1. 2 DMX 3 DMX 3 PINTO 5 PIN CONVERSION CHART Conductor 3 Pin Female output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data signal Pin2 Pin2 Data signal Pin 3 Pin 3 Do not use Do not use Do notuse Do not use 4 OPERATING INSTRUCTIONS Control Panel Functions BUTTON MODE OOO MODE UP DOWN ENTER FUNCTION Exits from the current menu or function UP Navigates upwards through the menu list and increases the numeric value when ina function DOWN Navigates downwards through the menu list and decreases the numeric value when in a function ENTER Enables the currentiv displaved menu or sets the currentiv selected value in to the selected function Menu Map MAIN SUB FUNCTION FUNCTION SELECTION INSTRUCTION DMX ADDRESS 001 512 Set DMX start address DIMMER RED User can combine RED GREEN BLUE GREEN 000 255 and WHITE togenerate a custom sa 0 STATIC COLOR BLUE 0 100 jcolor WHITE STROBE 00 20 Select strobe frequencv AUTO SHOW AUTO 01 20 JSPEED O 255 auto programs and speed available ACH 6CH CONTROL 11CH f MODE DMX channel mode setting 16CH 21CH ID 1 66 Assign ID address for fixtures ID SWITCH OFF ON JEnableor disable ID FAST FAST means select linear dimming DIMMER MODE SMOOTHT means select dimming SMOOTH cur
2. 2 Press ENTER select by pressing UP DOWN untilis ID SWITCH displayed 3 Press ENTER turn on or off ID addressing by pressing UP DOWN buttons 4 Press MODE to exit For every DMX512 address the user can set 66 separate ID addresses ID addressing is a secondary function in DMX512 mode In DMX512 Controller Mode the user can simultaneously control the individual DMX address of all lights and can control the lights which have separate ID address in independent DMX512 DMX address 001 DMX address 001 DMX address 001 DMX Address 008 DMX Address 008 DMX Address 008 ID address 01 ID address 02 ID address 03 ID address 01 ID address 02 ID address 03 Select 11 channel on fixture s control panel Please refer to DMX512 Channels Selection The figure above shows a simple DMX lavout which has used three units at each DMX address The three units have different ID addresses In the DMX address 001 the user can control the first three lights simultaneousiv When using channel 11select the channel number is 020 029 and ID Address 02 the controller can control the second light individuallv When using channel 11 select the channel number is 000 010 and ID Address 00 all the lights are in common use at the same DMX address
3. O Show Atelier DIALighting COB Blinder WHITERGBW 4x100W mkII 1 BEFORE YOU BEGIN What is included e 1x Fixture 1x Power cable with plug e 1x User Manual Unpacking Instructions Immediately upon receiving a fixture carefully unpack the carton check the contents to ensure that all parts are present and have been received in good condition Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling Save the carton and all packing materials In the event that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing AC POWER This fixture has an auto switching switch mode power supply that can accommodate a wide range of input voltages The only thing necessary to do before powering on the unit is to make sure the line voltage you are applying is within the range of accepted voltages This fixture will accommodate between 100V and 240V AC 50 60 Hz Each light is connected end to end by the power socket POWER IN and POWER OUT on the light or use the waterproof power cord Please ensure the head and the tail tightening when connect the lights to prevent the power leakage occurred by water seepage to the plug Help preserve the environment Ensure that this product is recycled at the end of its life Your supplier can give details of local arra
4. temperatures higher than this Never connect the device to a dimmer pack 2 INTRODUCTION Specifications Voltage Rating AC100V 240V 50 60Hz Power Rating 400W LED Quantity 4X100W 4 in 1COB LED RGBW LED 600mA BeamAngle 70 Ingress Protection indoor Product Size 438x400x175mm N W 10Kg Features RGBW color mixing with or without DMX controller Operating Modes DMX512 Connection Master amp Slave DMX Channels 4 6 11 1 11 2 16 21 channels 4 channel RGBW control 6 channel RGBW strobe auto 11 CH 1I Dimmer RGBW color macro strobe auto auto speed dimmer speed ID 11 CH 2I Dimmer RGBW pixel control strobe dimmer speed ID 16 channel RGBW pixel control 21 channel RGBW pixel control color macro strobe auto auto speed dimmer speed Bright large diode COB LEDs for vibrant colors Individual pixel control for pixel mapping options Product Overview s 9 3 SETUP Installation Requirement This product can be used in a variety of situations can hang and put on the ground If hanging the fixture for over head use then please follow the below steps Please choose the suitable location to put or hang the light when installing it You must use the exclusive clamp hanger and screw wh
5. ID13 225 ID36 248 ID59 140 149 ID14 226 ID37 249 ID60 150 159 ID15 227 ID38 250 ID61 160 169 ID16 228 ID39 251 ID62 170 179 ID17 229 ID40 252 ID63 180 189 ID18 230 ID41 253 ID64 190 199 ID19 231 ID42 254 ID65 200 209 ID20 232 ID43 255 ID66 210 ID21 233 ID44 211 ID22 234 Id45 16 21 channels 16 Channel 1 LED1 21 Channel 1 LED1 Value 000 255 Description RED 0 100 2 LED1 2 LED1 000 255 GREEN 0 100 3 LED1 3 LED1 000 255 BLUE 0 100 4 LED1 4 LED1 000 255 WHITE 0 100 LED 4 LED 4 000 255 RED 0 100 LED 4 LED 4 000 255 GREEN 0 100 LED 4 LED 4 000 255 BLUE 0 100 LED 4 LED 4 000 255 WHITE 0 100 LED 4 000 009 No Function 010 255 Macro color control 18 000 255 strobe 000 009 No Function 010 019 AUTO 1 020 029 AUTO 2 030 039 200 255 AUTO 20 000 255 AUTO speed slow to fast 000 255 Dimmer speed fast to slow ID Address Instructions 1 Setting ID address 1 Access control panel function by pressing MODE until ID is displayed 2 Press ENTER increase or reduce ID values by pressing UP DOWN between 01 and 66 3 Press MODE to exit 2 Enable or disable ID PERSONALITY ID SWITCH ON OFF 1 Access control panel function by pressing MODE until PERSONALITY is displayed
6. en hanging it and make sure the weight of the light is within limits of the hanger Please make sure without any flammable objects within 0 5m when installing the light The installation should be operated by professional person any irregular installation will cause the body injury or equipment damage Block access below the work area and use suitable and stable platform when installing or servicing fixture Safety Cable Note the cable must be secured through the heat sink ventilation passageway Hanging Clamp Note sold separately Connection of DMX Signal Wire Please use the fixture controller wire specially when use the DMX512 Controller Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming from the first fixture which will have a male 3 pin connector to the input connector of the next fixture consisting of a female 3 pin connector Then proceed to connect from the output as stated above to the input of the following fixture and so on 3 This product can be connected numerous lamps in series without the need for the signal amplifier the signal will not be weakened O e e C 4 Q 4 te 4 Q At 3 PIN TO S PIN CONVERSION CHART Notel If vou use a controller with a 5 pin DMX output connector vou will need to use a 5 pin to 3 pin adapter
7. ite strobe RGB as ground color can choosable only 11CH 210 249 250 255 Convert to 11CH 2 only 11CH 000 255 AUTO speed 000 255 Dimmer speed 000 255 ID address selection 11 channels 2 Channel iy Value 000 255 Description dimmer 000 015 No Function 016 031 R 032 047 G 048 063 B 064 079 R G 080 095 G B 096 111 R B 112 127 R G B 128 143 Ww 144 159 R W 160 175 GHW 176 191 B W 192 207 R G W 208 223 G B W 224 239 R B W 240 255 R G B W 6 000 004 No Function 005 255 strobe 0 20HZ Ty No Function 8 000 249 No Function 250 255 Convert to 11CH 1 9 No Function 10 FADE 000 255 Dimmer speed fast to slow 11 ID 000 255 ID address selection ID ADDRESS SELECTION VALUE FUNCTION VALUE FUNCTION VALUE FUNCTION 000 009 All lds 212 ID23 235 ID46 010 019 ID1 213 ID24 236 ID47 020 029 ID2 214 ID25 237 ID48 030 039 ID3 215 ID26 238 ID49 040 049 ID4 216 ID27 239 ID50 050 059 IDS 217 ID28 240 IDS1 060 069 ID6 218 ID29 241 ID52 070 079 ID7 219 ID30 242 ID53 080 089 ID8 220 ID31 243 ID54 090 099 ID9 221 ID32 244 ID55 100 109 ID10 222 ID33 245 ID56 110 119 ID11 223 ID34 246 ID57 120 129 ID12 224 ID35 247 ID58 130 139
8. ngements for the disposal of products Safety Instructions WARNING Please read these instructions carefully which includes important information about the installation usage and maintenance of this product The following symbols are used to identify important safety information on the product and in this manual AAA AA DANGER DANGER WARNING WARNING WARNING Safety hazard Hazardous Fire hazard LED light Refer to user Risk of severe Voltage Risk of emission Risk injury or death lethal or severe of eye injury electric shock This light belongs to grade protection device therefore the light must connect to the earth excellently And the power connection must be operated by the professional technician Make sure that the working voltage will not higher or lower than the rated value Make sure that the cable didn t be damage or lacerated by sharp The light must be power off when it s standing idle or before clearing The cable must with plug and you must pull out the cable by handle the plug Please be careful when installing the lighting Never touch the bared cable or it will cause the deadly electric shock Please use the suitable and safe cable to connect the light Please never remodel the light randomly we will not take the guarantee for the faulty and damage which caused by dismantle repair or remodel of the nonprofessional person Maximum ambient temperature 40 C Do not operate fixture at
9. ves to control the dimming speed PERSONALITY ON Display is always on Display switches off and goes into DISPCAY 30S Sleep mode if the controls have not been pressed for 30 seconds REVOLVE 0 90 180 270 COB LED can rotating by direction of Auto INFO VERSION CPU firmware version Master Slave Control Mode 1 Setting master machine Access control panel function by pressing MODE until AUTO SHOW is displayed Press ENTER select AUTO 01 20 by pressing UP DOWN buttons Press ENTER and then press MODE to exit 2 Setting slave machine Access control panel function by pressing MODE until DMX ADDRESS is displayed DMX512 Controller Mode 1 Setting DMX512 Address DMX ADDRESS 001 512 Access control panel function by pressing MODE until DMX ADDRESS is displayed Press ENTER add or reduce channels by pressing UP DOWN between 001 and 512 Press MODE to exit 3 Setting Channels CONTROL MODE 4CH 6CH 11CH 16 CH 21CH Access control panel function by prekssing MODE until CONTROL MODE is displayed Press ENTER button select DMX channel by pressing UP DOWN Press MODE to exit DMX512 Channel Values 4 6 11 channels 4CH 6CH Value Description 000 255 Dimmer 000 255 Red 000 255 Green 000 255 Blue 000 255 White 000 009 No Function 010 255 Macro color control 000 004 No Function 005 255 strobe 000 009 No Function 010 019 AUTO 1 020 029 200 209 AUTO 20 wh