part numbers The 1000Mb Gigabit SFP fiber port modules on the Magnum 6KQE are normally set factory default to operate at AUTO mode for best fiber distance and performance LEDs are configured the same as the copper gigabit option see Section 5 1 12 above 6 AVRORCRSRCRVRORORORCRORCRORURURORU PS SR URURURURURORURORURURO Asooas CEEE REEE SSeS Seas oessa Oll eeo o JIQ B SaaS es LO The 6KQE 1GSFP 1 port Fiber Gigabit module provides one SFP open transceiver location that can operate at 10 100 1000Mbps speeds 5 2 6K
2. 5 1 6 6KQE4 3MMRJ 3 x MTRJ 1 x RJ45 Slot A Slot C O SRURURURORURURURURORURUMURURE 6 LJ YUUU UU UU UU Taunt Punt TT E i j C AoA SoS eee ey Om _O The 6KQE4 3MMRJ 4 port Fiber Copper module provides three 100Mb Multimode MTRJ Fiber ports and one 10 100Mb switched RJ 45 port This module option occupies parts of Slot A and Slot C see also Section 5 1 4 for information 32 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 5 1 7 6KQE4 1MLC 1x LC 3 x RJ45 Slot C LIU cor ae gae a eop ap a MMG CO C TT C C EN goose PA rie ae arn lar E AA ee eee ae fo O JO par LO i The 6KQE4 1MLC 4 port Fiber Copper module provides one 100Mb Multimode LC Fiber port and three 10 100Mb switched RJ 45 ports The 6KQE4 1MLC fiber port is a Small Form Factor SFF LC Multimode connector used primarily in 100Mbps fiber to the desktop links When installed in a Magnum 6KQE Series Switch it supports fiber optic cable distances up to the IEEE standard 100Mbps distance limits i e typically 2km at ful
3. 250VDC Power Input nominal range 160 to 300VDC Std Terminal Block GND _www GarettCom con sass 2 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 AC Power Supply Internal AC Power Connector IEC type male recessed 100 240VAC Power Input 47 to 63 Hz auto ranging Power Consumption 20 watts Max for a fully loaded fiber model with 2Gb 15 watts Max for 8 port copper and 100Mb fiber model Dual DC Power Input Optional A Dual Source option is available for the 12VDC 24VDC 48VDC and 125VDC and 250VDC models This provides for continuity of operation when either of the DC input sources is interrupted See Appendices B and C The Dual Source Terminal Block is marked A A B B 6KQE Mounting Vertical mounting normal Suitable for wall or DIN Rail mounting 6KQE Agency Approvals and Standards Compliance UL listed UL60950 cUL CE Emissions meet FCC Part 15 Class A NEBS Level 3 and ETSI Compliant IEEE 1613 Class 2 Environmental Standard for Electric Power Substations See also Note for Power Substations in Section 3 2 1 3 6 1 and 5 1 3 IEC 61850 EMC and Operating Conditions Class C for Power Substations NEMA TS 2 and TEES for DC powered and PoE powered traffic control equipment Class Division 2 and ATEX for hazardous locations pending Warranty Three years per UL 60950 temperature rating Made in USA See the Configuration Guide on the GCI web site at htt
4. Full Dx OFF Half Dx 2 ON Link 3 BLINKING Activity 4 ON 1000Mb Not used for Fiber 5 ON 100Mb Not used for Fiber 6 ON 10Mb Not used for Fiber WN gt Ons 29 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 5 1 2 6KQE Base Unit LED designations GarrettCom Magnum 6KQE GarrettCom Managed Edge Switch G6KQE z D 3 E 3 a A 2 m Managed Edge Switch youMsg pg pebeuew 6KQE Base Unit Top label 5 1 3 6KQE4 RJ45 4x 10 100Mb RJ45 Slot C JRURURURURU ROMO RORURURORURORUMORORG WAPI Fama fom Foam on SGaaaasS The 6KQE4 RJ45 4 port Copper module provides four 10 100Mb switched RJ 45 ports The 10 100Mb switched ports normally as a default setting are independently N way auto negotiating and auto crossover MDIX for operation at 10 or 100Mb speed in full or half duplex mode i e each independently selects a mode and speed to match the device at the other end of the twisted pair cable www GarrettCom com sss 30 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 for auto negotiation and MDIX details see Section 4 2 in the 6KQE User G
5. by side CCTV Camera ry CCTV Camera gt d j CCTV Camera Fig 2 5c Magnum 6KQE deployed in a video security CCTV application for monitoring and securing the premises 15 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 3 0 INSTALLATION Before installing the equipment it is necessary to take the following precautions 1 If the equipment is mounted in an enclosed or multiple rack assembly the steady state long term environmental temperature around the equipment must be less than or equal to 60 C 2 If the equipment is mounted in an enclosed or multiple rack assembly adequate airflow must be maintained for proper and safe operation 3 If the equipment is mounted in an enclosed or multiple rack system placement of the equipment must not overload or load unevenly the rack system 4 If the equipment is mounted in an enclosed or multiple rack assembly verify the equipment s power requirements to prevent overloading of the building s electrical circuits 5 If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and uncompromised earthing path This section describes installation of the Magnum 6KQE Switches as well as connection of the various Ethernet media types 3 1 Locating Magnum 6KQE Switches For vertical panel mounting and wall mounting see Section 3 3 For vertical DIN Rail mounting see Section 3 3 1 For DC power
6. input data see Appendix B For Dual Source see Appendix C The rugged metal case of the Magnum 6KQE will normally protect it from accidental damage in a lab or workplace setting Maintain an open view of the front to visually monitor the status LEDs Keep an open area around the unit so that cooling can occur from convection while the unit is in operation The 6KQE has no fans so it is silent when in operation Internal electronics use the case as a heat sink so the unit may normally be quite warm to the touch 16 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 3 2 Connecting Ethernet Media The Magnum 6KQE Switches are specifically designed to support standard Ethernet media types within a single Switch unit This is accomplished by using a two popular Fiber Connectors which can be individually selected and configured See Section 5 1 for a description of the Modules The various media types supported along with the corresponding IEEE 802 3 802 3D 802 3u 802 3AB and 802 3z standards and connector types are as follows Media IEEE Standard Connector Twisted Pair CAT 3 or 5 10BASE T RJ 45 Twisted Pair CAT 5 100BASE TX RJ 45 Twisted pair CATSE or CAT6 1000BASE T RJ 45 Fiber Multi mode 100BASE FX MTRJ LC Fiber Single mode 100BASE FX LC Fiber Multi mode 1000BASE SX LC SFP Fiber Multi mode Single mode 1000BASE LX LC SFP Fiber Single mode 1000BASE ZX LC SFP See http www garrettcom com techsuppor
7. is not an auto negotiating device the 6KQE s RJ 45 ports will try to detect its idle signal to determine 10 or 100 speed and will default to half duplex at that speed per the IEEE standard General information Auto negotiation per port for 802 3u compliant switches occurs when the devices at both ends of the cable are capable of operation at either 10Mb or 100Mb speed and or in full or half duplex mode and can send receive auto negotiation pulses and www GarrettCom com 26 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 the second of the two connected devices is powered up i e when LINK is established for a port or the LINK is re established on a port after being lost temporarily e NOTE Some NIC cards only auto negotiate when the computer system that they are in is powered These are exceptions to the negotiate at LINK enabled rule above but may be occasionally encountered When operating in 100Mb half duplex mode cable distances and hop counts may be limited within that collision domain The Path Delay Value PDV bit times must account for all devices and cable lengths within that domain For Magnum 6KQE Fast Ethernet switched ports operating at 1OOMb half duplex the bit time delay is 50BT 4 3 Flow control IEEE 802 3x standard Magnum 6KQE Switches incorporate a flow control mechanism for Full Duplex mode The purpose of flow control is to reduce the risk of data los
8. legacy and advance network needs The modularity of the 6KQE Managed Edge Switches make them an attractive choice for use in applications with LAN connections to an organization s multiple site offices and factory floors The different locations can be easily connected together with the Fiber ports supported by the Magnum 6KQE Switch A main NT server in a secure area protected from earthquake or fire hazards can be connected to the full duplex Gigabit Fiber port Magnum 6K32 SNMP Monitor Fiber connection other building Factory Floor PLC Factory Floor PLC Factory Flaor PLC Fig 2 5a The industrial factory floor application with Magnum 6KQE 13 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 Extended temperature ratings and a variety of options for AC DC power supplies qualify this managed 6KQE switch for use in non temperature controlled networks and many other temperature sensitive critical Industrial applications where above normal room temperatures occur while the network is in operation Full duplex future proof fiber media can easily connect long distance subnets and provide a stable secure network to all applications The SNMP management capability of the Magnum 6KQE Switch helps create a database of all the network subnets to easily manage the network Example 2 A managed network is needed to provide a redundant ring topology for maximum redundancy In a network where any faulty c
9. sas 12 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 Example 1 Magnum 6KQE Switch for an Industrial Application Equipped with lots of useful features including hardened enclosures a wide spread of DC power supply options and extended temperature ratings qualifies the Magnum 6KQE Managed switch for any Industrial factory floor traffic control transportation system or power utility application The several MNS 6K software operated features qualifies this managed switch to operate and perform securely and reliably in all critical applications The addition of S Ring and the Link Loss Learn software features allow this Managed switch to provide a very secure highly available redundant network capability in any ring topology network The Managed 6KQE s modularity along with the MNS 6K management software features remarkably handle industrial environments i e where the factory floors are networked with Ethernet based mixed media LANs equipped with PLCs computers for taking readings and data from Machines Client Server databases etc and sending these important data to the central office data warehouses very securely and reliably The DIN Rail Mounting options on the Magnum 6KQE allow the factory floor s industrial user to mount the 6KQE securely anywhere on their Network setup The option of setting the ports at 10 or 1OOMb on copper and 100Mb on fiber media provide widespread options to the users to mix and match their
10. so the 48VDC power input source to the Magnum 6KQE must be strong enough to provide power to the 6K switch and to all 4 RJ 45 ports with PD devices connected up to 15 watts per PoE port _ www GarrettCom com ss 36 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 e Inthe case where the 48 VDC power in not internally connected to the POE port pins and no power is coming to the PoE ports for some reason all the PoE port LEDs are ON simultaneously to indicate a trouble condition The ports will still operate properly for data traffic to non PoE devices 6 0 TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments The installation of a Magnum 6KQE Switch is a straight forward procedure The operation is also straightforward and is discussed in Section 4 0 of this 6KQE User Guide Should problems develop during installation or operation this section is intended to help locate identify and correct these types of problems Please follow the suggestions listed below prior to contacting your supplier However if you are unsure of the procedures described in this section or if the Magnum 6KQE Switch is not performing as expected do not attempt to repair the unit instead contact your supplier for assistance or contact GarrettCom Customer Support 6 1 Before Calling for Assistance 1 If difficulty is encountered when installing or operatin
11. 100BASE FX Fiber Port LC type plug in SFF Fiber multi mode 1OOBASE FX Fiber Port OOOBASE SX SFP modules Fiber Single mode connector types Fiber Port LC type Fiber SFF single mode 100BASE FX Fiber Port OOOBASE LX SFP modules LEDs Per Port one set at the port one set on swivel top on right side see section 5 1 1 and 5 1 2 for detailed LED configurations Operating Environment Ambient Temperature 40 to 140 F 40 to 60 C for UL60950 and Component Parts rating 40 to 195 F 40 to 85 C for IEC 60068 Type Test short term rating Storage Temperature 60 to 210 F 50 to 100 C Ambient Relative Humidity 5 to 95 non condensing Altitude 200 to 13 000 ft 60 to 4000m Conformal Coating humidity protection optional Request quote Alarm Relay Contacts One NC indicating internal power one NC software controllable Packaging Enclosure High strength extruded aluminum Dimensions 6 85 in Hx 7 5 in W x 2 0 in D 17 4 cm H x 19 1 cm W x 5 08 cm D Cooling method Convection fully enclosed ribbed surface aluminum case used as a sink designed for vertical mounting no fans Weight 3 Ibs 1 3 kg Management Console connector Serial DB 9 see details at sec 3 6 DC Power Supply Internal floating ground design 12VDC Power Input nominal range 8 to 18VDC 24VDC Power Input nominal range 18 to 36VDC 48VDC Power Input nominal range 36 to 60VDC 125VDC Power Input nominal range 88 to 150VDC
12. 4VDC Power Input nominal range 18 to 36VDC 48VDC Power Input nominal range 36 to 60VDC 125VDC Power Input nominal range 88 to 150VDC 250VDC Power Input nominal range 160 to 300VDC Standard 6KQE DC Power Input Terminal Block GND See also Section 1 0 Technical Specifications for the 6KQE base unit B2 0 12 24 48 125 and 250VDC POWER THEORY OF OPERATION The 12 24 48VDC 125 and 250VDC power options are designed using diodes inside i on each DC power input line behind the two external power connection terminals so that the power from an external source can GND GND only flow into the hub This allows the Switch to operate only whenever DC power is correctly applied to the two inputs It protects the Switch from incorrect DC input connections An incorrect polarity POWER SWITCH SWITCH SUPPLY 40 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 connection for example will neither affect the Switch its internal power supply nor will it blow the fuse in the internal power supply B3 0 APPLICATIONS FOR DC POWERED ETHERNET SWITCHES Magnum 6KQE Switches are easily installed in a variety of applications where 12 24 48VDC 125 and 250VDC power is used as the primary power source The DC power configuration capability provides an Ethernet networking solution utilizing a special power supply in switches with a proven track record The 48 VDC solution is particularly u
13. 6 x 4 69 inches center to center 3 3 1 DIN Rail Mounting the Magnum 6KQE The Magnum 6KQE is designed for use in a factory floor industrial environment It is available with an optional DIN Rail bracket to mount it securely in a metal factory floor enclosure maintained vertically for proper convection cooling of the unit The Magnum 6KQE requires one DIN Rail bracket for secure mounting This may be ordered as Model DIN RAIL 6KQ See a 6KQE viewed from the side at the rear with model DIN RAIL 6KQ in place on the unit The DIN Rail bracket is mounted on one of three available positions at the rear of the 6KQE unit Eight threaded holes are provided on the rear of 6KQE for DIN Rail mounting purposes The required four screws are included with the DIN Rail bracket and are no 4 40 X 5 16 PHIL PAN Head To install the 6KQE with the DIN Rail bracket installed hold the 6KQE in the side 21 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 vertical position with the bottom out and with the top moved in toward the DIN Rail Position the DIN bracket over the top of the DIN Rail Then snap the bracket into holding position by moving the bottom of the 6KQE inwards to a vertical position The DIN Rail bracket is heavy duty and will hold the 6KQE securely in position even with cabling attached to the unit To release the 6KQE from the DIN Rail mounting press the top of the DIN Rail bracket slide DOWN to re
14. 9071 Fax 510 438 9072 Website http www GarrettCom com Email support garrettcom com Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 Federal Communications Commission Radio Frequency Interference Statement This equipment generates uses and can radiate frequency energy and if not installed and used properly in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at their own expense will be required to take whatever measures may be required to correct the interference Canadian Emissions Statement This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil respecte toutes les exigences du R glement sur le mat riel du Canada Cet appareil est Classe A Electrical Safety requirements 1 This product is to be installed Only in Restricted Access Areas Dedicated Equipment Rooms Electrical Closets or the like 2 48VDC products shall be installed with a readily accessible disconnect device in the building installation
15. QEP 48VDC Base Unit w PoE Power pass through The 6KQE is available with the option of having PoE capabilities on the four fixed RJ45 ports in the base unit ports 1 2 3 and 4 The PoE Power over Ethernet RJ 45 ports are similar to regular RJ 45 ports except they have the capability of providing power on each port to power up attached PD devices per the IEEE802 3af PoE standard The power pass through PoE ports are dependent upon the 48VDC input power to supply the PD power for these RJ 45 10 100 ports Each port supplies up to 15watts to power attached PoE PD devices The LEDs on the PoE ports are slightly different compared to regular non PoE RJ 45 ports When the PoE port is in use the PoE LED is ON when connected properly to an IEEE 803 af compliant PD device on that port When non PoE devices are connected the PoE LED is OFF Operation of Ethernet data traffic is not affected by PoE LINK and ACTIVITY LEDS are combined on the PoE modules into one LED that is marked as LINK ACT PoE LEDs Summary e For PoE devices each RJ 45 PoE port supports only 802 3af complaint devices The PoE LED is ON when the attached PD is drawing power from the port The power is supplied on the data pairs per IEEE802 3af PoE standard e For non PoE devices connected the PoE port will act as a normal RJ 45 port and the PoE LED is OFF No power is sent out from the port e The PoE ports in Magnum 6K s with 48VDC power input act as a pass through
16. SA ensuring compatibility with a wide range of networking kit see Section 1 2 for the SFP s available for the 6KQE Note It is highly recommended to remove the fiber cable first before removing the SFP transceiver for any reason Not removing the fiber cable first can damage the fiber cable cable connector or optical interfaces It is advised not to remove and insert a SFP transceiver frequently as this may shorten its useful life Note Always use an ESD wrist strap while handling the SFP transceivers since the SFP modules are static sensitive devices Note The copper 1000BASE T SFP transceiver port supports 1000Mb only It is recommended to use a straight through RJ 45 4 twisted pair connection while connecting to any Server workstation While connecting with any Switch repeater or other device it is recommended to use Crossover RJ 45 4 twisted pair category 5 or higher cabling The maximum length supported on copper 1O00BASE T is 100m 328 ft 3 2 5 Connecting Fiber Optic Cable to SFP Transceivers 1 Before connecting the fiber optic cable remove the protective dust caps from the tips of the connectors on the PM Save these dust caps for future use 2 Wipe clean the ends of the dual connectors with a soft cloth or lint free lens tissue dampened in alcohol Make certain the connectors are clean before connecting Note One strand of the duplex fiber optic cable is coded using color bands at regular intervals you
17. able cable disconnection or power failure can bring the whole thing down a ring switch can be reconfigured and up and running in milliseconds The ring topology of the network consists of high speed LAN segments supported by 100Mbps full duplex future proof fiber media to provide a secure long distance LAN connection The entire network is sharing a higher bandwidth Gigabit enabled data mining server for the vital database located in a separate secured building The copper ports are required for multiple subnets inside the power plant to check the status of other Ethernet units The entire spread network will be manageable to provide easy detectable uninterrupted support through a viewable SNMP monitor Magnum 6K32 SNMP Monitor Fig 2 55 Magnum 6KQE equipped with S Ring in redundant ring solution The Magnum 6KQE Managed Edge Switch equipped with a mix of copper and fiber ports provides an economical and seamless solution to many requirements The user configurable Magnum 6KQE provides an extra boost to the network requirements by providing copper fiber media along with the higher bandwidth support of 10 100 and 1000Mb The user can utilize the SNMP feature equipped with VLAN RMON STP and _www GarrettCom con sas 14 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 other standard managed LAN features to provide a secure and stable network The 6KQE Managed Fiber with S ring and Link Loss Learn features easily fulf
18. any earlier MNS 6K versions will not support the 6KQE hardware For additional information about MNS 6K see the Magnum MNS 6K Software User guide in pdf format a separate document normally accessible via your web browser at ftp ftp garrettcom com or FTP client program at ftp GarrettCom com using user m6kuser password m6kuser All MNS 6K software information and the documentation related to MNS 6K and MNS 6K SECURE software can be accessed at GarrettCom s FTP site Alternatively for the latest documentation and information or needed GarrettCom s MIBs for SNMP visit www GarrettCom com techsupport index htm software and look for the Magnum MNS 6K info For interactive training software which shows basic and advanced info about the Magnum MNS 6K management software and for a useful tool for first time users visit Magnum MNS 6K Operator Training You may also email info GarrettCom com for further information 10 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 2 4 Features and Benefits Managed switching for high performance Ethernet LANs Magnum 6KQE Switches provide unicast non blocking all ports can run at full speed at once performance with standard Managed Network Software They are typically used in LAN traffic centers with up to 8 100Mb 2 Gigabit ports for backbone connections where managed network services are desired Switching services includes 802 1p QoS packet prioritiza
19. at when used appears to create the problem _www GarettCom con ss 37 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 2 An accurate list of GarrettCom product model s involved with serial number s Include the date s that you purchased the products from your supplier 3 It is useful to include other network equipment models and related hardware including personal computers workstations terminals and printers plus the various network media types being used 4 A record of changes that have been made to your network configuration prior to the occurrence of the problem Any changes to system administration procedures should all be noted in this record 6 3 Return Material Authorization RMA Procedure All returns for repair must be accompanied by a Return Material Authorization RMA number To obtain an RMA number please use this URL https rma garrettcom com rma rma_request_noaccount php to fill out the form Please have the following information readily available Name and phone number of your contact person Name of your company institution Your shipping address Product name Serial Number or Invoice Number Packing List Number or Sales Order Number Date of installation Failure symptoms including a full description of the problem GarrettCom will carefully test and evaluate all returned products will repair products that are under warranty at no charge and will return the warranty r
20. at either may be grounded by the user if desired The chassis is earth or ground GND The connection procedure is straightforward Simply insert the DC leads to the Switch s power terminals positive and negative screws The use of Ground GND connects to the Switch chassis screw provided under the DC terminal Ensure that each lead is securely tightened NOTE Always use a voltmeter to measure the voltage of the incoming power supply and figure out the ve potential lead or ve potential lead The more ve potential lead will connect to the post labeled ve and the rest to the ve The GND can be hooked up at the last 41 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 When power is applied the green PWR LED will illuminate Note The GND should be hooked up first The 6KQE unit has a floating ground so the user may elect to Ground either or terminal to suit the customer s use Before connecting live power lines to the Terminal Block of 48VDC 12VDC 24VDC 125VD or 250VDC products always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more ve potential The more ve voltage lead from 48V or 48V supply must be connected to the post labeled B4 1 UL Requirements for DC powered units CAUTION 48VDC products shall be installed with a readily accessible disconnect device in the building installation supply ci
21. ation and User Guide 02 09 4 4 Power Budget Calculations for 6KQE Modules with Fiber Media Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget To calculate the power budget of different fiber media installations using Magnum products the following equations should be used OPB Optical Power Budget P min Pp min where Pr Transmitter Output Power and Pg Receiver Sensitivity Worst case OPB OPB 1dB for LED aging 1dB for insertion loss Worst case distance Worst case OPB in dB Cable Loss in dB Km where the Cable Loss for 62 5 125 and 50 125um M m is 2 8 dB km and the Cable Loss for 100 140 Multi mode is 3 3 dB km and the Cable Loss for 9 125 Single mode is 0 5 dB km and the Cable Loss for 9 125 Single mode is 0 4 dB km LX25 and the Cable Loss for 9 125 Single mode is 0 25 dB km ZX40 and the Cable Loss for 9 125 Single mode is 0 2 dB km ZX70 See http www garrettcom com techsupport power_budget pdf for more information on Power budget calculations 5 0 Magnum 6KQE Managed Edge Switch Port Modules This chapter describes each Port Module PM including appearance functionality and status displays 5 1 6KQE Modules An important feature of the Magnum 6KQE is the use of Port Modules for flexible mixed media connectivity to RJ 45 copper and various fiber media The first four ports 1 2 3 amp 4 of the Magnu
22. b chassis screw Input Two separate sources each at 8 18 VDC Power Supply Internal 24VDC Dual Source model Dual Src 24V DC Power Connector First Source A A 2nd Source B B GND ground wire connection to the hub chassis screw Input Two separate sources each at 18 36 VDC Power Supply Internal 125VDC Dual Source model Dual Sre 125V DC Power Connector First Source A A 2nd Source B B GND ground wire connection to the hub chassis screw Input Two separate sources each at 88 150 VDC Power Supply Internal 250VDC Dual Source model Dual Sre 250V DC Power Connector First Source A A 2nd Source B B GND ground wire connection to the hub chassis screw Input Two separate sources each at 160 300 VDC With the exception of the dual DC input power connections and the power supply all specifications and configuration options for the Magnum 6KQE 48VDC 12VDC 24VDC 125VDC and 250VDC models with this Dual Source option are identical to those listed in the Magnum 6KQE Edge Switches Installation and User Guide including Appendix B Internal DC Power Supply Option C2 0 MAGNUM 6KQE with DC Dual Source option The 6KQE Switch models with the internal 48VDC 12VDC 24VDC 125VDC and 250VDC Dual Source power supply are designed for installations where a battery plant is the power source and where two separate power sources are utilized in order to
23. cally 2km at full duplex and 412m at half duplex Each port has an Activity ACT LED indicating packets being received and a Link LK LED that indicates proper connectivity with the remote device when lit The 6KQE4 1MMRJ copper ports support Ethernet twisted pair segments of any standard length It is equipped with a three port RJ 45 connector and offers 10 100 full half duplex auto negotiating capability on each port The RJ 45 connector is shielded to minimize emissions and will allow both unshielded twisted pair UTP and shielded twisted pair STP cable connections When installed in a Magnum 6KQE Series Managed Switch the copper ports support the standard distance of 100m on each port 5 15 6KQE4 2MMRJ 2 x MTRJ 2 x RJ45 Slot C 6 AVRURCRCRCRVEURORORCRORURORURCRORG S WA Nnn TnS ntn nT Taunt fa Pa fat a a ae L c NINN all coooa Saray SS SaaS ss The 6KQE4 2MMRJ 4 port Fiber Copper module provides two 100Mb Multimode MTRJ Fiber ports and two 10 100Mb switched RJ 45 ports see also Section 5 1 4 for additional information
24. contacts to which the user can attach two sets of status monitoring wires at the green terminal block When this option is present the terminal block for Alarm Contacts is part of the Power Input panel in the 6KQE case The DC power input connection is in the same panel The first NC Alarm Contact top position switch vertically mounted is a Software Alarm operated by user settings in the MNS 6K software The user can disable the Software Alarm feature with a software configuration command if desired When the Software Alarm is enabled the Form C Normally Closed NC contact is held close during normal software operation A user defined software malfunction such as an SNMP Trap or a Software Security violation or an S Ring Fault causes the contact to open and thus triggers an alarm in the user s monitoring system The second NC Alarm Contact is held closed when there is power on the main board inside of the Switch This provides a Hardware Alarm because the NC contacts will open when internal power is lost either from an external power down condition or by the failure of the power supply inside of the Magnum Switch Useful info about Alarm contacts 1 There are four terminal blocks 1 2 3 4 provided next to the DC power supply 2 The left two pins 1 2 are hardware operated 3 The right two pins 3 4 are software operated 4 These are both NC normally closed relays 5 The switch s software operation needs to be enable
25. d please use the original shipping container if possible Refer to Section 6 Troubleshooting for specific return procedures Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 2 2 Product Description Magnum 6KQE Managed Edge Switch Magnum 6KQE Managed Edge Switches provide configurability in an entry level industrial grade package The high performance 6KQE base unit comes with four 10 100 copper ports which may be either regular or PoE Up to 3 100Mb fiber ports or up to four more 10 100 copper ports or combinations may also be configured In addition one or two Gb ports may be configured as 10 100 1000 copper or SFP fiber in any 6KQE base unit Magnum 6KQE comes with the best of breed MNS 6K managed networks software MNS 6K SECURE optional See the Managed Networks Software MNS 6K datasheet for more information at http www garrettcom com techsupport software datasheets mns6kds pdf Magnum 6KQEs are ideal for building a switched hardened Ethernet network infrastructure connecting edge devices such as PLCs and IEDs with upstream switches or routers Designed for use in industrial applications such as factory floors and control cabinets industrial video surveillance systems with PoE power utility substations tariffed carrier field facilities or transportation and oil and gas the rugged Magnum 6KQE handles stressful workloads mixes of bursty data traffic and priority streaming traffic as well as hars
26. d and set to get the Alarm traps For detailed information about the Software Alarm and software control of SNMP alarm traps please reference the Magnum MNS 6K Software User Manual The Alarm Contacts are on the front left area next to the DC power source of the Magnum 6KQE unit and are green in color as shown in the picture Fig 3 5a Alarm Contacts 1 2 are hardware operated 3 4 are software operated 23 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 3 6 Connecting the Console Terminal to Magnum 6KQE Use a DB 9 null modem cable to connect the Magnum 6KQE Console Port the RS 232 port on the 6KQE Switch to your PC so that your PC becomes the 6KQE Console Terminal Note The DB 9 cable is not included with the 6KQE package Note For a detailed description of Managed Network Software MNS 6K and Magnum 6KQE Switch configuration for Network Management please refer to Magnum 6K Software Manual available on GarrettCom s FTP site Also available on GCI website at http www garrettcom com techsupport sw_downloads htm 3 6 1 RS 232 DB 9 Console port Serial port pin assignments Pin 1 Pin 5 DB 9 Console port connector Pin Signal Description 1 DCD Data Carrier detect not used 2 RXD Receive Data input 3 TXD Transmit Data output 4 open not used 5 GND Signal Ground 6 open not used 7 RTS Request to Send 8 CTS Clear to Send 9 open not used The above provided infor
27. d for POE powered applications such as IP video surveillance and 125V or 250V for substations An internal AC power supply may also be chosen universal AC for use worldwide Heavy duty design for Industrial Ethernet and extended temperature operation Fiber ports take more power than copper ports but the Magnum 6KQE design provides for this with heavy duty components The ambient temperature dual rating is 60 C per UL methods and 95 C per IEC type test methods MNS 6K licensed Management Software Managed Networks Software MNS basic version combined with a Magnum 6K Series Switch provides power and efficiency in a managed Ethernet platform A full range of industry standard software functions in the MNS 6K software product enables the versatile Magnum 6K Switches to perform efficiently in a wide range of managed LAN applications including redundant topologies MNS 6K SECURE optional for extra security Magnum MNS 6K SECURE software is designed for those customers demanding extra security in their networks MNS 6K SECURE is an optional item licensed per switch All of the features in regular MNS 6K are included plus extra security 11 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 E S Ring and Link Loss Learn for economical high availability using ring topology S Ring combined with the Link Loss Learn feature provides reliable fast recovery of a fault in an economical ring topology combining unmanaged and mana
28. e RJ 45 connector of the port Note that even though the connector is shielded either unshielded or shielded cables and wiring may be used 2 Connect the other end of the cable to the corresponding device 3 Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established 3 2 3 Connecting Single Mode Fiber Optic When using single mode fiber cable be sure to use single mode fiber port connectors Single mode fiber cable has a smaller diameter than multi mode fiber cable 9 125 microns for single mode 50 125 or 62 5 125 microns for multi mode where xx xx are the diameters of the core and the core plus the cladding respectively Single mode fiber allows full bandwidth at longer distances about 70km with the single mode LC 18 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 3 2 4 Gigabit SFP Small Form factor Pluggable Transceivers The small form factor pluggable SFP is a compact optical transceiver used in optical communications for both telecommunication and data communications applications Due to its compact hot pluggable characteristics SFPs are becoming a very popular choice for various applications The small chassis Magnum 6KQE is designed for industry standard Gb SFPs for user selection of the SFP gigabit media type as desired All SFPs used in Magnum 6KQEs are compliant with the industry standard Multi Source Agreement M
29. earning so as nodes are added removed or moved from one segment to another the 6KQE Switch automatically keeps up with node locations An address aging algorithm causes least used addresses to fall out in favor for frequently used addresses To reset the address buffer cycle power down and up _www GarettCom con ss 25 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 4 2 Auto Cross MDIX and Auto negotiation for RJ 45 ports The RJ 45 ports independently support auto cross MDI or MDIX in auto negotiation mode and will work properly with all the other connected devices with RJ 45 ports whether they support Auto negotiation e g 10Mb Hub media converter or fixed mode at 10Mb or 100Mb Half Full Duplex managed switch or not No cross over cable is required while using the 6KQE s copper port to other devices Operation is according to the IEEE 802 3u standard The Managed 6KQE s Fast Ethernet copper ports can be set for either fixed 100Mb speed or for 10 100 F H N way auto negotiation per the IEEE802 3u standard The selection is made via MNS software The factory default setting is for auto negotiation At 10Mb or 100Mb fixed speed the user may select half or full duplex mode by MNS Software for each RJ 45 port separately For detail information See Section 2 3 of this manual for information to access the 6K MNS Software user guide One frequently used application for the Managed Magnum 6KQE Switch copper ports
30. eceesssseceeeeeseees 27 4 4 Power Budget Calculations for 6KQE Modules with Fiber Media 28 5 0 Magnum 6KQE Managed Edge Switch Port Modules 0000 28 5 1 OKQE Modules eee eeeeecseseccseeseceseeceeseceeeseceeeeecaeeecsaecateeeeneseneeaeeees 28 5 1 1 6KQE Module LED designations 00 ieee eee cee ceeeereeeeeeee 29 5 1 2 6KQE Base Unit LED designations 30 5 1 3 6KQE4 RJ45 4x 10 100Mb RJ45 Slot C nece 30 5 1 4 6KQE4 IMMRJ 1 x MTRJ 3 x RJ45 Slot C 31 5 1 5 6KQE4 2MMRJ 2 x MTRJ 2 x RJ45 Slot C 32 5 1 6 6KQE4 3MMRJ 3 x MTRJ 1 x RJ45 Slot A Slot 32 5 1 7 6KQE4 1IMLC 1 x LC 3 x RJ45 Slot C secese 33 5 1 8 6KQE4 2MLC 2 x LC 2 x RJ45 Slot C seeen 34 5 1 9 6KQE4 3MLC 3 x LC 1 x RJ45 Slot A Slot C seee 34 5 1 10 6KQE4 xSLC LC Singlemode 20km RJ45 Module 34 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 5 1 11 6KQF xSLCL LC Singlemode 40km RJ45 Module 34 5 1 12 6KQE 2GCU 1GCU Gigabit RJ45 Copper ports Slot D 35 5 1 13 6KQE 2GSFP 1GSFP Gigabit SFP Fiber ports Slot D 35 5 2 6KQEP 48VDC Base Unit w PoE Power pass through 36 6 0 TROUBLESHOOTING cscsccstcecsccssccccssscsessssencssesscssescsseess 37 6 1 Before Calling for Assistance cceceeecsseecesecreeeeceereeceseeeseeeaeeees 37 6 2 When Calling for Assistance cee ceeeecseeeeceseeeeeseeseeeensetaeeseeneeeee 37 6 3 Return Mat
31. eo GarrettCom Industrial Networking at Its Best Magnum 6KQE Managed Edge Switch Hardware Installation and User Guide 5 00 USD Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 Magnum 6KQE Managed Edge Switch Hardware Installation and User Guide Part 84 00182Z Rev A Trademarks GarrettCom is a registered trademark and Magnum Dymec DynaStar Personal Switch Link Loss Learn S Ring Convenient Switch and Converter Switch are trademarks of GarrettCom Inc Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories Important The Magnum 6KQE Managed Edge Switch contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void If problems are experienced with Magnum 6KQE Switch products consult Section 6 Trouble Shooting Copyright 2009 GarrettCom Inc All rights reserved No part of this publication may be reproduced without prior written permission from GarrettCom Inc Printed in the United States of America GarrettCom Inc reserves the right to change specifications performance characteristics and or model offerings without notice Contacting GarrettCom Inc Please use the mailing address phone and fax numbers and email address listed below GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 7437 Phone 510 438
32. epaired units to the sender with shipping charges prepaid see Warranty Information Appendix A for complete details However if the problem or condition causing the return cannot be duplicated by GarrettCom the unit will be returned as No Problem Found GarrettCom reserves the right to charge for the testing of non defective units under warranty Testing and repair of product that is not under warranty will result in a customer user charge 38 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 6 4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom please follow these instructions 1 Package the unit carefully It is recommended that you use the original container if available Units should be wrapped in a bubble wrap plastic sheet or bag for shipping protection You may retain all connectors and this Installation Guide CAUTION Do not pack the unit in Styrofoam popcorn type packing material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shipping container 3 GarrettCom is not responsible for your return shipping charges Ship the package to GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 Attn Customer Service APPENDIX A WARRANTY INFORMATION GarrettCom Inc warrants its products to be free from defects in materials and workmanship for a pe
33. erial Authorization RMA Procedure c ccceseeeeees 38 6 4 Shipping and Packaging Information eee eseeeecneeeecneeeeeeees 39 APPENDIX A WARRANTY INFORMATION sccscsssssssscssscesssesesees 39 APPENDIX B DC Power Input essesosseserecoerosoesesesoecosososseseeccsesosoesesesoesssoe 40 APPENDIX C Internal DC Dual Source Power Input Option 43 Revisions Rev A 02 09 Initial Release Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 1 0 SPECIFICATIONS 1 1 Technical Specifications Performance Filtering Forwarding Rate Ethernet 10Mb 14 880 pps Fast Ethernet 100Mb 148 800 pps Gigabit Ethernet 1000Mb 1 488 000 pps Switching Processing Type Store and Forward with IEEE 802 3x full duplex flow control non blocking Data Rate 10Mbps 100Mbps and 1000Mbps Address Table Capacity 4K node self learning with address aging Packet buffer size 240KB for 10 100 and 120KB for 1000Mb Latency 5 us packet time 100 to 100Mbps 15 us packet time 10 to 10 Mbps and 10 to 100Mbps Throughput with 8 10 100 and 2Glink max 4 17M pps Transmit Back plane 2 66Gb s per slot Network Standards and Compliance hardware Ethernet V1 0 V2 0 IEEE 802 3 1OBASE T IEEE 802 3u 100Base TX 1OOBASE FX IEEE 802 3z 1OOOBASE X Ethernet Auto negotiation IEEE 802 3ab 1OOOBASE X Ethernet IEEE 802 1p Priority protocol IEEE 802 1d Spanning tree protocol IEEE 802 1w Rapid Spannin
34. esecaecaeeseeseeeeeaeeees 11 2 5 APplCatOns x 6 s ce a seecsoaseesasietseavetabeed ch otedeateandeiacvansiestenshees sp aiactauset 12 3 0 INSTALLATION sccccscsccscscceccsscecssccscscecsecsesssssecssssnesscssessesssesesees 16 3 1 Locating Magnum 6KQE Switches ee eeeceecseeeeceeeeeeeeeeeeeeeeeees 16 3 2 Connecting Ethernet Media oo eee eee cece ceseceseceseceeecaeeseeeeeeeeeeees 17 3 2 1 Connecting Twisted Pair CAT3 CATS UTP or STP 17 3 2 2 Connecting Twisted Pair CATSe or better UTP or STP 18 3 2 3 Connecting Single Mode Fiber Optic eee eeeeeeeeeee 18 3 2 4 Gigabit SFP Small Form factor Pluggable Transceivers 19 3 2 5 Connecting Fiber Optic Cable to SFP Transceivers 5 19 3 3 Mounting Dimensions for 6KQE with metal brackets eee 20 3 3 1 DIN Rail Mounting the Magnum 6KQE seeen 21 3 4 Powering the Magnum 6KQE Managed Edge Switch 22 35 Alarm Contacts for monitoring internal power and Software Traps 23 3 6 Connecting the Console Terminal to Magnum 6KQE eee 24 3 6 1 RS 232 DB 9 Console port Serial port pin assignments 24 4 0 OPERATION 0 sccsccsssscsssccsecscescssescsesencssesscesesssssesssssnesscsnessesonseoss 25 4 1 Switching Functionality eee cee cecseecneeeeeeeeeeeeeeeeeeeeenseeeaees 25 4 2 Auto Cross MDIX and Auto negotiation for RJ 45 ports 26 4 3 Flow control IEEE 802 3x standard cccccssessecec
35. etail and panel configurations 34 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 5 1 12 6KQE 2GCU 1GCU Gigabit RJ45 Copper ports Slot D iy SZ RCRCRURURCRURURUE YUYU uur IU ETT Se m e e m E O IL eraz XX The 6KQE 2GCU 2 port Copper Gigabit module provides two fixed 10 100 1000Mb RJ 45 ports The Magnum 6KQE offers a Gigabit option with multiple choices of Copper 10 100 1000Mbps or Gigabit SFP Fiber transceivers for the modular slot Up to two Gigabit ports maximum can be configured in Slot D only There are six LEDs provided for each Gigabit port Each Copper Gigabit port has LEDs that indicate FH Full or Half Duplex LK Link ACT Activity and 10 100 1000Mbps speed set to AUTO by default AVEURCRSRCRVECRORORCRORURORURCRORG PS U UUUUUUUUUUU Ton Pamm a Ea L L c NN Jossa aaa T E Saaa gt Le The 6KQE 1GCU 1 port Copper Gigabit module provides one fixed 10 100 1000Mb RJ 45 port 5 1 13 6KQE 2GSFP 1GSFP Gigabit SFP Fiber ports Slot D
36. f store and forward operation is that more bandwidth is available for good packets when the traffic load is greatest When the Magnum 6KQE Switch detects that its free buffer queue space is low the Switch sends industry standard full duplex only PAUSE packets out to the devices sending it packets to cause flow control This tells the sending devices to temporarily stop sending traffic which allows the traffic to catch up without dropping packets Then normal packet buffering and processing resumes This flow control sequence occurs in a small fraction of a second and is transparent to an observer Another feature implemented in the Magnum 6KQE Switches is a collision based flow control mechanism when operating at half duplex only When the Switch detects that its free buffer queue space is low the Switch prevents more frames from entering by forcing a collision signal on all receiving half duplex ports in order to stop incoming traffic Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 2 3 Managed Network Software for Magnum 6KQE Magnum 6KQE comes with licensed MNS 6K Rel v4 1 4 software or MNS 6K SECURE Rel v14 1 4 which allow the user to configure the Magnum 6KQE as a Managed Switch and implements security features and other software enabled features NOTE Magnum 6KQE managed switch will work with MNS 6K Rel v4 1 4 firmware or higher version only or MNS 6K SECURE v14 1 4 firmware or higher version only Using
37. g the unit refer back to the Installation Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connectors to ensure that they have been properly connected and the cables wires have not been crimped or in some way impaired during installation About 90 of network downtime can be attributed to wiring and connector problems 3 Make sure that DC power is properly attached to each Magnum 6KQE Switch unit Use the PWR LEDs to verify each unit is receiving power 4 If the problem is isolated to a network device other than the Magnum 6KQE Switch product it is recommended that the problem device be replaced with a known good device Verify whether or not the problem is corrected If not go to Step 5 below If the problem is corrected the Magnum 6KQE Switch and its associated cables are functioning properly 5 If the problem continues after completing Step 4 above contact your supplier of the Magnum 6KQE Switch unit or if unknown contact GarrettCom Inc by fax phone or email support garrettcom com for assistance 6 2 When Calling for Assistance Please be prepared to provide the following information 1 A complete description of the problem including the following points a The nature and duration of the problem b Situations when the problem occurs c The components involved in the problem d Any particular application th
38. g tree protocol IEEE 802 1q VLAN Tagging IEEE 802 3x Flow Control IEEE 802 3ad Link Aggregation Trunking IEEE 802 1x Port based Network access control IEEE 802 3af Power over Ethernet Maximum 10 Mbps Ethernet Segment Lengths Unshielded twisted pair 100 m 328 ft Shielded twisted pair 150 m 492 ft 10BASE FL multi mode fiber optic 2km 6 562 ft 10BASE FL single mode fiber optic 10 km 32 810 ft Maximum Standard Fast Ethernet Segment Lengths 10BASE T CAT 3 4 5 UTP 100 m 328 ft 100BASE TX CAT 5 UTP 100 m 328 ft Shielded twisted pair 150 m 492 ft 100BASE FX half duplex multi mode 412 m 1350 ft 100BASE FX full duplex multi mode 2 0 km 6 562 ft 100BASE FX half duplex single mode 412 m 1350 ft 100BASE FX full duplex single mode 20 0 km 66K ft 100BASE FX full duplex Long Reach 40 0 km 122K ft Maximum Standard Gigabit Ethernet Segment Lengths 1000BASE T CAT5e or higher is recommended 100m 328 ft 1000BASE SX full duplex multi mode 62 5um cable 220m www GarrettCom com 1 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 1000BASE SX full duplex multi mode 501m cable 550m 1000BASE LX full duplex multi mode 50 62 5um cable 550m 1000BASE LX full duplex single mode 9um cable 5km 1000BASE ZX full duplex single mode 9um cable gt 70km Fiber Multi mode connector types supported Fiber Port MTRJ type plug in SFF Fiber multi mode
39. ged switches E RSTP 2004 for rings and meshes fastest fault recovery interoperability RSTP 2004 provides reliable fast recovery from a fault in a redundant LAN which may include Magnum switches and routers as well as other vendors industry standard RSTP products Redundant topologies may include rings dual rings and complex meshes 2 5 Applications Magnum 6KQE Edge Switches offer high performance modularity and availability They provide the flexibility of 100Mbps fiber and copper ports as well as single or dual Gigabit 1000Mb ports with industry standard LAN management software Magnum 6KQE Switches are easily used in a variety of applications including client server computing secure VLAN performance upgrades to departmental networks and stream traffic for VOIP and audio video applications They can also be used in a much diversified combination of mixed media in Industrial floor applications The performance characteristics of the 6KQE Switches enable them to inter connect a series of subnets one subnet per 6KQE Switch port in a LAN traffic center The subnet connections may be via fiber or twisted pair cabling 100Mbps or 10 Mbps speed and full or half duplex The mixed media modular capability is ideal for industrial applications where existing Ethernet LAN network cabling must be accommodated The fiber built in media capability is ideal for integrating future proof fiber cabling into the LAN structure _www GarettCom con
40. h environmental conditions Advanced thermal design techniques with ribbed surface Aluminum cases for maximum heat dissipation and a sealed case design enables the unit to operate in harsh Industrial grade environments efficiently Heavy duty Ethernet Switch jobs are readily accommodated with an extended temperature rating of 40 C to 60 C by the UL Component Parts method or 40 C to 85 C by the IEC 60068 Type Test method With options such as several popular DC power input types AC power and DIN Rail mounting the hardened Magnum 6KQE is a multi purpose Industrial Ethernet Switch Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 The 6KQE managed switches also provides a PoE option via power inside PoE base unit 6KQEP 48VDC on Slot A and allows the users to utilize up to 4 ports of PoE to support 802 3af Powered devices See details for PoE base unit in sec 5 2 The Power Sourcing Equipment PSE is fully compatible with Powered Devices PD e g wireless access points IP phones that comply with the IEEE 802 3af PoE standard The PoE switch ports have an auto sensing algorithm so that they provide power only to 802 3af PoE end devices PoE is managed by a multi stage handshake to protect equipment from damage and to manage power budgets The PoE ports will discontinue supplying power when the PoE powered devices are disconnected This feature supports the 802 3af PoE PSE standard for over current protection under c
41. ill the redundant requirement with a secure and fast reconfiguration time for cable breakup when set up in a ring topology The Gigabit port option boosts the bandwidth for high speed to support the peak traffic and minimize congestion Example 3 In another application in an industrial environment a 12 port Nebs compliant 24VDC managed switch is required to meet the fiber and copper connections to cover the wider area of video CCTV The switch must be SNMP enabled and managed to easily monitor the whole setup The Magnum managed edge switch easily qualifies for this requirement with the various features and modularity it has Loaded with MNS 6K management software the edge switch provides a very effective and economical solution for the video vignette environment The security features e g port security VLANs SNMPv3 secure telnet etc also boost the Magnum managed switches to provide a very effective and reliable solution The modularity feature to support both copper and fiber at either 10 100 1000Mb speeds easily meets the various speeds of legacy and future broadband requirements In a fast growing secure video environment the 6KQE is a reliable and secure solution The modular design of the Magnum 6KQE provides a wide range of copper fiber options to meet requirements The Gigabit uplink for storage or broadband uplink allows the telecom user a very effective solution to store their sensitive data securely Magnum 6K16 2 side
42. increase operational uptime and to simplify maintenance The functionality of the Magnum 6KQE Switch 48VDC 12VDC 24VDC 125VDC and 250VDC Dual Source Option units are identical to the AC powered models Refer to the main sections of this Installation and User Guide for a detailed description of the Magnum 6KQE Switches www GarrettCom com 43 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 C3 0 DUAL SOURCE OPTION THEORY OF OPERATION The Dual Source DC power option is designed using diodes inside of the chassis on each DC power input line A diode is placed in each of the four input lines behind the four external power A SWITCH SUPPLY connection terminals so that power from an external source can only flow into the unit This B allows the unit to operate B whenever De power is correctly CHASSIS applied to either or both of the two GND GND inputs C4 0 FEATURES AND BENEFITS OF THE DUAL SOURCE DESIGN a The Switch unit can receive power from either input A or B The hub will normally draw its power from the DC source with the highest voltage at a given time b The Switch unit will not allow power to flow from a higher voltage input to a lower voltage input i e the two DC power sources are not mixed together by the hub c When one correct DC input is present the Switch will receive power if the other DC input is absent or even if it is connected with reverse polarity or
43. is to connect one of them using a fiber media converter to another Switch in the network backbone or to some other remote 100Mb device In this case it is desirable to operate the fiber link at 100Mb speed and at either half or full duplex mode depending on the capabilities of the remote device Standard commercially available Fast Ethernet media converters mostly do not support auto negotiation properly and require that the switched port to which they are connected be at the 100Mb fixed speed Attachments to a 10 100 auto negotiation port typically will not work properly The 6KQE Switch s RJ 45 ports handle this situation by configuring the ports as per desired through MNS software port settings and can check the port status of each port after the change When Magnum 6KQE RJ 45 copper ports are set for auto negotiation and are connected to another auto negotiating device there are 4 different speed and F H modes possible depending on what the other device supports These are 1 100Mb full duplex 2 100Mb half duplex 3 10 Mb full duplex and 4 10 Mb half duplex The auto negotiation logic will attempt to operate in descending order and will normally arrive at the highest order mode that both devices can support at that time Since auto negotiation is potentially an externally controlled process the original highest order mode result can change at any time depending on network changes that may occur If the device at the other end
44. l duplex and 412m at half duplex The compact size of the LC Connector reduces the size of wiring panels in wiring closets while providing the advantage of future proof fiber optic technology The cable end is a plug in connector with both fiber strands terminated in one housing that cannot be improperly inserted Each port has an Activity ACT LED indicating packets being received and a Link LK LED indicating proper connectivity with the remote device when lit The 6KQE4 1MLC copper ports support Ethernet twisted pair segments of any standard length It is equipped with a three port RJ 45 connector and offers 10 100 full half duplex auto negotiating capability on each port The RJ 45 connector is shielded to minimize emissions and will allow both unshielded twisted pair UTP and shielded twisted pair STP cable connections When installed in a Magnum 6KQE Series Managed Switch the copper ports support the standard distance of 100m on each port 33 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 5 1 8 6KQE4 2MLC 2x LC 2 x RJ45 Slot C 0 U UUUUUUUUUUUUUI OUS WFAA rSnon nN AAA 1p C TT coooa AR N ee ae gooo paa The 6KQE4 2MLC 4 port Fiber Copper modu
45. le provides two 100Mb Multimode LC Fiber ports and two 10 100Mb switched RJ 45 ports see Section 5 1 7 for more information 5 1 9 6KQE4 3MLC 3 x LC 1 x RJ45 Slot A Slot C O SEURURUAUAUEURURUEURUEURORUEY PA UUU UUU UUU UUU m Tur MN gt C AIO ic IN Go ji 1 OIO ETTA ONO O elossa E COR Oo The 6KQE4 3MLC 4 port Fiber Copper module provides three 1OOMb Multimode LC Fiber ports and one 10 100Mb switched RJ 45 ports This module option occupies parts of Slot A and Slot C see Section 5 1 7 for more information 5 1 10 6KQE4 xSLC LC Singlemode 20km RJ45 Module The 6KQE4 xSLC 4 port Fiber Copper modules provide 100Mb Singlemode LC Fiber ports supporting distances up to 20km and 10 100Mb switched RJ45 ports These modules provide the same functions as the Multimode versions see Sections 5 1 7 thru 5 1 9 for more detail and panel configurations 5 1 11 6KQF xSLCL LC Singlemode 40km RJ45 Module The 6KQF xSLCL 4 port Fiber Copper modules provide 100Mb Singlemode LC Fiber ports supporting distances up to 40km and 10 100Mb switched RJ45 ports These modules provide the same functions as the Multimode versions see Sections 5 1 7 thru 5 1 9 for more d
46. lease the 6KQE so that it can be dismounted by pulling the bottom out Once the bottom of the 6KQE is rotated out the DIN Rail bracket is not engaged and the 6KQE can be moved up and out free of the DIN Rail mounting The DIN Rail mounting bracket is optional and needs to be ordered as separate items e g Model DIN RAIL 6KQ 3 4 Powering the Magnum 6KQE Managed Edge Switch The DC internal power supply supports installation environments where the DC voltage is from 10 to 300 volts depending on the model selected The power consumption will range from about 15 up to 20 watts depending on the port quantity and types in the configuration When connecting the Ethernet cabling there is no need to power down the unit Individual cable segments can be connected or disconnected without concern for power related problems or damage to the unit Power input options are available to suit the 6KQE Switches to special high availability communications and or heavy industrial grade applications including 12VDC 48VDC 24VDC 125VDC and 250VDC with single DC input 12VDC 48VDC 24VDC 125VDC and 250VDC with dual source DC input AC input with internal power supply see Section 1 2 for Ordering Information 22 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 3 5 Alarm Contacts for monitoring internal power and Software Traps The Alarm Contacts feature standard on Magnum 6KQE s provides two Form C Normally Closed NC
47. m 6KQE Switches are fixed RJ 45 copper ports with dual speed 10 100Mbps auto negotiating capability Additionally the switch can accept up to two Port Modules to provide the user with up to 6 additional ports 10 total providing a wide selection of Ethernet copper and fiber media connections with 10 100 and 1000Mbps capability and up to 70km Note The 6KQE Port modules are not identical to the port modules used in other 6K products such as the 6K25e and 6K16V For information about other 6K products please see the applicable manual For a list of 6KQE Port Modules refer to Section 1 2 Each 6KQE Port Module PM is individually described in the following sections 28 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 5 1 1 6KQE Module LED designations 1 2 RJ45 Standard 1 ON 100Mb OFF 10Mb 2 ON Link il AN 3 ON Full Duplex OFF Half Duplex m mm 4 BLINKING Activity 3 4 1 2 RJ45 PoE 1 ON 100Mb OFF 10Mb 2 ON Link BLINKING Link Activity AANA 3 ON Full Duplex OFF Half Duplex 4 ON PoE device detected 2 BLINKING Activity 4 MTRJ Fiber d 1 ON Link 2 24 LC Fiber 1 ON Link 2 BLINKING Activity Te i Gigabit Copper Fiber 1 ON
48. mation enables a managed station a PC or Console terminal to connect directly to the switch using a straight through cable Note To use the Console port to configure the managed switch a serial Null modem female to female cable is required to communicate properly The Null Modem DB 9 cable is optional and can be ordered from the factory along with the unit as CONSOLE CBL for serial port CONSOLE USB for USB port www GarrettCom com ss 24 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 NOTE for Power Substations Jn support of the IEEE 1613 Class 2 standard GCI advises that for substation applications the serial DB 9 console ports are intended for temporary connectivity to other equipment such as PCs Since the console port connection is temporary it is excluded from IEEE 1613 packet loss testing per the 1613 standard defined test procedure 4 0 OPERATION This chapter describes the functions and operation of the Magnum 6KQE Switch 4 1 Switching Functionality A Magnum 6KQE provides switched connectivity at Ethernet wire speed among all of its ports The Magnum 6KQE supports 10 100Mbs for copper media and 100Mb separate traffic domains for fiber ports to maximize bandwidth utilization and network performance All ports can communicate to all other ports in a Magnum 6KQE but local traffic on a port will not consume any of the bandwidth on any other port The Magnum 6KQE units are plug a
49. must use the color coded strand on the associated ports at each end of the fiber optic segment ww GarrettCom com 19 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 3 Find the Transmit TX and Receive RX markings on the SFP transceiver to verify the top side of it Some of the transceiver marks arrow sign for up 4 Position the SFP transceiver correctly before insertion and then insert the SFP transceiver carefully until the transceiver connector snap into the place in the socket connector 5 Connect the Transmit TX port on the Magnum PM to the Receive RX port of the remote device Connect the Receive RX port on the PM to the Transmit TX port of the remote device The LINK LED on the front of the PM will illuminate and turn Green when a proper connection has been established at both ends and when power is ON in the unit If LINK is not lit or OFF after cable connection the normal cause is improper cable polarity Swap the fiber cables at the PM connector and also check the connectivity on the target device to remedy this situation Reconfigure or reboot both of the devices if required If connected properly you can check via MNS 6K software for verifying the validity of SFP Gigabit ports 3 3 Mounting Dimensions for 6KQE with metal brackets Each Mangum 6KQE is supplied with metal mounting brackets and screws to mount the unit securely on a panel or wall It is recommended to mount the 6KQE ver
50. nd play devices There is no software configuring necessary to be done for basic operation at installation or for maintenance The only hardware configuration settings are user options for an UP LINK Switch resides inside the unit on the 6KQE4 RJ 45 There is an optional Half Full duplex mode and 10Mbps or 100Mbps selection for the switched ports which must be configured through MNS software per unit as per the requirement The internal functions of both are described below Filtering and Forwarding Each time a packet arrives on one of the switched ports the decision is taken to either filter or to forward the packet Packets whose source and destination addresses are on the same port segment will be filtered constraining them to that one port and relieving the rest of the network from having to process them A packet whose destination address is on another port segment will be forwarded to the appropriate port and will not be sent to the other ports where it is not needed Traffic needed for maintaining the un interrupted operation of the network such as occasional multi cast packets is forwarded to all ports The Magnum 6KQE Switches operate in the store and forward switching mode which eliminates bad packets and enables peak performance to be achieved when there is heavy traffic on the network Address Learning All Magnum 6KQE units have address table capacities of 4K node addresses suitable for use in larger networks They are self l
51. owing modules can be configured in Slot C only Slot C is 10 100 RJ 45 or 100Mb Fiber only Magnum 6KQE Slot C Port Modules 6KQE4 RJ45 adds four 10 100 copper ports 6KQE4 IMMRJ adds three 10 100 copper and one MM 100Mb MTRYJ fiber ports 6KQE4 2MMRJ adds two 10 100 copper and two MM 100Mb MTRJ fiber ports 6KQE4 3MMRJ adds one 10 100 copper and three MM 100Mb MTRJ fiber ports 6KQE4 1MLC adds three 10 100 copper and one MM 100Mb LC fiber ports 6KQE4 2MLC adds two 10 100 copper and two MM 100Mb LC fiber ports 6KQE4 3MLC adds one 10 100 copper and three MM 100Mb LC fiber ports 6KQE4 1SLC adds three 10 100 copper and one SM 20Km 100Mb LC fiber ports 6KQE4 2SLC adds two 10 100 copper and two SM 20Km 100Mb LC fiber ports 6KQE4 3SLC adds one 10 100 copper and three SM 20Km 100Mb LC fiber ports 6KQF 1ISLCL adds three 10 100 copper and one SM 40Km 100Mb LC fiber ports 6KQF 2SLCL adds two 10 100 copper and two SM 40Km 100Mb LC fiber ports 6KQF 3SLCL adds one 10 100 copper and three SM 40Km 100Mb LC fiber ports MM Multi mode fiber SM Single mode fiber ww GarettCom com 0 7 7777S 4 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 Following modules can be configured in Slot D only Slot D is Gigabit Fiber onl Magnum 6KQE Slot D Port Modules 6KQE 2GCU adds two auto negotiating 10 100 1000Mb copper ports 6KQE 1GCU_ adds one auto negotiating 10 100 1000Mb copper port 6KQE 2GSFP adds two SFP pluggable open transceiver po
52. p www garrettcom com techsupport insertion_guides 6kqecg pdf for configurations and options Email info GarrettCom com for additional information Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 1 2 Ordering Information MODEL DESCRIPTION Magnum 6KQE 24VDC Magnum 6KQE Managed Edge Switch base unit with four 10 100 copper ports Up to 3 100Mb fiber ports or up to four more 10 100 copper ports or combinations may also be configured and up to 2 Gb ports are optional Heavy duty metal case IP53 for environmental protection no fans For licensed managed networks software MNS 6K RS Ring and S Ring including GUIs for ease of use and industry leading security features see separate data sheets Magnum 6KQE 12VDC Same as 6KQE 24VDC except the power input is 12VDC Magnum 6KQE 48VDC Same as 6KQE 24VDC except the power input is 48VDC Magnum 6KQEP 48VDC PoE same as 6KQE 48VDC except the four 10 100 ports are PoE enabled data pairs Magnum 6KQE 125VDC Same as 6KQE 24VDC except the power input is 125VDC Magnum 6KQE 250VDC Same as 6KQE 24VDC except the power input is 250VDC Magnum 6KQE AC Same as 6KQE 24VDC except the power input is AC 100 to 240VAC 47 to 63 Hz Please use this URL for the complete Configuration Guide for the Magnum 6KQE http www garrettcom com techsupport insertion_guides 6kqecg pdf Configuration Options Each Magnum 6KQE base unit may be configured with a choice of 2 modular slots Foll
53. priority tagged packets according to the 802 1p standard In addition to hardware support for QOS the MNS software R2 supports two priority queues that can be shared across the eight levels of defined packet priorities for application specific priority control by the user through software configuration settings Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 2 2 2 Frame Buffering and Flow Control Magnum 6KQE s are store and forward switches Each frame or packet is loaded into the Switch s memory and inspected before forwarding can occur This technique ensures that all forwarded frames are of a valid length and have the correct CRC i e are good packets This eliminates the propagation of bad packets enabling all of the available bandwidth to be used for valid information While other switching technologies such as cut through or express impose minimal frame latency they will also permit bad frames to propagate out to the Ethernet segments connected The cut through technique permits collision fragment frames which are a result of late collisions to be forwarded which add to the network traffic Since there is no way to filter frames with a bad CRC the entire frame must be present in order for CRC to be calculated the result of indiscriminate cut through forwarding is greater traffic congestion especially at peak activity Since collisions and bad packets are more likely when traffic is heavy the result o
54. rcuit to the product Minimum 18AWG cable for connection to a Centralized DC power source 1 Minimum 14AWG cable for connection to an earth wiring 2 Use only with Listed 10A circuit breaker provided in building installation 3 Complies with FDA radiation performance standards 21 CFR subchapter J or equivalent 4 Fastening torque of the lugs on the terminal block 9 inch pound max 5 To secure a centralized DC Power Source cable use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block B5 0 OPERATION Operation of Magnum 6KQE Switches with the optional 48VDC 12VDC 24VDC 125VDC or 250VDC dual source power input is identical to that of the standard single source DC powered models B6 0 TROUBLESHOOTING Please refer to Section 6 0 for troubleshooting 42 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 APPENDIX C Internal DC Dual Source Power Input Option C1 0 SPECIFICATIONS FOR MAGNUM 6KQE EDGE SWITCH Power Supply Internal 48VDC Dual Source DC Power Connector First Source A A 2nd Source B B GND ground wire connection to the hub chassis screw Input Two separate sources each at 36 60 VDC Power Supply Internal 12VDC Dual Source model Dual Src 12V DC Power Connector First Source A A 2nd Source B B GND ground wire connection to the hu
55. riod of three 3 years from the date of shipment by GarrettCom During this warranty period GarrettCom will repair or at its option replace components in the products that prove to be defective at no charge other than shipping and handling provided that the product is returned pre paid to GarrettCom This warranty will not be effective if in the opinion of GarrettCom the product has been damaged by misuse misapplication or as a result of service or modification other than by GarrettCom GarrettCom reserves the right to make a charge for handling and inspecting any product returned for warranty repair which turns out not to be faulty 39 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 APPENDIX B DC Power Input B1 0 Specifications for Magnum 6KQE Switches DC Power at 12 24 48 125 and 250VDC Power input Each Magnum Model 6KQE Managed Switch requires DC power input at 12 24 48 125 and 250VDC nominal The wide range of DC power input types qualifies this product for use in 12 24 48 125 and 250VDC applications in different industries DC Power Terminals are internally floating so that user may ground either GND ground wire connection to the 6KQE chassis screw Fig B1 0 Location of chassis ground Power Consumption 20 watts typical for a fully loaded fiber model with 2Gb 15 watts typical for 8 ports copper and 100Mb fiber 12VDC Power Input nominal range 8 to 18VDC 2
56. rts for user selectable SFP Gb transceivers in each 6KQE 1GSFP adds one SFP pluggable open transceiver port for user selectable SFP Gb transceiver Gigabit 1000Mb SFP Small Form Pluggable Transceiver option 6KQE SFP SX Gb SFP transceiver 1OOOMb SX 850nm wavelength 550m SFP ESX Gb SFP transceiver 1000Mb 1310nm wavelength 2Km SFP LX10 Gb SFP transceiver 1OOOMb LX 1310nm wavelength 10Km SFP LX25 Gb SFP transceiver 1OOOMb LX 1310nm wavelength 25Km SFP ZX40 Gb SFP transceiver 1OOOMb ZX 1550nm wavelength 40Km SFP ZX70 Gb SFP transceiver 1OOOMb ZX 1550nm wavelength 70Km g 2 3 O n a oe a T a Aian MMY eT WY ea TT Eeeooe E Power O oo0ooo oO Eaesoe S Console Port E aei e MNS 6K License _MNS 6K managed software is pre loaded from the factory S RING Key S Ring and RS Ring Redundancy Manager licensed software for redundant ring management One S Ring or RS Ring key is for licensed use one 6K managed self healing Ring CONSOLE CBL Console attachment cable Serial null modem aka X modem cable with DB 9 connectors CONSOLE USB Same as above but with USB connector DIN RAIL 6KQ Din Rail moun
57. s if a long burst of activity causes the switch to save frames until its buffer memory is full This is most likely to occur when data is moving from a 100Mb port to a 10 Mb port and the 10Mb port is unable to keep up It can also occur when multiple 100Mb ports are attempting to transmit to one 100Mb port and in other protracted heavy traffic situations Magnum 6KQE Switches implement the 802 3x flow control non blocking on Full Duplex ports which provides for a PAUSE packet to be transmitted to the sender when the packet buffer is nearly filled and there is danger of lost packets The transmitting device is commanded to stop transmitting into the 6KQE Switch port for sufficient time to let the Switch reduce the buffer space used When the available free buffer queue increases the Switch will send a RESUME packet to tell the transmitter to start sending the packets Of course the transmitting device must also support the 802 3x flow control standard in order to communicate properly during normal operation Note When in Half Duplex mode the 6KQE Switch implements a back pressure algorithm on 10 100 Mb ports for flow control That is the switch prevents frames from entering the device by forcing a collision indication on the half duplex ports that are receiving This temporary collision delay allows the available buffer space to improve as the switch catches up with the traffic flow 27 Magnum 6KQE Managed Edge Switch Install
58. seful in the telecommunication industry where it is common for facilities to operate on 48VDC power Such companies include regular and wireless telephone service providers Internet Service Providers ISPs and other communication companies In addition many high availability equipment services such as broadcasters publishers newspaper operations brokerage firms and other facilities often use a battery backup system to maintain operations in the event of a power failure It is also frequently used for computer system backup management and operations monitoring equipment The 24V and 125VDC options are particularly useful in the industrial environment where it is common for facilities to operate on 24VDC or 125VDC power The 125VDC options are mainly used in power utilities such as electrical substations electrical generating plants etc The 24VDC applications are mainly in heavy duty industrial automation such as factory floor process plants HVAC military equipment etc B4 0 6KQE 12 24 48 125 and 250VDC INSTALLATION This section describes the proper connection of the 12 24 48 125 and 250VDC leads to the DC power terminal block on the Magnum 6KQE Switch The DC terminal block on the Magnum 6KQE Managed Switch is located on the left front of the unit and is equipped with four 4 screw down lead posts The power terminals are identified as positive and negative and they are electrically floating inside the unit so th
59. shorted or grounded d Reverse polarity connections if they should accidentally occur on either input will not damage the Switch or power supply internally nor will it blow the fuse in the internal power supply because of the blocking action of the diodes This is true even if one input connection is reversed while the Switch is operating from the other source e The Switch will not receive power and will not work when both inputs are simultaneously absent or are both incorrectly connected Figure C5 0 DC Dual Source wiring connections with Dual Source option lt Dual Source Terminal block C5 0 INSTALLATION This section describes the proper connection of the 48VDC 12VDC 24VDC 125VDC and 250VDC dual source leads to the power terminal block on the Magnum 6KQE Switch shown in Figure above _ www GarrettCom com DD 44 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 The terminal block is located on the left front of the unit next to the Alarm terminal block and is equipped with four 4 screw down lead posts The primary terminals are identified as positive A negative A and the secondary power terminals as negative B positive B The chassis is earth ground GND The Dual Source terminal block for the 12 24 48 125 and 250VDC are the same Note The GND should be hooked up first The 6KQE unit has a floating ground so the user may elect to Ground either or terminal to
60. suit the customer s use Before connecting live power lines to the terminal block always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more ve potential The more ve voltage lead from a ve or ve power supply must be connected to the post labeled The connection procedure is straightforward Simply connect the DC leads to the Switch s power terminals positive and negative screws The use of Ground GND is optional it connects to the Switch chassis Ensure that each lead is securely tightened C6 0 ORDERING INFORMATION FOR DUAL SOURCE POWER To order the optional Dual Source power supply factory installed add Dual Src xxxV as a separate line item following the product model Example Magnum 6KQE 48VDC Dual Sre 48V See the Configuration Guide on the GCI web site at http www garrettcom com techsupport insertion_guides 6kqecg pdf for additional information 45
61. supply circuit to the product 3 This product shall be provided with a maximum 10A DC Listed fuse or circuit breaker in the supply circuit when connected to a 48V centralized source 4 The external power supply for DC units shall be Listed Direct Plug In power unit marked Class 2 or listed ITE Power Supply marked LPS which has suitably rated output voltage i e 24VDC or 48VDC and suitable rated output current 5 Product does not contain user replaceable fuses Any internal fuses can ONLY be replaced by GarrettCom personnel through the RMA process Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 Table of Contents Page 1 0 SPECIFICATIONS ccccccscccssessscscsssscssesssssesssssnssssssessesseesesceses 1 1 1 Technical Specifications 0 0 ee ecesesesesecseeseceeeeeeeseeecsaecaeeseeaeeeeaeeetees 1 1 2 Ordering Information eeeeeeeseeeceeceeeeeceeeecsaecesesecaeeseeneeeeeees 4 2 0 INTRODUCTION 000 000 escscccecescscscecsscnessecncscosescsescssenessesnessessessesees 6 2 1 Inspecting the Package and Product eee eeeesecse esse ceeeeseteeeeeeeeee 6 2 2 Product Description Magnum 6KQE Managed Edge Switch 7 22 1 Packet Prioritization 802 1p QOS ee eeeeesseceeteeceeceeeeeesseeeenes 8 2 2 2 Frame Buffering and Flow Control eeseeeeeeeerererererereeeseee 9 2 3 Managed Network Software for Magnum 6KQE necer 10 2 4 Features and Benefits 0 0 0 ec ecesessesecseeeececeeeceaeeee
62. t for a secure vertical mount with screws for 6KQE Dual SRC Two separate power inputs 12 24 48 125 or 250VDC KQ CABLE BKT Metal bracket for 6KQE used for cable strain relief for vertical mount CONFORM05 CRM Conformal coating heavy duty silicone at 5 mil thickness for interior PCBs PS and modules for moisture protection CONFORM14 CRM Conformal coating heavy duty silicone at 14 mil thickness for interior PCBs PS and modules for oil and gas industry _ www GarrettCom com sss ss 5 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 2 0 INTRODUCTION 2 1 Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product notify the carrier of any damage that you believe occurred during shipment or delivery Inspect the contents of this package for any signs of damage and ensure that the items listed below are included This package should contain 1 Magnum 6KQE Managed Edge Switch base unit configured with user selected port module options installed 2 Set of two metal vertical mounting brackets with screws to the case 1 6KQE Installation and User Guide this manual Remove the items from the shipping container Be sure to keep the shipping container should you need to re ship the unit at a later date In the event there are items missing or damaged contact the party from whom you purchased the product If the unit needs to be returne
63. t power_budget pdf for Power budget calculations to find fiber cable distance information 3 2 1 Connecting Twisted Pair CAT3 CAT5 UTP or STP The RJ 45 ports of the Magnum 6KQE can be connected to the following two media types 1 OOBASE TX and 1OBASE T CAT 5 cables should be used when making 100BASE TX connections When the ports are used as 10BASE T ports CAT 3 may be used In either case the maximum distance for unshielded twisted pair cabling is 100 meters 328 ft NOTE Jt is recommended that high quality CAT 5 cable be used whenever possible in order to provide flexibility in a mixed speed network since 10 100 copper switched ports are auto sensing for either 10 and 1OOMb s The following procedure describes how to connect a 1 OBASE T or 1OOBASE TX twisted pair segment to the RJ 45 port The procedure is the same for both unshielded and shielded twisted pair cables 1 Using standard twisted pair media insert either end of the cable with an RJ 45 plug into the RJ 45 connector of the port Note that even though the connector is shielded either unshielded or shielded cables and wiring may be used 2 Connect the other end of the cable to the corresponding device 3 Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established 17 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 NOTE for Power Substa
64. tically as shown on following page for proper cooling and long life reliability It is also advisable to mount the unit with space for air movement around the top and the sides typically a minimum of 1 inch Note The metal brackets supplied hold the back of the 6KQE unit out from the panel or wall behind it creating a rear space of about 1 4 inch or lcm This allows air circulation and cooling of the rear part of the case For best cooling of the 6KQE attach the metal brackets to metal rather than wood or plastic Attaching to metal helps conduct heat away from the 6KQE through the metal brackets and into the metal support structure Since the 6KQE has special internal thermal techniques patent pending to move the heat generated by the electronic components inside into the case the case may be quite warm to the touch during normal operation 20 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 9 72 8 56 0 61 7 54 i 1 09 D _ i U 87 469 60 275 The unit is mounted using the brackets as shown in the illustration above The spacing for the mounting screws into the supporting wall or panel is a rectangle 21 74 x 11 91 cm 8 5
65. tion The Magnum 6KQE switching hardware supports QoS giving packet processing priority to priority tagged packets according to the IEEE 802 1p standard For port and application specific priorities of data the QoS software may be configured Fiber Ports Built In Magnum 6KQE Managed Edge Switches are designed to naturally include fiber ports and support mixes of multi mode single mode 100Mb and 1000Mb speed full and half duplex classic Small Form Factor SFF and Small Form Pluggable SFP fiber connectors RJ 45 10 100 ports can also be configured in the mix of port types Relay Contacts for monitoring internal power and user defined software events Two Alarm Relay contacts monitor basic operations One is for hardware and will signal loss of power internally The other is software controlled and will signal user defined software events such as a security violation or an S Ring fault condition Vertical mounting for efficient convection cooling no fans extended temperature Mounting brackets for vertical mounting are included DIN Rail mounting hardware is optional Ethernet signal and power cables attach at the bottom Two sets of status LEDs are included one set viewable at the port connector and one set viewable from the front All types of power input 12 24 48 125 250VDC and AC The 6KQE can be configured with the user s choice of DC power supplies 12V and 24V for factory floor 48V for tariffed carrier field facilities an
66. tions In support of the IEEE 1613 Class 2 standard GCI advises that for substation applications the RJ 45 ports are intended for connectivity to other communication equipment such as routers or telecommunication multiplexers installed in close proximity i e less than 2 meters or 6 5ft to the 6KQE It is not recommended to use these ports in substation applications to interface to field devices across distances which could produce high greater than 2500V levels of ground potential rise GPR during line to ground fault conditions The 6KQE passes the 1613specifications for zero packet loss with fiber ports amp with RJ 45 ports used as indicated here 3 2 2 Connecting Twisted Pair CATSe or better UTP or STP The RJ 45 Gigabit ports of the Magnum 6KQE can be connected to the media types LOOOBASE T or CAT 5E or better 100 ohm UTP or shielded twisted pair STP balanced cable The CAT 5E or better 100 ohm UTP or shielded twisted pair STP balanced cable is recommended to use when making 1OOOBASE TX connections In either case the max distance for unshielded twisted pair cabling is 100 meters 328 ft The following procedure describes how to connect a 1 OOOBASE T twisted pair segment to the RJ 45 port The procedure is the same for both unshielded and shielded twisted pair cables 1 1000BASE T connections require that all four pairs or wires be connected Insert either end of the cable with an RJ 45 plug into th
67. uide On the model 6KQE4 RJ45 module there are four LEDs for each port two integrated into the connector and two below the connector The LK Link LED indicates ready for operation on that port when lit The blinking ACT Activity LED indicates receiving Activity on that port when lit The 10 100 LED indicates operation at 100Mb speed when ON and at 10 Mb speed when OFF when auto negotiation is not disabled The FDX HDX LED is ON to indicate full duplex operation and OFF to indicate the half duplex mode A twisted pair cable must be connected into an RJ 45 port and the Link LK indicator for that port must be ON indicating there is a powered up device at the other end of the cable in order for a LK LED to provide valid indications of operating conditions on that port Using the 6K MNS 6K or MNS 6K SECURE management software the user may disable auto negotiation and fix the desired operation of each RJ 45 port The user may select 1OMb or 100Mb speed and full or half duplex mode per port as per user requirements See Magnum MNS 6K Software Manual for additional info NOTE for Power Substations Jn support of the IEEE 1613 Class 2 standard GCI advises that for substation applications the RJ 45 ports are intended for connectivity to other communication equipment such as routers or telecommunication multiplexers installed in close proximity i e less than 2 meters or 6 5ft to the 6KQE It is not recommended to
68. urrent detection and fault protection High performance features include non blocking unicast traffic speed on all ports and 802 1p QoS Traffic Prioritization Magnum 6KQE switches are plug and play and are designed for use in connecting edge devices such as PLCs IEDs and PoE video cameras with upstream switches and routers where a mix of bursty data traffic and priority streaming traffic for video surveillance and cell tower applications are present Magnum 6KQE Managed Edge Switches have heavy duty aluminum cases and are readily available with standard Industrial grade 24VDC power Alternative internal DC power options are available Internal AC power and DC power input types may be 12V 24V 48V 125V 250V and dual source DC input is optional on the 6KQE Alarm Relay contacts provided on each Magnum 6KQE Switch monitor the hardware and software through traps providing a record of any losses of power signals and other user defined software events See Section 3 5 for details 2 2 1 Packet Prioritization 802 1p QOS Quality of Service means providing consistent predictable data delivery to users from datagram paths that go all across a network As a LAN device the Magnum 6KQE can do its part to prevent any QOS degradation while it is handling Ethernet traffic through its ports and buffers The Magnum 6KQE switching hardware supports the IEEE 802 1p standard and fulfills its role in support of QOS giving packet processing priority to
69. use these ports in substation applications to interface to field devices across distances which could produce high greater than 2500V levels of ground potential rise GPR during line to ground fault conditions The 6KQE passes the 1613specifications for zero packet loss with fiber ports and with RJ 45 ports used as indicated here 5 14 6KQE4 IMMRJ 1 x MTRJ 3 x RJ45 Slot C Dop ap am e p ap Aa MMG KOy C E C C EN C SZAJS poe eat A L D le E a ae Aeree SZAJA S Sasa ess 28 The 6KQE4 IMMRJ 4 port Fiber Copper module provides one 100Mb Multimode MTRJ Fiber port and three 10 100Mb switched RJ 45 ports The 6KQE4 1MMRJ fiber port is a Small Form Factor SFF MTRJ Multimode connector The MTRJ s small size and ease of connection make it a good choice for 100Mbps fiber to the desktop Ethernet connectivity When installed in a Magnum 6KQE Series Switch it supports fiber optic cable distances up to the IEEE _ www GarrettCom com sss 31 Magnum 6KQE Managed Edge Switch Installation and User Guide 02 09 standard 100Mbps distance limits i e typi
Download Pdf Manuals