Home

JA-65 - Maestro Hybrid control panel

image

Contents

1. To stop alarm Panic alarm enter your access code or press the A button on the remote control System will beep and will start exit delay count down You must leave the protected area during the exit delay enter your access code or press the B button on the remote control The panel will beep twice and will disarm When you enter the protected area before disarming the entrance delay count down will start If disarming is confirmed with three beeps check the keypad indicators for information alarm memory failure low battery etc enter your access code or press the B button on the remote control pressing or entering F 7 before your code will trigger a silent panic alarm This can also be triggered by the RC 22 panic button or by pressing and holding of both buttons of the RC 11 remote control for 3 seconds User instructions of JA 65 Maestro 1 6 MFM51308 Optional user functions following functions can be enabled or disabled in the programming mode AJ arming without a code disarming is only possible with an access code entry of F1 can be used on JA 60D keypad for this function If the system is split then this button can be used for arming of section A Ai partial home arming detectors addressed to B section will be ignored except Smoke amp Gas detectors On the JA 60D keypad code F2 can be used for partial arming If the system is split then this button can be used for arming of section B If the control p
2. hh hours from 00 to 23 mm minutes from 00 to 59 6 disarm _ _ disamB Notes e f any automatic action is selected it will be preformed everyday in the programmed time following the internal control panel clock see 12 27 e The automatic arming and disarming can be overridden manually anytime by an user code or a remote control e f the control panel is in the requested arming mode before the action time performance of the programmed action will not change the arming Example to program an automatic complete arming of the system at 21 15 everyday enter 640 1 21 15 Factory default setting all instructions are set for no action 9 Battery replacement in the wireless items All the battery powered items perform regular battery testing If the life time of the battery is near the end the system will indicate the need for battery replacement low battery indicator and address of the particular item will be shown on the LED display When any detector or keypad asks for new batteries do following e switch the control panel to the user mode FO master code e open the cover of the detector keypad and replace its batteries with new ones use only corresponding size and good quality alkaline batteries Wait for apr 20 sec before inserting batteries e close the device s cover and test the device to confirm it is working e to exit User mode press the N key on the control panel Recommendations e the system shoul
3. Master Code factory default UC 1234 indicated by a U on the display This can only be done while the panel is disarmed e The parameters of the dialer can be set by entering programming sequences from the keypad Any unfinished programming sequence can be terminated by pressing the N key e To exit the user mode press the N key U will turn off User instructions of JA 65 Maestro 2 6 MFM51308 List of the voice amp Pager user programmable parameters Function sequence options noe O Telephone numbers for voice message numbers for voice message 7XX X TK Fy xx X tel number y memory 1 to 4 pause FO Ca ei dialing programming eee xF9z ZF5 x x provider tel number z Z pager number message Erase Erase telephone number number 7FOFy y memory 1 to 5 entering 7FOFO erases all 4 amp hold REC button at the X module if 2 messages see 14 2 Dialer testing E if 2 messages 88 amp 89 5 1 Telephone number entering sequence 7xxx xxFy Store telephone numbers for voice message entering 7 xx xx F y XX XX gt telephone number y gt memory number from 1 to 4 A telephone number can have a maximum of 16 digits A pause can be entered with FO pause can not be entered as the first digit Example to store tel number 02 123456 to memory no 2 enter 7 02 FO 123456 F2 Note enter a pause FO after the last digit of a number which is calling a mobile phone This way the number wil
4. User instructions of JA 65 Maestro 1 Indicators Alarm alarm triggered by an intruder smoke gas etc Tamper opened cover damaged detector excessive number of attempts to enter code etc Fault power loss lost communication with a detector etc confirm pressing key N Battery battery of the device specified on the display is low See battery replacement section a wireless communication in progress or information received from a wireless item Armed continues armed slow blinking exit delay fast blinking entrance delay Power continues AC power amp back up battery are O K blinking failure AC power or back up battery off control panel is not powered Two digits display Specifies event source or mode of the control panel event sources lto 16 zone input number when is lit simultaneously the event was triggered by a corresponding wireless detector cltocH wireless controller or keypad number is lit simultaneously C control panel A wireless siren d sub system other JA 60 or 65 system enrolled L telephone line d digital line PC interface keypad JA 60E F wireless communication of the keypad lost JA 60F only control panel modes P programming mode u user mode bypass setting testing battery replacement voice dialer setting H home partial arming inputs amp wireless detectors addressed to B section are bypassed l section A arming split system 1 section B arming split system Ca arming of
5. anel was not programmed for partial arming or was not split this button has no function J door opening will release electric door lock if connected to the system PgX or PgY outputs On the JA 60D keypad code F3 can be used for this function i panic alarm if you are under duress press this button before your code this will trigger a silent alarm if the system is armed it will also disarm On the JA 60D keypad code F7 can be used before your code to trigger a panic alarm F4 memory reading indicators and LED display will show where and what happened press key 4 multiple times to go deeper into the memory Complete events list including date amp time can be viewed using PC with Comlink SW F5 new Master Code after F 5 the current master code must be entered followed by the new one twice Example to change Master code from 1234 to 2738 enter F5 1234 2738 2738 F6 new User Code after F 6 the valid master code must be entered number of the new user code 01 to 14 and then the new user code To erase any User code completely set it to 0000 Example user code number 5 can be entered for combination 6789 while Master code is 2738 entering F 6 2738 05 6789 F9 voice message listening to check the message s of the telephone dialer control panel built in speaker will play all the recorded messages once FO user programming mode entering F 0 Master Code will be confirmed by U on the LED display The cont
6. d be annually inspected function testing condition of back up batteries working range of the items etc by a professional e after 5 years the control panel and the outdoor siren back up batteries should be replaced with new ones User instructions of JA 65 Maestro 4 6 MFM51308 10 Device control Devices like ventilation heating etc can be attached to the system during installation Then the device can be controled by the system ON OFF e By keypad device can be turn on by entering F 81 on keypad and turn off by enterting F 80 i not possible from JA 60D kepad e SMS message send a special controll SMS to GSM communicator which must be a part of the installation entering code may be ruquired set by installer when istalled System layout and basic settings 10 11 12 13 14 15 Exit Entrance delay Sec Alarm duration Minutes User instructions of JA 65 Maestro 5 6 MFM51308 Alarm system user list CO NO O01 Oo PO Telephone communicator numbers Telephone number 1 Telephone number 2 Telephone number 3 Telephone number 4 Pager number User instructions of JA 65 Maestro 6 6 MFM51308
7. ence 4 hh mm dd MM YY hh gt hours 24 hr cycle mm gt minutes dd gt day MM gt month YY gt year Example on Jun 30 2005 at 17 15 enter 4 17 15 30 06 05 7 Enrollment of the control panel to a UC 2xx or to a master control panel The control panel can send wireless data to output modules UC 216 UC 222 and UC 260 It can also work as a subsystem of another JA 65 or JA 60 control panel Enter the enrolling mode of the UC receiving device and then enter 299 and the control panel will generate the enrollment signal If you want to enroll a subsystem to your control panel enter the enrolling mode on the MASTER control panel see 12 1 and then enter sequence 299 in the programming mode of the sub control panel If the system is split the sub control panel enrolls to the common shared section 8 Automatic arming disarming setting The control panel can automatically arm and disarm for a requested period of a day Up to ten instructions time amp action can be programmed in the period of one day Open the User mode of the control panel by the sequence FO master code The User mode is actions table notified by the letter U on the display a no splitting split system To set the action use the sequence 64 nahhmm where 0 noaction noaction arm all arm all disarm all 3 n instruction number from 0 to 9 a action see the actions table partial arming arm A
8. l be called only once and the dialer will not check the line signals some mobile phone systems do not generate standard telephone line signals When activated the dialer will disengage all other devices hooked up to the phone line telephone fax It will then one by one call and play the user recorded message for all programmed numbers If the dialer makes a successful connection to a programmed number it will not call that number again If the number is busy the dialer will make 3 more attempts to call it Empty tel number memories are skipped If all memories are empty the dialer is completely disabled To delete a telephone number enter 7 FO Fy y gt is amemory number from 1 to 4 entering 7 FO FO will erase all tel numbers including the Pager number Store number to call Pager to memory number 5 entering 7 xx x F9 zzz zz F5 XX X gt provider prefix F9 gt separator it will wait for a provider s signal and will switch to DTMF if not used ZZ ZZ gt pager number and numeric message and other specific codes language selectors end of message etc if requested by the Paging provider F5 gt to store the number to memory no 5 As a maximum 32 digits can be stored to memory number 5 Special characters can be entered with the following Fx codes FO gt pause F7 gt F8 gt Example enter 7 0611 F9 1 1234 555 F80 F5 if the provider prefix is 0611 the Pager number 1234 and the message 555 Number 1 af
9. n the keypad and then press and hold the push button on the 65X module pressed User instructions of JA 65 Maestro 3 6 MFM51308 Telephone dialer testing sequence 8 9 Enter 89 and the dialer will call the programmed numbers once You will hear the telephone line signals from the control panel built in speaker during the test if the dialer is triggered by an alarm in normal operation it will call silently Testing can be terminated with the N key If two different voice messages were recorded then use sequence 88 to test the sending of the first message and 89 to test the sending of the second message Note if you enter 89 in the user mode when there is an incoming call on the telephone line the dialer will answer the call This is the way to allow the installer to dial in to your system from his computer even if the dialer was programmed to the never answer mode during installation But even with this manual approval the installer must know the digital dialer access code 8 digits to be able to establish connection This access code must be programmed during the installation factory default setting is 00000000 6 Real time and date setting The control panel has a built in real time clock All events are stored to the event memory including the time of the event At first open the User mode by the sequence FO master code The User mode is notified by the letter U on the display The clock can be set by the sequ
10. rol panel is now in the user mode for bypass setting system testing battery replacement voice dialer programming if enabled by installer Entering F 0 Service Code is used by the installer to enter the programming mode N exit not completed function code memory reading user mode etc Note While in the programming mode you can select that functions i F4 and F9 can be used only when followed by a code Master or User Acoustic indications and other features of the system can also be customized in the programming mode Wireless keypad JA 60D can have its own master code and one user code Both JA 60D codes can be different than the control panel codes 4 Zone bypassing By using the master code zone inputs and wireless detectors can be bypassed within a selected area of the house Bypass setting 1 open User mode entering F 0 Master Code will be confirmed by U on the LED display press 1 to enter the bypass menu keys 1 or 7 scroll all hard wire zone inputs and all wireless differed with indicator detectors select the input zone or wireless detector to be bypassed press key 2 and hold it for two seconds to set one arming period bypass of the selected zone battery indicator will start flashing to confirm the bypass If you press 2 again this bypass will be switched off etc on off on similar way with key 3 for a permanent bypass of the zone confirmed with continuous lighting of the battery indicator If you pre
11. ss 3 again this bypass will be switched off etc on off on 6 repeating the steps 3 5 you can set up and check requested bypasses 7 to cancel all selected bypasses press and hold key 4 while in the bypass menu 8 to exit the bypass menu press N to exit user mode press N again On w Arming of the system while a zone is bypassed is confirmed with four beeps and b will be indicated on the keypad during the exit delay period Notes Be sure to cancel a permanent bypass after there is no need for the bypass If one arming period bypass was selected for a zone this bypass is automatically canceled after the system is armed and then disarmed This remains valid for arming and disarming even if the system is split into two sections e All bypasses will be canceled after a factory default reset or after the main board s power is disconnected Information about arming and bypassing is stored in system s memory as a partial arming The bypass menu is only available in the user mode 5 Voice dialer programming by user If the control panel is equipped with a 65X telephone dialer module and if enabled in the programming mode during installation setting of the voice and Pager dialer telephone numbers and messages can be changed in the user mode with master code Setting can be performed by entering programming sequences from the keypad JA 60E or JA 60F while in the control panel user mode e Enter the user mode entering F 0
12. ter F9 is a language selector code F80 represents 0 end of message Note some Paging providers also offer an option to send the message as an SMS to the GSM network Consult your Paging provider for details if you have trouble sending a message to the Pager To delete the Pager number enter 7 F0 F5 If the memory number 5 is empty no message will be sent to a Pager 5 2 Voice message recording sequence 8 4 The existing message can be played by momentarily pressing the push button on the 65X module The control panel must be in the user mode before opening the control panel case To record your voice message enter 84 on the keypad and then press and hold the push button on the 65X module while talking into the 65X microphone max 20 seconds After releasing the button the message will play back The message is stored in non volatile memory and can be changed when ever you want to by repeating the above steps Make the message clear and brief The dialer repeats the message to each called number for 40 seconds It is possible to split the voice message into two different messages 10 seconds each Depending on the setting in the programming mode a particular message will be sent under different situations If your system uses two messages max 10 seconds each record them by entering 85 on the keypad and then pressing and holding the push button on the 65X module recording the first message To record the second message enter 86 o
13. the complete system 5 a zone is bypassed when arming waiting for more data to complete entry 2 Access codes The control panel can be operated with the following codes by JA 60E or JA 60F keypad or via connected PC Master code User codes Service code is an extra user code which can be used for arming disarming but also for code changes entering of user mode bypass setting system testing battery replacement voice dialer programming if enabled by installer factory default Master code is 1234 If the system is split the use of MC will arm all sections if no section is armed or it will disarm all sections if any is armed If no code arming is disabled and the system is spilt then entering F1 MC will effect only section A and entering F2 MC will effect only section B up to 14 different user codes can be set in the system for different users for arming and disarming only all are blank from the factory This way it is possible to differ between different users operations details about used codes are stored in the control panel internal events memory the Comlink software or the monitoring station can access these details is a code for installer to open programming mode for the control panel setting and testing entering F 0 Service code Note After 5 attempts to enter an invalid code a tamper alarm is triggered indicated by LED Tamper and C on the display 3 Controlling the system Arming Disarming

Download Pdf Manuals

image

Related Search

Related Contents

mode d`emploi - Centre Intercommunal de Danse  TB-50 - Tam AG  Optimus SCR-100 Cassette Player User Manual  MyKronoz ZeSplash    取扱説明書ダウンロード  PLATINUM™5 OXYGEN CONCENTRATORS  Samsung Galaxy K Zoom Kasutusjuhend  frenic-vg    

Copyright © All rights reserved.
Failed to retrieve file