Home
Technical Specification
Contents
1. ULTRA FLANGER UF300 JUST LISTEN Thank you for showing your confidence in us by purchasing the BEHRINGER ULTRA FLANGER UF300 This high quality effects pedal delivers two flangers in one from jet plane thick chorus vibrato to short delay effects Thanks to its high performance features you can choose between classic and detuned flanger effects with extensive parameter controls for awesome sound shaping Originally the flanger effect was generated with two tape recorders running synchronously The same audio signal was recorded on both machines If you put a finger on the left spool of one of the machines the spool and the playback speed are slowed down The generated delay results in phase shifting of the signals 7 8 9 1 CONTROLS w G 5 e e e e e MIN MAX MIN MAX MIN MAX MIN MAX Eiza OUT BEHRINGER 4 8 ULTRA FLANGER Top view The MODE switch lets you choose between negative feedback Mode 1 or positive feedback Mode 2 flanger modes Negative feedback means that the delayed signal is inverted before it is fed back to the original signal In positive feedback mode the delayed signal is not inverted In this case the effect has a more detuned character perfect for vibrato effects With the MANUAL control you can adjust the flanger delay time Longer delay times produce a sharper more detuned sound very close
2. to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Important information Changes or modifications to the equipment not expressly approved by MUSIC Group can void the user s authority to use the equipment behringer com
3. Han OCO6eHHO Npr NOBPEKAEHNAX CeTeBOrO NpOBOAA NNN CETEBO BUNKM KOMEL P kyi LAAN SB CME LVY CK EEN TERICRU ANCA RMOSEEA LCC REY NTA RECURS BaA FSU lt S ATF TIA LEBEICIL UTM CABLOY AT OBBEA Liom BIC CHR ESV ASSETS ACEH TT 8D BEE HE eR ZEA TE AE ANE CLT PRESERN RADE ARR HERA BUNT WARIS A RAR EEE E Die deutsche Anleitung ist erhaltlich www behringer com Manuel francophone en t l chargement sur www behringer com Manual en espa ol disponible en www behringer com Manuali italiani disponibili www behringer com PyCCKOA3bI4HOe pykoBOoACTBO www behringer com Polska instrukcja dost pna jest pod adresem www behringer com Nederlandse handleiding beschikbaar www behringer com Suomenkielinen k ytt ohje saatavilla osoitteesta www behringer com Svensk manual finns tillg nglig p www behringer com Dansk vejledning findes p www behringer com Manual portugu s dispon vel www behringer com EAANVIKO eyxeip io UTTAPXE SIABEGIUO OTN SieUBuvoN www behringer com HAIRY 2 7 7V www behringer com AEAEE www behringer com F Technical specifications and appearance subject to change without notice The information contained herein is correct at the time of printing The names of companies institutions or publications pictured or mentioned and their respective logos are registered trademarks of their respective owners Their use neither constitutes a claim of the trademarks by BEHRINGER nor affiliation of the
4. PSU SB USA Canada 120 V 60 Hz U K Australia 240 V 50 Hz China Korea 220 V 50 Hz Europe 230 V 50 Hz Japan 100 V 50 60 Hz Power connector 2 mm DC jack negative center Battery 9 V type 6LR61 Power consumption 30 mA Dimensions H x W x D approx 54 mm 2 1 8 x 70 mm 2 3 4 x 123 mm 4 4 5 Weight approx 0 33 kg 0 73 Ibs BEHRINGER is constantly striving to maintain the highest professional standards As a result of these efforts modifications may be made from time to time to existing products without prior notice Specifications and appearance may therefore differ from those listed or shown 4 SAFETY INSTRUCTIONS Do not use near water or install near heat sources Use only authorized attachments accessories Do not service product yourself Contact our qualified servicing personnel for servicing or repairs especially when power supply cord or plug is damaged No utilizar cerca de agua o instalar cerca de fuentes de calor Utilice s lo accesorios y aditamentos autorizados No intent reparar el producto usted mismo Contacte a nuestro personal t cnico cualificado para servicio y reparaciones especialmente cuando la fuente o el cable de alimentaci n est n da ados He okcnnyaTupyiite npu6op B NN3N OT NCTOYHMKOB BOAbi Nn Tenna MpumeHAite TONbKO ABTOPU3ZOBaHHbIe AONONHNTENbHbIe ycTpovictBa Hnkorga He peMmoHTnpy Te nprn Oop CaMOCTOATENbHO PEMOHT MOKET NpPONSBOAMTb TONbKO KBANNNLUNPOBAHHbI cneynannsnpoBaHHbi nepco
5. to a chorus effect Turn up the DEPTH control to achieve a fuller and deeper effect sound The RATE control determines the speed of the flanger effect The RES onance control determines the amount of output signal fed back to the flanger input to increase the resonance frequency That way the flanger effect gets more intensive The ON BATT LED illuminates when the effect is activated It also serves as a battery level indicator Use the footswitch to activate deactivate the effect Use this 1 4 TS IN connector to plug in the instrument cable The 1 4 TS OUT connector sends the signal to your amp Use the DC IN connection at the front of the unit to plug in a 9 V power supply not included The BATTERY COMPARTMENT is located underneath the pedal cover To install or replace the 9 V battery press the hinges with a ballpen and remove the pedal cover Be careful not to scratch the unit gt ULTRA FLANGER UF300 JUST LISTEN gt The UF300 has no on off switch As soon as you insert the jack into the IN connector the UF300 begins running When not using the UF300 remove the jack from the IN connector This extends the life of the battery The SERIAL NUMBER is located at the bottom 2 WARRANTY For our current warranty terms please refer to our website at http Awww behringer com 3 SPECIFICATIONS In Connector 1 4 TS Impedance 500 kQ Out Connector 1 4 TS Impedance 1kQ Power supply 9V 100 mA regulated BEHRINGER
6. trademark owners with BEHRINGER BEHRINGER accepts no liability for any loss which may be suffered by any person who relies either wholly or in part upon any description photograph or statement contained herein Colours and specification may vary slightly from product Products are sold through our authorised dealers only Distributors and dealers are not agents of BEHRINGER and have absolutely no authority to bind BEHRINGER by any express or implied undertaking or representation No part of this manual may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying and recording of any kind for any purpose without the express written permission of BEHRINGER Spezielle Studiotechnik GmbH BEHRINGER is a registered trademark ALL RIGHTS RESERVED 2006 BEHRINGER Spezielle Studiotechnik GmbH Hanns Martin Schleyer Str 36 38 47877 Willich Minchheide Il Germany Tel 49 2154 9206 0 Fax 49 2154 9206 4903 FEDERAL COMMUNICATIONS COMMISSION COMPLIANCE INFORMATION FC BEHRINGER ULTRA FLANGER UF300 Responsible party name MUSIC Group Services USA Inc Address 18912 North Creek Parkway Suite 200 Bothell WA 98011 USA Phone Fax No Phone 1 425 672 0816 Fax 1 425 673 7647 ULTRA FLANGER UF300 complies with the FCC rules as mentioned in the following paragraph This equipment has been tested and found to comply with the limits for a Class B digital device pursuant
Download Pdf Manuals
Related Search
Related Contents
7060 LED - Pelican Cases REVISTA IMPRIMIR.indd Manuale d`uso e manutenzione Cargar MOEN T393 Installation Guide Factory printer service manual Copyright © All rights reserved.
Failed to retrieve file