Contents
1. 10 3 While one person is holding the column remove the plastic package from the Body and scale 4 Incline the body part of the device about 10 20 in the arrow direction as shown in the picture for connection between scale harness and scale PCB gl Please pull out scale connection harness from the hole of the lower part of the body and connect it to the scale PCB which is on the reverse side At this moment the person who supports the body has to hold it tightly so the other person who assembles it does not get hurt Scale harness 6 After connecting the scale harness and the scale PCB stand the body up One person screws 2pcs of M8 bolts in the left and right side of the body using 5mm L wrench while the other holds the body as shown in the picture F EN 1 A il pS 12 4 Assembling the body cover Push the body cover in the arrow direction shown in the picture below and adhere to the scales packing How to adhere T3 5 Adjust the level amp Turn on the power Check the level of the device If it is not at level adjust the level using the four wheels After adjusting the level connect the provided adapter and power cable and turn on the device lf you press the power saving button on the right side of the column as shown in the picture it turns to power saving mode Power saving button Water drop Horizontal normal meter Adjusting wheels 7
2. EAST ASIA EU and etc Abdominal Analysis Abdominal fatness is divided into subcutaneous type and visceral type When it comes to body fat experts say that not only the amount of fat is important but also its distribution If visceral fat area is over 100 cm it is classified as visceral obesity regardless of P B F W H R or Body weight Waist to hip ratio W H R shows the distribution of fat stored in one s abdomen and hip It is simple but useful in assessing fat distribution Body fat is stored in two distinct ways They are often categorized into and called apple and pear type Apple type shows bigger girth of waist than hip and pear type has bigger girth of hip than waist If body fat in abdomen increases the risk to cardiovascular diseases diabetes etc becomes higher 1 W H R Waist to Hip Ratio W H R is calculated by dividing waist girth by hip girth When W H R is below 0 9 male 0 85 female the risk of visceral obesity is low 2 Visceral Fat Level The degree of visceral obesity is displayed in a level Level 1 4 corresponds to subcutaneous fat type Level 5 8 corresponds to balanced type that subcutaneous and visceral fat is balanced Level 9 10 corresponds to borderline type If subjects maintain current lifestyle they will proceed to visceral fat type Level 11 15 corresponds to visceral fat type Level 16 20 corresponds to visceral fat type ll 3 VFA Visceral Fat Area Th
3. flickering 3 Printing Waveform printing possible Pass Fail Model X SCAN PLUS 950 92 Service center TEL 82 2 587 4056 82 53 856 0993 lf the problems continue call the service center When you ask for service the manufacturer s label serial number date of Original purchase and explanation of malfunction will be required x For purpose of improvement specifications and subject to change without notice FACTORY 29 Gongdan 4 ro Jillyang eup Gyeongsan si Gyeongsangbuk do Korea TEL 82 53 856 0993 FAX 82 53 856 0995 EUROPEAN REPRESENTATIVE VITAKO Sp z 0 0 UL MALEJ SYRENKI 2 71 790 SZCZECIN POLAND TEL 91 8522900 901 FAX 91 8522910 JW XP950E 20151104 Rev4 0
4. value of weight components Body Weight Lean Body Mass Mass of Body Fat Lean Body Mass Soft Lean Mass Mineral Mass Soft Lean Mass Total Body Water Protein Mass Total Body Water ECW Extra Cellular Water ICW Intra Cellular Water The sum of intra cellular water and extra cellular water is the total amount of body water Soft lean mass consists of total body water and protein mass Lean body mass consists of soft lean mass and mineral mass Ultimately the sum of Lean body mass and Fat mass is weight oo D Weight Subject s body weight Std wt Standard weight height m 2 X 22 BMI 2 L B M Lean Body Mass It is calculated by subtracting mass of body fat from body weight Lean body mass consists of fat free mass of body such as muscle organs blood and water 3 Mass of Body Fat It is calculated by subtracting lean body mass from weight Subcutaneous Fat It exists under our skin and when pulsing with visceral fat it becomes the total mass of body fat 4 S L M Soft Lean Mass It consists of total body water and protein and some internal organs such as heart stomach and bowels etc S M M Skeletal Muscle Mass Skeletal muscle is also called voluntary muscle because one can move this muscle voluntarily unlike visceral muscle Skeletal muscle enables people to walk and perform other voluntary activities 5 Mineral Composed of bone and electrolyte 6 Protein Major component
5. 1 99 years old Operation ambient Ambient temperature range 5 to 40 C Relative humidity range 15 to 93 non condensing Storage ambient Ambient temperature range 25 to 70 C Relative humidity range lower than 93 RH x For purpose of improvement specifications and design are subject to change without notice 67 Name of product Body composition analyzer Name of model X SCAN PLUS 950 Serial number Period of warranty Date of purchase Within 1 year from the date of purchase Name Tel Customer Tel When you receive this warranty make sure that the name of the dealer and the month day and year of purchase are all completed This warranty will not be reissued please keep it in a safe place 68 1 How to install a device To ensure the operators security please work in team of minimum two people during installation packing and transport 1 Components 5mm 6angles wrench M8 bolt Main unit A ee ee ee Body cover 2 Unpacking 1 UP mark should be indicated on the top side of the box when you place the Carton box on a surface CARTON BOX 69 3 After opening the Carton Box fold the box cover outwardly not give contact to the air pack for protecting products Take out the protection air pack and check its components inside Air pack 3 Installation 1 More than two workers hold the device and lift it up Take the device out of the Carton Box
6. Input Height The following message and voice guidance appears as follows Input your Height i 7 l tt Licm The user enters height on the touch panel e button on touch panel for decimal point numbers Input your height If want to re input height the first written value is first removed ex when 135 4 Is input 154 cm appears on LCD ex when 1395394 is input 594 cm appears To input decimal number touch button ahead of decimal number ex to input 160 8 input 1 gt 6 gt 0 gt gt 8 but if wanting to adjust to 160 4 input only e gt 4 Input Age The message appears as follows Input your Age Voice guidance also announces this message Input your age and confirm it Input your age Select gender The LCD screen changes as shown in the picture with Lt yrs zal 12 Select your gender a chime bell When the user hears the voice guidance Select Male or Female select the gender 47 Start measurement After inputting the subject s personal data the screen changes as shown in the picture Fit feet on plate electrodes accurately When an ankle electrode is used Check whether the ankle electrode is selected in the SYSTEM SETUP mode Make sure that your ankles are closely touched on the electrodes until the measurement finishes Users are allowed to measure up to 3 times only when the connection between ankles the electrode is bad D
7. L R left right to fit to the pre formatted result sheet Select E PRINT POSITION on SYSTEM SETUP screen and press SET on touch pad Pre set 00 for U D and 00 for L R Range 99 for U D and 99 for L R Choose U D by pressing V A on touch pad Choose L R by pressing gt lt on touch pad Pressing button moves print position down or right Pressing lt button moves print position up or left Every single press moves print position by about 0 2 mm Press SET button on touch pad to save it Return to SYSTEM SETUP screen by pressing CLOSE button on touch pad 1 L R left right is moving to the left and is moving to the right U D up down is moving up and is moving down 2 The print position needs to be separately set on the result sheet for Body composition analysis and Segmental analysis each Press BCA and adjust the print position of Body composition analysis result sheet and then press SET button to save the setting Press SEG and adjust the print position of Segmental analysis result sheet and then press SET button to save the setting It is possible to adjust the print position of the result sheet for children if you press the CHD button 34 lt CLOTHES gt lt is to subtract the weight of clothes worn by the CLOTHES subjects from measured weight Calculated value from this setting is used in body composition analysis as subject s weight Sel
8. Set correct date and time in the same way Press SET on touch pad to save the change Return to SYSTEM SETUP screen by pressing CLOSE on touch pad 1 If SET button is pressed before finishing setup of date and time the date and time inputted at that time is saved and SYSTEM SETUP screen appears To cancel any changes attempted press CLOSE then this device saves the previous date and time and SYSTEM SETUP screen appears 2 When software is used in data management measured date is automatically saved as the date set in this device Therefore the date and time set in this device should be checked before use lt VOLUME gt It adjusts the volume of voice guidance VOLUME Select EJ VOLUME on SYSTEM SETUP screen with VY A button and press SET on touch pad tit Pre set 3 Range 0 9 ES Adjust volume with V A button on touch pad Press SET on touch pad to save selected value Return to SYSTEM SETUP screen by pressing CLOSE on touch pad Ss lt PRINT gt It selects the printing mode of the A4 printer Select E PRINT on SYSTEM SETUP screen and press SET button on touch pad Pre set AUTO Choose one button on touch pad Press SET button on touch pad to save it Return to SYSTEM SETUP screen by pressing CLOSE button on touch pad lt PRINT POSITION gt It adjusts the printing position in the direction of U D PRINT POSITION up down and
9. Try to measure again after cleaning the electrode holders with soft gauze e Try again after cleaning the hands and soles e Check if foreign materials are between electrodes and measuring parts e Try again in correct posture and hold the electrodes according to the measuring method e make sure that the electrode holders are connected to the main body well e If the same error occurs even after connecting the electrodes well please contact with company or its local distributor from where device is purchased 64 1 AFTER SERVICE Or there is any problem with the unit please follow the steps below x Contact our company s Overseas Service Department immediately After gathering the model name Serial Number date of purchase and description of the problem contact our company with information shown below x Try to solve the problem over the phone with the personnel of local service department lf the problem cannot be solved over the phone return the unit directly to service department x Our company or local distributor will make available on request circuit diagrams component part list descriptions calibration or other information which will assist your appropriately qualified technical personnel to repair those parts of the unit which are designated by our company as repairable How to contact our company Write us at Jawon Medical Co Ltd 29 Gongdan 4 ro Jillyang eup Gyeongsan si Gyeongsangbuk do
10. advice provided by your own physician or other medical expert You should not use the information contained in the product for diagnosis or treatment of health problems or prescription of medication by yourself If you have or suspect that you have a medical problem consult with your physician promptly Defective units or accessories must be packed in the replacement cartons to be shipped off from you to our company Shipping and insurance costs for return of defective unit must be prepaid by the users Measurements may be impaired if this device is used near televisions microwave ovens X ray equipment or other devices with strong electrical fields To prevent such interference use the meter at a sufficient distance from such devices or turn them off Incorrect operation or failure of user to maintain the unit spares the manufacturer or his agent of the responsibility for system s non compliance with specifications or responsibility for any damage or injury This manual is made for informational purposes and this manual and product are not meant to be a substitute for the advice provided by your own physician or other medical expert You should not use the information contained in the product for diagnosis or treatment of health problems or prescription of medication by yourself If you have or suspect that you have a medical problem consult with your physician promptly Defective units or accessories must be packed in the repla
11. device as To start the measurement a scale so it will not start to analyze body composition please step on the scale If you long press button from 3 5 seconds again the mode will be changed to BCA mode 41 versus ano anna 1 Precaution for measurement The reliability of the results can be assessed by its accuracy The Accuracy of the device is determined by comparing the actual body composition and the results from Body Composition Analyzer The Reproducibility is determined when the device gives the identical results under the same conditions In order to maintain the accuracy of the results the following guidelines should be kept 1 Water volume increases after a meal Therefore measure on an empty stomach Measure 3 4 hours after a meal Avoid beverages containing caffeine or beverages functioning as diuretics 4 hours before measurement Drink 2 cups of water 2 hours before the measurement 2 Before measurement the subject should be in a stable condition Measure 3 4 hours after a bath a sauna exercise or activity that sweats a lot Or measure before these actions 3 Avoid drinking alcohol 24 hours before the measurement 4 Wear clothes as light as possible 5 Once the subject is on the scale avoid sudden movement from sitting to standing position Body fluid goes down to the lower body and affects the results Thus subjects should be measured after maintaining standing position
12. devices with strong electrical fields To prevent such interference use the meter at a sufficient distance from such devices or turn them off Do not disassemble or alter the device under any circumstances as this could result in electric shock or injury as well as adversely affect the precision of measurements This device is specified as Class 1 type BF unit under the standard EN 60601 1 2006 Basic safety and essential performance of Medical Electrical Equipment Therefore patients must not touch or handle inner side of the system at any time Do not to touch signal input signal output or other connectors and the patient simultaneously The unit has previously been adjusted in the factory for optimum performance Do not attempt to adjust switches or any other things except those specified in this manual for operation Never pour any liquid directly on the scale platform as it may leak and cause internal damage Never jump on the Weighing Platform there may be a risk of stumbling and malfunction of the equipment This equipment has been tested and found to comply with the limits for medical devices according to IEC 60601 1 2 2007 These limits are designed to provide reasonable protection against harmful interference in a typical medical installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to othe
13. input basic information before the test starts 2 If FLASH MEMORY is selected the results are saved in flash memory in the machine itself If USB MEMORY is selected the results are saved in portable USB memory stick 1 When FLASH MEMORY is used 1 Up to 100 000 results can be saved If the number of saved results exceeds 100 000 the new result will overwrite the oldest result The results can be deleted and initialized 2 The result sheet can be printed from an A4 printer 2 When USB MEMORY is used 1 The number of storage differs depending on the capacity of USB MEMORY 2 The A4 result sheet cannot printed 3 The user should use USB memory option supplied only from our factory Problems caused by USBs which users randomly purchase are not subject to the manufacturer s responsibility 37 lt CHILD ADULT AUTO gt It selects the print format of result sheet CHILD ADULT AUTO Choose 135 and on the initial screen of SYSTEM SETUP to enter the menu Pre set AUTO Select a print format with the touch pad Press SET button on touch pad to save it Return to SYSTEM SETUP screen by pressing CLOSE button on touch pad 1 The print format of result sheet 1 CHILD No matter what age is set it prints the result sheet for CHILD Only the child growth curve is not printed in case of 18 or over 18 2 ADULT No matter what age is set it prints the result sheet for ADULT The child growth perce
14. lean mass the higher the score is oY Study Impedance It indicates the segmental impedance of five body parts left and right arms left and right legs and trunk corresponding to each frequency 1 1000 kHz Blood Pressure When the blood pressure monitor supplied from Jawon Medical Co LTD is connected to the device blood pressure can be measured and the result can be printed out Systolic blood pressure diastolic blood pressure and pulse are printed on result sheet It helps to recognize hypertension assessment related to obesity QR code scan the QR code with a smart phone to see the result on the website 60 E es 1 Pay attention to the allowable value of electric current 2 Avoid direct sunlight humidity dust thick oil and salty environment or extreme changes in temperature S 3 Do not install or store the device in a place where any chemicals or gas are stored 4 Do not use the device in any unstable vibrating or impact giving area 5 Connect the earth placed on the backside of this device to terminal plate to prevent any electric shock from leaking current or a potential difference 6 Do not put or drop anything on the device and avoid strong impact 7 Do not disassemble or remodel the device 8 lf this unit has not been used for a long time use this after confirming with an expert if all function and appearance are in good condition 9 Do not splash any fluid on this device or insert any for
15. meter og lt QR CODE DOMAIN gt This is for setting QR code domain Select E to enter the menu Enter a domain address or IP you want on the touch pad maximum 20 digit number can be entered for the domain address Press DONE button to save the data and return to the initial screen Once you scan QR code after a measurement the data will be stored in the server of the saved domain address If the domain address is not set the data will be stored in the server of Jawon Medical m jawon com You can search the measurement data by creating an ID and PW 40 Once turning on the device you can see the screen same as right picture To start the measurement 1 ID search please step on the scale Press Exe button on the initial screen Enter a 20 digit ID with alphabets and numbers mixed and press Exe button You can see the results of the ID or print them An ID can be searched when ID USAGE is set in YES 2 INDEX search In case of not using ID INDEX search can be used on the left upper side of the screen Press ID on the screen and enter an index number and press can search or see the results and print them button Then you 3 Setting a measurement mode Users can select one of SCALE and BCA modes Long press button for 3 5 seconds then the icon will change to EA sue and you can use the device in SCALE mode In this case you can only use the
16. range of body fat Out of range of measurement Insufficient electrode connection to Ankle e Clean the measuring parts the electrodes When the subject s body palms and soles and try again impedance deviates from the limit Measure again with correct posture Insufficient touch to electrodes e Do not move during measurement Impedance is out of range e If the same error is repeated please contact Range 100 950 Q our company or its local distributor from where this device is purchased e Clean the electrode holders and try again e After checking that there is neither something with wrong input of personal data When the subject s P B F age gender nor with measuring error of deviates from the limit weight and impedance try again Incorrect input of personal data e lt can t measure if the P B F is out of range P B F is out of range e When the same error occurs even after re measurement please contact our company or its local distributor from where the device was purchased e Input height correctly or if installed height already measure again e Confirm to measure weight and try again correctly When the subject s fatness is Saa e It can t measure if the fatness is out of deviated from the limit range Mechanical error e When the same error is occurred even re measurement please contact with our company or its local distributor where is purchased e When even one of all 4 electr
17. 3 ABOUT BODY COMPOSITION TTT re ee eT Ce A Ee A Te ee ee ee A er Te ee eee ere ee 18 TERM AND FUNCTION OF EACH PART Te cre eT 0 a ee ee eT ee ee E ee a ee a 20 1 Basic Package e ee ll a ee ee ee ae ee a a ee 20 2 Options Sn 21 3 Appearance of the device o cc i ce A A E 23 4 Term of each parts and its function 1a ee ae ee ae ee ee 24 INSTALLATION Trt TT Cee ee A E AA A A AA ee A A A A A 27 1 Power Supply o 27 2 Peripheral Device Installation Ter Te Te E E E E AEEA EELEE er ee 28 1 Connecting Computer o ss 28 2 Connecting Printer ToT A ee ee ee 28 3 Connecting Blood Pressure Monitor ithe o a a A eee ee ee ae 29 4 Connecting ultrasonic height meter Tree eT eT ee ee ee ee ELELEE ee ee er eee re 30 SYSTEM SETUP A er re ee eee AR ee ee eee A A ee RA AAA 31 1 Sorts o E O A 31 2 Entering SYSTEM SETUP 60 a a 0 eae 0 a ae a a a 31 3 Entering MENU view a ter Tee a ee LEE ETT EEE LOR EC CLEC Ee CUP CELE CCT ECE ee Lee ee 31 4 How to move into SYSTEM SETUP RR Tce Tere eT ER AAA ee ee ee ee ee 32 5 How to escape from SYSTEM SETUP eT rre CeCe Te eC ET Le Cee LC ECC CLEC Eee Te Cee Te race ee 32 6 Setup a 33 INITIAL SCREEN SETTING a 41 MEASUREMENT AND ANALYSIS a 42 1 Precautions for Measurement dc e ld ELL O a EE EELEE ld 42 2 Correct Posture a 43 3 Measuring Procedure Terr re ee A A AAA A 46 1 Basic Analysis a a A A A 46 2 Procedure using Height Meter EE A EEOC TEE CEL ee TR eR A E ee re et ee ae oor 50 3 Proced
18. 4 2 Assembling an Bluetooth option Connect the provided Bluetooth to the BLUETOOTH port on the back side of the device Users can check and manage the result data on the exclusive mobile device app via Bluetooth connection 1 Components for Bluetooth Union of bracket v Bolt Cable 2EA grand Antenna 2 Unscrew the bolts 2EA and cable grand 1EA with a driver Keep the separate bolts 2EA and cable grand 1EA to assemble a bracket and cable later es Connect the antenna to the Bluetooth Connect the main body connecting cable to the reverse side of the antenna and fix the cable by screwing the bolts in with a driver 4 Connect the unconnected side of the cable to EXTERNAL PORT on the back side of the main body and then switch on the Bluetooth 10 5 Fix the Bluetooth to the back side of the main body with the provided bracket using a driver The installation is completed by turning on the device Joint of bracket ce 3 Assembling an ultrasonic height meter option When installing packing and transporting please work in teams of minimum 2 people to ensure safe operation 1 Components for installing an ultrasonic height meter 5mm 6angles wrench y a SRS ag Ao It at op harne f UHM Lower body Upper body y 4ea of M6X12 wrench RS 232C cable bolt a dd dl e Pl 2 Assembling the lower body Put the bot
19. BODY COMPOSITION ANALYZER X SCAN PLUS 950 User Manual Leading Health Trend Body Composition Analysis Intra Extra Cellular Water Total Body Water Protein Mineral Body Fat Mass Prediction of Abdominal Fat Fatness Abdominal Analysis WHR Waist to Hip Ratio Visceral Fat Level Visceral Fat area Subcutaneous Visceral fat mass Body Type Percent Body Fat BMI Body Mass Index Table of Body Type Energy Expenditure BMR Basal Metabolic Rate TEE Total Energy Expenditure Segmental Assessment Edema Assessment Target to Control Impedance Age Matched of Body Blood Pressure Es The device bears the CE label in accordance with the provisions of Medical Device Directive 93 42 EEC THE PERSONS RESPONSIBLE FOR PLACING DEVICES ON THE EC MARKET UNDER MDD 93 42 EEC Jawon Medical Co Ltd 29 Gongdan 4 ro Jillyang eup Gyeongsan si Gyeongsangbuk do Korea TEL 82 53 856 0993 FAX 82 53 856 0995 EC REP VITAKO Sp z 0 0 UL MALEJ SYRENKI 2 71 790 SZCZECIN POLAND TEL 91 8522900 901 FAX 91 8522910 NOG TONE E E E an Sni nan 5 o U E seser aceenncsiecrrsec aflanna lan nadi 5 2 WORD DEFINITION Soo 5 3 CLASSIFICATION AND COMPILIANGE 234 att n dad 6 4 SAFETY PRECAUTION PP A 6 5 SAFETY SYMBOLS AND INFORMATION cccccccsssseeceeeceeeeeeeeeeseeeeeeee hrak kk krk 11 6 Guidance for Electromagnetic compatibility EMC oooonccncccccncnncccnoncnnnnoncnnnnononnnoncnnonononnnos 1
20. It is easy to input data 2 Body Part 1D Holders of Handle electrode Handle electrodes are rested on the holder when they are not used 2 Start button Press Start button with your thumbs to start the measurement 3 Handle electrodes lt measures the resistance of body Hold them with both hands during measurement 4 Cable lt connects the handle electrodes from the Circuit Board Subsidiary Switch If you press the subsidiary switch while the device is on standby it turns to the power saving mode 24 3 Base Part Scale Measure weight 2 Plate electrodes The user should step them in bare feet 3 Horizontal level A level to regulate horizontality of the analyzer Body cover It covers the joint between the base and body parts 4 Wheels support the analyzer Regulate the level of the analyzer by driving the wheels either left or right 4 Rear Part DD COMPUTER A port to connect computer with USB Cable 2 EXTERNAL Connecting the peripheral devices Bluetooth etc 3 PRINTER A port to connect printer 4 BLOOD PRESSURE A port to connect blood pressure monitor manufactured by Jawon medical HEIGHT A port to connect ultrasonic height meter 6 Adapter port Connecting the adapter Power switch lt can be used to turn on off the power A window in the rear part of this analyzer is designed to be opened by an authorized technician to check the
21. Korea TEL 82 53 856 0993 FAX 82 53 856 0995 You can also contact the following representative or your local distributor 2 PACKING AND TRANSPORT Our company wraps this device up with the most suitable method to protect it from any impact or damage during shipping and transporting This device can be damaged during delivery if it is packed in other ways except the one our company uses Please handle this device carefully without any impact in packing and delivery If this device needs to be transported wrap this device up again and transport it as follows Turn off the power 2 Turn off the power of the peripheral devices and disconnect all cables 3 Disassemble the device in reverse order of assembly 4 Pack the device with the original packing materials Transport it carefully 65 Result contents Body Composition Result Weight Standard weight Lean body mass Mass of body fat Subcutaneous fat mass Skeletal muscle mass Soft lean mass Protein mass Mineral mass Total body water Intra cellular water Extra cellular water Body mass index Percent of body fat Ratio of E C W T B W Waist to hip ratio Visceral fat level Visceral fat mass Visceral fat area Prediction of abdominal fat Target to Control Control of Body fat Control of Soft lean mass Control of Weight Body composition change 8 times of Ratio of E C W T B W Percent of body fat Soft lean mass Weight Segmental dual graph of soft lean ma
22. S This device is designed and manufactured with consideration of the safety of the operator and subject and also the reliability of the unit The following warnings precautions and notes must be observed for safety During measurement of the body composition a microcurrent of 180uUA flows through the body Individuals who have any kind of implanted active medical devices such as pacemakers should not use this equipment because the microcurrent can cause malfunction in the implanted device To prevent fire hazard use only a correctly wired 100 240VAC outlet and do not use a MSO Multiple Socket Outlet that is not in compliance with IEC 60601 1 To reduce the risk of electric shock or product damage never plug in or plug out with wet hands Physically disabled persons should not attempt to take measurements alone but instead should have their caretakers assist them in using the device The unit must be operated only by or under supervision of a qualified person with our company or our distributors If you have experienced any trouble with the unit switch it off immediately and contact our company or its authorized dealer for assistance If you plan to connect any device from other manufacturers electrically or mechanically to the unit contact our company or its authorized dealer for instructions before doing so When you connect computer or other system to the unit RS 232C the attached systems should be those certif
23. Start measurement The screen changes as shown in the picture Grip electrode handles correctly and press start buttons with thumbs at the same time Impedance measurement starts by pressing start buttons Do not move or speak during measurement Measuring LCD turns to MEASURING view Voice guidance announces Starting measurement don t move or speak please Grab the handle LCD indicates how the electric current flows into our body 48 Finish measurement and Result As the measurement completed the message and voice guidance informs the user Scanning QR code Press the QR code on the device screen to enlarge the icon and scan the QR code with a mobile device to save the data in the server After scanning the QR code you can check the measurement data with your mobile device and manage it at will from the server in which it is saved 1 Scan the QR code with a QR code reader in a smart mobile device 2 The data saved in the server could be damaged or lost due to a problem with the server 1 Restarting Once the result is displayed on the display it can be printed out in pre printed result sheet After confirming the analyzed result press Initial view to restart The device returns to the initial screen after one minute 49 2 Using Ultrasonic Height Meter An Ultrasonic Height Meter is an optional part When height meter is connected to X SCAN PL
24. TE TYPE Select E DATE TYPE on SYSTEM SETUP screen and press SET button on touch pad Pre set YY MM DD Choose the format on touch pad Press SET button on touch pad to save it Return to SYSTEM SETUP screen by pressing CLOSE button on touch pad lt Communication gt Select the connecting method CABLE is for USB cable and WIRELESS is for wireless communication Select BB COMMUNICATION on SYSTEM SETUP screen and press SET button on touch WIRELESS CABLE WIRELESS SELECT pad Preset CABLE Choose CABLE or WIRELESS on touch pad Press SET button on touch pad to save it Return to SYSTEM SETUP screen by pressing CLOSE button on touch pad 36 lt ID usage gt ID USAGE can be turned off or on Select Bo usage on SYSTEM SETUP screen and press SET on touch pad FLAG Preset NO FLASH MEMORY USB Memory ID USAGE Choose ID USAGE on touch pad Choose YES or NO on touch pad SAVE DEVICE From SAVE DEVICE select either FLASH MEMORY or USB MEMORY to save the analysis If ID usage is USB memory activated an up to 20 digit ID can be input and saved in FLASH memory or Press SET button on touch pad to save tt Return to SYSTEM SETUP screen by pressing CLOSE button on touch pad 1 If ID function is activated ID window will pop up at the initial screen So the user can input ID and save the results If ID function is not activated the user should
25. US 950 it measures the user s height in accurate way Measuring procedure Connect X SCAN PLUS 950 to ultrasonic Height Meter 2 Turn on the device and height meter After the voice guidance To start measuring weight step on the scale 3 The LCD monitor of height meter moves to the height of the user with a message Measuring height Fix your eyes on the LCD approximately 5 seconds Measurement starts with message Look at LCD 5 When the measurement completed it displays the result of weight and height on the LCD With chime bell you can start inputting the person data Q The rest of the procedure is same as the basic procedure HEIGHT 167 7 cm WEIGHT 1 The LCD in ultrasonic height meter UHM 101 leads the user to measure height in correct posture It reduces the measuring error which can be occurred due to the incorrect posture such as head down 2 It starts measuring impedance when the user is in correct posture 3 During the measurement the user should straighten the back and fix the eyes on the monitor of height meter 90 3 Procedure using Blood Pressure Monitor When X SCAN PLUS 950 is connected to Blood Pressure Monitor both blood pressure and body composition can be measured Blood Pressure Monitor should be selected from one of the models from Jawon Medical Co LTD In this way the blood pressure can be monitored together with weight control It helps to
26. and reflected characteristics of ultrasonic height meter lt Good point of using UHM 101 as an option gt It automatically measures height 2 Fast measurement 3 Accurate measurement 4 LCD monitor attached to the column leads the user to measure height in correct way lt When using UHM 101 gt Install it in a place with stable temperature 2 Do not install it at the location facing the heater and air conditioner 3 Do not put a sticker or foreign things on body of the UHM 101 4 Nothing should be placed within a radius of 60cm Measuring height in the morning is even average 1 2cm higher than in the evening because vertebral cartilage is pressed maximum in the evening by owns weight x Model or specification of accessories can be changed according to market supply and demand A 3 Appearance of the device The front and back of X SCAN PLUS 950 looks as below It consists of D Display Operation Part 2 Body Part 3 Base Part Front Part Rear Part Display Operation Part Body Part 20 4 Term of each parts and its function 1 Display Operation Part Large LCD Color TFT It indicates the data the measurer input It also shows measuring process in messages and graphic display 2 Key pad There is a keypad in X SCAN PLUS 950 The function of each button is same as the touch screen 3 Touch panel LCD Liquid Crystal Display panel as touch screen
27. cement cartons to be shipped off from you to our company Shipping and insurance costs for return of defective unit must be prepaid by the users 10 5 SAFETY SYMBOLS AND INFORMATION The International Electro technical Commission IEC has established a set of symbols for medical electrical equipment which classify a connection or warning of any potential hazard The classifications and symbols are shown below Save these instructions for your safety Degree of protection against electric shock TYPE BF Please observe operating instructions General warning sign General prohibition sign o General mandatory action sign Caution Waste Electrical and Electronic Equipment WEEE The device could be sent back to the manufacturer for recycling or proper disposal after their useful lives Alternatively the device shall be EES disposed in accordance with national laws after their useful lives C ON OFF key Turn the power ON OFF Class Il equipment 11 7 This symbol is used inside system S Identifies the point where the safety ground of the system is fastened to the chassis Do not open This is for factory only Alternating current Direct current MN Date of manufacture Manufacturer A Non ionizing radiation EC REP Authorized representative in the European community For indoor use only RoHS2 12 6 Guidance for Electromagnetic compatibility EMC De
28. de is selected to measure body composition pull down the socks as show in the picture and make sure the user s ankle is touched on the electrode O correct stand X imbalanced touch x foreign matters O correct stand X Ankles are barely touched When using a ankle electrode be careful not to trip on the electrode before and after a measurement Use the ankle electrode after reading and understanding the instructions enough Especially the elderly and the infirm have to be more careful of the safety while using the ankle electrode 45 Grip handle electrodes with fingers and palms 4 electrodes should be touched impartially Stretch both arms and spread them 30 from the body O correct grip x grip with only palm x imbalanced touch If 8 electrodes are not perfectly touched during the measurement the result is not reliable or the device quits the measurement 1 When the subject has hands or feet that are too small to cover all electrodes sufficiently for measurement please pay attention to touch all electrodes fairly How one touches electrodes will affect the reliability of the analyzed value 2 During measurement the subject should not be touched by another person or by conductive materials 3 If 8 electrodes are not perfectly touched during measurement measuring is quit or the data is not reliable 44 2 Measurement Posture Step on the scale with bare feet Stretch both arms and s
29. e optimal range is 50 100 cm male 40 80 cm female 4 V F M Visceral Fat Mass V F M is indicated in kg unit Prediction of Abdominal Fat It is the graph of V F A If the user doesn t exercise and just keep the current life style the graph indicates how V F A increases and how BMR decreases every 5 years This graph gives motivation to manage daily life style Segmental Analysis Soft lean mass and edema index of five body parts left and right arms left and right legs and trunk are analyzed 1 Segmental S L M lt evaluates segmental S L M of 5 body parts arms legs and trunk in kg and percentage Dual bar graph of soft lean mass makes it possible to distinguish muscular looking body type from actual muscular body type 2 Segmental edema index Segmental edema index to 5 body parts is indicated with the ratio of extra cellular water and total body water and the ratio of extra cellular fluid and total body fluid Body Composition Change Check to change of body fat soft lean mass and weight for 8 times 08 Body Type Body type is determined by B M I and P B F Body type is classified into Low fat Low fat Muscular Over Weight Muscular Athletic Thin Standard Over Weight Borderline Low Muscular Over fat Thin Fat Obese Obese Obese Ill Assessment of E C W T B W Edema is the unbalanced state of intra and extra cellular water Edema can be increased by salty
30. ease insert USB MEMORY and measure again lf the message above appears even when USB memory stick is inserted take out the USB MEMORY and insert it again Please use the USB MEMORY which is provided by Jawon Medical Co LTD The data can be saved only when ID USAGE function is activated in SYSTEM SETUP 04 1 USB memory should be inserted only at the initial screen 2 When there s no data saved in FLASH MEMORY the message No saved data will appear Please insert USB memory after measuring body composition 3 When the saving format is changed from USB MEMORY to FLASH MEMORY the data saved in USB MEMORY should be transferred to PC 4 Please refer to program manual for more information 2 Data Deletion Press the upper left corner for 5 seconds on initial screen Password window will appear Press 1111 onthe password window The following message appears Do you want to delete all data lf you want to delete the data press YES to delete otherwise press NO When deleting the data the message All data were deleted will appear Press Close to return to initial screen Deleted data can not be restored 99 ang 1 Connect printer Beside the results displayed in LCD more information can be printed out in the A4 result sheet The printing procedure using A4 printer is as followings D Connect X SCAN PLUS 950 to A4 printer Connect X SCAN PLUS 970 to a computer in which the basic management prog
31. ect 2 CLOTHES on SYSTEM SETUP screen and press SET on touch pad Pre set 0 0 kg Range 0 0 9 9 kg Set the value by pressing V A on touch pad Every single press changes this value by 0 1 kg Press SET button on touch pad to save tt Return to SYSTEM SETUP screen by pressing CLOSE button on touch pad lt SCALE OFFSET gt lt compensates measured weight Calculated value SCALE OFFSET from this setting is used in body composition analysis Select El SCALE OFFSET on SYSTEM SETUP screen and press SET on touch pad Pre set 0 0 kg Range 9 9 9 9 kg Set the value by pressing V A on touch pad Every single press changes the value by 0 1 kg Press SET button on touch pad to save tt Return to SYSTEM SETUP screen by pressing CLOSE button on touch pad lt ABDOMINAL FATNESS gt It sets the analysis of abdominal fatness under 18yrs ABDOMINAL FATNESS Below yrs Select E abdominal fatness on SYSTEM YE SETUP and press SET on touch pad Pre set NO Choose YES or NO on touch pad If YES is selected abdominal analysis is displayed for all age If NO is selected abdominal analysis is not displayed for patients below 18 years old Press SET on touch pad to save it Return to SYSTEM SETUP screen by pressing CLOSE button on touch pad a0 lt DATE TYPE gt This is to set the format of the date DA
32. egmental Analysis This device analyzes soft lean mass body fat mass total body water and E C W T B W of five body parts trunk right arm left arm right leg and left leg This function can be used as an assessment tool to evaluate the result of exercise or rehabilitation treatment 7 Age Matched of Body It is the estimated physical age of the subject considering body composition analysis result gender and biological age This is calculated by comparing the optimal body composition based on the gender and biological age of the subject with the actual analyzed body composition lt can be used to evaluate the subjects health and body development 8 Study It is the provided impedance Impedance indicates the segmental impedance of five body parts left and right arms left and right legs and trunk corresponding to each frequency 1 1000 kHz 19 1 Main Parts The main system of X SCAN PLUS 950 consists of as follows Main body User manual Adapter USB Cable Data management program Bolts 5mm L wrench Body Cover Bluetooth D 2 4 6 O 9 1 Main body 2 User manual D 5mm L wrench Body Cover Data management Bluetooth program x Model or specification of accessories can be changed according to market supply and demand 20 2 Options 1 Ankle electrodes AE 202 Convenience can measure with one s socks or stockings on Ankle electrode Selectivity can choose either plate elect
33. eign substances 10 In case of inserting foreign substances or exposing to particular environment this device must be examined by an expert before use 11 Use the power cable plug and fuse that are offered by our company At this time confirm the covering of cable the state of plug connection and other check points e RS 232C cable USB port Adapter 12 When pulling out the power cable turn off the power switch first and then pull the plug out 13 Storage ambient Temperature 25 70 C Humidity lower than 93 non condensing 14 Operation ambient Temperature 5 40 C Humidity 15 93 non condensing 15 Do not store or use this device under 70 kPa 700 mbar or over 106 kPa 1060 mbar of atmospheric pressure 16 Cleaning amp Disinfection 1 Cleaning Use a soft gauze cloth with volatile liquid like alcohol Ethyl or Isopropyl alcohol 70 90 to clean it Clean it every 2 3days Do not use a wet cloth 2 Disinfection After measurement use a soft gauze cloth with volatile liquid like benzene and alcohol Then wipe the enclosure with soft lint Please wipe after every measurement for electrode disinfection 17 Refer to SAFETY PRECAUTIONS Users must wipe while wearing safety equipment such as gloves when disinfecting electrodes Our company does not take responsibility for safety accidents caused by user s carelessness ol 1 Kinds of error amp repair Out of range of impedance Out of
34. eration and long term performance stability it is essential that you fully understand the functions operating and maintenance instructions by reading this manual before operating your unit Particular attention must be paid to all warnings cautions and notes incorporated herein The following conventions are used throughout the manual to denote information of special emphasis Warning indicates important information about the presence of a hazard which may cause severe personal injury loss of substantial property damage if the warning is ignored Caution indicates important information about the presence of a hazard which may cause minor personal injury or property damage if the caution is ignored Notice indicates important information in order to notify installation operation or maintenance of this device Notice is important but not hazard related Hazard warnings are not included here 3 CLASSIFICATION AND COMPLIANCE 1 This device is classified as Class 1 type BF against electric shock Ordinary equipment without protection against ingress of water Equipment not suitable for use in presence of a flammable anesthetic mixture by standard of EN 60601 1 2006 Basic safety and essential performance of Medical Electrical Equipment 2 This device is complied with Class A for Noise Emission Level B for Noise immunity by standard of IEC 60601 1 2 2007 Electromagnetic Compatibility Requirements 4 SAFETY PRECAUTION
35. f body fat in abdomen increases more the risk to cardiovascular diseases diabetes etc becomes higher 5 Abdominal Fatness Body fat is divided into subcutaneous fat and visceral fat Visceral obesity is considered to be a Critical risk factor along with Percentage of body fat Lipoprotein lipase can be easily activated in visceral fat and it causes visceral fat to be dissolved easily Dissolved visceral fat goes into liver through the blood vessel and causes fatty liver or increases lipid in the blood It also elevates the risk of hyperinsulinemia 18 hypertension and cardiovascular disease Visceral fat generally occupies 10 20 of body fat and visceral obesity is assessed based on the indicators below the cross sectional fat area between L4 L5 is 100 cm and over the visceral fat to subcutaneous fat ratio is 0 4 and over the waist to hip ratio W H R is over 0 9 male 0 85 female the circumference of waist is over 102 cm 45 inches male 88 cm 35 inches female Visceral fat increases after 30s in men and after Menopause in women It is more common in men than women and the old than the young Visceral fat tends to increase with aging Because the combustion rate per minute of visceral fat is higher than that of subcutaneous fat visceral fat can be easily reduced by exercise or dietary control in case of abdominal obesity W H R is the ratio of waist to hip circumference and has relation to one s figure 6 S
36. food malnutrition postpartum exercise temporary fatigue etc It is divided into 3 steps Optimal Borderline Over B C M Body Cell Mass It consists of intra cellular water and protein Energy Expenditure 1 B M R Basal Metabolic Rate B M R refers to the calories required to maintain human body s basic function such as movement of heart brain neural transmission regulating body temperature and so on B M R is in proportion to S L M because body fat stores energy while muscle consumes energy Therefore even if the weight is same between persons the person with more muscle has greater B M R 2 T E E Total Energy Expenditure lt is the sum of basal metabolic rate and calories needed for daily activity Generally it is calculated by multiplying B M R by PAL Physical Activity Level A M B Age Matched of Body It is the estimated physical age of the subject considering body composition analysis result gender and biological age This is calculated by comparing the optimal body composition based on the gender and biological age of the subject with the actual analyzed body composition It can be used to evaluate the subjects health and body development Total score It is a physical total score which is evaluated considering a subject s body composition analysis result and biological age On the basis of 100 points the people in the balanced standard body type get scores around 80 The more the subject is healthy and has soft
37. for 5 minutes 6 Clean both the electrodes and measuring body parts Changes in room temperature may affect the results Measurement should be done in a temperature around 20 C Body composition and weight varies even during a day Therefore the measurement should be performed at the same time every day For a person who stands for a long period of time during the day it is advised to measure in the morning 9 Go to bathroom before measurement Maintain correct position and posture during the measurement 42 In order to keep one s health and the balance of body composition check the changes of body composition through continuous analysis and compare the results Make sure that the body composition should are measured under the same physical and environmental conditions If the condition before the measurement such as volume of a meal meal time and activities exercise Sauna drinking lots of beverage urination etc are kept same the reproducibility of a device is obtained Therefore the data can be used to evaluate the change of body composition 2 Correct position to measure 1 How to touch electrodes Make sure that the plate electrodes are clean Take off the socks or stockings then stand on the plate electrodes Remove sweat or foreign matters on the soles Fairly place the bare feet on the plate electrodes Make sure that the clothes are not between the soles and the plate electrodes When ankle electro
38. g and transporting please work in teams of minimum 2 people to ensure safe operation 10mm 6angles wrench 1 Components for installing an ankle electrode SL Top cover M4 bolt M12 bolt Flat ashe Ankle electrode 3mm 6angles wrench a A 2 Installing an ankle electrode Turn off the power of the device and disconnect the power cable before installing an ankle electrode POWER OFF m COMPUTER EXTERNAL USB GE Te ee O SY a ow Se E A Sy d HEIGHT LOOD PRESSURE ADAPTER 12V SA E SRD MR TF E HS HW Sy A 0 GN 6S aD GR A E AA rr rr rr rr rm a 06 Detach the top cover from the scale by using a driver 4 Connect the RS 232C port of the ankle electrode to the weight scale as shown in the picture Ankle electrode RS 232C port E 87 Grip the ankle electrode with one hand and fix it on the scale firmly by using M12 bolt 10mm 6 angle wrench and M4 bolt 3mm 6 angle wrench M4 bolt 6 After that try shaking the ankle electrode to check if the fixation is good or not X Bad O Good 88 D Remove the protective vinyl and double faced sticker inside of the top cover 09 Power on After finishing the installation connect the adapter and power cable and turn on the device lf you press the power saving button on the right side of the column as shown in the picture it turns to power saving mode Power
39. ied by IEC 950 or equivalent standards for data processing equipment Configurations shall comply with the system standard EN 60601 1 2006 Everybody who connects additional equipment to the signal input part or signal output part configures a medical system by standard EN 60601 1 2006 If in doubt consult the A S department of local distributor Avoid the following environments for storage Where the ambient temperature falls below 25 C or exceeds 70 C Where the atmospheric pressure falls below 70kPa 00mbar or exceeds 106kPa 1060mbar Where the humidity is over 93 non condensing Where the unit is exposed to spray or splashing water Where the unit is exposed to dust Where the unit is exposed to water vapor Where the unit is exposed to salty atmosphere Where the unit is exposed to explosive gas Where the unit is exposed to excessive shocks or vibrations Where the angle of inclination of mounting surface exceeds 10 degrees Where the unit is exposed to direct sunlight This device needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in the ACCOMPANYING DOCUMENTS Cross contamination is possible because this equipment is used with bare hands and feet Refer to the cleaning and disinfecting methods in this manual Measurements may be impaired if this device is used near televisions microwave ovens X ray equipment or other
40. inside of the unit so users cannot open it themselves The manufacturer and its agent will not bear any responsibility for problems or damages caused by the user opening it by force 26 1 Power Supply Connect the power cable to the ADAPTER INPUT placed on the lower back panel of the device Connect the cable Turn on the power switch placed next to Power input then after moment initial screen animation is displayed automatically 1 Before connecting a peripheral device to the device the power should be turned off Otherwise the devices can be damaged by electric shock or malfunction 2 When the device and the peripheral devices are connected each other the order of turning of the devices should start from the device to keep the functions and safe of the device 3 This device should be only powered through the cable provided by OUR COMPANY 4 Be careful not to touch the base part of the scale when switching on the device If at turning on the switch loads any weight on plate electrode a measuring error might occur with the scale s zero point When connecting the adaptor place the arrow mark of adaptor connection part up and correctly stick it in the socket on the rear of the main body Wrong connection could be a hazard al 2 Peripheral Device Installation 1 Connecting computer Connect the COMPUTER port placed on the rear panel of this device to the computer with USB cable Or it can be co
41. interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the X SCAN PLUS 950 as recommended below according to the maximum output power of the communications equipment Rated maximum Separation distance according to frequency of transmitter output power m of transmitter 150 kHz to 80 MHz 80 MHz to 900 MHz 900 MHz to 2 5 GHz d 1 2 P d 1 2 P d 1 2 P For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer 1 At 80 MHz and 900 MHz the separation distance for the higher frequency range applies 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people 17 1 Body Composition Human body consists of body fat and lean body Lean body means non fat constituents of human body like body water muscles mineral etc Body water is divided into intra and extra cellular water and the ratio between them is controlled and maintained within a certain range Body fat is piled beneath the skin and between abdominal organs Body fat is hydrolyzed to make energy needed to normal physiological function when energy supply
42. magnetic environment guidance Electrostatic 6kV Contact discharge ESD 8kV Air IEC 61000 4 2 2kV supply lines 1kV Input output Power Electrical fast transition burst IEC 61000 4 4 lines 1 differential Surge IEC 61000 4 5 mode 2 kV common mode lt 5 UT gt 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT of for 5 cycles 70 UT 30 dip in UT for 25 cycles lt 5 UT gt 95 dip in UT for 5 sec Voltage drops dips and fluctuations input power supply line IEC 61000 4 11 6kV Contact 8kV Air 2kV supply lines 1kV Input output Power lines 1 kV differential mode 2 kV common mode lt 5 UT gt 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles lt 5 UT gt 95 dip in UT for 5 sec Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Mains power quality should be that of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospital environment If the user of the X SCAN PLUS 950 requires continued operation during power mains interruptions it is recommended that the X SCAN PLUS 950 be powered from an uninte
43. manage the body fat while checking the blood pressure simultaneously The measuring procedure is as follows Connect a Blood Pressure Monitor to the device 2 Connect the device to a computer 3 Turn on the power of BPM and the computer Turn on the device 4 Input personal data to create a new ID or input an ID which is already registered 5 Measure blood pressure first 6 Measure body composition 7 The results of blood pressure and body composition are immediately displayed on the computer screen after the completion of body composition analysis Save the data or print it out ol 1 Storage of data 1 On selecting FLASH MEMORY 1 Insert USB memory stick into USB A jack placed on the back side of the device 2 The following message appears Do you want to write data to USB memory stick on initial screen Press YES to send data to USB memory 3 Transmitting message will be displayed on the screen When transmission is complete the message The data writing was completed will be shown Press CLOSE to complete the saving process AS ee EEN 2 On selecting USB MEMORY When USB MEMORY is selected measurement data will be stored to USB MEMORY without notification Data can only be saved when USB MEMORY is inserted only at the initial screen of device If USB MEMORY is not inserted during the measurement the message USB MEMORY is not connected appears Data will not be stored Pl
44. nce level in each frequency range Interference may occur in the vicinity of equipment marked with the following symbol o 1 At 80 MHz and 900 MHz the higher frequency range applies 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the X SCAN PLUS 950 is used exceeds the applicable RF compliance level above the X SCAN PLUS 950 should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating the X SCAN PLUS 950 P Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m 16 Recommended separation distances between portable and mobile RF communications equipment and the X SCAN PLUS 950 The X SCAN PLUS 950 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the X SCAN PLUS 950 can help prevent electromagnetic
45. nnected through Bluetooth 1 If use USB port the cable should be connected to the computer port 2 When use computer port USB driver should be installed at first For more information please refer to the manual CD of software 2 Connecting Printer Connect A4 Printer to the PRINTER port placed on the back with USB cable There are two ways to connect printer Unit Printer interface directly 2 Unit Computer Printer connecting 20 1 In order to save search and retrieve the users data the user should connect the analyzer to the computer installed data management software offered free Printing is done through computer in this case 2 The professional consulting software optionally provides various printouts In case of using the software the pre printed result sheet is not used 3 Refer to user s manual for installation of software supplied with CD 3 Connecting Blood Pressure Monitor Connect blood pressure monitor to BLOOD PRESSURE port placed on the rear panel of the main unit with RS 232 cable See following figure 29 4 Ultrasonic Height meter UHM 101 For assembly push the lower board of the ultrasonic height meter into the bottom back of X SCAN PLUS 950 Fix the left and right parts firmly using hinge and screw Connect RS 232 cable to the HEIGHT port placed on the rear panel of X SCAN PLUS 950 30 SS SYSTEM SETUP allows the users to change the setting of operati
46. ntile is presented on the ADULT result sheet in case of under 18 3 AUTO It automatically selects and prints a CHILD result sheet in case of under 18 and an ADULT result sheet in case of 18 or over 18 PLATE ANKLE lt PLATE ANKLE gt Select either plate electrode or ankle electrodes Pre set Plate electrode Enter into the menu view Choose PLATE or ANKLE on touch pad Press SET button to save it and return to main SYSTEM SET UP view with CLOSE button 38 lt SEGMENTAL RESULT SHEET gt Segmental result sheet option can be selected Pre set NO SEGMENTAL RESULT SHEET Select El to enter the menu Select YES or NO Press SET to save the setting and press CLOSE to return to main SYSTEM SETUP screen In case of choosing YES two result sheets for Body composition analysis and Segmental analysis are printed together and in case of choosing NO only the result sheet for Body composition analysis is printed lt HEIGHT METER gt Adjust the height meter and select the use of height meter Preset OFF HEIGHT METER Select n HEIGHT METER to enter menu screen Press ON or OFF on touch pad Press SET button for completing the setup Press CLOSE button to return to initial screen of SYSTEM SETUP 1 Height meter is an option 2 Activate the use of height meter in SYSTEM SETUP when you connect height
47. odes connects with ankle Connect to ankle all 4 electrodes once more insufficiently 02 Can t input the height Can t measure the weight When the subject s height is deviated from the limit Incorrect input of height When the subject s weight deviates from the limit Measuring error Moving during the measurement 63 e Input height correctly If the subjects height is out of range height can t be entered e Measure the weight again Dont move or speak during measurement e lt can t measure if the weight is out of range e When the same error occurs even after re measurement please contact our company or its local distributor from where device is purchased 2 Error occurrence amp Repair that the P B F is too low or In case too high Machine doesn t Work When start button is pressed e Measuring method Measuring is done under unstable hydration state such after as just physical exercise a bath sweating drinking or overeating e Move or speak during measurement e Electrode holders or measuring are dirty e Faulty in impedance parts measuring e When the electrode holders are disconnected from the main body or contact is faulty e Start defective button is e Measure again in stable physique e If there is movement or speaking during measurement the weight and impedance are not correct Measure again correctly e
48. onal parameters For the purpose of improvement the contents in SYSTEM SETUP can be changed 1 Entering SYSTEM SETUP On the initial display press Es button on LCD for 3 5 second to enter System Set up 2 Menu in SYSTEM SETUP Menu items are displayed The function of each icon is as follows 1 DATE TIME 2 VOLUME SYSTEM SETUP 3 PRINT 1213 4 PRINT POSITION 5 CLOTHES 6 SCALE OFFSET Te 7 ABDOMINAL FATNESS 8 DATE TYPE 1218 1415 9 COMMUNICATION 10 ID USAGE 11 CHILD ADULT AUTO 12 PLATE ANKLE 13 SEGMENTAL RESULT SHEET 14 HEIGHT METER 15 QR CODE DOMAIN 3 Entering MENU view SYSTEM SETUP Select menu according to one s desire and confirm changes using SET button 31 4 How to escape from SYSTEM SETUP SYSTEM SETUP Press CLOSE button on SYSTEM SETUP phase then back to initial view of the analyzer DATE TIME 5 How to move into SYSTEM SETUP Press CLOSE button on the menu view then program is returned to SYSTEM SETUP phase 32 6 Set Up lt DATE TIME gt lt sets date and time year month day hour and minute DATE TIME Select E DATE TIME on SYSTEM SETUP vzarn 2011 screen and press SET button on touch pad ga Pre set The date of the device released from the DAY manufacturer s factory 16 __ 19 Set YEAR by pressing V A on touch pad Press MONTH and set Month Choose DAY HOUR MIN and
49. pread them 30 from the body Press start buttons with thumbs for 2 3 seconds to start the measurement Once it starts release the start button and hold the same posture until the measurement Is over Do not speak or move the body until the measurement is completed Do not bend or shake the arms until the measurement is completed The measurement will be stopped if all eight electrodes are not fairly touched lt Correct posture gt lt Incorrect posture gt Do not bend the arm Do not move Don t move and the arms Open arms about 30 Keep touching Open about 30 degrees degrees all electrodes 45 3 Measurements Procedure When the power is turned on the measurement starts 1 Basic Procedure There are two ways to measure impedance Plate electrode or Ankle electrode Either one can be selected at the SYSTEM SETTING D Measure weight When the power is on the initial screen appears as shown in the picture The following message appears To start please measure your weight When the user steps on the scale the measurement starts with a chime bell If the user moves on the scale voice guidance warns as follows Don t move or speak please After the weight measurement the screen changes as shown in the picture 2 Input ID Input an ID ID can have up to 20 characters Press DONE to save after input 46 To start the measurement please step on the scale 3
50. r Drop Normal Abnormal Horizontal bolt Horizontal Meter 9 Check the condition after adjusting the level The condition of horizontality and assembly is good The condition of horizontality or assembly is bad Please assemble it again 90 Less than 90 82 Connect the RS 232C Cable to HEIGHT port on the backside of the device as shown in the picture and then connect the adapter After connecting cables turn on the main body and UHM COMPUTER BACK COVER meee 00D A a g D If a height is less than 120cm measure the height after putting a reflector down on the LCD of UHM as shown in the picture 83 3 Connecting Height meter Bluetooth D Unscrew the fixing bolts on the upper cover of the backside of the height meter and lift up the lower cover to the arrow direction using a driver and separate the cover Connect the Bluetooth which connected with a cable to the EXTERNAL port on the back side of the device and switch on the Bluetooth D Connect the adapter of the main body and turn it on Push and pull down the lower cover to the arrow direction and then fix the upper cover with bolts 04 3 Check the location of the bracket hole and stick to the Bluetooth and fix it on the backside of the height meter as shown in the picture Joint of bracket 85 4 Assembling an ankle electrode option When installing packin
51. r devices in the vicinity However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to other devices which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving device Increase the separation between the equipment Connect the equipment into an outlet on a circuit different from that to which the other device s are connected Consult the manufacturer or field service technician for help Place the Weighing Platform on a level and stable surface If the equipment is used when the Weighing Platform is unstable because not all feet are on the surface there may be a risk of stumbling or inaccurate measurement Note that portable and mobile RF communications equipment can affect MEDICAL ELECTRICAL EQUIPMENT Consult a physician or a trained health professional for interpretation of measurement results In case of patients who have certain diseases the estimates might be different Incorrect operation or failure of user to maintain the unit spares the manufacturer or his agent of the responsibility for system s non compliance with specifications or responsibility for any damage or injury This manual is made for informational purposes and this manual and product are not meant to be a substitute for the
52. ram is installed 2 Result sheet There are two kinds of result sheet One is for body composition analysis and the other is for segmental assessment For Body composition analysis Users can see the overall body composition analysis Body water Protein Mineral Body fat Soft lean mass and etc 2 For Segmental assessment option Users can see the segmental assessments of left arm right arm left leg right leg and trunk Segmental E C W T B W Segmental S L M Segmental M B F and etc Use it for checking the body balance o4 EN esuctntenpnerarion X SCAN PLUS 950 indicates the synthetic analysis including edema assessment prediction of abdominal fatness segmental analysis etc Explanation of each item is as follows 1 Personal Data The subject s ID name date height weight age and gender are indicated on the result sheet 2 Company Logo The user can input LOGO such as name of hospital sports center or obesity clinic telephone number address contact person etc Refer to the manual of software for logo insertion 3 Body Composition Analysis Total weight is a combination of bone ligament tendon organs fluids muscle and fat When a person loses weight by the optimal fitness programs or gains weight the components of the weight will probably change as well as the ratio of these components to one another Body composition table provides the analyzed result and optimal range based on the standard
53. rodes or ankle electrodes 2 Hygienic protects from mold or bacteria 3 High accuracy analyzes more accurately for the person whose sole is corneous 2 Professional health counseling support software This program helps managing body composition easily and Health counseling systematically It shows the core items needed to control body support software composition The items include measured body composition dietary control plan exercise plan etc If the device is connected to blood pressure monitor it also indicates the measurer s blood pressure 3 A4 result sheet for segmental parts and children A4 result sheet for segmental parts and It shows the segmental results and children growth curve to make children users easily understand the condition of 5 body parts and the growing state of children 4 Automatic Blood Pressure Monitor If Jawon s automatic blood pressure monitor for hospital is connected to this device the measurer can easily check his her blood pressure Especially the patient with hypertension may be able better manage his her blood pressure through weight control 5 USB memory lt is possible to check the result on PC through USB memory al 6 Ultrasonic Height Meter UHM 101 Ultrosonic Height Meter It is an instrument to measure users Height more accurately and quickly It employs standoff determination method using ultrasonic sensor It combines the technology of artificial intelligence
54. rruptible power supply or a battery Magnetic field Power frequency magnetic fields 14 of commercial should be at levels characteristic frequency of a typical location in a typical 50 60Hz commercial or hospital IEC 61000 4 8 environment UT is the a c mains voltage prior to application of the test level 3 Guidance and manufacturer s declaration electromagnetic immunity 2 The X SCAN PLUS 950 is intended for use in the electromagnetic environment specified below The customer or the user of the X SCAN PLUS 950 should assure that it is used in such an environment IEC 60601 test Compliance Electromagnetic environment Immunity test level guidance Portable an mobile communications equipment should be used no closer to any part of the X SCAN PLUS 950 including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Conducted RF 3 Vrms Recommended separation IEC 61000 4 6 150 KHz to 80 MHz distance d 1 2 P Radiated RF 3 V m IEC 61000 4 3 80 MHz to 2 5 GHz d 1 2 P 80 MHz to 900 MHz d 2 P 900 MHz to 2 5 GHz where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the complia
55. saving button I ee K Ao Power on m c S amp S COMPUTER EXTERNAL USB OD 4 HEIGHT PRESSURE ME L ss z ze e e an P e a a aoao or 90 Periodic Check List Management No Visual Check Visual Cheek o d o o Mainframe 1 Enclosure No scratch crack Pass Fail nana 2 Labels and panels No peeling and dust Pass Fal fsluoo Nodamage Passa 4 Electrodo Nosoratch and damage Passat 2 User manual Keptinproperplace Pass Fal Mechanical Check A 2 Recorder Smooth operation with no Pass Fail A ama ae 3 Touch Screen Smooth operation Pass Fal Accessories 1 Power cord Smooth operation and Pass Fail removal Electrical Check Performance 1 Power supply Screen display upon Pass Fail 2 Display No abnormality and Pass Fail epee lier printing possible Pass Fail Model X SCAN PLUS 950 Daily Check List Management No No scratch crack 1 Enclosure Pass Fail deformation and rust falco Nodamago Passa 4 Electrode No scratch and damage Passa 2 User manual Keptinproperpiace Passa Mechanical Check Mainframe Smooth operation with no 2 Recorder Pass Fail abnormal sound Smooth operation and Accessories 1 Power cord Pass Fail removal Electrical Check rr a Screen display upon 1 Power supply Pass Fail power on No abnormality and Performance 2 Display Pass Fail
56. ss Body type Body cell mass Basal metabolic rate Total energy expenditure Age matched of body Total score Study item Segmental impedance classified by frequency Blood pressure if it is interlocked with blood pressured monitoring system QR code Segmental Result Option Segmental total body water Segmental intra cellular water Segmental extra cellular water Segmental ratio of E C W T B W Segmental E C F T B F Segmental soft lean mass Segmental mass of body fat and percent Study item Segmental impedance classified by frequency Result sheet for children Option Weight Standard weight Lean body mass Mass of body fat Subcutaneous fat mass Skeletal muscle mass Soft lean mass Protein mass Mineral mass Total body water Intra cellular water Extra cellular water Body mass index Percent of body fat Waist to hip ratio Body type Fatness Child growth curve height weight Body cell mass Basal metabolic rate Total energy expenditure Age matched of body Nutritional assessment Body composition change Segmental soft lean mass Segmental mass of body fat Study item Segmental impedance classified by frequency QR code Power supply Input AC 100 240V 50 60Hz ora OOOO Transmission device USB port RS 232C Bluetooth Wi Fi Option Available of external port extension Option 496 x 820 x 1150mm W x D x H About 42kg main unit 66 Measuring weight 10 270 kg 22lb 594lb Applicable age
57. tails about the electromagnetic compatibility EMC of the X SCAN PLUS 950 are given below Before using the X SCAN PLUS 950 be sure to read and understand the following information 1 Guidance and manufacturer s declaration electromagnetic emissions The X SCAN PLUS 950 is intended for use in the electromagnetic environment specified below The customer or the user of the X SCAN PLUS 950 should assure that it is used in such an environment Emissions test _ Compliance Electromagnetic environment guidance The X SCAN PLUS 950 uses RF energy only for RF emissions a Its internal function Therefore its RF emissions rou CISPR 11 P are very low and are not likely to cause any interference in nearby electronic equipment RF emissions Class B CISPR 11 Harmonic The X SCAN PLUS 950 is suitable for use in all emissions Class A establishments including domestic IEC 61000 3 2 establishments and those directly connected to Voltage the public low voltage power supply network that fluctuations supplies buildings used for domestic purposes Compliance flicker emissions IEC 61000 3 3 13 2 Guidance and manufacturer s declaration electromagnetic immunity The X SCAN PLUS 950 is intended for use in the electromagnetic environment specified below The customer or the user of the X SCAN PLUS 950 should assure that it is used in such an environment IEC 60601 test Compliance Immunity test level level Electro
58. through food intake is not sufficient but excessive fat in the body itself is a kind of disease and causes lifestyle diseases Healthy people maintain the balance of body composition in a steady proportion but unhealthy people persons fail to keep this balance When the balance in body composition is broken diseases like obesity malnutrition osteoporosis etc can be caused 2 Obesity Various methods can be used to assess obesity but the key factor in obesity assessment is the amount of fat accumulated in the body In general obesity is defined as the state of not only excessive weight compared with height visible obese but also excessive body fat compared with weight invisible or visible obese Strictly soeaking obesity is the state that body fat occupies considerably high ratio to weight 3 Necessity of Body Composition Analysis Body Composition Analysis is a good indicator in finding possible health problems Body composition analysis enables professionals to find obesity or imbalance in body composition at an early stage and helps subjects keep their body healthy 4 Waist to hip ratio Waist to hip ratio W H R shows the distribution of fat stored in one s abdomen and hip It is simple but useful to assess body fat distribution Body fat is stored in two distinct ways They are often categorized into and called apple and pear type Apple type shows bigger girth of waist than hip and pear type has bigger girth of hip than waist I
59. tom board on the floor and fix the lower body as shown in the picture TS A person grasps the lower body not to be shaken and the other unscrews two fixing bolts from the back cover on the upper body using a driver and separate it 3 Aperson grasps the lower body not to be shaken and the other lifts up the back cover on the upper body and separate it z J a l y e a i 19 4 Fix the M6X12 wrench bolt to the groove on the bottom side of the lower body of the height using the 5mm 6angles wrench Lower body Adjust bolt While a person takes the top harness of UHM out to the inside of the lower board the other puts a upper body supporter into two halls on the top of lower body as shown in the picture aa AW h T 80 6 Connect one side of the connector ot the RS0232C cable which is separately packed apart from the harness of UHM to the port attached to the inside of the lower board of the height meter The connector on the other side of the RS 232C cable will be connected with the BCA AR za 0 a mm _ Iza ol Set the level of the horizontal meter by spinning 4pcs of horizontal adjusting bolts Two horizontal adjusting bolts are attached in the bottom of the lower board of UHM and the other two are attached in the reinforcing board of UHM Horizontal bolt Wate
60. ure using Blood Pressure Monitor AAA 51 STORAGE OF DATA USING USB MEMORY AAA 52 PRINTING AAA 54 RESULT INTERPRETATION AAA 55 STORAGE amp MAINTENANCE AAA 61 ERROR amp REPAIR AAA 62 1 Kinds of Error amp Repair AAA 62 2 Error Occurrence amp Repair AAA 64 AFTER SERVICE AAA 65 1 AFTTER SERVICE AAA 65 2 PACKING AND TRANSPORT AAA 65 SPECIFICATION AAA 66 WARRANTY AAA 68 INSTRUCTIONS FOR ASSEMBLY AAA 69 1 HOW TO INSTALLA DEVICE AAA 69 2 ASSEMBLING AN Bluetooth OPTION AAA 75 3 ASSEMBLING A HEIGHT METER OPTION AAA 78 4 ASSEMBLING AN ANKLE ELECTRODE OPTION sunuununsununnunsunuunuununuunuspunuununpununnunn 86 We highly appreciate that you chose our company s product You are kindly requested to be familiar with these directions before using this product and always keep it together with the product In case you are not sure about any directions or problems arising while using the product please contact our service center We will provide you with detailed instructions 1 INTENDED USE This device measures impedance by bioelectrical impedance analysis method and provides lots of information using measured impedance and inputted personal data height age gender weight lt shows body composition of MBF LBM SLM SMM TBW protein mass mineral mass etc and information regarding BMI PBF BMR abdominal analysis Target to control segmental analysis Body composition change etc 2 WORD DEFINITIONS To ensure safe op
61. which consists of soft lean mass and body water 7 T B W Total Body Water The weight of body water LC W Intra Cellular Water Water existing in inner cell 9 E C W Extra Cellular Water Water existing in outer cell membrane like plasma and ISF etc Other than measured data additional evaluation and optimal range based on standard weight are also indicated For example Weight Optimal lt evaluates measurer s condition based on the standard Weight Optimal 61 6 58 4 71 3 weight 61 6 It is the subjects actual weight 58 4 71 3 This is normal range according to subjects personal information 96 Body Status Body Status is displayed in a bar graph as shown in the picture It is very convenient in recognizing what to do Increase muscle Decrease fat Keep current Status etc Under Optimal Over Under Optimal Over Under Optimal Over Weight Weight Weight B M I B M I B M I P B F P B F P B F M B F M B F M B F S L M S L M S L M Type Overweight because of over fat Type Overweight because of much muscle mass Type Sarcopenic obesity Target Decreasing body fat Target Keeping current status Target Increasing muscle mass 1 Percent of Body Fat for Adults UI low fat normal overweight obese severe obese less than 15 15 lt 20 20 lt 25 25 lt 30 over 30 less than 20 20 lt 30 30 lt 35 35 lt 40 over 40 2 Body Mass Index kg m for Adults