1. Wiring passage Unless otherwise specified all measurements are expressed in millimetres mm The REX automation wall fixing measurements are illustrated in the diagram considering that the door wing profiles are not of our production If the door wings are made with DITEC profiles of the following series PAM16 PAM23 PAM45 refer to the measurements in the related manuals Fix the box with M 212 steel plugs or 6MA screws Distribute the fixing points approx every 800 mm Make sure that the box is level and its top surface is perpendicular with the floor and not deformed lengthwise with the shape of the wall If the wall is not straight and smooth the box must be fixed to metal plates WARNING The fastening of the box to the wall must be suitable in order to sustain the weight of the door wings REXAIC AC1356 REXAC AC1356 061 100 q gt 70 LD TIT Vo 25 fie o oe OOS o om ero hh S Pre a a Py gt i Ol p aj DE 091 Wiring passage L6760 6106 NISELCd IP2135EN 2013 09 27 9 2 Preparation of the glass door wing The diagram indicates the process measurements of the aluminium profile AC1356 and glass 210 through holes are required on the aluminium profile and 8
2. All installation maintenance and repair work must be documented and made available to the user Forthe correctdisposalofelectricand electronicequipment waste batteries and accumu X lators the user must take such products to the designated municipal collection facilities Technical data Ditec REX S Power supply 230 V 50 60 Hz Power fuse FIA Rated power input 200 W Service life o VERY INTENSE Temperature 2005350 Degree of protection IP20 FOR INTERNAL USE ONLY Control panel EL20 Accessories power supply 24 V 0 5 A The following safety devices may be installed to protect the danger areas according to EN 16005 PAS024AMW microwave infraredJ or Combined sensor for opening and safety during closing 1 PASAA2 infrared only external side o PASO24AMW microwave infrared or Combined sensor for opening and safety during closing PASAA2 infrared only internal side operator 3 PASATA Safety during opening sensor outside or inside the opera tor s housing Entrematic Group AB Lodjursgatan 10 SE 261 44 Landskrona Sweden www ditecentrematic com DETACH AND DELIVER TO THE CUSTOMER IP2135EN 2013 09 27 K Manual release instructions DETACH AND DELIVER TO THE CUSTOMER IP2135EN 2013 09 27 d In the event of maintenance malfunctioning or emergency lower the lock release lever LOKSBM if installed and move the door wings manually into the open position To block the door wings again reposit
3. 15 on the glass for fastening The number of holes and related distance between centres are based on the door wing width Silicon should ideally be used between the edge of the glass and the internal base of the profile e o i i 100 100 i 100 100 100 100 L 1000 L gt 1000 L 1000 i L gt 1000 3 POE ol mi p Ls 1000 _ Zl 9 3 Wings installation and adjustment al the wheels rest on the guide Fix the door wing to the carriage with screws a The outer wheel of the carriage must not protrude beyond the dimension of the door wing Adjust the horizontal position of the door wing in accordance with the measurements Indicated in diagram REX 2 for 2 door wing automations REX 1 RH for right hand opening automations and REX 1 LH for left hand opening automations Secure the adjustment with screws al Loosen screws b adjust the vertical position of the door wing by means of screw c and fix the adjustment with screws b Check by moving the door manually that the movement is free and without friction and that WARNING Leave a gap of at least 10 mm between the glass door wings when closed to avoid contact of the glass 2 WINGS 1 WING LEFT OPENING IP2135EN 2013 09 27 IP2135EN 2013 09 27 9 4 Floor guide installation The floor guides must be made of an antifriction material such as PVC NYLON TEFLON
4. D tec ENTREMATIC T Ei Tae a er a zai p Ditec REXS IP2135 EN Technical manual www ditecentrematic com Index Subject Page 1 General safety precautions 3 2 Declaration of incorporation of partly completed machinery 4 2 Machinery directive 4 3 Technical data 5 Gal Applications 5 Standard installation 6 5 Installation of the automation 7 TAJ Box fastening 7 DA Preparation of glass door wing 9 5 3 Door wing installation and adjustment 10 94 Floor guide installation 11 o Belt adjustment 12 5 6 Lock installation 12 Electrical connections 13 Ordinary maintenance program 14 User instructions 15 General safety precautions 15 Manual release instruction 17 Function selector user instructions 18 Key A teme semon aona sa oen eate i This symbol indicates useful information for the correct functioning of the product IP2135EN 2013 09 27 IP2135EN 2013 09 27 1 General safety precautions Failure to observe the information in this manual may result in minor personal injury or damage to equipment Save these instructions for future reference This installation manual is intended for qualified personnel only Installation electrical connections and adjustments must be performed in accordance with Good Working Methods and in compliance with the present standards Read the instructions carefully before installing the product Bad installation could be dangerous fW The packaging m
5. Group AB Lodjursgatan 10 SE 261 44 Landskrona A itec www ditecentrematic com ENTREMATIC CE
6. The length of the floor guide should not be greater than the overlap of between the fixed and mobile door wing and must not enter the doorway The measurements of the code 0KP515AB floor guide for framed door wings are indicated in the diagram D i a X vs 4 j qd min 21 max 40 diagram o o Belt adjustment Loosen screws a and tighten screw b until maximum extension of the spring Loosen the screws that attach the return unit to the guide Manually pull the entire return unit to the left and attach it to the guide Loosen screw b until the spring is at a compression of 20 mm lif the length of the automation is lower than 2600 mm or 22 mm lif the length of the automation is greater than 2600 mm Block the adjustment by tightening screws a WARNING incorrect adjustment impairs the correct functioning of the automation 5 6 Lock device installation Place the door wing in the closure position Fasten the lock device to the box profile by means of the supplied screws a Align the lock pin b and the lock bracket c and manually check the correct functioning Slightly lubricate the lock pin and lock bracket For further information refer to the blocking device Installation manuals A r i 5 a NZ IP2135EN 2013 09 27 IP2135EN 2013 09 27 Electrical connections Electrical wiring and star
7. agnetic Compatibility Directive 2004 108 EC technical documentation conforms to Annex VII B to the Directive 2006 42 EC technical documentation is managed by Marco Pietro Zini with offices in Via Mons Banfi 3 21042 Caronno Pertusella VA ITALY a copy of technical documentation will be provided to national competent authorities following a suitably justified request Landskrona 05 03 2013 Marco Pietro Zini x Tao IPresidgrt 2 1 Machinery Directive Pursuant to Machinery Directive 2006 42 EC the installer who motorizes a door or gate has the same obligations as the manufacturer of machinery and as such must prepare the technical file which must contain the documents indicated in Annex V of the Machinery Directive The technical file must be kept and placed at the disposal of competent national authori ties for at least ten years from the date of manufacture of the motorized door draw up the EC Declaration of Conformity in accordance with Annex II A of the Machinery Directive and deliver it to the customer affix the EC marking on the motorized door in accordance with point 1 7 3 of Annex of the Machinery Directive IP2135EN 2013 09 27 IP2135EN 2013 09 27 3 Technical data Ditec REXS Power supply 230 V 50 60 Hz Absorption 0 5 A Power fuse F1A Rated power input 200 W Max speed 1 wing 0 6 m s Max speed 2 wings 1 2 m s Service life 5 HEAVY DUTY Intermittence S3 100 Max door weight 1 win
8. apted accordingly for ensuring maximum durability and trouble free operation 4 Standard installation Ref FEO NN 10 11 12 Code Ditec REX S EL20 AL15 REXAB PAS024AMW microwave infrared or PASAA2 only infrared PASO24AMW microwave infrared or PASAA2 only infrared PASAT3 LOKSBM COME COMHK CELPR MD1 MDA PFP1 PFP2 PDP1 PDP2 Description Operator Drive unit Control panel Transformer Emergency batteries optional No break batteries optional Combined sensor for opening and safety during closing external side Combined sensor for opening and safety during closing internal side operator Safety during opening sensor outside or inside the ope rator s housing Release handle Functions selector switch Photocells NOT ACCORDING TO STANDARD EN 16005 Display Open push buttons Connect the power supply to an approved omnipolar switch with an opening distance of the contacts of at least 3mm not supplied The connection to the mains must be made via an independent chan nel separated from the connections to command and safety devices IP2135EN 2013 09 27 IP2135EN 2013 09 27 5 Installation of the automation 5 1 Box fastening Lo mm L a en m REXAIC REXAL P833 __A_Y 2995 on u am H 28 H HM
9. aterials plastic polystyrene etc should not be discarded in the environ ment or left within reach of children as these are a potential source of danger Before installing the product make sure it is in perfect condition Do not install the product in explosive areas and atmospheres the presence of inflammable gas or fumes represents a serious safety hazard Before installing the motorisation device make all the necessary structural modifications in order to create safety clearance and to guard or isolate all the crushing shearing trapping and general hazardous areas Make sure the existing structure Is up to standard in terms of strength and stability The motorisation device manufacturer is not responsible for failure to observe Good Working Methods when building the frames to be motorised or for any deformation during use The safety devices photocells safety edges emergency stops etc must be installed taking into account applicable laws and directives Good Working Methods installation premises system operating logic and the forces developed by the motorised door The safety devices must protect the crushing cutting trapping and general hazardous areas of the motorised door Display the signs required by law to identify hazardous areas Each installation must bear a visible indication of the data identifying the motorised door When requested connect the motorised door to an effective earthing system that complies with current
10. f the automation Without 230 V power supply and batteries Clean and lubricate the moving parts the carriage guides and the floor guides Check the belt tension Clean sensors and photocells Check the stability of the automatic system and make sure that all screws are correctly tight ened Check the alignment of the doors the closing positions and the correct introduction of the blocking device Connect the 230 V power supply and batteries Check that the blocking system is working correctly Check the stability of the door and that the movement is regular and without friction Check that all command functions are operating correctly Check the correct functioning of the photocells Check that the doors developed powers are In accordance with applicable regulations IP2135EN 2013 09 27 X Ditec REX S Ditec DETACH AND DELIVERTO THE CUSTOMER IP2135EN 2013 09 27 user s manual ENTREMATIC General safety precautions The following precautions are an integral and essential part of the product and must be sup plied to the user Read them carefully since they contain important information on safe installation use and malntenance These instructions must be kept and forwarded to all possible future users of the system This product must only be used for the specific purpose for which it was designed Any other use is to be considered improper and therefore dangerous The manufacturer cannot be held respon
11. g 100 kg Max door weight 2 wings 140 kg Temperature 2096 55 C Temperature with batteries 10 C 50 C Degree of protection IP20 FOR INTERNAL USE ONLY Control panel EL20 Accessories power supply 24 Ve 0 5 A 31 Operating instructions Service class 5 minimum 5 years of working life with 600 cycles per day Applications VERY INTENSE for shared entrances with very intense pedestrian use Performance characteristics are to be understood as referring to the recommended weight approx 2 3 of maximum permissible weight A reduction in performance is to be expected when the access is made to operate at the maximum permissible weight Service class running times and the number of consecutive cycles are to be taken as merely indicative having been statistically determined under average operating conditions and are therefore not necessarily applicable to specific conditions of use During given time spans product performance characteristics will be such as not to require any special maintenance The actual performance characteristics of each automatic access may be affected by independ ent variables such as friction balancing and environmental factors all of which may substan tially alter the performance characteristics of the automatic access or curtail its working life or parts thereof including the automatic devices themselves When setting up specific local conditions must be duly borne in mind and the installation ad
12. ion the lock release lever to the initial position AN WARNING carry out the door wing blocking and release with the motor switched off Entrematic Group AB Lodjursgatan 10 SE 261 44 Landskrona Sweden www ditecentrematic com User instructions function selector The STOP position prevents the batteries from engaging In case of emergency NOTE for correct door operation and regular battery recharging itis essential that the automatic system be always powered with batteries connected also during the night FUNCTION SELECTOR DOOR OPEN The door opens and remains open TOTAL ONE WAY OPENING For one way operation from the inside outside of the door TOTAL TWO WAY OPENING For two way door operation PARTIAL OPENING For two way one way and partial opening operation PARTIAL OPENING For two way partial opening DOOR CLOSED The door closes and remains closed and locked if lock is present IMMEDIATE NIGHT TIME CLOSURE STOP The door stops immediately when the NIGHT TIME CLOSURE key is pressed for 3 s DELAYED NIGHT TIME CLOSURE Pressing the NIGHT TIME CLOSURE key the door closes after 10 seconds with J1 ON or 60 seconds with J1 OFF This allows authorised door management personnel to get out before it closes IMMEDIATE NIGHT TIME CLOSURE The door stops immediately when the NIGHT TIME CLOSURE is selected POWER RESET Cancels the data acquired proceeding with a new acquisition after 3 seconds DMCS Jac
13. k This is used to connect the DMCS software N B The DMCS jack can be accessed by removing the function selector switch cover SETTING THE CODE with J3 ON The code can contain up to 5 numbers Press the LOCK key for 3 seconds Enter the numerical code NOTE the red LED flashes during this procedu re Press the LOCK key for 3 seconds If the LED remains steady on the selector is protected by an access code CANCELLING THE CODE with J3 ON Press the LOCK key for 3 seconds Enter the numerical code NOTE the red LED flashes during this procedu re Press the LOCK key for 3 seconds If the LED is switched off the selector is working and no access code is set COME el l e er fe or C E J C pajo DMCS jack COMH K DMCS jack DETACH AND DELIVER TO THE CUSTOMER IP2135EN 2013 09 27 DETACH AND DELIVER TO THE CUSTOMER IP2135EN 2013 09 27 All the rights concerning this material are the exclusive property of Entrematic Group AB Althoughthe contentsofthis publication have been drawn up withthe greatest care Entrematic Group AB cannot be held responsible in any way for any damage caused by mistakes or omissions in this publica tion We reserve the right to make changes without prior notice Copying scanning and changing in any way are expressly forbidden unless authorised in writing by Entrem atic Group AB IP2135EN 2013 09 27 Entrematic
14. safety standards During installation maintenance and repair operations cut off the power supply before opening the cover to access the electrical parts The automation protection casing must be removed by qualified personnel only The electronic parts must be handled using earthed antistatic conductive arms The manufacturer of the motorisation declines all responsibility in the event of component parts being fitted that are not compatible with the safe and correct operation Use original spare parts only for repairs or replacements of products The installer must supply all information on automatic manual and emergency operation of the motorised door and must provide the user with the operating Instructions 2 Declaration of incorporation of partly com pleted machinery Directive 2006 42 EC Annex II B The manufacturer Entrematic Group AB with headquarters in Lodjursgatan 10 SE 261 44 Landskrona Sweden declares that the automation system for Ditec VALOR sliding doors has been constructed to be installed on a manual door to construct a machine pursu ant to the Directive 2006 42 EC The manufacturer of the motorized door shall declare conformity pursuant to the Directive 2006 42 EC annex II A prior to the machine being put into service conforms to applicable essential safety requirements Indicated in annex chapter 1 of the Directive 2006 42 EC conforms to the Low Voltage Directive 2006 95 EC conforms to the Electrom
15. sible for any damage caused by improper incorrect or unreasonable use This product should not be used by people including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervi sion or instructions concerning the use of the appliance by a person responsible for their safety Avoid operating in the proximity of the hinges or moving mechanical parts Do not enter within the operating range of the motorized door while itis moving Do not block the movement of the motorized door since this may be dangerous Do not allow children to play or stay within the operating range of the motorized door Keep remote controls and or any other control devices out of the reach of children in order to avold possible involuntary activation of the motorized door In the event of fault or malfunctioning of the product turn off the power supply switch do not attempt to repair or intervene directly and contact only qualified personnel Failure to comply with the above may cause a dangerous situation All cleaning maintenance or repair work must be carried out by qualified personnel To ensure that the system works efficiently and correctly the manufacturer s Indications must be complied with and routine maintenance of the motorized door must be performed by quali fied personnel In particular regular checks are recommended in order to verify that the safety devices are operating correctly
16. ting are shown in the installation manual of control panel EL20 Make sure the yellow green conductor is at least 30 mm longer than the brown and blue conductors Before connecting the power supply make sure the plate data correspond to that of the A mains power supply An omnipolar disconnection switch with minimum contact gaps of 3 mm must be included in the mains supply Check that upstream of the electrical installation there is an adequate residual current circuit breaker and a suitable overcurrent cutout Use a HOSRN F 361 5 or HOSRR F 361 5 type electric cable and connect to the terminals L brown N blue yellow green in the automation Make sure the yellow green conductor is at least 30 mm longer than the brown and blue conductors Secure the cable using the special cable clamp and remove the outer sheath near the terminal only Connection to the mains power supply in the section outside the automation is made with independent channels and separated from the connections to the control and safety devices The channels must penetrate a few centimetres inside the automation thorough a hole maxi mum 216 mm Make sure there are no sharp edges that may damage the power supply cable Make sure that the mains power supply 230 V conductors and the accessory power supply 24 V conductors are separate Routine maintenance plan Perform the following operations and checks every months according to intensity of use o