Home

PCM30U-OCH 6OCH5 Brief description

image

Contents

1. RM1 interface designated as JRM combination of the RM1 interface and the optical line terminal JRMO or a set of two optical line terminals JROO After upgrading the FW in JRO or JROO unit it is possible to connect one or two 2 order multiplexers placed on the unit thus creating various operational variants Among the 2 order contributory streams there is always the 1 order signal of the local multiplexer the other three contributory streams may be external JRMO variant a terminal 2 order multiplexer The JROO variant an intermediate 2 order multiplexer supports the Drop Insert of 64 kbps channels from a chosen 2 Mbps contributory stream the terminating of two contributory streams from a selected direction s and transiting of the remaining contributory streams Apart from the central multiplexer part there are special and standard channel units They are RO3 and ROR units for 50 Hz signal transmission DZP unit for binary state transmission and DO1 and FX units for optical connection of digital protection circuits Standard telephone units of the PCM30U system are used to establish hot line connection or to connect distant subscribers LB UII16K UI16K interconnect 2 wire or 4 wire exchanges EM2P EM4P interconnect 3 wire exchanges KPR2 PKR2 establish an internal UT or an external DIK dispatcher circuit Data units offer the whole range of broadly used synchronous and asynchronous transmission rates from 5
2. Chapter 7 Project and Installation Guide Installing and maintenance works may only be done by trained personnel 6 1 1 Switching Off the System PCM30U OCH subrack may not be switched off at will The equipment may only be switched off with the approval of the dispatcher of the plant or upon a written order If there is more than one subrack in the rack a service engineer or a dispatcher should be present in order to avoid improper handling After switching the PCM30U OCH rack off it is necessary to disconnect the operating voltage 230 VDC that has been connected via cable conductors to the command relay contacts or to the inputs of the transmitting opto couplers 15 C405S970 950 14 N02 6 1 2 Reset All the units in a subrack may be initiated by a software command by pressing the RESET button on the CJAB unit or by switching the subrack off and on again All previous settings will be preserved after a reset except for loops which will be cancelled 6 2 Warranty and Servicing Conditions Warranty and servicing conditions may be regulated either by a special contract or by the general terms below 6 2 1 General Servicing Conditions applicable if not otherwise agreed upon by a special contract Beginning of warranty period Where equipment is part of a turnkey delivery warranty period starts on the day on which construction is handed over to the user If customer user requests to operate equipment prior to taking ove
3. Band 80 MHz 1000 MHz antenna BTA L Scanning Rate 1 5 x 10 dec sec Modulation 80 AM 1 kHz Intensity of Electric Field 10 V m Polarisation horizontal vertical Distance between the Antenna and the Equipment Tested 1m The equipment meets the specification requirements 5 1 3 Immunity against Impulse Burst CSN EN 61000 4 4 1997 Parameters of Generated Impulse Rise Time of an Impulse 5ns Impulse Duration 50 value 50ns Burst Duration 15ms Burst Period 300ms Polarity positive negative Test Duration 60s The equipment meets the specification requirements 5 1 4 Immunity against Voltage Impact Wave CSN EN 61000 4 5 1997 Parameters of Generated Impulse Amplitude 0 5 1 kV Shape 10 700 us series of 5 impacts Polarity positive negative 12 C405S970 950 14 N02 Generator Output Impedance 40 ohms The equipment meets the specification requirements 5 1 5 Immunity against Interference along Line Induced by HF Field CSN EN 61000 4 6 1997 Parameters of Generated Impulse Frequency Band 150 kHz 80 MHz Scanning Rate 1 5 x 10 dec sec Modulation 80 AM 1 kHz Level of Test Field 10V The equipment meets the specification requirements 5 1 6 Radio Interference SN EN 55022B Measurement Parameters Measured at the Distance of 10m Frequency Band 30 1000 MHz Frequency Band 100 200 MHz Frequency Band 150 kHz 30 MHz The equipment meets the specification requirements 5 1 7 Me
4. M interface to Q interface in order to make the PCM30U management compatible with the DPS2000 management At the Q level it is then possible to interconnect RJ units of different localities and to connect them to a management computer with the DORIS software From the point of view of the management each RJ represents a physical address while each PCM30U OCH subrack represents a logical address The control unit is always assigned the logical address 0 Also a PCM30U subrack in classical version containing TLO3 telemetric plug in or a SMJ card loop plug in or the OZ1 OZ2 optical plug ins may be connected to M interface as logical addresses Detailed instructions for use are described in the DORIS SW Manual General Part and in the PCM30U Manual PCM30U PCM30U OCH iii D O R l S F PCM30U OCH CJAB_ PCM30U _ s4 KIO UART 1 XILINX PCM30U OCH M jaa cose M PCM30U network DIK XILINX Figure 5 1 PCM30U OCH Management System 11 C405S970 950 14 N02 5 Technical Specifications 5 1 Electromagnetic Compatibility EMC 5 1 1 Immunity against Electrostatic Impulse CSN EN 61000 4 2 1997 Parameters of Generated Impulse Rise Time of Discharge 0 7 1 ns Polarity positive negative The equipment meets the specification requirements 5 1 2 Immunity against HF Electromagnetic Field CSN EN 61000 4 3 1997 Parameters of Generated Impulse Frequency
5. between 40 and 72 VDC Even short term surpassing the upper limit results in a destructive reaction of input protection circuits Service intervention is required then Redundant power supply units that demonstrate a short term overshoot bigger than 72 V when switched to battery powered mode cannot be used for PCM30U OCH supplying Circuit Protection Supply line 48 VDC or 60 VDC is protected by a 4 ADC circuit breaker In the block input a glass tube fuse is used rated 3 15A F flink An overvoltage accumulation circuit is located behind this fuse having a limited temperature capacity followed by an input of plug in unit NP106 Maintenance During warranty period the equipment is maintained by personnel trained for PCM30U OCH attendance and maintenance and having obtained a service licence valid for the appropriate time period After warranty attendance and maintenance can be performed by trained technicians at customer s discretion training by TTC TTC MARCONI personnel is recommended 5 1 11 Packing Transport and Storing Each device is packed individually in a box with fillers The box is provided with a label carrying appropriate transport marking Packed equipment can be transported by train or by a covered car at the same temperature and humidity conditions as at store The equipment can be stored in ventilated rooms Environment temperature may vary between 20 and 55 C without abrupt changes at relative humidity of max
6. changed the equipment manufacturer should be consulted 5 C405S970 950 14 N02 PCM30U OCH JRO 7 optical cable Q e L JRO PCM30U OCH ETN aS pee amt Figure 2 1 Terminal Multiplexer Variants PCM30U OCH PCM30U OCH ye rc ee Figure 2 2 Redundant Multiplexer Variants PCM30U OCH PCM30U OCH ST por poi MMIL DZP DZP DZP DZP WL DO1 poi MMM DZP DZP DZP DZP Figure 2 3 Path Protection 6 C405S970 950 14 N02 2 2 PCM30U OCH Interface Plug Ins transmission of 4 commands DZP 2x 64 kbps transmission of 16 commands Pes BS 1x 64 kbps phase timing 50 Hz 2 x 03 4x 64 kbps interface DZL SNS 2 x RoR 4x 64 kbps interface REL 1 x X 2x 64 kbps optical interface dig protections 2 x oo 2x 64 kbps ETHERNET 10 Mbps 1x T 1 30x 64 kbps Pel specialized cards E J up to 38 4 64 kbps async sync RS 232 2x 2x 64 kbps Up to 38 4 64 kbps async sync X 21 2x DO5 2x 64 kbps G 703 contradirection 2x Pea 2x 64 kbps G 703 codirection 2x 2x 64 kbps 2 Mbps 64 kbps RS232 RS 422 2x ova 2x 64 kbps 64 kbps X 21 V 36 RS485 2x x21 2x 64 kbps 128 1024 kbps X 21 1x R 2 16x 64 kbps telephone modem 2x umer 2x 64 kbps subscriber interface 2x une 16K 2x 64 kbps exchange E M 2w 2x En 2x 64 k
7. main path failures in one or both directions They inform CJAB units in redundant path by means of PHO signal about the failure All CJAB units then automatically change the channel interconnection in CC to a backup variant that re routes the traffic from main path to the redundant one The number of less important channels may be limited Third and or fourth 2 Mbps signal port can be activated in this variant for connections to the neighbouring network TPR 6 Flexible Multiplexer In this variant the CC functionality can be fully used in equipment having four external 2 Mbps signal ports The equipment can be part of transmission networks of various configurations In one network section including one RJ control unit one redundant ring can be established into which the CJAB unit is connected with its A and B ports Management channel S4 KIO can pass through further C and D ports of another redundant ring of the same network with the other network part being controlled by another control unit TPR 10 PCM30U OCH FW of CJAB unit that is delivered for PCM30U OCH includes operation modes TPR 2 Terminal Multiplexer TPR 3 Redundant Multiplexer and TPR 5 Path Backup Required mode of operation can be selected by switches in the unit These operation modes are recommended for the transmission of commands and protection signals via PCM30U OCH equipment Should another operation mode be required i e FW should be
8. or full redundancy separate transmission of protection signals and external primary streams in the 2 order stream PCM30U OCH also includes 2 order PCM integrated in the equipment 4xE1 or 2xE1 and 2xE2 Cross Connect 1 and 2 order optical line terminal 1 order metallic line terminal DORIS network management system DORIS SERVICE local management system higher EMI resistance protection against unauthorized handling ETSI rack mountable 2 C405S970 950 14 N02 2 Functional Description The central portion of PCM30U OCH comprises NP106 power supply unit CJAB central unit and JR optional HF interface units The remaining part of the equipment accommodates channel plug in units to connect external devices The core of the equipment is a 1 order PCM multiplexer with integrated Drop Insert and Cross Connect functions placed on the CJAB central unit Up to thirty digitized protection or command signals voice and data signals 64 kbps channels from local channel units may be multiplexed into a 2 Mbps stream Cross Connect matrix allows for interconnecting of 64 kbps channels between local channel units and up to 4 external 2 Mbps directions Two of the external directions are terminated on the CJAB unit by RM1 balanced interface the other two directions may be used in connection with the JR interface unit Modularity of the JR unit makes it possible to build up the following variants a variant supporting the 3 and 4 bal unbal
9. signals and adjustable time digital filtering The exact time of the command transmitting is registered in the central part of the equipment and recorded by the management system in its database Less complex then DZP is unit PBS with ability to transfer 16 commands inserted into one 64 kbps channel Opposite of DZP it doesn t check for cable defect and the transmission time is a little extended Unit is designed to operate also stand alone in 1U rack with optionally interfaces 2 Mbps data channels 64 kbps 38 4 kbps 19 2 kbps 9 6 kbps modem Digital protections with mutual communication in the data channel of 19 2 kbps or 64 kbps can use standard electric interface of DO4 RS232 or DOS X 21 V 35 units As regards resistance against outside interference connection over optical fibre is more suitable The DO1 unit with two transmission channels 3 C405S970 950 14 N02 with optical interface is designed for the connection of the 7SD511 512 SIEMENS comparative protections The ABB REL316 and REL551 digital protections in optical interconnection use transmission of 64 kbps channel in a non standardized frame of the 2 Mbps signal The FX unit has been designed to ensure connection to this optical interface having one optical interface it inserts selected data into one 64 kbps channel and transmits their validation over the other one Line protection circuits communicating in 0 3 3 4 kHz voice band can use standard channel units for the
10. type width height depth 6U 480 265 9 242mm Height is given in U height modules a U a 44 45 mm 0 8 mm a module number Rack mounting fix by screwing M5 to M8 into holes in the ETSI rack in the mounting flanges of 19 distance In order to mount the equipment in a 21 rack use two 1 reduction pieces Weight depends on number of plug in units 5 to 15 kgs 190 5 mm 190 5 mm 465 mm Figure 4 2 Mechanical Construction 6OCH Subrack 10 C405S970 950 14 N02 4 Management and Control Control and management of each PCM30U OCH unit is ensured by circuits located on their CJAB plug ins The LED indicators located on the CJAB and JR front panels provide the operating personnel with basic information on the unit s operation and on the functioning of adjacent network sections Within a subrack the plug ins communicate with their CJAB units either via the K serial interface or via IP bus time multiplex S4 NOTFAS bit is used to transmit information within a PCM30U PCM30U OCH network The management channel of each PCM30U OCH unit is terminated at the M interface which makes it possible to mutually connect the management signals of those PCM30U OCH systems within a locality that are not interconnected via 2 Mbps streams At any network point it is possible to connect the RJ control plug in to the M interface in order to manage up to 64 network elements i e the CJABs Beside that RJ control plug in performs conversion of
11. 0 Bd to 1024 kbps using standard types of data interfaces PDK DO4 DOS S64 P64 RK DV24 DX21 The RO3 unit is designed for connection of line comparative protections that on the connective path communicate by the 50 Hz sine signal with 4 wire interface such as S 103B S 105 ZPA Trutnov DLN 910 ABB Accuracy and minimal delay of transmission on a unit for processing of two bi directional 50 Hz signals secures sampling by 16 kHz frequency The minimal phase deviation allows for using the unit also for the phase transmission Doubled sampling frequency means that each signal uses in addition to the Kin channel interval determined by its address unit position the KIn 16 channel interval Technically the ROR unit is derived from the RO3 unit In addition it contains a special complement allowing for co operation of the unit with DZL and DFL comparative protections 2 wire interface produced in the USSR Binary statuses transmission is performed by the DZP unit enabling besides the command transmission also interconnection of distance and sheath protections of EHV line with a relay output contact such as RELZ 100 SIEMENS REL 511 ABB The unit contains four bi directional channels with a high safety level The four channels can be inserted optionally into one or two channel intervals The unit is equipped with communication path failure signaling failure indication of receive and transmit cables level filtering of interfering
12. 85 The environment must be dust free free of chemical influence and vibrations 5 2 Working Safety 5 2 1 General Provisions Valid for the Czech Republic Regular attendance of the equipment may be exercised by an instructed person in the sense of CSN 34 3100 Safety Regulations for Attendance and Work on Electrical Appliances standard after having acquainted himself with the equipment technical documentation e Repairs of equipment may be exercised by a knowing person having specialized electric education according to CUBP 50 1978 standard The equipment is protected against lightning in buildings and thus the requirements of CSN 34 1390 standard are met 5 2 2 General Provisions Valid for other Countries Regular attendance of the equipment may be exercised by a person qualified for attendance of electric appliances up to 1000 VDC in the sense of valid local standards Repairs of equipment may be exercised by a person qualified to working on electric appliances up to 1000 VDC in the sense of valid local standards The equipment is protected against lightning in buildings and thus those parts of standards can be applied valid for working on equipment protected against atmospheric discharges 14 C405S970 950 14 N02 5 2 3 Protective Aids The equipment is designed not to require any special protective aids under normal operation conditions When working on optical units or optical fibres where signals generated
13. PCM30U OCH Protection Signal and Command Transmission System Brief Description TTC TELEKOMUNIKACE s r o T ebohostick 5 100 43 Praha 10 Czech Republic tel 420 234 052 289 234 052 287 fax 420 257 210 385 Doc No C405S970 950 14 N02 2002 Subject to change without notice PCM30U Transmission System PCM30U is a common designation of the following PCM transmission systems PCM30U S S Jo S 8 HIS q PCNSOU 1 and 2 order flexible multiplex designed for universal use in public or private networks implementing all standard voice and data interface types 4x2 Mbps 2x2 Mbps 2x8 D Mbps Cross Connect Ss op me z 1 and 2 order multiplex designed for the transmission of commands and signals of all commonly s used EHV protection types and other voice and data ome om ome signals in the power distribution network i le PCNM30U OCH 9 p 3 Be ll SSS SS IEEE d lais a Chee ate e AO I I Q gle Multiplex designed for one power unit transmision of commands comparative protection phase timing with optional interface 2 Mbps data up to 64 kbps mod
14. PCM30U OCH can use the whole range of PCM30U channel units for the transmission of voice and data The equipment is provided with Drop Insert and Cross Connect functions allowing for interconnecting channels of 64 kbps between local channel units and up to 4 external directions of the 2 Mbps signals By changing the software variant up to 2 of the external directions can be multiplexed to 2 order stream with the possibility of adding other external primary streams 30U OCH synchro Figure 1 1 PCM30U OCH an Example of Application 1 C405S970 950 14 N02 PCM30U OCH supports transmission of up to 20 commands or binary states transmission of commands over 64 kbps data circuit time and voltage filtering of interfering signals cable failure indication command time recording in the management system connecting 4 w comparative protection circuits by 50 Hz signal connecting 2 w comparative protection circuits by 50 Hz signal transmission of phase information for phase matching purposes connecting digital protection circuits having optical or electric interface connecting protection circuits generating voice band signals connecting subscribers and exchanges using all usual interface types establishing internal dispatcher circuits establishing circuits for external dispatcher analogue equipment transmission of data of any common interface types and rates of up to 1024 kbps interconnecting LANs transmission path protection
15. bps exchange E M 4w 2x ema 2x 64 kbps data cards mi om Elle ziluo Ww gt g dispatcher s telephone 1x UT2 2x 64 kbps 2 ne S conference channel 2w 2x DIK2 2x 64 kbps g conference channel 4w 2x DIK4 2x 64 kbps O gt LB telephone 2x TB 2x 64 kbps MB incoming relay set SNS 2x KPR 2x 64 kbps outgoing relay set SNS 2x 2x 64 kbps broadcasting codec 1x stereo 2 28x 64 kbps gt gt DJI ol Broadcasting decodec 1x stereo 2 28x 64 kbps J gt Figure 2 3 PCM30U OCH Interface Plug Ins 7 C405S970 950 14 N02 3 Construction Description PCM30U OCH is supplied in the 19 aluminum subrack of 6U height An unequipped subrack with the backplane is designated as GUOCH The rack offers five positions for the power interface plug ins with the height of 234 mm and depth of 232 mm nine positions for channel units 100 mm high and 160 mm deep and three positions for central units of the same dimensions Mechanical assembly is shown in Figure 4 1 and Figure 4 2 The five leftmost positions are intended for the DZP units Alternatively the first four positions may be occupied by RO3 or ROR units Positions 6 through 14 are designed for DO1 and FX units with optical interfaces for digital protection or for the standard PCM30U telephone and data channel units If RJ unit is employed in the system it should be placed in position 14 and internally connected to the M interface Position 15 accom
16. by laser transmitters can occur it is obligatory to have the equipment switched off or to use protective polarisation glasses The works may not start until the dispatcher determines the date when the equipment may be switched off 5 2 4 First Aid at Electric Accidents With regard to the fact that the personnel can get in touch with the low voltage equipment 230 VAC they must be informed on principles of first aid at electric accidents 5 2 5 Protection against Hazardous Contact The equipment meets the requirements of CSN EN 60950 A1 A2 standard for devices to be connected into telecommunication networks Safety of operation of PCM30U OCH units Electrical Strength of DZP RO2 gt 2kV Insulation Resistance of DZP RO2 gt 50 MOhms 5 2 6 Safety Provisions under Extraordinary Conditions The equipment is provided with special overvoltage protection means With regard to the character of the atmospheric electricity danger the personnel is not allowed to touch metal equipment parts in thunderstorms 5 2 7 Fire Protection Measures New devices will be placed in rooms accommodating existing communication equipment It is recommended to provide these rooms with snow fire extinguishers 6 Installation Warranty Servicing 6 1 Installing and Maintenance Conditions Prior to installing the equipment it is necessary to prepare project documentation For details on a project please refer to the Instructions for Use and Maintenance
17. chanical Tolerance and Climatic Conditions 5 1 7 1 Climatic Conditions The equipment is designed for the stationary indoor use in dust free rooms having fire resistant construction free of chemical vapours having controlled climatic conditions and fire resistant or flameproof floor In accordance with OEG 38 3020 standard Automated Systems of Dispatcher Management of Electricity and Warm Distribution Networks and IEC 57 the equipment meets the requirements of environmental class B4 Operational Temperature 5 C to 55 C Max Rate of Temperature Change 20 C hr Rel Air Humidity 5 to 95 Environment Dustiness 28 g m3 5 1 8 Space Requirements Equipment dimensions are 483 mm x 266 mm x 302 mm 5 1 9 Environmental Requirements follow from the point 5 2 1 13 C405S970 950 14 N02 5 1 10 Requirements Concerning Power Supply Voltage e Power Consumption The consumption differs in dependence on the plug in unit composition in the PCM30U OCH subrack If the subrack is fully equipped with CJAB NP106 3x DZP RO3 units and all the command relays are powered and both LF RO3 channels are driven the consumption is max 20 W then If RO3 unit is not used and command relays are not powered then the power consumption is 10 8 W Eight command relays drain approx 2 W and both LF channels of RO3 approx 7 W Tolerance Nominal power supply voltage is 48 or 60 VDC 15 20 Considering tolerances the power supply voltage may vary
18. e and attendance of equipment serviced by them They shall not provide information of commercial or development nature though they may assist in contacting the responsible person as a rule the Head Project Coordinator Calls aiming at obtaining details for a service intervention shall be without limitation Consultations needed for localization of a defect or for getting acquainted with the service conditions shall be provided at the expense of the equipment user 6 2 4 Service Intervention at Customer s Premises Customer may ask for a service intervention by an engineer of TTC MARCONI Service Department at his premises The request may be communicated by phone or by e mail addressed to Service Department with confirmation by fax in either case If not otherwise agreed upon in a service contract the customer shall be contacted by phone and service intervention shall take place within the next three working days An urgent service intervention may be requested in which case intervention shall take place immediately with extra charge payable even during the warranty period unless otherwise agreed upon in the service contract 17 C405S970 950 14 N02
19. em oS Broadcast codec for the transmission of two POPOL ses EHE stereo channels in the 2 Mbps stream or with e MPEGII via 256 kbps data circuit APS oF ape ome Automatic switch used to transmit external 2 Mbps stream k o fasesss HEE 3 Jd k o MRE dh o tsss EEE A via two paths with the higher quality signal being chosen by the receiving side MT1 5 d p b HDB3 metallic line link suitable for long hauls and for cables nil Ie with intense interference typically for railway ni dea i 4c ow I b P12 Z 1 General Description PCM30U OCH is part of the E1 E2 PCM30U transmission system It is especially designed for the transmission of EHV line protection digitized signals and for the transmission of commands but also voice and data signals in power distribution networks The transmission is realized via optical cables within the primary stream of a higher order system or with external modem via metallic cables The equipment consists of the central part and the channel plug in units allowing for connection of all commonly used line protection types
20. fitting another female connector to the contacts of a channel plug in connector For feeding the system from an external DC power supply with voltage of 48 V 40 V to 72 V it is necessary to connect the faston connectors of the power conductors to the mating counterparts at the backplane The backplane also carries fuses accessible from the front after removing a panel at the subrack upper right part In case of mains feeding it is recommended to use an external power converter 220 VAC to 48 VDC 1 A It is supplied by TTC MARCONI and may be fixed to the back cover or to the DIN strip It is also recommended to back up the mains voltage by a battery All the cabling runs through a passage in the split back cover with cables fixed to a vertical division panel The passage is sealed with a conductive rubber gasket External synchronization is possible by means of 2 048 MHz signal with V 11 interface arriving at the pins of the CJAB module The pins may serve as an input when synchronizing the equipment by an external signal or an output when synchronizing other equipment To set the mode of synchronization the DORIS management software is used Standard channel units may be connected in two ways either by means of common connectors only applicable in non data cards or using a separate cable for each channel position For the data cards it is possible to order output cables card to Canon connector for each card separately If the path pr
21. he telephone contact number stated in the Defective Part s Takeover Report A defect has been localized by a customer s technician who is a holder of the TTC MARCONI s service licence The technician shall draw up the Defective Part s Takeover Report himself stating his name and service licence number and shall hand over the defective parts and the relevant documents to the TTC MARCONI s premises or send them by mail After the consignment is received by TTC MARCONI thirty day repair period starts A defect has been localized by a technician who is not a holder of the TTC MARCONI s service licence During the warranty period such a technician shall be obliged to ask for approval from the TTC MARCONI Service Department for each individual intervention into the equipment and to consult procedure of localizing the defect He shall be sent the form of the Defective Part s Takeover Report by e mail or by fax and he will fill in contact data Then he shall hand over the defective parts and the relevant documents to the TTC MARCONI s premises or send them by mail After the consignment is received by TTC MARCONI thirty day repair period starts Should a service intervention be made without consulting the Service Department warranty repair may not be claimed unless in obvious defects due to workmanship 6 2 3 1 Telephone Consultations TTC MARCONI Service Department shall only provide information necessary for the operation maintenanc
22. modates NP106 power supply unit position CJAB central unit and position 17 JR interface unit As there are 14 positions for channel units only channel position No 9 is omitted Two RM1 interfaces of the CJAB unit are accessible from the back on CANONOM connectors at the backplane The other two RM1 interfaces are accessible from the front on RJ45 connectors located at the front panel of the JRM interface unit FC PC optical connectors are located on the front panel of the JRO JROO unit and also on the front panel of FX channel unit while DO1 unit is furnished with SMA optical connectors CANON15M connector at the back of the backplane is used for mutual interconnection of two pieces of equipment in fully redundant operation The cabling of power interfaces is terminated at the back Each conductor may be easily and quickly mounted using screw terminals screwable along the center line of the conductors After fitting the terminals to external cabling the conductors run through the passage in the back panel and connect to the mating counterparts of the DZP or RO3 ROR plug in The same procedure is applied when mounting the conductors of the alarm relays using a terminal located at the backplane Channel plug in outlets are accessible from behind by means of two horizontally positioned high density connectors at the backplane The connectors have extended contacts enabling an alternative connection of external cabling by wire wrapping or by
23. of Installation Mounting and Maintenance 6 2 2 Software Warranty To make a claim on software customer must present the software product including licence agreement The warranty shall not cover service works ordered by the customer that indicate proper function of the manufacturer s products but indicate failures of any other product not being serviced by TTC MARCONI 6 2 3 Procedure in Case of a Defective Plug in Unit Repair of a plug in unit shall not be carried out by way of exchanging units Customer is supposed to have adequate store of spare parts Parts manufactured by TTC shall as a rule be repaired within 30 days from the issuance of Defective Part s Takeover Report If a plug in unit proves to be non repairable 16 C405S970 950 14 N02 customer shall be invoiced costs of ascertaining the defect and shall be given an offer to buy a new part In order to claim a warranty repair the defective part must be accompanied with a copy of a document proving that the part is still in the warranty period Procedure A defect has been ascertained by a TTC MARCONI s service engineer The service engineer shall propose to take over the defective part for the repair and shall issue a Defective Part s Takeover Report to the customer After thirty days the customer may pick up the repaired part in TTC MARCONI s premises or if the part has not been repaired claim a new one If a part is unrepairable the customer shall be notified to t
24. otection mode is employed it is necessary to interconnect the two subracks mutually protecting each other with 427K487 cable At the back of the backplane there are several pairs of pins for the setting of operation modes of the subrack and of individual cards For details please refer to User s Manual Construction of the system conforms to EMC standards The equipment has modern design with a logical layout of controls and LED indicators A lockable power supply switch at the front panel prevents 8 C405S970 950 14 N02 unauthorized access The system has a socket to connect a telephone set and supports hot line calls if UII16K module is used and placed in position 14 D JP ire g E p PCNASOU OGH Q D JP S S op D ag IQ 19 QIQ RO3 ROR DZP RO3 ROR DZP RO3 ROR DZP NP106 and CJAB modules required for the system to be operational JR Interface Module optionally 2 Mbit s or 8 Mbit s KJ6 to KJ15 optional PCM30U channel modules 4 1 PCM30U OCH Front View a Completely Equipped System 9 C405S970 950 14 N02 3 1 Mechanical Construction Parameters Mounting flange hole spacing 465mm x 190 5mm Basic subrack dimensions
25. r the construction the customer user shall ask for the warranty to take effect In such a case the warranty period shall last for 24 months following the delivery of equipment Operation of equipment shall mean full operation with subscribers Using equipment for measuring or testing purposes or for training of personnel shall be without limitation Where only the delivery of equipment has been ordered without installation commissioning etc the warranty period shall start on the day of equipment sale Handling and servicing equipment during the warranty period If equipment is used in a power utility network for the transmission of commands and protection signals over EHV lines only duly trained and authorized personnel may handle the equipment Such personnel may handle or reconfigure the equipment but a warranty service intervention shall only cover original configurations or individual plug in units During the handling of equipment the rules described in chapter Operation and Maintenance of Equipment must be observed e The warranty shall not cover the following Defects following from improper handling Defects following from inappropriate storing during which instructions described in chapter Packaging Transport and Storage have not been observed Natural disasters out of control of the manufacturer such as fire flood atmospheric electricity discharges Installation failing to observe rules described in chapter Conditions
26. rks the producer recommends to use equipment only in the terminal operation between two points for transmission of protection commands and signals Transmission reliability can be increased by doubling the transmission path between PCM30U OCH stations or by the redundant transmission over two parallel sessions From the point of view of management network synchronization and other telecommunication channels transmission it is suitable to connect equipment to transmission networks of various structures using different external directions of the 1 and 2 order signals so that a failure in an adjacent network does not endanger the basic transmission of protection commands or signals The mechanical structure used with guaranteed EMI resistance as well as circuit solution enable faultless operation even in strong interference environment High reliability is also ensured by temperature ageing seasoning and proper testing of each unit in manufacturing The equipment manufacturer supplier offers comprehensive services engineering consultancy projecting installation warranty and post warranty servicing 2 1 Operating Modes The CJAB unit is supplied with optional FW that defines the plug in unit operating mode It also determines various operational types of PCM30U OCH PCM30U or APS equipment Following types are available TPR 1 switch of streams TPR 2 terminal multiplexer see figure 2 1 TPR 3 redundant multiplexer
27. see figure 2 2 TPR 4 intermediate multiplexer TPR 5 path back up see figure 2 3 TPR 6 flexible multiplexer TPR 1 Switch of Streams This type of operation enables transmission of protected E1 external signal in parallel over two separate transmission paths and choice of a signal from the better quality path by the receiving end TPR 2 Terminal Multiplexer Basic application that connects channels from the channel units placed in identical positions of opposite stations 4 C405S970 950 14 N02 TPR 3 Redundant Multiplexer Transmission of the 2Mbps stream local signal from channel units over two separate paths In the basic setting the whole stream is doubled but it is also possible to select function using CC which allows for redundancy of only the selected 64 kbps channels TPR 4 Intermediate Multiplexer An equipment variant with two external directions enabling termination of selected channels and transiting of the others Channel selection can be changed by control system command The equipment can be included in a redundant ring with automatic channel redirection in case of failure of any section TPR 5 Path Backup Redundant operation of two paths realized with PCM30U OCH Both ends are interconnected by a cable transmitting 2 Mbps signals and PHO failure message One of both paths is set as main one by means of jumper in CJAB whereas the other one as redundant CJAB units in both ends evaluate
28. transmission of two telephone channels the EM4P and EM2P units are used for 4 wire and 2 wire transmissions respectively These units can also be used for the transmission of other voice band signals such as those of modems or voice frequency carrier telegraphy DORIS 2000 NET software the management system of PCM30U OCH equipment is a universal management system designed for all transmission systems manufactured by TTC In the network of mutually connected PCM30U OCH PCM30U stations the management channel is transmitted in the S4 service bit of the KIO channel interval The management channel is in every PCM30U OCH equipment terminated by the M interface that within one locality enables management interconnection of those PCM30U PCM30U OCH devices not being interconnected by 2 Mbps streams Anywhere in the network is it possible to connect the RJ control unit for the controlling of max 64 network elements represented always by a CJAB unit to the M interface The DORIS management system is compatible also with the former version of central units using the TJ telemetric units The RJ unit as the M interface Q interface converter mediates connection to the PC serial port The DORIS SERVICE program enables local management of one PCM30U OCH equipment the DORIS 2000 NET network management of up to 32 local RJ control units and theoretically up to 254 local and remote RJ units per one DORIS interface As for the power distributing netwo