1. 1 General Information naai aeiee e FI nnn 8 IE HG atures sides ne 8 1 2 DeScEIDIIOn cocida iii 8 2 nstallation a aul usn 10 2 1 Connecting the Twisted Pair Line Interface sess 11 22 Connecting the 10 100Base T Ethernet Interface 12 2 3 Connecting Power vivio ata 12 e GCOnDTIBUFAtlOD certet ea ee i i tee DYF teat 13 3 1 Configuring DIP Switch Sl 14 4 Opera Ai e ied 15 43 PowerUp a i teneret dba ee 15 4 2 Front Panel LED Status Monitors esses 15 A SpeciMlcatiOnS uu te pite gei ere dd 16 A 1 LAN Connection LI Y seen 16 A2 Transmission Lane AS aere sues ver Eee aU ae Egon y 16 Variable Rate Ethernet Extender Line Rate 16 A 4 LED Status Indicators oocoooconcnnnonnnnnonononannnonononannnoncnnnnannnncononanonncononns 16 A5 Power Supply x deoa duet i REDE HI LERRA 16 Temperature Range eene 17 ACT Humidity aethere t te eet ts 17 AS DIMENSIONS acepte sterii deest a ii 17 B Interface Pin Assignment essere ethernet nnne 18 B 1 10 100Base T Interfac amp c ott reete rt nh 18 B 2 Line Interface nanenane na a i LI I Finn 18 C Distance Chart Based on 24 AWG 0 5 MM 19 Le MULTI RATE ETHERNET EXTENDER 1 Gene
2. lt gt BLACK BOX MARCH 2011 LB200A R3 Multi Rate Ethernet Extender Ethernet e Ethernet Extender Multi Rat residential environment C This is a Class A device and is not intended for use in a La IN SSS E B 8 CUSTOMER Order toll free in the U S 24 hours 7 A M Monday to midnight Friday 877 877 BBOX SUPPORT FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 INFORMATION Mail order Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com MULTI RATE ETHERNET EXTENDER CE NOTICE The CE symbol on your Black Box equipment indicates that it is in compliance with the Electromagnetic Compatibility EMC directive and the Low Voltage Directive LVD of the European Union EU A Certificate of Compliance is available by contacting Technical Support This device is NOT intended nor approved to be con nected to the PSTN It is intended only for connection to customer premise equipment WARNING MULTI RATE ETHERNET EXTENDER e This device contains no user serviceable parts This device can only be repaired by qualified service per sonnel Do not open the device when the power cord is con nected For systems without a power switch and without an external power adapter line voltages are present within the device when the power cord is connected
3. able via DIP switch settings Distance 5 750 ft 1 7 km at 1 Mbps upstream 4 Mbps downstream Note Distances depend on selected line rate and line conditions See Appendix D on page 19 for details A 4 LED Status Indicators Power Green Line Link Green Ethernet Link Green amp Activity Flashing Green Remote Green Local Green A 5 Power Supply External AC and DC options AC 120 VAC 220 VAC and UI 120 240 VAC DC 12 VDC 24 VDC and 48 VDC Power consumption 860mA at 5V o MULTI RATE ETHERNET EXTENDER A 6 Temperature Range 0 40 C A 7 Humidity Up to 90 non condensing A 8 Dimensions 1 58H x 4 16W x 3 75D in 10 6H x 4 1W x 8 8D cm MULTI RATE ETHERNET EXTENDER B Interface Pin Assignment B 1 10 100Base T Interface RJ 45 e Pin 1 TX Pin 2 TX Pin 3 RX Pin 6 RX Pins 4 5 7 8 no connection B 2 Line Interface RJ 45 Pin 4 RING Pin 5 TIP Pins 1 2 3 6 7 8 no connection MULTI RATE ETHERNET EXTENDER C Distance Chart Based on 24 AWG 0 5 MM Throughput at Max Rate Distance Feet Distance megabits km per second 4 1 5 500 4 00 DS 1 6 km 1 00 US 9 1 5 750 8 98 DS 1 7 km 1 0 US 16 2 4 700 15 92 DS 1 4 km 2 0 US 6 6 5 500 5 98 DS 1 6 km 5 98 US 10 10 5 000 9 99 DS 1 5 km 9 99 US 15 15 4 250 14 96 DS 1 2 km 14 96 US Note The actual
4. anera que la tierra fisica y la polarizaci n del equipo no sea eliminada 13 Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos poniendo particular atenci n a los contactos y recept culos donde salen del aparato 14 El equipo el ctrico debe ser limpiado nicamente de acuerdo a las recomen daciones del fabricante 554 _ MULTI RATE ETHERNET EXTENDER 15 En caso de existir una antena externa deber ser localizada lejos de las lineas de energia 16 El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo 17 Cuidado debe ser tomado de tal manera que objectos liquidos no sean derra mados sobre la cubierta u orificios de ventilaci n 18 Servicio por personal calificado deber ser provisto cuando A El cable de poder o el contacto ha sido da ado u B Objectos han ca do o l quido ha sido derramado dentro del aparato o C El aparato ha sido expuesto a la lluvia o D El aparato parece no operar normalmente o muestra un cambio en su desempe o o E El aparato ha sido tirado o su cubierta ha sido da ada MULTI RATE ETHERNET EXTENDER CONTENTS CEJNOUCS onion ete nde ned ne E ae S 2 Radio and TV Interference sess 2 Trademarks Used In This Manual eee 4 Normas Oficiales Mexicanas NOM Electrical Safety Statement 5
5. distance and link performance may vary depending on the environment and type gauge of wire used Note DS downstream US upstream lt BLACK BOX O Copyright 2011 Black Box Corporation All rights reserved Sq es ees 1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746
6. e For devices with an external power adapter the power adapter shall be a listed Limited Power Source The mains outlet that is utilized to power the device shall be within 10 feet 3 meters of the device shall be easily accessible and protected by a circuit breaker in com pliance with local regulatory requirements e For AC powered devices ensure that the power cable used meets all applicable standards for the country in which it is to be installed e For AC powered devices which have 3 conductor power plugs L1 L2 GND or Hot Neutral amp Safety Protective Ground the wall outlet or socket must have an earth ground WARNING e For DC powered devices ensure that the interconnect ing cables are rated for proper voltage current antici pated temperature flammability and mechanical serviceability WAN LAN amp PSTN ports connections may have haz ardous voltages present regardless of whether the device is powered ON or OFF PSTN relates to inter faces such as telephone lines FXS FXO DSL xDSL T1 E1 ISDN Voice etc These are known as hazard ous network voltages and to avoid electric shock use caution when working near these ports When discon necting cables for these ports detach the far end con nection first e Do not work on the device or connect or disconnect cables during periods of lightning activity MULTI RATE ETHERNET EXTENDER E WARNING In accordance with the requirement
7. erside of the Ethernet Extender see Figure 5 Figure 5 Removing protective cover Figure 6 shows the orientation of the DIP switches in the On and Off positions S1 Front Rear Push toggle up ON for ON position Push toggle down for OFF position Figure 6 DIP switch orientation 65 MULTI RATE ETHERNET EXTENDER 3 1 Configuring DIP Switch S1 DIP switch S1 is where you configure the line rate The following tables describe the configuration for the Ethernet Extender Table 1 Firmware Configuration S1 1 1 2 1 3 1 4 Position Master Rate Slave ON Slave CPE 4 1 9 1 16 2 6 6 10 10 15 15 OFF Master Rate Control See table below CO Rat S1 2 51 3 51 4 ps DS US ON ON ON OFF 6 6 OFF OFF ON 10 10 ON ON ON 15 15 DS Downstream US Upstream MULTI RATE ETHERNET EXTENDER 4 Operation Once the Multi Rate Ethernet Extenders are properly installed they should oper ate transparently No user settings required This section describes reading the LED status monitors 4 1 Power Up Before applying power to the Ethernet Extender review section 2 3 Connecting Power on page 12 to verify that the unit is connected to the appropriate power source 4 2 Fron
8. et Ethernet LB200A Twisted Pair 2 wire TEM P Remote Network Figure 1 Typical application The pair of LB200A models work together to create a transparent extension between two peered Ethernet LANs Figure 1 shows a typical point to point applica tion MULTI RATE ETHERNET EXTENDER 2 Installation The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica tion with respect to voltage current anticipated tem perature flammability and mechanical serviceability WARNING To install the LB200A Ethernet Extender do the following 1 Connect the line interface between the units refer to section 2 1 Connect ing the Twisted Pair Line Interface on page 11 Note See Figure 2 for the unit s rear panel arrangements 2 Connect the Ethernet interface refer to section 2 2 Connecting the 10 100Base T Ethernet Interface on page 12 3 Connect the power plug refer to section 2 3 Connecting Power on page 12 Line twisted pair RJ 45 interface Dual 10 100 Ethernet ports Figure 2 Multi Rate Ethernet Extender rear panel MULTI RATE ETHERNET EXTENDER 2 1 Connecting the Twisted Pair Line Interface The Multi Rate Ethernet Extender supports communication between two peer Ethernet LAN sites over a distance of up to 5 750 ft 1 7 km over 24 AWG 0 5 mm twisted pair wire Note Actual distance and link performance
9. may vary depending on the envi ronment and type gauge of wire used Follow the steps below to connect the Ethernet Extender interfaces Note The Ethernet Extender units work in pairs One of the units must be con figured as a L Local unit and the other unit must be configured as aR Remote unit 1 To function properly the two Ethernet Extenders must be connected together using twisted pair unconditioned dry metal wire between 19 0 9mm and 26 AWG 0 4mm Leased circuits that run through signal equalization equipment are not acceptable 2 The Ethernet Extender is equipped with an RJ 45 interface jack that can be used on the Line interface The Line interface is a two wire interface Observe the signal pin relationships on the Line interface jack The RJ 45 connector on the Ethernet Extender s twisted pair interface is polar ity insensitive and is wired for a two wire interface The signal pin relationship is shown in Figure 3 no connection no connection 1 2 3 no connection 4 2 Wire RING 5 6 DA 2 Wire TIP no connection no connection 8 no connection Figure 3 RJ 45 twisted pair line interface MULTI RATE ETHERNET EXTENDER 2 2 Connecting the 10 100Base T Ethernet Interface The shielded RJ 45 ports labeled Ethernet are the Auto MDIX10 100Base T inter face These ports are designed to connect directly to a 10 100Base T network Figure 4 sh
10. ows the signal pin relationships on this interface You may connect this port to a hub or PC using a straight through or crossover cable that is up to 328 ft long 1 TX data output from Line Driver 1 i 2 TX data output from Line Driver i 3 RX data input to Line Driver 3 p 4 no connection 5 no connection 0 6 RX data input to Line Driver 7 no connection 8 no connection 4 5 6 7 8 Figure 4 Ethernet Extender 10 100Base T RJ 45 Connector Pinout 2 3 Connecting Power The Ethernet Extender does not have a power switch so it powers up as soon as it is plugged in An external AC or DC power supply is available separately This connection is made via the barrel jack on the rear panel of the Ethernet Extender No configura tion is necessary for the power supply DC power supplied via the power supply jack to the Ethernet Extender must meet the following requirements DC power supplied must be regulated 5 VDC 5 1 0A minimum Center pin is 5V The barrel type plug has a 2 5 5 5 10mm I D O D Shaft Length dimensions MULTI RATE ETHERNET EXTENDER 3 Configuration The Ethernet Extender has four DIP switches S1 for configuring the unit for a wide variety of applications This section describes switch locations and explains the different configurations Using a small flat tip screwdriver remove the protective cover located on the und
11. ral Information Thank you for your purchase of this Black Box product If any questions arise during installation or use of the unit contact Black Box Tech Support at 724 746 5500 1 1 Features Multi Rate Ethernet extender Easy to configure Auto MDIX Ethernet Configurable 10 100 Full Half and Auto Negotiating Ethernet Extends network connections up to 5 750 ft 1 7 km over 2 wire 24 AWG unconditioned lines Switch selectable line rates up to 16 Mbps Symmetric or asymmetric settings via DIP switch Transparent operation LED indicators for Power Link Ethernet Link amp Activity and Remote Local 1 2 Description The Black Box LB200A modems provide high speed LAN connections between peered Ethernet LANs remote PCs or any other network enabled 10 100Base T device Operating in pairs one LB200A is configured as the L Local unit located at one end of the LAN extension and the other LB200A is configured as the R Remote unit at the other end The LB200A is configured as a L or R via the switch on the bottom of the unit These units can automatically forward LAN broadcasts multi casts and frames across a 2 wire voice grade twisted pair link The data is passed transparently unmodified through the LB200As The LB200As automatically add and delete MAC addresses only passing packets across the Line link that are meant for the remote peered LAN MULTI RATE ETHERNET EXTENDER 10 100Base TX 10 100Base TX Ethern
12. rato el ctrico y en sus instrucciones de operaci n deben ser respetadas 4 Todas las instrucciones de operaci n y uso deben ser seguidas 5 El aparato el ctrico no deber ser usado cerca del agua por ejemplo cerca de la tina de ba o lavabo s tano mojado o cerca de una alberca etc 6 El aparato el ctrico debe ser usado nicamente con carritos o pedestales que sean recomendados por el fabricante 7 El aparato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante 8 Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en las instrucciones de operaci n Todo otro servicio deber ser referido a personal de servicio calificado 9 El aparato el ctrico debe ser situado de tal manera que su posici n no interfi era su uso La colocaci n del aparato el ctrico sobre una cama sof alfombra o superficie similar puede bloquea la ventilaci n no se debe colocar en libre ros o gabinetes que impidan el flujo de aire por los orificios de ventilaci n 10 El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor 11 El aparato el ctrico deber ser connectado a una fuente de poder s lo del tipo descrito en el instructivo de operaci n o como se indique en el aparato 12 Precauci n debe ser tomada de tal m
13. s of council direc tive 2002 96 EC on Waste of Electrical and Electronic Equipment WEEE ensure that at end of life you sepa rate this product from other waste and scrap and deliver to the WEEE collection system in your country for recy cling Electrostatic Discharge ESD can damage equipment and impair electrical circuitry It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures Do the fol lowing to prevent ESD e Always follow ESD prevention procedures when removing and replacing cards Wear an ESD preventive wrist strap ensuring that it makes good skin contact Connect the clip to an unpainted surface of the chassis frame to safely chan nel unwanted ESD voltages to ground To properly guard against ESD damage and shocks the wrist strap and cord must operate effectively If no wrist strap is available ground yourself by touching the metal part of the chassis TRADEMARKS USED IN THIS MANUAL All applied for and registered trademarks are the property of their respective owners MULTI RATE ETHERNET EXTENDER NORMAS OFICIALES MEXICANAS NOM ELECTRICAL SAFETY STATEMENT Instrucciones De Seguridad 1 Todas las instrucciones de seguridad y operaci n deber n ser le das antes de que el aparato el ctrico sea operado 2 Las instrucciones de seguridad y operaci n deber n ser guardadas para ref erencia futura 3 Todas las advertencias en el apa
14. t Panel LED Status Monitors The Ethernet Extender features six front panel LEDs that monitor power the Ethernet signals the line connection and the remote local setting Figure 7 shows the front panel location of each LED Table 2 describes the LED func tions BLACK BOX Multi Rate Ethernet Extender oo ye P d e O O OO A AN Power Link Ethernet 1 Ethernet 2 Local Remote LED LED LED LED LED LED Figure 7 Ethernet Extender front panel Table 2 Front panel LED description LED Status Description Power Green he device IS powered on Off The device is powered off Link Green The port is connected Blinking Green Data transceiving Off No valid link on this port Ethernet Green The port is connected Blinking Green Data transceiving Local Green The device acts in Local mode Off Local mode is off Remote Green The device acts in Remote mode Off Remote mode is off Once the unit connects to a power source the Link LED will blink as the Extender automatically looks for the other unit in the pair 65 MULTI RATE ETHERNET EXTENDER A Specifications A 1 LAN Connection Two shielded RJ 45 10 100Base T IEEE 802 3 Ethernet Line Connection RJ 45 A 2 Transmission Line Two wire unconditioned twisted pair A 3 Multi Rate Ethernet Extender Line Rate Line Rate 15 15 Mbps upstream downstream Additional five line rates are avail