Home

Diode Laser Hair Removal System 808S User Manual

image

Contents

1. Set a m El 808nm Diode Laser Hair Removal Machine LD and 12V 15V power input LD GND A 5 f Me sash Meet ee of 2 Laser driver board connect with control board 5 Machine Installation Do not power up the system before you checked this manual 1 Please check all the part in packing list to confirm all the part are received 2 Add water to water tank Please confirm your machine model 808S means the there are micro channel cooler laser stack in the handle piece It need Dl water Otherwise laser handle piece are easily broken Connect the water tube to the water inlet Use funnel to add water Observe the water level window till the water level is close to 1cm to the top of the window You may need 2 liters of water For DI water please check the degree of ions every month to make sure deionized 2 10 us cm For distilled water just change water every 3 month Do not over filled the water or there may be some water leakage 3 Connect the handle piece to main machine Check the handle piece if it is in good conditions Make sure the water tube is well connected You will hear kink when the water connector are well locked Otherwise there will be water leakage or water jam which may cause water pump broken or laser burning out 1 Please confirm if your wall plug is 200 240VAC If it is 90 120VAC please use voltage transformer 2 Find a 10A 220 250V VAC plug wire you may need a
2. follow those default just press OK Then ready and adjust skin cooling grade for treatment lf want to adjust your favourite parameter press SET then you can adjust fluence and frequency by and then touch ok ready and adjust skin cooling for treatment Bottom use recommended parameter will reset those three parameter to default 808nm Diode Laser Hair Removal Machine There are totally 3 parameters to be set including fluence Frequency and Skin Cooling Level 1 2 3 The Fluence energy density press set and fluence bracket to adjust fluence single pulse energy density it can be adjusted between 1 120J The Frequency shows the pulses per second of the laser The frequency can be variable from 1Hz 10Hz with a step width of 1Hz You can adjust it by press and The Skin Cooling Level shows cooling efficiency of the Sapphire Window and Aluminum Tip of the handle piece The green block is longer the cooling is better It depends on the feeling of the patents The default cooling level is minimum output which can be adjust by pressing and button When the laser is working you can not adjust skin cooling level You may need to wait for several minutes before the skin cooling tip becomes cold Subtotal is total for energy This will make record for this treatment output total energy It can be clear manually and it will be clear automatically by turn off machine The column be
3. 808nm Diode Laser Hair Removal Machine Diode Laser Hair Removal System 808S User Manual Model 808S 808nm Diode Laser Hair Removal Machine Index Welcome Dade a ten arte it o ese Serre cece DR A eet E areca A A O GC gest hoes RE so IG MAG E AA O sata pc caret oth O O ie de Patte Technology specification O ON OA R ON gt Basic machine structure and circuit diagram era Machine INST ON susi aida ds EO DE AO ssa E A A SORT ne EE ea A A EAA na Done v Treatment Noli ds MM fe TAN LS AS A Seas e POP E o A O RED Waranty NOICE ti A Aids O EXCODHON Fal UE il Be EO NOW DR WwW 808nm Diode Laser Hair Removal Machine 1 Attention 1 808S Diode Laser Hair Removal Machine could emit the high intensity infrared laser beam There are some operation regulation need to be follow e According to the standard of NOHD please wear the suitable protection glasses for operator and patient In order to protect the eyes Please do not point the laser at the eyes directly 2 Please make sure to be familiar with the structure and manual before operation 3 Diode Laser Hair Removal Machine is only allowed to be used by people who had enough safety and operation training Please turn off the cooling function when the machine is under the condition of standby otherwise the probe will be easily damaged 4 If this is the first time you use Diode Las
4. ater cleaned by filter in side the machine The conductivity parameter on the interface 3 will be obviously come down Then warning will disappeared If there are not any go down of conductivity for long time please ask professional technician to change the ion exchange filter inside the machine 4 Status Operation wrong Start treatment without enter ready status 5 Water pump shut off There is a thermal overload protected motor The motor will automatically shut off as temperature rises due to an overload condition If the motor shuts off in this manner close all nozzles faucets or valves After a cooling period the pump will automatically re start To avoid this problem please first make sure all the water connector are well connected Secondly open the water inlet to make the balance of air pressure between inside and outside of the water circle system then let the water pump working for a while the water flow rate should rise up 6 Water pump have noise meanwhile the water flow rate lower than expecting default Open the blue cap in front of the pump And tighten the screw in it as below picture 808nm Diode Laser Hair Removal Machine 7 Compressor don t work Make sure the switch of compressor is shut on Then check the electric wire whether there is bad connect 8 Compressor work but water temperature can t be cooled down Check the capillary tube temperature If it is warn maybe here is a freon leakage along the freon tube Pl
5. ease ask manufacture or distributor for help 9 Compressor shut on and shut off frequently Check the temperature detect switch a Whether the temperature showing on the switch is same with the number on the LCD b Press set button to see the setting temperature it should be 23 degree centigrade C Press up button to see the default range of temperature which should be 5 degree d Press up button amp set button at same time for 10 seconds then small LCD will show F1 F5 parameter Use up and down button to find F5 then press set button to see what is the number show on the LCD F5 is the temperature compensation The default temperature compensation should be 0 degree centigrade IF 14 AL ARI A m Jeratur detect switch ADA ETS compressor switch button down on off 12
6. er Hair Removal Machine please read the User Manual carefully before operation 5 Please do not use the Hair Removal Machine in the environments which contain flammable anaesthetic and Oxidizing gas such as N20 and O2 Some material such as cotton or wool textile will be ignited in the environment which is rich in oxygen during Hair Removal machine running 6 All rights reserved The content in this manual is copyrighted without permission of Oriental Laser Beijing Co Ltd any organization or individual could not copy or save them in the database or retrieval system 808nm Diode Laser Hair Removal Machine 2 Packing List 1SET Laser machine with case Pedal Smith APO User Manual APO 3 Technical Specifications Skin Cooling temperature 808nm Diode Laser Hair Removal Machine 4 System Basic Structures and Electric Diagrams Cooling Fan on the shell AC 220V Input Emergency Power Supply 1 Laser driver board stop E 600 12 15 Key switch Handle piece Power Supply 2 NES 150 12 Main control board Pump protect Compressor Cooling system Power Supply 3 Water Pump connect with laser driver board PS a po gt A E a Eco O gt O OO OOo OO Ci DO O a oO OD ed TEC power ouput 12V Control board TEC power input 12V A f water flow sensor cp out water conductivity sensor water temp sensor PT100 transmit foot petal handpiece switch HRE 1
7. low skin cooling shows the system status A Status Setting This means you are setting parameters B Status Ready When parameters have been set press READY button the system will enter Ready status In this status the laser is ready to use C Status Working When the handle piece shots laser pulses the system will enter to Working status D Status Water temperature high The cooling water temperature range should be between 15 28 C If it higher than 30 C the laser will stop Please wait till water temperature going down The warning will disappear and system can be set again E Status Water flow rate low lt means the cooling water flow rate lower than minimum requirement If the water flow rate which show at the bottom of the screen is just low not O L min Please first check along the water tube to confirm whether there are any jam in it and handle piece water connector are well locked Secondly open the water inlet at the back of machine to make the air pressure balance between the inside and outside of water circle system If the water flow rate show O L min Please first check whether the water pump are working Or contact our company to ask for help F Status Filter and deionized water need change lt means the conductivity of cooling water is higher than 20us cm Just wait for a minute till to water cleaned by filter in side the machine The conductivity parameter on the interface 3 will be obvio
8. n European Model for the wire connect to the back panel 3 Turn on the earth leakage circuit breaker at the back panel 4 Check if the emergency button is pressed down If pressed down please release it 5 Use the key to start the system and you will enter the welcome interface of the system as below 808nm Diode Laser Hair Removal Machine er WEI COME WELCOME S ee PAINFREE HAIRFREE LASER HAIR REMOVAL SYSTEM Interface 1 Interface 2 6 Press the welcome bottom you will enter the second page as the right picture above There 3 modes of functions HR hair removal FHR fast hair removal SR skin rejuvenation you will go to corresponding interface by choose different option Please follow the 6 OPERATION chapter to start the treatment 7 For any emergency situation please press the emergency button Red Mushroom to shut down the laser immediately 8 After treatment if you want to turn off the system you can use the key to shut it down directly And turn off the air switch at the back panel You can remove the VAC plug if necessary 6 Operation UPPER LIP a icms ARM FLUENCE I sis my UNDERARM j 4 A oe os stand by LEC 1 2 1 3 1 HR professional hair removal Choose HR mode you will go to interface 1 2 here skin type sexual treatment part can be set and then ok go to interface 1 3 Our smart system will give you recommended parameter If you want to
9. th skin And you can also use the edge of the Aluminum 10 head of the handle piece to cool down the skin during treatment 11 Never shot the laser pulses to eyes or watch the laser directly 8 Maintenance 1 For DI water please check the degree of ions every month to make sure deionized 2 10 us cm 2 The machine must be operated in a room with air conditioner The room temperature is better lt 28 C 3 The environment temperature can not go below ZERO or the ice may damage the water tanks and water channels inside the machine and the handle piece 4 Clear the gel on the handle piece and make sure there is no dust around the Sapphire 5 Do not bend the tube of the handle piece too hard or this may cause water flow rate low warning 6 Do not plug in amp out the handle piece connectors frequently This may cause water leakage or water jam or bad electrical connections 7 Do not shot the laser at random targets or it may cause burning or fire 8 Always keep the handle piece with the holder on the main machine when you don t use it Otherwise the condensing water may flow back to the laser stack in handle piece so that cause laser failed 8 Warranty Notice Please take necessary protections for the operation of the machine and handle piece and notice that following situations can not be warranted 1 Operation the system without water 10 808nm Diode Laser Hair Removal Machine 2 Power up the system without connecting
10. the handle piece 3 Regular drops of the handle piece 4 Wrong input VAC 5 Other manual operating mistakes 9 Exception Handles After starting the hair removal machine by key switch the system will enter self check program if some parts of machine has problem there will be a warning show in the Status column on the screen and warning sound can be heard at the same time 1 Status Water temperature high The cooling water temperature range should be between 15 28 C If it higher than 30 C the laser will stop Please wait till water temperature going down The warning will disappear and system can be set again 2 Status Water flow rate low It means the cooling water flow rate lower than minimum requirement If the water flow rate which show at the bottom of the screen is just low not O L min Please first check along the water tube to confirm whether there are any jam in it and handle piece water connector are well locked Secondly open the water inlet at the back of machine to make the air pressure balance between the inside and outside of water circle system If the water flow rate show O L min Please first check whether the water pump are working Secondly take down the water flow sensor to check whether there are jam in it Or contact our company to ask for help 3 Status Filter and deionized water need change It means the conductivity of cooling water is higher than 20us cm Just wait for a minute till to w
11. usly come down Then warning will disappeared If the conductivity don t go down for long time please ask professional technician to change the ion exchange filter inside the machine G Status Operation wrong Press switch on the handle piece without enter ready status set the parameters fluence Frequency Cooling and press READY button to enable the handle piece For the typical treatment parameters you can refer to the recommended default or experienced doctor s advice During Ready status you also can adjust the skin cooling depending on skin feeling You may need to wait for several minutes before the skin cooling tip becomes cold Take the handle piece Pressure the pedal switch or the switch on the handle piece to shot the laser pulses Keep pressing the button and the laser output will continue Do not press amp release for single pulse You can stop the machine anytime by turn off the key in the front panel or press emergency 808nm Diode Laser Hair Removal Machine button Please follow those parameter during operating the machine Model No 808S Handle Piece Flow Rate 2L min 10 Cooling water temperature 23 28 C Working Environment Temperature 15 25 2 FHR fast hair removal Fast Hair Removal SUBTOTAL J EE FLUENCE 10J cm 10Hz WATER TEMP SE FLOW RATE L min TOTAL x1000shots If you choose FHR mode on interface 2 you will go to this interface with 5 treatment parameters
12. you just need to choose any parameter and then ready for treatment 3 SR skin rejuvenation WATER TEMP se FLOW RATE L min TOTAL x1000shots 808nm red light can make skin rejuvenation Choose SR you will go to this interface There are three levels for your choice soft comfortable and effective 808nm Diode Laser Hair Removal Machine 7 Treatment Notice 1 The treatment of the hair removal needs experienced professionals Do not use it if you have no experience for such kind of laser device 2 Operators and patients must wear laser goggles to protect eyes from any laser damage threat 3 Please notice that this is a high power laser device and if the patients feel very painful please stop the laser and check if there is anything happens to the patients skin Adjust it as a proper power that the patients can stand to do the treatment 4 Skin color is very important For white to light color you can adjust the Fluence can be adjusted to 40 90J cm2 Also you need to extend the treatment time for the dark skin to inject enough energy to the skin and follicles 5 The skin must be shaved before treatment 6 The handle piece is better to be operated at SCANNING mode It is faster for treatment 7 Skin contact gel is no necessary for treatment It won t make the treatment better or improve the skin feeling 8 You need to wait for several minutes before the cooling tip becomes cold 9 Keep contact the cooled Sapphire wi