Home

ph-pat02 - Zipato Flood Multisensor 3 in 1 User Manual v1.0

image

Contents

1. The device is based on Z Wave 500 series chip and has advantages as below e Concurrent multi channel support reduces external interference e Better RF range about 10 meters improvement indoors e Supports 100 Kbps transmission speeds speeds OVERVIEW lawwe PACKAGE CONTENT Flood Multisensor Trio Screws pack Sticker pack Quick Installation Guide FEATURES Flood temperature humidity sensors integrated in one device High sensitive linear flood detector New Z Wave 500 series chip brings better RF range indoors and up to 100 Kbps transmission speeds Higher output power to enhance the communication rangel 5dBm output power as compared to 2 5dBm 300 series Mounting can be done with tape or screws included in the box Tamper proof protection Over the air firmware update Extremely low power consumption 7 years battery lifespan Low power indication Easy installation Slim elegant design SPECIFICATIONS PROTOCOL Z Wave Plus POWER CR123A Lithium battery www zipato com BATTERY CAPACITY 1400mA OPERATING VOLTAGE 3 0V OPERATING CURRENT 35 mA STANDBY CURRENT 5 uA RANGE min 40m indoor 70m for indoor use only OPERATING TEMPERATURE 10 40 C TEMPERATURE DETECT RANGE 10 40 C TEMPERATURE DETECT ACCURACY 0 4 C HUMIDITY DETECT RANGE 80 RH WEIGHT DIMENSIONS MODEL AND FREQUENCIES EUROPEAN UNION EU version ph pat02 eu 868 42 MHz UNITED STATES US version ph pat02 us
2. everything under control FLOOD MULTISENSOR 3 IN 1 QUICK INSTALLATION GUIDE v1 0 TRADEMARKS Zipato and the Zipato logo are registered Trademarks All other product names mentioned herein may be trademarks or registered trademarks of their respective companies NOTICE Although Zipato has attempted to ensure the accuracy of the content of this manual it is possible that this document may contain technical inaccuracies typographical or other errors Zipato assumes no Liability for any error in this publication and for damages whether direct indirect incidental and consequential or otherwise that may result from such error including but not limited to loss of data or profits Zipato provides this publication as is without warranty of any kind either express or implied including but not limited to implied warranties of merchantability or fitness for a particular purpose The published information in the manual is subject to change without notice Zipato reserves the right to make changes in the product design layout and driver revisions without notification to its users This version of the Installation guide supersedes all previous versions ELECTROMAGNETIC COMPATIBILITY When operated according to manufacturer instructions the product complies with all applicable CE harmonised standards from EMC Directive 2004 108 EC and Part 15 of the FCC Rules The connections conducting HF signals must not be
3. 908 42MHz RUSSIA RU version ph pat02 ru 869 02MHz ISRAEL IS version ph pat02 is 916 02MHz AUSTRALIA AU version ph pat02 au 921 42MHz INDIA IN version ph pat02 in 865 20MHz INSTALLATION BATTERY INSTALLATION When the device reports low battery message the user should replace the battery with new one The battery type is CR123A 3 0V To open the front cover please press the top position and release the cover Replace the new battery and install the cover back 1 Press the front cover bottom and push down 2 Push the front cover top En V a ara ry bo x iter make your home smart MOUNTING To mount the device on the wall you can choose using the tape or the screw POWER UP PROCEDURE BATTERY POWER CHECK When the device powers up the device will detect the power level of the battery immediately If the power level is too low the LED will continue flashing for about 5 seconds If this is the case please replace the battery NETWORK WIDE INCLUSION NWI When the device powers on the device will check if it is already added to the network If it s not it will auto start the NWI mode The LED will flash every second for about 30 seconds until timeout or successful inclusion of device to Z Wave controller The user can press the tamper key 3 times to abort the NWI mode Not
4. configuration NO 23 the device will report humidity information to the nodes in the group 1 TIMING REPORT Besides the event triggered message reports the device also supports timing of unsolicited status reports Battery level report By default every 6 hours report is sent once It could be changed by setting the configuration NO 10 Low battery report When the battery level is too low every 30 minutes report is sent once Temperature report By default every 6 hours report is sent once It could be changed by setting the configuration NO 13 Humidity report By default every 6 hours report is sent once It could be changed by setting the configuration NO 14 Flood state report By default every 6 hours report is sent once It could be changed by setting the configuration NO 15 Notice The configuration NO 10 13 14 and 15 can be set to zero to disable the auto report And the configuration NO 20 can set the interval the default value is 30 if setting to 1 that means the minimum auto report interval will be one minute And please note that if you set this value to zero you will disable all of the timing reports except the low battery detection www zipato com Z WAVE CONFIGURATION SETTINGS For all of the configuration parameters the data size is 1 The configuration marked with star means that after removal of device from the network the setting will stay without reverting back to factory settings unless
5. damaged or altered in any way by the user TAKE CARE OF YOUR SAFETY Display extreme caution when using ladders or steps please follow manufacturer s instructions Be careful when using hand and power tools and follow the manufacturer s guidelines when using them Take care that the correct tools are used Wear goggles or protective clothing where required INTRODUCTION Zipato Flood Multisensor 3 in 1 integrates flood temperature and humidity sensors in one device connected to your Z Wave network of choice This device offers elaborate safety and ambient sensing options Multifunctional nature of this product allows you to be informed about water leakages and potential flood disasters as well as to measure temperature and humidity levels Flood Multisensor 3 in 1 is Z Wave Plus tm product it supports security OTA and all other new features of 500 Series Z Wave chipset Z Wave is a wireless communication protocol designed for remote control of appliances in residential automated homes and light commercial enviroments It can be used with lightning systems home access control entertainment systems and house appliances make your home smart This product can be included and operated in any Z Wave network with other Z Wave certified devices from other manufacturers and or other applications All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network
6. the network and wake up 10 seconds for to the setting commands The wake up interval setting is 30 minutes at minimum and 120 hours at maximum Press the tamper key once and device will wake up for 10 seconds Z WAVE MESSAGE REPORT When triggered by flood the device will report the trigger event and also report the battery status temperature and humidity levles By default the device will use Notification Report to represent the trigger event It can be changed to Sensor Binary Report by setting the configuration NO 7 Bit4 to 1 FLOOD REPORT When triggered by the flood the device will send the report to the nodes in the group 1 Notification Report V4 Notification Type Water Alarm 0x05 Event Water Leak detected Unknown Location 0x02 Sensor Binary Report V2 Sensor Type Water 0x06 Sensor Value OxFF After the flood trigger clears the device will send the report to the nodes in the group 1 Notification Report V4 Notification Type Water Alarm 0x05 Event 0x00 make your home smart Sensor Binary Report V2 Sensor Type Water 0x06 Sensor Value 0x00 TAMPER REPORT If tamper key is pressed for over 5 seconds the device will enter the alarm state In that state if the tamper key is released the device will send the report to the nodes in the group 1 Notification Report V4 Notification Type Home Security 0x07 Event Tampering Product covering removed 0x03 Sensor Bina
7. PATO PRODUCT FROM IN NO EVENT WILL ZIPATO BE LIABLE FOR LOSS OF DATA OR FOR INDIRECT SPECIAL INCIDENTAL CONSEQUENTIAL INCLUDING LOST PROFIT OR DATA OR OTHER DAMAGE WHETHER BASED IN CONTRACT TORT OR OTHERWISE HOWEVER NOTHING IN THIS AGREEMENT LIMITS ZIPATO S LIABILITY TO YOU I IN THE EVENT OF DEATH OR PERSONAL INJURY TO THE EXTENT RESULTING FROM ZIPATO S NEGLIGENCE OR II TO THE EXTENT RESULTING FROM ANY FRAUDULENT MISREPRESENTATION ON THE PART OF ZIPATO OR III TO THE EXTENT ARISING UNDER PART 1 OF THE CONSUMER PROTECTION ACT 1987 OF THE UNITED KINGDOM SOME STATES OR COUNTRIES DO NOT ALLOW 1 A DISCLAIMER OF IMPLIED WARRANTIES 2 A LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR 3 LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR CONSUMER PRODUCTS IN SUCH STATES OR COUNTRIES SOME EXCLUSIONS OR LIMITATIONS OF THIS LIMITED WARRANTY MAY NOT APPLY TO YOU THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS THAT MAY VARY FROM STATE TO STATE OR FROM COUNTRY TO COUNTRY YOU ARE ADVISED TO CONSULT APPLICABLE STATE OR COUNTRY LAWS FOR A FULL DETERMINATION OF YOUR RIGHTS This Limited Product Warranty applies to ZIPATO branded hardware products collectively referred to as ZIPATO Hardware Products make your home smart sold by ZIPATO Europe its European subsidiaries affiliates authorized resellers or country distributors collectively referred to a
8. SS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 TROUBLESHOOTING Having trouble installing your new product Zipato s website contains the latest user documentation and software updates for Zipato products and services www zipato com You can also find answers in the Zipato Community at community zipato com Zipato Support supportfazipato com LIMITED PRODUCT WARRANTY GENERAL TERMS Nothing in this Limited Product Warranty affects your statutory rights as a consumer The Limited Product Warranty set forth below is given by Tri plus grupa d o o Europe herein referred to as ZIPATO This Limited Product Warranty is only effective upon presentation of the proof of purchase Upon further request by ZIPATO this warranty card has to be presented too EXCEPT AS EXPRESSLY SET FORTH IN THIS LIMITED WARRANTY ZIPATO MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ZIPATO EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED IN DURATION TO THE LIMITED WARRANTY PERIOD TO THE EXTENT ALLOWED BY LOCAL LAW THE REMEDIES IN THIS WARRANTY STATEMENT ARE CUSTOMER S SOLE AND EXCLUSIVE REMEDIES AGAINST ZIPATO THEY DO NOT HOWEVER AFFECT OR RESTRICT THE RIGHTS YOU HAVE AGAINST THE BUSINESS YOU BOUGHT A ZI
9. at all deficiencies errors defects or non conformities will be corrected This warranty shall not apply to problems resulting from a unauthorized alterations or attachments b negligence abuse or misuse including failure to operate the product in accordance with specifications or interface requirements c improper handling d failure of goods or services not obtained from ZIPATO or not subject to a then effective ZIPATO warranty or maintenance agreement e improper use or storage or f fire water acts of God or other catastrophic events This warranty shall also not apply to any particular product if any ZIPATO serial number has been removed or defaced in any way ZIPATO IS NOT RESPONSIBLE FOR DAMAGE THAT OCCURS AS A RESULT OF YOUR FAILURE TO FOLLOW THE INSTRUCTIONS FOR THE ZIPATO HARDWARE PRODUCT LIMITED PRODUCT WARRANTY PERIOD The Limited Product Warranty Period starts on the date of purchase from ZIPATO Your dated sales or delivery receipt showing the date of purchase of the product is your proof of the purchase date You may be required to provide proof of purchase as a condition of receiving warranty service You are entitled to warranty service according to the terms and conditions of this document if a repair to your ZIPATO branded hardware is required within the Limited Product Warranty Period Other than in respect of products for domestic use in particular those listed in the first and last boxes in the tab
10. b CROATIA TEL 385 0 1 4004 404 FAX 385 0 1 4004 405 DECLARATION OF CONFORMITY d The manufacturer Tri plus grupa d o o declares under our sole responsibility that the product Marketing model Flood Multisensor 3 in 1 Regulatory model ph pat02 Trade Brand name Zipato is in conformity with the Low Voltage Directive 2006 95 EC EMC Directive 2004 108 EC R amp TTE Directive 1995 5 EC and carries the CE marking accordingly The following harmonized standards were applied R amp TTE 1995 5 EC EN 300 220 1 V2 4 1 EN 300 220 2 V2 4 1 EMC 2004 108 EC EN 301 489 1 V1 9 2 EN 301 489 3 V1 6 1 EN 6100 3 3 2006 A2 2009 EN 6100 3 3 2013 LVD 2006 95 EC EN 60950 1 2006 A11 2009 A1 2010 A12 2011 Changes or modifications not expressly approved by Tri plus grupa d o o for compliance could void the user s authority to operate the equipment re THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE Changes or modifications not expressly approved by Zipato for compliance could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are desig
11. e If the device is already added to the network the device will broadcast a node information once WAKE When the device powers on the device will be in wake state for about 20 seconds During this time the controller can communicate with the device Normally the device is always sleeping to save the battery energy ADDING TO Z WAVE NETWORK There is one tamper key on the back side of the device It can add remove reset or associate with from the Z Wave network For the first time you must join the device to Z Wave network First make sure the primary controller is in the add mode And then power on the device after taking out the insulation Mylar in the back side of the device The device will auto start the NWI Network Wide Inclusion mode and it should be included in 5 seconds You will see the LED lights up for one second Notice Including a node ID allocated by Z Wave Controller means Add or Inclusion Excluding a node ID allocated by Z Wave Controller means Remove or Exclusion INCLUSION Put Z Wave Controller in Inclusion mode Press the tamper key three times within 1 5 seconds to enter the Inclusion mode After successful join the device will enter wake state for 20 seconds in order to receive the setting command from Z Wave Controller www zipato com 01 EXCLUSION Put Z Wave Controller in Exclusion mode Press the tamper key three times within 1 5 seconds to enter the Exclusi
12. es designated by your local authorities some will accept your product for free or simply drop it off at your Zipato re seller store By recycling the product and its packaging in this manner you help to conserve the environment and protect human health At Zipato we understand and are committed to reducing any impact our operations and products may have on the environment To minimize this impact Zipato designs and builds its products to be as environmentally friendly as possible by using recyclable low toxic materials in both products and packaging COPYRIGHT 2015 Tri plus grupa d o o All Rights Reserved No part of this manual may be reproduced or transmitted in any form without the expressed written permission of Tri plus grupa d o o www zipato com 03
13. figuration No 20 The interval time for auto report the temperature Auto 0 means turn off auto Report X report 1g Tempera le 0 127 The default value is 12 ture Time The tick time can be set by the configuration No 20 The interval time for auto report the humidity Auto 0 means turn off auto Report report 14 Humidity 2 ORe default value is 12 Time The tick time can be set by the configuration No 20 make your home smart The interval time for auto report the flood state Auto 0 means turn off auto Report report 1 Flood 12 0 127 The default value is 12 Time The tick time can be set by the configuration No 20 The interval time for auto report each tick Setting this configuration will effect configuration Auto No 10 No 13 20 Report 30 0 No 14 and No 15 Tick OxFF Units of one minute Interval Caution1 Setting to 0 means turn off all auto report function Caution2 The value is unsigned byte The temperature differential to report 0 means turn off this function The unit is Temperature 0 Fahrenheit Enable this 21 Differential 1 0x7F function the device will Report detect every 10 seconds And when the temperature is over 140 degree Fahrenheit it will continue report The humidity differential to report Humidity eae turn off this 22 pees 5 0 60 The unit is percentage p Enable this function the device will detect every 10 seconds SECURITY NETWORK This device suppo
14. le below this Limited Product Warranty extends only to the original end user purchaser of this ZIPATO Hardware Product and is not transferable to anyone who obtains ownership of the ZIPATO Hardware Product from the original end user purchaser PRODUCT WARRANTY PERIOD TABLE PRODUCT TYPE Flood Multisensor 3 in 1 PRODUCT WARRANTY PERIOD One 1 year IMPORTANT The content of Product Type listed above is subject to change please refer to the www zipato com for latest update www zipato com PERFORMANCE OF THE LIMITED PRODUCT WARRANTY If a product defect occurs ZIPATO s sole obligation shall be to repair or replace any defective Zipato Hardware Product free of charge provided it is returned to an Authorized ZIPATO Service Centre during the Limited Warranty Period Such repair or replacement will be rendered by ZIPATO at an Authorized ZIPATO Service Centre All component parts or hardware products that are replaced under this Limited Product Warranty become the property of ZIPATO The replacement part or product takes on the remaining Limited Warranty Period of the replaced part or product The replacement product need not be new or of an identical make model or part ZIPATO may in its discretion replace the defective product or any part thereof with any reconditioned equivalent or superior product in all material respects to the defective product WARRANTOR Tri plus grupa d o o Banjavciceva 11 10 000 Zagre
15. ned to provide reasonable protection make your home smart against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help DISPOSING AND RECYCLING YOUR PRODUCT When it reaches end of life dispose of the product according to your local enviromental laws guidelines and regulations BATTERY DISPOSAL Dispose of batteries according to your local enviromental laws guidelines and regulations A This symbol on the product or packaging means that according to local laws and regulations needs to be disposed of separately from household waste Once this product has reached the end of its life please take it to a collection point recycle facilit
16. on mode Node ID has been excluded RESET Notice Use this procedure only in the event that the primary controller is lost or otherwise inoperable Press the tamper key four times within 1 5 seconds and hold it until LED lights up After 3 seconds the LED will turn OFF and after that you should release the tamper key within 2 seconds If successful the LED will light up for one second Otherwise the LED will flash once IDs are excluded and all settings will reset to factory default ASSOCIATION Put Z Wave Controller in association mode Press tamper key three times within 1 5 seconds to enter the association mode Note The device supports 2 groups The group 1 is for receiving the report message like triggered event temperature humidity etc The group 2 is for the light control the device will send the Basic Set command to this group And each group support 8 nodes at maximum e Failed or successful attempts of adding removing the node ID can be viewed from Z Wave Controller Notice Always RESET a Z Wave device before trying to add it to the Z Wave network Notice When the device enters NWI mode the sensor functionality will be disabled The NWI mode will timeout after 30 seconds You can press the tamper key 3 times to abort the NWI mode Z WAVE NOTIFICATION After the device joins the network it will wake up once per day by default When it wakes up it will broadcast the Wake Up Notification message to
17. rts the security function When the device is paired with security controller the device will auto switch to the security mode In security mode the following commands need to be wrapped using Security Command Classes to communicate otherwise there will be no response COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION_V4 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_SENSOR_MULTILEVEL_V5 COMMAND_CLASS_WAKE_UP_V2 OVER THE AIR FIRMWARE UPDATE The device supports Z Wave firmware update via OTA Put the controller into firmware update mode and then press the tamper key once to start the update After completing firmware download the LED will flash every 0 5 second At that time please don t remove the battery otherwise the firmware will fail and the device will stop functioning After the LED stops flashing it s recommended that user powers up the device Caution After removal of the battery please wait for about 30 seconds and then reinstall the battery Z WAVE COMMAND CLASSES COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION_V4 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 www zipato com 02 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_SENSOR_MULTILEVEL_V5 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLA
18. ry Report V2 Sensor Type Tamper 0x08 Sensor Value OxFF TEMPERATURE REPORT When triggered by flood or the temperature changes for over 1 Fahrenheit by default the device will send the Sensor Multilevel Report to the nodes in the group 1 Sensor Type Temperature 0x01 Note To disable sending temperature report after the flood trigger please set the configuration NO 5 bit5 to 1 Temperature differential report This function is enabled by default to disable this function set the configuration NO 21 to 0 By default when temperature changes plus minus one degree Fahrenheit 0 56 degree Celsius the device will report temperature information to the nodes in the group 1 The device will measure the temperature per every 10 seconds If the temperature is over 140 degree Fahrenheit 60 degree Celsius the device will report each measurement HUMIDITY REPORT When triggered by flood or humidity changes over 5 percent by default the device will send the Sensor Multilevel Report to the nodes in the group 1 Sensor Type Humidity 0x05 Note To disable sending humidity report after the flood triggering set the configuration N0O 6 bit to 1 Humidity differential report This function is enabled by default to disable it set the configuration NO 23 to zero If you enable this functionality the device will measure the humidity every 10 seconds And if the humidity is changed to plus or minus the value set in the
19. s ZIPATO Resellers with this Limited Product Warranty The term ZIPATO Hardware Product is limited to the hardware components and all its internal components including firmware The term ZIPATO Hardware Product DOES NOT include any software applications or programs GEOGRAPHICAL SCOPE OF THE LIMITED PRODUCT WARRANTY This Limited Product Warranty is applicable to Hardware Products sold by Zipato Resellers in all countries listed at the beginning of this document under the heading Countries in which this ZIPATO Limited Product Warranty applies The Limited Product Warranty will be honored in any country where ZIPATO or its authorized service providers offer warranty service subject to the terms and conditions set forth in this Limited Product Warranty However warranty service availability and response times may vary from country to country and may also be subject to registration requirements LIMITATION OF PRODUCT WARRANTY ZIPATO warrants that the products described below under normal use are free from material defects in materials and workmanship during the Limited Product Warranty Period set forth below Limited Product Warranty Period if the product is used and serviced in accordance with the user manual and other documentation provided to the purchaser at the time of purchase or as amended from time to time ZIPATO does not warrant that the products will operate uninterrupted or error free or th
20. user executes the RESET procedure The reserve bit or not supported bit is allowed any value without effects NO Name Default Valid Description Setting the BASIC command value Basic Set When the flood trigger Bl ree Center G 0x00 send the BASIC CC to the group 2 Setting the BASIC command value Basic Set When the flood trigger ONievel OF Center on 0xFF send the BASIC CC to the group 2 Operation mode Using bit to control Bit0 Disable the Flood function Bit3 Setting the 5 Operation 0 All temperature scale Mode 0 Fahrenheit 1 Celsius Bit5 Disable the temperature report after event triggered 1 Disable 0 Enable Multisensor function switch Using bit to control Bit6 Disable the humidity report after event triggered 1 Disable 0 Enable Multi Sensor Function 0 All Switch Customer function switch using bit control Bit3 Disable send out BASIC OFF after the flood event cleared 1 Disable 0 Enable Bit4 Notification Type 0 Using Notification 7 Costumer 0 All Report E Function 1 Using Sensor Binary Report Bit5 Disable Multi CC in auto report 1 Disable 0 Enable Bit Disable to report battery state when the device triggered 1 Disable 0 Enable The interval time for auto report the Auto battery level 10 Report 12 0 0 means turn off auto Battery 127 report The default Time value is 12 The tick time can be set by the con

Download Pdf Manuals

image

Related Search

Related Contents

Thermomètres et contrôleurs de température  Montageanleitung    Attack Gasification Boiler User Manual    

Copyright © All rights reserved.
Failed to retrieve file