Home
WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER
Contents
1. DMX Control Mode Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show In this mode you will be able to control each individual trait of the fixture and each fixture independently The RGB 252 uses 4 channels of control Enable the DMX control by setting dipswitch No 10 to the ON position Use dipswitches 1 9 to address each fixture accordingly Setting the DMX address The DMX mode enables the use of a universal DMX controller Each fixture requires a start address from 1 511 A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 105 and 106 Choose a start address so that the channels used do not overlap E g the next unit in the chain starts at 107 LED RGB 252 CONTROL OPTIONS Set the start address using the group of dip switches located usually on the back of the fixture Each dipswitch has an associated value Adding the value of each switch in the ON position will provide the start address Determining which switches to toggle ON given a specific start address can be accomplished in the following manner By subtracting the largest switch value possible from the selected start address until zero is achieved EXAMPLE STARTI
2. 3 pin XLR female socket sRrotopole aus dvscic isi aaa DMX 512 UTSITT e DMX channels cccceeeeeeenceeeeeneeueeeeaes 4
3. LED RGB 252 SAFETY WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION Keep this equipment away from rain moisture and liquids SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this equipment are not subject to warranty LED RGB 252 SAFETY IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment e Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution e Never remove warning or informative labels from the equipment e Do not open the equipment and do not modify the equipment e Do not connect this equipment to a dimmer pack e Do not
4. NG ADDRESS Address 10 Pin NO 4 8 Pin NO 2 2 Total 10 Address 24 Pin NO 5 16 Pin NO 4 8 Total 24 233 128 105 Turn on dip No 8 simple maths 41 32 9 Turn on dip No 6 9 8 1 Turn on dip No 4 1 1 0 Turn on dip No 1 3 4 4 8 You will most likely use the first available 5 16 number which maybe Number 1 This 6 32 b lected f d Se number was selected for 3 128 example purposes 9 256 10 LED RGB 252 DMX SET UP DMX 512 e DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX Linking e DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the midd
5. ammes SE E OY Daisy Chain Connection 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming from the first fixture which will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector Proceed to connect from the output as stated above to the input of the following fixture and so on INPUT FROM DMX CONTROLLER Continue OPTIONAL IN OUT I ONT OUT OUT x O O O O LINE LED RGB 252 CONTROL OPTIONS Manual Control Options Colour Selection e With Dip Switch 1 only set to ON you obtain static RED e With Dip Switch 2 only set to ON you obtain static GREEN e With Dip Switch 3 only set to ON you obtain static BLUE You can have any combination of switches 1 2 3 to obtain static colour mix Flashing Mode Once you have selected a static colour you can make it flash by using Dip Switches 4 5 6 4 is slow flash 4 amp 5 is medium flash and 4 5 amp 6 is fast flash For example if you wish to obtain a purple wash with a medium speed flash you would put dipswitches 1 and 3 red amp blue to ON to obtain purple and the Dip switches 4 amp 5 to ON to obtain a medium speed flash With all the Dip switches set to off this activates an internal slow colour mixing change and fade programme Blackout Mode With only dipswitch 10 set to ON the RGB 252 will blackout
6. le When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA Cable DMX cable requirements for DMX operation e The RGB 252 can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input output figure 1 Figure 1 Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight dealers Please quote CABL10 2M CABL11 5M CABL12 10M Also remember that DMX cable must be daisy chained and cannot be split LED RGB 252 DMX SET UP Notice e Be sure to follow figures 2 amp 3 when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 out io VW J Ge DMX 512 in 3 pin XLR Ge OL Sole S 3 pin XLR DMX GE XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground Pin 1 Ground 1 ground 2 cold Pin 2 Negative 3Hot 3Hot Pin 3 Postive FIGURE 3 FIGURE 2 Special Note Line termination e When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Termination reduces signal tra
7. nsmission problems and interferance it is always advisable to connect a Q DMX terminal resistance 120 Ohm 1 4 W between pin 2 DMX and pin 3 DMX of the last fixture Using a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors e Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The chart below details the correct cable conversion 3 Pin XLR to 5 PIN XLR Conversion Conductor 3 Pin XLR out 5 Pin XLR in Ground shield Pin 1 Pin 1 Negative Pin 2 Pin 2 Positive Pin 3 Pin 3 Dip Switch Reference Chart LED RGB 252 DMX Dip Switch Quick Reference Chart Dip Switch Position DMX DIP SWITCH wl 3 e e e LED RGB 252 DMX VALUES DMX Channel Values RED 000 gt 255 Green 000 gt 255 000 Shutter Strobe Dimmer Blackout 000 fone Intensity 001 lt gt 189 Strobe 190 lt gt 250 251 lt gt 255 Full on 251 lt gt 255 Technical Specifications Weight amp Dimensions Length eiie ana 455mm e e LE 155mm Ce LE 200mm Le LL 4 9kgs Power CAC IN EE 230V 50hz Fuse MAM EE 20mm Glass 0 5A Fast Blow Control amp Programming Data Input Ou eNEENSSERNERERSEN KANNER EEK eeEs Locking 3 pin XLR male socket AIR VE Locking
8. ntrolled individually allowing the creation of an unlimited range of colours The RGB 252 will operate in stand alone Master Slave sound activated and via DMX 512 control Note When linking the RGB 252 with LEDJ 56 and LEDJ 64 Par Cans the RGB 252 unit must be selected as the master unit LED RGB 252 MASTER SLAVE Master Slave The Master Slave mode will allow you to link up as many units as you want in a daisy chain fash ion In this mode the first unit in the daisy chain will control the following units 1 Connect all units in a daisy chain as described in the section following 2 For master unit in Auto mode Set dip switch 8 to ON and all others to OFF 3 For master unit in Sound Activation mode Set dip switch 8 9 to ON and all others to OFF 4 For Slave mode set dip swiches 10 1 to ON and all others to OFF DMX512 IN OUT DMX512 IN OUT Ueeeeeee na NWU P um Oh rd D w gt CH SE E MASTER SETTING SLAVE SETTING Stand Alone Mode e You can run the fixtures in an automatic stand alone mode by simply setting all fixtures to run as master units set dip switch 8 to on and all others off Sound Activation The RGB 252 has a built in microphone which enables it to operate in Sound to Light mode Set the sensitivity control to the desired level and the RGB 252 will change colour to the beat of the music Set dip switch 8 9 to ON to activate Sound Mode Dipswitches 1 8 progr
9. switch the equipment on and off in short intervals as this will reduce the system s life e Only use the equipment indoors e Do not expose to flammable sources liquids or gases e Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable e Make sure that the available voltage is between 220v 240v e Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically e If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again e If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature e If your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service e Only use fuses of same type and rating e Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS e WARRANTY One year from date of purchase OPERATING DETERMINATIONS If this equipment is operated in any other way
10. than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks lamp failure etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and property LED RGB 252 INTRODUCTION Introduction CONTROL FEATURES e 4 channel DMX RGB Flood e Blackout Dimmer Strobe e Individual control of Red Green and Blue LED s Features e 252 LED s Red 81 Green 81 and Blue 90 e Ultra bright 10mm LED s e Sound control via internal microphone e Colour change speed and strobe effect adjustable via dip switches e Multi colour changes e RGB Colour mixing e Master Slave functions e Sound activated e Rugged compact housing e Consumption 34w e Beam 40 degrees e Lamp life 100 000 hours OPTIONS DMX Channel Summary RED 0 100 Green 0 100 Shutter Strobe Dimmer Blackout 000 Intensity 001 lt gt 189 Strobe 190 lt gt 250 Full on 251 lt gt 255 Blue 3 0 100 LED RGB 252 OVERVIEW Product Overview 000000000000000 II Power Input Hanging Bracket DMX Out Dip Switches DMX In Setup Operating Instructions The RGB 252 is a DMX 512 controllable full RGB colour mixing flood made up of high efficiency and super bright LED s There are three colour groups red green and blue whose intensity can be co
Download Pdf Manuals
Related Search
Related Contents
MHS400. - Siegenia Installation Manual F5-23xx Series E1/T1 over IP Converter - ICT UA STAR Commercial Refrigeration Technician Exam Rexel 803921 folder Jabra Headset BT620s bluetooth stereo Gigabyte GA-EP43T-USB3 motherboard VECTOR - ITS - Chittagong Stock Exchange Belkin 10.2" Netbook Storage Sleeve NSC15ED - North Star Conditioning Copyright © All rights reserved.