DOCU-M0143_30100_AG-MAC PLUS English_French.indd
Contents
1. RECORD SERIAL NUMBER NOTE The tester serial number is located on the bottom of the unit Write your model number serial number and date of purchase in the space provided below Agratronix needs this information when ordering parts and when filing warranty claims Model Serial No Date of Purchase To be filled in by purchaser 21 Replacement Parts ACCESSORIES Grain Hopper Part No PLAS H0300 Battery Door Part No PLAS D0300 USB Port Cover Part No PLAS USBP USB Cable Part No 06067 Carrying Case Part No 06080 22 Manufacturer s Contact Information o o ooo eooo o o eo o o 6 6 6 0 6 6 6 6 6 6 o o 6 6 6 6 6 6 6 6 6 6 6 6 6 o Toll Free 1 800 821 9542 330 562 2222 FAX 330 562 7403 Wwww Agra Ironix com 10375 State Route 43 Streetsboro OH 44241 USA 23
2. Tester if weight test readings are not within tolerance 1 Turn on Unit press ON OFF button 2 Use UP DOWN buttons to scroll to SETTINGS then press ENTER 3 Use UP OWN buttons to scroll to Weight test Figure 7 then press ENTER 4 Place test weight or 10 new quarters into the test cell when the screen indicates to PLACE WEIGHT Once the weight or quarters are placed in unit wait for reading to display The asterisk in the upper right hand corner indicates the tester is steady and the weight is then accurate Figure 8 NOTE Tolerance is 0 1 for the number of quarters 9 9 or 10 1 is within tolerance for 10 quarters Please use 10 new quarters for your check if there is not a test weight available Weight test gt Figure 7 Weight Test Asterisk Indicates Tester is Steady Number of quarters 0 1 Figure 8 Weight Test Reading tolerance for 10 Quarters 10 Operation SELECT A DIFFERENT LANGUAGE 1 Turn on Unit press ON OFF button 2 Use UP DOWN buttons to scroll to SETTINGS then press ENTER 3 Use UP OWN buttons to scroll to Language Figure 9 then press ENTER 4 Use UP DOWN buttons to scroll to desired language and press enter to select and save this language or Press Back Arrow to abort and not select a new language Press Back Arrow to return to the active grain display where you are ready to test NOTE For English only versions English will be the only di
3. This surface should not be vibrating it can be but the more stable the more accurate the test weight measurement c There should not be a fan blowing directly on the test cell NOTE If the unit was not stable during the measurement process a warning will appear before the measurements are displayed It is recommended the tester be on a flat non vibrating surface for the readings to be accurate Any of these conditions will result in the grain test weight taking a longer time to measure and not being as accurate as it can be if these conditions are all met The entire test cell is sitting on a precision weigh scale mechanism that s why its important to keep it stable and not to drop the unit or damage may occur FOR BEST GRAIN MOISTURE RESULTS a The closer the grain and test cell temperature are to each other the better the results b The tester compensates for temperature but the grain and test cell temperature should be within 40 F of each other for best results c Use the average feature and always average 3 consecutive tests from the same grain batch Grains such as corn that have a unigue geometry can sit in the test cell slightly differently each time and add some variance in your results so averaging 3 readings will give best results NOTE Though you can hold the unit in your hand for testing that is not recommended since its hard to keep your hand stable and level for the grain test weight measurement
4. to make changes at any time without notice Components COMPONENTS PART NO DESCRIPTION PLAS H0300 GRAIN HOPPER PLAS D0300 BATTERY DOOR PLAS USBP USB PORT COVER 06067 USB CABLE 06080 CARRYING CASE Indicates manufacturer s part numbers Operation OPERATING CONDITIONS Test cell and grain MUST be free of any condensation or surface moisture Moisture on grain or in test cell will cause high readings Very hot or cool grain can pick up moisture when it warms or cools Because grains are irregularly shaped and may not always pack the same way in the test cell minor variations in readings may occur To enhance accuracy always take three 3 successive readings and average the results See page 8 for Average Moisture Measurement Functions Empty and refill the tester with new grain from the sample for test This unit will automatically average the 3 most recent test results It is important when emptying the tester to make sure there is no grain lodged in the cell top ring See page 16 for Troubleshoot ing The tester is most accurate when grain and tester are between 60 F 16 C and 90 F 32 C The unit will however operate at temperatures between 33 F 1 C and 120 F 49 C For best results grain temperature should not be below 40 F 4 C or above 110 F 43 C If the grain temperature is 40 F more or less than the temperature of the unit preheat the tester per instructions on page 05 3 Condensat
5. GRAINS LOW LIMIT HIGH LIMIT Barley 2R 4 26 Barley 6R 4 26 Corn 6 28 Millet 3 22 Oats 5 25 Rapeseed Canola 3 20 Rye 5 26 Safflower 3 20 Sorghum Milo 1 24 Soybeans 4 26 Sunflower Oil 3 22 Triticale 6 20 Wheat Durum 4 21 Wheat Hard Red Spring 5 24 Wheat Hard Red Winter 4 23 Wheat Soft Red Winter 4 22 NOTE If grain temperature is 40 F 4 C or below or 110 F 43 C or above and the grain moisture is near either the high or the low limit of the tester listed above the tester may reduce its operating limits That is if the grain temperature is 35F and rye grain lower limit is 7 moisture then the adjusted lower limit may now be 8 5 moisture due to the cold grain temperature DISCLAIMER The above moisture limits are approximate values and may vary Specifications and design are subject to change without notice Grain scales will be periodically updated with new grains and limits New grain scales and software can be downloaded from www AgraTronix com when the unit is connected to the internet via a computer and USB cord Operation OPERATING PROCEDURE PREHEATING IMPORTANT If the temperature of the grain sample is 40 F more or less than the temperature of the unit preheat the tester for best results as follows PREHEATING PROCEDURE 1 Press and release ON OFF button B to turn on tester The display C will show the name of the last grain tested at the top Secure hoppe
6. NOTE Store your tester inside your house when not in use Always store and transport your instrument in the provided carry case Remove batteries when not in use Operation AVERAGE MOISTURE MEASUREMENT FUNCTIONS There are two average functions in your tester FUNCTION 1 is AVG num This means the number of Averages AVG That is you can program your tester to automatically average up to 3 6 or 9 consecu tive moisture measurements and display the result The majority of users will not adjust the default averaging mode of averaging every 3 consecutive moisture measurements We added averaging 6 or 9 readings for users who are using the tester in unique applications FUNCTION 2 is Clear AVG Clear average will clear the current average moisture results Let s say you just took moisture measurements in one grain bin but you are now done with that grain bin Next you go to another grain bin to test another batch of grain You can clear the previous average and start fresh with the averages for your next grain bin Now Let s discuss how to use and select each of the two AVG Average moisture measurement functions FUNCTION 1 AVG num number of consecutive moisture measurements to average see Figure 4 1 Turn on Unit press ON OFF button Use Up Down buttons to scroll to SETTINGS then press ENTER Use UP DOWN Buttons to scroll to AVG num Press ENTER until your desired number to average is displa
7. Operators Manual AG MAC PLUS Grain Moisture Tester DOCU M0143 0813 Operators Manual AG MAC PLUS Grain Moisture Tester ENGLISH DOCU M0143 0813 Introduction THANK YOU for purchasing an Agratronix grain moisture tester Please treat your instrument with care Misuse such as tossing or dropping the unit can potentially damage the weigh scale mechanism or other parts of this device READ THIS MANUAL carefully to learn how to operate this unit correctly Failure to do so could result in personal injury or equipment damage THIS MANUAL SHOULD BE CONSIDERED a permanent part of this tester and should remain with the unit when you sell it RECORD SERIAL NUMBERS in the warranty section located on page 21 accurately record all the numbers Your dealer needs these numbers when you need service or parts If this manual is kept with the equipment also file the serial numbers in a secure place away from the unit WARRANTY is provided through Agratronix for customers who operate and maintain their equipment as described in this manual The warranty is explained in the warranty section located on page 21 This warranty provides you the assurance that Agratronix will back its prod ucts where defects appear within the warranty period In some circumstances Agratronix provides field improvements often without charge to the customer even if the product is out of warranty Should the equipment be abused or modified to ch
8. ange specifications the warranty will become void and field improvements may be denied If you do not understand any part of this manual and need assistance contact Agratronix Customer Service at 1 800 821 9542 All information illustrations and specifications in this manual are based on the latest information available at the time of publication The right is reserved to make changes at any time without notice Please visit us at www AgraTronix com to view this manual along with the complete line of Agratronix products Operation Operation Components Operating Conditions Operational Messages Moisture Limit Guidelines Operating Procedure Preheating Operating Procedure Normal Operation Average Moisture Measurement Functions Select a Different Grain Weight Test Test Weight Accuracy Select a Different Language Adjust Grain Offset bias calibration Clear Grain Offset Turn Backlight On or Off Temperature and Test Weight Units Auto Off Setting LCD Contrast Personalizing and Updating the Tester Troubleshooting Service Check Battery Power Levels and Replace Batteries Clean the Tester Test Cell 17 Clean the Tester Top Ring 19 Error Codes 20 Warranty 21 Record Serial Numbers 21 Accessories 22 Manufacturer s Contact Information 23 All information illustrations and specifications in this manual are based on the latest information available at the time of publication The right is reserved
9. buttons to scroll to SETTINGS then press ENTER 2 3 Use UP DOWN buttons to scroll to Auto off Figure 14 4 Press ENTER to scroll through the choices 30 seconds 1 minute 5 min 10 min or 20 min and once the desired option is displayed Press Back arrow to save it You are now back to the active grain display where you are ready to test Auto off Figure 14 Auto Off 14 Operation LCD CONTRAST You will likely not need to adjust the LCD contrast since the default setting will meet the needs of most people Be careful if you do adjust your LCD contrast since you may get to either extreme too high or too low where you can no longer see text on your display Turn on Unit press ON OFF button Use UP DOWN buttons to scroll to SETTINGS then press ENTER Use UP DOWN buttons to scroll to Contrast Figure 15 Press ENTER Press UP DOWN buttons until desired LCD contrast is achieved Press ENTER to save new contrast or press Back Arrow if you don t want to save this new contrast level Press Back arrow to return to the active grain display where you are ready to test Figure 15 Contrast Screen PERSONALIZING AND UPDATING THE TESTER 1 The tester is equipped with a USB port and when connected to the internet via a computer will allow for diagnostics and updates to its software and grain calibrations Visit www AgraTronix com to use your USB port for personalization adding user nam
10. cure battery door A A Battery Door B Batteries 4 AA alkaline batteries Figure 18 Removing Battery Door CLEANING THE TESTER TEST CELL Use a soft clean cloth to wipe out the cell using extreme care not to damage the grain temperature sensor at the bottom of the test cell Grain Temperature Sensor Figure 19 Grain Temperature Sensor 18 Service CLEANING THE TESTER REMOVAL OF TOP RING NOTE It is important when emptying the tester to make sure there is no grain lodged in the cell top ring If test weight readings appear to be inaccurate use the following steps to remove the top ring and clean out excess grain and or debris REMOVING AND CLEANING TOP RING Use a soft clean cloth to wipe out the cell using extreme care not to damage the grain temperature sensor at the bottom of the test cell Use a pointed object to pop out one of the tabs of the top ring on the inside of the cell Remove ring Turn tester upside down and gently shake back and forth to remove any grain debris that may have entered the tester Check the inside of the ring before reattaching PLACING TOP RING BACK ON UNIT 1 Align the tabs and push down 2 Lightly grab the ring and attempt to turn it making sure the tabs are locked into place NOTE Listen for the tabs to lock into place Top Ring Tab Figure 20 Top Ring Tab 19 Service IN ERROR CODES As with most test instruments there
11. e grain scale firmware and diagnostic updates 15 Troubleshooting Symptom A Unit does not power up or loses power occasionally Solution 1 Press ON OFF button for shorter time Do NOT hold button down Solution 2 Check batteries for 0 or higher Replace as necessary Solution 3 Confirm all four batteries are properly oriented Symptom B Unit is inaccurate Solution 1 Temperature of the grain and unit may be more than 40 F different Follow preheat procedure See page 4 Solution 2 If grain is at an extreme temperature let grain settle to reach room temperature Retest grain Solution 3 Grain and or test cell may have developed surface moisture from rapid change in temperature of the grain sample Allow grain and tester to stabi lize near room temperature Inspect for visible moisture on grain and inside test cell Dry the test cell with a soft cloth or a blow dryer if necessary Retest grain Solution 4 If the tester displays BATTERY LOW the test results may be inaccu rate Replace battery Solution 5 Check for lodged grain under cell top ring and use weight test under settings menu see page 10 Grains that are smaller in nature or carry debris are more likely to get lodged For cleaning instructions see page 18 Solution 6 Unit may need to be recalibrated by factory Return tester to your Agratronix dealer for repair or replacement or call Agratronix customer service at 1 800 821 9542 Symptom C Unit sh
12. e pour hole Pull level arm towards the display and lift up on Hop per G to remove it Figure 3 Place it to the side in a safe place where it won t be dropped Level Grain When prompted push grain level arm I in a slow steady motion towards the back of the unit to push excess grain out of the test cell For some grains you may not be able to initially do this with in one motion and if so then pull the level arm half way back and push again toward the Figure 3 Pull level arm forward back of the test cell to level the grain Lift hopper up Pull level arm back towards the display Look at the level arm brush and ensure it is not touching the test cell or the grain test weight will be affected Once level arm returns toward the display take hands off the tester if it s sitting on a flat surface and it will automatically start measuring Remove hands and keep stable since test weight is the first part of the measurement Done The measurement results test weight grain temperature and average test results are now displayed NOTE Don t swipe grain too fast with grain level arm A Test Cell B ON OFF Button C Display D UP DOWN Arrows E BACK Arrow F ENTER TEST Button G Grain Hopper H Grain Hopper Slider Level Arm with Brush Operation FOR BEST GRAIN TEST WEIGHT RESULTS a Sit tester on a semi level flat surface with an angle of less than 5 b
13. ing see page 16 for Troubleshooting SECURING THE HOPPER 1 Place the back hopper tab into the center of the base Figure 2a 2 Pulllevel arm forward Figure 2b and the hopper will lock into place once the level arm is released Back Hopper Tab Figure 2a Tab Placement of Hopper Figure 2b Pull level arm forward OPERATING PROCEDURE NORMAL OPERATION 1 Place Hopper on Tester Secure empty grain hopper G to the top of your tester Press and release ON OFF button B to turn on tester The top of the display C will show the name of the last selected or tested grain If this grain has never been tested then the values that show the last test will be empty At power up the display shows the results of the last grain tested Select Grain If the desired grain is not shown at the top of the display C then use the UP DOWN arrows D to choose grain Once the desired grain is selected then press and release the ENTER F button to make it your active grain Place tester on a stable and mostly level surface Press ENTER to initiate test Fill Hopper Fill hopper to the rim with grain to be tested ensure hopper Slider H is pushed in to keep grain from dropping early When prompted Pour Pull the hopper slider H This will evenly drop grain into the test cell A Operation 5 When prompted remove Grain Hopper G Once test cell is full then push the hopper slider H back in to close off th
14. ion on the grain or test cell is best avoided by having the tester and grain at similar temperatures The environment to which a grain sample is exposed can appreciably change its moisture content Exposed to the open air grain can gain or lose 1 to 2 indicated moisture in only a few minutes If a sample is to be held for even a short time before being tested it should be placed into a tightly closed air tight container such as a re closable bag or airtight plastic container OPERATIONAL MESSAGES Symbol Definition BATTERY LOW Battery needs replacing lt 4 0 Moisture is below the lower limit for this grain 4 is lower limit for selected grain gt 28 0 Moisture is above the upper limit for this grain in this case 28 0 is the upper moisture limit for the selected grain Error code refer to error code section on page 20 in the manual Operation CAUTION Please treat your instrument with care Misuse such as tossing or dropping the unit can potentially damage the weigh scale mechanism or other parts of this device Use a soft clean cloth to wipe out the cell using extreme caution no to damage the grain temperature sensor at the bottom of the test cell It is important when emptying the tester to make sure there is no grain lodged in the cell top ring see page 16 for Troubleshooting Display Reading Moisture Limit Guidelines Specifications and design subject to change without notice MOISTURE RANGE MOISTURE RANGE
15. isture calibration in the tester TO ADJUST GRAIN OFFSET 1 Turn on Unit press ON OFF button 2 Use UP DOWN buttons to scroll to GRAIN OFFSET then press ENTER 3 Use UP DOWN buttons to make the desired adjustment 4 Press ENTER to save this offset or press back arrow to not save it You are now back to active grain display where you are ready to test Grain Offset gt Figure 10 GRAIN OFFSET NOTE The grain offset adjustment bias calibration is applied to the last grain you tested since a test must be made prior to knowing what adjustment to apply CLEAR GRAIN OFFSET 1 Turn on Unit press ON OFF button 2 Use UP DOWN buttons to scroll to GRAIN OFFSET then press ENTER 3 Use UP DOWN buttons to make adjustment 0 0 4 Press ENTER after displaying the save disc icon the unit takes you back to the active grain display and ready to test ee a a Figure 11 GRAIN OFFSET 12 Operation TURN BACKLIGHT ON OR OFF To extend battery life turn your LCD display backlight off if you don t need it When outside in the daylight you will likely not need the backlight on TO TURN THE BACKLIGHT ON OR OFF Turn on Unit press ON OFF button Use UP DOWN buttons to scroll to SETTINGS then press ENTER Use UP DOWN buttons to scroll to Backlight Press Enter to toggle the backlight on or off Press Back arrow when done You are now back to the active grain display where you are read
16. mi level surface surface e Repeat test Grain weight greater e After swiping make sure swiper is fully 16 than 330 grams returned e Perform Weight Test 17 Grain weight less than e Clean cell and top ring 50 grams e Perform Weight Test Grain weight more than Meter automatically compensated for weight 20 higher than the Scale is based on a different test weight nominal weight e Clean top ring and perform Weight Test Grain weight more than Meter automatically compensated for weight 20 lower than nominal Scale is based on a different test weight e Clean top ring and perform Weight Test 20 Cup not empty in e Ensure cup is empty measurement cycle Repeat test 20 Warranty WARRANTY This product is guaranteed to be free from defects in materials and workmanship for one 1 year from date of retail purchase This warranty does not cover the batteries or damage resulting from misuse neglect accident or improper installation or maintenance This warranty does not apply to any product which has been repaired or altered outside an authorized factory repair facility The foregoing warranty is exclusive and in lieu of all other warranties of merchantability fitness for purpose and any other type whether express or implied Agratronix neither assumes nor authorizes anyone to assume for it any other obligation or liability in connection with its product and will not be liable for consequential damages
17. ows MOISTURE BELOW LIMIT or MOISTURE ABOVE LIMIT Solution 1 Grain may be too wet or dry to test Check moisture limit guidelines on page 3 of Operating Instructions NOTE Limits shown on page 3 are only guidelines and subject to change 16 Service CHECK BATTERY POWER LEVEL AND REPLACE BATTERIES The tester is supplied with four AA alkaline batteries A Battery Door B Batteries 4 AA alkaline batteries NOTE Remember to remove batteries when unit is not in use after the season VOI rrosion A to avoid corrosio Figure 16 Battery Door and Batteries CHECK BATTERY LEVEL Turn on Unit press ON OFF button Use UP DOWN buttons to scroll to SETTINGS then press ENTER Use UP DOWN buttons to scroll to Battery Press ENTER Percent of battery life remaining is displayed Figure 17 Press Back Arrow when done Press Back Arrow one more time to return to active grain display where you can take a test Figure 17 Battery Percentage 17 Service REPLACE BATTERIES Per the above instruction first Check Battery Level If battery level is lower than 15 then it s recommended you replace batteries with four 4 new AA Alkaline Batteries B To replace batteries Remove battery door A Figure 18 Remove and properly dispose of the four AA alkaline batteries B Replace with 4 new AA alkaline batteries B pay special attention to the battery polarity Replace and se
18. r G to the top of the tester see page 5 for instructions on securing hopper 2 When the grain to be tested has been selected using the UP DOWN arrows D fill the grain hopper G and pull hopper slide H to drop the grain into the test cell Allow grain to sit in the hopper as short of a time as possible since the hopper temperature will alter the grain temperature 3 After 30 to 60 seconds empty test cell and immediately refill with fresh grain 4 Take a test with this fresh grain Now the test cell and grain should be close enough in temperature to give a good reading Note The most accurate moisture measurements are achieved when the test cell and grain temperature are similar A Test Cell B ON OFF Button C Display D UP DOWN Arrows E BACK Arrow F ENTER TEST Button G Grain Hopper H Grain Hopper Slider Level Arm with Brush gt Figure 1 AG MAC PLUS Unit Operation CAUTION Please treat your instrument with care Misuse such as tossing or dropping the unit can potentially damage the weigh scale mechanism or other parts of this device To add the ability to measure grain test weight results in a more complex grain testing instrument Use a soft clean cloth to wipe out the cell using extreme caution no to dam age the grain temperature sensor at the bottom of the test cell It is important when emptying the tester to make sure there is no grain lodged in the cell top r
19. splayed language Language gt Figure 9 Language Selection ADJUST GRAIN OFFSET Let s start with an overview of grain offset An offset is the way you adjust your tester to your local grain elevator s table top tester Some people call it a calibra tion some call it an offset and others call it a bias but all three terms mean the same thing Let s say your tester measures a sample of corn at 15 moisture but your local grain elevator tester measures it at 14 5 What you can do is pro gram a 0 5 moisture enter a 0 5 offset to your tester so it matches the grain elevator NOTE It s not uncommon to take your load of grain to two different grain elevators and get a different result from each of their grain elevator testers NOTE An offset adjustment can NOT be made to produce moisture readings that are below or above the moisture limit for the selected grain IMPORTANT Always obtain three test results from the grain elevator for the sample being compared The unit will average these three results Compare this average with the average of three tests by your moisture tester before making an offset adjustments 11 Operation Each grain can be individually adjusted by 10 0 in increments of 0 1 to more closely match the results of an elevator tester The calibration adjustment typi cally compensates for the differences in the variety hybrid of grain you are testing relative to the varieties used to develop the grain mo
20. will be things you do that are outside of the limits of the tester or things that affect the accuracy There will also be some error codes that warn you about a fault in your tester Below is a list of the current error codes Always check our web site at www AgraTronix com under the links for this tester for the updated manual to find all error codes Error Code Cause Solution Memory Failure e Call for service 1 800 821 9542 Grain Not Detected e Repeat test e Grain in test cell too e Clean cell and top ring soon e Repeat test Weight Scale Defective Perform Weight Test Weight did not settle e For better accuracy place tester on a within normal time limits non vibrating semi level surface Moisture measurement e Repeat test took too long to settle Same as 9 except tester Put tester on non vibrating semi level surface stopped trying to find e Repeat test stable weight 40 Grain temperature lower Displayed moisture will be less accurate than than 36F if the grain were at a higher temperature 13 Grain temperature higher Displayed moisture will be less accurate than than 122F if the grain temperature was below 122F Large temperature Meter automatically compensated for difference between the temperature difference for better accuracy 14 grain and meter test cell grain and meter test cell should be at similar temperatures e See Preheating Procedure 15 Not on a sufficiently level Place tester on a se
21. y to test Backlight gt MM lt Backlight On Figure 12 Backlight TEMPERATURE AND TEST WEIGHT UNITS When the temperature units are changed from Fahrenheit to Celsius the test weight units are also changed e If you select Fahrenheit then you will get test weight in Ib bu pounds per bushel e If you select Celsius then you will get test weight in kg hl Kilograms per Hectoliter TO CHANGE TEMPERATURE AND TEST WEIGHT UNITS 1 Turn on Unit press ON OFF button Use UP DOWN buttons to scroll to SETTINGS then press ENTER Use UP DOWN buttons to scroll to Units Figure 13 Press ENTER to toggle the between F Fahrenheit and C Celsius Press Back arrow when done You are now back to the active grain display where you are ready to test 13 Operation Temperature amp Test Weight Units Figure 13 Temperature and Test Weight Units AUTO OFF SETTINGS Auto Off setting allows you to select the length of time you want your tester to automatically turn off auto off after the last button press no activity The default setting of 5 minutes should suffice but if not then change it to meet your needs Example if your Auto off is set at 5 minutes then if you turn your unit on and walk away and thus don t touch a button for 5 minutes then your tester will automatically turn off to conserve battery life TO CHANGE YOUR AUTO OFF SETTING 1 Turn on Unit press ON OFF button Use UP DOWN
22. yed 3 6 or 9 Press back arrow to return to the grain to be tested lt Number to Average Figure 4 AVG num Display in Menu Example You can take 3 consecutive moisture tests from the same batch of grain If test 1 is 15 5 test 2 is 15 3 and test 3 is 15 7 then the average moisture dis played will be 15 5 moisture average of the 3 consecutive tests The current moisture is also always displayed for each test Operation Function 2 Clear AVG Clear the current averaged moisture measurement results and start a new average for your next consecutive measurements 1 Turn on Unit press ON OFF button 2 Use UP DOWN buttons to scroll to Clear AVG then press ENTER unit displays the disc save icon so you know it reset the current averages Clear Avg gt Figure 5 CLEAR AVG SELECT A DIFFERENT GRAIN 1 Turn on Unit press ON OFF button 2 Use UP DOWN buttons to scroll to desired grain then press ENTER Top of the display now shows your selected grain New Grain gt Figure 6 GRAIN SELECTION Operation WEIGHT TEST CHECKING TEST WEIGHT FOR ACCURACY Weight Test Allows user to check the calibration of the test weight function of the tester By following the steps indicated the final reading will let the user know if the test weight is off Test weight reading errors could indicate that grain or debris is stuck under the top ring or load cell is damaged See page 18 Cleaning the
Download Pdf Manuals
Related Search
Related Contents
12ft / 3.65m Combo - Global Trampolines MV700A Usuarios Finales con Linux. Manual de Configuración e Instalación. Manuale installazione, uso e manutenzione RBS 24 RAIN (EN): c5std_manual_en Manuel d`utilisation - EV Hunter Scope with H130/H59/H425 Manual Milwaukee 2753-22 Use and Care Manual Copyright © All rights reserved.