1. Temperature and effects will affect lifetime Color Kinetics rates product lifetime using lumen deprecia tion to 50 of original light output When the fixture is running at room temperature using a color wash effect the range of lifetime is in the range of 80 000 100 000 hours This is LED manufacturers test data High output is defined as any LED device that is 1 2 watt or above For more detailed infor mation on source life please see www colorkinetics com lifetime WARRANTY This product is sold pursuant to CK s Standard Terms and Conditions the T amp Cs which may be found at http colorkinetics com howtobuy buy terms and which contain important provisions including among others Limited Warranty exclusions and limitations on CK s liability for damages and restrictions on the remedies that are available to you 1 Guide to Health Safety and Welfare at Pop Concerts and Similar Events HMSO Publications UK
2. tight seal 2 Insert the fixture cable through the dome nut Loosen the dome nut if necessary Pull the cable through the fitting Leave enough cable above the fitting to ensure full fixture head rotation 3 Tighten dome nut to seal the cable After 24 hours tighten the dome nut again to ensure proper sealing force and water tight seal see Fig 1 UQUID TIGHT FITTING Indoor Wall or Ceiling Mount 1 Ensure the junction box is located within 60 feet 18 3m of the power data supply Pull the fixture leader cable through the junction box 2 Using the provided screws attach the mounting bracket of ColorBlast 12 to the junction box Fig 2 Fig 2 aia ia Fastening Screws gt Included E 3 5 Center to center mounting hole spacing Indoor electrical junction box Not included Outdoor Wall or Ceiling Mount For outdoor installations ColorBlast 12 must be used with an outdoor rated junction box and the gasket must be used to ensure a watertight seal 1 Ensure that the junction box is located within 60 feet of the power data supply Thread the leader cable through provided gasket Pull fixture leader cable through the junction box 2 Using the provided screws attach the mounting bracket of ColorBlast 12 to the outdoor rated junction box Fig 3 Fig 3 Fastening Screws
3. Included 5 Gasket Included 3 5 Center to center mounting hole spacing Outdoor electrical junction box Not included Floor Mount When used indoors ColorBlast 12 can be mounted without a junc tion box Ensure that the fixture sits flush to the surface and use mounting hardware suitable for the mounting surface Positioning the Fixture Rotate the light fixture to the desired position Using the provided hex key tighten the set screws located on the base to lock in place Tilt the fixture to the desired angle and tighten the set screws located on the front of housing to lock See Fig 4 for location of set screws NOTE For permanent installations use thread locker to prevent loosening Aim fixture and lock in place Rotate fixture at base lock in place Attaching the Safety Cable Each fixture is designed for use with a safety cable When required by local or state code or by a Structural Engineer attach a safety cable from the fixture to the mounting surface END USER SPECIFIES REQUIRED END TERMINATOR AND ANCHORING 1 Locate the safety cable bracket on rear of the ColorBlast 12 Fig 5 2 Remove the two screws that attach the cable bracket to the fix ture Loop the safety cable over the cable bracket and reattach to the fixture Add thread locker for additional securement of hardware 3 Attach the safety cable to the mounting surface Consult a St
4. lighting Temperature Monitoring For protection from extreme temperatures ColorBlast 12 has been designed with a temperature monitoring feature If operating tem peratures rise to an unsafe level a compensation circuit is triggered and the ColorBlast 12 operation is interrupted causing the lights to turn dull red After 30 minutes the lights will auto cycle and return to full intensity To prevent additional power shutdowns determine the cause of the overheating and correct the problem If any problems occur during usage unplug the product immediately and call Color Kinetics Technical Support Group 1 888 FULL RGB or 617 423 9999 or email us technicalsupport colorkinetics com COLORBLAST 12 SPECIFICATIONS COLOR RANGE 16 7 million 24 bit additive RGB colors continuously variable intensity output range SOURCE High intensity power light emitting diodes LEDs BEAM ANGLE 23 Beam angle frosted 10 clear HOUSING Die Cast Aluminum in black or white finish LENSES Soft focus tempered glass or clear tempered glass CONNECTORS 60 foot 18 3cm Unified power and data cable LISTINGS UL cUL CE COMMUNICATION SPECIFICATIONS DATA INTERFACE Color Kinetics data interface system CONTROL Color Kinetics controllers or other DMX512 RS485 compatible if using Color Kinetics power data supply ELECTRICAL SPECIFICATIONS POWER REQUIREMENT 24VDC POWER CONSUMPTION 50W Max at full intensity full RGB POWER SUPPLY PDS 150e ITEM 109
5. the product s Installation Guide for complete instructions Remember e Consult an Electrical Inspector to review all wiring plans e PDS 150e or PDS 60 24V must be located within 60 feet 18 3m of the ColorBlast 12 fixtures Addressing the Lights Important Before you begin the installation consider the scope of your lighting application and installation Your ColorBlast 12 is set to light number one at the factory Setting the DMX Address POST INSTALLATION ZAPI SAS OR LIGHT SYSTEM COMPOSER 1 After installing the ColorBlast 12 connect power to the power data supply 2 Attach the DMX interface Zapi iPlayer 2 or Smart Jack 3 to the DMX Ethernet IN port on the power data supply or attach the Light System Manager Ethernet system to the Ethernet network 3 Using Zapi or Serial Addressing Software SAS set the light address for each fixture by entering the serial number 4 Using Light System Composer software discover and address all lights attached to the Ethernet system PRE INSTALLATION USING ZAPI OR SAS 1 With power disconnected connect a single ColorBlast 12 fixture or a series of fixtures to a power data supply 2 Attach the DMX interface Zapi iPlayer 2 or Smart Jack 3 to the DMX IN port on the power data supply 3 Connect power to the power data supply 4 Use Zapi or Serial Addressing Software SAS to set the light address for each serial number 5 If addressing individual fixtures disconnect pow
6. 000008 01 PDS 60 24V ITEM 109 000017 00 01 02 ENVIRONMENTAL SPECIFICATIONS TEMPERATURE RANGE 40 F to 122 F 40 C to 50 C operating temperature 4 F to 122 F 20 C to 50 C starting temperature PROTECTION RATING IP66 LED SOURCE LIFE In traditional lamp sources lifetime is defined as the point at which 50 of the lamps fail This is also termed Mean Time Between Failure MTBF LEDs are semiconductor devices and have a much longer MTBF than conventional sources However MTBF is not the only consideration in determining useful life Color Kinetics uses the concept of useful light output for rating source lifetimes Like traditional sources LED output degrades over time lumen depreciation and this is the metric for SSL lifetime LED lumen depreciation is affected by numerous environmental conditions such as ambient tempera ture humidity and ventilation Lumen depreciation is also affected by means of control thermal management current levels and a host of other electrical design considerations Color Kinetics systems are expertly engineered to optimize LED life when used under normal operating conditions Lumen depreciation information is based on LED manufacturers source life data as well as other third party testing Low temperatures and controlled effects have a beneficial effect on lumen depreciation Overall system lifetime could vary substantially based on usage and the environment in which the system is installed
7. COLORBLAST 12 USER GUIDE CHROMACORE BY COLOR KINETICS OPTIBIN BY COLOR KINETICS COLOR KINETICS INCORPORATED 10 MILK STREET SUITE 1100 BOSTON MA 02108 USA TEL 888 FULL RGB TEL 617 423 9999 xe DRY Fax 617 423 9998 INFO COLORKINETICS COM DAMP WWW COLORKINETICS COM Oy WET ITEM 116 000012 00 White Frosted Lens 116 000012 01 Black Frosted Lens 116 000012 02 White Clear Lens 116 000012 03 Black Clear Lens This product is protected by one or more of the following patents U S Patent Nos 6 016 038 6 150 774 and other patents listed at http colorkinetics com patents Other patents pending 2005 2006 Color Kinetics Incorporated All rights reserved Chromacore c US Chromasic Color Kinetics the Color Kinetics logo ColorBlast ColorBlaze ColorBurst ColorCast ColorPlay ColorScape Direct Light iColor iColor Cove LISTED iPlayer Optibin Powercore QuickPlay Sauce the Sauce logo and Smartjuice are 78GF registered trademarks and DiMand EssentialWhite eW IntelliWhite iW and Light Without Limits are trademarks of Color Kinetics Incorporated PUB 000138 00 Rev 02 Specifications subject to change without notice INTRODUCTION Color Kinetics ColorBlast 12 offers wall washing wall grazing spot lighting and large alcove lighting in an easy to install fixture This user guide contains important information about proper instal lation and safe operati
8. e severity of the hazards associated with the products is used DANGER mminently hazardous situation which if not avoided will result in death or serious injury WARNING Potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Potentially hazardous situation which if not avoided may result in minor or moderate injury or property dam age Also used to alert against unsafe practices IGNORING A HAZARD WILL VOID ANY WARRANTY DANGER Ensure that the main power supply is off before installing or wiring the ColorBlast 12 and power data supply WARNING The ColorBlast 12 and power data supply must be installed by a qualified professional in accordance with NEC and relevant local codes WARNING Do not attempt fo install or use the ColorBlast 12 or power data supply until you read and understand the installation instructions and safety labels CAUTION The ColorBlast 12 has no serviceable parts Do not attempt fo open the fixture CAUTION Do not modify alter or attempt to service the ColorBlast 12 CAUTION Never lengthen the ColorBlast 12 cable CAUTION You must use the cable provided with the unit CAUTION Do not use sharp tools near or on the fixture lens CAUTION Do not hot swap Ensure the power supply is off before connecting or disconnecting fixtures CAUTION Do not overload the power data supply NOTE The instructions and precautions set forth in
9. e unit Use of other cables may result in light failure Power Data Cable 18AWG 82mm2 CSA Maximum cable run from PDS 150e to Lights 60 feet DATA 100 to 240VAC TERMINATOR amp nE oooo0 PDS 150e PDS 150e Loop out connection for multiple power data supplies 100 to 240VAC Color Kinetics CETTTTTTTTTTTTTTTTTITE Controller CAT 5 RJ45 Data Cable ROUTINE MAINTENANCE Cleaning Use a soft cloth Clean surface with mild soap and water or window cleaner Lubrication As needed apply light household oil to the hinges IMPORTANT INFORMATION Strobe Warning There is anecdotal evidence which suggests that strobe lighting may induce epileptic symptoms in certain susceptible individu als although no associated product warnings have been issued by the United States government according to the Food and Drug Administration If strobe lights are used some international regulatory agencies recommend keeping flicker rates at or below four flashes per sec ond as less of the flicker sensitive population will then be at risk of an attack This flicker rate applies only to the overall output of any group of lights in direct view However when more than one strobe light is used the flashes should be synchronized End users should also consider issuing a warning alerting audience or viewers to the presence of strobe
10. er and then dis connect the addressed fixture s Repeat steps 1 through 5 NOTE Serial addressing gives you the option of post installation addressing multiple fixtures through a single power data supply or multiple power data supplies using the recorded serial numbers Refer to the Zapi User Guide or SAS Instruction Guide for details Installing the Fixtures DANGER Ensure that main power supply is off before installing or wiring the ColorBlast 12 and power data supply Failure to adhere to these instructions will result in death or serious injury and will void the warranty WARNING The ColorBlast 12 and the power data supply must be installed by a qualified professional in accordance with NEC and relevant local codes Failure to comply could result in death or serious injury and will void the warranty This fixture must be installed by a qualified electrician in accor dance with NEC and relevant local codes for Class 2 power sourc es The ColorBlast 12 can be installed indoors or outdoors When mounting on walls and ceilings use an electrical junction box rated for your application Through Base Cable Assembly For all installations where the cable must go through the canopy base follow the directions below to prevent cable damage and to create a water tight seal for outdoor installations 1 Screw the liquid tight fitting into the canopy base The O ring must be seated against the canopy opening to ensure a water
11. of the supported fixtures e Location of the fixture and method of mounting The ColorBlast 12 can be installed indoors or outdoors on a wall ceil ing or floor Junction boxes and mounting methods vary accord ing to location STEPS TO A SUCCESSFUL INSTALLATION 1 Record the serial numbers and identify fixtures as you unpack them 2 Install the power data supplies 3 Address the lights A Install the fixtures 5 Make electrical connections Recording Serial Numbers 1 Record the serial numbers as you unpack the fixtures Each ColorBlast 12 has a unique serial number programmed at the time of manufacture 2 Write the serial numbers onto a Mapping Grid or use a bar code scanner along with Color Kinetics Serial Addressing Software to record each serial number Color Kinetics Serial Addressing Software and instructions are located at www colorkinetics com support 3 Using the Layout Plan assign the fixture to a layout position in the installation 4 Using a weatherproof label identify the fixture s installation position based on the Layout Plan Place the identifying label in an inconspicuous location noting the order or placement in the installation This step not only minimizes installation mistakes but aids in post installation programming of your lightshows Installing Power Data Supplies Following the Layout Plan install the PDS 150e or PDS 60 24V power data supplies according to state and local codes Refer to
12. on of your new ColorBlast 12 light fixture Included in This Box e ColorBlast 12 and preassembled base with 60 ft 18 3m 3C 18AWG SJTW Cable e 2 8 32 UNC x 1 25 31 75mm LG pan head drive screws for indoor installation e 4 10 24 UNC x 75 19mm LG pan head drive screws for outdoor installation e User Guide e Outdoor JBox Gasket e Hex key Additional Items Needed e 4 10 2cm Electrical junction box rated for your application with 3 5 8 9cm center to center distance for mounting locations e 24VDC power data supply PDS 150e Item 109 000008 01 or PDS 60 24V Item 109 000017 00 01 02 e Controller Color Kinetics or DMX compatible e Light addressing tool Color Kinetics Zapi Item 103 000005 00 US 103 000005 01 EU or Serial Addressing Software SAS with iPlayer 2 or Smart Jack 3 e Adjustable wrench e Philips head drive screwdriver Optional Items e 3 16 OD braided safety cable and hardware as required Scope of This User Guide The goal of this user guide is to explain the steps needed to install the ColorBlast 12 fixture and assure peak performance Its intend ed use is for reference only by persons who are fully qualified This document should never be considered a substitute for any pro visions of a regulation or any applicable state or local code Identification and Warnings of Safety Hazards In accordance with ANSI Z535 4 2002 the following system of identifying th
13. ructural Engineer and refer to applicable standards for your specific application to determine the proper method for mounting the safety cable to the installation surface Safety cables used in the installation must meet the following minimal requirements MATERIAL 316 Stainless Steel SIZE 5 64 inch 0 78 inch nominal diameter or larger minimum break load must be greater than 400 pounds Maximum diam eter is 3 16 inch CONSTRUCTION 7 x 7 49 wires preformed stranded END TERMINATIONS Determined by installer and or owner MOUNTING METHOD Determined by installer or owner Making Electrical Connections ColorBlast 12 is compatible with Color Kinetics power data supplies Connecting Power ColorBlast 12 requires 24VDC After installing the light fixtures connect the power data cable to the power data supply The PDS 150e supports three ColorBlast 12 fixtures Wire one fixture per terminal group see Fig 7 Each PDS 60 24V supports one ColorBlast 12 CAUTION Do not overload the power data supply Doing so will result in product failure and void the warranty NOTE Each light must receive power directly from a power data supply You cannot daisy chain power from one ColorBlast 12 to another The ColorBlast 12 cable contains three color coded wires Fig 6 e Black Common e White Data e Red 24 VDC pRa CAUTION You must use the cable provided with th
14. this installation guide are not necessarily all inclusive all conceivable or relevant to all applications as Color Kinetics cannot anticipate all conceivable or unique situations Owner User Responsibilities It is the responsibility of the contractor installer purchaser owner and user to install maintain and operate the ColorBlast 12 in such a manner as to comply with all state and local laws ordinances regulations and the American National Standard Institute ANSI Safety Code PLANNING THE INSTALLATION The ColorBlast 12 installation requires planning to ensure a timely successful installation with minimal complications and down time Planning Suggestions When planning a ColorBlast 12 installation Color Kinetics suggests doing the following e Consult an Electrical Inspector to review all wiring plans e Refer to local and state codes for installation compliance e Create a Layout Plan drawing e Create a Mapping Grid Use this grid to record serial numbers for easy reference and addressing e Consult Color Kinetics Application Engineering Services as need ed at www colorkinetics com support e Get detailed wiring diagrams and additional support from www colorkinetics com support Installation Considerations e Location of the power data supplies in relationship to lights Each ColorBlast 12 comes with a 60 ft 18 3m power data cable Therefore the power data supply must be located within 60 feet 18 3m