Home

X - Lenord+Bauer

image

Contents

1. 15 09 ok var Wagon number 3380 zx 256 3 Last read on Reconfigured on 03 11 09 Temp gt 70 85 C EI If required specify other parameters as described above As soon as a field is changed a corresponding message appears in the Status field on the first data screen page and the Write button is enabled i RW2510 43 4 07 56 lok Status Changes not saved Serial number 1711302144 Mieage Wheelset type Wheelset number Wheel diameter Page 2 amp Page 3 gt Tap the Write button to transfer the data to the odometer The process can be aborted with the Back button Hold the handheld PC against the odometer Successful conclusion is acknowledged in the Status field The process can be re peated in the event of an error or after abortion 14 RW2510 Lenord Bauer Config mode 2 Operation i RW2510 q 14 55 ok hai Serial number Meng Wheelset type Wheelset number Wheel diameter wa Page 2 EE Page 3 gt Recommendation Check whether the data has been entered correctly in the od ometer For this purpose start a new read process by tapping the Read button After successful configuration gt quit the function with the Back button RW2510 15 3 Trouble shooting Lenord Bauer 3 Trouble shooting Data acceptance Inserted plug in card faulty Replace card with coil cover both fault in RFID reader parts fi
2. page e Page 2 3 Show next data screen page e Page 2 Page 3 Call desired data screen page directly on first page only The following table shows the parameters which can be read out Page 1 Serial number Odometer serial number according to ID plate Mileage Figure currently saved in odometer calculated from wheel revolutions displayed and specific wheel diam eter setting for wheelset Wheelset type Figure programmed by vehicle owner determined by the wheelset design Wheelset number ID number programmed by vehicle owner Wheel diameter Value configured for the wheelset cannot be changed here this is used to calculate the mileage in km from the counter reading recorded Page 2 VKM Odometer owner s ID number programmed at factory according to ERA OTIF 10 RW2510 Lenord Bauer View logfile 2 Operation Wagon number Standardised ID data UIC optional information Last read on Date of previous read process stored in odometer Mileage at Reconfigured on Date of last write process saved in odometer Mileage at Temp gt 70 85 C Yes No Status display for temperature of 70 C and or 85 C previously exceeded Page 3 Counter status Measured number of wheel revolutions U to date Memory cycles Number of mileage storage processes executed to date Resolution DZ Operating mode set in configuration mode Resolution PWRF Standard Normal operation Test Higher resolution for
3. short test tracks after a distance of approx 11 km it switches over automati cally to Standard Chip ID ID number of RFID chip used in odometer Firmware version Status of the currently installed odometer firmware gt Quit function by tapping the Back button Alternatively Press k key possibly sev eral times 2 3 View logfile This allows display of datasets saved automatically during readout in the Read mode menu The associated file RW2510 LogFile txt is located in the handheld PC s main directory Tap the View logfile button The dataset for the last readout process is displayed number in Status field The win dow may be moved towards the end or beginning of the dataset using the slide control RW2510 11 2 Operation Config mode Lenord Bauer i RW2510 Status Dataset 69 Serial number 17113021443 5 2 10 28 ok Buttons e Previous Dataset Display dataset from older Vehide Keeper ABCDE readout lower number Wagon number 338079182563 Wheelset type 004 Wheelset number 459873 Wheel diameter 920 mm e Back Close display function and switch to Start screen 03 11 09 Eina e Next Dataset Display dataset from more recent readout higher number The individual entries in the log file are described in Section 2 2 Read mode Differing and additional entries are listed below Parameter Explanation Read on at Date and time of last readout process in
4. BAUER j e Language Info The program s Start screen has two buttons in the bottom row e Language for switching from German to English and vice versa e Info for display of program information quit with ok The following functions can be called with the other Start screen buttons e Read mode For reading data out of odometer This data is displayed on several screen pages e View logfile All successful read procedures are logged and saved as individual datasets in a text file in the program directory RW2510_LogFile txt This function permits these datasets to be viewed The last dataset is always shown first The file can be scrolled with the scrollbar on the right side of the window e Config mode Use of this function is limited to the vehicle owner or other authorized person This item allows configuration of the odometer After reading out the existing data some parameters can be changed and written back e Exit Close RW2510 application Alternatives Press ex key or tap the ok icon in the headline 2 2 Read mode gt Tap the Read mode button the process is triggered as soon as the button is re leased 8 RW2510 Lenord Bauer Read mode 2 Operation The system then searches for the connected RFID reader hardware extension and displays the result in the Status field i RW2510 Status Reader found on lt COM2 gt Serial number Fa eos Wheelset type Wheelset num
5. RW2510 SENSORLINE ead and write application for en nn 0 LENORD BAUER Operating Instructions Right to technical changes and errors reserved 2009 12 Device manufacturer and publisher Lenord Bauer amp Co GmbH Dohlenstra e 32 46145 Oberhausen e Germany Phone 49 208 0 e Fax 49 208 676292 Internet www lenord de e E Mail info lenord de Doc no D 02B 2510RW RW2510 Lenord Bauer Table of contents Table of contents 1 General ve RE GE ee ee Ge ea De SE ei ee Ge EE 5 1 1 About these instructions ee EE ee ee ee ee ee ee ee ee ee 5 1 2 Target Group sae ie ea 5 1 3 Symbols markings and notes ung EE KEES ERE son keinen 5 14 Designated use Lade DR ieee ee 6 1 9 REVISIONS OE DE OE OE EL 6 2 PEDAGOG ea oe ed 7 2 BAs 7 2 2 Read mode ai RE aan 8 2 3 ole RE EE N EE ME 11 2 4 Config modes ccs eth EE ER il 12 Troubiesshoo ind is iese da EED EES REED Ee ee Re Re ER ie Re Ee ee Se N 16 PD DE NIX USS Lamaen ed ei ei de dd de ed 17 4 1 Read operating data re 17 4 2 Configure odomeler n u uce neh 18 RW2510 3 RW2510 Lenord Bauer About these instructions 1 General 1 General 1 1 About these instructions These operating instructions form part of the RW2510 user software and describe how to use it properly Read the operating instructions carefully before use and observe gt Keep the operating instructions for the entire period in which you use the software A
6. are displayed in this font Courier File names appear in this font 14 Designated use Ensure that data transmission with the handheld PC is accomplished only outside of explosion hazard areas The odometer itself may be used in such areas RW2510 is a Windows user software application for reading processing and writing data in conjunction with the GEL 2510 electronic odometer Basically the software runs on handheld PCs with WindowsMobile 5 0 Microsoft operating system or higher which have an RFID hardware extension It is factory in stalled on a Recon handheld PC and sold together with it The data is transmitted inductively and encrypted using the RFID protocol The data is stored in the odometer where it is protected against power failure It consists of e factory programmed identification data e configuration data to be specified by the owner and e regularly updated operating data such as mileage and temperature alarms The standard handheld PC provided as an option is factory equipped with an RFID data transmission module plug in card with coil cover Remove this module only in the event of a malfunction to avoid damaging the sensitive internal wiring page 16 1 5 Revisions 2009 12 18 First edition 6 RW2510 Lenord Bauer Start 2 Operation 2 Operation The program is basically operated by pressing specific buttons on the touchscreen of the handheld PC Some functions can however be performed w
7. ber C Wheel diameter l 7 ee 2 2 12 43 ok Page 3 Tap the Read button in the empty data screen displayed An acoustic signal indicates that the handheld PC is now trying to establish a con nection with the odometer Status Search for sensor 4 RW2510 t q 12 44 lok The search routine is limited to approx 30 seconds and then the process is aborted You can intentionally abort searching by tapping the Status field gt Hold the handheld PC with the coil cover a maximum distance of 3 cm from the odometer After correct alignment the acoustic signal stops and data transmission is started RW2510 9 2 Operation Read mode Lenord Bauer i RW2510 2 13 49 lok kar sensor page 4 8 Serial number EE me 9 Wheelset type Wheelset number Wheel diameter Sis Page 2 Page 3 The progress is displayed in the Status field Successful termination of the read process is confirmed by a brief acoustic signal and a corresponding message in the Status field The first of three data screen pages is displayed 4 2 10 17 ok es found and read Serial number Meng Wheelset type Wheelset number 459873 Wheel diameter ee Page 2 Page3 Buttons e Read Start new read process e Back Quit read function and switch to Start screen on first data screen page go back to screen page shown before from second
8. ith certain keys on the handheld PC All information on specific hardware keys refer to the Recon handheld PC on which RW2510 has been preinstalled Application windows shown in this man ual may differ in minor detail from those on the device used Handheld PC keys standard factory settings 1 On Off button U 4 If the display is not illuminated when you switch 2 09 4 N R s on hold the button down a little longer 2 Windows Start menu RW2510 no function 4 Windows context menu RW2510 Info screen from Start page only ER KA F 1 oz 3 Windows Start access RW2510 7 5 Close active window or screen and quit program Back or Escape 6 Enter Return key enable selected entry or press active button 7 Cursor keys 2 1 Start gt To switch the handheld PC on Press button It is important that the date and time on the system are correct for logging the read and write procedures in the odometer Forthis reason check whether the date in the system and the time on the handheld PC are set correctly if necessary correct the settings gt ie Dienstag 08 59 3 November 2009 vg Die Anmeldung bei Pocket MSN wurde Tippen Sie hier um es erneut zu versuchen RW2510 7 2 Operation Read mode Lenord Bauer Start the application by pressing the left button on the handheld PC or by tapping the RW2510 entry in the file explorer 4 44 12 38 bk SENSORLINE gt LENORD
9. or Tap the Back button to complete the function Reader handheld PC 17 4 Appendix Use Configure odometer Lenord Bauer 4 2 Configure odometer 18 Check set date and time y Start RW2510 application Y Switch the reader on y Tap the Config mode button y Tap the Read button y Bring the reader coil module in front of the sensor Y rans gt mission ok Change parameter input or selection Tap the Write button Bring the reader coil module in front of the sensor Recommendation Check _ _ Modifications Read ed 1 p 2 Data DO ____ N TA ok 7 N P p yes Tap the Back button to complete the function Reader handheld PC RW2510
10. read and con figuration mode saved in odometer Resolution DZ Factory specified resolution in revolutions U and km Resolution PWRF 1 U test mode Reconfiguration on at at Date of last write process saved in odometer with num ber of revolutions U and mileage 2 4 Config mode Use of this function is limited to the vehicle owner or other authorized person gt Tap the Config mode button RW2510 42 08 03 ok Reader found on lt com2s Serial number EET me I Wheeset type Wheelset number Du diameter AI Display and functions are basically the same as in the menu item Read mode gt page 10 gt Tap the button in the empty data entry box displayed Read and hold the handheld PC against the odometer 12 RW2510 Lenord Bauer Config mode 2 Operation i RW2510 Status Sensor found and read ME 12 47 lok Serial number Meng Wheelset type Wheelset number Wheel diameter EH Page 2 Page 3 After reading out the data it is possible to either configure a new odometer or recon figure an odometer already in operation For this purpose some of the parameters displayed in this mode can be changed The associated data fields have a white back ground such as Wheelset version in the illustration above Changeable parameters Page 1 Wheelset version Wheelset number Wheel diameter Page 2 Wagon number Temperat
11. rmly connected by cable gt Remove coil cover Turn one locking screw on each side to the release position using the flat end of the stylus and pull cover off carefully just far enough to access the plug in card Pull card out and replace Carefully replace and lock coil cover No RFID reader Operating system error in Reset found reader Depress ON button for a few seconds follow instruc tions on screen Inserted plug in card loose in Remove coil cover see above Pull card out momentarily and reinsert Carefully replace and lock coil cover Button pressed too quickly af Return to main menu and actuate ter starting the program desired button again Error code 0x01 Distance between reader and Repeat transmission process at while reading out od odometer too great or reader correct distance and at right angle ometer incorrectly aligned to odometer or as close a possible Error code 0x02 to a right angle while writing to od ometer also while reading because of saving readout date 16 RW2510 Lenord Bauer Read operating data 4 Appendix Use 4 Appendix Use The two most important RW2510 functions are shown below in a summary chart 4 1 Read operating data RW2510 Switch the reader on Check set date and time y Start RW2510 application y Tap the Read mode button y Tap the Read button Bring the reader coil module in front of the sens
12. s proprietor using company ensure that these operating instructions are acces sible to the operating personnel at all times Pass the operating instructions on to any succeeding owner or user of the software gt Include all supplements received from the manufacturer 1 2 Target group The operating instructions are intended for persons already familiar with the function and mode of operation of the GEL 2510 odometer see Operating Manual no D 02B 2510 Familiarity with Windows based operating systems is required for use of the RW2510 user software as described below The user manual included with the handheld PC provides suitable information Please also note the information given there on the fol lowing items e Battery power e Memory e Data backup and restoration Configuration of the odometer is permissible only by the owner of the vehicle or other authorized person 1 3 Symbols markings and notes The following symbols markings and notes are used in this description to ensure quick recognition of certain information RW2510 5 1 General Designated use Lenord Bauer Symbol Description Possible impending danger failure to observe can result in serious or fatal injury Indicates important information for avoiding damage to equipment and maintaining proper operation gt Required work step page 5 Cross reference to a place in this manual Times New Roman Windows specific menu items and control elements
13. ure gt 70 C Temperature gt 85 C Page 3 Resolution DZ Resolution PWRF Value determined by the wheelset version e g from the wheelset ID plate ID number e g from the wheelset ID plate Entering the correct figure is important for internal mileage calculation choice of 800 1000 mm in steps of 1 mm ID data matching the UIC specification optional informa tion Reset triggering state display Yes No Display of triggering state display yes cannot be reset by user in such cases it is necessary for the manufacturer to inspect the odometer Converting from standard to test mode and vice versa Standard Normal operation Test Higher resolution for short test tracks after a distance of approx 11 km the odometer switches over automatically to Standard gt Tap the desired parameter field Open the on screen keyboard to enter any numbers necessary Tap the icon in the centre of the bottom row of the window To select numbers from a list tap the arrow to the right of the value RW2510 13 2 Operation Config mode Lenord Bauer Type in the desired number or select the desired value from the list in a selection field Before a new value can be entered or changed the corresponding values in the entry field must be deleted occurs automatically if the value is highlighted in full as is the case when the field is selected using the cursor keys RW2510 42 4