1. Time title Enable OSD transparent 128 Channel title Enable OSD transparent 128 Record Setup Channel Ch01 Pre record 5 seconds Time Setup Start Time 0 00 00 End Time 23 59 59 Record Period 1 Enable motion detection alarm Snapshot Period 1 Enable motion detection alarm Week Sunday COM Setup Option COMO01 Function General Data bit 8 Stop bit 1 Baud rate 115200 Parity None Network Setup Ethernet Port 01 DHCP Disable IP address 192 168 1 108 Subnet mask 255 255 0 0 Gateway 192 168 0 1 Device name Device factory default name TCP port 37777 HTTP port 80 UDP port 37776 Network user connection 10 amount Network transmission QoS Disable Remote host Multiple broadcast group Enable Disable 10 IP address 239 255 42 42 Port 36666 Email setup Enable Multiple DDNs Disable NAS setup Disable NTP setup Disable Alarm server Disable Alarm Setup Event type Local alarm Alarm input Input 01 disable Type Normal open Setup Period Start time 0 00 00 End time 23 59 59 Period 1 enable Week Sunday Anti dither 0 second General output Disable Alarm latch 10 seconds Record channel 1 enable Record latch 10 seconds Send email Disable PTZ activation Disable Event type never Address 0 Snapshoot Disable Video Detection Event type Motion detection Channel Ch01 Disable Sensitivity 3 Time period setup Period Start time 0 00 00 End time 23 59 59 Period 1 enabl
2. 53 ADDTIONAL FUNCTION Local Alarm v Input 01 y Type Normal Open v W Capture Refresh Figure 2 5 16 3 Installation This series IPC can be put on the table to realize surveillance Or you can use the bracket or the in ceiling installation to realize the hang function Please refer to the steps listed below 3 1 Device Installation Step 1 Use the inner hexagonal wrench provided to loose the three inner hexagon screws in the dome cover and then open the cover See Figure 3 1 Figure 3 1 Step 2 Use the inner hexagonal wrench provided to loose the three inner hexagon screws in the dome and then remove the device pedestal See Figure 3 2 17 Figure 3 2 Step 3 Draw out the cable exit and four screw holes in the installation position according to the device pedestal Dig the four plastic expansion bolt hole and cable exit Insert the four plastic expansion bolts into the screw holes Step 4 Adjust the camera pedestal to the proper position and then draw the cable through the cable exit you just dug in the ceiling wall Line up the four screw holes in the device pedestal to the four plastic expansion bolt holes in the installation position Put the four self tapping screws in the device pedestal and then use the screwdriver to secure the screws in the four plastic expansion bolts firmly Step 5 Adjust the device position and line up the three inner hexagon screws of the devi
3. 5 v Zoom gt Focus ESA lt CD 6 E E E E Es Figure 5 4 Please refer to the Outdoor IPC Web Operation Manual V1 0 included in the resource CD for detailed operation instruction 27 6 FAQ can not boot up Please click RESET button for at least five seconds to restore the device factory default setup SD card write Do not set the SD card as the storage media to storage the times schedule record file It may damage the SD card duration can not use the When disk information is shown as hibernation or capacity is 0 disk as the storage please format it first Via Web media can not upgrade the device via network When network upgrade operation failed you can use port 3800 to continue upgrade Recommended SD Kingston 4GB Kingston 1GB Kingston 16GB Transcend card brand 16GB SanDisk 1G SanDisk 4G Usually we recommend the 4GB or higher high speed card in case the slow speed results in data loss Audio function Please use active device for the audio monitor input otherwise there is no audio in the client end To guarantee After you modified the important setup please reboot the device via setup update the software to make sure the setup has been updated to the storage medium Power adapter The power adapter included in the accessories bag can work ranging from 0 C to 40 C The device may result in unstable power supply when the temperature exceeds the working tempe
4. DNS 8 8 8 8 Alternative DNS 8 8 8 8 12 2 Structure 2 1 MD9M Data Converter Cable You can refer to the following figure for MD9M data converter cable information See Figure 2 1 Figure 2 1 Please refer to the soa sheet for detailed ee EI output Output analog video signal It can connect to the VIDEO YUT eee TV monitor to view the video AUDIO IN Audio input RCA Input audio signal It can receive the analog audio port signal from the pickup Audio output Output audio signal to the devices such as the 12V DC AC24V a input DN Power port Input DC 12V AC 24V MO I O cable port Il Connect to MD9M data converter cable Connect to MD9M data converter cable to MD9M data converter cable Network port ca Connect to standard Ethernet cable Please refer to the follow sheet for detailed information of MD9M data converter cable Port Name Cable Name Note Color I O Port RS485_A RS485_A port It is to control the PTZ Pin RS485_B RS485_B port It is to control the PTZ Red ALARM_COM Alarm output public port Brow ALARM IN1 Alarm input port 1 It is to receive the on off signal from the external alarm source Grey ALARM_IN2 Alarm input port 2 It is to receive the on off signal from the external alarm source 13 Port Name Cable Name Note Color Alarm output port It is to output the alarm signal to the alarm device White ALARM_NO NO normal open alarm output port It works with the AL
5. IPC has connected to the network properly e IPC IP address and PC IP address shall be in the same network segment IPC default IP address is 192 168 1 108 If there is router please set the corresponding gateway and subnet mask Use order ping IP camera address to check connection is OK or not 5 2 Login and Main Interface Open IE and input IP camera address in the address bar For example if your camera IP is 192 168 1 108 then please input http 192 168 1 108 in IE address bar See Figure 5 1 Blank Page Windows Internet Explorer JO E assu we de blark Page Input your IP gt address here Internet E 100 gt Figure 5 1 System pops up warning information to ask you whether install control webrec cab or not Please click OK button system can automatically install the control When system is upgrading it can overwrite the previous Web too If you can t download the ActiveX file please check whether you have installed the plug in to disable the control download Or you can lower the IE security level See Figure 5 2 25 Internet Options ES Security Settings Internet Zone General Security Privacy Content Connections Programs Advanced Settings O Disable Select a zone to view or change security settings O Enable a a 19 Download signed ActiveX controls not secure to Y E O Disable Internet Local intranet Trusted
6. 10 C 55 C Working Humidify 10 90 Dimensions 160x118 5 Weight 1 25g Installation Support various installation modes Enclosure and bracket is optional 1 3 2 Factory Default Setup Please refer to the following sheet for factory default setup information Function Configuration Item Name Default setup Type HDB HDBW3300P HDB HDBW3300N Series Series General Setup Date format Y M D DST Date separator Disable by default Time format 24H Language Simplified Chinese When HDD is full Overwrite Record duration 60M Device No 8 Video type PAL Encode Main Channel Channel01 Setup Stream Encode mode H 264 Audio Video enable Enable audio and video General bit stream General bit stream Resolution 1080P Frame rate 25 30 Bit stream control CBR Quality Good Bit stream value 8192 frame interval control 50 Extra Extension Stream General bit stream Stream Audio Video enable Enable audio and video Resolution D1 Frame rate 25 15 Bit stream control CBR Quality Good Bit stream value 2048 frame interval control 50 Image Color Brightness 50 Contrast 50 Sautratioon 50 Hue 50 Gain 50 Disable Watermark Enable Privacy Mask Watermark all Watermark type character Watermark DigitalCCTV Never
7. ARM_COM port It is to restore factory default setup When the device is working properly please Blue RESET connect the blue cable restore default setup port to the orange cable GND signal for 5 seconds the device can resume factory default setup Ground por 2 2 Framework and Dimension Please refer to the following two figures for dimension information The unit is mm See Figure 2 2 and Figure 2 3 Figure 2 2 14 2 3 Bidirectional talk 2 3 1 Device end to PC end Device Connection Please connect the speaker or the pickup to the first audio input port in the device rear panel Then connect the earphone or the sound box to the audio output port in the PC Login the Web and then enable the corresponding channel real time monitor Please refer to the following interface to enable bidirectional talk ES cam 1 Open All Refresh StarntDialog Y Local Play Figure 2 4 Listening Operation At the device end speak via the speaker or the pickup and then you can get the audio from the earphone or sound box at the pc end 2 3 2 PC end to the device end 15 Device Connection Connect the speaker or the pickup to the audio output port in the PC and then connect the earphone or the sound box to the first audio input port in the device rear panel Login the Web and then enable the corresponding channel real time monitor Please refer to the above interface Figure 2 4 to enable bidirectional talk Listening Oper
8. HD IR Vandal Proof IP Dome Camera User s Manual Version 1 0 Welcome Thank you for purchasing our IP camera This user s manual is designed to be a reference tool for your system Please read the following safeguard and warnings carefully before you use this series product Please keep this user s manual well for future reference Important Safeguards and Warnings 1 Electrical safety All installation and operation here should conform to your local electrical safety codes The power shall conform to the requirement in the SELV Safety Extra Low Voltage and the Limited power source is rated 12V DC or 24V AC in the IEC60950 1 We assume no liability or responsibility for all the fires or electrical shock caused by improper handling or installation We are not liable for any problems caused by unauthorized modification or attempted repair 2 Transportation security Heavy stress violent vibration or water splash are not allowed during transportation storage and installation 3 Installation Do not apply power to the camera before completing installation Please install the proper power cut off device during the installation connection Always follow the instruction guide the manufacturer recommended 4 Qualified engineers needed All the examination and repair work should be done by the qualified service engineers We are not liable for any problems caused by unauthorized modifications or attempted repair 5 Envir
9. ation At the PC end speak via the speaker or the pickup and then you can get the audio from the earphone or sound box at the device end 2 4 Alarm Setup The alarm interface is shown as in Figure 2 5 Please follow the steps listed below for local alarm input and output connection 1 Connect the alarm input device to the alarm input port grey or brown pin of I O port cable 2 Connect the alarm output device to the alarm output port White pin and alarm output public port Red pin The alarm output port supports NO normal open alarm device only 3 Open the Web go to the Figure 2 5 Please set the alarm input 01 port for the brown pin the 1 channel of I O port cable The alarm input 02 is for the grey pin the 2 channel of I O port cable Then you can select the corresponding type NO NC 4 Set the WEB alarm output The alarm output port of the alarm output 01 device The white pin of the I O port cable Configuration E Control Panel Bf Query System Info Rf VERSION Rf HDD INFO Ef LOG System Config 3 GENERAL i Da ENCODE Period Anti dither 0 sec 07600 a SCHEDULE Y Normal Out Da R5232 Da NETWORK ALARM Latch fi sec 107300 Y Alarm Upload a DETECT a PANITILTIZOOM v Record Channel La DEFAULT BACKUP Record Latch o sec 107300 gt gt ADVANCED ES E HDD MANAGEMENT Y Send Email a ABNORMITY E Alarm 1 0 Config a Record V PTZ Activation a ACCOUNT a SNAPSHOT E AUTO MAINTENANCE
10. atistics log and software version lt Image Sensor 1 2 8 inch CMOS Pixel 2048 H 1536 V O y o Support day night mode switch and IR CUT at the same time 3 Auto Iris DC drive 2 Gain Control Fixed Auto White Balance Manual Auto Acta Manual Auto It ranges from 1 50 to 1 10000 ode Video Compression H 264 JPEG Standard PAL Main stream 2048 1536 15fps extra stream D1 12fps Video Frame Main stream 1920 1080 25fps extra stream D1 25fps Rate NTSC Main stream 2048 1536 15fps extra stream D1 12fps Main stream 1920 1080 30fps extra stream D1 15fps Video Bit Rate 160k 8Mbps Support customized setup 5 Does not su rt mirror pice SII suino funtion Video Quality 1 6 level The 6 level has the highest quality Snapshot Max 1f s snapshot File extension name is JPEG Privacy Mask Supports max 4 privacy mask zones Video Setup Support parameter setup such as bright contrast Moie Channel title time title video loss motion detect privacy mask Lens 4 5 10mm F1 6 Lens Interface C CS lens is the default accessories Audio Input 1 channel LINE IN Audio Output 1 channel 3 5mm JACK SPEAK OUT S Bidirectional Talk Input Reuse the first audio input channel Audio Bit Rate 8kbps 16BIT Audio Compression Standard G 711a G 711u PCM Motion Detect 396 18 22 detection zones sensitivity le
11. ce to the three holes of the installation position Put the three inner hexagon screws into the screw holes at the bottom of the pedestal Use the inner hexagon screwdriver to fix firmly See Figure 3 3 18 N EST Tag TZ Figure 3 3 Step 6 Adjust the X Y Z axis module to turn the device to the proper monitor angle Please follow the steps listed below to adjust e Slightly loose the screws at the two sides of the X Y Z module manually you can adjust the module tilt rotation angle 15 90 e Slightly loose the screw of the pressing slice you can adjust the video rotation angle of the module 0 355 e Adjust the turning ring of the pedestal you can adjust the module pan rotation angle 0 355 2 Please note the screws in the following figure are the optical adjustment component Please make sure it is outward and do not allow it to touch the X Y Z axis module See Figure 3 4 Figure 3 4 Step 7 Put the dome cover back and then put the three inner hexagon screws into the holes of the device Use the inner hexagonal wrench to fasten these three screws See Figure 3 5 19 Figure 3 5 3 2 SD Card Installation Important Before you install the SD card please unplug he power cable to shut down the device First please refer to the step1 in the chapter 3 1 to open the device Second please adjust the proper position to install the SD card Last please refer to the step 7 in the cha
12. corresponding information to login 255 255 0 0 255 255 0 0 255 255 0 0 255 255 0 0 255 255 0 0 255 255 0 0 255 255 0 0 255 255 0 0 10 7 0 1 52 54 40 52 54 40 52 54 40 00 05 23 52 54 40 00 12 26 D0 1a 6b 00 09 30 SN IP Address Subnet Mask Default Gat Mac Address 90 5d 1 d 58 e4 1 d 58 51 16 24 48 1 a 35 37 145 23 65 90 57 db ad 00 12 Figure 4 1 Refresh R Login L Logout C Select one IP address and then right click mouse you can see an interface is shown as in Figure 4 2 ConfigTool Device List SN IP Address Subnet Mask Default Gat Mac Address 10 7 6 47 3TTTT 10 7 8 21 3TTTT 10 7 10 104 3TTTT 10 7 2 2 3TTTT 10 7 1 113 3TTTT 10 7 10 91 192 168 0 108 10 7 2 61 Tip You can click login button directly and then input corresponding information to login 255 255 0 0 255 255 0 0 255 255 0 0 255 255 0 0 255 255 0 0 255 255 0 0 255 255 0 0 255 255 0 0 52 54 40 52 54 40 52 54 40 00 05 23 90 5d d 58 e4 fd 58 51 16 24 48 fa 35 37 45 23 65 90 57 db ad 00 12 Figure 4 2 Refresh R Login L Logout C 22 Select the Open Device Web item you can go to the corresponding web login interface See Figure 4 3 SIE http 10 10 3 16 AMAS i Po We de wensenie i ED BG A iy Pago O Tos Done Ci internet 4 100 gt Figure 4 3 If
13. e Week Sunday Anti dither 5 seconds General output Disable Alarm latch 10 seconds Record channel Disable Record latch 10 seconds Send email Disable PTZ activation Event type Never Address 0 Disable Snapshot Disable PTZ Setup Channel Ch01 Protocol DH SD1 Address 1 Baud rate 115200 Data bit 8 Stop bit 1 Parity None Default and Backup All Disable General Disable Encode Disable Record Disable COM Disable Network Disable 11 Alarm Disable Video detection Disable Display output Disable Channel No Disable Advanced Record control Auto Ch1 This series device does not support this function Abnormity Even Type No HDD Disable General Disable Output Alarm Latch 10 seconds Send email Disable User account admin password admin reusable 888888 password 888888 reusable 666666 password 666666 reusable default password tluafed Snapshot Channel Cho1 Snapshot Scheduled mode Frame rate 1f s Resolution 1080P Quality 80 Auto Auto reboot 2 00 each day maintain Auto delete Never old files Camera Property Channel 1 Exposure Mode Auto Day Night Mode Auto White Balance Auto Scene Mode Auto Signal Type Internal input Mirror N A Flip Support Auto Registration Enable Disable SN 1 IP 0 0 0 0 Port 7000 Device ID None DNS Setup
14. eeded pei Max supports 10 connections Adopt the following audio and video transmission protocol HTTP TCP UDP MULTICAST and RTP RTCP and etc Support web access widely used in WAN Network e Realize IPC configuration and management via Ethernet Management Support device management via web or client end e Support peripheral equipment management each peripheral equipment Peripheral control protocol and interface can be set freely Equipment Support serial port RS232 RS485 transparent data transmission External power adapter DC12V AC 24V Power Log function Assistant Support PAL NTSC Function Support system resource information and running status real time display Day Night mode auto switch Built in IR light Support IR night vision Backlight compensation screen auto split to realize backlight compensation to adjust the bright Support electronic shutter and gain setup Support video watermark function to avoid vicious video modification 1 3 Specifications 1 3 1 Performance Please refer to the following sheet for IPC performance specification wa SAS Main Processor HDB HDBW3300P N TI Davinci high performance DSP OS Embedded LINUX System Resources Support real time network local record and remote operation at the same time User Interface Remote operation interface such as WEB DSS PSS System Status SD card status bit stream st
15. ents General Introduction eee iene 7 1 1 OVEnMiIeWi csisrniiioze Pi liti radiolina diletta desidia 7 1 2 Features a RR IRR cattle etek 7 1 3 SPECIHCAUONS aan o 8 ll R ilaele E EEEE eni a EEEE 8 1 3 2 Factory De A de 9 A RENA 13 2 1 MD9M Data Converter Cable eee 13 2 2 Framework and DIMENSION iene 14 2 3 Bidirectional alko ass aelred ds Bee 15 2 3 1 Device end to PC end ie eee 15 2 3 2 PC end to the device end ooooocccccncccocononoconccccncnononnononcnnnncnononnnnonnnnnncnononannonennnss 15 2 4 A O 16 Installation a SE EIR SE MEIC a BE 6 ALIENS cla SEO I AM 17 3 1 Device Installation eel cae el a ed Sell as Get dea a ai 17 3 2 SD Gard Installati n 0 omnia ti 20 3 3 Lens AUS Me Esad aia al E 21 QUICK COMMGUPAUOM TOON sia a aia iii ia 22 4 1 OV ERVICW Sectors ote RTD ec IRA 22 4 2 E 22 Web Operaio A AS 23 5 1 Network Connectionin al a e ee de ili lire bi 25 5 2 Login and Main INTETTACO oia A a A A easuas 23 1 General Introduction 1 1 Overview This series IP camera integrates the traditional camera and network video technology lt adopts audio and video data collection transmission together It can connect to the network directly without any auxiliary device This series IPC uses standard H 264 video compression technology and G 711a audio compression technology which maximally guarantee the audio and video quality This series IPC enclosure has the st
16. n notice e If there is any uncertainty or controversy please refer to the final explanation of us e Please visit our website for more information 29
17. onment This series IP camera should be installed in a cool dry place away from direct sunlight inflammable explosive substances and etc Please keep it away from the electromagnetic radiation object and environment Please make sure the CCD CMOS component is out of the radiation of the laser beam device Otherwise it may result in CCD CMOS optical component damage Please keep the sound ventilation Do not allow the water and other liquid falling into the camera 6 Daily Maintenance Please shut down the device and then unplug the power cable before you begin daily maintenance work Do not touch the CCD CMOS optic component You can use the blower to clean the dust on the lens surface Always use the dry soft cloth to clean the device If there is too much dust please use the water to dilute the mild detergent first and then use it to clean the device Finally use the dry cloth to clean the device Please put the dustproof cap to protect the CCD CMOS component when you do not use the camera 7 Accessories Be sure to use all the accessories recommended by manufacturer Before installation please open the package and check all the components are included Contact your local retailer ASAP if something is broken in your package Accessory Name Amount IPC Unit MD9M data converter cable Accessories bag Quick Start Guide Warranty Card Certificate Card CD 1 Table of Cont
18. pter 3 1 to complete the installation See Figure 3 6 Figure 3 6 20 3 3 Lens Adjustment Step1 Slightly loose the screw B manually and then turn the screw B slowly Adjust the lens focus distance to the proper position according to the monitor video See Figure 3 7 Step 2 Use the flat screwdriver to loose the screw A slightly and then turn the Screw A slowly Adjust the lens focus to get the clear video and then use the flat screwdriver to secure the screw firmly Step 3 When you are adjusting the screw A the video may becomes blur Please slightly adjust the screw B manually to get the vivid video Finally fix the screw Screw A Screw A Lens focus Screw B Lens zoom Figure 3 7 21 4 Quick Configuration Tool 4 1 Overview Quick configuration tool can search current IP address modify IP address At the same time you can use it to upgrade the device Please note the tool only applies to the IP addresses in the same segment 4 2 Operation Double click the ConfigTools exe icon you can see an interface is shown as in Figure 4 1 In the device list interface you can view device IP address port number subnet mask default gateway MAC address and etc ConfigTool Device List 10 7 6 47 10 7 8 21 10 7 10 104 3TTTT 10 7 2 2 3TTTT 10 7 1 113 3TTTT 10 7 10 91 3TTTT 192 168 0 108 10 7 2 61 3TTTT 1 2 3 4 5 6 T 8 Tip You can click login button directly and then input
19. rature Please replace an industry level power adapter if you are using in the harsh environments Appendix Toxic or Hazardous Materials or Elements Toxic or Hazardous Materials or Elements Component Mame Pb Hg Cd Cr VI PBB PBDE Circuit Board z M gt A A Component Device Construction o o o o o o Material Wire and Cable o o o o o o Packing 3 A n a A 4 Components Accessories o o o o o o O Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ T11363 2006 standard X Indicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ T11363 2006 standard During the environmental friendly use period EFUP period the toxic or hazardous substance or elements contained in products will not leak or mutate so that the use of these substances or elements will not result in any severe environmental pollution any bodily injury or damage to any assets The consumer is not authorized to process such kind of substances or elements please return to the corresponding local authorities to process according to your local government statutes Note e This user s manual is for reference only Slight difference may be found in user interface e All the designs and software here are subject to change without prior writte
20. rong resistance capacity which can guarantee the proper work performance under heavy strike It supports real time monitor and listening at the same time It supports analog video output and dual way bidirectional talk It can be used alone or used in a network area When it is used lonely you can connect it to the network and then use a network client end Due to its multiple functions and various uses this series IPC is widely used in many environments such office bank road monitor and etc 1 2 Features User Different user rights for each group one user belongs to one group The user right shall not exceed the group right Management Support central server backup function in accordance with your configuration and setup in alarm or schedule setting Storage Support record via Web and the recorded file are storage in the client Function ond PO area e Support built in SD card e Support local SD card hot swap support short time storage when encounter disconnection Real time respond to external local alarm input and video detect within Alarm 200MS as user pre defined activation setup and exert corresponding Function message in screen and audio prompt allow user to pre record audio file Real time video detect motion detect camera masking video loss e IPC supports one channel audio video data transmit to network terminal and then decode Delay is within 350ms network bandwidth support n
21. sites Y Enable not secure a ji dl O Prompt recommended Internet 19 Download unsigned ActiveX controls not secure This zone is for Internet websites stes O Disable recommended except those listed in trusted and O Enable not secure restricted zones O Prompt Security level For ti zone al pa script ee not marked as safe For s Allowed levels for this zone Medium to High ae aay Medium high gt O Prompt punto lec e ESO unsafe Y Run ActiveX controls and plug ins content O fidminictrator armenvad Unsigned Activex controls will not be downloaded lt Ju Takes effect after you restart Internet Explorer Default level Reset custom settings Reset to medium high default Reset all zones to default level T Figure 5 2 After installation the interface is shown as below See Figure 5 3 Please input your user name and password Default factory name is admin and password is admin Note For security reasons please modify your password after you first login WEBservice Windows Internet Explorer E IG x DA SO E ht n0 10316 i 9 9 gt lt ex Jet amp wesservice iM D gt rage Gtoas gt Done Cd Internet 100 Figure 5 3 After you logged in you can see the main window See Figure 5 4 26 WEB service SEARCH CONFIG LOGOUT Open All Refresh StariDialog Y Local Play Speed 1 8
22. vel ranges from 1 to 6 The 6 level has the highest sensitivity Activation event alarm device audio video storage image snapshot log email SMTP function and etc Video Loss Alarm Input Activation event alarm device audio video storage image snapshot log email SMTP function and etc 2 channel input 1 channel output on off pue p1099 Priority Manual gt Alarm gt Motion detect gt Schedule Record Search Mode Support local data search via time date event type alarm motion detect external alarm and file type record image Local Storage Support Micro SD card hot swap Storage Management Support display local storage status Z D Oo x Wire Network 1 channel wire Ethernet port 10 100 Base T Ethernet Network Protocol Standard HTTP TCP IP ICMP RTSP RTP UDP RTCP SMTP FTP DHCP DNS DDNS PPP OE Remote Operation Monitor PTZ control playback system setup file download log information maintenance upgrade and etc 298 19 U XNW 1991 18 e19U25 Video Output 1 channel analog video output BNC port 9 pin port connection Reset 9 pin port connection IR light 35 LED IR distance 10 to 20 meters For HDBW series product only RS485 port PTZ control interface Support various protocols Power Support AC24V DC12V power Power Consumption 7W MAX When the ICR is on 8 5W MAX Working Temperature
23. you want to modify the device IP address without logging in the device web interface you can go to the configuration tool main interface to set In the configuration tool search interface Figure 4 1 please select a device IP address and then double click it to open the login interface Or you can select an IP address and then click the Login button to go to the login interface See Figure 4 4 In Figure 4 4 you can view device IP address user name password and port Please modify the corresponding information to login Please note the port information here shall be identical with the port value you set in TCP port in Web Network interface Otherwise you can not login the device If you are use device background upgrade port 3800 to login other setups are all invalid IP Address 10 10 3 16 User Name admin Password prota Port arTTT Figure 4 4 After you logged in the configuration tool main interface is shown as below See Figure 4 5 23 ConfigTool Figure 4 5 24 5 Web Operation This series IPC product support the Web access and management via PC Web includes several modules includes monitor channel list record search alarm setup system configuration PTZ control monitor window and etc IP camera factory default setup e IP address 192 168 1 108 Username admin Password admin 5 1 Network Connection Please follow the steps listed below for network connection Make sure the