1. 1K 2K 3K with Isolation Transformer Online UPS Uninterruptible Power Supply System Table of Contents 1 IMPORTANT SAFETY WARNING ciar 2 A ist k I ic 2 1 2 PRED AFAU OM sisne nie ES A rv 2 15 Y EE 5181 q PPC PEO o o 2 54 ODO nasa 2 1 5 Maintenance service and FaUItS c ccecescucucucucucusueususesuseseueueueuuuuuauauaueueueueueuenenanas 3 2 INSTALLATION AND SETUP nia AA 4 Zl Rear A PP e UE CO E tes a aa 4 2 2 Setup thle UPS rad 6 SL OPERATION Sa 8 3 1 BUON op ratiO ermano 8 352 LEP Foa I 8 3 3 AUDIO AlI enoarm ana 10 SA ECD display WONGINGS Md iaa 10 3 5 UPS SEUNG ii ias 10 3 6 Operating Mode Description ccccssecsscuseusscuscusecuseuseeuscuseeureusecusausecueausecueausesuss 13 3 72 Faults Refererce COMO ia 14 350 Watling MACIO unaa a a 14 A TROUBLESHOOTIN Gi 15 3 STORAGE AND MAINTENANCE Sii 17 O SPECIFICATIONS s 18 1 Important Safety Warning Please comply with all warnings and operating instructions in this manual strictly Save this manual properly and read carefully the following instructions before installing the unit Do not operate this unit before reading through all safety information and operating instructions carefully 1 1 Transportation Please transport the UPS system only in the original package to protect against shock and impact 1 2 Preparation e Condensation may occur if the UPS system is moved directly from cold to warm environment The UPS system must be absolutely
2. Default 264VAC LLS Bypass low voltage point 170 220 setting the low voltage point from 170VAC to 220VAC Default 170VAC 0 999 Setting the backup time in minutes from O to 999 for general outlets in battery mode 0 When setting as 0 the backup time will be only 10 seconds 999 When setting as 999 backup time setting will be disabled Default Press the Down key or Up key to set the acceptable high frequency point and acceptable low frequency point HLS Line high voltage point LLS Line low voltage point For 50Hz output frequency models 51 55Hz setting the high frequency point from 51Hz to 55Hz default 53Hz 45 49Hz setting the low frequency point from 45Hz to 49HZ default 4 HZ For 60Hz output frequency models 61 65Hz setting the high frequency point from 61Hz to 65Hz default 63Hz 55 59Hz setting the low frequency point from 55Hz to 59Hz default 5 7Hz e 11 Battery AH setting Press the Down key or Up key to set the Battery AH of UPS 0 999 if you change the battery AH of ups please set the correct battery spec Unit AH 3 6 Operating Mode Description Operating mode LCD display Online mode When the input voltage is within acceptable range UPS will provide pure and stable AC power to output The UPS will also charge the battery at online mode ECO mode Energy saving mode When the input voltage is within voltage regulation range UPS wi
3. lal 1a mar della Ble ny 8 1 aa A A formy aa 5 w IEC Type NEMA Type 2 2 Setup the UPS Step 1 UPS input connection Plug the UPS into a two pole three wire grounded receptacle only Avoid using extension cords The input plug is a 18 3C for 1KVA 2KVA 16 3C for 3KVA Step 2 UPS output connection Simply plug devices to output sockets During power failure UPS will provide power to connected devices Step 3 Communication connection Communication port RS 232 port Intelligent slot To allow for unattended UPS shutdown start up and status monitoring connect the communication cable one end to the RS 232 port and the other to the communication port of your PC With the monitoring software installed you can schedule UPS shutdown start up and monitor UPS status through PC This UPS is equipped with intelligent slot perfect for SNMP RS 232 USB or AS 400 card When installing with these communication card in the UPS it will provide advanced communication and monitoring options Step 1 ly Step 2 Us Step 3 Remove cover of intelligent Insert communication card Screw card tightly a and slot into the slot complete installation Step 4 Network connection Network Fax Phone surge por IN OUT Connect a single modem phone fax line into surge protected IN outlet on the back panel of the UPS unit Connect from OUT outlet to the equipment with another modem fa
4. dry before being installed Please allow at least two hours for the UPS system to acclimate the environment e Do not install the UPS system near water or in moist environments e Do not install the UPS system where it would be exposed to direct sunlight or near heater e Do not block ventilation holes in the UPS housing 1 3 Installation e Do not connect appliances or devices which would overload the UPS system to the UPS output sockets Place cables in such a way that no one can step on or trip over them The UPS can be operated by any individuals with no previous experience e Connect the UPS system only to an earthed shockproof outlet which must be easily accessible and close to the UPS system Please use only VDE tested CE marked mains cable e g the mains cable of your computer to connect the UPS system to the building wiring outlet shockproof outlet Please use only VDE tested CE marked power cables to connect the loads to the UPS system When installing the equipment it should ensure that the sum of the leakage current of the UPS and the connected devices does not exceed 3 5mA 1 4 Operation e Do not disconnect the mains cable on the UPS system or the building wiring outlet shockproof socket outlet during operations since this would cancel the protective earthing of the UPS system and of all connected loads e The UPS system features its own internal current source batteries The UPS output sockets or o
5. jf O 8 User type Administrator lt i a Monitored UPS 192 168 102 72 gt USB id 15A5C289 PO1 gt JP CURRENT Local shutdown Remote shutdown Parameters setting Purchasing information b A LAN P INTERNET Alarm at bypass mode e Enable Disable Green power function Enable Disable Alarm at battery mode Enable Disable Cold start Enable Disable Auto reboot Enable _ Disable Bypass not allowed _ Enable Disable Bypass when UPS is off _ Enable Disable Battery deep discharge protection Enable _ Disable Converter mode Enable Disable Site fault detection Enable Disable ECO mode _ Enable Disable P1 programmable outlet control battery mode Enable Disable Advanced ECO mode Outlet setting Battery numbers setting Backup time for P1 battery mode 999 m Min Numbers in parallel 1 Voltage and frequency range for bypass mode Voltage range for ECO mode Maximum voltage 264 lv V Maximum voltage 242 V Minimum voltage 170 V Minimum voltage 218 V Maximum frequency 51 2 bad Hz Minimum frequency 46 6 Hz Default 3 Operations 3 1 Button operation gt Turn on the UPS Press and hold ON Mute button for at least 2 seconds to turn on the UPS gt Mute the alarm After the UPS is turned on in battery mode press and hold this button for at least 5 seconds to disable or enable the alarm system But it s not applied to the situations when warn
6. 40 presents output voltage is 240VAC CF ENA converter mode enable CF DIS converter mode disable Default You may set the initial frequency on battery mode BAT 50 presents output frequency is 50HZ Default BAT 60 presents output frequency is 60HZ If converter mode enable you may choose the following output frequency CF 50 presents output frequency is 50HZ Default CF 60 presents output frequency is 60HZ Press the Down key or Up key to set the acceptable high voltage point and acceptable low voltage point of the input HLS High loss voltage in Line mode The setting range is from 260VAC to 300VAC Default 300VAC LLS Low loss voltage in Line mode The setting range is from 160VAC to 190VAC Default 160VAC ENA ECO mode enable DIS ECO mode disable Default 11 e 06 ECO voltage range setting Press the Down key or Up key to set the acceptable high voltage point and acceptable low voltage point HLS High loss voltage in ECO mode The setting range is from 7V to 24V of the nominal voltage Default 12V LLS Low loss voltage in ECO mode The setting range is from 7V to 24V of the nominal voltage Default 12V ENA Bypass mode enable DIS Bypass mode disable Default Press the Down key or Up key to set the acceptable high voltage point and acceptable low voltage point HLS Bypass high voltage point 230 264 setting the high voltage point from 230VAC to 264VAC
7. Operation Humidity 20 90 RH 0 40 C non condensing T oise Level Less than 45dBA O 1 Meter Less than 55dBA 1 Meter MANAGEMENT Smart RS 232 Port Card Supports Windows 2000 2003 XP Vista 2008 Windows 7 8 Linux Unix and MAC Intelligent Slot Power management from SNMP manager and web browser Derate capacity to 80 when the output voltage is adjusted to 200 208VAC Derate capacity to 80 when the UPS in bypass mode and input voltage less than 200VAC 7 n
8. aler 86 Be sure to deliver the spent battery to a recycling facility or ship it to your dealer in the replacement battery packing material Storage Before storing charge the UPS 5 hours Store the UPS covered and upright in a cool dry location During storage recharge the battery in accordance with the following table Storage Temperature Recharge Frequency Charging Duration 25 C 40 C Every 3 months 40 C 45 C Every 2 months 17 6 Specifications INPUT Voltage based on load percentage 100 80 80 70 70 60 60 0 Hande OUTPUT 200 208 220 230 240VAC 2 47 53 Hz or 57 63 Hz Output voltage C Voltage Regulation 50 Hz 0 25 Hz or 60Hz 0 3 Hz 3 1 lt 3 Linear Load Harmonic Distortion THD a Non linear Load Transfer AC Mode to Batt Mode Zero Time Inverter to Bypass 4 ms Typical urrent Crest Ratio O gt D O c D O lt AJ OJ Ca D gJ Q cr S O O D EFFICIENCY 75 77 78 81 80 81 NM E 6 attery Numbers Standard Charging Current 1 0A max 27 4 VDC 41 0 VDC 54 7 VDC 82 1 VDC a s NA Depending on the capacity of external batteries Numbers Long run Model cnargino Current 1A 2A 4A 8A Default 1A 2A 4A 6A Default Charging Voltage 274 VDC 41 0 VDC 54 7 VDC 82 1 VDC 2 nent Standard Model Model ENVIRONMENT
9. below and any other measures necessary when working with batteries remove wristwatches rings and other metal objects use only tools with insulated grips and handles When changing batteries install the same number and same type of batteries Do not attempt to dispose of batteries by burning them This could cause battery explosion e Do not open or destroy batteries Escaping electrolyte can cause injury to the skin and eyes It may be toxic Please replace the fuse only with the same type and amperage in order to avoid fire hazards e Do not dismantle the UPS system NOTE Before installation please inspect the unit Be sure that nothing inside the package is damaged Please keep the original package in a safe place for future use 2 Installation and setup 2 1 Rear Panel View a SS A NEMA Type India Type e 15 Kia y 1 lt Schuko Type 0000 IEC Type Schuko Type India Type NEMA Type IEC Type N a 0 O L es 24 O v g v o gt b c gt 5 v Sa px z cx i o o 3 E U Z Ge teat y O pD SS XLS QS i l m eo Z S aD SU Y D x QOQ E 3 4 o c v S g O D gt YN U poa i O 0 6 c wx O 5 s s 5 a Z 9 v ca 0 85455 cee 55 0 2 PORE DH v 0 2 V aS 3 0 53 a n A gt S O GV X E 3 S V a O lt 3 0 2 3 O O S ea ee ES ES l r S S o A A G Y A
10. ings or errors occur Up key Press this button to display previous selection in UPS setting mode Switch to UPS self test mode Press ON Mute buttons for 5 seconds to enter UPS self testing while in AC mode Turn off the UPS Press and hold this button at least 2 seconds to turn off the UPS Confirm selection key Press this button to confirm selection in UPS setting mode Switch LCD message Press this button to change the LCD message for input voltage input frequency battery voltage output voltage output frequency and charger discharger current Select Button Setting mode Press and hold this button for 5 seconds to enter UPS setting mode when UPS is off Down key Press this button to display next selection in UPS setting mode Switch to bypass mode When the main power is normal press ON Mute Select ON Mute and Select buttons simultaneously for 5 seconds Then UPS Button will enter to bypass mode This action will be ineffective when the input voltage is out of acceptable range ON Mute Button OFF Enter Button 3 2 LCD Panel Backup Time Info Fault Info M Nb ute Operation Output Info y Battery Info BATT FAULT a Battery Info 3 ST Loadlnfo V Mode Operation Info Indicates the remaining backup time in numbers H hours M minute S second Output Battery information ma a es Indicates the output voltage frequency or battery current A L Az O Hz Vac output voltage Hz freque
11. ll bypass voltage to output for energy saving Converter mode When input voltage is within 40HZ to 70HZ the UPS can be set at a constant output frequency 50HZ or 60HZ The UPS will still charge battery under this mode gt 13 Operating mode LCD display Battery mode When the input voltage is beyond the acceptable range or power failure and alarm is sounding every 4 second UPS will backup power from battery Bypass mode When input voltage is within acceptable range but UPS is overload UPS will enter bypass mode or bypass mode can be set by front panel Alarm is sounding every 10 second Standby mode UPS is powered off and no output supply UN power but still can charge batteries 3 7 Faults Reference Code Fault event Battery voltage too high 11 0x 3 Battery voltage too low Inverter soft start fail Over temperature Inverter voltage high 12 x Overload 43 oe 3 8 Warning indicator Icon flashing 1 2 3 5 11 12 i Battery is not connected Sounding every second Over Charge Sounding every second gt gt 46 o gt Sounding every second Over temperature Sounding every second Charger failure Sounding every second Site wiring fault Battery fault TAU Sounding every second De 1 BB oo L 14 gt ES 9 a lt 4 Troubleshooting If the UPS system does not opera
12. ncy Load aran Indicates the load level by 0 25 26 50 51 75 and 76 100 Indicates overload Indicates the bypass circuit is working Indicates the ECO mode is enabled Indicates the Inverter circuit is working Indicates the output is working Indicates the Battery level by 0 25 26 50 51 75 and 76 100 Indicates the input voltage or frequency O O U Hz Vac Input voltage Hz input frequency Vdc battery voltage 3 3 Audible Alarm Battery Mode Sounding every 4 seconds Low Battery Sounding every second Sounding twice every second Fault Continuously sounding Bypass Mode Sounding every 10 seconds 3 4 LCD display wordings index Abbreviation DIS d 5 ESC H O lt O O ioe Pr YAA U TU BAT MiIC I IT UTM rr ry LIO gt Fr m I Or A a 3 5 UPS Setting There are three parameters to set up the Parameter 1 UPS Parameter 1 It s for program alternatives Refer to below table for the details Parameter 2 and parameter 3 are the setting options or values for each program Parameter 2 Parameter 3 10 e 01 Output voltage setting Settinc For 200 208 220 230 240 VAC models you may choose the following output voltage 200 presents output voltage is 200VAC 208 presents output voltage is 208VAC 220 presents output voltage is 220VAC 230 presents output voltage is 230VAC Default 2
13. t Bypass mode Connected down the UPS and restart devices are fed directly by it the mains Fault code is shown as 43 and The The UPS shut down Remove excess loads from OVER LOAD automatically because of UPS output and restart it overload at the UPS output Icon is lighting on LCD display and alarm is continuously sounding Fault code is shown as 14 and the The UPS shut down Check output wiring and if icon is lighting on LCD automatically because connected devices are in display and alarm is continuously Short circuit occurs on the short circuit status sounding UPS output 15 Symptom Fault code is shown as 01 02 03 A UPS internal fault has Contact your dealer 05 11 12 13 and 41 on LCD occurred There are two display and alarm is continuously possible results sounding 1 The load is still supplied but directly from AC power via bypass 2 The load is no longer supplied by power Battery backup time is shorter Batteries are not fully Charge the batteries for at than nominal value charged least 5 hours and then check capacity If the problem still persists consult your dealer Batteries defect Contact your dealer to replace the battery 16 5 Storage and Maintenance Operation The UPS system contains no user serviceable parts If the battery service life 3 5 years at 25 C ambient temperature has been exceeded the batteries must be replaced In this Case please contact your de
14. te correctly please solve the problem by using the table below Symptom No indication and alarm even The AC input power is not Check if input power cord though the mains is normal connected well firmly connected to the mains The AC input is connected Plug AC input power cord to the UPS output to AC input correctly A Ey l Line and neutral Rotate mains power socket The icon Land ve flashing on conductors of UPS input by 180 and then connect LCD display and alarm is sounding are reversed to UPS system every second The icon ZX and flashing The external or internal Check if all batteries are on LCD display and alarm is battery Is incorrectly connected well sounding every second connected Fault code is shown as 27 and the Battery voltage is too high Contact your dealer BATT FAULT or the charger is fault icon is lighting on LCD display and alarm is continuously sounding Fault code is shown as 28 and the Battery voltage is too low Contact your dealer BATT FAULT or the charger is fault icon is lighting on LCD display and alarm is continuously sounding The icon A aid OVER Load lt UPS is overload ao loads from jaiek g roh pacta UPS is overloaded Devices Remove excess loads from connected to the UPS are UPS output fed directly by the electrical network via the Bypass After repetitive overloads Remove excess loads from the UPS is locked in the UPS output first Then shu
15. utput terminals block may be electrically live even if the UPS system is not connected to the building wiring outlet e In order to fully disconnect the UPS system first press the OFF Enter button to disconnect the mains eo Prevent no fluids or other foreign objects from inside of the UPS system 1 5 Maintenance service and faults The UPS system operates with hazardous voltages Repairs may be carried out only by qualified maintenance personnel e Caution risk of electric shock Even after the unit is disconnected from the mains building wiring outlet components inside the UPS system are still connected to the battery and electrically live and dangerous e Before carrying out any kind of service and or maintenance disconnect the batteries and verify that no current is present and no hazardous voltage exists in the terminals of high capability capacitor such as BUS capacitors Only persons are adequately familiar with batteries and with the required precautionary measures may replace batteries and supervise operations Unauthorized persons must be kept well away from the batteries e Caution risk of electric shock The battery circuit is not isolated from the input voltage Hazardous voltages may occur between the battery terminals and the ground Before touching please verify that no voltage is present eo Batteries may cause electric shock and have a high short circuit current Please take the precautionary measures specified
16. x phone line cable Step 5 Turn on the UPS Press the ON Mute button on the front panel for two seconds to power on the UPS Note The battery charges fully during the first five hours of normal operation Do not expect full battery run capability during this initial charge period Step 6 Install software For optimal computer system protection install UPS monitoring software to fully configure UPS shutdown You may insert provided CD into CD ROM to install the monitoring software If not please follow steps below to download and install monitoring software from the internet 1 Go to the website http www power software download com 2 Click ViewPower software icon and then choose your required OS to download the software 6 3 Follow the on screen instructions to install the software 4 When your computer restarts the monitoring software will appear as an orange plug icon located in the system tray near the clock Step 7 External battery connection Follow the below chart to make external battery connection battery Step 8 External battery capacity configuration in software To calculate accurate backup time of external batteries it s necessary to configure battery numbers in software The standard calculated capacity for one battery is 9Ah If connecting to 100Ah batteries then it s equal to 11 in parallel 100Ah 9Ah x 11 sets Viewpower configuration UPS setting Control View Format Language Help u EF