PST-100HL - User manual
Contents
1. the rubber belt fig 2 Re assemble the device Fig 2 Rubber belt replacement Warranty and Claims The Manufacturer guarantees the compliance of the unit with the requirements of Specifications provided the Customer follows the operation storage and transportation instructions The warranted service life of the unit from the date of its delivery to the Customer is 24 months Contact to your local distributor to check availability of extended warranty Ifany manufacturing defects are discovered by the Customer an unsatisfactory equipment claim shall be compiled certified and sent to the local distributor address Please visit www biosan lv Technical support section to obtain the claim form The following information will be required in the event that warranty or post warranty service comes necessary Complete and retain for your records Model PST 100HL Plate Shaker Thermostat Serial number Date of sale Page 10 8 Declaration of Conformity Declaration of Conformity Equipment name PST 100HL Type of equipment Plate Shaker Thermostat Directive EMC Directive 2004 108 EC Low Voltage Directive 2006 95 EC RoHS 2011 65 EC WEEE 2002 96 EC amp 2012 19 EU Manufacturer SIA BIOSAN Ratsupites 7 build 2 Riga LV 1067 Latvia Applied Standards EN 61326 1 Electrical equipment for measurement control and laboratory use EMC requirements General requirements EN 61010 1 Safety requ
2. 1 3 set the necessary temperature increment 0 1 C Pressing the key for more than 3 s will increase the increment Caution The planform heating can be turned off only by setting the required temperature below 25 C the display will show OFF T C Set It can be used in cold rooms as a mixing device without thermal regulation in this mode Program execution After the thermal stabilisation of the unit when the set and current temperature readings become the same Place microplates on the platform and fix it with the special holder by pressing it against the plate covers 1 2 3 4 Set 00 00 1000 37 0 Actual STOP 000 37 0 hrimin RPM TCO P O P E Thermo Sha ker TIME RPM T C RUN STOP Fig 1 Control panel Page 7 4 4 2 4 4 3 A 4 5 4 6 4 7 4 8 4 9 Page 8 Correct loading Caution The microplate fixation screw must always be tightened to avoid damage Tighten the fixation screw completely when microplates are removed from or placed on the platform Do not close the lid if the microplate fixation screw is not tightened to avoid damage Caution Load only pairs of microplates for best fixing Wrong loading Press the RPM RUN STOP key Fig 1 4 The platform will start rotating and the timer indicator will start counting up the time interval with 1 min precision After finishing the program the platform motion will st
3. D Medical Biological Research amp Technologies PST 100HL Plate Shaker Thermostat PST 100HL Operating Manual for version Certificate V 1AW Contents Safety Precautions General Information Getting Started Operation Specifications Maintenance Warranty and Claims o NoNaNo Declaration of Conformity Page 2 1 Safety precautions The following symbols mean A Caution Make sure you have fully read and understood the present Manual before using the equipment Please pay special attention to sections marked by this symbol AN Caution Hot surface Platform surface becomes very hot during use Always use protective cotton gloves to install or remove microtest plates and to fix or release fixation holder when set temperature is higher than 60 C GENERAL SAFETY Use only as specified in the Operating Manual provided The unit should be saved from shocks or falling The unit must be stored and transported in a horizontal position see package label After transportation or storage keep the unit under room temperature for 2 3hrs before connecting it to the electric circuit Use only cleaning and decontamination methods recommended by the manufacturer Do not make modifications to the design of the unit ELECTRICAL SAFETY Connect only to the external power supply unit with voltage corresponding to that on the serial number label Use only the external power supply unit provided with this pr
4. cubation of micro quantities insect plant cell cultures etc in plates 2 microplate Shaker for operation in the cold room or other conditions which do not require temperature stabilization 3 microplate Thermo Shaker for immunochemistry and molecular diagnostics where the requirements to the result reproducibility and thus to the precise method regulation are particularly high A distinctive feature of BioSan plate thermal shakers is the patented two side plate heating that allows to achieve full correspondence of the set and actual temperature in the plate wells Thermo Shaker PST 100HL provides softorintensive sample shaking rotation speed regulation stabilization and indication even shaking amplitude throughout Shaker Thermostat platform required operation time setting and indication automatic stopping of the platform movement after the set time expires current operation time indication setting and indication of the required temperature The device can be used in cytochemistry for in situ reactions immunochemistry for immunofermentative reactions biochemistry for enzyme and protein analysis molecular biology for matrix analysis DNA and RNA analyses The maximum guaranteed number of diagnostic cycles in the Thermo Shaker mode which require 15 30 min work in one cycle is 7000 14000 times External 12V power supply unit is used to power the device It makes it safe to work in the cold roo
5. eeeeseeaeeeeeeseaeeeeeetes 2 Platform dimensions sissies dieea tani Adana 250 x 150 mm DIMENSIONS 20 208 eh ee ti Sid te eine 270x260x125 mm Input current power CONSUMPTION eect eeeteeeeeeeeeeeees 12V 5A 60W External power supply input AC 100 240 V 50 60Hz output DC 12 V WIGNT sii icin ahead Getafe cient ad tiie 5 9 kg Accurate within 10 Replacement parts Description Catalogue number Rubber belt 122 x6x0 6 mm BS 000000 S18 Company retains the right to make changes and supplements in product design aimed at enhancement of consumer performance and operation quality without prior notice Page 9 6 1 6 2 6 3 6 4 7 1 7 2 7 3 7 4 Maintenance If the unit requires maintenance disconnect the unit from the electric circuit and contact Biosan or your local Biosan representative All maintenance and repair operations must be performed only by qualified and specially trained personnel Standard ethanol 75 or other cleaning agents recommended for cleaning of laboratory equipment can be used for cleaning and decontamination of the unit Rubber belt replacement For maintenance of reliable operation of the device the producer recommends to replace rubber belts after 1 5 years or 2000 hours of operation time Disconnect the external power supply unit from the device Remove 4 fixation screws on the divece bottom and remove the bottom plate Replace
6. irements for electrical equipment for measurement control and laboratory use General requirements EN 61010 2 010 Particular requirements for laboratory equipment for the heating of materials EN 61010 2 051 Particular requirements for laboratory equipment for mixing and stirring this product conforms to the requirements of the above Directive s Signature Signature Svetlana Bankovska Aleksandr Shevchik Managing director Engineer of R amp D 12 00 201 42 06 204 Date Date Version 1 03 December 2014 How to choose a proper Shaker Rocker Vortex ES 20 60 with heating Applications Microbiology ans Extraction s Cell growing PSU 10i we amp Volume of liquids 10 10 ml Erlenmeyer flasks Cultivation flasks and 50 ml tubes E tate AA SS ee A a Multi Bio RS 24 Applications Multi RS 60 Microbiology Extraction Cell growing J J 1 e x gt a PE V 1 gJ i Applications SSS MR 1 mam Applications T Agglutination gg l Com Extraction i Gel staining m destaining Multi Bio 3D Applications Agglutination Extraction Blot hybridisation Gel staining destaining Sse 88 3 10 ml Petri dishes vacutainers and tubes up to 15 ml DNA analysis Medical Biological Research amp Technologies Genome sequence CHB O gt PST 60HL p PST 100HL
7. m where condensation may cause leakage current from electric circuit PST 100HL innovation is appliance of the newest gradient two cascade peripherical heating of the platform for two 96 well plates technology During the Shaker Thermostat with heating up to 100 C designing Biosan successfully solved the problem of high temperature uniformity throughout the whole platform surface in stable mixing conditions up to 1200 rpm Page 5 3 1 3 2 Page 6 Getting started Unpacking Remove packing materials carefully and retain them for future shipment or storage of the unit Examine the unit carefully for any damage incurred during transit The warranty does not cover in transit damage Complete set Package contents PST 100 HL Plate Shaker Thermostat cccceeceeeeseeeeeeeeeeeeeeeeees 1 piece Spare rubber belt cessive Anan iatiinen decid Balad 2 pieces external power SUPPIY UNIt 2 0 2 2 eee ceee cee ceeeeee cece eeeeeneaeeeeeeseeaeeeeeeeeeeeeeeeees 1 piece POWCP CONG EE E AEE EA bdacited adda stiiel hdasaiaess 1 piece Operating Manual Certificate 0 0 ninin a 1 copy Setup place the unit upon even horizontal non flammable surface away from any flammable materials not less than 30 cm remove protective film from the display plug the external power supply unit into the socket at the rear side of the unit and position the unit so that there is easy access to the power switch and the external power supply u
8. nt 4 Operation Recommendations during operation A 4 1 4 2 4 3 4 3 1 4 3 2 4 3 3 4 4 4 4 1 Please check the plates before using Don t heat the plates over the melting point of the material they are made of Caution Surfaces of the platform become very hot during the use over 60 C To place or remove the microplate use the protective cotton gloves Connect the external power supply unit to a grounded power socket and set the power switch located on the rear panel of the unit to position ON The display will turn on with the upper line Set showing time speed and temperature set earlier and the lower line Actual showing current readings of the same parameters thermoblock temperature C which automatically starts rising according to the temperature set in the upper line The time of temperature stabilisation depends on the initial temperature Setting the parameters Use the readings in the upper line of the display Set while setting the required parameters Setting time TIME Using the A and W keys Fig 1 1 set the required working time interval in hours and minutes increment 1 min Pressing the key for more than 3 s will increase the increment Setting speed RPM Using the A and W keys Fig 1 2 set the required shaking speed increment 10 RPM Pressing the key for more than 3 s will increase the increment Setting temperature T C Using the A and W keys Fig
9. oduct Ensure that the switch and external power supply unit are easily accessible during use Do not plug the unit into an ungrounded power socket and do not use an ungrounded extension lead Disconnect the unit from electric circuit before moving Disconnect the external power supply unit from power socket to turn off the unit If liquid penetrates into the unit disconnect it from the external power supply unit and have it checked by a repair and maintenance technician Do not operate the unit in premises where condensation can form Operating conditions of the unit are defined in the Specifications section Page 3 DURING OPERATION Do not leave the operating unit unattended Do not impede the platform motion Do not operate the unit in environments with aggressive or explosive chemical mixtures Do not operate the unit if it is faulty or has been installed incorrectly Do not use outside laboratory rooms Do not check the temperature by touch Use a thermometer BIOLOGICAL SAFETY Page 4 It is the user s responsibility to carry out appropriate decontamination if hazardous material is spilt on or penetrates into the equipment 2 General Information PST 100HL Plate Shaker Thermostat is designed for shaking 2 standard 96 well microplates in the thermostating mode Plate Shaker Thermostat was designed using the multi system principle which allows using it as three independent devices 1 incubator for lasting in
10. op and the timer will be showing the flashing reading STOP accompanied by the repetitive sound signal until the RPM RUN STOP key is pressed Caution At the end of the set time period the platform movement is stopped automatically but the heating has to be stopped by reducing the temperature using the W T C key Fig 1 3 lower key tillthe OFF sign appears in the upper part of the display If the working time is not set or is reset and the timer indicator in the upper line shows 00 00 pressing the RPM RUN STOP key will start continuous operation of the Thermo shaker timer indicator will start counting up the time interval in the lower line Actual until the RPM RUN STOP key is pressed again Note The platform temperature will be constantly maintained in accordance with the set temperature This allows using the device again without pre heating The timer can be reset during operation if required Press the TIME RUN STOP key once Fig 1 5 to stop the timer Press the TIME RUN STOP key again to restart the timer The platform motion can be stopped at any time by pressing the RPM RUN ISTOP key In this case the program realisation and the platform motion will stop and the timer will switch into the STOP mode saving previously set time Press the RPM RUN STOP key to repeat the operation with the same time and speed When lid is open the platform and lid heating surfaces will remain hot Please take necessary care and use protecti
11. sel with heating PST 60HL 4 with heating or A Applications ELISA analysis PSU 2T Hybridization MPS 3500 w E lt TS 100 with heating TS 100C with heating and cooling 10 10 ml PCR plates microtest plates and Eppendorf type tubes www biosan lv Biosan Sia Ratsupites 7 build 2 Riga LV 1067 Latvia Phone 371 674 261 37 Fax 371 674 281 01 E mail marketing biosan lv
12. ve cloth gloves at temperatures over 60 C After finishing the operation set the power switch located on the rear panel of the unit in position O Off and disconnect the external power supply from electric circuit 5 Specifications The unit is designed for operation in cold rooms incubators and closed laboratory rooms at ambient temperature from 4 C to 40 C in a non condensing atmosphere and maximum relative humidity 80 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 40 C 5 1 Temperature specifications SOT GANGS TEE TAEA EAE A EAE 25 C 100 C Coontrol Tange ice ai eee tonite den ceteaaien 5 C above RT to 100 C Setting PESOMMON ipsis a aa ia neces 0 1 C Stability from 25 C to 60 C occ nen a N E 0 1 C Uniformity over the platform at 37 C occ eens eeeeeeeteeeeeenteeeeeeeees 0 2 C Time of thermoblock heating from 25 C till 100 C 0 0 eee 60 min General specifications Speed reg latiOm ssri ies taadsinetad ie ena pees 250 1200 rpm Speed setting resolution ccccccceeccceceeeeeeceeeeeeeeeeeeeeaeeeseeeenaeeeeeeee 10 rpm OMI sgh eresse ee A ie IA NE 2mm Timer with Sound signal i e 1 min 96 hrs non stop TIME Setting FESOILON psorosis 1 min DISPlay EA E E E Renee aa ea 16x2 signs LCD Max height of microwell plates cccccccceececeeceeeceeeeeeeeeeeeessaeeeeees 18 mm Number of microwell plates cccccccceeeeeeeece cee eeceeeee