Home
User Manual - Degree Controls Inc.
Contents
1. C Breeze Condensed Moisture Airflow Visualization System Thank you for choosing Degree Controls Inc C Breeze Fog System C Breeze is ideal for tracing air movements and is a sturdy and portable state of the art fog machine To ensure optimal performance of your unit please follow the suggestions in this user manual Important Notes amp Warnings Keep this device dry Always remove the battery or unplug the power adaptor to your C Breeze Fog System before filling the liquid tank Keep the unit upright Remove the battery or unplug the power adaptor when not in use This machine is not water or splash proof If moisture water or fog liquid gets inside the housing immediately remove power and contact Degree Controls Inc Never leave the unit running unattended Keep nozzle at least 20 50 cm away from contact with anything while in operation The fog vapour at point of release is under pressure and is hot Never aim the output nozzle directly at people Use in a well ventilated area Never cover the vents on the front of the C Breeze Never aim the output nozzle at open flames The output nozzle becomes hot during operation Keep flammable materials at least 20 50 cm away from the nozzle Always allow your C Breeze to cool down before attempting to clean or service it Do not expose the battery to excessive heat keep away from open flames Only use the supplied C Breeze Fog F
2. air velocity A amp temperature navigate the vast array of regulatory groups een e Excellent accuracy amp repeatability e Gain insights developed by our in house CFD analysis e Dedicated configerable alarm on team when designing your next cabinet or ductwork system velocity or temperature 2013 Degree Controls Inc all rights reserved 51300DS000 A00 Engineered Airflow Intelligent Cooling www degreec com e sales degreec com 18 Meadowbrook Drive Milford NH 03055 e TEL 603 672 8900 or 1 877 DEGREEC e FAX 603 672 9565
3. l costs for your client s facility e Develop client loyalty by providing cost effective easy to multiple locations simultaneously USB connection to PC install maintenance free Alarm Monitors e Highest reliability for safety you can depend on Biosafety Cabinet Fume Hood Critical Containment Manufacturers e 16 years of experience in airflow and fan blower control technologies e DegreeC s Cambridge Accusense an industry leading F400 HVAC Sensors technology in airflow temperature and humidity sensors Test and validation data collection with graphical display for system design engineers and regulatory compliance er oe a a O Thermal airflow sensor Sensitive to changes in air density Indicates very close to actual air ve locity and minimum compensation Facility Managers EH amp S amp Safety Compliance e Purpose built monitor and alarm systems to meet OSHA NSF and USP regulations e Easy to install calibrate and monitor air movement and room pressure in your facility e Provide on the spot confidence and safety for a fraction of complex ineffective facility wide systems Design Engineers amp Product Manager e We create the architecture from sensor design to complete blower and control systems e Access our 16 years in building systems management PCB Mounted HVAC and medical product industry Reference Sensors e Utilize our on site compliance director to help you e Provides fully linearized
4. luid Always make sure there is sufficient liquid in the liquid tank The fluid level can be monitored via the window at the back of the machine Operating this unit without Fog Fluid will cause damage to the pump and the heater If your C Breeze fails to work properly discontinue use immediately Drain all Fog Fluid from the tank remove battery pack the unit securely preferably in the original packing material and return it to Degree Controls Inc for service Always drain Fog Fluid from tank before shipping or transporting this unit Never drink Fog Fluid If it is ingested call a doctor immediately If Fog Fluid comes in contact with skin or eyes rinse thoroughly with water 2013 Degree Controls Inc C Breeze User Manual C Breeze Leftside View Power Button x Tube Breather Holes Extension Tube Remote Control Connection Battery Electrical Contacts on right side C Breeze User Manual Fluid Tank Level Battery Clip Battery Compartment Battery C Breeze Rightside View Extension Tube Insertion Extension Tube Momentary amp Toggle Switch Tube Breather Holes Tank Fluid Cap Fluid Tank Level Battery Clip 18 Meadowbrook Dr Milford NH 03055 4612 USA Phone 603 672 8900 Fax 603 672 9565 Web www degreec com Project Number NPI Group MS190 Part Number NPI Group MS190 Part Revision R01 Drawing Sheets 1of1 degree Title Battery Compartment C Breeze Co
5. ndensed Moisture Airflow Visualization Scale DO NOT SCALE DRAWING 1 000 2013 Degree Controls Inc Unpacking amp Inspection Open the shipping carton open the flight case and Note Battery requires 8 hours charging check to see if all equipment is inside and intact If time on the first charge any of the equipment is damaged or not working properly contact Degree Controls Inc immediately You should have received the following items C Breeze fogger Setup e Application tape e Remove all packing materials Check that all 12V rechargeable battery foam and plastic padding is removed especially e Battery charger and international plugs in the nozzle area 500 ml bottle of C Breeze Fog Fluid e Fill the unit with C Breeze Fog Fluid When Se peee usman filled place cap back on liquid tank and tighten e C Breeze Material Saftey Data Sheet MSDS e Charge the battery Plug the adaptor into a Carrying case grounded electrical outlet The green light on the battery charge will light up when it is connected to the power supply Then connect the charging head to the battery The battery will be fully charged in approximately 2 3 hours thereafter e The charge will last between 10 12 minutes of constant fog output before needing to be recharged e Align the C Breeze charged battery with the electrical contact of the battery on the right hand side of the center line e Lift the silver Batte
6. ning Clip in the back of the C Breeze and then pull the battery out e The machine will fog until the battery charge runs down or the C Breeze runs out of fog fluid When the C Breeze is connected to the optional power adaptor carefully monitor the level of the fog liquid to make sure the machine does not run out of liquid A full fluid reservoir is equivalent to approximately 50 minutes of fog A full battery will power the C Breeze for a period of 10 12 minutes before needing to be recharged Fog Dispersion e The machine can be operated at an angle that ensures the fog fluid in the bottle is drawn into the machine In practice this means that provided the reservoir is full on the sightglass the unit can be used to generate fog 45 from the horizontal plane Before using the machine make sure that the filler cap is tightened Toggle Action Push Button Important e Always monitor tank fluid levels as you are producing fog Running the C Breeze without fluid can perma nently damage the unit e If you experience low output pump noise or no output at all remove the battery immediately Check fluid level and recharge the battery When the liquid tank is full and the battery is charged plug the battery in and press the button on the handle e Ifthe machine is still not working and you are unable to determine the cause of the problem do not open the case There are no user serviceable parts inside Retu
7. rn the machine to Degree Controls Inc for service Extension Tube If fitting the extension tube for precise fog placement ensure that the tube s breather holes are at the end closest to the machine They are designed to draw air into the vapor stream and help the formation of fog e A small amount of deposition will occur over time in the extension tube due to the restric tion of the fog particles Always clean the extension tube after use C Breeze User Manual 2013 Degree Controls Inc 4 Optional Full Time Power When desired the C Breeze can be powered by an optional power adaptor which plugs into a standard electrical outlet The adaptor connects to a dummy battery which plugs into the battery slot on the C Breeze This allows for extended operation of the C Breeze Optional Remote Control Operation An optional Wireless Remote Control is avail able from Degree Controls Inc If using the Radio Remote always ensure the battery is fully charged or use a direct power adaptor with dummy battery Always ensure the C Breeze has sufficient fog fluid Using a miniature screw driver adjust the Slide Switch towards the reservoir as indicated by the yellow arrow this is the Momentary fog mode e Preparation Connect receiver to C Breeze as shown e To Make Fog Press the A button on the remote e To Stop Fog Press the B button on the remote Fog will stop within 10 seconds Remove
8. ry Retaining Clip on the rear face of the C Breeze e Slide the battery into the C Breeze pushing it all the way in Battery Insertion amp Clip gt 2013 Degree Controls Inc C Breeze User Manual Operation The C Breeze operates with or without the exten sion tube The unit can be operated instantly as no warm up time is required and has two modes of operation Momentary or Toggle To select the Momentary mode slide switch on the right hand side of the machine to the left towards the reservoir fogs only when the button is held down Select the Toggle mode by sliding the switch to the right towards the fog outlet pressing the fog but ton once starts fog pressing again stops fog e Start fog by pressing the button on the handle The LED will flash green and after 1 or 2 sec onds fog will be produced The C Breeze will fog continuously until the button is pressed a second time if Toggle or until the button is released if Momentary The Green LED will continue to flash for ap proximately 10 seconds after switch off Battery e When the LED turns Red the battery needs to be charged The machine will still be able to produce fog for a short period of time after the red light begins flashing e VERY IMPORTANT to give you optimum battery life remove the battery from the C Breeze when you are done using the machine To remove the battery lift the silver Battery Retai
9. s 227 mm x 66 mm x 81 mm 8 9 in x 2 6 in x 3 1 in Input 100 240V 2A 50 60 Hz DC Output 12V 5 8A Max 70 W Fog Fluid Propylene Glycol Fog Condensed Moisture Vapor Bottle Volume 500 ml 25 hours of continuous operation This Product Uses Propylene Glycol Use only Degree Controls Inc C Breeze Fog Fluid in this device Propylene Glycol is the main ingredient and can be pur chased in many similar forms for a variety of applications but only the C Breeze Fog Fluid meets the purity and pharmaceuti cal grade quality appropriate for the C Breeze Fogger The use of other chemicals will invalidate the product warranty and may be dangerous to your health Propylene Glycol is an additive used in many consumer and pharmaceutical products including lipstick cosmet ics processed baked goods fruit juices animal feed and veterinarian products It also creates the inhaled mist that is found in many e cigarette devices When propylene glycol is used in pharmaceutical applications strict specifications for qual ity as laid out in the European Pharma copoeia have to be followed This official document of the European Directorate for the Quality of Medicines EDQM is used in more than 37 countries in Europe In the US propylene glycol is listed as GRAS Generally Recognized as Safe for use in food and pharmaceuticals in the US Pharmacopoeia Ref21CFR the official FDA US Food amp Drug Administration documen
10. t It has been extensively studied and its toxicology has been summarized in a SIDS Initial Assessment Report SIAR with a recommendation for no additional study Derivatives of Propylene Glycol are also used in Automotive Antifreeze Com mercial Cooling Systems and de icing of planes in the Aerospace Industry Be sure to use only Degree Controls Inc Fog Fluid in your C Breeze device Proper use of the C Breeze Fog Fluid is safe and harmless to individuals Refer to the C Breeze User Manual and MSDS Material Safety Data Sheet included in your kit or download it on line at www degreeC com C Breeze User Manual 2013 Degree Controls Inc 6 About Us Degree Controls Inc has been measuring air velocity and illustrating Airflow since 1997 Our expertise is proven and well known within the Medical Telecommunications and Building Services industries As Air Visualization experts we quantify airflow with empirical data acquisition systems and optical recognition We have a complete line of environmental sensors DAQ software applications and handheld instruments to help you measure the air around you Certifiers e Help your clients upgrade existing equipment to meet ATM2400 amp regulatory standards USB Series Sensors Validate thermal amp airflow models quickly amp accurately Measure air amp temperature in e Integrate multiple feature specific airflow alarm systems at lower overal
11. the receiver from the C Breeze when not in use If you wish to maintain Momentary position so the fog generation will only produce fog when the fog button on the handle is depressed leave the Slide Switch in the position detailed above If you require the fog button on the machine to latch on put the Slide Switch away from the reservoir in the Toggle position Remote Control Operation If you require the fog button on the machine to latch on put the Slide Switch away from the reservoir Performance Notes e All fog machines develop condensation around the output nozzle e The C Breeze may produce small puffs of fog occasionally during operation and for a minute or so after being turned off This is normal and is not indicative of a defect e After continuous operation the exterior of the C Breeze will become warm especially at the front of the machine Take care in handling the machine during and shortly after fogging Only carry the C Breeze by the handle and let the machine cool down before packing it in the carry case As the battery becomes discharged and weaker a pumping noise or puffing of fog may become more prominent 5 2013 Degree Controls Inc C Breeze User Manual Specifications Output 2 3 m 100 ft per minute Power Consumption 75 W Tank Capacity 110 cc 3 7 oz Battery Supplied 12V DC 2 3Ah Consumption 2 cc 0 07 oz per minute Weight 2 7 kg 95 oz Dimension
Download Pdf Manuals
Related Search
Related Contents
Philips RI4495 Philips Salon Essential HP8107 je regroupe mes assurances et j`en suis récompensé DIV Series Sine-Wave Inverter System Manual YFZ450W Owner`s Manual Wunderlich Anbauhilfe User Manual Full Leg Spine SW Manual Cornelius Door Latch User's Manual Válvula seca FireLock NXT™ I-768-SPA Copyright © All rights reserved.
Failed to retrieve file