Home

AT Commands User Manual VR1.0.9

image

Contents

1. or CMS ERROR lt err gt Test CPMS CPMS list of The Test command supported lt mem1 gt s list of lists the supported supported lt mem2 gt s list of memory storage for supported lt mem3 gt s lt mem1 gt lt mem2 gt OK and lt mem3 gt or CMS ERROR lt err gt The following table shows the CPMS parameters lt Parameter gt Description lt mem1 gt Memory from which messages are read and deleted Supported values are SM BM ME SR The default value at power up is SM lt mem2 gt Memory to which writing operation is made Supported value is SM ME The default value at power up is SM lt mem3 gt Memory to which received SMS are stored unless forwarded directly to TE Supported value is SM BM ME SR The default value at power up is SM BM Broadcast message storage SM U SIM message storage ME ME message storage SR status report storage Example H3 Family AT Commands User Manual Page 122 of 375 FIDCCON AT CPMS SM CPMS 5 50 5 50 5 50 OK AT CPMS CPMS SM 5 50 SM 5 50 SM 5 50 OK 7 1 3 CMGF Message Format This command is a basic command The Set command handles the selection of the message format used with send list read and write commands as well as the format of unsolicited result codes resulting from message receipts The H3xx supports both PDU mode where entire TP data uni
2. lt Parameter gt Description lt cid gt Anumeric parameter that specifies a particular PDP context definition The value is from 1 to 10 For lt cid gt refer to defined values under CGDCONT command lt precedence gt Anumeric parameter that specifies the precedence class lt delay gt Anumeric parameter that specifies the delay class lt reliability gt Anumeric parameter that specifies the reliability class lt peak gt Anumeric parameter that specifies the peak throughput class lt mean gt Anumeric parameter that specifies the mean throughput class Example AT CGQMIN CGQMIN IP 0 3 0 4 0 5 0 9 0 18 OK AT CGQMIN H3 Family AT Commands User Manual Page 266 of 375 FIDCCON CGQMIN 1 2 4 3 9 10 CGQMIN 2 2 4 3 9 10 OK 12 2 4 CGQREQ Quality of Service Profile Requested This command enables the terminal to specify a Quality of Service Profile that is used when the ME sends an Activate PDP Context Request message to the network Command Syntax Response Action Remarks Set AT CGQREQ lt c OK The Set command specifies a profile for id gt lt precedence ae the context identified by the local context gt lt delay gt lt relia identification parameter lt cid gt As this is bility gt lt peak gt lt PPE ERRATE the same parameter that is used in the mean gt II CGDCONT command the CGQREQ command is effectively an extension of the CGDCONT comman
3. lt Parameter gt Description 0 to 143 TP VP 1 x 5 minutes i e 5 minutes intervals up to 12 hours 144 to 167 12 hours TP VP 143 x 30 minutes 168 to 196 TP VP 166 x 1 day 197 to 255 TP VP 192 x 1 week Example AT CSMP CSMP 17 167 0 0 default values for SMS SUBMIT H3 Family AT Commands User Manual Page 129 of 375 FIDCCON AT CSMP2 1 256 0 0 CMS ERROR numeric parameter out of bounds AT CSMP OK AT CSDH 1 OK AT CMGF 1 OK AT CMGW 15820447141 gt ABC Z CMGW 6 OK AT CMGR 6 CMGR STO UNSENT 15820447141 129 17 0 0 167 8613800755500 145 3 ABC OK 7 1 6 CSDH Show Text Mode Parameters This command controls whether detailed header information is shown in text mode result codes Command Syntax Response Action Remarks Set CSDH lt sho OK The set command controls whether w gt or detailed header information is shown in text mode result codes CMS ERROR lt err gt Read AT CSDH CSDH lt show gt The read command returns the current OK lt show gt parameter value Test AT CSDH CSDH list of supported lt show gt s OK H3 Family AT Commands User Manual Page 130 of 375 FIDCCON The following table shows the CSDH parameters lt Parameter gt Description lt show gt 0 Means do not show header values defined in commands CSCA and CSMP lt sca gt lt tosca gt lt fo gt lt vp gt
4. FIDCCON REL SYNC lt priority gt lt subaddr gt lt satype gt synchronous non transparent VOICE lt priority gt lt subaddr gt lt satype gt normal voice TS 11 eee voice followed by data BS 81 XXX is ASYNC SYNC REL lt priority gt lt subaddr gt lt satype gt SYNC REL ASYNC alternating voice data voice first BS 61 ALT VOICE XXX Leproniy gt Lssukaddi SaNy ber il alternating voice data data first BS 61 GPRS lt PDP_type gt lt PDP_addr gt lt L2P gt lt APN gt GPRS network request for PDP context activation VGC voice group call TS 91 lt GCA gt lt Gid gt lt ackflag gt lt priority gt voice broadcast call TS 92 VBC lt GCA gt lt Gid gt lt ackflag gt lt priority gt The optional lt priority gt indicates the EMLPP priority level of the incoming call by paging notification or setup message lt subaddr gt string type subaddress of format specified by lt satype gt lt satype gt type of subaddress octet in integer format lt PDP_type gt lt PDP_addr gt and lt APN gt are as defined in the Define PDP Context CGDCONT command The optional lt L2P gt proposes a layer 2 protocol to use between the MT and the TE It is defined in the Enter GPRS Data Mode CGDATA command If the MT is unable to announce to the TE the network s request for example it is in V 250 online data state the MT shall reject the request N
5. NOT_SUBSCRIBED 29 SERVICE_UNAVAILABLE 31 SERVICE_NOT_SUPPORTED 32 PREPAY_LIMIT_REACHED 33 INCOMPATIBLE_DEST 35 ACCESS_ DENIED 43 FEATURE_NOT_AVAILABLE 45 WRONG _CALL_ STATE 46 SIGNALING_ TIMEOUT 47 MAX_MPTY_PARTICIPANTS_EXCEEDED 48 SYSTEM_FAILURE 49 DATA_MISSING 50 BASIC_SERVICE_NOT_PROVISIONED 51 ILLEGAL_SS_OPERATION 52 SS_INCOMPATIBILITY 53 SS_NOT_AVAILABLE 54 SS_SUBSCRIPTION_VIOLATION 55 INCORRECT_PASSWORD 56 TOO_MANY_PASSWORD_ATTEMPTS 57 PASSWORD_REGISTRATION_FAILURE 58 ILLEGAL_EQUIPMENT 59 H3 Family AT Commands User Manual Page 103 of 375 FIDCCON UNKNOWN_SUBSCRIBER 60 ILLEGAL_SUBSCRIBER 61 ABSENT_SUBSCRIBER 62 USSD_BUSY 63 CANNOT_TRANSFER_MPTY_CALL 65 BUSY_WITH_UNANSWERED_CALL 66 UNANSWERED_CALL_PENDING 68 USSD_CANCELED 69 PRE_EMPTION 70 OPERATION _NOT_ALLOWED 71 NO_FREE_BEARER_AVAILABLE 72 NBR_SN_EXCEEDED 73 NBR_USER_EXCEEDED 74 Call Control by SIM Causes NOT_ALLOWED_BY_CC 75 MODIFIED_TO_SS_BY_CC 76 MODIFIED_TO_CALL_BY_CC 77 CALL_MODIFIED_BY_CC 78 App Cause FDN_FAILURE 90 Example H3 Family AT Commands User Manual Page 104 of 375 FIDCCON AT CUSD 1 00 0549598743 CUSD 0 Connecting 15 CUSD 0 Connected 15 CLCC 1 1 4 0 0 0545550099 129 gt Call from USSD server RING ATA gt answer to the server when answered the server call to 0549598743 OK CLCC 1 1 0 0 0 0545550099 129 NO CARRIER C
6. CGEV NW DEACT lt PDP_type gt lt PDP_addr gt lt cid gt The network has forced a context deactivation The lt cid gt that wa s used to activate the context is provided if known to the MT CGEV ME DEACT lt PDP_type gt lt PDP_addr gt lt cid gt The mobile termination has forced a context deactivation The lt ci d gt that was used to activate the context is provided if known to the MT CGEV NW DETACH The network has forced a PS detach This implies that all active c ontexts have been deactivated These are not reported separately ETSI 3GPP TS 27 007 version 7 6 0 Release 7 147 ETSI TS 127 007 V 7 6 0 2010 04 CGEV ME DETACH The mobile termination has forced a PS detach This implies that all active contexts have been deactivated These are not reported separately CGEV NW CLASS lt class gt The network has forced a change of MT class The highest availa ble lt class gt is reported see CGCLASS CGEV ME CLASS lt class gt The mobile termination has forced a change of MT class The hig hest available lt class gt is reported see CGCLASS CGEV ME PDN ACT lt cid gt lt re ason gt lt cid_other gt The mobile termination has activated a context The context repre sents a PDN connection in LTE or a Primary PDP context in GSM UMTS The lt cid gt for this context is provided to the TE This event is sent either in result of expl
7. FIDCCON AT MIPODM 1 0 0 0 0 0 0 Listens to any port at any IP OK MIPODM 1 1 122 221 32 64 1200 Remote side connected to the listen socket 13 18 MIPXOFF Flow Control Xoff This command is the unsolicited response that the H3xx sends to the terminal to stop sending data when it does not have enough memory to process new MIPSEND requests The H3xx uses the accumulating buffer prior to pushing data into the protocol stack This memory resource is protected by a Xoff_upper watermark Event MIPXOFF lt Socket ID gt Example MIPXOFF 1 The H3xx detects that the accumulating buffer 1 has reached its Xoff watermark From this point the terminal is not allowed to send data until it receives the MIPXON command 13 19 MIPXON Flow Control Xon This command is the unsolicited event that the H3xx sends to the terminal when it detects that it has free memory in the accumulating buffer and can process new MIPSEND requests after the MIPXOFF event Event MIPXON lt Socket ID gt Example MIPXON 1 The H3xx pushed the data into the protocol stack on socket 1 and is able to handle more data from the terminal H3 Family AT Commands User Manual Page 343 of 375 FIDCCON 14 FTP Command 14 1 FIP Introduction File Transfer Protocol FTP is a standard network protocol used to transfer files from one host to another host provided by TCP IP it is an application protocol of TCP IP protocol which makes
8. Supported in R7 PS a numeric parameter used to indicate confirmat H3 Family AT Commands User Manual Page 290 of 375 FIDCCON 1 CGDCONT and CGDSCONT commands content of submitted SDUs for a PDP context This parameter should be provided if the Traffic class is specified as interactive refer 3GPP TS 24 008 subclause 10 5 6 5 0 PDP context is not optimized for confirmat default value PDP context is optimized for confirmat lt PDP_type gt see Example AT CGEQREQ CGEQREQ IP 0 4 1 63 in 1 kbps steps 64 568 in 8 kbps steps 576 8640 in 64 kbps steps 1 63 in 1 kbps steps 64 568 in 8 kbps steps 576 8640 in 64 kbps steps 8700 16000 in 100 kbps steps 1 63 in 1 kbps steps 64 568 in 8 kbps steps 576 8640 in 64 kbps steps 1 63 in 1 kbps steps 64 568 in 8 kbps steps 576 8640 in 64 kbps steps 8700 16000 in 100 kbps steps 0 1 10 1500 1502 1510 1520 1E6 1E5 1E4 1E3 7E3 1E2 1E1 6E8 1E 6 1E5 1E4 5E3 4E3 1E3 5E2 1E2 0 2 10 150 in 10 ms steps 200 950 in 50 ms steps 1000 4000 in 50 ms steps 0 3 0 1 0 1 OK 12 2 13 CGEQNEG G Quality of Service Profile Negotiated This command allows the TE to retrieve the negotiated QoS profiles returned in the Activate PDP Context Accept message Command Syntax Response Action Remarks Set AT CGEQNEG lt cid gt lt cid gt T M CGEQNEG lt cid gt lt Traffic
9. lt d_comp gt Numeric parameter that controls PDP data compression O off default if value is omitted H3 Family AT Commands User Manual Page 263 of 375 FIDCCON 1 on manufacturer preferred compression 2 V 42 bis Other values are reserved The default value is 0 lt h_comp gt a numeric parameter that controls PDP header compression O off default if value is omitted 1 on manufacturer preferred compression 2 RFC1144 applicable for SNDCP only 3 RFC2507 4 RFC3095 applicable for PDCP only Other values are reserved lt pd1 gt lt pdN gt lt pd1 gt lt pdN gt zero to N string parameters whose meanings are specific to the lt PDP_type gt Example AT CGDCONT OK Only without any set command AT CGDCONT 1 IP CMNET OK AT CGDCONT 2 IP CMWAP OK AT CGDCONT CGDCONT 1 IP CMWAP 0 0 0 0 0 0 CGDCONT 2 IP CMNET 0 0 0 0 0 0 OK AT CGACT 1 OK AT CGDCONT CGDCONT 1 IP CMWAP 10 230 50 116 0 0 CGDCONT 2 IP CMNET 10 3 97 156 0 0 OK H3 Family AT Commands User Manual Page 264 of 375 FIDCCON AT CGDCONT CGDCONT 1 10 IP 0 0 1 OK 12 2 3 CGQMIN Quality of Service Profile Min Acceptable This command enables the terminal to specify the minimum acceptable profile which is checked by the ME against the negotiated profile returned in the Activate PDP Context Accept messa
10. Command Syntax Response Action Set CBAUD lt n gt OK CBAUD lt rate gt or CME ERROR lt err gt Read CBAUD CBAUD lt rate gt OK Test CBAUD CBAUD list of supported lt n gt s list of supported lt rate gt s OK FIDCCON The following table shows the CBAUD parameters lt Parameter gt Description lt n gt lt rate gt 0 Auto baud rate 1 Auto baud rate 2 300 3 1200 4 2400 5 4800 6 9600 7 19200 8 38400 9 Auto baud rate 10 57600 11 115200 12 230400 13 460800 14 921600 The default value is 115200 10 1 2 IPR Local Terminal Serial Port Rate This command is responsible for setting and saving the request baud rate The numeric extended format parameter specifies the data rate at which the H3xx accepts Specifying a value of 9 disables the function and allows automatically rate detectable only The specified rate takes effect following the issuing of any result code s associated with the current command line H3 Family AT Commands User Manual Page 204 of 375 FIDCCON The specified lt rate gt value is the rate in bits per second at which the terminal H3xx interface operates for example 19200 or 115200 The rates supported by H3xx are manufacturer specific However the IPR parameter permits setting any rate supported by H3xx during online operation The UART is configured to rates of 300 1200 2400
11. Command Syntax Response Action Set AT MSDNS lt Socket_ID gt lt OK Primary_DNS_server_IP gt lt Sn Secondary_DNS_server_ IP gt 1 CME ERROR lt err gt Read AT MSDNS MSDNS 1 lt Primary_DNS_server_IP gt lt Secondary_DNS_ serve r_IP gt lt CR gt lt LF gt MSDNS 2 lt Primary_DNS_server_IP gt lt Secondary_DNS_ serve r_IP gt lt CR gt lt LF gt MSDNS 3 lt Primary_DNS_server_IP gt lt Secondary_DNS_ serve r_IP gt lt CR gt lt LF gt MSDNS 4 lt Primary_DNS_server_IP gt lt Secondary_DNS_ serve r_IP gt lt CR gt lt LF gt H3 Family AT Commands User Manual Page 338 of 375 FIDCCON MSDNS 5 lt Primary_DNS_server_IP gt lt Secondary_DNS_ serve r_IP gt lt CR gt lt LF gt lt CR gt lt LF gt OK Test AT MSDNS MSDNS List of supported lt Socket_id gt s lt IP gt lt IP gt OK The following table shows the MSDNS parameters lt Parameter gt Description lt Socket_ID gt A unique number that identifies a connection provided by the terminal application 0 Invalid socket number 1 2 3 4 Valid socket number 5 Valid socket number dedicated to MPING lt Primary_DNS_server_IP gt lt S IP of the destination site in the format AAA BBB CCC DDD The econdary_DNS_server_IP gt range of each octant is 0 255 The value can be written in 1 2 or 3 digits Example AT MSDNS MSDNS 1 5 lt IP gt lt IP gt
12. OK or CME ERROR lt err Test AT CGPADDR CGPADDR list of defined The Test command returns the lt cid gt s list of defined lt cid gt s OK The following table shows the CGPADDR parameters lt Parameter gt Description lt cid gt A numeric parameter that specifies a particular PDP context definition If no lt cid gt is specified the addresses for all defined context are returned H3 Family AT Commands User Manual Page 274 of 375 FIDCCON lt PDP_address gt A string that identifies the MT in the address space applicable to the PDP The address may be static or dynamic For a static address it will be the one assigned during the last PDP context activation that used the context definition referred to by lt cid gt lt PDP_address gt is omitted if none is available Example AT CGPADDR CGPADDR 1 2 OK AT CGPADDR 1 CGPADDR 1 0 0 0 0 OK 12 2 9 CGANS Manual response to a network request for PDP context activation This command requests the MT to respond to a network request for Packet Domain PDP context activation which has been signalled to the TE by the RING or CRING unsolicited result code Command Syntax Response Action Remarks Set AT CGANS OK The set command requests the MT to lt response gt lt Or respond to a network request for L2P gt lt cid gt Packet Domain PDP context activation CME ERROR lt
13. e g AT CGEQMIN 32 refer 3GPP TS 24 008 subclause 10 5 6 5 lt Delivery order gt Anumeric parameter that indicates whether the UMTS bearer shall provide in sequence SDU delivery or not 0 no 1 yes Other values are reserved lt Maximum SDU size gt Anumeric parameter 1 2 3 that indicates the maximum allowed SDU size in octets refer 3GPP TS 24 008 subclause 10 5 6 5 lt SDU error ratio gt Astring parameter that indicates the target value for the fraction of SDUs lost or detected as erroneous SDU error ratio is defined only for conforming traffic The value is specified as mEe As an example a target SDU error ratio of 5 10 3 would be specified as 5E3 e g AT CGEQMIN 5E3 refer 3GPP TS 24 008 subclause 10 5 6 5 lt Residual bit error ratio gt Astring parameter that indicates the target value for the undetected bit error ratio in the delivered SDUs If no error detection is requested Residual bit error ratio indicates the bit error ratio in the delivered SDUs The value is specified as mEe As an example a target residual bit error ratio of 5 10 3 would be specified as 5E3 e g ATtCGEQMING 5E3 refer 3GPP TS 24 008 subclause 10 5 6 5 H3 Family AT Commands User Manual Page 283 of 375 FIDCCON lt Delivery of erroneous Anumeric parameter that indicates whether SDUs detected as erroneous SDUs gt shall be de
14. lt Traffic class gt a numeric parameter that indicates the type of application for which the UMTS bearer service is onfirmat 0 conversational 1 streaming 2 interactive 3 background Other values are reserved lt Maximum bitrate UL gt A numeric parameter that indicates the maximum number of kbits s delivered to UMTS up link traffic at a SAP As an example a bitrate of 32kbit s would be specified as 32 e g AT CGEQMIN 32 refer 3GPP TS 24 008 subclause 10 5 6 5 lt Maximum bitrate DL gt Anumeric parameter that indicates the maximum number of kbits s H3 Family AT Commands User Manual Page 282 of 375 FIDCCON delivered by UMTS down link traffic at a SAP As an example a bitrate of 32kbit s would be specified as 32 e g AT CGEQMIN 32 refer 3GPP TS 24 008 subclause 10 5 6 5 lt Guaranteed bitrate UL gt Anumeric parameter that indicates the guaranteed number of kbits s delivered to UMTS up link traffic at a SAP provided that there is data to deliver As an example a bitrate of 32kbit s would be specified as 32 e g AT CGEQMIN 32 refer 3GPP TS 24 008 subclause 10 5 6 5 lt Guaranteed bitrate DL gt Anumeric parameter that indicates the guaranteed number of kbits s delivered by UMTS down link traffic at a SAP provided that there is data to deliver As an example a bitrate of 32kbit s would be specified as 32
15. When AT amp C is set to 0 the DCD signal is always ON When AT amp C is set to 1 the DCD is activated in online mode When AT amp C is set to 2 the DCD is activated only when the PDP context is achieved temporary IP address is received Note If amp C is set to 2 when a CSD call is set DCD will always remain OFF Note For H350 xxx 10 this command is not supported Command Syntax Response Action Set AT amp C lt param gt OK Read AT amp C amp C lt param gt Test AT amp C amp C list of supported lt param gt s The following table shows the amp C parameters lt Parameter gt Description lt param gt DCD signal ON 0 DCD is forced ON at all times 1 DCD is set to ON when H3 Family AT Commands User Manual Page 209 of 375 FIDCCON a ACSD carrier is detected b AGPRS external session is being established H3xx enters PPP mode TE is about to send an LCP configure request to H3xx GPRS connection is not yet established DCD is set to OFF when a NoCSD carrier is detected b H3xx has lost its GPRS connection with the network PDP context was deactivated and the IP address is cancelled 2 DCD is set to ON when H3xx establishes a GPRS connection with the network PDP context is activated and the IP address is received from the network DCD is set to OFF when H3xx has lost its GPRS connection with the network PDP context was deactivated and the IP
16. BODYSARWCDMA 20 20 20 20 OK AT BODYSARWCDMA2 23 20 18 15 OK 10 6 3 BODYSARON Switch On Off BODYSAR Function This command is used for switch on off the BODYSAR function For Set command the value is volatile BODYSAR is switched off for default And when BODYSAR is switched on the module max tx power will no greater than the threshold set by BODYSARGSM and BODYSARWCDMA And when BODYYSAR function is switched off the module will recovery the default max tx power Command Syntax Response Action Remarks Set BODYSARON lt O_ OK N gt or ERROR Read BODYSARON BODYSARON lt ON gt OK H3 Family AT Commands User Manual Page 236 of 375 FIDCCON Test BODYSARON BODYSARON 0 1 OK The following table shows the BODYSARGSM parameters lt Parameter gt Description lt ON gt 1 off Switch on off the function 0 on default value Note for H350 xxx 10 PIN37 is also used to switch on off BODYSAR function when input a high level the module will switch off the BODYSAR function and when input a low level BODYSAR will be switched on If you want to switch off the BODYSAR function you should keep PIN37 and BODYSARON both to be OFF mode Example AT BODYON BODYSARON 0 1 OK AT BODYSARON BODYSARON OK 0 AT BODYSARON 1 OK H3 Family AT Commands User Manual Page 237 of 375 FIDCCON 11 Audio 1
17. MDC 1 OK AT MDC 0 OK ATD lt number gt OK OK AT MDC MDC 0 OK 5 3 18 MHUP H3xx Hung UP call This command hung up specific call or all calls and reported a specific disconnect cause to the NW Note For H350 xxx 10 H380 this command is not supported Command Syntax Response Action Remarks Set AT MHUP lt ca OK use gt lt call_id gt oe CME ERROR lt err gt Test AT MHUP MHUP Show list of supported lt cause gt s 1 16 17 18 27 31 0 7 and list of supported lt call_id gt s OK The following table shows the MHUP parameters lt Parameter gt Description lt cause gt 1 Cause description send to the NW in the disconnect message Unassigned unallocated number H3 Family AT Commands User Manual Page 80 of 375 FIDCCON 16 Normal call clearing 17 User busy 18 No user responding 27 Destination out of order 31 Normal unspecified lt call_id gt Index of the call id same as lt idx gt in CLCC command O All calls default 1 7 Specific call id Example AT MHUP MHUP 1 16 17 18 27 31 0 7 OK AT MHUP 16 3 Hung up call 3 and send cause Normal call clearing OK NO CARRIER AT MHUP 17 Hung up all calls and send cause User busy OK NO CARRIER AT MHUP 17 0 Hung up all calls and send cause User busy OK NO CARRIER 5 4 Call Status Messages 5 4 1 C
18. connected and there is no charge for being connected only per real data transferred 12 2 GPRS Commands This section defines commands that a terminal may use to control a GPRS ME GPRS MTs vary widely in functionality A class A ME might support multiple PDP types as well as circuit switched data and use multiple external networks QoS profiles At the other extreme a class C ME might support only a single PDP type using a single external network and rely on the HLR to contain the PDP context definition A comprehensive set of GPRS specific commands is defined below to provide the flexibility needed by the more complex ME The commands are designed to be expandable to accommodate new PDP types and interface protocols merely by defining new values for many of the parameters Multiple contexts may be activated if the interface link layer protocol is able to support them The commands use the extended information and error message capabilities described in this specification For MTs of intermediate complexity most commands have simplified forms where certain parameters may be omitted For the simplest MTs and for backwards compatibility with existing communications software it is possible to control access to the GPRS using existing modem compatible commands This modem compatible mode of operation is described below FHiIDCCON 12 2 1 CGCLASS GPRS Mobile Station Class This command is used to set the H3xx to operate according to the s
19. ACK indication 1 Broken protocol stack 2 Connection closed automatically due to non fatal alert lt number_of_acknowledged_bytes gt Total number of bytes that were acknowledged Example MIPSTAT 1 2 13 13 MIPCONF Configure Internal TCP IP stack This command allows configuring TCP stack parameters such as retransmissions number upper and bottom limits of retransmission timeout close delay It can be used to configure TCP socket parameters before socket activation Configuration values will be stored in H3xx module until power cycle This command must be use after MIPCALL is executed Command Syntax Response Action Remarks Set AT MIPCONF lt socket_ID gt OK The Set command lt retr_num gt lt min_TO gt lt ma ae updates TCP stack x_TO gt lt max_close_delay gt configuration H3 Family AT Commands User Manual Page 328 of 375 FIDCCON lt is_nack_ind_req gt CME ERROR lt err gt parameters Read MIPCONF MIPCONF The read command 1 lt retr_num gt lt min_TO gt lt m_ returns current ax_TO gt lt max_close_delay gt settings of TCP stack lt is_nack_ind_req gt lt CR gt lt LF parameters gt MIPCONF 2 lt retr_num gt lt min_TO gt lt m ax_TO gt lt max_close_delay gt lt is_nack_ind_req gt lt CR gt lt LF gt MIPCONF 3 lt retr_num gt lt min_TO gt lt m ax_TO gt lt max_close_delay gt lt i
20. Command Syntax Response Action Remarks Set FTPSTAT lt file OK FTPSTAT Parameter is optional can be a directory lt result gt lt status gt or file name or a file path name The name gt ERROR lt error_code gt command execution result return to the user as an unsolicited response 0 operation fails 1 operation success 2 data follows Read FTPSTAT ERROR Not supported Test FTPSTAT FTPSTAT Return command format lt file directory name gt OK The following table shows the FTPSTAT parameter lt Parameter gt Description File directory name A file name or a file path name string the max length is 255 octets H3 Family AT Commands User Manual Page 357 of 375 FIDCCON Example FTPLIST 1 AT FTPstat usr OK FTPSTAT 2 213 Status follows FTPSTAT 2 drwxr x x 5 ftp ftp FTPSTAT 2 213 End of status FTPSTAT 1 AT FTPstat OK FTPSTAT 2 211 FTP server status FTPSTAT 2 FTPSTAT 2 FTPSTAT 2 FTPSTAT 2 FTPSTAT 2 FTPSTAT 2 FTPSTAT 2 FTPSTAT 2 FTPSTAT 2 Connected to 221 179 37 21 Logged in as ftp TYPE ASCII No session bandwidth limit Control connection is plain text FTPSTAT 2 211 End of status FTPSTAT 1 14 14 FTPSYST Request Operating System Type 4096 Apr 22 2001 usr Session timeout in seconds is 120 Data connections will be plain text At session startup client cou
21. FIDCCON OK FTPOPEN 1 attftpclose OK FTPCLOSE 1 connection success close connection close connection fails AT FTPOPEN ftp23233 adobe com anonymous ftpuser adobe com Naunch a connection with a non existing server OK FTPOPEN 0 AT FTPOPEN FTPOPEN 0 open connection fails Query connection status return no connection 14 3 FTPCLOSE Close Established FTP Connection This command is used for closing the connection between the H3xx module and the FTP server it only takes effect when there is no data transmission or no FTP command executed DTR interruption can close FTP connection as well FTPCLOSE 1 close successful att ftpclose H3 Family AT Commands User Manual Command Syntax Response Action Remarks OK Command return FTPCLOSE 1 connection success Set FTPCLOSE lt connection_status gt 0 eornection tail Or ERROR lt error_code gt Read FTPCLOSE ERROR Not supported Test FTPCLOSE ERROR Not supported Example at ftpclose close connection OK Page 346 of 375 FIDCCON ERROR at cmee 2 OK attftpclose CME ERROR FTP session is inactive FTP is inactive close error 14 4 FTPINFO FTP Unsolicited Indication Enable Disable This command can enable or disable FTP unsolicited indication when it is enabled it will print the command send by FTP and data information returned by FTP Server This is only used for indentifying th
22. MAVOL volume level of all the features in the current active accessories lt accy gt lt feature1 gt vol gt MAVOL lt accy gt lt feature2 gt vol gt MAVOL lt accy gt lt feature4 gt vol gt MAVOL lt accy gt lt feature8 gt vol gt H3 Family AT Commands User Manual Page 248 of 375 FIDCCON OK Test MAVOL MAVOL supported accessories supported features combinations supported volume levels Test command returns the supported range of volume levels accessories and features The following table shows the MAVOL parameters lt Parameter gt Description lt accy gt 1 1st channel SPK SPK oe 2 2nd channel AUXO AUXO 3 1 and 2 6 lt feature gt 1 Voice et 2 Tone 3 1 and 2 4 Midi 5 1 and 4 6 2 and 4 7 1 and 2 and 4 lt vol gt Volume level 0 7 Example H3 Family AT Commands User Manual Page 249 of 375 FIDCCON AT MAVOL MAVOL 1 1 4 MAVOL 1 2 1 MAVOL 1 4 4 OK AT MAVOL MAVOL 1 3 1 7 0 7 OK AT MAVOL 1 7 3 OK AT MAVOL MAVOL 1 1 3 MAVOL 1 2 3 MAVOL 1 4 3 OK AT MAVOL 3 7 3 OK Modified all the features in the 1st channel Modified all the features within the 1st channel and 2nd channel 11 2 12 MATONE Start or stop the tone play This command can play tone and stop play Note For H350 xxx 10 this commands is not suppor
23. list of supported lt Delivery of erroneous SDUs gt s list of supported lt Transfer delay gt s list of supported lt Traffic handling priority gt s list of supported lt Source statistics descriptor gt s list of supported lt Signalling indication gt s lt CR gt lt LF gt CGEQMIN lt PDP_type gt list of supported lt Traffic class gt s list of supported lt Maximum bitrateUL gt s list of supported lt Maximum bitrate DL gt s list of supported lt Guaranteed bitrate UL gt s list of supported lt Guaranteed bitrate DL gt s list of supported lt Delivery order gt s list of supported ranges for each PDP type are returned on a separate line H3 Family AT Commands User Manual Page 281 of 375 FIDCCON lt Maximum SDU size gt s lisof supported lt SDU error ratio gt s list of supported lt Residual bit error ratio gt s list of supported lt Delivery of erroneous SDUs gt s list of supported lt Transfer delay gt s list of supported lt Traffic handling priority gt s list of supported lt Source statistics descriptor gt s list of supported lt Signalling indication gt s The following table shows the CGEQMIN parameters lt Parameter gt Description lt cid gt A numeric parameter which specifies a particular PDP context definition see CGDCONT and CGDSCONT commands lt Traffic class gt
24. lt aud_ret_code gt lt aud_ret_code gt integer value indicating the return code of the audio driver function call and may be 0 aud_rc_ok 1 aud_rc_resource_in_use 2 aud_rc_resource_conflict 3 aud_rc_handle_not_used 4 aud_rc_no_hw_support 5 aud_rc_sharing_ violation 6 aud_rc_parameter_out_of_range 7 aud_rc_audio_driver_disabled 8 aud_rc_missing dsp_resou rces 10 aud_rc_format_not_supported 11 aud_rc_no_playback H3 Family AT Commands User Manual Page 253 of 375 FIDCCON 12 aud_rc_unknown_position 13 aud_rc_request_error 14 aud_rc_syntax_error 15 aud_rc_tone_error 16 aud_rc_storage_problems 17 aud_rc_performance_problems 18 aud_rc_ram_buffer_used 19 aud_rc_suspend_resume_error 20 aud_rc_info 11 2 13 MMICG Microphone Gain Value This command handles the selection of microphone gain values of MIC The new value remains after power cycle Command Syntax Response Action Remarks Set MMICG lt gai OK The Set command sets the n gt r microphone gain value CME ERROR lt err gt Read MMICG MMICG lt gain gt The Read command displays the OK current microphone gain Test MMICG MMICG list of The Test command displays the list supported lt gain gt s of supported gain values OK The following table shows the MMICG parameters lt Parameter gt Description lt gain gt Microphone gain values 0 15 0 is
25. no connection Test FTPOPEN FTPOPEN lt destination_ip url gt Returns command lt username gt lt password gt format lt account gt range of supported port s range of supported port s range of supported port s OK The following table shows the FTPOPEN parameters lt Parameter gt Description destination_ip url IPor URL of remote FTP site The range of IP address is 0 255 IP address format XXX XXX XXX XXX URL format www XXX com string format the max length is 255 octets username Registered Username for FTP Server string the max length is 255 octets password Registered Password for FTP Server string the max length is 255 octets account User Account Some FTP server not only need username password but also need account input this information if it is required String the max length is 255 octets source_control_port Port for FTP control connection on source side the default vaule is 20 Range 0 65535 destination_control_port Port for FTP control connection on remote side Range 0 65535 source_data_port Port for FTP data connection on source side the default value is 21 Range 0 65535 Example at MIPCALL 1 UNINET create a wireless connection OK MIPCALL 10 209 215 129 AT FTPOPEN ftp adobe com anonymous ftpuser adobe com open FTP connection H3 Family AT Commands User Manual Page 345 of 375
26. plolle Lo 1 Breen eee nee eer eenren er etre ee eee ee eee ee aap E S e 61 5 3 9 CCWA Call Waiting COMMANGL ccc cccccccccccessescesceecsecseesecseesecsesscssesecseeseesseseesessceacsecacseeseeseeas 63 5 3 10 HCCWA INdiCation oo eeeeeceeceeseeeseseseseeeeeeseeesesceessesescsceacscneseeaeacsesssscacaesesseecaceeeeeeeeaeeeeeeeeraeeeeetees 64 5 3 11 CHLD Call Related Supplementary Services COMMANGA ccceccesssscssceesecsseseeeceseeeeeeees 66 5 3 12 CCFC Call Forwarding Number and Conditions ccccccccccsscsscsecsscseesecsesseeecsecsecseeseeaes 69 5 3 13 CLIR Calling Line Identification REStriction cc ccc ccesscscsscescseceecsecscsecsessccseseesseseeeesees 72 5 3 14 CBST Select Bearer Service Type ce cccccccsccsccsesscssesecssescesesecescsecsecsecsecsecsecsceceecsseeecseensesees 74 5 3 15 O Return to Online Data Stal sa rscanscetvesrarantuctstrnetaracssecetaravanscaneyecararettoesainanctsinimeaniaenramanannie 77 5 3 16 CHUP Hang Up Callan ccc cccccccccscssesscssesecssssccsesecsscsecsecsecsececsscsecsecsecsecsessecseseceaesecsaeseeneeaceas 78 H3 Family AT Commands User Manual Page 6 of 375 FIDCCON 5 3 17 MDC Selection of Desired Message to Be Displayed Upon Connection of a Voice Call 79 9 39 18 MAUP Foxx ung UP callv Siccin cisenivdenurextvecuesddeanesstvcauiele ueduaseestosstiatacnseineteeiiaes 80 5A Call Status MESSAGES s s sescssccdctcsszeigoss cenvestacesersevacds cuss setandensecesiosssat
27. 19 24 08 0 H3 Family AT Commands User Manual Page 137 of 375 FIDCCON AT CNMA OK AT CNMI CNMI 1 0 0 1 0 OK 7 1 9 CMTI Unsolicited Response New SMS DELIVER Receipt Indication The CMTI unsolicited response is sent to the TE upon receipt of anew SMS DELIVER SMS if the CNMI parameter lt mt gt is set to 1 Refer to CNMI New Message Indications to Terminal This unsolicited message indicates that anew SMS DELIVER message was received and is stored in location lt index gt CMTI lt mem gt lt index gt The following table shows the CMTI parameters lt Parameter gt Description lt mem gt Message memory space SM SIM memory storage lt index gt Location of the new message Example AT CNMI 2 1 OK AT CMGS 18 send to my self gt 079179521201009511000c917952428650290004AA0441 424344 CMGS 69 OK CMTI SM 4 7 1 10 CMT Unsolicited Response New SMS DELIVER Receipt The CMT unsolicited response is sent to the TE upon receipt of anew SMS DELIVER SMS if the CNMI parameter lt mt gt is set to 2 Refer to tCNMI New Message Indications to Terminal This unsolicited message displays the received SMS DELIVER message H3 Family AT Commands User Manual Page 138 of 375 FIDCCON In text mode CMGF 1 CMT lt oa gt lt alpha gt lt scts gt lt tooa gt lt fo gt lt pid gt lt dcs gt lt sca gt lt tosca gt lt length
28. 2 PLMN is present on the Operator Controlled PLMN List Example AT COPS COPS 2 CHN UNICOM UNICOM 46001 2 2 CHN UNICOM UNICOM 46001 0 3 CHIN A MOBILE CMCC 46000 0 OK AT COPS COPS 1 0 CHN UNICOM 2 OK AT COPS 2 OK AT CREG 2 OK CREG 3 AT COPS 4 2 46001 CREG 3 CREG 2 CREG 1 27A0 0DEB OK AT COPS COPS 1 2 46001 2 OK H3 Family AT Commands User Manual Page 185 of 375 FIDCCON 9 1 6 CPOL Preferred Operators This command is used to edit the PLMN selector lists in the SIM card or active application in the UICC GSM or USIM If no list has been previously selected the EFPLMNwAcT user controlled PLMN selector with Access Technology list is the one accessed by default lt index1 gt lt format gt lt op er1 gt lt GSM_AcT1 gt lt GSM_ Compact_AcT1 gt lt UTR AN_AcT1 gt lt CR gt lt LF gt CPOL lt index2 gt lt format gt lt op er2 gt lt GSM_AcT2 gt lt GSM_ Compact_AcT2 gt lt UTR AN_AcT2 gt OK Command Syntax Response Action Remarks Set AT CPOL OK or lt index gt CME ERROR lt err gt Note In case the index already lt format gt exists in the list the new entry will lt oper gt lt erase the old one and replace it in GSM_AcT the list gt lt GSM_ Compact_ The H3xx may also update this AcT gt lt UT list automatically when new RAN AcT net
29. AT CPIN lt correct PIN gt OK AT CPIN CPIN READY OK The status of the SIM is still enabled but the PIN is READY for this session The SIM is enabled per session After power up SIM must be unlocked again by using the CLCK command The following case shows an example of three unsuccessful attempts at entering the PIN AT CPIN CPIN SIM PIN OK AT CPIN lt wrong pin gt CME ERROR incorrect password AT CPIN lt wrong pin gt CME ERROR incorrect password AT CPIN lt wrong pin gt CME ERROR SIM PUK required AT CPIN CPIN SIM PUK IPIN is blocked The PUK is needed for unblocking OK AT CPIN lt PUK gt lt NEW PIN gt Enter PUK and new PIN OK AT CLCK FD 1 lt wrong PIN2 gt CME ERROR incorrect password AT CLCK FD 1 lt wrong PIN2 gt CME ERROR incorrect password AT CLCK FD 1 lt wrong PIN2 gt CME ERROR SIM PUK2 required AT CPIN CPIN SIM PUK2 IPIN2 is blocked The PUK2 is needed for unlocking H3 Family AT Commands User Manual Page 167 of 375 Bs FIBOCOM OK AT CPIN lt PUK2 gt lt NEW PIN2 gt OK Enter PUK2 and new PIN2 8 1 4 TPIN Query Number of Remaining SIM PIN PUK Entering Attempts This command returns the number of remaining attempts of entering the PIN and PUK for the SIM card in use The command returns the number of remaining attempts for PIN1 CHV1 PIN2 CHV2 PUK1 unblock CHV1 and PUK2 unblock CHV2 Number of av
30. AT CSCA CSCA AC 129 OK AT CMGW gt 0011640A8150224902450000A700 CMGW 16 OK AT CMGR 16 CMGR 2 13 0481 CAEDFB11640A8150224902450000A700 SCA is ACDEB in pdu mapped to ABC OK AT CMGW 13 gt 0381AB1211640A8150224902450000A700 Set SCA to BA21 CMGW 17 OK AT CMGR 17 CMGR 2 13 0381AB1211640A8150224902450000A700 II SCA is set correctly only for current SMS but CSCA setting didn t changed OK AT CSCA CSCA AC 129 SCAdidn t change in storage OK H3 Family AT Commands User Manual Page 127 of 375 FiIDCCON 7 1 5 CSMP Set Text Mode Parameters This command is a basic command and is used to select values for additional parameters needed when SMS is sent to the network or placed in storage when TEXT mode is selected Comman d Syntax Response Action Remarks Set CSMP lt fo OK The set command selects values for gt lt vp gt lt pid an additional parameters needed when SMS is gt lt dcs gt sent to the network or placed in storage CMS ERROR when text format message mode is lt err gt selected Read AT CSMP CSMP The read command returns the current lt fo gt lt vp gt lt pid gt lt dc parameters value s gt OK Test AT CSMP The test command just returns OK OK The following table shows the CSMP parameters lt Parameter gt Description lt fo gt First octet of GSM 03 40 Integer format For details see CMGW definiti
31. AT MIPOPEN Terminal checking the free sockets MIPOPEN 3 4 OK AT MIPOPEN 1 0 WWW GOOGLE COM 80 0 TCP OK MIPOPEN 1 1 AT MIPOPEN 2 0 www google com 80 1 UDP OK MIPOPEN 2 1 Listen socket over TCP AT MIPOPEN 1 1100 0 0 0 0 0 0 Listens to any port at any IP OK MIPOPEN 1 1 122 221 32 64 1200 II Remote side connected to the listen socket AT MIPOPEN 3 3212 122 1 222 134 0 0 Listen to any port at specific IP OK MIPOPEN 3 1 122 1 222 134 1222 OK Remote side connected to the listen socket 13 3 MIPCLOSE Close a Socket This command causes the H3xx to free the socket accumulating buffer and to close the socket Note All data stored in the accumulating buffer will be lost Command Syntax Response Action Set MIPCLOSE lt Soc OK ket_ID gt lt Mode gt MIPCLOSE lt Socket_ID gt lt number_of_acknowledged_bytes gt lt close_ type gt or ERROR Read MIPCLOSE MIPCLOSE lt socket_ID gt H3 Family AT Commands User Manual Page 312 of 375 FIDCCON OK for all ACTIVE sockets or MIPCLOSE 0 OK if no active sockets Test MIPCLOSE MIPCLOSE 1 4 0 2 OK The following table shows the MIPCLOSE parameters lt Parameter gt Description lt Socket_ID gt Unique number that identifies a connection Valid socket numbers 1 2 3 and 4 lt Mode gt This value only used for TCP connectio
32. CGEQMIN 3G Quality of Service Profile Minimum acceptable This command allows the TE to specify a minimum acceptable profile which is checked by the MT against thenegotiated profile returned in the Activate Modify PDP Context Accept message Command Syntax Response Action Remarks Set AT CGEQMIN lt cid gt OK Set command specifies a lt Traffic class gt Or profile for the context lt Maximum identified by the local CME ERROR lt error gt fot Wentificat bitrate UL gt lt Maximum COMSKI IGE MMCANON bitrate DL gt parameter lt cid gt The lt Guaranteed specified profile will be stored in the MT and bitrate UL gt checked against the lt Guaranteed bitrate i negotiated profile only at DL gt lt Delivery ER Pre activation or MS initiated order gt lt Maximum SDU modification of the related size gt lt SDU error ratio gt context lt Residual bit error ratio gt lt Delivery of erroneous SDUs gt lt Transfer delay gt lt Traffic handling priority gt lt Source statistics descriptor gt lt Signalling indication gt NNIINI Read AT CGEQMIN CGEQMIN lt cid gt lt Traffic The read command returns class gt lt Maximum bitrate the current settings for H3 Family AT Commands User Manual Page 279 of 375 FIDCCON UL gt lt Maximum bitrate DL gt lt Guaranteed bitrate UL gt lt Guaranteed bitrate DL gt lt Delivery order gt lt Maximum
33. CMGW 132 OK AT CMGR 132 H3 Family AT Commands User Manual Page 155 of 375 FIDCCON CMGR 2 14 07917952140230F212000000000C9179524286502900 OK AT CMGF 1 OK AT CMGR 132 CMGR STO UNSENT 18 0 0 0 972524680592 145 0 OK 7 1 18 CMGD Delete Message This command handles deletion of a single message from memory location lt index gt or multiple messages according to lt delflag gt If the optional parameter lt delflag gt is entered and is greater than 0 the lt index gt parameter is practically ignored If deletion fails result code CMS ERROR lt err gt is returned Note The deletion of multiple commands is a time consuming process that may require more than 60 seconds to complete valid lt index gt s list of valid lt deflag gt s Command Syntax Response Action Remarks Set CMGD lt inde OK x gt lt delflag gt or CMS ERROR lt err gt Read The Read command for CMGD is not defined by ETSI and therefore is not supported by the H3xx The H3xx returns an error Test CMGD CMGD list of The Test command displays the supported values of lt index gt it list the index where have stored the SMS The following table shows the CMGD parameters lt Parameter gt Description lt index gt 1 352 Index in the SMS memory of the message to be deleted lt delflag gt 0 Deletes the message specified in lt index gt H3 Family AT Comm
34. H3 Family AT Commands User Manual Page 194 of 375 FIDCCON Read MCELL OK The Read command just returns OK and does nothing Test MCELL MCELL list of The Test command returns the supported lt mode gt s list possible lt mode gt amp lt screen_num gt of supported values lt screen_num gt s OK The following table shows the MCELL parameters lt Parameter gt Description lt mode gt 0 One shot requested lt screen_num gt The requested screen number An integer number 1 2 10 11 12 13 14 15 16 Serving Idle Information screen Circuit Switched Serving Cell Information screen Miscellaneous Information screen Uplink Data Transfer screen Downlink Data Transfer screen Neighbor 1 Cell Information screen Neighbor 2 Cell Information screen Neighbor 3 Cell Information screen Neighbor 4 Cell Information screen Neighbor 5 Cell Information screen Neighbor 6 Cell Information screen Neighbor Cells Summary screen Re selection screen Hopping Information screen PDP1 Context Information screen PDP2 Context Information screen H3 Family AT Commands User Manual Page 195 of 375 FIDCCON 17 PDP3 Context Information screen 18 PDP4 Context Information screen 19 Serving Cell paging parameters 20 Optional SYSINFOs MCELL Indication After AT MCELL command the information about the Cellular Network will return bac
35. New Message Acknowledgment This command acknowlegde the receipt of a CMT and CDS response from the terminal to the H3xx A CMT response receipt confirms the correct reception of anew SMS DELIVER message which was routed directly to the terminal A CDS response receipt confirms the correct reception of a new SMS STATUS REPORT message which was routed directly to the terminal When the H3xx sends a CDS response to the terminal it waits a predefined timeout of 15 seconds for the CNMA acknowledgment The H3xx will not send another CDS result code to the terminal before the previous one is acknowledged or the timeout expires H3 Family AT Commands User Manual Page 135 of 375 FIDCCON When the H3xx sends a CMT response to the terminal it waits a predefined timeout of 15 seconds for the CNMA acknowledgment The H3xx will not send another CMT result code to the terminal before the previous one is acknowledged or the timeout expires Upon receipt of the CNMA command the H3xx sends RP ACK to the network The acknowledged SMS will not be saved in message storage If the command is executed but no acknowledgment is expected or some other H3xx related error occurs the final result code CMS ERROR lt err gt is returned Note AT CNMA send acknowledgment to nework Two conditions must be met AT CSMS 1 command set lt service gt to 1 AT CNMI 2 command set lt mt gt to 2 or AT CNMI 1 command set lt ds gt to 1 After the two c
36. OK AT MAI2SY MAI2SY 0 0 0 0 OK AT MAI2SY MAIZ2SY 0 1 0 1 0 1 2 3 4 0 1 2 OK Note AT MAIDIGITAL set to 0 MAI2SY is invalid The setting is invalid when calling H3 Family AT Commands User Manual Page 259 of 375 FIDCCON 12 GPRS 12 1 GPRS Functionality GSM 07 07 defines commands that a TE may use to control a GPRS ME via a non multiplexed character stream interface This places certain limitations on the functionality of the interface For example it is not possible for the ME to send control information to the TE or for the TE to send commands to the ME whilst the interface is in the online data state unless the layer 2 protocol itself supports this feature GSM 07 60 12 However H3xx specific escape mechanism DTR is provided to enable the TE to switch the H3xx into limited online command state The use of a multiplexed interface GSM 07 10 is not considered here See Multiplexer Feature The H3xx specific escape mechanism use DTR as an escape signal following amp D parameters and designed for limited non network related commands This specific mechanism purpose is to give the user a way to retrieve the signal strength The time limit of consecutive DTR toggles is a minimum of 90 seconds The H3xx specific is not designed to support online command and data states both at the same time therefore any wrong or extreme usage can cause unexpected behaviors The basic GPRS concept is be always
37. OK AT MSDNS read when MIPCALL is disconnected MSDNS 1 0 0 0 0 0 0 0 0 MSDNS 2 0 0 0 0 0 0 0 0 MSDNS 3 0 0 0 0 0 0 0 0 MSDNS 4 0 0 0 0 0 0 0 0 MSDNS 5 0 0 0 0 0 0 0 0 OK H3 Family AT Commands User Manual Page 339 of 375 FIDCCON AT MSDNS 2 212 150 49 10 206 49 94 234 set socket 2 prim amp sec DNS OK AT MSDNS 4 62 120 55 10 set socket 4 prim DNS only OK AT MSDNS 5 212 150 49 10 206 49 94 234 set socket 5 prim amp sec DNS OK AT MSDNS read when MIPCALL is disconnected MSDNS 1 0 0 0 0 0 0 0 0 MSDNS 2 212 150 49 10 206 49 94 234 MSDNS 3 0 0 0 0 0 0 0 0 MSDNS 4 62 120 55 10 0 0 0 0 MSDNS 5 212 150 49 10 206 49 94 234 OK 13 17 MIPODM Open a Socket UDP or TCP in Online Data Mode This command causes the H3xx to initialize a new socket that waits for a connection from a remote machine or opens a common or TCP connection with a remote side according to received parameters and switch it to Online raw data transfer Data Mode and open a connection with a remote side Notes Online Data Mode allows the user to transfer raw data from terminal to Network and vice versa over a GPRS channel Currently only RS232 connection to terminal with hardware flow control is supported Each socket allocates two accumulating buffers 8192 bytes for sending and 16384 bytes for receiving When the user sends amount of data less than buffer size th
38. Page 222 of 375 FIDCCON The following table shows the MSMPD parameters lt Parameter gt Description lt status gt 0 Disable the SIM card hot plug feature 1 Enable the SIM card hot plug feature The default value is 0 Note For H350 the default value is 1 10 2 9 GPIO Set and Read GPIO This command intends to configure supported GPIO pins and gets value from input pin H3xx support 11 GPIO pins H350 doesn t support this command currently All these pins can be set to output and input mode The default configuration is input but it s better to set direction before use The high voltage level is 1 8V Note For H350 H380 this command is not supported Command Syntax Response Action Remarks Set AT GPIO lt pin gt OK Used to set direction lt direct gt lt value gt Or and output value CME ERROR lt err gt Read AT GPIO GPIO Return all the pin state lt pin gt lt direct gt lt value gt here OK Or ERROR Test AT GPIO TOPO Apina dlacie valle Return supported values OK or ERROR H3 Family AT Commands User Manual Page 223 of 375 FIDCCON The following table shows the GPIO parameters lt Parameter gt Description lt pin gt 23 52 53 73 74 75 76 89 106 107 108 The value is pin number on module lt direct gt 0 Input 1 Output 2 Query output value of the single pin lt value gt 0 Low level 1 High leve
39. This command allows the automatically selected band switch to the bands in the following list at most four bands UMTS_BAND 1 2100 MHz UMTS_BAND Il 1900 MHz UMTS_BAND V 850 MHz UMTS_BAND_ VIII 900 MHz Note For H350 xxx 10 H380 this commands is not supported Command Syntax Response Action Set AT CUBAND lt band_ OK 1 gt lt band_2 gt lt band or _3 gt lt band_4 gt CME ERROR lt err gt Read AT CUBAND CUBAND lt band_1 gt lt band_2 gt lt band_3 gt lt band_4 gt OK Test AT CUBAND CUBAND list of supported bands OK The following table shows the CUBAND parameters lt Parameter gt Description lt band_1 gt or 0 Automatic band selection pand Aor UMTS2100 Selection of UMTS_BAND_I 2100MHz band lt band_3 gt or UMTS1900 Selection of UMTS_BAND_II 1900MHz band lt band_4 gt UMTS850 Selection of UMTS_BAND_V 850MHz band UMTS900 Selection of UMTS_BAND_ VIII 900MHz band H3 Family AT Commands User Manual Page 191 of 375 FIDCCON Note For registering 3G network only Example AT CUBAND CUBAND UMTS2100 UMTS1900 UMTS850 UMTS900 OK AT CUBAND CUBAND 0 UMTS2100 UMTS1900 UMTS850 UMTS900 OK AT CUBAND UMTS2100 OK AT CUBAND CUBAND UMTS2100 OK 9 1 9 XREG Current Network Registration
40. delivered to UMTS up link traffic at a SAP As an example a bitrate of 32 kbit s would be specified as 32 e g AT CGEQREQ 32 This parameter should be provided if the Traffic class is specified as conversational or streaming refer 3GPP TS 24 008 subclause 10 5 6 5 lt Maximum bitrate DL gt A numeric parameter that indicates the maximum number of kbits s delivered by UMTS down link traffic ata SAP As an example a bitrate of 32 kbit s would be specified as 32 e g AT CGEQREQ 32 If the parameter is set to 0 the subscribed value will be requested This H3 Family AT Commands User Manual Page 288 of 375 FIDCCON parameter should be provided if the Traffic class is specified as conversational or streaming refer 3GPP TS 24 008 subclause 10 5 6 5 lt Guaranteed bitrate UL gt A numeric parameter that indicates the guaranteed number of kbits s delivered to UMTS up link traffic at a SAP provided that there is data to deliver As an example a bitrate of 32kbit s would be specified as 32 e g AT CGEQREQ 32 If the parameter is set to 0 the subscribed value will be requested This parameter should be provided if the Traffic class is specified as conversational or streaming refer 3GPP TS 24 008 subclause 10 5 6 5 lt Guaranteed bitrate DL gt A numeric parameter that indicates the guaranteed number of kbits s delivered by UMTS down lin
41. is given a voice call is originated to the last dialed number If the semicolon is not given a Data call is originated Note The last dialed call type is irrelevant to the DL command Note When ATDL is issued after a dialed number with comma digit e ATDL Voice dials the exact number that was last dialed including the DTMF tones sent e If ATDLis sent before any Dial command was issued mainly after Power On when the last number is an empty field the H3xx will return NO CARRIER as mentioned in the ITU V 25 ter standard CCFC 21 CCWA C 43 CLIP 30 CLIR 31 COLP 76 will be treat as call number and dail it again Example atdl ATDL 035658278 OK OK IVOICE call H3 Family AT Commands User Manual Page 54 of 375 FHiIDCCON 5 3 4 H Hang up Call This command hangs up a call The H3xx terminates the call whether it is a data or voice call and whether it is an incoming originating waiting or connected call ANO CARRIER message is returned to the terminal after the regular OK approval Note e To terminate hang up a MO data call while call is placed Any character sent from the terminal to the H3xx causes the Data call termination and NO CARRIER is sent from the H3xx to the terminal e To terminate a held Voice call or to terminate a call out of a MTPY call refer to CHLD Call Related Supplementary Services Command The following table shows the call state
42. operation success 2 connected already start to download data data follows is the downloaded data Read FTPRETR ERROR Not supported Test FTPRETR FTPRETR lt file Return command format name gt 0 1 0O OxFFFFFFFE OK The following table shows the FTPRETR parameters lt Parameter gt Description File name A file name or a file path name string the max length is 255 octets File type File type ASCII or Binary numeric in the range of O 1 0 ASCII 1 Binary Offset Strat upload offset address range 0 OxFFFFFFFE Example AT FTPRETR 123 TXT OK FTPRETR 2 II start to download transmit data data follows are the downloaded contents love you love you FTPRETR 1 download successfully AT FTPRETR 123 TXT 0 4 start to download from the No 4 character of the offset address OK FTPRETR 2 II start to download tanmismit data data follows are the downloaded contents love you love you FTPRETR 1 download successfully H3 Family AT Commands User Manual Page 362 of 375 FIDCCON 14 18 FTPGET Enter the File Download Mode By executing this command the program will start data connection process download the speicifed file data from the server and stay in this command mode all the time When the data downloading is completed or the buffer is full in the module it will exit from this mode In this command mode if only respon
43. 1372 OK MIPXOFF 2 AT MIPSEND 2 474554202F20485454502F312E300D0A486F 73743A207777772E6 6F6F6 6C6 H3 Family AT Commands User Manual Page 330 of 375 FIDCCON 52E636 F6DODOAODOA MIPSEND 2 1 1372 OK MIPSTAT 2 0 30 MIPXON 2 MIPSTAT 2 0 40 MIPRTCP 2 930 485454502F312E312033303220466F 756E640D0A4C6F6361 74696F6E3A206874 74703A2F2F7777772E6 76F6F6 76C652E636F 2E696C2F63786665723F633D505245462533443A5 44D25334 43131313935 MIPRTCP 2 450 31343833323A5325334467384A637631426A5458472D30636A5926707265763D 2FO0D0A5365742D436F6F6B69653A20505245463D49443D3639303762623837353138626632333 73A43523D 313A544D3D MIPRTCP 2 370 313131393531343833323A4C4D3D313131393531343833323A533D644F 656476 7A6C34765F7059475A384A3B20657870697265733D53756E2C2031372D4A616E2D3230333820 31393A31 343A30372047 MIPRTCP 2 290 4D543B20706174683D2F3B20646F6D6 1696E3D2E676F6F676C652E636FEDOD0A4 36F6E 74656E74 2D547970653A20746578742F68746D6C0D0A5365727665723A204757532F322E310D0A436F6E 74656E MIPRTCP 2 210 742D4C656E6774683A203231370D0A4461 74653A205468752C203233204A756E20323030 352030383 MIPRTCP 2 130 48454 1443E3C5449544C453E333032204D6F 76656430 2F5449544C453E3C2F 48454 1443 E3C424F44 593E0A3C48313E333032204D6F 7665643C2F 483 13E0A54686520646F63756D656E 74206861732 06D MIPRTCP 2 50 6F7665640A3C4120485245463D22687474703A2F2F7777772E676F6F676C652E636F 2E696 C2F63786 H3 Family AT Commands User Manual Page 331 of 375 FID
44. 4 IP CMNET 0 0 0 0 0 0 CGDCONT 6 PV6 CDOE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 OK AT CGCMOD 1 1 OK AT CGCMOD 1 1 6 OK AT CGDCONT CGDCONT 1 IP CMNET 172 29 107 202 0 0 CGDCONT 2 IP 0 0 0 0 1 1 CGDCONT 3 IP CMNET 0 0 0 0 0 0 CGDCONT 4 IP CMNET 0 0 0 0 0 0 CGDCONT 6 PV6 CDOE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 OK AT CGCMOD CGCMOD 1 2 3 4 6 OK 12 2 15 CGDATA Enter Data State This execution command causes the MT to perform whatever actions are necessary to establish communication between the TE and the network using one or more GPRS PDP types This may include performing a GPRS attach and one or more PDP context activations If the parameters are accepted MT displays the intermediate result code CONNECT on TE and enters the online data state thereafter data transfer may proceed No other commands following CGDATA in the command line will be processed H3 Family AT Commands User Manual Page 295 of 375 FIDCCON Command Syntax Response Action Remarks Set CGDATA CONNECT Set command specifies the lt L2P gt lt L2P gt lt cid gt it follows data transfer and lt cid gt to establish data call csd lt cid gt connection state or CME ERROR lt error gt Test CGDATA CGDATA list of supported Test command returns values lt L2P gt s supported as a compound value OK The following table shows the CGDATA p
45. 5E3 e g AT CGEQREQz 5E3 OEO means subscribed value refer 3GPP TS 24 008 subclause 10 5 6 5 lt Delivery of erroneous SDUs gt a numeric parameter that indicates whether SDUs detected as erroneous shall be delivered or not 0 no 1 yes 2 no detect 3 subscribed value Other values are reserved lt Transfer delay gt a numeric parameter 0 1 2 that indicates the targeted time between request to transfer an SDU at one SAP to its delivery at the other SAP in milliseconds If the parameter is set to 0 the subscribed value will be requested refer 3GPP TS 24 008 subclause 10 5 6 5 lt Traffic handling priority gt a numeric parameter 1 2 3 that specifies the relative importance for handling ofall SDUs belonging to the UMTS bearer compared to the SDUs of other bearers If the parameter is set to 0 thesubscribed value will be requested refer 3GPP TS 24 008 subclause 10 5 6 5 lt Source Statistics Descriptor gt Supported in R7 P S anumeric parameter that specifies characteristics of the source of the submitted SDUs for a PDP context This parameter should be provided if the Traffic class is specified as conversational or streaming refer 3GPP TS 24 008 subclause 10 5 6 5 0 Characteristics of SDUs is unknown default value 1 Characteristics of SDUs corresponds to a speech source Other values are reserved lt Signalling Indication gt
46. AT MIPODM MIPODM list of supported The following table shows the MIPODM parameters lt Parameter gt Description Socket_ID Valid socket numbers 1 2 3 and 4 A unique number that identifies a connection H3 Family AT Commands User Manual Page 341 of 375 FIDCCON Source Port Port of source site Port range 1 65535 decimal digits Remote IP IP of the remote site in the form t AAA BBB CCC DD The range of each octet is 0 255 The value can be written in 1 2 or 3 digits Host name of remote site The host name convention should meet the rules as describe in RFC 1035 section 2 3 Conventions Syntax is not validated except the maximum length 255 characters Remote Port Port of remote site Port range 1 65535 decimal digits for outgoing connection Port 0 for incoming connection Protocol Type of protocol stack 0 1 State 0 1 Note It s recommended not to use port numbers below 1024 those numbers are reserved for OS use Example Opening socket 1 in Online Data Mode using TCP protocol from port 1104 designation IP 123 245 213 012 designation port 1124 AT MIPODM 1 172 90 237 21 1124 0 OK MIPODM 1 1 Enter invalid command format AT MIPODM ERROR Check opened in Online Data Mode socket state when H3xx is pseudo command mode AT MIPODM MIPODM 1 1 OK Listen socket over TCP H3 Family AT Commands User Manual Page 342 of 375
47. Active 1 Held 2 Dialing MO call 3 Alerting MO call 4 Incoming MT call 5 Waiting MT call 6 Released lt mode gt Bearer Teleservice 0 Voice Call 1 Data lt mpty gt Multiparty status O Call is not part of a multiparty call 1 Call is one of multiparty call parties lt number gt Phone number in the format specified by lt type gt Contains a string of up to 32 characters lt type gt Phone number display format Type of address octet in integer format refer to GSM 04 08 subclause H3 Family AT Commands User Manual Page 84 of 375 FIDCCON 10 5 4 7 129 Local number 145 International number with access character Note When a mobile originated call is routed to PSTN PABX no ALERT indication is prompted Example AT CLCC CLCC 0 1 OK AT CLCC CLCC 1 0 0 0 0 01256316830 129 OK AT CLCC CLCC 0 OK AT CLCC 1 Example with unsolicited indication OK ATD055490698 OK CLCC 1 0 2 0 0 055490698 129 CLCC 1 0 3 0 0 055490698 129 OK CLCC 1 0 0 0 0 055490698 129 ATH NO CARRIER OK CLCC 1 0 6 0 0 055490698 129 H3 Family AT Commands User Manual Page 85 of 375 FHiIDCCON 5 4 3 MCST Call Status Messages This command displays the current state of the call processing and also enables disables the unsolicited indication of any change in the call processing state Note For H350 xxx 10 H380 this command is
48. Bits 3210 0000 Unknown 0001 ISDN telephone numbering plan E 164 E 163 0011 Data numbering plan X 121 0 100 Telex numbering plan 1 000 National numbering plan 1001 Private numbering plan 10 10 ERMES numbering plan ETSI DE PS 3 01 3 111 1 Reserved for extension All other values are reserved H3 Family AT Commands User Manual Page 125 of 375 FIDCCON CSCA lt SCA gt parameters Following table describes CSCA lt SCA gt valid parameters including the conversion when using stored lt SCA gt in SMS PDU mode editing SMS via CMGW or CMGS without SCA This is according to 24 008V031000P Table 10 5 118 GSM 24 008V031000P Called party BCD number CSCA 97212356 145 OK AT CSCA 97212356 OK AT CSCA CSCA 97212356 129 OK AT CSCA CSCA AC 129 OK AT CMGW 13 H3 Family AT Commands User Manual lt SCA gt Character in SMS Text mode Mapped character for SMS PDU mode Digits 0 9 Digits 0 9 H 0x91 w aN m p aN Toi B D Toi P Example AT CSCA Read SCA address and TOSCA stored in SIM EF smsp Page 126 of 375 FIDCCON gt 0481ABCD1211640A8150224902450000A700_ gt A A gt B B gt C gt D CMGW 15 OK AT CMGR 15 CMGR 2 13 0481ABCD1211640A8150224902450000A700 I SCA read as stored for current SMS OK AT CSCA CSCA AC 129 Read command remained SCA settings didn t change OK
49. CGDCONT Define PDP Context Note that CC is a not supported value This command specifies the PDP Packet Data Protocol context This command allows specifying specific PDP context parameter values for a PDP context identified by the local context identification parameter lt cid gt If the command is used only with the one parameter lt cid gt it means that the corresponding PDP context becomes undefined Command Syntax Response Action Remarks Set AT CGDCONT _ OK The Set command specifies the lt cid gt Ge context identification parameter lt PDP_type gt values for a PDP context A CME ERROR lt err gt lt APN gt special form of the Set lt PDP_addr gt command CGDCONT lt cid gt lt eleompe L causes the values for context sh eomp number lt cid gt to become Pete nell undefined pAN III Read AT CGDCONT CGDCONT lt cid gt The read command returns the lt PDP_type gt current settings for each defined lt APN gt lt PDP_addr gt context e compa It will be read only OK without ULC OMpe hep als laehe any set command AN OK Test AT CGDCONT CGDCONT range of The Test command returns the supported lt cid gt s values supported as a lt PDP_type gt list of compound value If the ME supported lt d_comp gt s supports several PDP types H3 Family AT Commands User Manual Page 262 of 375 FIDCCON list of supported lt
50. CSVM CSVM The Read command displays H3 Family AT Commands User Manual Page 116 of 375 FIDCCON lt mode gt lt number gt lt the currently selected voice mail type gt number and status enabled or OK disabled CSVM list of supported lt mode gt s The Test command displays the Test CSVM list of supported list of supported lt mode gt s and lt type gt s lt type gt s OK The following table shows the CSVM parameters lt Parameter gt Description lt mode gt 0 Disables the voice mail number default 1 Enables the voice mail number lt number gt Voice mail number in string String can be of up to 32 characters long starting with a digit r Other allowed characters are digits 0 9 and lt type gt Address octet type 129 ISDN telephony marketing plan national international number unknown 145 ISDN telephony numbering plan international number When the dialing string includes the international access code character the default is 145 Otherwise the default lt type gt is 129 Note If lt mode gt is set to 0 lt number gt and lt type gt are ignored If lt mode gt is set to 1 lt number gt is mandatory Example AT CSVM CSVM 0 1 129 145 OK AT CSVM 1 97255512356 145 OK AT CSVM CSVM 1 97255512356 145 OK H3 Family AT Commands User Manual Page 117 of 375 FIDCCON 6
51. Commands User Manual Page 60 of 375 FIDCCON lt n gt or the presentation of the CLI indication CME ERROR from the H3xx to the terminal lt err gt Note The Set command does not address the network Read AT CLIP CLIP lt n gt lt m gt The Read command returns the CLIP OK enable disable state in the H3xx as well as in the network provisioning state of the CLI presentation Test AT CLIP CLIP 0 1 The Test command returns the Set OK command options 0 1 5 3 8 CLIP Indication When the CLI presentation indication is enabled by the H3xx lt n gt 1 this unsolicited indication is sent to the terminal after the RING indication CLIP lt number gt lt type gt lt subaddr gt lt satype gt lt alpha gt lt CLI validity gt The following table shows the CLIP parameters lt Parameter gt Description lt n gt Enables disables the CLI presentation indication after the ring indication 0 Disable CLI presentation 1 Enable CLI presentation The default value is 0 lt m gt Shows the subscriber CLIP service status in the network 0 CLIP not provisioned 1 CLIP provisioned 2 Unknown for example no network and so on lt number gt Calling line number The number format is specified by lt type gt lt type gt Type of address octet in integer format 145 Default when the dialing string includes the international access H3 F
52. ERROR lt err gt CNMI lt mode gt lt mt gt lt bm gt lt ds gt lt bfr gt Read CNMI OK Test CNMI CNMI list of supported lt mode gt s list of supported lt mt gt s list of supported lt bm gt s list of supported lt ds gt s list of supported lt bfr gt s OK The following table shows the CNMI parameters lt Parameter gt Description 0 Buffer unsolicited result codes in the TA if the TA buffer is full the oldest indication may be discarded and replaced with the new received indications ring buffer 1 Discard indication and reject new received message unsolicited lt mode gt result codes when TA TE link is reserved otherwise forward them directly to the terminal 2 Buffer unsolicited result codes in the TA when the serial link is busy e g data transfer otherwise forward them directly to the terminal H3 Family AT Commands User Manual Page 132 of 375 FIDCCON No SMS DELIVER indications are routed to the terminal default If SMS DELIVER is stored in the H3xx the memory location indication is routed to the terminal using the unsolicited result code CMTI lt mem gt lt index gt SMS DELIVER except class2 SMS are routed directly to the TE using the unsolicited result code CMT lt alpha lt length gt lt CR gt lt LF gt lt pdu gt in PDU mode or CMT lt oa gt lt alpha gt lt scts gt lt tooa gt lt fo gt lt pid
53. GSM This command is used to set the max tx power threshold for GSM Test command can query the supported parameter list And the default value is the maximum one Read command can query the current threshold Set command can set the threshold the value is volatil and the parameter range is 9dbm For GSM850 900 the default value is 29dbm and for GSM1800 1900the default value is 26dbm All bands parameters should be set no matter they are supported or not And it will not take effect for those bands which are not supported Command Syntax Response Action Remarks Set BODYSARGSM lt OK PWR1 gt lt PWR2 gt lt P oe WR3 gt lt PWR4 gt ERROR Read BODYSARGSM BODYSARGSM lt PWR1 gt lt PWR2 gt lt PW H3 Family AT Commands User Manual Page 233 of 375 FIDCCON R3 gt lt PW R4 gt OK Test BODYSARGSM BODYSARGSM list of supported lt PWR1 gt lt PW R2 gt lt PW R3 gt lt PWR4 gt s OK The following table shows the BODYSARGSM parameters lt Parameter gt Description lt PWR1 gt Threshold for GSM850 dBm lt PWR2 gt Threshold for GSM900 dBm lt PWR3 gt Threshold for GSM1800 dBm lt PWR4 gt Threshold for GSM1900 dBm Example AT BODYSARGSM BODYSARGSM 25 33 25 33 22 30 22 30 OK AT BODYSARGSM BODYSARGSM 29 29 26 26 OK AT BODYSARGSM 33 28 25 22 OK H3 Family AT Commands User Manual Page 234 of 3
54. H3 Family AT Commands User Manual Page 91 of 375 FIDCCON 5 5 3 CAMM Accumulated Call Meter Maximum This command sets the Advice of Charge accumulated call meter maximum value in the SIM file EFACMmax ACMmax contains the maximum number of home units the subscriber is able to consume When the ACM Refer to CACM Accumulated Call Meter reaches ACMmax additional calls mobile originated and mobile terminated calls that incur charges are prohibited except for emergency calls Refer to GSM 02 24 Command Syntax Response Action Remarks Set CAMM OK The Set command sets the accumulated lt acm CME ERROR call meter maximum value SIM PIN2 is _max gt 2 required The value that is set remains err gt lt passw after a power cycle d gt paw Note This command is activated if Advice of Charge is supported by the network Read CAMM CAMM x The Read command displays the current 7 lt acmmax gt value of ACMmax OK Test CAMM OK The Test command indicates whether the CAMM command is functioning The following table shows the CAMM parameters lt Parameter gt Description lt acmmax gt Accumulated call meter maximum value similar to CCM Refer to CAOC Advice of Charge lt ccm gt String type three bytes of the current call meter value in hexadecimal format for example 00001E indicates a decimal value of 30 Value is given in home units b
55. H3 Family AT Commands User Manual Page 47 of 375 FIDCCON CC setup error CC modification error CC release SM attach error SM detach SM activation error SM deactivation SS network error cause SS network reject cause SS network GSM cause lt cause gt contains a digit representing the error cause sent by network or internally lt description gt Is a verbose string containing the textual representation of the Cause H3 Family AT Commands User Manual Page 48 of 375 FiDCCON 5 Call Control 5 1 Managing a CSD Data Call The H3xx working modes can be divided into two modes of operation Data Mode In this mode once the H3XX has established a link with the remote modem it does not respond to any data passing through it except for the Escape Sequence search The H3xx becomes a transparent link connecting the terminal with the remote side Command Mode In this mode the H3xx responds to the AT commands issued by the terminal This is the default working mode Note It is possible to switch between the operating modes The operating modes can operate simultaneously using the Mux and using multi channels operation 5 1 1 Simple Dialing In order to instruct the modem to dial a remote modem from an ordinary tone dialing telephone line enter the Dial command followed by the phone number For example type the followi
56. MHz band 380 selection of 380 MHz band 410 selection of 410 MHz band 710 selection of 710 MHz band 810 selection of 810 MHz band BAND_UMTS_I BAND_UMTS BAND_UMTS Il BAND_UMTS I BAND_UMTS Ill BAND_UMTS_III BAND_UMTS_IV BAND_UMTS_IV BAND_UMTS_V BAND_UMTS_V H3 Family AT Commands User Manual Page 193 of 375 FIDCCON BAND_UMTS_VI BAND_UMTS_ VI BAND_UMTS_VII BAND_UMTS_ VII BAND_UMTS_VIII BAND_UMTS_VIII BAND_UMTS_IX BAND_UMTS_IX BAND_UMTS_X BAND_UMTS_X BAND_UMTS_XI BAND_UMTS_XI BAND_UMTS_XII BAND_UMTS_XIl BAND_UMTS_XIIl BAND_UMTS_XIII BAND_UMTS_XIV BAND_UMTS_XIV BAND_UMTS_XV BAND_UMTS_XV BAND_UMTS_XVI BAND_UMTS_XVI BAND_UMTS_XVII BAND_UMTS_XVII BAND_UMTS_XVIII BAND_UMTS_ XVIII BAND_UMTS_XIX BAND_UMTS_XIX BAND_UMTS_XX BAND_UMTS_XX BAND_UMTS_XxXI BAND_UMTS_XxI BAND_UMTS_XXIl BAND_UMTS_XxIl 9 1 10 MCELL H3xx Cell Description This command only support when module register GSM net UMTS not supported This command displays information about the Cellular Network The information is divided throughout 20 screens each of them with different parameters data Note For H350 xxx 10 H380 this commands is not supported Command Syntax Response Action Remarks Set MCELL lt mo OK The Set command will return OK de gt only The relevant lt screen_info gt lt screen_num gt will return back with MCELL format few senconds later CME ERROR lt err gt
57. Off as default A subscriber to Temporary mode always has a default subscription to state A or B Temporary mode provisioning means that the terminal can request the H3xx to switch the default mode from A to B and vice versa Note When a service is in state A and the terminal wants to enable the CLI presentation turn CLIR off for a single call it can do so using the ATD command This does not change the Temporary mode state This can also be done when the service is in state B and the terminal wants to disable the CLI presentation turn CLIR on for a single call Command Syntax Response Action Remarks Set CLIR lt n gt OK The Set command instructs the H3xx to or enable disable CLI restriction for all MO calls CME ERROR lt err gt Read CLIR CLIR lt n gt lt m gt The Read command returns the current OK setting of CLIR on the network lt m gt and on the H3xx lt n gt H3 Family AT Commands User Manual Page 72 of 375 FIDCCON Test CLIR CLIR list of The Test command returns lt n gt values supported lt n gt s supported by the H3xx The following table shows the CLIR parameters lt Parameter gt Description lt n gt Adjustment for outgoing calls 0 Presentation indicator is used according to the subscription of the CLIR service 1 CLIR invocation 2 CLIR suppression The default value is 2 lt m gt Subscriber CLIR service statu
58. Page 9 of 375 FIDCCON 11 2 General Audio COMIMANGS ee cceeseceseeceesesesesecessececesesesssnencaescecsesesesscseeseaessecescsesesseneeeaeseeneneseaeeneeeees 238 11 2 1 CRSL Call Ringer LeVel ccc ccccccsssseseesesesseseescseeecsesesseeeseseaesecaesessesesaenesseseeseseesesesseeesaees 238 11 2 2 CLVL Loudspeaker VOlUMe c cc ccccccccsccsscscesscscsscescsscsecsecssesecsesscesesecssesecsecseessseceseseceecsecsecaes 239 11 2 3 CMUT Mute Unmute Microphone and Speaker Path ccc cccccscscesscseesscseeseeecssceeeeenees 239 11 2 4 S94 Sidetone Effect sssssssssssssssssessecesscsesscsessssessseesssescssescssesssaesessesessesessesseseseeseesasensass 241 1 1 2 5 S96 Echo Cancelling siiicscchosc nici hiieisiiiiadaees ised Aste essed sears E ENR 241 11 2 6 CALM Alert Sound MOde eeeccceesesesessesssesencsessesecesesescecesesecesseceecsesessecencsesceseaseeseseeeeeeseseaes 242 1152 0 VT1D Tone Duration anid eee en ecient Rees eee eee 243 11 2 8 VTS Command Specific Tone Duration ccc ccccccccsscsscsecsecscesececssceecsecsecsecsecsecseesseseseeees 243 11 2 9 VTA Set play DTMF type ess cssisc scsscseccessstacsscesssecsseseseessceidecsassutencostedee deusaseaass i a NE e E AEE 244 11 2 10 MAPATH AUGIO Pathrot esseere ereraa eera Ee rE E RE ERIR RREA 245 11 2 11 MAVOL Volume Setting ccc ccecccsesscssesecssesceseeceecsecsecsecsecssssececsscsecsecseesecsseseesseeceseseesaeas 248 11 2 12 MATONE Start or stop the t
59. STO SENT 054565034 81 lt message length gt message text OK AT CMGS 18 send to myself gt 079179521201009511000c917952446505430004AA0441424344 CMGS 68 OK AT CPMS sm _ change to SIM to read the incoming messages CPMS 2 20 11 61 2 20 OK H3 Family AT Commands User Manual Page 147 of 375 FHiIDCCON 7 1 15 CMGR Read Message These commands handle the reading of SMS The command displays the message in location lt index gt of the preferred message storage lt mem1 gt selected using the CPMS commana If the status of the message is RECEIVED UNREAD the CMGR command changes the status to RECEIVED READ lt stat gt lt oa gt lt alpha gt lt scts gt lt tooa gt lt fo gt lt pid gt lt dcs gt lt sca gt lt tosca gt lt lengt h gt lt CR gt lt LF gt lt data gt If text mode CMGF 1 command execution is successful and SMS SUBMIT CMGR lt stat gt lt da gt lt alpha gt lt toda gt lt fo gt lt pid gt lt dcs gt lt vp gt lt sca gt lt tosca gt lt length gt lt CR gt lt LF gt lt d ata gt If text mode CMGF 1 command execution is successful and SMS COMMAND CMGR lt stat gt lt fo gt lt ct gt lt pid gt lt mn gt lt da gt lt toda gt lt length gt lt CR gt lt LF gt lt cdata gt If text mode CMGF 1 command execution is successful and CBM storage CMGR lt stat gt lt sn gt lt mid gt lt dcs g
60. Status This command reports where the device is attached to URC syntax XREG lt Status gt lt Band gt Command Syntax Response Action Remarks Set anus ike DIO Set command enables disables network CME ERROR lt error gt registration status unsolicited result code XREG URC same as read syntax AT XREG XREG Read lt n gt lt State gt lt Band gt Read command gives the status of registration OK li Test AE REE RRE Morar Test command returns list of supported supported lt n gt s lt n gt OK The following table shows the XREG parameters lt Parameter gt Description 0 disable network registration attach status unsolicited result code lt n gt 1 enable network registration attach status unsolicited result code H3 Family AT Commands User Manual Page 192 of 375 FIDCCON XREG lt State gt 0 not registered 1 registered GPRS attached 2 registered EDGE attached 3 registered WCDMA attached 4 registered HSDPA attached with DFS22 21 00 DFSD23 09 01 5 registered HSUPA attached with DFS22 21 00 DFSD23 09 01 6 registered HSUPA and HSDPA attached 7 registered GSM 8 registered HSPA attached lt Band gt 900 selection of 900 MHz band 1800 selection of 1800 MHz band 1900 selection of 1900 MHz band 850 selection of 850 MHz band 450 selection of 450 MHz band 480 selection of 480 MHz band 750 selection of 750
61. This command changes the current directory to root directory of remote file system there is no need to change the login account information or transimission parameter Command Syntax Response Action Remarks Set FTPCDUP OK FTPCDUP lt result gt or ERROR The command execution result return to the user as an unsolicited H3 Family AT Commands User Manual Page 352 of 375 FIDCCON lt error_code gt response 0 operation fails 1 operation success Read FTPCDUP ERROR Not supported Test FTPCDUP ERROR Not supported Example AT FTPPWD FTPINFO PWD OK FTPINFO 257 export home test 1234 is current directory FTPPWD 2 export home test 1234 is current directory FTPPWD 1 AT FTPCDUP FTPINFO CDUP OK FTPINFO 250 CWD command successful FTPCDUP 1 AT FTPPWD FTPINFO PWD OK FTPINFO 257 export home test is current directory FTPPWD 2 export home test is current directory FTPPWD 1 14 10 FTPDEL Delete the File This command is used for delete the file on server sites Command Syntax Response Action Remarks Set FTPDEL lt file_n ame gt OK FTPDEL lt result gt or ERROR lt error_code gt lt file_name gt is a complete qualified path and file name on server sites The command execution result H3 Family AT Commands User Manual Page 353 of 37
62. address is cancelled The default value is 1 10 1 6 amp D Circuit 108 Behavior This command determines how the H3xx responds when the DTR Data Terminal Ready status is changed from ON to OFF during the online data state DTR is an input line that indicates that the terminal is ready The DTR line must be active low for the H3xx to recognize the terminal This signal is raised by the terminal when a process activates the serial port If DTR is not used by the application it should connect this line to ground DTR active The default value is active low In case of local link during initial PPP retries DTR change will be ignored Command Syntax Response Action Set AT amp D lt param gt OK Read AT amp D amp D lt param gt Test AT amp D amp D list of supported lt param gt s H3 Family AT Commands User Manual Page 210 of 375 FIDCCON The following table shows the amp D parameters lt Parameter gt Description lt param gt H3xx s reaction when the DTR status is changed from ON to OFF In CSD calls 0 Ignore DTR changes 1 Switches the CSD call to asynchronous command mode the call remains connected 2 Disconnects the call and returns to the command mode In GPRS calls The behavior of is same as DTR signal changed from ON to OFF 0 Ignore DTR changes and command 1 Switch the GPRS session to asynchronous command m
63. books cannot be edited the CPBW command does not work on them 6 1 1 CPBS Select Phone Book Memory This command handles the selection of the memory to be used for reading and writing entries in the H3xx s phone books memory Command Syntax Response Action Remarks Set OK The Set command selects the aes phone book memory storage AT CPBS lt which is to be used by other f CME ERROR storage gt lt pi phone book commands as lt err gt na The Read command returns the lt pin2 gt is currently selected phone book optional while memory number of used entries lt storage gt and total number of entries in the FD only phone book memory Read CPBS CPBS The Read command returns the currently selected phone book lt storage gt memory number of used entries lt used gt lt tot nee and total number of entries in the al gt phone book memory OK FIDCCON Test CPBS CPBS list of Test command returns the supported lt storage gt supported storages as a s compound value OK The following table shows the CPBS parameters lt Parameter gt Description lt storage gt List of supported phone books and their storage IDs FD SIM Fixed dialing phone book ON Own numbers MSISDNs list reading this storage is also available through CNUM SM SIM phone book LD SIM last dialing phonebook BL Blacklist phonebook delete only
64. class gt lt Maximum bitrate UL gt lt Maximum bitrate DL gt lt Guaranteed bitrate UL gt lt Guaranteed bitrate DL gt lt Delivery order gt lt Maximum SDU size gt lt SDU error ratio gt lt Residual bit error ratio gt lt Delivery of erroneous SDUs gt lt Transfer delay gt lt Traffic handling priority gt lt CR gt lt LF gt CGEQNEG lt cid gt lt Traffic class gt lt Maximum bitrate UL gt lt Maximum bitrate DL gt lt Guaranteed bitrate Set command allows the TE to retrieve the negotiated QoS profiles returned in the Activate PDP Context Accept message H3 Family AT Commands User Manual Page 291 of 375 FIDCCON UL gt lt Guaranteed bitrate DL gt lt Delivery order gt lt Maximum SDU size gt lt SDU error ratio gt lt Residual bit error ratio gt lt Delivery of erroneous SDUs gt lt Transfer delay gt lt Traffic handling priority gt Test AT CGEQNEG CGEQNEG list of lt cid gt s associated with Test command active contexts returns a list of lt cid gt s associated with active contexts The following table shows the CGEQNEG parameters lt Parameter gt Description lt cid gt A numeric parameter which specifies a particular PDP context definition see CGDCONT and CGDSCONT commands lt Traffic class gt A numeric parameter that indicates the type of application for which the UMTS bearer servic
65. command displays 456 000 5 5 5 CR Service Reporting Control This command controls whether or not the extended format of an outgoing call is displayed or not The CR indication is sent from the H3xx to the terminal whenever a data call is initiated by the H3xx Command Syntax Response Action Remarks Set CR lt mode gt OK The Set command enables disables the extended format of an outgoing data call H3 Family AT Commands User Manual Page 94 of 375 FIDCCON When enabled the outgoing data call is indicated to the terminal through the unsolicited result code CR lt serv gt When the command is disabled no CR is sent to the terminal 9 Read TORI PERE MOUDE The Read command displays the current OK service reporting control setting Test CR CR lt mode gt The Test command displays the list of OK supported CR modes The following table shows the CR parameters lt Parameter gt Description lt mode gt 0 Extended format disabled default 1 Extended format enabled lt serv gt Type of outgoing data calls ASYNC Asynchronous transparent SYNC Synchronous transparent REL ASYNC Asynchronous non transparent REL SYNC Synchronous non transparent Example AT CR 1 Enable reporting OK ATD1234567890 CR REL ASYNC H3 Family AT Commands User Manual Page 95 of 375 FIDCCON 5 6 Supplementary Services Th
66. dd hh mm ss or yy MM dd hh mm yy 2 digit year 2000 2069 MM 2 digit month 01 12 dd 2 digit day of month 00 31 hh 2 digit hour 00 23 mm 2 digit minute 00 59 ss 2 digit seconds 00 59 zz optional time zone offset from GMT in quarter hours 47 48 If this value is not specified the time zone offset will be 0 Example AT CCLK CCLK 88 12 31 23 59 59 47 48 OK AT CCLK 01 01 01 01 01 01 08 OK AT CCLK CCLK 01 01 01 01 01 01 08 OK AT CCLK 02 02 02 02 02 02 OK Power cycling AT CCLK CCLK 02 02 02 02 02 02 00 OK H3 Family AT Commands User Manual Page 119 of 375 FIDCCON 7 SMS 7 1 SMS Commands H3xx supports SMS PDU and SMS TEXT mode according to ETSI specifications 3GPP TS 27 005 amp 3GPP TS 03 40 23 0400 7 1 1 CSMS Select Message Service This command handles the selection of the messaging service supported by the H3xx It returns the types of messages that are Command Syntax Response Action Remarks Set CSMS CSMS lt mt gt lt mo gt lt bm gt The Set command sets the type of lt servic OK service and returns the types of e gt messages supported by the H3xx or CMS ERROR lt err gt Read CSMS CSMS The Read command returns the 5 ssena amia mon ms supported message types along with the current service setting OK Test FSM TE oMr RETOR The Test command returns a list o
67. ee OPO R Ie eT er reaE 120 MEU aS ORIN ANNO Senese noaa aae ea aN rasa Raa 120 7 1 1 CSMS Select Message Service ccc ccccccccccsscssesseseescesesscssesecsscsecsssecescsecsecsecsecsecsecsceseeessaeees 120 7 1 2 CPMS Preferred Message Storage cccccccccsessccsesscssesecsscsecsssecescsecacsecsecsecsececcseceeseceeseeeees 121 7 1 3 CMGF Message Format ccccccccccccccsscsscsscsseseeseescesesecsesecsseseesesscesesecsecsecsecsecsecsseseeseaseesseensess 123 71 4 4GSCA Service Center AAG ESS ieccsassssscil ta cierans tempi eneuieniansea aad eaalgaaeheee 124 7 1 5 CSMP Set Text Mode Parameters cecececcssscessseseeceescseseseeeeeeseeeseeceseacecseseeeeaeeeeeeeateeeeeees 128 7 1 6 CSDH Show Text Mode ParamiGte rs sss scdcssicssacacasseneceacenataiveiesiasensenadeieocasadiendacavaiantedestepstantoionees 130 7 1 7 CNMI New Message Indications to Terminal cccccccccsccscescesesscesesecsseseesssscesesecescseeseeaes 132 7 1 8 CNMA New Message AcknowledgQment ccccecsssssessseeseeseseeseeesececseesesesseseeseseeseenseseeseeeeaees 135 H3 Family AT Commands User Manual Page 7 of 375 FIDCCON 7 1 9 CMTI Unsolicited Response New SMS DELIVER Receipt Indication c eee 138 7 1 10 CMT Unsolicited Response New SMS DELIVER ReCeipb cccceeseeseeesereeeeteeeeteeees 138 7 1 11 CBM Unsolicited Response New CB Message ReCeipt ccccseeceescesseseeseeseeseteeees 140 7 1 12 CDSI Unso
68. entered during a voice call Yes 5 Call on hold has been released during a voice call not Yes a supplementary service notification 6 Forward check supplementary service message Yes received can be received at any time 7 Call is being connected with the remote party in an Yes alerted state using an explicit call transfer operation during a voice call 8 Call has been connected with the other remote party Yes using an explicit call transfer operation during a voice call or during mobile terminated call setup Number and subaddress parameters may be present lt number gt String type phone number of format defined by lt type gt H3 Family AT Commands User Manual Page 98 of 375 FIDCCON lt type gt Type of address octet in integer format refer to GSM04 08 subclause 10 5 4 7 lt subaddr gt String type subaddress of format defined by lt satype gt lt satype gt Type of subaddress octet in integer format refer to GSM 04 08 subclause10 5 4 8 9 Deflected call YES mobile terminated call setup 10 additional incoming call forwarded YES Example AT CSSN test command CSSN 0 1 0 1 OK AT CSSN 0 0 disable both options OK AT CSSN 1 0 set n value as enabled m disabled OK AT CSSN CSSN 1 0 display the current n amp m values OK CSSI 1 displayed after mobile originated call setup of call forward and n enable CSSU 2 displayed when a call ha
69. error gt f which has been signalled to the TE by the RING or CRING unsolicited result code Test AT CGANS CGANS list of The test command returns the values of supported lt response gt and lt L2P gt supported by lt response gt s list of the MT as compound values supported lt L2P gt s H3 Family AT Commands User Manual Page 275 of 375 FIDCCON The following table shows the CGANS parameters lt Parameter gt Description lt response gt A numeric parameter which specifies how the request should be responded to 0 reject the request 1 accept and request that the PDP context be activated If lt response gt is omitted it is assumed to be 0 Other values are reserved and will result in the ERROR response lt L2P gt A string parameter which indicates the layer 2 protocol to be used see CGDATA command lt cid gt A numeric parameter which specifies a particular PDP context definition see the CGDCONT and CGDSCONT commands The lt response gt parameter allows the TE to accept or reject the request If lt response gt is 0 the request is rejected and the MT returns OK to the TE If lt response gt is 1 the following procedure is followed by the MT Commands following the CGANS command in the AT command line shall not be processed by the MT If the lt L2P gt parameter value is unacceptable to the MT the MT shall return an ERROR or CME ERROR
70. following table shows the amp Y parameters lt Parameter gt Description lt n gt User s profile number 0 Selects power up configuration to user s profile 0 1 Selects power up configuration to user s profile 1 The default value is 0 Example AT amp Y1 OK H3 Family AT Commands User Manual Page 37 of 375 FiIDCCON 4 1 13 CRSM Restricted SIM Access This command provides limited access to the Elementary Files on the SIM Access to the SIM database is restricted to the commands which are listed at lt command gt All parameters of AT tCRSM are used as specified by 3GPP TS 51 011 2G and TS 31 101 3G As response to the command the H3xx sends the actual SIM information parameters and response data Error result code CME ERROR may be returned if the command cannot be transferred to the SIM e g if the SIM is not inserted or defected or PIN1 PUK authentication required or required input parameters not present However failure in the execution of the command in the SIM is reported in lt sw1 gt and lt sw2 gt parameters Some of the AT CRSM commands require PIN PIN2 authentication Note For H350 xxx 10 H380 Test command and only return OK Command Syntax Response Action Remarks Set command transmits the AT CRSM lt CRSM command gt lt sw1 gt lt sw2 gt lt response lt file_id gt lt P gt Set ME 1 gt lt P2 gt lt P3 OK ME sends the actual SIM gt
71. gt lt Residual bit error ratio gt lt Delivery of Command Syntax Response Action Remarks Set AT CGEQREQ lt cid gt OK Set command lt Traffic class gt ERROR specifies a profile for the context identified by the local context identification parameter lt cid gt The specified profile will be stored in the MT and sent to the network only at activation or MS initiated modification of the related context H3 Family AT Commands User Manual Page 285 of 375 FIDCCON erroneous SDUs gt lt Transfer delay gt lt Traffic handling priority gt lt Source statistics descriptor gt lt Signalling indication gt INNMNI Parameter value ranges for each PDP type are returned on a separate line Read AT CGEQREQ CGEQREQ lt cid gt lt Traffic class gt lt Maximum bitrate UL gt lt Maximum bitrate DL gt lt Guaranteed bitrate UL gt lt Guaranteed bitrate DL gt lt Delivery order gt lt Maximum SDU size gt lt SDU error ratio gt lt Residual bit error ratio gt lt Delivery of erroneous SDUs gt lt Transfer delay gt lt Traffic handling priority gt lt Source statistics descriptor gt lt Signalling indication gt lt CR gt lt LF gt CGEQREQ lt cid gt lt Traffic class gt lt Maximum bitrate UL gt lt Maximum bitrate DL gt lt Guaranteed bitrate UL gt lt Guaranteed bitrate DL gt lt Delivery order gt lt Maxi
72. gt lt CR gt lt LF gt lt data gt about parameters in italics refer command Show Text Mode Parameters CSDH In PDU mode CMGF 0 CMT lt alpha gt lt length gt lt CR gt lt LF gt lt pdu gt The following table shows the CMT parameters lt Parameter gt Description lt oa gt Message origination address lt scts gt Service center time stamp lt tooa gt Type of origination address lt fo gt First octet of the SMS lt pid gt Protocol Identifier lt dcs gt Data Coding Scheme lt sca gt Service Center Address lt tosca gt Type of Service Center Address lt data gt Message contents lt alpha gt Alpha ID of message lt length gt In PDU mode Size of message in octets excluding SMSC data In TEXT mode number of characters included in the lt data gt lt pdu gt Message header and contents in PDU mode format See description in CMGR Read Message After sending a CMT unsolicited response to the TE the H3xx will expect a CNMA new message acknowledgement from the TE within a predefined timeout of 15 seconds Within the timeout the H3xx will not send another CMT unsolicited response to the TE before the previous one is acknowledged If H3 Family AT Commands User Manual Page 139 of 375 FIDCCON the CMT is acknowledged within the timeout the new SMS is not saved in the message storage If the H3xx does not receive acknowledgmen
73. gt s list of supported lt source address and subnet mask gt s list of supported lt protocol number ipv4 next header ipv6 gt s list of supported lt destination port range gt s list of supported lt source port range gt s list of supported lt ipsec security parameter index spi gt s list of supported lt type of The test command returns values supported as a compound value H3 Family AT Commands User Manual Page 302 of 375 FIDCCON service tos ipv4 and mask traffic class ipv6 and mask gt s list of supported lt flow label ipv6 gt s lt CR gt lt LF gt CGTFT lt PDP_type gt list of supported lt packet filter identifier gt s list of supported lt evaluation precedence index gt s list of supported lt source address and subnet mask gt s list of supported lt protocol number ipv4 next header ipv6 gt s list of supported lt destination port range gt s list of supported lt source port range gt s list of supported lt ipsec security parameter index spi gt s list of supported lt type of service tos ipv4 and mask traffic class ipv6 and mask gt s list of supported lt flow label ipv6 gt s The following table shows the CGTFT parameters lt Parameter gt Description lt cid gt a numeric parameter which specifies a particular PDP context definition see the CGDCONT and
74. it possible for sharing the data among different hosts FTP use C S mode the client can download files and upload files as well Of course FTP gives the user certain authority user can only use it under authority There are many types of FTP Server currently like commonly used SERV U as well as client program like CuteFTP WINDOWS also provided a FTP client program Note For H350 xxx 10 H380 No FTP commands are supported 14 2 FTPOPEN Open a FTP Connection with FTP Server This command is used for opening the connection between the module and FTP Server by sending user and password authentication Note e Only one FTP connection can be in progress each time e After the connection is opened there is going to be a 120 seconds timeout exit if no FTP operation exists Command Syntax Response Action Remarks Set FTPOPEN OK FTPOPEN Command execution lt destination_ip url lt connection_status gt Or ERROR result connection status gt lt username gt lt error_code gt return to the user as an lt password gt lt ac unsolicited response count gt lt source_con 1 connection success trol_port gt lt destinati iol s 0 connection fail on_control_port gt lt source_data_port gt H3 Family AT Commands User Manual Page 344 of 375 FIDCCON Read FTPOPEN FTPOPEN lt connection_status gt Returns FTP connection OK status 1 connection success 0
75. its own CSSU result code Note The values for lt n gt and lt m gt are not saved after power cycle mead bea A The Read command displays the current OK supplementary service notification setting Test CSSN CSSN 0 1 0 1 The Test command displays the list of OK supported CSSN values The following table shows the CSSN parameters lt Parameter gt Description lt n gt Sets displays the CSSI result code presentation status This value must be specified 0 Disable default 1 Enable lt m gt Sets displays the CSSU result code presentation status This value is optional but cannot be specified without lt n gt 0 Disable default 1 Enable Value Description H3xx Support 0 Unconditional call forwarding is active Yes 1 Some conditional call forwarding is active Yes 2 Call has been forwarded Yes 3 Call is waiting Yes GSM only 4 CUG call lt index gt is present Yes H3 Family AT Commands User Manual Page 97 of 375 FIDCCON 5 Outgoing calls are barred Yes 6 Incoming calls are barred Yes 7 CLIR suppression rejected Yes 8 Call has been deflected No Value Description H3xx Support 0 This is a forwarded call Yes mobile terminated call setup 1 CUG call lt index gt is present mobile terminated call Yes setup 2 Call has been put on hold during a voice call Yes 3 Call has been retrieved during a voice call Yes 4 Multiparty call has been
76. lt data gt lt p or infor mation parameters and athid gt CME ERROR lt err gt SIM lt command gt and its required parameters to the response data CRSM list of supported lt command gt s possible lt file_id gt s range value possible The test command returns the AT CRSM Test a lt P1 gt range value possible ranges of CRSM l possible lt P2 gt range Parameters value possible lt P3 gt range value OK or CME ERROR lt err gt H3 Family AT Commands User Manual Page 38 of 375 FIDCCON The following table shows the CRSM parameters lt Parameter gt Description lt command gt Integer type Command passed on by the ME to the SIM 176 Read BINARY 178 Read RECORD 192 Get RESPONSE 214 Update BINARY 220 Update RECORD 242 STATUS lt file_id gt Integer type This is the identifier of a elementary data file on SIM Mandatory for every lt command gt except of STATUS lt P1 gt lt P2 gt lt P3 gt Integer type Parameters passed on by the ME to the SIM These parameters are man datory for every command except GET RESPONSE and STATUS READ BINARY lt P1 gt Offset high 0 255 lt P2 gt Offset low 0 255 lt P3 gt Length 0 255 READ BINARY lt P1 gt Rec No 0 255 lt P2 gt Mode 02 next record 03 previous record 04 absolute mode current mode the record number is given in P1 with
77. lt ds gt 0 No SMS STATUS REPORT indications are routed to the terminal default 1 SMS STATUS REPORT is routed directly to the terminal 2 If SMS STATUS REPORT is stored in the H3xx the memory locationindication is routed to the terminal using the unsolicited result code CDSI lt mem gt lt index gt lt bfr gt 0 TA buffer of unsolicited result codes defined within this command is flushed to the TE when lt mode gt 1 3 is entered OK response shall be given before flushing the codes 1 TA buffer of unsolicited result codes defined within this command is cleared when lt mode gt 1 3 is entered Example AT CNMI CNMI 0 2 0 3 0 3 0 2 0 1 OK AT CNMI CNMI 0 0 0 0 OK AT CNMI 2 1 OK AT CMSS 142 0544565034 send to myself CMSS 72 OK CMTI SM 15 AT CNMI 1 2 OK AT CSDH 1 OK AT CMSS 142 054565034 CMSS 73 H3 Family AT Commands User Manual send to myself Page 134 of 375 FIDCCON CMT 972544565034 04 11 04 09 48 36 08 145 4 0 0 97254120032 145 3 ABC AT CSMP 49 167 Set first octet to status report See status report parameters in CMGW OK AT CSMP CSMP 49 167 0 0 OK AT CNMI 1 1 OK AT CNMI CNMI 1 0 0 1 0 OK AT CNMI 1 0 0 1 0 OK AT CMGS 0524680592 gt HELLO CMGS 168 OK CDS 6 168 972524680592 145 05 08 02 15 20 12 08 05 08 02 15 20 14 08 0 AT CNMI 1 0 0 2 OK AT CMSS 296 CMSS 185 OK CDSI SM 6 7 1 8 CNMA
78. mode and slave mode transmission mode sampling rate and word width The setting is invalid when MADIGITAL is 0 Command Syntax Response Action Remarks Set MAI2SY OK Notice that it matches lt master gt lt tran_m r with the module ode gt lt sample gt lt parameters when use ERROR width gt external CODEC otherwise the external CODEC may not able to receive the audio H3 Family AT Commands User Manual Page 257 of 375 FIDCCON data correctly Read MAI2SY MAI2SY Read the current lt master gt lt tran_mode gt parameter value lt samp le gt lt width gt OK Test MAI2SY MAI2SY Parameter range lt 0 1 gt lt 0 1 gt lt 0 1 2 3 4 gt lt 0 1 2 gt OK The following table shows the MAI2SY parameters lt Parameter gt Description lt master gt Set data transmission to master mode or slave mode 0 module is in master mode external CODEC is in slave mode 1 module is in slave mode external CODEC is in master mode lt tran_mode gt Data Transimisson Mode 0 I2S mode 1 PCM mode lt sample gt Sampling rate 0 8k 1 16k 2 24K 3 32K 4 44 1K H3 Family AT Commands User Manual Page 258 of 375 FIDCCON lt width gt Word width 0 16BIT 1 24BIT 2 32BIT Example AT MAI2SY 0 0 0 0 set the module to master mode I2S sampling rate to 8K width to 16BIT
79. ms lt T2 gt must be longer than lt T1 gt H3 Family AT Commands User Manual Page 230 of 375 FIDCCON 2 255 The default value is 30 300 ms lt T3 gt Wake up response timer in seconds 1 255 The default value is 10 lt k gt Reserve for Advanced operation with Error Recovery options 10 5 Clock Configuration Note For H330S and H350 xxx 00 all clock configuration commands are not supported 10 5 1 CLKOUTO 26MHz Clock Output From CLKOUTO This command is used for controlling the 26MHz clock output from CLKOUTO and by default the clock is switched off Command Syntax Response Action Remarks Set AT CLKOUTO lt n gt OK Switch on off 26MHz or clock output from PIN CLKOUTO CME ERROR lt err gt Read AT CLKOUTO CLKOUTO lt n gt Query the current status OK of PIN CLKOUTO Test AT CLKOUTO CLKOUTO list of Query the range of the supported lt n gt s parameters OK The following table shows the CLKOUTO parameters lt Parameter gt Description lt n gt O switch off the clock default value 1 switch on the clock H3 Family AT Commands User Manual Page 231 of 375 FIDCCON 10 5 2 CLK32k 32KHz Clock Output From CLK32K This command is used for controlling the 26MHz clock output from CLKFSYS1_26M and by default the clock is switched off Command Syntax Response Action Remarks Set AT CLKFSYS
80. parameters lt Parameter gt Description File directory name This is a valid path and file standard in the server system string the max length is 255 octets File name to Rename as string the max length is 255 octets Example AT FTPLIST FTPINFO TYPE A OK FTPINFO 200 Switching to ASCII mode FTPINFO PASV FTPINFO 227 Entering Passive Mode 183 232 65 2 168 231 FTPINFO LIST FTPLIST 2 rW r r 1 602 rW r r 1 602 rW r r 1 602 drwxr xr x 2 602 drwxr xr x 2 602 404 184 Jul 14 08 17 1234 txt 404 92 Jul 14 08 12 12345 txt 404 1048663 Jul 13 10 10 1M 404 4096 Jul 13 03 45 TEST 404 4096 Jul 13 08 25 ghttest H3 Family AT Commands User Manual Page 356 of 375 FIDCCON FTPINFO 150 Here comes the directory listing FTPINFO 226 Directory send OK FTPLIST 1 14 13 FTPSTAT Request Status This command can send out a status as a response by control connection Note This command can include a parameter field if a complete path name is specified STAT is similar with LIST command except the data transmitted by control connection If a local path is specified the server will response by a file or properties list related with the specified item If no parameter is speicifed the sever will return the general status information of this FTP process which include the value and connection status of all current transmission parameters
81. password for the facility newpwd gt lock CME ERROR lt err gt Read AT CPWD CME ERROR lt err gt Test AT CPWD CPWD list of The Test command returns a list of Supported pairs which represent the available lt fac gt lt pwdlength gt facilities and the maximum length of s their passwords OK or CME ERROR lt err gt H3 Family AT Commands User Manual Page 169 of 375 Bs FIBOCOM The following table shows the lt fac gt parameters lt fac gt Description SC SIM lock SIM UICC card SIM UICC asks password in MT power up and when this lock command issued FD SIM card or active application in the UICC GSM or USIM fixed dialling memory feature if PIN2 authentication has not been done during the current session PIN2 is required as lt passwd gt AO BAOC Bar All Outgoing Calls Ol BOIC Bar Outgoing International Calls OX BOIC exHC Bar Outgoing International Calls except to Home Country Al BAIC Bar All Incoming Calls IR BIC Roam Bar Incoming Calls when Roaming outside the home country AB All Barring services applicable only for lt mode gt 0 AG All outgoing barring services applicable only for lt mode gt 0 AC All incoming barring services applicable only for lt mode gt 0 P2 SIM PIN2 The following table shows the CPWD parameters lt Parameter gt Description lt fac gt List of supported facilitie
82. response Otherwise the MT issues the intermediate result code CONNECT and enters V 250 online data state If no lt cid gt is given or if there is no matching context definition the MT will attempt to activate the context using the values for PDP type and PDP address provided by the network together with any other relevant information known to the MT The other context parameters will be set to their default values If the activation is successful data transfer may proceed Example AT CGANS CGANS 0 1 PPP M OPT PPP M HEX M RAW_IP OK Note This is not the same as if the MT issues a CGDATA or CGACT command after receiving a CRING unsolicited result code A CGDATA or CGACT does not command the MT to acknowledge H3 Family AT Commands User Manual Page 276 of 375 FIDCCON the network request but rather to make a new request for context activation The network request would be ignored 12 2 10 CGAUTO Automatic Response to a Network Request for PDP Context Activation The set command disables or enables an automatic positive or negative response auto answer to the receipt of a NWinitiated Request PDP Context Activation message from the network in UMTS GPRS and a NW initiated Request EPS Bearer Activation Modification Request messages in EPS It also provides control over the use of the V 250 basic commands S0 A and H for handling network requests for PDP context activation The setting does not
83. stack Data chunks between the terminal and the H3xx are limited to be smaller than 1024 bytes 2048 characters in coded form In order to reduce the overhead of sending small amounts of data over the air the H3xx uses an accumulating buffer The terminal can specify a watermark within the accumulating buffer size limits to indicate how much data should be accumulated The data in accumulating buffer will be push into the protocol stack either the buffer is full or the data length reach the watermark Arriving data to accumulating buffer triggers a start of time defined in timeout countdown When counter H3 Family AT Commands User Manual Page 314 of 375 FIDCCON reaches zero data is moved into the protocol stack If new data arrived before time is reached zero it is re initialized If data in accumulating buffer reached watermark it is pushed to the accumulating buffer as usual but if after automatic push there is some remaining data time countdown is started Note If there is data in the accumulating buffer the MIPSETS command will be rejected Command Syntax Response Action Remarks Set MIPSETS lt Soc OK Timeout is ket_ID gt lt Size gt lt r defined in Timeout gt milliseconds ERROR MIPSETS lt err gt Read MIPSETS MIPSETS lt Socket_ID gt lt Current Size Settings gt lt Timeout gt OK For all ACTIVE sockets Test MIPSETS MIPSETS 1 4 list of supported lt size g
84. terminal when data is received from the TCP protocol stack Set Command Event MIPRTCP lt socket_ID gt lt Left or SDL gt lt Data gt The following table shows the MIPRTCP parameters lt Parameter gt Description Socket_ID 1 2 3 4 Number of valid sockets Left Size of received Data still left in protocol stack SDL Subsequent data length Data Data string received with 0 F hexadecimal digits String ends with a lt CR gt Note This unsolicited event will change the destination IP and destination port it means that when a MIPRUDP unsolicited event coming if you do not specify IP and port using MIPPUSH data left in the buffer will be sent to this new destination by default If IPRFMT parameter has been set by AT GTSET the received data will be reponse at different format Example MIPRTCP 3 0 7171 H3 Family AT Commands User Manual Page 327 of 375 FiIDCCON 13 12 MIPSTAT Status Report This unsolicited event is sent to the terminal indicating a change in status Currently there are two possible sources of failure a broken logical connection or a broken physical connection Syntax MIPSTAT lt socket_ID gt lt n gt lt number_of_acknowledged_bytes gt The following table shows the MIP STAT parameters lt Parameter gt Description lt Socket_ID gt A unique number that identifies a connection Valid socket numbers 1 2 3 and 4 lt n gt 0
85. the settings Command Syntax Response Action Remarks Set MTSM lt Report For lt Report gt 0 Read the gt lt Rate gt lt Low temperature OK gt lt High gt For lt Report gt 1 MTSM lt Temp gt OK For lt Report gt 2 or 3 H3 Family AT Commands User Manual Page 217 of 375 FIDCCON OK MTSM lt Temp gt MTSM lt Temp gt or ERROR lt error code gt Read MTSM MTSM lt Report gt lt Rate gt lt Low gt Read the setting lt High gt parameters OK Test MTSM MTSM range of lt Report gt range of lt Rate gt range of lt Low gt lt High gt OK The following table shows the MTSM parameters lt Parameter gt Description lt Temp gt 40 125 Temperature measurements in Celsius degrees lt Report gt 0 Deactivate unsolicited report 1 Report once the current temperature 2 Activate unsolicited report 3 Activate unsolicited report only for out off boundaries events 6 Report the temperature of BBIC 7 Report the temperature of RF 8 Report the temperature of PCB Not support yet 9 Report the temperature of BAT lt Rate gt 1 255 Select the time interval in seconds between the unsolicited reports Default value 1 Second H3 Family AT Commands User Manual Page 218 of 375 FIDCCON lt Low gt 0 125 The lowest boundary level of the temperature value for unso
86. the current call cost 5 5 2 CACM Accumulated Call Meter This command resets the Advice of Charge accumulated call meter value in the SIM file EFACM ACM contains the total number of home units for both the current call and preceding calls Command Syntax Response Action Remarks Set CACM OK The Set command resets the lt pass CME ERROR accumulated call meter value SIM PIN2 wee lt err gt is required H3 Family AT Commands User Manual Page 90 of 375 FIDCCON Read CACM CACM lt acm gt 5 The Read command displays the TOMEERROR current value of ACM lt err gt Test CACM OK The Test command indicates whether the CACM command is functioning The following table shows the CACM parameters lt Parameter gt Description lt passwd gt SIM PIN2 password Maximum string length is 8 characters If this value is exceeded the command terminates in an error If PIN2 is incorrect CME ERROR incorrect password is displayed lt acm gt Accumulated call meter maximum value similar to CCM Refer to CAOC Advice of Charge The default value is 0 lt ccm gt String type three bytes of the current call meter value in hexadecimal format for example 00001E indicates a decimal value of 30 Value is given in home units bytes are similarly coded as the ACMmax value in the SIM Example AT CACM OK AT CACM CACM 000000 OK AT CACM 2222 OK
87. the number is entered into the lt text gt field If these fields are omitted the phone book entry is deleted If the lt index gt field is omitted but a number is entered in the lt number gt field the phone number is entered into the first available entry in the phone book If the writing fails in a H3xx error CME ERROR lt err gt is returned Note The FD phone book supports single wild card characters and prefixes of a number in the telephone number field In cases of fixed dialing these entries in the FD phone book define a group of permitted numbers Call indications related to a fixed dialing entry containing wild cards or only a prefix of a number do not H3 Family AT Commands User Manual Page 114 of 375 FIDCCON display any lt alpha gt identifier Command Syntax Response Action Remarks Set AT CPBW lt index gt lt number gt lt type gt lt text gt lt group gt lt adnumber gt lt adtype gt lt secondte xt gt lt email gt lt sip_uri gt lt tel_uri gt lt hidden gt ll OK or CME ERROR lt err gt Test AT CPBW CPBW list of supported lt index gt s lt nlengt h gt list of supported lt type gt s lt tlength gt lt glength gt lt alength gt lt sl ength gt lt elength gt OK This command queries the allowable command field and sizes The following table shows the CPBW parameters lt Par
88. the presence of dial tone when it first goes off hook to begin dialing and whether the engaged tone busy signal detection is enabled Note For H350 xxx 10 H380 ATX are not supported Command Syntax Response Action Remarks Set ATX lt value gt OK The Set command sets the result code bis and call progress monitoring control CME ERROR lt err gt Read ATX lt value gt OK The following table shows the X parameters lt Parameter gt Description lt value gt 0 CONNECT result code given upon entering online data state Dial tone detection Disabled Busy detection Disabled CONNECT lt text gt result code given upon entering online data state Dial tone detection Disabled Busy detection Disabled CONNECT lt text gt result code given upon entering online data state Dial tone detection Enabled Busy detection Disabled H3 Family AT Commands User Manual Page 29 of 375 FIDCCON Dial tone detection Disabled Busy detection Enabled Dial tone detection Enabled Busy detection Enabled The default value is 4 3 CONNECT lt text gt result code given upon entering online data state 4 CONNECT lt text gt result code given upon entering online data state 4 1 5 S Bit Map Registers This command reads writes values of the S registers The H3xx supports this command for various S values according to official specifica
89. the valid AT MPING set command was received by H3xx until MPINGSTAT unsolicited report with lt status gt equal either to 0 or 2 is sent to DTE or ping request execution was aborted with AT MPING 0 command Refer to description of MPINGSTAT unsolicited response for details In some cases the reply message for an Echo Request message might be not an Echo Reply messages but rather some other ICMP message which is reporting an error in datagram processing For purpose of reporting an exact type of response for sent Echo Request message unsolicited response includes lt type gt and lt code gt fields The first octet of the data portion of the IP datagram is an ICMP lt type gt field The value of this field determines the format of the remaining data The lt type gt and lt code gt fields jointly define ICMP message type For example a case when an Echo Request message encapsulated in IP datagram to be forwarded by a gateway has exceeded TTL equal zero In this case the gateway must discard the datagram and may return an ICMP Time Exceeded message Example AT MIPCALL 1 internet OK MIPCALL 10 170 4 111 AT MPING 1 10 170 4 112 II Ping remote computer using default parameters OK MPING 10 170 4 112 0 0 400 Echo Reply message received RTT is 400 ms MPING 10 170 4 112 0 0 420 MPING 10 170 4 112 0 0 440 H3 Family AT Commands User Manual Page 335 of 375 FIDCCON MPING 10 170 4 112 0 0 410 Pin
90. we list the baudrates we tested here but leave all support baudrates in test command return string Example AT IPR 7 OK AT IPR IPR 19200 OK AT IPR IPR 0 20 300 1200 2400 4800 9600 19200 38400 57600 115200 230400 460800 921600 OK H3 Family AT Commands User Manual Page 206 of 375 10 1 3 amp K RTS CTS Flow Control This command configures the flow control RTS Request To Send is an input line The RTS signal is received from the terminal and a low level indicates that H3xx can send more data CTS Clear To Send is an output line The CTS signal is sent to the terminal and a low level indicates that more data can be sent to H3XX The RTS and CTS line together make up what is called RTS CTS or hardware flow control Both lines are used when hardware flow control is enabled in both the terminal and H3xx devices When the terminal is ready and able to receive data it puts the RTS line in an active low condition to indicate this to the H3xx If the terminal is not able to receive data typically because its receive buffer is almost full it puts the RTS line in an inactive high condition as a signal to the H3xx to stop sending data When the terminal is ready to receive more data for example after data has been removed from its receive buffer it places this line back in the active condition The RTS line complements the CTS line The H3XX puts the CTS line in an active condition to tell the termin
91. 0 read 3000 bytes data FTPRECV 8 agps_nv FTPGET 1 OK llit already downloaded when read 8 bytes file GET file downloading completed H3 Family AT Commands User Manual Page 366 of 375 FIDCCON 15 Error Code The list below is a draft List and is still TBD 15 1 CME Error Parameter Description lt Err gt 0 1 2 3 4 5 6 7 10 14 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 30 phone failure no connection to phone phone adaptor link reserved operation not allowed operation not supported PH SIM PIN required PH FSIM PIN required PH FSIM PUK required SIM not inserted SIM PIN required SIM PUK required SIM failure SIM busy SIM wrong incorrect password SIM PIN2 required SIM PUK2 required incorrect PUK1 memory full invalid index not found memory failure text string too long invalid characters in text string dial string too long invalid characters in dial string no network service H3 Family AT Commands User Manual Page 367 of 375 FIDCCON 31 32 40 41 42 43 44 45 46 47 48 49 50 100 103 106 107 111 112 113 114 116 117 132 133 134 135 148 149 150 244 257 258 network timeout network not allowed emergency calls only network personalisation PIN required networ
92. 032 145 lt message length gt message text OK AT CMGW 18 gt 079179521201009511000c91 7952428650290004AA044 1424344 CMGW 143 OK AT CMGR 143 CMGR 2 23 0791795212010095040C91 7952428650290004502032110201800441424344 OK AT CPMS SM change to SM to read SMS DELIVER messages CPMS 2 20 11 61 2 20 OK AT CMGR 1 CMGR REC READ 972544565034 05 02 23 11 20 10 08 145 4 0 4 97254120032 145 4 41424344 OK AT CMGF 0 OK AT CMGR 1 CMGR 0 23 H3 Family AT Commands User Manual Page 151 of 375 FIDCCON 0791 07917952140230F2040C91795244650543000450203211020180044 1424344 OK AT CMGR 14 CMGR 0 25 079179521201009506BC0B91 7952428600F 050803080751 2805080308075128046 II SMS STATUS REPORT message in PDU mode OK AT CMGF 1 OK AT CMGR 14 SMS STATUS REPORT message in Text mode CMGR REC READ 6 188 97252468000 145 05 08 03 08 57 21 08 05 08 03 08 57 21 08 70 OK 7 1 16 CMSS Send Message from Storage This command sends a pre stored message written previously using the CMGW command The lt da gt lt toda gt parameters are optional If a DA is given the message is sent to that address Otherwise the message is sent to the DA it was stored with if any was entered If no DA is found an error occurs When the given index is an incoming message index the header settings will be as follows lt first octet gt will be SMS SUBMIT and VPF relative Th
93. 1 lt n gt OK or CME ERROR lt err gt Switch on off 26MHz clock output from PIN CLKFSYS1_26M Read AT CLKFSYS1 CLKFSYS1 lt n gt Query the current status OK of PIN CLKFSYS1_26M Test AT CLKFSYS1 CLKFSYS1 list of Query the range of the supported lt n gt s parameters OK The following table shows the CLK32K parameters lt Parameter gt Description lt n gt 0 switch off the clock default value 1 switch on the clock 10 5 3 CLKFSYS1 26MHz Clock Output From CLKFSYS1_26M This command is used for controlling the 26MHz clock output from CLKFSYS1_26M and by default the clock is switched off Command Syntax Response Action Remarks Set AT CLKFSYS1 lt n gt OK or CME ERROR lt err gt Switch on off 26MHz clock output from PIN CLKFSYS1_26M H3 Family AT Commands User Manual Page 232 of 375 FIDCCON Read AT CLKFSYS1 CLKFSYS1 lt n gt Query the current status OK of PIN CLKFSYS1_26M Test AT CLKFSYS1 CLKFSYS1 list of Query the range of the supported lt n gt s parameters OK The following table shows the CLKFSYS1 parameters lt Parameter gt Description lt n gt 0 switch off the clock default value 1 switch on the clock 10 6 BODYSAR Feature Note For H330S and H350 xxx 00 bodysar feature is not supported 10 6 1 BODYSARGSM Set Max Tx Power Threshold For
94. 1 1 Scope This section describes the Audio features which includes the following configuration items Path Selection of microphone and speaker to be used Gain Control of volume levels for rings voice etc Algorithm Activation of audio algorithms echo cancellation noise suppression and sidetone Audio Control of Path Gain and Algorithms is available by these two different modes sets of commands It is advised to select the audio mode according to the application needs 11 2 General Audio Commands The following audio commands can be used in audio modes VTD VTS CALM MMICG 11 2 1 CRSL Call Ringer Level This command handles the selection of the incoming call ringer sound level on the curremt speaker of the H3xx The new value remains after power cycle Note For H350 xxx 10 H380 this commands is not supported Command Syntax Response Action Remarks Set CRSL lt level gt OK The Set command sets the call or ringer and alert SMS level CME ERROR lt err gt Read CRSL CRSL lt level gt The Read command displays the OK current ringer alert SMS sound level setting Test CRSL CRSL list of The Test command displays the supported lt level gt s list of supported sound level settings OK The following table shows the CRSL parameters H3 Family AT Commands User Manual Page 238 of 375 FIDCCON lt Parameter gt Description lt level gt 0 7 Manuf
95. 10 of 375 FIDCCON MIPOPEN 1 3 4 Socket 2 opened OK The following table shows the MIPOPEN parameters lt Parameter gt Description Socket_ID A unique number that identifies a connection Valid socket numbers 1 2 3 and 4 Source_Port Port of source site Port range 1 65535 decimal digits Remote_IP IP IP of the remote site in the format AAA BBB CCC DDD The range of each octet is 0 255 Value can be written in 1 2 or 3 digits Host name The host name convention should meet the rules as describe in RFC 1035 section 2 3 Conventions Syntax is not validated except the maximum length 255 characters Remote_Port Port of remote site Port range 1 65535 decimal digits for outgoing connection Port 0 for incoming connection Protocol Type of protocol stack 0 TCP 1 UDP State 0 Inactive 1 Active Note It s recommended not to use port numbers below 1024 those numbers are reserved for OS use Example AT MIPOPEN 1 1200 123 245 213 012 1234 0 Opening socket 1 using TCP protocol from port 1200 targeting 123 245 213 012 port 1234 AT MIPOPEN 2 1300 123 133 074 192 1242 1 Opening socket 2 using UDP protocol from port 1300 targeting 123 133 074 192 port 1242 H3 Family AT Commands User Manual Page 311 of 375 FIDCCON AT MIPOPEN 1 1222 123 245 213 012 1234 0 Opening socket 1 using TCP protocol from port 1222 targeting 123 245 213 012 port 1234
96. 13 05 22 Update MATONE and MTSM H3 Family AT Commands User Manual Page 2 of 375 FIDCCON V1 1 2 2013 06 18 Change the default value of CBAUD and IPR Add Section 9 1 8 CUBAND command Update XREG command V1 2013 09 12 Update CNMI and CMT Add GTCODECN Update MAPATH Change the default value of S96 Update description of chapter 10 3 Update section 10 3 2 Update the name of the document Add H350 V1 2013 10 23 Add notes that H350 doesn t support GPIO command in section 10 2 9 Add section 12 2 20 V1 2013 12 23 Update CFUN V1 2014 03 10 Add H350 xxx 10 V1 2014 04 03 Add H380 V1 2014 12 26 The company name is changed V1 2015 04 27 Update GTUSIM Update the description of copyright and attention V1 1 10 2015 07 27 Update the logo and the format H3 Family AT Commands User Manual Page 3 of 375 FIDCCON Applicability Type No Type Note 1 H330S 2 H350 3 H380 H3 Family AT Commands User Manual Page 4 of 375 FIDCCON Prefata ae e Ee tere tevetectrperecttettr eereegeterterererert R E rere RN 13 g PTY Fe TUF BRST 0 0 E E et ee EAE E E E 13 WD Target Audiente eienen aeee A AE A EE cutee conesvesass A AEEA A EEN 13 2 Introduction to AT Commands ccecesscessseseseseeseseseseseseesesesescscsceecsescnesacacsesesesenesesesaeseacs
97. 14 MN_SMS_FORW_AVAIL_FAILED 515 MN_SMS_FORW_AVAIL_ABORTED 516 MS invalid TP Message Type Indicator H3 Family AT Commands User Manual Page 372 of 375 FIDCCON 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 MS no TP Status Report in Phase 1 MS no TP Reject Duplicate in Phase 1 MS no TP Reply Path in Phase 1 MS no TP User Data Header in Phase 1 MS missing TP Validity Period MS invalid TP Service Centre Time Stamp MS missing TP Destination Address MS invalid TP Destination Address MS missing Service Centre Address MS invalid Service Centre Address MS invalid alphabet MS invalid TP User Data Length MS missing TP User Data MS TP User Data too long MS no Command Request in Phase 1 MS Cmd Req invalid TP Destination Address MS Cmd Regq invalid TP User Data Length MS Cmd Req invalid TP User Data MS Cmd Req invalid TP Command Type MN MNR creation failed MS CMM creation failed MS network connection lost MS pending MO SM transfer RP Error OK RP Error OK no icon display SMS PP Unspecified SMS rejected By SMS CONTROL H3 Family AT Commands User Manual Page 373 of 375 FIDCCON 15 3 TCP IP Error Parameter Description lt Err gt 2000 TCPIP Param wrong 2001 TCPIP not supported in ppp mode 2002 TC
98. 179521201009511FF0B917962543940F 200080014004 10042004300440045 lt CTRL Z gt CMGW 128 OK AT CMGR 128 CMGR 2 24 079179521201009511FF0B917962543940F 200080014004 10042004300440045 OK AT CMGF 1 OK AT CSDH 1 OK AT CMGR 128 CMGR STO UNSENT 97264593042 145 17 0 8 0 972521100059 145 5 00410042004300440045 OK AT CSMP 25 05 03 15 21 22 23 08 0 0 OK AT CMGW 0544565034 A lt CTRL Z gt H3 Family AT Commands User Manual Page 154 of 375 FIDCCON CMGW 129 OK AT CMGR 129 CMGR STO UNSENT 0544565034 129 25 0 0 05 03 15 21 22 23 08 972521100059 145 1 OK AT CMGF 0 OK AT CMGR 129 CMGR 2 20 079179521201009519FF0A815044650543000050305 1122232800141 AT CMGW 18 gt 0011000c917952428650290004AA044 1424344 SCA is not given CMGW 130 OK AT CMGR 130 CMGR 2 18 079179521201009511000C917952428650290004AA044 1424344 OK AT CMGW 19 gt 079179521201009511000c91 7952428650290004AA0441 424344 Invalid length 19 CMS ERROR invalid PDU mode parameter AT CMGW 19 gt 079179521201009511000c917952428650290004AA044142434477 UDL is not equal to UD length CMS ERROR invalid PDU mode parameter AT CMGW 17 gt 079179521201009501000c9179524286502900040441424344 No VP in PDU message CMGW 131 OK AT CMGR 131 CMGR 2 17 079179521201009501000C917952428650290004044 1424344 OK AT CMGW 14 gt 07917952140230F212000000000c9179524286502900 SMS Command
99. 2 OK AT CPOL CPOL 000 000 IL ORANGE CPOL 001 000 IL Cellcom OK AT CPOL 1 OK AT CPOL CPOL 000 000 IL ORANGE OK 9 1 7 CBAND Change Radio Band This command allows switching from automatic band selection to selection of one or more up to four bands from the following 850 MHz 900 MHz 1800 MHz 1900 MHz Note For H350 xxx 10 H380 this commands is not supported Command Syntax Response Action Set AT CBAND lt band_1 gt OK lt band_2 gt lt band_3 gt lt b or and_4 gt CME ERROR lt err gt H3 Family AT Commands User Manual Page 189 of 375 FIDCCON Read AT CBAND CBAND lt band_1 gt lt band_2 gt lt band_3 gt lt band_4 gt J OK Test AT CBAND CBAND list of supported bands OK The following table shows the CBAND parameters lt Parameter gt Description lt band_1 gt or Automatic band selection entering every time lt band_2 gt or i possible display improbable lt band_3 gt or 850 Selection of 850 MHz band oe 900 Selection of 900 MHz band 1800 Selection of 1800 MHz band 1900 Selection of 1900 MHz band Note This command only for 2G network Example AT CBAND CBAND 900 1800 OK AT CBAND CBAND 0 900 1800 OK AT CBAND 900 OK AT CBAND CBAND 900 OK H3 Family AT Commands User Manual Page 190 of 375 FIDCCON 9 1 8 CUBAND Change 3G Radio Band
100. 2 System Date and Time Access Commands 6 2 1 CCLK Read Set System Date and Time This command reads and sets the H3xx current date time and time zone Command Syntax Response Action Remarks Set CCLK lt time gt OK The Set command sets the date time and o time zone of the system clock CME ERROR Note Set Command sets user defined ai system clock values and saves them in the err gt NVM memory These saved values are kept after power cycle as well Read CCLK CCLK lt time gt The Read command returns the current OK date time and time zone setting or By default lt time gt will represent the CME ERROR network updated time lt err gt If the user has used the Set command once then lt time gt will represent the Set command setting Note If network operator does not support System Clock Update Message the initial date time and time zone displayed by CCLK Read Command could be invalid user s responsibility to set date time and time zone by CCLK Set Command Note See Execute Command for how to enable back network update time Test CCLK CCLK list of The Test command returns valid supported parameters for the CCLK Set command lt time gt s OK H3 Family AT Commands User Manual Page 118 of 375 FIDCCON The following table shows the CCLK parameters lt Parameter gt Description lt time gt ASCII string of format yy MM dd hh mm ss zz or yy MM
101. 20 48 28800 bps V 120 49 38400 bps V 120 50 48000 bps V 120 51 56000 bps V 120 68 2400 bps V 110 or X 31 flag stuffing 70 4800 bps V 110 or X 31 flag stuffing 71 9600 bps V 110 or X 31 flag stuffing 75 14400 bps V 110 or X 31 flag stuffing 79 19200 bps V 110 or X 31 flag stuffing 80 28800 bps V 110 or X 31 flag stuffing 81 38400 bps V 110 or X 31 flag stuffing 82 48000 bps V 110 or X 31 flag stuffing 83 56000 bps V 110 or X 31 flag stuffing this setting can be used in conjunction with asynchronous non transparent UDI or RDI service in order to get FTM 84 64000 bps X 31 flag stuffing this setting can be used in conjunction with asynchronous non transparent UDI service in order to get FTM 115 56000 bps bit transparent 116 64000 bps bit transparent 120 32000 bps PIAFS32k 121 64000 bps PIAFS64k 130 28800 bps multimedia 131 32000 bps multimedia 132 33600 bps multimedia H3 Family AT Commands User Manual Page 76 of 375 FIDCCON 133 56000 bps multimedia 134 64000 bps multimedia The default value is 7 lt name gt 0 Data circuit asynchronous UDI or 3 1 kHz modem The default value is 0 1 data circuit synchronous UDI or 3 1 KHz modem 4 data circuit asynchronous RDI 5 data circuit synchronous RDI lt ce gt 0 Transparent 1 Non transparent default 2 both transparent preferred 3 both non transparent p
102. 255 255 0 255 0 0 65535 65535 0 0 65535 65535 00000000 ffffffff 0 0 255 255 00000 00000 OK H3 Family AT Commands User Manual Page 304 of 375 FIDCCON 12 2 19 MGAUTH Set type of authentication This command allows to enter the type of authentication for a user name using a password for the specified PDP context Command Syntax Response Action Set AT MGAUTH lt cid gt lt auth gt lt name gt lt p OK wd gt or CME ERROR lt err gt Read AT MGAUTH MGAUTH lt cid gt lt auth gt OK Test AT MGAUTH MGAUTH 1 10 0 2 64 64 OK The following table shows the MGAUTH parameters Parameter Description cid PDP context identifier must be defined by AT CGDCONT firstly Range from 1 10 auth Authentication may be 0 Meaning authentication protocol not used NONE 1 Meaning personal authentication protocol PAP 2 Meaning handshake authentication protocol CHAP name User name as string with length pwd Password as string with maximum length Example at mgauth 1 1 gsm 1234 OK H3 Family AT Commands User Manual Page 305 of 375 FIDCCON at mgauth MGAUTH 1 1 OK 12 2 20 CGEV Unsolicited Packet Domain Event Reporting This unsolicited event is sent by the H3xx to the terminal for packet domain event reporting The following table shows the format and parameters of CGEV lt Parameter gt Description
103. 3 8 Data 1 Stop default can be set only with lt parity gt 4 7 8 Data 1 Parity 2 Stop can be set with lt parity gt of 0 or 1 lt parity gt Determines how the parity bit is generated and checked if present 0 Odd 1 Even 4 No parity default Example AT ICF ICF 3 4 OK AT ICF ICF 1 3 7 0 1 4 OK AT ICF 3 4 OK H3 Family AT Commands User Manual Page 212 of 375 FIDCCON 10 2 Other Parameter Commands 10 2 1 CBC Battery Charger Connection This command is used for user to query the battery voltage level Command Syntax Response Action Read CBC CBC lt bcs gt lt bcl gt OK The following table shows the CBC parameters lt Parameter gt Description lt bcs gt Battery status value 0 Battery powered 1 Externally powered not implemented in H3xx Note The H3xx input power source is connected via the battery pins only so it is always battery powered lt bcl gt VBAT voltage value A decimal number represents the digital value The input level is multiplied by 1000 Note H3xx does not support the usage of battery power detect The power supply of H3xx is connected via the battery pins However users can use this command to verify the level of H3xx input power source Example AT CBC CBC 0 3802 OK H3 Family AT Commands User Manual Page 213 of 375 FIDCCON 10 2 2 CFUN Shut Down Phone Functionality This command shuts dow
104. 321 of 375 FIDCCON 13 7 GTSET Set receive data mode Command Syntax Response Action Set GTSET lt ParamName gt lt value gt lt value1 gt OK or ERROR The following table shows the GTSET parameters related HEX mode lt Parameter gt Description lt ParamName gt SENDTIME Set the auto push timeout See description of lt value gt below lt value gt 1 30 seconds The default value is 12 lt ParamName gt IPRFMT The format of reiceived data See description of lt value gt below lt value gt 0 Reiceived data with MIPRTCP and the data is incode 1 Reiceived data only and the data is without incode In received character string 2 Reiceived data format is lt CR gt lt LF gt MIPRTCP sid len data and the data is without incode 3 Reiceived data format is lt CR gt lt LF gt MIPRTCP sid len lt CR gt data and the dat is without incode The default value is 0 lt value1 gt 0 ending with lt CR gt lt LF gt 1 ending without lt CR gt lt LF gt The default value is 0 Example Opening socket 2 already H3 Family AT Commands User Manual Page 322 of 375 FIDCCON AT GTSET IPRFMT 0 0 OK AT MIPSEND 2 10 gt 0123456789abc OK MIPPUSH 2 0 MIPSEND 2 0 2048 OK lt CR gt lt LF gt MIPRTCP 2 0 30313233343536373839 lt CR gt lt LF gt Same as basic mode AT GTSET IPRFMT 1 0 OK A
105. 4800 9600 19200 38400 57600 115200 230400 460800 921600 bits per second according to the parameters of the IPR command Using AT IPR lt rate gt with a lt rate gt value other than 0 1 or 9 disables the auto baud rate detection feature The entered baud rate is stored in H3xx and is restored after power up The H3xx auto baudrate detect supports the next baudrates 1200 2400 4800 9600 19200 38400 57600 115200 230400 Note IPR is similar to CBAUD but has the alility to save after power down Command Syntax Response Action Set IPR lt n gt OK PR lt rate gt or CME ERROR lt err gt Read IPR IPR lt rate gt OK Test PR IPR list of supported lt rate gt s OK Note Read mode returns the current baud rate rather than the value that was set by Set Mode The following table shows the IPR parameters lt Parameter gt Description lt n gt lt rate gt 0 Auto baud rate 1 Auto baud rate 2 300 3 1200 4 2400 H3 Family AT Commands User Manual Page 205 of 375 FIDCCON 5 4800 6 9600 7 19200 8 38400 9 Auto baud rate 10 57600 11 115200 12 230400 13 460800 14 921600 The default value is 115200 Note The platform we use supports more than 14 baudrates those has been listed above but the high speed baudrate is hard to test we can not make sure it can be support or not so
106. 5 FIDCCON return to the user as an unsolicited response 0 operation fails 1 operation success Read FTPDEL ERROR Not supported Test FTPDEL FTPDEL lt file Return command format name gt OK The following table shows the FTPDEL parameter lt Parameter gt Description File name The file name need to be deleted string the max length is 255 octets Example AT FTPDEL 1234 txt FTPINFO DELE 1234 txt OK FTPINFO 250 Delete operation successful FTPDEL 1 14 11 FTPREN Rename File This command is used for rename the file or folder of current directory Command Syntax Response Action Remarks Set FTPREN lt file_ name_from gt lt file_name_to gt OK FTPREN lt result gt or ERROR lt error_code gt lt file_name_from gt indicates the file need to be named lt file_name_to gt indicates the file after named The command execution result return to the user as an unsolicited response 0 operation fails H3 Family AT Commands User Manual Page 354 of 375 FIDCCON 1 operation success Read FTPREN ERROR Not supported Test FTPREN FTPREN lt file name from gt lt file name to gt OK Return command format The following table shows the FTPREN parameters lt Parameter gt Description File name from Old
107. 5 FIDCCON supported lt n gt s OK The following table shows the COLP parameters lt Parameter gt Description lt n gt Sets displays the result code presentation status of the H3xx O Disable default 1 Enable lt m gt Displays the subscriber s COLP service status in the network 0 COLP not provisioned 1 COLP provisioned 2 Unknown for example no network and so on lt number gt Sets the phone number using the format specified by lt type gt lt type gt Sets the address octet type in integer format refer to GSM 04 08 subclause10 5 4 7 129 Unknown 145 International used when dialing string includes international access code character lt subaddr gt Sets the subaddress using the format specified by lt satype gt lt satype gt Sets the address octet type in integer format refer to GSM 04 08 subclause 10 5 4 8 Example AT COLP 0 OK AT COLP 2 CME ERROR operation not supported H3 Family AT Commands User Manual Page 106 of 375 FIDCCON 6 Phone Book and Clock 6 1 Directory Access Commands Phone Book This set of commands enables read write access to the phone book contained within the H3xx including both the numeric and the alpha information contained in the location The presentation is according to GSM 07 07 In some cases it may be possible to use these commands to access the dialed and received call stacks However as these phone
108. 75 FIDCCON 10 6 2 BODYSARWCDMA Set Max Tx Power Threshold For WCDMA This command is used to set the max tx power threshold for WCDMA Test command can query the supported parameter list And the default value is the maximum one Read command can query the current threshold Set command can set the threshold the value is volatile and the parameter range is 9dbm For WCDMA850 900 1900 2100 the default value is 20dbm All bands parameters should be set no matter they are supported or not And it will not take effect for those bands which are not supported Command Syntax Response Action Remarks Set BODYSARWCDMA OK lt PWR1 gt lt PWR2 gt or lt PWR3 gt lt PWR4 gt ERROR Read BODYSARWCDMA BODYSARWCDMA lt PWR1 gt lt PWR2 gt lt P WR3 gt lt PW R4 gt OK Test BODYSARWCDMA BODYSARWCDMA I ist of supported lt PWR1 gt lt P WR2 gt lt PW R3 gt lt PWR4 gt s OK The following table shows the BODYSARGSM parameters lt Parameter gt Description lt PWR1 gt Threshold for WCDMA850 dBm lt PWR2 gt Threshold for WCDMA900 dBm H3 Family AT Commands User Manual Page 235 of 375 FIDCCON lt PWR3 gt Threshold for WCDMA1900 dBm lt PWR4 gt Threshold for WCDMA2100 dBm Example AT BODYSARWCDMA BODYSARWCDMA 15 23 15 23 15 23 15 23 OK H3 Family AT Commands User Manual Page 199 of 314 AT BODYSARWCDMA
109. CCON 665723F633D505245462533443A544D253344313131393531343833323A5325334467384A63763 1 MIPRTCP 2 0 426A5458472D30636A5926616D703B707265763D2F223E686572653C2F 41 3E2E0DOA3C2F4 24F44593 E3C2F48544D4C3E0D0A MIPSTAT 2 1 40 13 14 MPING Start Ping Execution ICMP Protocol This command allows verifying IP connectivity to another remote machine computer by sending one or more Internet Control Message Protocol ICMP Echo Request messages The receipt of corresponding Echo Reply messages are displayed along with round trip times Valid IP address must be obtained using AT MIPCALL command prior to starting ping execution Only one ping request execution will be allowed at any given moment Command Syntax Response Action Remarks Set MPING lt m OK The set command shall send a lt count gt ode gt lt Desti r Internet Control Message Protocol ICMP nation_IP ho Echo Request CME ERROR lt err gt sname se Messages to a target node defined by ounti saze lt Destination IP hostname gt parameter L lt TTL gt lt TO S gt lt TimeOu If lt mode gt is equal 0 no parameters trailing gt J lt mode gt parameter are allowed otherwise ERROR message will be reported to DTE If lt mode gt is equal 0 MS will abort sending Echo Request messages if ping request is in process otherwise ERROR message will be reported to DTE Unsolicited MPING The receipt of corresponding ICMP Echo Reply Respo
110. CGDSCONT H3 Family AT Commands User Manual Page 303 of 375 FIDCCON commands lt packet filter identifier gt Numeric parameter value range from 1 to 8 lt source address and subnet mask gt Consists of dot separated numeric 0 255 parameters on the form a1 a2 a3 a4 m1 m2 m3 m4 for lpv4 and al a2 a3 a4 a5 a6 a7 a8 a9 a10 a11 a12 a13 a14 a15 a16 m1 m2 m3 m4 m5 m6 m7 m8 m9 m10 m11 m12 m13 m14 m15 m16 for Ipv6 lt protocol number ipv4 next header ipv6 gt Numeric parameter value range from 0 to 255 lt destination port range gt Consists of dot separated numeric 0 65535 parameters on the form f t lt source port range gt Consists of dot separated numeric 0 65535 parameters on the form f t lt ipsec security parameter index spi gt Hexadecimal parameter value range from 00000000 to FFFFFFFF lt type of service tos ipv4 and mask traffic class ipv6 and mask gt Dot separated numeric 0 255 parameters on the form t m lt flow label ipv6 gt Hexadecimal parameter value range from 00000 to FFFFF Valid for Ipv6 only lt evaluation precedence index gt Numeric parameter value range from 0 to 255 Example AT CGTFT CGTFT 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00000000 0 0 00000 AT CGTFT CGTFT IP 1 8 0 255 0 0 0 0 0 0 0 0 255 255 255 255 255 255
111. D already in it 72 USC2 16 bit 68 8 bit Each other value except of 96 80 and 240 are 7 bit Not supported values are 96 80 240 The default value is 15 7 bit lt m gt 0 No further user action required network initiated US SD Notify or no further information needed after mobile Initiated operation 1 Further user action required network initiated USSD Request or further information needed after mobile initiated operation 2 USSD terminated by network the reason for the termination is indicated by the index as described in CUSD Termination Cause Table Index 3 Other local client has responded 4 Operation not supported 5 Network time out CUSD Termination Cause Table Index Termination Cause Index NO_CAUSE 0 CC_BUSY 1 PARAMETER_ERROR 2 H3 Family AT Commands User Manual Page 101 of 375 FIDCCON INVALID NUMBER 3 OUTGOING_CALL_BARRED 4 TOO_MANY_CALLS_ON_HOLD 5 NORMAL 6 DROPPED 10 NETWORK 12 INVALID_CALL_ID 13 NORMAL_CLEARING 14 TOO_MANY_ACTIVE_CALLS 16 UNASSIGNED_ NUMBER 17 NO_ROUTE_TO_DEST 18 RESOURCE_UNAVAILABLE 19 CALL_BARRED 20 USER_BUSY 21 NO_ANSWER 22 CALL_REJECTED 23 NUMBER_CHANGED 24 DEST_OUT_OF_ORDER 25 SIGNALING_ERROR 26 NETWORK_ERROR 27 NETWORK _BUSY 28 H3 Family AT Commands User Manual Page 102 of 375 FIDCCON
112. DS lt fo gt lt mr gt lt ra gt lt tora gt lt scts gt lt dt gt lt st gt lt CR gt lt LF gt In PDU mode CMGF 0 CDS lt length gt lt CR gt lt LF gt lt pdu gt The following table shows the CDS parameters lt Parameter gt Description lt fo gt First octet of the SMS lt mr gt Message Reference lt ra gt Message Recipient address lt tora gt Type of Recipient address H3 Family AT Commands User Manual Page 142 of 375 FIDCCON lt scts gt Service center time stamp lt dt gt Discharge Time lt st gt Status After sending a CDS unsolicited response to the TE the H3xx will expect a CNMA new message acknowledgement from the TE within a predefined timeout of 15 seconds Within the timeout the H3xx will not send another CDS unsolicited response to the TE before the previous one is acknowledged If the CDS is acknowledged within the timeout the new SMS is not saved in the message storage If the H3xx does not receive acknowledgment within the required time CNMI parameters will NOT be reset automatically and the CDS unsolicited response will send to the TE again Example AT CMGF 1 OK AT CSMP 49 167 OK AT CSMP CSMP 49 167 0 0 OK AT CNMI 1 0 0 1 OK AT CMGS 052468000 gt Hello CMGS 187 OK CDS 6 187 97252468000 145 05 08 03 08 56 34 08 05 08 03 08 56 34 08 70 AT CNMA OK H3 Family AT Commands User Manual Pag
113. EC SIM emergency call codes phonebook read only AP Selected application phonebook BN SIM barred dialling number phonebook only valid with PIN2 SN SIM service dialling number phonebook The default phone book is SM lt used gt Integer type value indicating the number of used locations in the selected memory lt total gt Integer type value indicating the total number of entries in the selected phone book memory lt pin2 gt String type PIN2 password 4 8 digits Example H3 Family AT Commands User Manual Page 108 of 375 FIDCCON AT CPBS SM OK AT CPBR CPBS SM FD SN LD ON EC BL OK AT CPBR 1 OK AT CPBR 1 3 There is nothing written in entry 1 2 3 OK AT CPBS FD lt correct pin2 gt OK CPBW pin2 unlocked AT CPBW 1 034546565 129 xyz Write into FD storage OK AT CPBS FD lt wrong pin2 gt CME ERROR incorrect password AT CPBS FD lt pin2 longer then 8 chars gt CME ERROR text string too long 6 1 2 CPBR Read Phone Book Entries This command recalls phone book entries from a specific entry number or from a range of entries If only one entry is specified and that entry is empty OK is returned If a range of entries is requested all entries that contain data within that range are returned If a listing fails in a H3xx error CME ERROR lt err gt is returned This command can also be used to obtain inf
114. ERIT Otara naan binasakan 2 OTA CENIT CARA RAKE rAnnnaA For fault tolerance Two mode can be trade off lt oa da gt Original destination address lt data gt Message contents in text mode In PDU mode Size of message in octets excluding SMSC data INTEXT lt length gt mode Number of characters included in lt data gt Message header and contents in PDU mode format See description in ee CMGR Read Message lt toda toda gt Type of origination address destination address lt fo gt First octet of the SMS lt mr gt Message Reference lt ra gt Recipient Address lt tora gt Type of Recipient address lt scts gt Service center time stamp lt ct gt Command type lt sn gt Message serial number lt mid gt Message ID lt page gt Current page number lt pages gt Total number of pages Page 146 of 375 FIDCCON lt dt gt Discharge Time lt st gt Status Example AT CMGL CMGL REC UNREAD REC READ STO UNSENT STO SENT ALL OK AT CPMS SM _ read messages from SIM CPMS 2 20 11 61 2 20 OK AT CMGL read rec unread messages with changing message stat CMGL 1 REC UNREAD 972544565034 05 01 01 09 21 22 08 message text OK AT CMGL OK the message stat was changed No rec unread messages AT CPMS ME CPMS 11 61 11 61 2 20 OK AT CMGL sto sent CMGL 142 STO SENT 054565034 message text OK AT CSDH 1 OK AT CMGL STO SENT CMGL 142
115. Echo Reply message that corresponds to a sent Echo Request message measured after Echo Request message was sent If the Echo Reply message is not received within the time out MPINGSTAT The following table shows the MPING unsolicited response parameters lt Parameter gt Description lt Destination_IP gt Specifies the message sender machine computer which is identified by IP address 4 octets long in dotted decimal notation Each octet of IP address has valid value range of 0 to 255 The message sender machine computer may be either the target of Echo Requestmessage if a response was an Echo Reply message or a gateway router in a path of Echo Request message passage for any other H3 Family AT Commands User Manual Page 334 of 375 FIDCCON ICMP response message lt type gt The first octet of the ICMP header is a ICMP type field which specifies the format of the ICMP message Referto IETF RFC 792 for lt type gt valid values lt code gt The reasons for the non delivery of a packet are described by code field value of ICMP header Every lt type gt has its own defined lt code gt values Refer to IETF RFC 792 for lt code gt valid values lt RTT gt Specifies Round Trip Time RTT measured in milliseconds This parameter will be reported in command response only if Echo Reply message was received Note Ping request is being executed from the moment
116. FC 1 3 0545658278 129 1 Register UC forward to of all classes OK AT CCFC 1 1 Activate UC forward to of all classes OK AT CCFC 1 2 nterrogate reason not reachable of all classes CCFC 1 1 97254151200 145 CCFC 0 2 0 CCFC 0 4 0 OK For lt reason gt 3 forward only voice calls is activated AT CCFC 4 2 Interrogate reason all call forwarding for all classes CME ERROR no network service Interrogation of lt reason gt 30 is not supported by network AT CCFC 2 3 972545658278 OK AT CCFC 2 0 Disable call forwarding for reason no reply of all classes OK H3 Family AT Commands User Manual Page 71 of 375 FIDCCON AT CCFC 2 2 CCFC 0 1 972545658278 145 25 CCFC 0 2 972545658278 145 25 CCFC 0 4 972545658278 145 25 OK 5 3 13 CLIR Calling Line Identification Restriction This command instructs the H3xx to query enable or disable the presentation of the CLI calling line ID of a MO call to the called party The restriction of the CLI disable presentation is dependent both on the H3xx and on the network The network enables three possible provisions of CLIR Not provisioned CLIR Off presentation allowed Provisioned permanently Provisioned with Temporary mode The provision is fixed and cannot be changed by an AT command Temporary Mode Temporary mode can be in one of two states A Presentation restricted CLIR On as default B Presentation allowed CLIR
117. FIDCCON Perfect Wireless Experience FETC AS H3 Family AT Commands User Manual Version V1 1 10 Date 2015 07 27 Copyright Copyright 2015 Fibocom Wireless Inc All rights reserved Without the prior written permission of the copyright holder any company or individual is prohibited to excerpt copy any part of or the entire document or transmit the document in any form Attention The document is subject to update from time to time owing to the product version upgrade or other reasons Unless otherwise specified the document only serves as the user guide All the statements information and suggestions contained in the document do not constitute any explicit or implicit guarantee Trademark FIDCCON The trademark is registered and owned by Fibocom Wireless Inc Versions Version Date Remarks V1 0 0 2012 05 30 Initial Version V1 0 1 2012 06 29 Update product model name V1 0 2 2012 07 31 Update any items IPR UART2 etc Update description in chapter14 6 2 and 14 6 3 V1 0 3 2012 11 24 Delete GTEINT command update mci mcell command V1 0 4 2012 12 13 Add chapter 16 PCM Command V1 0 5 2013 01 04 Update the name of this document V1 0 6 2013 01 10 Add XREG V1 0 7 2013 01 23 Update CMUX command V1 0 8 2013 03 06 Change the default value of cbaud and ipr to 0 V1 0 9 2013 04 25 Update GTSET command descriptions V1 1 0 2013 05 10 Delete PS PN PU PP PC in section 8 1 5 V1 1 1 20
118. Family AT Commands User Manual Page 349 of 375 FIDCCON 14 6 FTPMKD Make Directory This command is used for creating a specified directory in a path name for absolute path name or subdirectory of current working directory for relative path name Command Syntax Response Action Remarks Set FTPMKD lt direc OK FTPMKD lt result gt lt directory_name gt parameter is the tory_name gt Or ERROR directory name need to be created The lt error_code gt command execution result return to the user as an unsolicited response 0 operation fails 1 operation success Read FTPMKD ERROR Not supported Test FTPMKD FTPMKD lt directory Returns command format name gt OK The following table shows the FTPMKD parameter lt Parameter gt Description Directory name The name of file directory need to be created string the max length is 254 octets Example AT FTPMKD 1234 OK FTPMKD 1 H3 Family AT Commands User Manual Page 350 of 375 FIODCCON 14 7 FTPRMD Remove Directory This command is used for removing a specified directory in a path name for absolute path name or subdirectory of current working directory for relative path name Command Syntax Response Action Remarks Set FTPRMD lt d OK FTPRMD lt directory_name gt parameter consistes irectory_name lt result gt Or ERROR ofdirectory path or subdirectory of current gt lt err
119. H ARFCN 00536 BSIC 056 RxLev 037 Cell ID 03583 PD TCH ARFCN INVALID_ARFCN Timeslot 00 CBA 000 CBQ 000 T3314 00 AT MCELL 0 19 OK MCELL GPRS Parameters P BCCH ARFCN 00536 BSIC 056 RxLev 039 Cell ID 03583 PD TCH ARFCN INVALID_ARFCN Timeslot 00 BS_PA_MFRMS 02 BS_AG_BLK_RES 01 BS_PAG_BL K_RES 0 BS_PBCCH_BLOCKS 1 H3 Family AT Commands User Manual Page 197 of 375 FIDCCON 9 1 11 MCI H3xx Cell Information This command only support when module register GSM net UMTS not supported This command returns neighbor cell information The command returns ARFCN BSIC and RX level of serving and adjacent cells In case H3xx is registered adjacent cells are from registered PLMN In case H3xx is in Emergency Mode adjacent cells are physical neighbors BSIC is displayed only in case SCH Synchronization Channel is decoded The parameter lt enable_TA gt determines whether lt TA gt will be reported by MCI command lt TA gt is defined for serving cell only This value will be displayed only in Dedicated mode The command output is lt Filter gt dependent In case the command output should be filtered to include just cells of a specific GSM band one or more the filter parameter should be set accordingly The filtering will apply to the neighbor s cells only the serving cell info will always be returned Using the set command without a parameter will return output according to the currently set lt Filter gt v
120. H3xx to port_speed gt lt N1 gt lt T open the MUX stack 1 gt lt N with various 2 gt lt T2 gt lt T3 gt lt k gt parameters This Il command works only in PREMUX state Read CMUX CMUX lt mode gt The Read command lt subset gt displays the current lt port_speed gt lt N1 gt mode and settings This lt T1 gt lt N2 gt command works only in MUX state lt T2 gt lt T3 gt lt K gt CME ERROR lt err gt Test CMUX CMUX list of The Test Command displays a list of supported modes and parameters This command works in both PREMUX and MUX states H3 Family AT Commands User Manual Page 229 of 375 FIDCCON of supported lt k gt s The following table shows the CMUX parameters lt Parameter gt Description lt mode gt MUX mode 0 Basic lt subset gt Defines how the MUX control channel is set up The virtual channel is set up according to this setting 0 UIH frames used only lt port_speed gt 1 9600 bit sec 2 19200 bit sec 3 38400 bit sec 4 57600 bit sec 5 115200 bit sec default 6 230400 bit sec 7 1 Mbit s lt N1 gt Maximum frame size 1 1509 The default value is 31 in Basic mode lt T1 gt Acknowledgement timer in units of 10 ms 1 255 The default value is 10 100 ms lt N2 gt Maximum number of retransmissions 0 5 The default value is 3 lt T2 gt Response timer for the DLCO in unit of 10
121. IC MIC Default 2 2nd channel AUXI AUXI Audio channel output from H3xx 1 1st channel SPK SPK Default 2 2nd channel AUXO AUXO 3 Both 1st and 2nd Example at gtcodecn 0 OK at mapath MAPATH 1 1 OK att mapath 1 2 OK at mapath MAPATH 1 1 2 OK at gtcodecn 2 OK at mapath MAPATH 1 1 MAPATH 2 1 OK ALC5621 codec Swith to 2 4 audio channel CS42L73 codec H3 Family AT Commands User Manual Page 247 of 375 FIDCCON at mapath 1 2 Swith to 2 audio channel OK at mapath 2 2 OK at mapath MAPATH 1 2 MAPATH 2 2 OK at mapath MAPATH 1 2 1 2 1 2 3 OK 11 2 11 MAVOL Volume Setting This command enables you to determine a volume level for a particular feature via a particular accessory The gain levels are saved in NVM Therefore upon power up the path active mic speaker and alert speaker will have these saved gain levels Note The SMS MT volume is adjusted using the MAVOL command with type ring The RING value is related to the SMS alert the MT call and so on Note For H350 xxx 10 this commands is not supported Command Syntax Response Action Remarks Set MAVOL lt ac OK The Set command sets the cy gt lt feature gt r volume level lt n gt to a lt vol gt certain lt feature gt through a certain CME ERROR lt err gt lt accy gt Read MAVOL Current path volume The Read command returns the
122. K AT CREG 0 OK 9 1 4 CGREG GPRS Network Registration This command gives the information of state of GPRS network registration Command Syntax Response Action Remarks Set AT CGREG lt n OK The Set command controls the gt bi presentation of an unsolicited result code CGREG and the result of CME ERROR lt err gt the Read operation Read AT CGREG CGREG The Read command returns the lt n gt lt stat gt lt lac gt lt ci gt status of the result code presentation H3 Family AT Commands User Manual Page 179 of 375 FIDCCON lt AcT gt lt rac gt and shows whether the network has OK currently indicated the GPRS registration of the H3xx Location information elements lt lac gt and lt ci gt are returned only when lt n gt 2 and the H3xx is registered in the network Test AT CGREG CGREG list of The Test command displays the supported lt n gt s supported values of lt n gt OK The following table shows the CGREG parameters lt Parameter gt Description lt n gt 0 Disables the network registration unsolicited result code 1 Enables the network registration unsolicited result code CGREG lt stat gt 2 Enables the network registration and location information in unsolicited result code and Read command CGREG lt stat gt lt lac gt lt ci gt The default value is 0 lt stat gt 0 Not registered and the ME i
123. L refers to a single or MTPY call Asingle Active call is considered a MTPY call with one call index numbered as 1 Command Response Action CHLD lt n gt If the call is terminated OK approve request was submitted NO CARRIER If the call state is changed link split from active to hold and so on OK approve request was done If the call is terminated and another call is answered OK call answered and is now connected NO CARRIER Command Syntax Response Action Remarks Test CHLD CHLD list of supported The Test command returns lt n gt values lt n gt s supported by the H3xx to the terminal OK The following table shows the CHLD parameters Parameter n Description 0 Release all held calls or set User Determined User Busy for a waiting incoming H3 Family AT Commands User Manual Page 67 of 375 FIDCCON call if both exists then only the waiting call will be rejected Releases all active calls and accepts the held or waiting call Note In the scenario An active call a waiting call and held call when the active call is terminated we will make the Waiting call as active Release a specific call x specific call number as indicated by CCLC Place all active calls if exist on hold and accepts the other call held or waiting incoming If only one call exists which is active place it on hold and if only held call exists make it ac
124. LCC 1 1 6 0 0 0545550099 129 5 6 3 COLP Connected Line Identification Presentation This command relates to the GSM supplementary service called COLP Connected Line Identification Presentation which enables a calling subscriber to obtain the connected line identity COL of the called party after setting up a mobile originated call with the H3xx For example after setting up a mobile originated call to one number that is forwarded to another number the calling party will see the number of that third party When this command is enabled and the called subscriber permits it the following intermediate result code is returned COLP lt number gt lt type gt lt subaddr gt lt satype gt Note This command is activated when COLP is supported by the network Command Syntax Response Action Remarks Set COL OK The Set command enables disables the P lt n CME ERROR display of the COL at the TE on the H3xx It gt Zeige has no effect on the execution of the COLR supplementary service on the network The value set by this command is not retained after a power cycle Read COL COLP lt n gt lt m gt The Read command displays the status of P OK lt n gt It also initiates a query of the COLP service provision status and displays lt m gt Test COL The Test command displays the supported P COLP list of values of lt n gt H3 Family AT Commands User Manual Page 105 of 37
125. Manual Scope This manual introduces the H3xx AT command set and describes how software developers can use these commands to communicate with the H3xx device and to create software applications that communicate with the H3xx using these commands Note The integrator should read the corresponding SW release notes for the H3xx version he is using to get information about differences from this manual 1 2 Target Audience This manual is intended for software developers who communicate with the H3xx device using the AT commands and create applications to communicate with the H3xx device using the AT commands H3 Family AT Commands User Manual Page 13 of 375 FiDCCON 2 Introduction to AT Commands 2 1 AT Commands Overview AT commands are sets of commands used for communication with the H3xx cellular modem AT commands are comprised of assemblies of ASCII characters which start with the AT prefix except the commands A and The AT prefix is derived from the word Attention which asks the modem to pay attention to the current request command AT commands are used to request services from the H3xx cellular modem such as Call services dial answer and hang up Cellular utilities send receive SMS Modem profiles Auto Answer Cellular Network queries GSM signal quality 2 2 General System Abbreviations The basic system configuration contains a modem and a terminal The H3xx is the modem and may be referred to as
126. OK AT CGDSCONT 1 1 ERROR AT CGDSCONT 2 1 1 3 OK AT CGDSCONT CGDSCONT 2 1 1 3 OK AT CGDSCONT CGDSCONT 1 20 IP 0 2 0 1 2 3 4 CGDSCONT 1 20 IPV6 0 2 0 1 2 3 4 OK 12 2 17 CGEREP Packet Domain Event Reporting This command is used to enable or disable sending of unsolicited result codes CGEV XXX from MT to TE in the case of events occurring in the Packet Domain Command Syntax Response Action Remarks Set CGEREP lt mo OK The Set command enables or disables de gt lt bfr gt sending of unsolicited result codes CGEV XXX from MT to TE in the case of certain events occurring in the Packet Domain MT or the network Read CGEREP CGEREP lt mode gt The read command returns the current lt bfr gt value of lt mode gt and lt bfr gt parameters OK Test CGEREP CGEREP list of The test command lists the supported supported values for lt mode gt and for lt bfr gt lt mode gt s list of supported lt bfr gt s OK H3 Family AT Commands User Manual Page 299 of 375 FIDCCON The following table shows the CGEREP parameters lt Parameter gt Description lt mode gt 0 buffer unsolicited result codes in the MT if MT result code buffer is full the oldest ones can be discarded No codes are forwarded to the TE 1 discard unsolicited result codes when MT TE link is reserved e g in on line data mode otherwis
127. OK MCI 712 33 93 97 255 110 110 255 110 112 255 110 AT MCI 2 0 OK MCI 712 33 93 97 255 110 110 255 110 112 255 110 AT MCI MCI 1 15 0 1 OK H3 Family AT Commands User Manual Page 200 of 375 FIDCCON 9 1 12 GTRAT Selection of Radio Access Technology This command forces the selection of the Radio Access Technology RAT in the protocol stack On a later network registration COPS CGATT this RAT is used This command is available for phones supporting Dual Mode In case of GSM UMTS Dual Mode is selected additionally a preferred RAT can be configured which is stored in NVRAM selecting which RAT shall be attached first Note Dual mode means GSM and UMTS Access Technology will be active and full InterRAT measurements and handovers are provided e Set command is used to set RAT and proffered RAT value used for further network registration at cops 0 e Read command returns the previously set of lt Act gt and lt PreferredAct gt values e Test command returns the range of supported lt Act gt and lt PreferredAct gt values Command Syntax Response Action Remarks Set AT GTRAT lt AcT gt OK or Sr ietenegnct CME ERROR lt error gt Read AT GTRAT GTRAT lt Act gt lt PreferredAct gt OK Test AT GTRAT GTRAT 0 2 0 2 Note i e list of supported OK lt Act gt s and list supported lt PreferredAct gt s Defined values lt AcT gt indicate
128. OM cesscscscepesteatsestterbeteas heel elecahdesanetestis Haavataseatse nena a eE E aare EEA N a a A AEE aiia 344 14 2 FTPOPEN Open a FTP Connection with FTP Servet ccccessssesesscsseseseneeseeeesesseseeseseeeeseeeeaes 344 14 3 FTPCLOSE Close Established FTP Connetion ccccccccccsescesesseseeseseseesceeseseeseseeseseneeeeneseesesseeees 346 14 4 FTPINFO FTP Unsolicited Indication Enable Disable ee eceeesceeeceeseseeeseceseeeeeeseeeseeeeeeseeneees 347 14 5 FTPCWD Change Working DireCtory cc cccccccccscsscssesecscesecseeseesesecssesscseesecsesseesescescsecsecsesseeaeeas 349 14 6 FTPMKD Make Directory cceccecescceseseesceceeseeceeenecseenesaecseseeseceeesesaessesaesaescesaesessaeaessesaesaeeesenseeeneeas 350 H3 Family AT Commands User Manual Page 11 of 375 FIDCCON 14 7 FTPRMD Remove DIreCtOry c cee ccccccsssessesscessesscesccsscescsseeesessesesesscsssessesseessessescsesseseeeseseesseeseasees 351 14 8 FTPPWD Print Working DireCtory cccececeeseesceseseeeceseesceceesesececeneeaecseaececeaeseceeesesaesaesaesaeeeeeateneees 352 14 9 FTPCDUP Change Directory Up ccc cccsccscsscssessceesecseeseesesscssesecseesecsecscesenecsacsecsecsecseceeeaseesseses 352 14 10 FTPDEL Delete the File ce eeeesseceseceeeseesesecessesseceecssscecesssessscececessscseeseasscseecaeeeeeeseeeaeesseenees 353 14 11 FTPREN Rename File cc ceccccccccccesceseesceseseeseesecseeeesaescesaesececnacesecesaeseseceaecaessesae
129. OR The Test command for Z is not defined and therefore is not supported by the H3xx The H3xx returns an error The following table shows the Z parameters lt Parameter gt Description lt value gt 0 Set to user profile 0 1 Set to user profile 1 The default value is 0 Example ATZO OK H3 Family AT Commands User Manual Page 35 of 375 FIDCCON 4 1 11 amp W Store User Profile This command saves in internal memory from the active profile to one of two user profiles Note The user must power off the module in regular process Otherwise this command cannot be in effect For H350 xxx 10 H380 this command is not supported Command Syntax Response Action Remarks Set amp W lt n gt OK Set command stores the current active r configuration to user profile O or 1 CME ERROR lt err gt The following table shows the amp W parameters lt Parameter gt Description lt n gt User s profile number 0 Store to user s profile 0 1 Store to user s profile 1 Example AT amp WO OK AT amp W 1 OK H3 Family AT Commands User Manual Page 36 of 375 FIDCCON 4 1 12 amp Y Default User Profile This command decides which user profile will be used after a power up cycle Note For H350 xxx 10 H380 this command is not supported Command Syntax Response Action Set amp Y lt n gt OK or CME ERROR lt err gt The
130. P1 00 denoting the current record lt P3 gt Length 0 255 GET RESPONSE lt P1 gt 00 lt P2 gt 00 lt P3 gt Length 0 255 UPDATE BINARY lt P1 gt Offset high 0 255 lt P2 gt Offset low 0 255 lt P3 gt Length 0 255 UPDATE RECORD lt P1 gt Rec No 0 255 lt P2 gt Mode 02 next record 03 previous record 04 absolute mode current mode the record number is given in P1 with H3 Family AT Commands User Manual Page 39 of 375 FIDCCON P1 00 denoting the current record lt P3 gt Length 0 255 STATUS lt P1 gt 00 lt P2 gt 00 lt P3 gt Length 0 255 lt data gt lt pathid gt Information which shall be written to the SIM hexadecimal character format Man datory for UPDATE BINARY and UPDATE RECORD String type contains the path of an elementary file on the SIM USIM in hexadecimal format as defined in ETSI TS 102 221 60 e g 7F205F70 in SIM and USIM case lt sw1 gt lt sw2 gt Integer character format Information from the SIM about the execution of the actual command These parameters are delivered to the TE in both cases on successful or failed execution of the command lt sw1 gt lt sw2 gt integer type containing the SIM information and can be 0x90 0x00 normal entry of the command Ox9F OxXX length XX of the response data 0x92 0x0X update successful but after using an internal retry routine
131. PAS Phone Activity Status This command displays the current activity status of the H3xx like call in progress or ringing Command Syntax Response Action Remarks Execute Read AT CPAS CPAS lt pas gt The Execute and Read OK commands return the activity status lt pas gt of the or H3xx They can be used to H3 Family AT Commands User Manual Page 81 of 375 FIDCCON CME ERROR lt err gt interrogate the H3xx Test AT CPAS CPAS list of supported lt pas gt s OK The following table shows the CPAS parameters lt Parameter gt Description lt pas gt 0 Ready The H3xx allows commands from the terminal 1 unavailable MT does not allow commands from TA TE 2 Unknown The H3xx is not guaranteed to respond to instructions 3 Ringing MT calls The H3xx is ready for commands from the terminal but the ringer is active 4 Call in progress The H3xx is ready for commands from the terminal but a call is in progress 5 asleep MT is unable to process commands from TA TE because it is in a low functionality state Example AT CPAS CPAS 0 OK AT CPAS CPAS 0 5 OK AT CPAS CPAS 4 OK AT CPAS Voice call active state CPAS 4 OK H3 Family AT Commands User Manual Page 82 of 375 FIDCCON 5 4 2 CLCC List Current Calls This command displays a list of all current H3xx calls and their statuses and also enables disables the unsolicited i
132. PDP_type gt the parameter lt h_comp gt s value ranges for each OK lt PDP_type gt are returned on a separate line The following table shows the CGDCONT parameters protocol type lt APN gt Access Point Name lt Parameter gt Description lt cid gt Numeric parameter specifying a particular PDP context definition PDP Context Identifier The parameter is local to the Terminal Mobile Terminal interface and is used in other PDP context related commands The value is from 1 to 10 lt PDP_type gt String parameter in quotation marks specifying the type of packet Packet data data protocol IP IP Internet Protocol IETF STD 5 IPV6 Internet Protocol version 6 IETF RFC 2460 String parameter in quotation marks which is a logical name that is used to select the GGSN or the external packet data network If the value is null or omitted the subscription value is requested lt PDP_address gt String parameter in quotation marks which identifies the ME in the address space applicable to the PDP If the value is null or omitted a value may be provided by the terminal during the PDP startup procedure or failing that a dynamic address is requested The Read form of the command continues to return the null string even if an address has been allocated during the PDP startup procedure The allocated address may be read using the CGPADDR command The default value is 0
133. PIP dns convert to ip fail 2003 TCPIP socket number limited 2004 TCPIP invalid operation 2005 TCPIP protol error 2006 TCPIP send data too long 2007 TCPIP send data memory failed 2008 TCPIP service not in correct state 2009 TCPIP pdp not defined 2010 TCPIP new socket failed 2011 TCPIP socket bind fail 2012 TCPIP socket connect fail 2013 TCPIP socket send fail 2014 TCPIP socket close fail 2015 TCPIP get socket receive buffer failed 2016 TCPIP receive data failed 2017 TCPIP socket used 2018 TCPIP get send buffer size failed 2019 TCPIP socket send data failed 2020 TCPIP socket send data size limited 2021 TCPIP socket set listening mode failed 2022 TCPIP socket listen fail 2023 TCPIP socket error 2024 TCPIP socket not opened 2025 TCPIP tcp stack confige failed 2026 TCPIP socket no data to send 2027 TCPIP socket send invalid data state 2028 TCPIP socket close client 2029 TCPIP ping error 2030 TCPIP ppp not connected H3 Family AT Commands User Manual Page 374 of 375 FIDCCON 2031 TCPIP mipcall not active 2032 TCPIP etcpip not active 2033 TCPIP not def4 H3 Family AT Commands User Manual Page 375 of 375
134. REGISTERS 25 22 scccscccs cece kialeveces etches cdccsevUesdetced eas becse dace REE a Ea G REEERE EAREN RSRS 30 ADO SQ sessiis tins cctnecstaaestaestaaesd cag tb dae E E E 32 BANE S12 csi E E Gutadhepucateocs dead ar edeteden bata veagantser en aniteabye deahecs 32 4 1 8 amp V View Contiguration c c iceceitiaastitedees clint ian a eis Adc eS 33 H3 Family AT Commands User Manual Page 5 of 375 FIDCCON 4 1 9 amp F Set to Factory Defined Configuration cccececeseesesceseseeseseeseneesesenseseeeeseeseseeseseeeeenseseees 34 4 1 10 Z Reset to Default Configuration ccccceccesecesesesseseseeseeeesesensceeceesecsesecaesesseneeseeeseeeseeeesseeesaes 35 Ml 11 amp W Store User Profile acssesories sste iii eiT SASN 36 41 12 amp Y Detault User Pr fil srsincorenisinni ieioea isst iiai iS iss 37 4 1 13 CRSM Restricted SIM ACCESS eceeceeeesecesseseceseseseeseeesesesesecseseseseseacaesesceecatecseeseecaeeeeeesearateees 38 4 1 14 GTUSIM Checks for USIM Card e ssssssssseesssisesssiserssrrrssrerrssresrsnresrsnrestssresrsnresrenresrenrenrenresrent 42 411S FAG ripene r E a s E E E e 43 42 Sleep Mode Command Surinoita e EEE ET dices EE EON OEN 44 4 2 1 S24 Set Number of Seconds Delay Before H3xx Enters Sleep Mode ccceseceseseeeeees 44 4 3 Error Handling COMMandS ccecccscsccssssesscsscsscsssseessssecsesscsseseesesecssssessesscesenscsscsscsecsessecsesseetesseesesteneeas 46 4 3 1 CMEE Report Mobile Equipme
135. SDU size gt lt SDU error ratio gt lt Residual bit error ratio gt lt Delivery of erroneous SDUs gt lt Transfer delay gt lt Traffic handling priority gt lt Source statistics descriptor gt lt Signalling indication gt lt CR gt lt LF gt CGEQMIN lt cid gt lt Traffic class gt lt Maximum bitrate UL gt lt Maximum bitrate DL gt lt Guaranteed bitrate UL gt lt Guaranteed bitrate DL gt lt Delivery order gt lt Maximum SDU size gt lt SDU error ratio gt lt Residual bit error ratio gt lt Delivery of erroneous SDUs gt lt Transfer delay gt lt Traffic handling priority gt lt Source statistics descriptor gt lt Signalling indication gt each defined context Test AT CGEQMIN CGEQMIN lt PDP_type gt list of supported lt Traffic class gt s list of supported lt Maximum bitrate UL gt s list of supported lt Maximum Test command returns values supported as a compound value If the MT supports several PDP types the parameter value H3 Family AT Commands User Manual Page 280 of 375 FIDCCON bitrate DL gt s list of supported lt Guaranteed bitrate UL gt s list of supported lt Guaranteed bitrate DL gt s list of supported lt Delivery order gt s list of supported lt Maximum SDU size gt s list of supported lt SDU error ratio gt s list of supported lt Residual bit error ratio gt s
136. SIM PIN is blocked the error code 11 or SIM PIN required is returned The user must then issue the Set command with the SIM PIN Read AT CPI CPIN lt code gt The Read command returns an N OK alphanumeric string indicating the status of the SIM card and whether a password is required or not This is an independent CME ERROR SIM card lock status check only and does lt err gt not check the phone lock status Test AT CPI N OK The following table shows the CPIN parameters lt Parameter gt Description lt puk gt PUK code for unblocking a blocked phone lt pin gt Current PIN for unlocking a locked phone lt newpin gt New PIN after changing or after entering PUK 4 8 digits lt code gt READY MT is not pending for any password SIM PIN MT is waiting SIM PIN to be given SIM PUK MT is waiting SIM PUK to be given PH SIM PIN MT is waiting phone to SIM card password to be given PH FSIM PIN MT is waiting phone to very first SIM card password to be given PH FSIM PUK MT is waiting phone to very first SIM card unblocking password to be given H3 Family AT Commands User Manual Page 165 of 375 Bs FIBOCOM SIM PIN2 SIM PUK2 PH NET PIN PH NET PUK PH NETSUB PIN PH NETSUB PUK PH SP PIN PH SP PUK PH CORP PIN PH CORP PUK MT is waiting SIM PIN2 to be given this lt code gt is recommended to be returned only when th e last executed command resulted i
137. ST 007 000 001 CRLP 061 061 048 006 CR 000 CRC 000 STORED PROFILE 1 amp C1 amp D2 amp K3 E1 QO V1 X0 S00 000 S02 043 S03 013 S04 010 S05 008 07 030 S12 020 CBST 007 000 001 CRLP 061 061 048 006 CR 000 CRC 000 OK 4 1 9 amp F Set to Factory Defined Configuration This command restores the factory default configuration profile The H3xx only supports one factory default profile O Note For H350 xxx 10 H380 Read command are not supported Command Syntax Response Action Remarks OK Set AT amp F lt value gt or CMS ERROR lt err gt lt current profile Read AT amp F number gt The Test command for amp F is not Ti defined by ITU and therefore is not es supported by the H3xx The H3xx returns an error The following table shows the amp F parameters lt Parameter gt Description lt value gt 0 Factory default configuration profile This is the only value supported Example AT amp F amp F 0 OK H3 Family AT Commands User Manual Page 34 of 375 FIDCCON 4 1 10 Z Reset to Default Configuration This command drops the current call and resets the values to default configuration Command Syntax Response Action Remarks Set ATZ lt val OK ee or CMS ERROR lt err gt Read ERROR The Read command for Z is not defined and therefore is not supported by the H3xx The H3xx returns an error Test ERR
138. Supplementary Service Data ccc ccccccccsccsesecsseseesesscesesscsecseeseeseens 99 5 6 3 COLP Connected Line Identification Presentation eee eee eseeseseseecseneeeseseseseneeeaes 105 6 Phone Book and ClOCK eeeceeececeseseecsseeesesesesesessesesesceeacsesesceesacscsesecseacsesesacacaesesseecacecseseecaceceeeseaeaeeeeeneeaeeeeeeanees 107 6 1 Directory Access Commands Phone Book cccccccccsescesesscesesscssesecsesscesesecsecsecsecsecsecseesseecssceesseesseas 107 6 1 1 CPBS Select Phone Book M MOSY ccccccsscccssescsscssesecseesecsesscesesecssesecssescesesecescsececsecsecsteaes 107 6 1 2 CPBR Read Phone Book EntrieS ceeecescsesseseseseeeeeeseseeesesecseneseenecaceeseeeeecaeeeeeeeearaeeeeetees 109 6 1 3 CPBF Find Phone Book Beri trne sa es cacti ocacoudnnanta cesdabapectdea tendons vtatinavncuestocatwussnetiateastaaderiereeaeaias 112 6 1 4 CPBW Write Phone Book Entry cc cc ccccccsccscescescsscsscsecsecseesecssesecscsscecsscsecsecsesseeseeccasseesaeas 114 6 1 5 CSVM Set Voice Mail SOrver uo ee eeesceeeseseeeseeseeeseseseeceeesesesesecseseseseeeeseeeeeeseecaceceeeeeecaeeeeeeees 116 6 2 System Date and Time ACCESS COMMANGS ccccccscsscssesseseeseeseecsesecssescesseacesesecsacsecsecseesececseeeeesaeaes 118 6 2 1 CCLK Read Set System Date and Time ccc cccccccsccseesceseesceseecssesecseesecsesecescsecsscsecsecstens 118 POMS Ren nee ee a RDC Dt OA nea oe N GT E nO MIP ONES RA SPOT OTE T eNO
139. T GMI OK AT FMI FMI lt manufacturer_ID gt AT FMI OK Example AT CGMI CGMI Fibocom OK 3 2 CGMM GMM FMM Request Model ID These commands request the model identification The H3xx outputs a string containing information about the specific model including a list of the supported technology used and the particular model number Command Response Action AT CGMM CGMM lt list of supported technologies gt lt model gt AT CGMM OK AT GMM GMM lt list of supported technologies gt lt model gt FIDCCON AT GMM OK AT FMM FMM lt list of supported technologies gt lt model gt AT FMM OK Example AT CGMM CGMM WCDMA Quad Band H330S CGMM GSM1800 GSM900 GSM1900 GSM850 WCDMA2100 WCDMA900 WCDMA190 0 WCDMA850 MODEL H3308S OK 3 3 CGMR GMR FMR Request Revision These commands request the revision identification The H3xx outputs a string containing the revision identification information of the software version contained within the device Command Response Action AT CGMR CGMR lt revision gt AT CGMR OK AT GMR GMR lt revision gt AT GMR OK AT FMR FMR lt revision gt AT FMR OK Example AT CGMR CGMR H330S_V1H 00 08 OK H3 Family AT Commands User Manual Page 19 of 375 FIDCCON 3 4 CGSN GSN Request Product Serial Number Identification This command displays the product se
140. T MIPSEND 2 10 gt 0123456789abc OK MIPPUSH 2 0 MIPSEND 2 0 2048 OK 0123456789 lt CR gt lt LF gt Only data without any information AT GTSET IPRFMT 2 0 OK AT MIPSEND 2 10 gt 0123456789abc OK MIPPUSH 2 0 MIPSEND 2 0 2048 OK lt CR gt lt LF gt MIPRTCP 2 10 0123456789 lt CR gt lt LF gt H3 Family AT Commands User Manual Page 323 of 375 FiIDCCON 13 8 MIPPUSH Push Data into Protocol Stack This command causes the H3xx to push the data accumulated in its accumulating buffers into the protocol stack It is assumed that before using this command some data should exist due to previous MIPSEND commands The destination IP and destination port can be used only for UDP listen mode Command Syntax Response Action Remarks Set MIPPUS MIPPUSH Optional parameters are used only for UDP H lt Sock lt Socket_ID gt lt Status connections If the Destination IP and et_ID gt lt gt lt accumulated_sen Destination Port are not provided by the user Destinatio t_length gt a datagram is sent to the last target or the n_IP gt lt OK default target provided by the MIPOPEN Destinatio command or oe lt accumulated_sent_length gt this parameter ERROR counts how many bytes were sent to the remote side by the H3xx TCP IP stack When user open socket lt accumulated_sent_length gt initialized to zero Size of lt accumulated_sent_length gt is four oc
141. T2 use for AT command When UART2 use for AT command it supports all AT commands except AT CMUX Note UART2 can not support HW flow control No CTS RTS DTR DSR DCD RI pin The MUX feature can not support in UART2 10 3 2 UARTSEND Send data to UART2 When UART2 use for send receive data Please use AT GTSET UARTREV lt mode gt at the port which you want data receive The following table shows the UARTREV parameters lt Parameter gt Description lt mode gt 0 When receive data only report data length default 1 When receive data report all data by UARTREV This command intends to send data to UART2 This command can be used in UART1 or USB ports to send data to UART2 The data format is in hex As the input command can only be character so here use two characters to indicate one hex number Eg 35 means 0x35 Module will change the format internally Note For H350 xxx 10 H380 this commands is not supported H3 Family AT Commands User Manual Page 227 of 375 FIDCCON Command Syntax Response Action Remarks Set AT UARTSEND OK Used to send data to lt source gt lt data gt Or UART2 CME ERROR lt err gt Test AT UARTSEND UuARTSEND lt source gt lt data gt Return supported values i OK or ERROR The following table shows the GPIO parameters lt Parameter gt Description lt source gt 3 For inter
142. User Manual Page 174 of 375 FIDCCON 9 Network 9 1 Network Commands 9 1 1 CSQ Signal Strength This command displays the received signal strength indication lt rssi gt and channel bit error rate lt ber gt from the H3xx Command Syntax Response Action Execute Read AT CSQ CSQ lt rssi gt lt ber gt AT CSQ OK Test AT CSQ CSQ list of supported lt rssi gt s list of supported lt ber gt s OK The following table shows the CSQ parameters lt Parameter gt Description lt rssi gt 0 through 31 covers the range of 113 dbm or less to 51 dbm or greater 0 113 dBm or less 1 111 dBm 2 30 109 53 dBm 31 51 dBm or greater 99 not known or not detectable lt ber gt Channel bit error rate in percent 0 7 RXQUAL values in the TS 45 008 table 99 Unknown or not detectable Example FIDCCON AT CSQ CSQ 23 99 OK AT CSQ CSQ 0 31 99 0 7 99 OK 9 1 2 CRLP Radio Link Protocol This command displays the Radio Link Protocol parameters that are used when non transparent data calls are originated Command Syntax Response Action Remarks oc ee ee The Set command Apt or enables you to change 1 gt lt N2 gt CME ERROR lt err gt the RLP parameters Read CRLP CRLP lt iws gt lt mws gt lt T1 gt lt N2 gt OK Test CRLP CRLP list of supported lt iws gt s list of supported lt mws gt
143. VOICE DATA call after a RING CRING indication is sent to the terminal If the incoming call is answered CSD connected the H3xx sends a CONNECT notification to the terminal If the MT call fails the possible notifications are H3 Family AT Commands User Manual Page 56 of 375 FIDCCON NO CARRIER Connection Failure ERROR General Failure Note A waiting call an incoming call while a call is in progress is announced by CCWA rather than RING A waiting call can be answered only if it is a voice call The waiting voice call should be answered using the ATA command which will put the active call on hold and will connect the waiting call making it the active call This ATA action is the same action as AT CHLD 2 Example Example Answering a voice call AT CRC 1 CRING VOICE CRING VOICE ata OK VOICE call connected H3xx is in Command mode ath OK NO CARRIER Example Answering a data call CRING REL ASYNC CRING REL ASYNC ata Connecting dots are not displayed OK IDATA call connected H3xx is in Online Data mode Note In a CSD call call release is not valid during the phase of call negotiation from OK until connect Call 5 3 6 CRC Cellular Result Codes and RING CRING Incoming Call Indication This command controls whether or not to present the extended format of an incoming call indication The RING CRING indication is sent from the H3xx to the terminal when the H3xx is al
144. X times 0x92 0x40 memory problem 0x94 0x00 no EF selected 0x94 0x02 out of range invalid address 0x94 0x04 file ID not found pattern not found 0x94 0x08 file is inconsistent with the command 0x98 0x02 no CHV initialized 0x98 0x04 access cond Not fullfiled unsucc CHV verify authent failed 0x98 0x08 in contradiction with CHV status 0x98 0x10 in contradiction with invalidation status 0x98 0x40 unsucc CHV verif Or UNBLOCK CHF CHV blocked UNBL blocked 0x98 0x50 increases can not be performed Max value reached 0x61 OxXX SW2 indicates the number of response bytes still available Use GET RESPONSE to access this data 0x62 OxXX Warning state unchanged 0x62 0x00 Warning no information provided 0x62 0x81 Warning part of returned data may be corrupt 0x62 0x82 Warning end of file record reached bad cmd H3 Family AT Commands User Manual Page 40 of 375 FIDCCON 0x62 0x83 Warning selected file invalidated 0x62 0x84 Warning bad file control information format 0x63 OxXX Warning state unchanged 0x63 0x00 Warning no information provided 0x63 0x81 Warning file filled up with last write 0x63 0xCx Warning counter value is x 0x64 OxXX Error state unchanged 0x65 OxXX Error state changed 0x65 0x00 Error no information provided 0x65 0x81 Error memory failure 66 xx Security Error Ox66 OxXX Security Error 0x67 OxXX incorrect parameter P3 0x68 OxXX Check Error CLA function not
145. acturer specific volume range 0 is lowest volume not mute The default value is 4 11 2 2 CLVL Loudspeaker Volume This command sets the volume of the internal loudspeaker of the H3xx Note In this command the new value remains after power cycle The CLVL command can be used even when the SIM is not inserted Command Syntax Response Action Remarks Set CLVL lt level gt OK The Set command sets the internal r loudspeaker volume level CME ERROR lt err gt Read CLVL CLVL lt level gt The Read command displays the OK current internal loudspeaker volume setting Test CLVL CLVL list of The Test command displays the supported lt level gt s possible loudspeaker volume settings OK The following table shows the CLVL parameters lt Parameter gt Description lt level gt 0 7 Manufacturer specific volume range 0 is lowest volume not mute The default value is 4 11 2 3 CMUT Mute Unmute Microphone and Speaker Path This command is used to mute unmute the currently active Microphone and Speaker path by overriding the current mute state The CMUT setting should take effect only for the current call or for the next call once the command setting was typed in idle mode H3 Family AT Commands User Manual Page 239 of 375 FIDCCON Command Syntax Response Action Remarks Set CMUT lt state gt OK The Set command oe enab
146. affect the issuing of the unsolicited result code RING or CRING Command Syntax Response Action Remarks Set AT CGAUTO OK The set command disables or enables lt n gt Or an automatic positive or negative response auto answer to the receipt of CME ERROR lt error gt N a NW initiated Request PDP Context Activation message from the network Read AT CGAUTO CGAUTO lt n gt The read command returns the current OK setting for the auto answer whether it s enabled or disabled Test AT CGAUTO CGAUTO list of The test command returns the values of supported lt n gt s lt n gt supported by MT as a compound OK value The following table shows the CGAUTO parameters lt Parameter gt Description lt n gt Is a numeric parameter which indicates the setting for the auto answer to be used 0 Turn off automatic response for Packet Domain only Packet Domains network requests are manually accepted or rejected by the CGANS command 1 Turn on automatic response for Packet Domain only H3 Family AT Commands User Manual Page 277 of 375 FIDCCON Packet Domain network requests are automatically accepted according to the description above 2 Modem compatibility mode Packet Domain only Automatic acceptance of Packet Domain network requests is controlled by the SO command Manual control uses the A and H commands respectively to accept and reject Packet D
147. ailable attempts is provider dependant Typically it is 3 attempts for PIN 10 attempts for PUK This command will return error if SIM is not inserted Note For H350 xxx 10 H380 this command is not supported Command Syntax Response Action Remarks Read AT TPI TPIN lt chv1 gt N lt unb1_chv1 gt lt chv2 gt lt unb1_chv2 gt or CME ERROR lt err gt The following table shows the TPIN parameters lt Parameter gt Description lt chv1 gt Number of remaining PIN attempts lt chv2 gt Number of remaining PIN2 attempts lt unbl_chv1 gt Number of remaining PUK attempts lt unbl_chv2 gt Number of remaining PUK2 attempts Example AT TPIN H3 Family AT Commands User Manual Page 168 of 375 Bs FIBOCOM TPIN 3 10 3 10 OK AT CPIN 7777 CME ERROR incorrect password AT TPIN TPIN 2 10 3 10 OK 8 1 5 CPWD Change Password This command sets a new password for the facility lock The password can only be changed once the required facility is enabled by the CLCK command A password can be changed only if the provided password lt oldpwd gt has been verified The entered password lt newpwd gt must also comply to the password rules The facility value lt fac gt is not case sensitive In the password value letters are not allowed Command Syntax Response Action Remarks Set AT CPWD lt fa_ OK cep olupwdas or Set a new
148. al that it is ready to receive the data Likewise if the H3xx is unable to receive data it places the CTS line in an inactive condition Command Syntax Response Action Set AT amp K lt param gt OK or CME ERROR lt err gt Read AT amp K amp K lt param gt OK Test AT amp K amp K list of supported lt param gt s OK The following table shows the amp K parameters lt Parameter gt Description lt param gt 0 Disable all terminal H3xx flow control 3 Enable CTS RTS terminal H3xx flow control The default value is 0 H3 Family AT Commands User Manual Page 207 of 375 10 1 4 IFC RTS CTS Flow Control This parameter controls the operation of the local flow control between the terminal and H3xx during the data state when V 42 error control is used or when fallback to non error control mode is specified to include buffering and flow control It accepts two numeric subparameters e lt DCE_by_DTE gt Specifies the method to be used by the terminal to control the flow of received data from H3xx e lt DTE_by_DCE gt Specifies the method to be used by the H3xx to control the flow of transmitted data from the terminal Command Syntax Response Action OK AT IFC lt DCE_by_DTE Set or gt DTE_by_DCE ERROR IFC lt rate gt OK IFC list of supported lt DCE_by_DTE gt s list of Test AT IFC supported lt DTE_by_DCE gt s OK The follo
149. alue Note For H350 xxx 10 H380 this commands is not supported Command Syntax Response Action Remarks Set AT MCl lt OK This command will return OK Execute Filter gt lt en an only The neighbor cell information able_TA gt will return back with MCl format CME ERROR lt err gt few senconds later or AT MCI Read AT MCI MCI lt Filter gt The Read command returns the lt enable_TA gt current set lt Filter gt and OK lt enable_TA gt values Test AT MCI MCI List of The Test command returns the supported lt Filter gt s ranges of lt Filter gt s supported Range of supported values and lt enable TA gt s lt enable TA gt supported values OK H3 Family AT Commands User Manual Page 198 of 375 FIDCCON The following table shows the MCI parameters lt Parameter gt Description lt Filter gt The requested GSM band s ARFCNs This is an integer which can be a combination of all 1 15 1 GSM 850 2 GSM 900 4 GSM 1800 8 GSM 1900 The default value is 15 lt enable TA gt This parameter defines whether lt TA gt will be reported by MCI command Defined values 0 Do not report lt TA gt value 1 Report lt TA gt value The default value is 0 MCI Indication After AT MCI command the neighbor cell information will return back by this MCI indication format few senconds later MCI lt serving cell ARFCN gt lt
150. alue is 004 11 2 5 96 Echo Cancelling This command suppresses a large amount of the output sound picked up by the input device cancels all echo Command Syntax Response Action Remarks Set ATS96 lt n gt OK The Set command sets the echo cancelling r status CME ERROR lt err gt Read ATS96 lt n gt The Read command returns the echo OK cancelling status The following table shows the S96 parameters lt Parameter gt Description H3 Family AT Commands User Manual Page 241 of 375 FIDCCON lt n gt 0 7 echo cancelling range 0 is lowest echo cancelling not mute The default value is 0 11 2 6 CALM Alert Sound Mode This command handles the selection of the H3xx s alert sound mode The value of the command is saved after a power cycle Note For H350 xxx 10 H380 this commands is not supported Command Syntax Response Action Remarks Set CALM lt callmode gt OK The Set command sets the alert lt smsmode gt bn sound mode CME ERROR lt err gt Read CALM CALM lt mode gt The Read command displays the OK current alert sound mode setting Test CALM CALM list of The Test command displays the list supported of supported modes lt callmode gt lt smsmode gt s OK The following table shows the CALM parameters lt Parameter gt Description lt callmode gt Alert sound mod
151. ameter gt Description 129 Use for local call 128 Unknown lt index gt Index for a given phone book entry lt number gt Phone number of a given entry lt type gt The address type of a phone number 145 Use for international access code Note 128 is used to represent an email address or a mailing list In this case lt ph_type gt can be used to further differentiate between the two command CSCS lt text gt Text identifier for a phone book entry according to the character set as specified by lt nlength gt The maximum size of a phone number in digits There is a limited number of PB records that can be stored with this length The number of long PB records depends on the size of the SIM card EXT1 extension file If the extension file is full an attempt to store a new record with more than 20 digits returns an error lt tlength gt The maximum number of characters in the lt text gt entry This applies to GSM standard characters only Non GSM standard character sets and extended GSM H3 Family AT Commands User Manual Page 115 of 375 FIDCCON characters require additional space in storage In some cases when using such characters the text cannot be stored In this case the H3xx returns a text string too long error lt hidden gt indicates if the entry is hidden or not only available if a UICC with an active USIM applicat
152. amily AT Commands User Manual Page 61 of 375 FIDCCON code character 129 Default when making a local call 128 Type of number is unknown usually the output when the number itself is unknown lt subaddr gt NULL field not used String type subaddress of format specified by lt satype gt lt satype gt Field not used Value is always 128 unknown type of sub address octet in integer format lt alpha gt Name of the calling party if provided by the network lt CLI validity gt The Validity of the Calling Line Identity presentation O0 CLI valid 1 CLI has been withheld by the originator 2 CLI is not available due to networking problems or limitations of the originating network Example AT CLIP CLIP 0 1 CLI presentation is disabled by the H3xx 0 and is enabled by the network 1 OK AT CLIP 1 OK Example CLIP indication incoming call RING CLIP 13510503472 129 0 Example CLIP indication with restricted CLI AT CRC 1 OK H3 Family AT Commands User Manual Page 62 of 375 FIDCCON incoming call caller restricted the CLI presentation used AT CLIR CRING VOICE CLIP 128 128 1 5 3 9 CCWA Call Waiting Command This command controls the Call Waiting supplementary service including the settings and the queries of the H3xx and the network When the Call Waiting indication is enabled by the H3xx and there i
153. an is ket_ID gt lt Size gt lt Ti r defined in H3 Family AT Commands User Manual Page 316 of 375 FIDCCON me span gt ERROR milliseconds MIPDSETS lt err gt Read MIPDSETS MIPDSETS lt Socket_ID gt lt Current Size Settings gt lt Time span gt OK For all ACTIVE sockets Test MIPDSETS MIPDSETS 1 4 list of supported lt size gt s list of supported lt Timespan gt s OK The following table shows the MIPDSETS parameters lt Parameter gt Description Size Size of the buffer 128 lt size lt 2048 The default value is 2048 Time span 0 1000 The default value is 0 Example AT MIPDSETS 1 512 OK AT MIPDSETS MIPDSETS 1 4 128 2048 0 1000 OK H3 Family AT Commands User Manual Page 317 of 375 FiIDCCON 13 6 MIPSEND Send Data 13 6 1 Send Data at normal mode This command causes the H3xx to store the data that the terminal provides in the accumulating buffer and then send this data using protocol stack when the amount of data reaches the predefined amount see MIPSETS Set Size and Timeout for Automatic Push on Before sending data a valid connection must be created using the MIPCALL and MIPOPEN commands Recommends that the terminal sets the watermark in the accumulating buffer prior to this command using the MIPSETS command By default the watermark is set to 2048 byte
154. ands User Manual Page 156 of 375 FIDCCON 1 Deletes all read messages 2 Deletes all read messages and sent MO messages 3 Deletes all read messages sent and unsent MO messages 4 Deletes all messages Example AT CMGD 4 OK AT CMGD 1 3 OK 7 1 19 CGSMS Select Service for MO SMS Messages This command handles the selection of the service or service preference used by the H3xx to send mobile originated SMS messages Note The Set command selects the service or service preference used to send SMS messages The value that is set is retained after a power cycle Command Syntax Response Action Remarks Set CGSM OK The Set command selects the service or S lt serv CME ERROR service preference used to send SMS ice gt Sens messages The value that is set is retained after a power cycle Read CGSM CGSMS a A sservice gt The Read command displays the OK current SMS service preference setting Test CGSM CGSMS list of The Test command displays a list of S 7 currently available currently available lt service gt s on the network lt service gt s OK H3 Family AT Commands User Manual Page 157 of 375 FIDCCON The following table shows the CGSMS parameters lt Parameter gt Description lt service gt Indicates the service or service preference to be used 0 GPRS 1 Circuit switched default 2 GPRS preferred use circuit switched if GPRS i
155. arameters lt Parameter gt Description lt L2P gt a string parameter that indicates the layer 2 protocol to be used between the TE and MT NULL none for PDP type OSP IHOSS Obsolete PPP Point to point protocol for a PDP such as IP PAD character stream for X 25 character triple X PAD mode Obsolete X25 X 25 L2 LAPB for X 25 packet mode Obsolete M OPT PPP MS supports manufacturing specific protocol M HEX MS supports manufacturing specific protocol M RAW_IP MS supports manufacturing specific protocol lt cid gt Anumeric parameter which specifies a particular PDP context definition see the CGDCONT and CGDSCONT commands Note After data transfer is complete the MT re enters the command state and the final result code is displayed on TE In error case the final result code NO CARRIER or CME ERROR lt error gt is displayed PS attachment and PDP context activation procedures may take place prior to or during the PDP startup if they have not already been performed using the CGATT and CGACT commands If no lt cid gt is given or if there is no matching context definition the MT shall attempt to activate the context with whatever information is available to the MT The other context parameters shall be set to their default values If the activation is successful data transfer may proceed After data transfer is complete and the layer 2 protocol termination procedure has completed successfully
156. ase sensitive text substring to search for according to the character set specified by the CSCS command lt index1 gt Index for a given phone book entry H3 Family AT Commands User Manual Page 112 of 375 FIDCCON lt index2 gt lt number gt Phone number of a given entry lt type gt The address type of a phone number 129 Use for local call 145 Use for international access code 128 Unknown Note 128 is used to represent an email address or a mailing list In this case lt ph_type gt can be used to further differentiate between the two lt text gt Text identifier for a phone book entry that starts with the substring lt findtext gt according to the character set as specified by command CSCS lt hidden gt indicates if the entry is hidden or not only available if a UICC with an active USIM application is present 0 phonebook entry not hidden 1 phonebook entry hidden lt group gt string type field of maximum length lt glength gt character set as specified by command Select TE Character Set CSCS lt adnumbe gt string type phone number of format lt adtype gt lt adtype gt type of address octet in integer format refer TS 24 008 subclause 10 5 4 7 lt secondtext gt string type field of maximum length lt slength gt character set as specified by command Select TE Character Set CSCS lt email gt string type field of maximum length lt elength gt cha
157. aximum bitrate UL gt s list of supported lt Maximum bitrate DL gt s list of supported lt Guaranteed bitrate UL gt s list of supported lt Guaranteed bitrate DL gt s list of supported lt Delivery order gt s list of supported lt Maximum SDU size gt s list of supported lt SDU error ratio gt s list of supported lt Residual bit error ratio gt s list of supported lt Delivery H3 Family AT Commands User Manual Page 287 of 375 FIDCCON of erroneous SDUs gt s list of supported lt Transfer delay gt s list of supported lt Traffic handling priority gt s list of supported lt Source statistics descriptor gt s list of supported lt Signalling indication gt s The following table shows the CGEQREQ parameters lt Parameter gt Description lt cid gt A numeric parameter which specifies a particular PDP context definition see CGDCONT and CGDSCONT commands lt Traffic class gt A numeric parameter that indicates the type of application for which the UMTS bearer service is onfirmat 0 conversational 1 streaming 2 interactive 3 background subscribed value If the Traffic class is specified as conversational or streaming then the Guaranteed and Maximum bitrate parameters should also be provided Other values are reserved lt Maximum bitrate UL gt A numeric parameter that indicates the maximum number of kbits s
158. bet GSM 03 38 subclause 6 2 1 UCS2 2 byte Universal Character Set Unicode ISO IEC 10646 32 HEX Charater strings consist only of hexadecimal numbers from 00 to FF Example AT CSCS CSCS UCS2 IRA HEX GSM OK AT CSCS CSCS IRA OK AT CPBS SM OK AT CPBW 1 8475763000 129 Lin Zhao OK AT CSCS UCS2 OK AT CPBR 1 CPBR 1 8475763000 129 004C0069006E0020005A00680061006F OK H3 Family AT Commands User Manual Page 21 of 375 FIDCCON 3 6 CIMI Request IMSI This command displays the International Mobile Subscriber Identity number Command Response Action AT CIMI CIMI lt imsi gt AT CIMI OK or CME ERROR lt err gt Example AT CIMI CIMI 314566320021400 OK 3 7 CFSN Read Factory Serial Number This command is used to query the factory serial number Command Response Action AT CFSN AT CFSN CFSN lt fsn gt OK Example AT CFSN CFSN 1234567890 OK H3 Family AT Commands User Manual Page 22 of 375 FIDCCON 3 8 I Request Identification Information This command displays various H3xx information items Command Response Action ATIn lt information item n gt or CME ERROR lt err gt The following table shows the information items that are supported by the H3xx ATIn Description Output Just Demo Remark ATI Same a
159. c parameter that specifies the mean throughput class Example AT CGQREQ CGQREQ IP 0 3 0 4 0 5 0 9 1 18 31 OK AT CGQREQ CGQREQ 1 2 4 3 9 10 CGQREQ 2 2 4 3 9 10 OK AT CGQREQ 1 0 0 0 10 OK AT CGQREQ CGQRE Q 1 0 4 0 0 10 CGQREQ 2 2 4 3 9 10 OK H3 Family AT Commands User Manual Page 268 of 375 FIDCCON 12 2 5 CGATT GPRS Attach or Detach This command attaches detaches the ME to from the GPRS service When the command has completed the ME remains in V 25ter command state If the ME is already in the requested state the command is ignored and the OK response is returned If the requested state cannot be achieved an ERROR or CME ERROR response is returned Extended error responses are enabled by the CMEE command Any active PDP contexts will be automatically deactivated when the attachment state changes to detached Command Syntax Response Action Remarks Set AT CGATT OK The Set command attaches detaches the ME to from lt state gt or the GPRS service CME ERROR lt err gt Read AT CGATT CGATT lt state gt The Read command returns the OK current GPRS service state Test AT CGATT CGATT list of The Test command requests supported lt state gt s information on the supported GPRS OK service states Note This command has the characteristics of both the V 25ter action and parameter commands Therefore it has the Read form in addi
160. called_addres s gt String that identifies the called party in the address space applicable to the PDP For communications software that does not support arbitrary characters in the dial string a numeric equivalent may be used Also the comma character may be used as a substitute for the period character For PDP type OSP IHOSS the following syntax may be used for lt called_address gt lt host gt lt port gt lt protocol gt where lt host gt lt port gt and lt protocol gt are defined in CGDCONT Define PDP Context For communications software that does not support arbitrary characters in the dial string a numeric value equivalent to the hostname may be used However this should be avoided if at all possible lt L2P gt String variable which indicates the layer 2 protocol to be used For communications software that does not support arbitrary characters in the dial string the following numeric equivalents are used 0 NULL 1 PPP H3 Family AT Commands User Manual Page 271 of 375 FIDCCON 2 PAD 3 X25 9 yyyy M xxxx Other values are reserved and result in an ERROR response to the Set command Note V 250 and certain communications software do not permit arbitrary characters in the dial string The lt L2P gt and lt called_address gt strings are therefore specified as containing digits 0 9 only lt cid gt Digit string which specifies a par
161. ceseaeeeseeseesaeeateaes 354 14 12 FTPLIST Request List ccc csccsccsesscssesecssesecsseseesesscsscsecsacsecsecseesecsesesecsscsecsecnsesscseseeeseseeeees 355 14 13 FTPSTAT Request Status cccccsscssesscssssecsessccsesscssesecsseseesssscesesscesesecsscssssecsesseseeesenseseenees 357 14 14 FTPSYST Request Operating System Type ccccccesssescssesesesseseeseseneeenecseeecseeessesenseeeeseeeeaeeees 358 14 15 FTPNOOP INO Operation seisnes roinnean rasai Ee aa Eaa aa Ea aE E EE 359 14 16 FTPSTOR Store File on Remoter Server ssssssesesiesesessessesessessesesessesesresrsresresessesesresesessesesresees 360 14 17 FTPRETR Retrieve a File ccceceeeeccsceseesceseeseeceescsecscenecaeceesaesecaeseceessesaecaesaesaeeeeeatereneeaeeneats 361 14 18 FTPGET Enter the File Download Mode eceeecesesesseseseseseseeeeeeseseneseeseseneeeeeeseeeaescnevaceeseeaeeeaees 363 14 19 FTPRECV Read Data through the Port ccc ccccccsscscsscsecsscsecsecseesecscsscsecsecsecsecseeseeseseceseseesaeas 365 15 Error COM G5 2cc Seca ps test sceacoassd os OEE AR E eee sth eel ww enecodessie eave ees 367 1S1 CME EMO sirae ee recepertr tee ceereretererrentretrcarerrecerseetrarecreere rete nrrectere enters reterer ENS 367 19 2 CMS EMOL ccd cnass scecdtendes i ies tens icdiveds Rasns aacdarietee E 370 159 MC PAE OM cesses coe ce cases bcctecsasesecedoes tet aaaea E EE A AAE ARa eters ER 374 H3 Family AT Commands User Manual Page 12 of 375 FiDCCON 1 Preface 1 1
162. command please send AT GTSET LPMMODE 1 And for H350 xxx 10 H380 this command is not supported Command Syntax Response Action Remarks Set ATS24 lt value OK The Set command sets the amount gt of time in seconds the H3XX should wait before entering Sleep mode Read ATS24 lt value gt The Read command returns the OK current value The following table shows the S24 parameters lt Parameter gt Description lt value gt Number of seconds 0 lt n lt 255 H3 Family AT Commands User Manual Page 44 of 375 FIDCCON 0 Disable Sleep mode gt 0 Enable Sleep mode The default value is 000 Note H3xx can not enter sleep mode in 30 seconds at the beginning of power up Example ATS24 000 OK ATS24 5 OK ATS24 005 OK If there are no Radio activities Radio and Data transmission on UART the H330S will enter sleep mode in 5 seconds H3 Family AT Commands User Manual Page 45 of 375 FIDCCON 4 3 Error Handling Commands 4 3 1 CMEE Report Mobile Equipment Error The Set command disables or enables the use of result code CME ERROR lt err gt as an indication of an error relating to the functionality of the H3XX When enabled H3xx related errors cause a CME ERROR lt err gt final result code instead of the regular ERROR final result code Usually ERROR is returned when the error is related to syntax invalid parameters or terminal
163. ction Set AT CCID CCID lt ID gt OK or CME ERROR lt err gt Read AT CCID Same as above Test AT CCID OK Example AT CCID CCID 89860018190839008096 OK AT CCID OK AT CCID CCID 89860018190839008096 OK H3 Family AT Commands User Manual Page 43 of 375 FIDCCON 4 2 Sleep Mode Commands When the H3xx is connected using UART connection to external device a sleep mechanism is available In order to improve the power consumption the H3xx supports a low power consumption mode called Sleep mode The H3xx has internal decision conditions for entering and exiting sleep mode As the terminal and the H3xx operate in a combined system and as the communication between the H3xx and the terminal must be reliable there should be a mechanism agreed upon by both the H3xx and the terminal to coordinate their separate sleep mode entering and exiting sequences The H3xx will not enter sleep mode unless the terminal enables the H3xx by AT commands The following are the Sleep mode AT commands ATS24 Activates deactivates Sleep mode The H3xx receives a request to activate or deactivate Sleep mode 4 2 1 24 Set Number of Seconds Delay Before H3xx Enters Sleep Mode This command activates disables the Sleep mode The terminal sends ATS24 5 and if there are no radio and UART activities the H3xx enters sleep mode in 5 seconds Note For H350 xxx 00 this command doesn t take effect by default If you want to use this
164. d H3 Family AT Commands User Manual Page 297 of 375 FIDCCON lt d_comp gt s list of supported lt h_comp gt s OK The following table shows the CGDSCONT parameters lt Parameter gt Description lt cid gt PDP Context identifier It is a numeric parameter which specifies a particular PDP context definition The parameter is local to the TE MT interface and is used in other PDP context related commands The range of the permitted values is 1 10 lt p_cid gt Primary PDP context identifier It is a numeric parameter which specifies a particular PDP context definition which has been specified by use of the CGDCONT command The parameter is local to the TE MT interface The list of permitted values is returned by the test form of the command lt d_comp gt A numeric parameter that controls PDP data compression applicable for SNDCP only O off default if value is omitted 1 on manufacturer preferred compression 2 V A2 bis Other values are reserved lt h_comp gt A numeric parameter that controls PDP header compression O off default if value is omitted 1 on manufacturer preferred compression 2 RFC1144 applicable for SNDCP only 3 RFC2507 4 RFC3095 applicable for PDCP only Other values are reserved H3 Family AT Commands User Manual Page 298 of 375 FIDCCON Example AT CGDSCONT CGDSCONT 2 1 0 0
165. d The QoS profile consists of a number of parameters each of which may be set to a separate value A special form of the Set command CGQREQ lt cid gt causes the requested profile for context number lt cid gt to become undefined Read AT CGQREQ CGQREQ The Read command returns the current lt cid gt lt precedence gt settings for each defined context lt delay gt lt reliability gt lt peak gt lt mean gt OK Test AT CGQREQ _ CGQREQ The Test command returns values SPOP YPES pi supported as a compound value If the ME supponeg precegen supports several PDP types the cers stol parameter value ranges for each PDP Sp poren sdelay s type are returned on a separate line list of supported H3 Family AT Commands User Manual Page 267 of 375 FIDCCON lt reliability gt s list of supported lt peak gt s list of supported lt mean gt s OK The following table shows the CGQREQ parameters lt Parameter gt Description lt cid gt A numeric parameter that specifies a particular PDP context definition The value is from 1 to 10 lt precedence gt A numeric parameter that specifies the precedence class lt delay gt A numeric parameter that specifies the delay class lt reliability gt A numeric parameter that specifies the reliability class lt peak gt A numeric parameter that specifies the peak throughput class lt mean gt A numeri
166. da gt will be 145 otherwise 129 lt length gt Size of message in PDU mode format in octets excluding SMSC data lt mr gt Sent message reference number PDU Message header and contents in PDU mode format See description in CMGW Write Message to Memory Example AT CMGS 064593042 129 gt This is the message body lt CTRL Z gt lt CTRL Z gt ends the prompt text mode and returns to regular AT command mode OK AT CMGF 0 OK AT CMGS 24 gt 079179521201009511FF0B917962543940F 200080014004 10042004300440045 lt CTRL Z gt CMGS 128 OK H3 Family AT Commands User Manual Page 159 of 375 FIDCCON Note Any character sent by TE to H3xx before H3xx has reported a result of AT CMGS operation will abort AT CMGS command execution However if SMS was already sent to network and sending operation was successful the result of operation CMGS lt mr gt will be reported by H3xx If after aborting ATtCMGS command execution and before result of operation was reported by H3xx a second AT CMGS command is executed then the result of the second AT CMGS operation only will be reported by H3xx If AT CSCS HEX the SMS cannot be sent CMGS 7 1 21 CSCB Cell Broadcast Messages This command handles the selection of cell broadcast message types and data coding schemes received by the H3xx Command Syntax Response Action Remarks Set CSCB If mode 0 and lt mids gt is not The Set command sets lt mod
167. ded the ME automatically sets up a virtual call to the specified address after the PDP context has been activated If lt L2P gt and lt cid gt are supported the CGDCONT CGQREQ and other such commands may then be used in the modem initialization AT command string to set values for PDP type APN QoS and so on If lt L2P gt is not supported or is supported but omitted the ME uses a layer 2 protocol appropriate to the PDP type If lt cid gt is not supported or is supported but omitted the ME attempts to activate the context using one of the following e Any information provided by the terminal during the PDP startup procedure For example the terminal may provide a PDP type and or PDP address to the ME e A prior knowledge for example the ME may implement only one PDP type Using the Empty PDP type No PDP address or APN is sent in this case and only one PDP context subscription record is present in the HLR for this subscriber This command may be used in both normal and modem compatibility modes H3 Family AT Commands User Manual Page 270 of 375 FIDCCON Command Syntax Response Action Set ATD lt GPRS_SC gt CONNECT lt called_address gt lt L2P gt or lt cid gt ERROR The following tabl e shows the D 99 parameters lt Parameter gt Description lt GPRS_SC gt Digit string value 99 which identifies a request to use GPRS GPRS Service Code
168. dle gt AT MCST 1 OK atd035684423 MCST 17 OK MCST 17 OK MCST 3 MCST 17 NO CARRIER MCST 1 H3 Family AT Commands User Manual Page 87 of 375 FIDCCON 5 5 Call Advice of Charge Commands This set of commands enables GSM operators to offer Advice of Charge AoC services that calculate call charges These charges are expressed in terms of home units 5 5 1 CAOC Advice of Charge This command displays information about the cost of calls If supported this command also activates deactivates unsolicited event reporting of the CCM Current Call Meter information The unsolicited report CCCM lt ccm gt is sent when the CCM value changes but not more than once every 10 seconds Note The CCM value depends on the network properties charge for MO or and MT calls There are two states in which the command can be activated In IDLE state returns the last call cost A voice data state returns the accumulated cost including the current call Command Syntax Response Action Remarks Set CAOC lt mod CAOC lt ccm gt The Set command returns the CCM e gt OK value from the H3xx or activates deactivates unsolicited or reports CME ERROR lt err gt Read CAOC CAOC lt mode gt The Read command returns the CAOC OK current CAOC mode or CAOC lt ccm gt or CME ERROR lt err gt Test CAOC CAOC list of The Test command returns the supported lt
169. du gt See description in the table below lt oa da gt Original destination address lt data gt Message contents in text mode lt toda toda gt Type of origination address destination address H3 Family AT Commands User Manual Page 149 of 375 FIDCCON lt fo gt First octet of the SMS lt pid gt Protocol Identifer lt dcs gt Data Coding Scheme lt sca gt Service Center Address lt tosca gt Type of Service Center Address Validity Period Either in integer format or in time string format lt vp gt yy MM dd hh mm ss zz lt mr gt Message reference lt scts gt Service center time stamp lt ct gt Command type lt sn gt Message serial number lt mn gt Message Number lt cdata gt Command Data lt mid gt Message ID lt page gt Current page number lt pages gt Total number of pages lt mr gt Message reference lt ra gt Message Recipient address lt tora gt Type of Recipient address lt scts gt Service center time stamp lt dt gt Discharge Time lt st gt Status H3 Family AT Commands User Manual Page 150 of 375 FIDCCON Example AT CPMS CPMS SM 13 50 SM 13 50 SM 13 50 OK AT CMGR 1 CMS ERROR invalid index AT CMGR 142 CMGR STO SENT 054565034 message text OK AT CSDH 1 OK AT CMGR 142 CMGR STO SENT 054565034 129 25 0 0 05 04 03 21 22 23 08 97254120
170. e problem when FTP is abnormal if FTP works fine unsolicited indication is disabled Command Syntax Response Action Remarks Set FTPINFO lt indica OK Enables disables FTP unsolicited tion gt Or ERROR indication lt error_code gt 0 Indication disabled 1 Indication enabled When indication is enabled module will send user all FTP commands and response by the following format FTPINFO lt data gt Read FTPINFO FTPINFO Returns FTP indication status lt indication gt OK 0 Indication disabled 1 Indication enabled Test FTPINFO FTPINFO range of Return command format supported lt indication_status gt s OK H3 Family AT Commands User Manual Page 347 of 375 FIDCCON The following table shows the FTPINFO parameter lt Parameter gt Description Indication status Enable disable FTP unsolicited indication the range of the value 0 1 Example at ftpinfo 1 enable unsolicited indication print OK AT FTPOPEN ftp adobe com anonymous ftpuser adobe com OK FTPINFO 220 ftp adobe com unsolicited indication returned by the server FTPINFO 220 Adobe Systems Inc FTPINFO 220 FTPINFO 220 By downloading software of Adobe Systems Incorporated or its FTPINFO 220 subsidiaries from this site you agree to the terms and FTPINFO 220 conditions described in ftp ftp adobe com license txt FTPINFO 220 FTPINFO 220 Web browser user
171. e 143 of 375 FHiIDCCON 7 1 14 CMGL List Messages These commands display a list of all SMS with the status value lt stat gt from the H3xx message storage lt mem1 gt selected using the CPMS command The command returns a series of responses one per message each item containing the message index status and data If the status of a message is RECEIVED UNREAD execution of the CMGL command changes the status of the message to RECEIVED READ Command Syntax Response Action Remarks Set CMGLI lt stat gt If text mode CMGF 1 command execution is successful and SMS SUBMITs and or SMS DELIVERs CMGL lt index gt lt stat gt lt oa da gt lt scts gt lt tooa tod a gt lt length gt lt CR gt lt LF gt lt data gt lt CR gt lt LF gt CMGL lt index gt lt stat gt lt da oa gt lt scts gt lt tooa tod a gt lt length gt lt CR gt lt LF gt lt data gt The parameters lt tooa toda gt lt length gt refer command shows the Text Mode Parameters CSDH and will be shown according to CSDH settings If text mode CMGF 1 command execution is successful and SMS COMMANDs CMGL lt index gt lt stat gt lt fo gt lt ct gt lt CR gt lt LF gt CMGL lt index gt lt stat gt lt fo gt lt ct gt If text mode CMGF 1 command execution is successful and CBM storage CMGL lt index gt lt stat gt lt sn gt lt mid gt lt page g
172. e 177 of 375 FIDCCON Test AT CREG CREG list of supported lt n gt s OK The following table shows the CREG parameters lt Parameter gt Description lt n gt 0 Disables the network registration unsolicited result code 1 Enables the network registration unsolicited result code CREG lt stat gt 2 Enables the network registration and location information in unsolicited reports and Read command CREG lt stat gt lt lac gt lt ci gt lt AcT gt The default value is 0 lt stat gt 0 Not registered and the ME is not currently searching for a new operator to register 1 Registered home network 2 Not registered but the ME is currently searching for a new operator to register 3 Registration denied 4 Unknown 5 Registered roaming lt lac gt Two byte location area code in hexadecimal format lt ci gt Four byte cell ID in hexadecimal format lt AcT gt 0 GSM 2 UTRAN 3 GSM w EGPRS 4 UTRAN w HSDPA 5 UTRAN w HSUPA H3 Family AT Commands User Manual Page 178 of 375 FIDCCON 6 UTRAN w HSDPA and HSUPA Note lt Act gt is supporting only in R7 Protocol Stack AcT values 3 4 5 6 options are supported only in R8 PS Example AT CREG CREG 0 2 OK AT CREG CREG 0 1 OK AT CREG 2 OK AT CREG CREG 2 1 A52F 01603413 6 OK AT CREG 1 OK AT CREG CREG 1 1 O
173. e Disable wake up host FUNCTION eceeceesseeeseeeeseeseseeseseeseeeeeeseeeeseees 226 NOS WAR TZ COMMOUMATION a airen ceieesdeisandvesdseddea tossed a E tee sdnadvese 227 10 3 1 UART2 use for AT SGMUTIEME 2 2 caceccorsasnapeatansarsacateeae cee teaveataoeacescacecantea seaucatneeaestextqtasenaraeuanieaneaue 227 10 3 2 UARTSEND Send data to UART 2 0 0 ccccesescsseseeesseeesesensesecseseeecsccecsecaesesaeseeseeeesesaeeeseeeees 227 10 4 Multiplexer Feature soren a TE R E EE E 228 10 4 1 CMUX MUX Startup COMMANG 0 cece ccccccsscscesscscssceecsecsecsecseesecsesscssesecssesecsesseesesecesssecsecaes 229 10 5 Clock COmbiQuratiOn sissies anert ones stevia E E A EA E EEEE E EEREN 231 10 5 1 CLKOUTO 26MHz Clock Output From CLKOUTO Q 0 ccc cccsccccseeneeseeseesceseecseeseensesees 231 10 5 2 CLK32k 32KHz Clock Output From CLK32K ccc cccccccccssccscsecsecseesecseesececssceecseceesseeneeaes 232 10 5 3 CLKFSYS1 26MHz Clock Output From CLKFSYS1_ 26M ee cccceeseseeseeeceeeeeeeeeeeseees 232 10 6 BODYSAR Feat re sirina a ra a E NE O aE E a o NR r aE E aa S 233 10 6 1 BODYSARGSM Set Max Tx Power Threshold For GSM esessieerrierirsierierrerirererrrsreen 233 10 6 2 BODYSARWCDMA Set Max Tx Power Threshold For WCDMA 235 10 6 3 BODYSARON Switch On Off BODYSAR Function cece eeseseseseseeeseeeseseeeseseseaeaees 236 TU PCO s erna n a a EE E 238 A We SCOP CS n EAE A A A beaeaesteniateaetes 238 H3 Family AT Commands User Manual
174. e TP RP and TP UDHI settings will be taken from the incoming message s first octet lt vp gt will be set to the default value 167 as defined in 03 40 lt sca gt lt tosca gt lt pid gt and lt dcs gt will be set according the incoming message parameters If lt da gt and or lt toda gt are not given by the command the lt oa gt and lt tooa gt will be set instead Command Syntax Response Action Remarks Set CMSS lt inde CMSS lt mr gt The Set command sends a message x gt lt da gt lt tod or from storage to the network a gt CMS ERROR lt err gt The following table shows the CMSS parameters lt Parameter gt Description lt index gt 1 352 Index in storage of the message to be sent H3 Family AT Commands User Manual Page 152 of 375 FIDCCON lt da gt Destination address in quoted string This field contains a single phone number lt toda gt Type of DA Value between 128 255 according to GSM 03 40 9 1 2 5 If this field is not given and first character of lt da gt is lt toda gt will be 145 otherwise 129 lt mr gt Sent message reference number Example AT CMSS 7 CMSS 12 OK AT CMSS 7 054565132 129 CMSS 13 OK Note Any character sent by TE to H3xx before H3xx has reported a result of AT CMSS operation will abort AT CMSS command execution However if SMS was already sent to network and sending operation was
175. e data is being sent to Network after a spooling timeout 50 mS otherwise the data is being sent to Network immediately Only one socket is allowed at the same time in Online Data Mode The MIPODM command returns a MIPSTAT lt Socket_ID gt lt Error gt unsolicited event if it fails For example if it was rejected by the remote side Command Syntax Response Action Remarks Set AT MIPODM OK The Set command returns lt Socket_ID gt or lt Remote IP gt and lt Remote lt Source Port gt Port gt parameters only for MIPODM lt Socket_ID gt H3 Family AT Commands User Manual Page 340 of 375 FIDCCON lt Remote IP gt lt State gt lt Remote IP gt lt Remote Port gt lt Remote Port gt lt Protocol gt or MIPSTAT lt Socket_ID gt lt Status gt or ERROR lt err gt sockets opened in Listen mode lt socket_ID gt s list of supported lt source port gt s list of support d lt Destination lP gt s list of lt destination port gt s list of supported lt protocol gt s list of supported lt Pseudo Command Mode state gt s Read AT MIPODM MIPODM lt Socket_ID gt When a socket opens in for each socket that can be Online Date Mode Ane command returns actual opened Socket_ID value a d 1 value or active H3xx will be in MIPODM 0 0 pseudo command mode for if there are no free sockets receiving the command Test
176. e forward them directly to the TE 2 buffer unsolicited result codes in the MT when MT TE link is reserved e g in on line data mode and flush them to the TE when MT TE link becomes available otherwise forward them directly to the TE lt bfr gt 0 MT buffer of unsolicited result codes defined within this command is cleared when lt mode gt 1 or 2 is entered 1 MT buffer of unsolicited result codes defined within this command is flushed to the TE when lt mode gt 1 or 2 is entered OK response shall be given before flushing the codes 2 circuit switched preferred use Packet Domain if circuit switched not available Example AT CGEREP 1 0 OK AT CGEREP 2 2 ERROR AT CGEREP CGEREP 0 2 0 1 OK AT CGEREP 2 0 AT CGEREP CGEREP 2 0 OK H3 Family AT Commands User Manual Page 300 of 375 FIDCCON 12 2 18 CGTFT Traffic Flow Template This command allows the TE to specify a Packet Filter PF for a Traffic Flow Template TFT that is used in the GGSN for routing of down link packets onto different QoS flows towards the TE Command Syntax Response Action Remarks Set CGTFT lt cid gt lt packet filter OK The set command identifier gt lt evaluation ERROR specifies a Packet Filters precedence index gt lt source MALIE OUE gee Tohe address and subnet mask gt TET sored MoE MT And lt protocol number ipv4 used TOMIE COMER next header ipv6 gt identified by the l
177. e gt OK The Read command returns the current activation states for all the defined PDP contexts Test AT CGACT CGACT list of supported lt state gt s OK The Test command requests information on the supported PDP context activation states The following table shows the CGACT parameters lt Parameter gt Description lt state gt Indicates the activation state of the context 0 Non active 1 Active lt cid gt 1 10 Anumeric parameter that specifies a particular PDP context definition Example AT CGACT CGACT 0 1 OK AT CGACT OK H3 Family AT Commands User Manual Page 273 of 375 FIDCCON AT CGACT 1 ERROR GPRS network not present Note In some GPRS networks CGACT is not supported the ATD 99 command can be used to establish a connection Activating a context can take up to 150 seconds Deactivating a context can take up to 40 seconds When aborting a CGACT Set command the context is closed This can take up to 40 seconds 12 2 8 CGPADDR GPRS ADDResses This command reads the allocated PDP addresses for the specified context identifiers Command Syntax Response Action Remarks Set AT CGPADDR lt cid gt CGPADDR The Set command returns a lt cid gt lt cid gt lt PDP_addr gt lt CR gt lt list of PDP addresses for the LF gt specified context identifiers CGPADDR lt cid gt lt PDP_addr gt
178. e gt specified then no channels are the cell broadcast lt mids gt lt accepted and the H3xx message type and data dcss gt channel mid list is cleared coding scheme OK or CME ERROE lt err gt n Read CSCB CSCB The Read command amode gt smiles sdcesr displays the current MID OK and DCS settings lj Test CSCB 7 CSCB list of supported The Test command lt mode gt s displays the supported OK values of lt mode gt Note The Channel and DCS list is saved to the SIM card The maximum number of active channels is SIM dependent The AT CSCB set command is not available when the phone is either in Emergency Only or No Service status The following table shows the AT CSCB parameters H3 Family AT Commands User Manual Page 160 of 375 FIDCCON lt Parameter gt Description lt mode gt The current broadcast message mode 0 MIDs and DCSs accepted 1 MIDs and DCSs not accepted lt mids gt Cell broadcast message identifiers 0 65534 lt dcss gt Cell broadcast message data coding schemes 0 255 Note e A combination of discrete values or intervals can be entered for lt mids gt and lt dcss gt for example 0 1 5 320 324 922 e The default value for missing lt mode gt is 1 e The string type lists lt mids gt and lt dcss gt may include only numbers 0 9 comma and minus characters e lt mids gt 1 5 is equivalent to fi
179. e indicating the maximum length of field lt adnumber gt lt slength gt integer type value indicating the maximum length of field lt secondtext gt lt elength gt integer type value indicating the maximum length of field lt email gt Example AT CPBS SM OK AT CPBR CPBR 1 250 20 14 OK At CPBR 1 H3 Family AT Commands User Manual Page 111 of 375 FIDCCON AT CPBR 1 3 There is nothing written in entry 1 2 3 OK AT CPBR 4 CPBR 4 18888888 129 Tom OK 6 1 3 CPBF Find Phone Book Entries This execution command enables the user to search for a particular entry by name in the currently active phone book If no matching entry is found the command returns OK If multiple matches are found all are returned Command Syntax Response Action Set CPBF lt f CPBR indtext gt lt index1 gt lt number gt lt type gt lt text gt lt hidden gt lt group gt lt ad number gt lt adtype gt lt secondtext gt lt email gt lt CR gt lt LF gt CPBR lt index2 gt lt number gt lt type gt lt text gt lt hidden gt lt group gt lt ad number gt lt adtype gt lt secondtext gt lt email gt OK or CME ERROR lt err gt Test AT CPBF CPBF lt nlength gt lt tlength gt lt glength gt lt slength gt lt elength gt OK The following table shows the CPBF parameters lt Parameter gt Description lt findtext gt C
180. e is optimised 0 conversational 1 streaming 2 interactive 3 background Other values are reserved lt Maximum bitrate Anumeric parameter that indicates the maximum number of kbits s delivered to UL gt UMTS up link traffic ata SAP As an example a bitrate of 32 kbit s would be specified as 32 e g CGEQNEG 32 refer TS 24 008 subclause 10 5 6 5 lt Maximum bitrate A numeric parameter that indicates the maximum number of kbits s delivered DL gt by UMTS down link traffic ata SAP As an example a bitrate of 32 kbit s would be specified as 32 e g CGEQNEG 32 refer TS 24 008 subclause 10 5 6 5 H3 Family AT Commands User Manual Page 292 of 375 FIDCCON lt Guaranteed bitrate UL gt A numeric parameter that indicates the guaranteed number of kbits s delivered to UMTS up link traffic at a SAP provided that there is data to deliver As an example a bitrate of 32kbit s would be specified as 32 e g CGEQNEG 32 refer TS 24 008 subclause 10 5 6 5 lt Guaranteed bitrate DL gt A numeric parameter that indicates the guaranteed number of kbits s delivered by UMTS down link traffic at a SAP provided that there is data to deliver As an example a bitrate of 32 kbit s would be specified as 32 e g CGEQNEG 32 refer TS 24 008 subclause 10 5 6 5 lt Delivery order gt Anumeric parameter that indicates whether the UMTS bea
181. e of the H3xx 0 new call play tone default 1 new call Silent mode ring prevented lt smsmode gt 0 newsms play tone H3 Family AT Commands User Manual Page 242 of 375 FIDCCON 1 newsms Silent mode ring prevented Note Selecting the ring mode with this command retrieves the current alert volume level setting 11 2 7 VTD Tone Duration This command handles the selection of tone duration An integer lt n gt defines the length of tones emitted as a result of the VTS command This command does not affect the D dial command In this command the new value is saved after power down Note In GSM the tone duration value can be modified depending on the specific network Command Syntax Response Action Remarks Set VTD lt n gt OK The Set command sets the tone duration or CME ERROR lt err gt Read VTD VTD lt n gt The Read command displays the OK current tone duration Test VTD VTD list of supported The Test command displays the list of lt n gt s supported tone durations OK The following table shows the VTD parameters lt Parameter gt Description lt n gt Defines the length of tones emitted by the VTS command 1 10 100mS to 1S adjustable 11 2 8 VTS Command Specific Tone Duration This command transmits a string of DTMF tones when a voice call is active DTMF tones may be used for example when announci
182. ed for Read command only do not attempt registration deregistration 4 Manual automatic lt oper gt field is present if manual selection fails Page 183 of 375 FIDCCON lt format gt The operator format type 0 Long alphanumeric 1 Short alphanumeric 2 Numeric The default value is 0 lt stat gt 0 Unknown 1 Available 2 Current 3 Forbidden lt oper gt Operator name displayed The long alphanumeric format can be up to 16 characters long The short alphanumeric format can be up to 8 characters long The numeric format is the GSM Location Area Identification number refer to GSM 04 08 subclause 10 5 1 3 consisting of a three BCD digit country code as per ITU T E 212 Annex A plus a two BCD digit network code which is administration specific The returned lt oper gt is not in BCD format but in IRA characters converted from BCD and therefore the number has the following structure country code digit 3 country code digit 2 country code digit 1 network code digit2 network code digit 1 lt AcT gt Indicates the radio access technology and values can be 0 GSM 2 UMTS lt plmn_list gt Indicates whether the PLMN is present on the EHPLMN list the User Controlled PLMN List or the Operator Controlled PLMN List 0 PLMN is present on the EHPLMN list 1 PLMN is present on the User Controlled PLMN List H3 Family AT Commands User Manual Page 184 of 375 FIDCCON
183. eeeeseeeeeeeecseeesseeseseeseseeeeeeeeeeeeseses 305 12 2 20 CGEV Unsolicited Packet Domain Event Reporting ccccccccccssccscsecsscseeseeeeeseeeeseesees 306 13 TCP IP crenn a E E dean E E iota die tele 308 13 1 MIPCALL Create a Wireless LINK ccccccccescssesessesesecseecseseeseeesseeesesscsesecaesecaesesseeeseeeseeeeeesaeeees 308 13 2 MIPOPEN Open a Socket UDP or TCP ccccccccccccccsscseesecseeseeecsecsecsecsecsecseesecsesscaesecseseeseeseens 309 13 3 MIPCLOSE Close amp Socket cccesecssssecesssseseseecssssescaesescsceneeescsssnesesesceceacsecesseceesseeessecensseeeeeaseeneees 312 13 4 MIPSETS Set Size and Timeout for Automatic PUSH ecccceseseeeeseeeeseseeseeenseeeeseeeeeeeeeateeeaes 314 13 5 MIPDSETS Set Size and Timeout for Output Data ce cccccesscescsecsecsecsecsceseeecseceecseeeeaes 316 13 6 MIPSEND Send Data i cessisccsecsistvdeszesctiaceestsaesans a E E E EE 318 13 6 1 Send Data at normal MOE cccccceceseseeseseeeeseeceseeecsesseseaesesecsesecsesecsecesseeaeseeseseesaeeeeseeesaeaes 318 13 6 2 Send Data at HEX Mode ccecceseseseseeeseseseseeesseceecscecseacseseeesseeescaesesaescseeeesaeeeeeeseesaeeeseneeeaees 319 13 7 GTSET Set receive data MOC eeceeesssesesecesesesesesesceceecsesesesecseseseeseeeseaesseceecaceeseeaeeeaeeeeeeeeetaeeees 322 13 8 MIPPUSH Push Data into Protocol Stack cccccccssesessesssesseseeseseeseseeecseeecseeeesesseseesesesseeeneeeeeeees 324 13 9 MIPFLUSH Flush Data from B
184. end DTMF to the network by VTS Note For H350 xxx 10 H380 this commands is not supported Command Syntax Response Action Remarks Set VTA lt para gt OK Enable Disable play DTMF at local side or ERROR H3 Family AT Commands User Manual Page 244 of 375 FIDCCON Read VTA VTA lt para gt OK or ERROR Query status Test VTA VTA lt para gt OK or ERROR The following table shows the VTA parameters lt Parameter gt Description lt para gt 0 Disable play DTMF tone at local side 1 Enable play DTMF tone at local side Default value Example AT VTA VTA 1 OK AT VTA VTA 0 1 OK 11 2 10 MAPATH Audio Path This command sets requests the active input accessory and the output accessory for each feature On power up the default path mic speaker and alert speaker are restored As CODEC supports two chips which are CS42L73 and ALC5621 so the configuration of this parameter is related to command GTCODECN Note For H350 xxx 10 this commands is not supported Command Syntax Response Action Remarks H3 Family AT Commands User Manual Page 245 of 375 FIDCCON Set MAPATH OK The Set command sets the audio lt direct gt lt accy gt 6 path mode The mode indicates which I O accessories are now active CME ERROR lt err gt for the differen
185. eport out off the Low boundary after 30 seconds Unsolicited report out off the High boundary after Nx30 seconds Read the current setting MTSM 3 30 10 40 OK AT MTSM 0 OK AT MTSM MTSM 0 OK Set to stop the unsolicited report Read the current setting 10 2 6 WRIM RI signal width setting In IDLE Mode H3xx s RI pin is High voltage level When H3xx receive a SMS or Call This pin can output a Low voltage pulse This command defines the width of pulse can be set Command Syntax Response Action Remarks Set WRIM lt ty OK Set width pe gt lt width gt or ERROR Read WRIM WRIM lt type gt lt width gt The read command returns the OK current parameter of RI pin or ERROR Test WRIM WRIM lt type gt lt width gt The test command displays the list OK of supported lt type gt and lt width gt values or ERROR H3 Family AT Commands User Manual Page 220 of 375 FIDCCON The following table shows the WRIM parameters lt Parameter gt Description lt type gt 0 make effective on Call 1 make effective on SMS lt width gt 0 default value 0 1000 and 1 150 1 2000 1 2000ms Example AT WRIM WRIM 0 1 0 2000 OK AT WRIM 1 1000 OK AT WRIM WRIM 0 1000 WRIM 1 1000 OK 10 2 7 MSTART Start message notification This command can Enable Disable H3xx output start message when po
186. eric letters or the hyphen There is no default value appropriate ERROR will be displayed if parameter is not supplied lt count gt Specifies a number of Internet Control Message Protocol ICMP Echo Request messages to send Valid value range is from 1 to 255 H3 Family AT Commands User Manual Page 333 of 375 FIDCCON The default value is 4 lt size gt Specifies the length in bytes of the Data field in the Echo Request messages sent The minimum size is 0 The maximum size is 1372 The default value is 32 lt TTL gt Time To Live TTL Specifies number of hops hop is one step from one router to the next on the path of a datagram on an IP network which the Echo Request message may be routed over The value is set by using TTL field in IP header Valid value range is from 1 to 255 The default value is 64 lt TOS gt The Type Of Service TO S is for internet service quality selection The type of service is specified along the abstract parameters precedence delay throughput and reliability These abstract parameters are to be mapped into the actual service parameters of the particular networks the datagram traverses Minimum and maximum values for TOS are 0 and 255 respectively Refer to RFC 791 and RFC 2474 which obsoletes RFC 791 for TOS defined values The default value is 0 lt TimeOut gt Specifies the amount of time in milliseconds to wait for the
187. erted by an incoming call from the network Once this indication is sent information is available on the calling line via CLIP H3 Family AT Commands User Manual Page 57 of 375 FIDCCON When CRC is disabled the indication is RING and when CRC is enabled the indication is CRING Command Syntax Response Action Remarks Set CRC lt n gt OK The Set command enables disables the extended format of an incoming call indication When enabled an incoming call is indicated to the terminal with an unsolicited result code CRING lt type gt instead of the normal RING Read CRC CRC lt n gt OK The Read command queries the current settings for the cellular result code Test CRC CRC list of supported lt n gt s The Test command returns the possible lt n gt values RING CRING Indication CRING lt type gt or RING The following table shows the CRC parameters SYNC REL ASYNC lt priority gt lt subaddr gt lt satype gt lt priority gt lt subaddr gt lt satype gt lt priority gt lt subaddr gt lt satype gt lt Parameter gt Description lt n gt 0 Extended format disabled 1 Extended format enabled The default value is 0 lt type Type of incoming call ASYNC asynchronous transparent synchronous transparent asynchronous non transparent H3 Family AT Commands User Manual Page 58 of 375
188. es and use numeric lt err gt values or STK ERROR lt err gt result codes and use numeric lt err gt values 2 Enable the CME ERROR lt err gt or CMS ERROR lt err gt result codes and use verbose lt err gt values or STK ERROR lt err gt result codes and use H3 Family AT Commands User Manual Page 46 of 375 FIDCCON numeric lt err gt values The default value is 0 Example AT CMEE 0 CME ERROR is not used OK AT VTD ERROR AT CMEE 1_ Use numeric lt err gt OK AT VTD CME ERROR 1 AT CMEE 2 Use verbose lt err gt OK AT VTD CME ERROR operation not supported 4 3 2 CEER Extended Error Report This execution command returns an extended error report containing one or more lines of information text lt report gt determined by the manufacturer providing reasons for the following errors Failure in the last unsuccessful call setup originating or answering or the in call modification Last call release Typically the text consists of a single line containing the reason for the error according to information given by GSM network in textual format Command Syntax Response Action lt Execute AT CEER CEER lt category gt lt cause gt lt description gt OK Test AT CEER OK The following table shows the CEER parameters lt Parameter gt Description lt category gt No report available
189. esecseneneeseecseeseeeeeeeaeeeeeeees 14 2 1 AT Commands OVErView ccccescesesscesessesececescscecesesesseseesecesseceseaesescsnencsescecsaeseseseeseseseaeaseceaseceeetaeeeeeaeees 14 2 2 General System Abbreviations ccccccesescsseseseeseseesesesseseeecseecsececsecanseceseaeaeseeseeecsececsenseseeseseneseeeessesees 14 2 9 AT Commands Protocol sseni ea E E O EE T E EES 14 2 4 AT Commands StTUCtU Ocet arcee E E E e e R EEE 15 2 4 1 General Symbols Used in AT Commands DeSCTip tion ceseseeseeeeeeseeeceeeeseeseseeeeeeeeeaeeees 15 24 2 Command StrUCture c iccdessssceccadatehsnestelazeadacves dies ana e ae E N EE e E 16 2 4 3 Results Code Structure cnccsssssscssssaecussssssecstscasedesssascseasdececdnasnsessacabesansvaseasadeddedesdasascdeadedensuadendenensseaes 16 2 5 COMMANGSVMAX 22 5 dccseescassdpheceeshesnsestietecedeetisessnyyessebihenes cadeneudedsnssastegadesyaadsaws tas dlestassGeeceasetagivensseafheyelbenedehse 17 3 Modem IDin nnani a sili silage REEE Eaa aae e aa anaia i E 18 3 1 CGMI GMI FMI Request Manufacturer ID ccc ccccecccescsecnecseesecseeseeseescesessceesecsscseesessceseeeeees 18 3 2 CGMM GMM FMM Request Model ID cececceessesesseseseeseseeseseeseseeeseecsesecseeecsesenseeeeseeesaeeesaeees 18 3 3 CGMR GMR FMR Request ReVISION ccccccccecsccsessessescesssscesesecsscsecsecsecsecsceseeecacsecseceeseeneesees 19 3 4 CGSN GSN Request Product Serial Number Identification ccc ceceesees
190. eseeseteeeeeeeseeenseneeeens 20 3 5 CSCS Select Terminal Character Sete ccccccccesssssseeseseeecseesesesecsesensesensceececsecaeseesesesseeeeeeeanseeeeeeseeaes 21 3 6 FCM Request M S netlist asain ee eS 22 3 7 CFSN Read Factory Serial NUMDEM Qu ccc ccc ccesccscssceecseceesecsecseesesscssesecseesecssesceseecsacsecsecseesecseeaes 22 3 8 Request Identification INforMation cc ccecccesccssssecsssscescsecsscsecsecsecsecsessesecsscsecsecsecsecsecsceseseeseeseesaeaes 23 3 9 CNUM Request MSISDN S cccccccccscesscscessescssceecsecsecsecsessessesscssesecssesecsseseessacacsecsacsecsecsecsecaceseeeeseses 24 3 10 CLAC List of All Available AT Command cesceesssessesesesesesseseeesesesesceeesesenesaesesceeeenscseneeeeaneeaeeees 25 4 Modem Control and Status 0 ccccs scccssccdsccesssegiesavensenssceecaneseccuutasdathscudssderecsedenadedciiesvastectazsientegesgaecusescedtlanatenved ersesee 26 4 1 Modem Register COMMAMNAS c ccccccccsesscsseseescescesesscsscsecsscsecsecssssesecsscsecsscsessecseaesesecseesecseesecseeseeseneeeess 26 4 11 V H3xx Response FoOrmattisiss iceicve ceeciteel ee lee ei evden ees 26 4 1 2 Q Result Code SUPPresSiOn cccssssssssssssssecessesescsesecsesessesessesessesseaesececsesauscsaeaseceeesseseeseseereas 27 413E Command ECMO sassen E O E EEEo EaR 28 4 1 4 X Result Code Selection and Call Progress Monitoring Control cceccceecseseeeseseeseeseees 29 4 1 5 S Bit Map
191. essssesesseseesesesceseseeseseeseeeeseseeseseceesecseseeseseeseeeeeeeateeaes 270 12 2 7 CGACT PDP Context Activate or Deactivate cceeececeseeeseeseeesceeeeeseseeeeeeeeseeeeeeeteeseees 272 12 2 8 CGPADDR GPRS ADDRESSES ccceccccsssesessssseesesesseeeesesesesceecsesessecsesesececsesesesesanseseeeesseees 274 12 2 9 CGANS Manual response to a network request for PDP context activation 275 12 2 10 CGAUTO Automatic Response to a Network Request for PDP Context Activation 277 12 2 11 CGEQMIN 3G Quality of Service Profile Minimum acceptable 279 12 2 12 CGEQREQ 3G Quality of Service Profile Requested ccc ccccsecceseceeeseeseneeees 285 12 2 13 CGEQNEG G Quality of Service Profile Negotiated cc cccceceeeseceeeseeneesees 291 12 2 14 CGCMOD PDP Context Modify ccccccseseesescseeseeeseseeseeeeecsseeesececsesseseeseseseseeecseeesaeees 294 H3 Family AT Commands User Manual Page 10 of 375 FIDCCON 12 2 15 CGDATA Enter Data State eecesseeesceeseeseeesesceeeecseseseeseseseaeeesanecaeeeeesseeeneeeneeseees 295 12 2 16 CGDSCONT Define Secondary PDP Context cccccessescsseeesseseeeseseeseeeeseenseseeeeaeeas 297 12 2 17 CGEREP Packet Domain Event Reporting ccccccccsecsceseseccsesscsssseesessceseseeees 299 12 2 18 CGTFT Traffic Flow Template ccc ccccccccccsccsessecsesecsseseceesecsesscesesecsecsecsecseesecssesseecsaeees 301 12 2 19 MGAUTH Set type of AUthentiCation cece cccscsseseese
192. eted time between request to transfer an SDU at one SAP to its delivery at the other SAP in milliseconds refer TS 24 008 subclause 10 5 6 5 lt Traffic handling Anumeric parameter 1 2 3 that specifies the relative importance for priority gt handling of all SDUs belonging to the UMTS bearer compared to the SDUs of other bearers refer TS 24 008 subclause 10 5 6 5 Example AT CGEQNEG CGEQNEG OK 12 2 14 CGCMOD PDP Context Modify The execution command is used to modify the specified PDP context s with respect to QOS profiles and TFTs Command Syntax Response Action Remarks Set CGCMOD OK The set command is used to lt cid gt lt cid gt modify the specified PDP Or Nl context s with respect to CME ERROR lt error gt QoS profiles and TFTs CGCMOD Test CGCMOD list of lt cid gt s associated The test command returns a with active contexts list of lt cid gt s associated with OK active contexts H3 Family AT Commands User Manual Page 294 of 375 FIDCCON The following table shows the CGCMOD parameters lt Parameter gt Description lt cid gt Anumeric parameter which specifies a particular PDP context definition see the CGDCONT and CGDSCONT commands Example AT CGDCONT CGDCONT 1 IP CMNET 172 29 107 202 0 0 CGDCONT 2 IP 0 0 0 0 1 1 CGDCONT 3 IP CMNET 0 0 0 0 0 0 CGDCONT
193. f address octet in integer format 145 Default when dialing string includes international access code character 129 Default when making a local call lt subaddr gt NULL field not used String type subaddress of format specified by lt satype gt lt satype gt Field not used Value is always 128 unknown type of sub address octet in integer format lt class gt The sum of integers each representing a class of information Please see class table in CCWA command H3 Family AT Commands User Manual Page 70 of 375 FIDCCON The default value is 7 lt time gt 1 30 The number of seconds to wait before calls are forwarded when no reply is enabled or queried The default value is 20 Note The parameter must be a multiple of 5 for example 5 10 15 and so on lt status gt 0 Not active 1 Active Note A forward to phone lt number gt and the optional fields lt type gt lt subaddr gt and lt satype gt are tied to a lt reason gt and a lt class gt This means that there can be a different lt number gt for the same lt reason gt because of a different lt class gt When registering without mentioning a lt class gt lt class gt 7 is selected A lt number gt field is mandatory when registering lt mode gt 3 and it is irrelevant ignored in all other lt mode gt s Example AT CCFC CCFC 0 1 2 3 4 5 OK AT CCFC 0 3 01256316830 129 1 OK AT CC
194. f all OK the services supported by the terminal The following table shows the CSMS parameters 0 Not supported by the H3xx lt Parameter gt Description lt service gt Integer that defines the type of service 0 SMS AT command grammar is compatible with GSM Phase 2 1 SMS AT command grammar is compatible with GSM Phase 2 lt mt gt Mobile terminated messages FIDCCON 1 Supported by the H3xx lt mo gt Mobile originated messages O Not supported by the H3xx 1 Supported by the H3xx lt bm gt Broadcast type messages 0 Not supported by the H3xx 1 Supported by the H3xx Example AT CSMS CSMS 1 1 1 1 OK 7 1 2 CPMS Preferred Message Storage This command handles the selection of the preferred message storage area The message storage area is divided into three parts mem1 mem2 and mem3 Command Syntax Response Action Remarks Set CPMS lt mem1 gt CPMS The Set command lt mem2 gt lt mem lt used1 gt lt total1 gt lt used2 gt lt total2 sets the memory 3 gt gt lt used3 gt lt total3 gt storage OK or CMS ERROR lt err gt Read CPMS CPMS The Read command lt mem1 gt lt used1 gt lt total1 gt lt mem2 displays the selected gt lt used2 gt lt total2 gt lt mem3 gt lt use memory storage type d3 gt lt total3 gt for the three memory areas OK H3 Family AT Commands User Manual Page 121 of 375 FIDCCON
195. for local call 145 Use for international access code 128 Unknown Example AT CNUM CNUM VoiceMail 13812345678 129 OK H3 Family AT Commands User Manual Page 24 of 375 FIDCCON 3 10 CLAC List of All Available AT Commands This command prints out all AT Commands supported by the H3xx Command Syntax Response Action Remarks Execute CLAC List of available AT commands The Execute command displays a list of all the AT commands supported by the H3xx H3 Family AT Commands User Manual Page 25 of 375 FiDCCON 4 Modem Control and Status 4 1 Modem Register Commands The H3xx holds certain data items in selected memory space named Software Registers S registers and Modem Registers Some of these registers are used as bitmaps where one register holds more than one data item All S registers can be accessed using the S command described in S Bit Map Registers Some registers can also be accessed using dedicated commands detailed below 4 1 1 V H3xx Response Format This command determines the response format of the data adapter and the contents of the header and trailer transmitted with the result codes and information responses This command also determines whether the result codes are transmitted in a numeric or an alphabetic verbose form The text portion of information responses is not affected by this setting The following table show
196. functionality For all Accessory AT commands besides SMS commands the CMEE set command disables or enables the use of result code CME ERROR lt err gt as an indication of an error relating to the functionality of the H3xx When enabled H3xx related errors cause a CME ERROR lt err gt final result code instead of the regular ERROR result code For all SMS AT commands that are derived from GSM 07 05 the CMEE Set command disables or enables the use of result code CMS ERROR lt err gt as an indication of an error relating to the functionality of the H3XX When enabled H3xx related errors cause a CMS ERROR lt err gt final result code instead of the regular ERROR final result Command Syntax Response Action Remarks Set AT CMEE OK The Set command enables or disables the lt n gt or use of result code CME ERROR lt err gt CME ERROR as an indication of an error relating to the lt err gt functionality of the H3xx Read AT CMEE CMEE lt n gt The Read command returns the current OK setting format of the result code Test AT CMEE CMEE list of The Test command returns values supported lt n gt s supported by the terminal as a compound OK value The following table shows the CMEE parameters lt Parameter gt Description lt n gt 0 Disable the CME ERROR lt err gt result code and use ERROR 1 Enable the CME ERROR lt err gt or CMS ERROR lt err gt result cod
197. g request execution is completed Four Echo Request messages were sent and four Echo Reply messages were received Average RTT is 417 milliseconds MPINGSTAT 0 10 170 4 112 4 4 417 13 15 MPINGSTAT Status Update for MPING Execution This is the unsolicited response that the H3xx sends to the terminal to inform of ping execution status update and provides summary statistics of ping request when ping request execution is completed Command Syntax Response Action Remarks Unsolicited MPINGSTAT The unsolicited response that the H3xx sends to Response lt status gt lt Destination the terminal to inform it with ping execution _IP gt lt SentMessages_ status update This response also provides a gt lt ReceivedMessages statistics summary of ping request when ping gt lt AverageRT T gt request execution is completed The following table shows the MPINGSTAT unsolicited response parameters lt Parameter gt Description lt status gt Specifies a status of ping request execution Defined values 0 The unsolicited response with this lt status gt will be sent to DTE upon completion of ping request If ping request was aborted or socket connection was terminated for any reason this unsolicited response will not be reported to DTE 1 The unsolicited response with this lt status gt will be sent to DTE if no ICMP reply message was received within timeout 2 The
198. ge Command Syntax Response Action Remarks Set AT CGQMIN lt cid gt lt OK The Set command specifies precedence gt lt delay gt a profile for the context lt reliability gt lt peak gt identified by the local lt mean gt Aa ane context identification parameter lt cid gt As this is the same parameter that is used in the CGDCONT command the CGQMIN command is effectively an extension of the CGDCONT command The QoS profile consists of a number of parameters each of which may be set to a separate value Read AT CGQMIN CGQMIN The Read command lt cid gt lt precedence gt lt delay gt lt r returns the current settings eliability gt lt peak gt lt mean gt lt CR_ for each defined context gt lt LF gt CGQMIN lt cid gt lt precedence gt lt delay gt lt r eliability gt lt peak gt lt mean gt OK or H3 Family AT Commands User Manual Page 265 of 375 FIDCCON CME ERROR lt err gt Test AT CGQMIN CGQMIN lt PDP_type gt list of supported lt precedence gt s list of supported lt delay gt s list of supported lt reliability gt s list of supported lt peak gt s list of supported lt mean gt s OK or CME ERROR lt err gt The Test command returns the parameter value ranges for each lt PDP_type gt The following table shows the CGQMIN parameters
199. gt lt dcs gt lt sca gt lt tosca gt lt ength gt lt CR gt lt LF gt If ME has its own display device then class 0 SMS and SMS in the message waiting indication group discard message may be copied to both ME display and to terminal In this case ME shall send the acknowledgement to the network Class 2 SMSs and messages in the message waiting indication group storage message result in indication as defined in lt mt gt 1 lt mt gt Class 3 SMS DELIVERs are routed directly to terminal using unsolicited result codes defined in lt mt gt 2 Messages of other data coding schemes result in indication as defined in lt mt gt 1 lt bm gt 0 No CBM indications are routed to the terminal default if CBM is stored in RAM NVRAM by ATC DR an indication of memory location is routed to DTE unsolicited result code CBMI lt mem gt lt index gt new CBMs are routed directly to the terminal using unsolicited result code CBM lt length gt lt CR gt lt LF gt lt pdu when PDU mode enabled gt or CBM lt sn gt lt mid gt lt dcs gt lt page gt lt pages gt lt CR gt lt LF gt lt data gt Class 3 CBMs are routed directly to TE using unsolicited result codes defined in lt bm gt 2 If CBM storage is supported messages H3 Family AT Commands User Manual Page 133 of 375 FIDCCON of other classes result in indication as defined in lt bm gt 1
200. he connection element lt ce gt to be err gt ame gt lt used when data calls are originated ce gt refer to GSM 02 02 Values may also be used during mobile terminated data call setup especially in the case of single numbering scheme calls Note For incoming calls the bearer service will be taken automatically from incoming parameters and not according H3 Family AT Commands User Manual Page 74 of 375 FIDCCON to the CBST Set command The H3xx does not change the output but for incoming calls the phone works in automatic mode lt speed gt s list of supported lt name gt s list of supported lt ce gt s OK Read AT CBS CBST T lt speed gt lt name gt lt ce gt OK Test AT CBS CBST list of The Test command returns values T supported supported by the MA as compound values The following table shows the CBST parameters lt Parameter gt Description lt speed gt 4 2400 bps V 22bis 5 2400 bps V 26ter 6 4800 bps V 32 7 9600 bps V 32 12 9600 bps V 34 14 14400 bps V 34 15 19200 bps V 34 16 28800 bps V 34 17 33600 bps V 34 0 Auto bauding automatic selection of the speed this setting is possible in case of 3 1 kHz modem and non transparent service H3 Family AT Commands User Manual Page 75 of 375 FIDCCON 39 9600 bps V 120 43 14400 bps V 120 47 19200 bps V 1
201. his command is used for enable digital audio or disable digital audio CS42L73 CODEC chip is installed in the module if the clients do not want to use the internal CODEC this command can output the digital signals directly Note For H350 xxx 10 H380 this command is not supported Command Syntax Response Action Remarks Set MADIGITAL lt X gt OK Configure to use interal r CODEC or not use interal CODEC output ERROR A the digital signal directly X set to be 0 use internal CODEC X equals to 1 output the digital signal directly Read MADIGITAL MADIGITAL X Return to the original OK settings return 0 if no configuration Test MADIGITAL MADIGITAL 0 1 Return OK if empty OK The following table shows the MADIGITAL parameters lt Parameter gt Description lt X gt X 0 use internal CODEC 1 output digital audio directly H3 Family AT Commands User Manual Page 256 of 375 FIDCCON Example AT MAIDIGITAL 0 use inside CODEC OK AT MAIDIGITAL 1 output digital signal directly OK AT MAIDIGITAL MAIDIGITAL 1 OK AT MAIDIGITAL MAIDIGITAL 0 1 OK Note AT MAIDIGITAL set to 1 MAPATH is invalid AT MAIDIGITAL set to 0 MAI2SY is invalid The setting is invalid when calling 11 3 2 MAI2SY Set Digital Audio to Transmit Parameters This command is used for setting digital audio to transmit the parameters including master
202. icit context activation request CGACT or in result of impl H3 Family AT Commands User Manual Page 306 of 375 FIDCCON icit context activation request associated to attach request CGATT 1 The format of the parameters lt cid gt lt cid_other gt are found in command CGDCONT lt reason gt integer type parameter indicates the reason why the co ntext activation request for PDP type IPv4v6 was not granted This parameter is only included if the requested PDP type associated with lt cid gt is IPv4v6 and the PDP type assigned by the network for lt cid gt is either IPv4 or IPv6 0 IPv4 only allowed 1 IPv6 only allowed 2 single address bearers only allowed 3 single address bearers only allowed and MT initiated context act ivation for a second address type bearer was not successful H3 Family AT Commands User Manual Page 307 of 375 FIDCCON 13 TCP IP 13 1 MIPCALL Create a Wireless Link This command sets up a PPP Point to Point Protocol connection with the GGSN Gate GPRS Support Node and returns a valid dynamic IP for the H3xx Note For H350 xxx 10 H380 No TCP IP commands are supported Command Syntax Response Action Set MIPCALL lt Operation gt lt APN gt lt cid OK 7 MIPCALL lt local IP address gt or ERROR lt err gt MIPCALL 0 Read MIPCALL MIPCALL lt status gt lt IP gt Test MIPCALL MIPCALL list of supported lt opera
203. ile on Remoter Server This command makes the server receive a file from data connection The data end of transmission character of this command is hexadecimal value 0 x03 If the data to be transferred is hexadecimal value 0 x03 and O x10 then escape characters 0 x10 must be added in front For example send hexadecimal 03 10 11 03 then should send 10 03 10 10 11 10 03 Note FTPSTOR command makes the server receive the data transmitted by data connection and store the data as file on the server site If the specified file in the path name already exists on the server site then this file will be replaced by transmitted data otherwise a new file will be created Command Syntax Response Action Remarks Set FTPSTOR lt fi OK FTPSTOR lt file_name gt is a complete qualified path and le_name gt lt result gt or file name on the server site lt Offset gt is the lt file_type gt lt ERROR file offset address already exists on the Offset gt lt error_code gt server this means the server support file transfer resume The command execution result return to the user as an unsolicited response 0 operation fails 1 operation success 2 connected already can upload data Read FTPSTOR ERROR Not supported Test FTPSTOR FTPSTOR lt file Return command format name gt 0 1 0 OxFFFFFFFE OK H3 Family AT Commands User Manual Page 360 of 375 FIDCCON The fol
204. ing locking and unlocking actions but not for querying The features of the H3xx that are affected by this are fixed dialing list When querying the status of a single call barring program lt mode gt 2 the lt status gt for each call type will be returned For lt fac gt SC SIM Card PIN setting and for lt fac gt FD SIM Fixed Dialing memory setting the lt class gt is irrelevant For more information about lt class gt refer to the following table shows the CLCK parameters For SC the lt passwd gt is SIM PIN For FD the lt passwd gt is SIM PIN2 Command Syntax Response Action Remarks Set CLCK lt fac gt For lt fac gt where lt class gt is The Set command lt mode gt lt pas irrelevant SC FD performs the specified swd gt lt classx CLCK lt fac gt 2 lt mode gt action on the gt specified lt fac gt CLCK lt status gt For lt fac gt with several supported lt class gt es CLCK lt fac gt 2 CLCK lt status gt lt class1 gt lt CR gt lt LF gt CLCK lt status gt lt class2 gt OK Read CLCK ERROR Test CLCK CLCK list of supported lt fac gt s The Test command returns the list of supported facilities H3 Family AT Commands User Manual Page 172 of 375 Bs FIBOCOM The following table shows the CLCK parameters lt Parameter gt Description lt fac gt Please see lt fac gt Table i
205. ion is present 0 phonebook entry not hidden 1 phonebook entry hidden lt group gt string type field of maximum length lt glength gt character set as specified by command Select TE Character Set CSCS lt adnumbe gt string type phone number of format lt adtype gt lt adtype gt type of address octet in integer format refer TS 24 008 subclause 10 5 4 7 lt secondtext gt string type field of maximum length lt slength gt character set as specified by command Select TE Character Set CSCS lt email gt string type field of maximum length lt elength gt character set as specified by command Select TE Character Set CSCS lt glength gt integer type value indicating the maximum length of field lt number gt lt alength gt integer type value indicating the maximum length of field lt adnumber gt lt slength gt integer type value indicating the maximum length of field lt secondtext gt lt elength gt integer type value indicating the maximum length of field lt email gt Example at cpbw 1 159867841 72 129 OK att cpbr 1 CPBR 1 15986784172 129 0 OK 6 1 5 CSVM Set Voice Mail Server This command handles the selection of the number to the voice mail server The new value should also remain after power cycle Command Syntax Response Action Remarks CSVM lt mod OK The Set command sets the Set e gt lt number gt CME ERROR number to the voice mail server lt type gt lt err gt Read
206. ional access code character 129 Default when making a local call 128 Type of number is unknown usually the output when the number itself is unknown lt status gt Call waiting support by the network output for lt mode gt 2 0 Not active 1 Active lt alpha gt Name of the calling party if provided by the network lt CLI validity gt The Validity of the Calling Line Identity presentation 0 CLI valid 1 CLI has been withheld by the originator 2 CLI is not available due to networking problems or limitations of the originating network Note When the parameter lt mode gt is 2 Query status the first parameter is ignored and the third parameter is always treated as class 1 unless it was set in Set Mode Example AT CCWA 1 Enable call waiting on H3xx H3 Family AT Commands User Manual Page 65 of 375 FIDCCON AT CCWA CCWA 0 1 OK AT CCWA CCWA 1 OK Examples of CCWA set command network interrogation AT CCWA 1 2 Class parameter is considered as 7 CCWA 1 1 Call waiting is active for class 1 voice OK AT CCWA 1 2 2 Class parameter is 2 CCWA 0 2 Call waiting is not active for class 2 data OK AT CCWA 1 1 OK Enable the call waiting feature in the network and in the H3xx Example CCWA indication atd9311234567 Originate a voice call OK OK Noice call connected conversation call waiting indication
207. is done through the memory command CPBS CPBS respectively The following table shows the D gt parameters lt Parameter gt Description lt alpha gt String type value which should be equal to an alphanumeric field in a phone book entry The used character set should be the one selected with Select Terminal Character Set CSCS lt alpha gt is case sensitive and should be placed in quotes alpha lt n gt This parameter is also called speed dial location It is an integer type memory location lt n gt should be in the range of locations available in the memory used lt mem gt This parameter is not case sensitive Example AT CPBS SM OK AT CSCS IRA OK AT CPBW 1 035659090 129 VoiceMail OK AT CPBR 1 CPBR 001 035659090 129 VoiceMail OK atd gt VoiceMail Phonebook by name OK OK ath H3 Family AT Commands User Manual Page 53 of 375 FIDCCON OK NO CARRIER 5 3 3 DL Dial Last Number The DL command places a voice call to the last number dialed The call progress information success failure is reported in the same way as for the Dial command Command Detailed Description ATDL Initial Response Last Number retrieved ATDL lt DIAL DIGITS gt 1st response Voice call placement begins OK 2nd response Voice call connected OK The following table shows the DL parameters lt Parameter gt Description semicolon If the semicolon
208. is set of commands enables control over supplementary service notifications including Structured and Unstructured Supplementary Service Data USSD data 5 6 1 CSSN Supplementary Service Notifications This command handles the enabling and disabling of supplementary service related network initiated notifications Command Syntax Response Action Remarks Set CSSN OK The Set command enables disables the lt n gt lt ar display of notification result codes to the m gt TE CME ERROR dares When lt n gt 1 and a supplementary service notification is received after a mobile originated call setup the CSSI notification is sent to the TE before any other mobile originated call setup result codes When several different notifications are received from the network each of them receives its own CSSI result code When lt m gt 1 and a supplementary service notification is received during a mobile terminated call setup or during a call or when a forward check supplementary service notification is received the unsolicited result code CSSU is sent to the TE In case of a mobile terminated call setup a CSSU is sent after every CLIP result code CLIP Calling Line Identification When several different events are received from the network each of them H3 Family AT Commands User Manual Page 96 of 375 FIDCCON receives
209. k by this MCELL indication format few senconds later MCELL lt screen_title gt lt CR gt lt LF gt lt screen_info gt lt CR gt lt LF gt The following table shows the MCELL parameters lt Parameter gt Description lt screen_title gt The requested screen title is written on the first line of each screen lt screen_info gt The requested screen information lt screen title gt Description lt screen num gt Serving Idle PI Idle Packet Idle mode Serving Cell Information screen x index cell Serving CS TBF Circuit Switched mode Serving Cell Information 2 screen Serving Misc Idle Packet Idle mode Miscellaneous Information 3 screen Uplink Transfer Dedicated TBF modes Uplink Data Transfer 4 screen Downlink Transfer Dedicated TBF modes Downlink Data Transfer 5 screen Adjacent Cell x Neighbor Cell Information screen 6 11 H3 Family AT Commands User Manual Page 196 of 375 FIDCCON Neighbors Neighbor Cells Summary screen 12 Reselection Re selection screen 13 Hopping Info Dedicated TBF modes Hopping Information 14 screen PDP Context PDP Context Information screen 15 18 GPRS Parameters Idle Packet Idle mode GPRS parameters 19 Sysinfos Idle Packet Idle mode Optional SYSINFO 20 Example AT MCELL OK AT MCELL MCELL 0 1 20 OK AT MCELL 0 3 OK MCELL Serving Misc P BCC
210. k personalisation PUK required network subset personalisation PIN required network subset personalisation PUK required service provider personalisation PIN required service provider personalisation PUK required corporate personalisation PIN required corporate personalisation PUK required hidden key required NOTE This key is required when accessing hidden phonebook entries EAP method not supported Incorrect parameters unknown Illegal MS Illegal ME GPRS services not allowed PLMN not allowed location area not allowed roaming not allowed in this location area GPRS services not allowed in this PLMN MSC temporarily not reachable Network failure Service not supported Service not subscribed service option temporarily out of order NS api already used Unspecified GPRS error PDP authentication error invalid mobile class Attach failure Invalid error mapping APN not listed in APN Control List ACL H3 Family AT Commands User Manual Page 368 of 375 FIDCCON 701 702 1001 1003 1006 1008 1016 1017 1018 1019 1021 1022 1026 1027 1028 1029 1030 1031 1034 1038 1041 1042 1043 1044 1047 1049 1050 1055 1057 1058 1063 1065 1068 1069 incorrect security code max attempts reached Unassigned unallocated number No route to destination Channel unacceptable Operator dete
211. k traffic at a SAP provided that there is data to deliver As an example a bitrate of 32kbit s would be specified as 32 e g AT CGEQREQ 32 If the parameter is set to 0 the subscribed value will be requested This parameter should be provided if the Traffic class is specified as conversational or streaming refer 3GPP TS 24 008 subclause 10 5 6 5 lt Delivery order gt A numeric parameter that indicates whether the UMTS bearer shall provide in sequence SDU delivery or not 0 no 1 yes 2 subscribed value Other values are reserved lt SDU error ratio gt a string parameter that indicates the target value for the fraction of SDUs lost or detected as erroneous SDU error ratio is defined only for conforming traffic The value is specified as mEe As an example a target SDU error ratio of 5 10 3 would be specified as 5E3 e g AT CGEQREQ 5E3 OE0 means subscribed value refer 3GPP TS 24 008 subclause 10 5 6 5 lt Residual bit error ratio gt a string parameter that indicates the target value for the undetected bit error ratio in the delivered SDUs If no error detection is requested H3 Family AT Commands User Manual Page 289 of 375 FIDCCON Residual bit error ratio indicates the bit error ratio in the delivered SDUs The value is specified as mEe As an example a target residual bit error ratio of 5 10 3 would be specified as
212. l Example AT GPIO 23 1 1 OK AT GPIO GPIO 23 0 1 52 0 1 Sieen Leave out some value here OK AT GPIO 23 2 GPIO 1 OK AT GPIO GPIO 23 52 53 73 74 75 76 89 106 107 108 0 2 0 1 OK H3 Family AT Commands User Manual Page 224 of 375 FHiIDCCON 10 2 10 GTFMODE Enable Disable hardware pin control flight mode This command is used to set hardware pin control flight mode to on or off When hardware pin control the flight mode is enabled If PIN8 is High voltage 1 8V the flight mode is turned off If PIN8 is low voltage the flight mode is turned on The default is High voltage Note For H330S H350 this command is not supported Command Syntax Response Action Remarks Set AT GTFMODE lt mode gt OK or ERROR Parameters are saved after power down Read AT GTFMODE GTFMODE lt mode gt E g GTFMODE 1 OK or GTFMODE 0 OK Test AT GTFMODE GTFMODE 0 1 OK The following table shows GTFMODE parameter description lt Parameter gt Description lt mode gt 0 hardware function is disable 1 hardware function is enable Example AT GTFMODE 1 OK AT GTFMODE GTFMODE 1 OK AT GTFMODE GTFMODE 0 1 OK H3 Family AT Commands User Manual Page 225 of 375 FIDCCON 10 2 11 GTWAKE Enable Disable wake up host function This command is used to set wake up host func
213. lass then the value is considered to be unspecified Example H3 Family AT Commands User Manual Page 284 of 375 FIDCCON AT CGEQMIN CGEQMIN 1 0 0 0 0 0 0 0 0E0 0E0 0 0 0 0 0 CGEQMIN 6 0 0 0 0 0 0 0 0E0 0E0 0 0 0 0 0 CGEQMIN 4 0 0 0 0 0 0 0 0E0 0E0 0 0 0 0 0 CGEQMIN 3 0 0 0 0 0 0 0 0E0 0E0 0 0 0 0 0 CGEQMIN 2 0 0 0 0 0 0 0 0E0 0E0 0 0 0 0 0 OK AT CGEQMIN CGEQMIN IP 0 3 1 63 in 1 kbps steps 64 568 in 8 kbps steps 576 8640 in 64 kbps steps 1 63 in 1 kbps steps 64 568 in 8 kbps steps 576 8640 in 64 kbps steps 8700 16000 in 100 kbps steps 1 63 in 1 kbps steps 64 568 in 8 kbps steps 576 8640 in 64 kbps steps 1 63 in 1 kbps steps 64 568 in 8 kbps steps 576 8640 in 64 kbps steps 8700 16000 in 100 kbps steps 0 1 10 1500 1502 1510 1520 1E6 1E5 1E4 1E3 7E3 1E2 1E1 6E8 1E6 1E 5 1E4 5E3 4E3 1E3 5E2 1E2 0 2 10 150 in 10 ms steps 200 950 in 50 ms steps 1000 4000 in 50 ms steps 0 3 0 1 0 1 OK 12 2 12 CGEQREQ 3G Quality of Service Profile Requested This command allows the TE to specify a UMTS Quality of Service Profile that is used when the MT sends an Activate PDP Context Request message to the network lt Maximum bitrate UL gt lt Maximum bitrate DL gt lt Guaranteed bitrate UL gt lt Guaranteed bitrate DL gt lt Delivery order gt lt Maximum SDU size gt lt SDU error ratio
214. les disables uplink and downlink voice muting during a CME ERROR lt err gt i voice call Read CMUT CMUT lt state gt The Read command returns the OK current uplink and downlink voice mute unmute state Test CMUT CMUT list of The Test command returns the supported lt state gt s possible lt state gt values OK The following table shows the CMUT parameters lt Parameter gt Description lt state gt 0 Unmute microphone and speaker path default 1 Mute microphone path Unmute speaker path 2 Unmute microphone mute speaker path 3 Mute microphone path mute speaker path Example AT CMUT CMUT 0 3 OK AT CMUT CMUT 0 uplink voice is unmuted OK AT CMUT 1 uplink voice is muted OK AT CMUT CMUT 1 OK AT CMUT 4 H3 Family AT Commands User Manual Page 240 of 375 FIDCCON CME ERROR lt err gt 11 2 4 S94 Sidetone Effect This command reduces the microphone audio input that is routed to the selected speaker so that people speaking will hear themselves talking Command Syntax Response Action Remarks Set ATS94 lt n gt OK The Set command sets the sidetone or status CME ERROR lt err gt Read ATS94 lt n gt The Read command returns the OK sidetone status The following table shows the S94 parameters lt Parameter gt Description lt n gt 0 7 Sidetone range 0 is lowest sidetone not mute The default v
215. licited report Default value 0 Celsius Setting corresponding lt Low gt and lt High gt temperature boundaries for lt Report gt 3 only lt High gt 0 125 The Highest boundary level of the temperature value for unsolicited report Default value 0 Celsius Setting corresponding lt Low gt and lt High gt temperature boundaries for lt Report gt 3 only Example AT MTSM II Test the range of the parameters MTSM 0 3 6 9 1 255 40 125 OK AT MTSM 1 II Set to read for once the current temperature measurement MTSM 35 Current temperature is 35 Celsius degree OK AT MTSM 2 5 Set to unsolicited temperature reports to TE for every 5 seconds OK MTSM 10 Current temperature measure report 10 Celsius MTSM 5 Unsolicited temperature report 5 Celsius after 5 seconds MTSM 7 Unsolicited temperature measure report 7 Celsius after 10 seconds MTSM 20 Unsolicited temperature measure report 20 Celsius after 15 seconds MTSM 50 Unsolicited temperature measure report 50 Celsius after Nx5 seconds AT MTSM 0 II Set to stop the unsolicited report OK AT MTSM 3 30 10 40 II Set to out off boundary 10 to 40 Celsius unsolicited reports for every 30 seconds H3 Family AT Commands User Manual Page 219 of 375 FIDCCON MTSM 20 MTSM 12 MTSM 47 AT MTSM Unsolicited current report out off the Low boundary Unsolicited r
216. licited Response New SMS STATUS REPORT Indication 0 ee 141 7 1 13 CDS Unsolicited Response New SMS STATUS REPORT Receipt cceceseeeeees 142 7 1 14 CMGL List MESSAGES cc ccccccsesscsseecscsecsecsccsecscssssecsscsessecsessessesscssesecssesecsesacesesaceassecsecaes 144 7 1 15 CMGR Read M SSaGe cccccccccsesscssescessescesesscescsecsscseesececsesecsscsecsecseesecseesecsesecesesecaeseeseeasens 148 7 1 16 CMSS Send Message from Storage ecccccccscssssesesseseesesesseseeseeceecseeecsesessesenseeenseeeeesereaeeeaes 152 7 1 17 CMGW Write Message to MEMO SY cccccccccccessescsscsseseessesecsessccsesscsesecssssecsesscesesecescseesecaes 153 7 1 18 CMGD Delete MeSSage cc ccccccsccscssecscsssesesscssesecseescesesecssesecseeseesssscesesecsecsecsecsecseceeeseeesseeees 156 7 1 19 CGSMS Select Service for MO SMS MeSsage cccccccscesscscsscescsscsecsecsecsecsesecsseseeeaeaee 157 71220 FOMGS Send SMS t NEUWWORK ia jsccaseesdcarnneaieaeneniaeHaudaceshanteiralaeeuiumamreue 158 7 1 21 CSCB Cell Broadcast MeSSaGe S cc cc ccecccsssscescsecscsecsecscssecscsscsecsscsecsecsesecsececssesecseeseeneeaees 160 SACCESS ANG SOC i230 eaa REENE OOA REENEN AE OANE E RENEE ERE 163 8 1 1 A Repeat Last Command n ssseseenesesesosesoessoeseseseseessesenrsesssoesrsestsosesoestosstsonesresssesesrsesorossrsesesess 163 8 1 2 AT Check AT Cert nm creates oda serewenaven dose can ons bso koalas dtoc
217. livered or not 0 no 1 yes 2 nodetect Other values are reserved lt Transfer delay gt Anumeric parameter 0 1 2 that indicates the targeted time between request to transfer an SDU at one SAP to its delivery at the other SAP in milliseconds refer 3GPP TS 24 008 subclause10 5 6 5 lt Traffic handling Anumeric parameter 1 2 3 that specifies the relative importance for priority gt handling of all SDUs belonging to the UMTS bearer compared to the SDUs of other bearers refer 3GPP TS 24 008 subclause 10 5 6 5 lt Source Statistics Supported in R7 P S a numeric parameter that specifies characteristics of Descriptor gt the source of the submitted SDUs for a PDP context This parameter should be provided if the Traffic class is specified as conversational or streaming refer 3GPP TS 24 008 subclause 10 5 6 5 0 Characteristics of SDUs is unknown default value 1 Characteristics of SDUs corresponds to a speech source Other values are reserved lt Signalling Indication gt Supported in R7 PS a numeric parameter used to indicate confirmat content of submitted SDUs for a PDP context This parameter should be provided if the Traffic class is specified as interactive refer 3GPP TS 24 008 subclause 10 5 6 5 0 PDP context is not optimized for confirmat default value 1 PDP context is optimized for confirmat lt PDP_type gt See CGDCONT and CGDSCONT commands If a value is omitted for a particular c
218. lowest gain value not mute The default value is 8 H3 Family AT Commands User Manual Page 254 of 375 FIDCCON 11 2 14 GTCODECN CODEC Chip Selection This command is used for configuring the internal CODEC and external CODEC internal CODEC is built in the chip model is ALC5621 external CODEC supports CS42L73 and ALC5621 the parameters can be saved if power is off and the changes takes effect when it is restarted The default value is 0 Note For H350 the default value is 2 For H350 xxx 10 H380 This command is not supported Command Syntax Response Action Remarks Set GTCODECN OK Set internal external codec lt choice gt or selection CME ERROR lt err gt Read GTCODECN GTCODECN Check the current codec lt CR gt lt LF gt OK Test GTCODECN GTCODECN list of Check the supported parameters supported choice OK range The following table shows the GTCODECN parameters lt Parameter gt Description lt choice gt 0 choose the codec comes with the module model number is ALC5621 1 choose external codec the module number is ALC5621 2 choose external codec the module number is CS42L73 Example AT GTCODECN GTCODECN 0 OK AT GTCODECN 2 OK AT GTCODECN GTCODECN 0 2 OK H3 Family AT Commands User Manual Page 255 of 375 FIDCCON 11 3PCM Command 11 3 1 MADIGITAL Enable Digital Audio or Disable Digital Audio T
219. lowing table shows the FTPSTOR parameters lt Parameter gt Description File name A file name or a file path name string the max length is 255 octets File type File type ASCII or Binary numeric in the range of 0 1 0 ASCII 1 Binary Offset Strat upload offset address range 0 OxFFFFFFFE Example AT FTPSTOR 123 TXT OK FTPSTOR 2 FTPSTOR 1 AT FTPSTOR 123 TXT 0 10 start to resume from the No 10 characters of offset address OK FTPSTOR 2 FTPSTOR 1 store data to file123 TXT 14 17 FTPRETR Retrieve a File This command makes the server send a copy file in the path name to the client It won t affect the file status and contents on the server site Hexadecimal data 03 and 10 will be translated add 10 in the front like server hexadecimal data 03 10 11 10 will be translated to 10 03 11 10 10 Command Syntax Response Action Remarks Set FTPRETR lt file_name gt lt file_type gt lt Offset gt OK FTPRETR lt result gt or ERROR lt error_code gt lt file name gt is a complete qualified path and file name on the server site lt Offset gt is the file offset address already exists on the server this means the server support file transfer resume The command execution result return to the user as an unsolicited response H3 Family AT Commands User Manual Page 361 of 375 FIDCCON 0 operation fails 1
220. lt pid gt and lt dcs gt nor lt length gt lt toda gt or lt tooa gt in CMT CMGL CMGR result codes for SMS DELIVERs and SMS SUBMITs in text mode for SMS COMMANDs in CMGR result code do not show lt pid gt lt mn gt lt da gt lt toda gt lt length gt or lt cdata gt default 1 Means show the values in result codes Example AT CSDH CSDH 0 1 OK AT CSDH CSDH 0 OK AT CMGR 160 SMS SUBMIT CMGR STO UNSENT 0544565034 ABC OK AT CSDH 1 OK AT CMGR 160 CMGR STO UNSENT 0544565034 81 29 0 0 04 11 04 09 48 36 08 97254120032 145 3 ABC OK H3 Family AT Commands User Manual Page 131 of 375 FIDCCON 7 1 7 CNMI New Message Indications to Terminal This command handles enabling of unsolicited notifications to the terminal when an SMS is received by the H3xx After sending an unsolicited response to the TE the H3xx will expect a CNMA new message acknowledgement from the TE within a predefined timeout of 15 seconds Within the timeout the H3xx will not send another unsolicited response to the TE before the previous one is acknowledgement If the H3xx does not receive acknowledgment within the required time CNMI parameters will NOT be reset automatically and the unsolicited response will send to the TE again Command Syntax Response Action ael CNMI lt mode gt lt mt OK gt lt bm gt lt ds gt lt bfr gt or I CMS
221. lue H3xx supports 2 ADC channel converter This command returns the current ADC values for the requested channel The values received from the first converter represent the DC voltage levels of the input pin The returned value is a multiplication of the input level by 1000 e g input level of 0 56V will return 560 Command Syntax Response Action Remarks Execute AT MMAD MMAD lt Converter_number gt lt Convert ed_Value gt OK Or CME ERROR lt err gt Read AT MMAD Same as AT MMAD H3 Family AT Commands User Manual Page 216 of 375 FIDCCON The following table shows the MMAD parameters lt Parameter gt Description lt Converter Number gt 1 2 Select the A2D converter lt Converted Value gt A decimal value represents the returned digital value The input level multiplied by 1000 Example AT MMAD MMAD 1 500 500mV must less than 1000 MMAD 2 375 375mV must less than 1000 OK 10 2 5 MTSM Temperature Sensor Measurement This command measures the current temperature sensor value in Celsius degrees This temperature is taken from a Thermistor internally All the parameters restore to default values when H3xx restart All the parameter default value is 0 Note Incase that AT parameters are set and executed and a reset or a power cycle occurs the H3xx continues with the execution of the AT command using the saved parameters until the user changes
222. ly AT Commands User Manual Page 363 of 375 FIDCCON Test FTPGET FTPGET file name 0 1 0 Ox PERRPEREI Return command format OK The following table shows the FTPGET parameters lt Parameter gt Description lt filename gt A file name or a file path name string the max length is 255 octets lt viewmode gt Download mode 0 text mode 1 binary mode lt offset gt Download offset address range 0 OxFFFFFFFE lt eof gt 0 file downloading 1 All file data have been downloaded Example attftpget 123 txt O download 123 txt OK FTPGET 2 data is downloaded FTPGET 1 download successfully at ftpget 123 txt 0 283800 Idownload 123 txt start to download from offset address 283800 OK FTPGET 2 FTPGET 1 download successfully OK at ftpget 123 txt 0 293800 OK FTPGET 0 download failed the offset may higher then the max length H3 Family AT Commands User Manual Page 364 of 375 FiIDCCON 14 19 FTPRECV Read Data through the Port This command needs to be used with FTPGET command together it can output the data in the buffer from the port different from FTPRETE command it is pure output no escape character So before output the data it will show the length of the output data it the buffer is empty then the data length will show O Note e FTPGET command must be executed before use this command otherwise there is no data out
223. mand Refer to CSCS Select Terminal Character Set If the string begins with an alphanumeric character it may be entered with H3 Family AT Commands User Manual Page 93 of 375 FIDCCON or without quotation marks for example GBP DEM lt ppu gt Price per unit A dot is used as a decimal separator precision of 1 1000 15 digit maximum for example 2 667 See notes below lt passwd gt SIM PIN2 password Maximum string length is 8 characters If this value is exceeded the command terminates in an error If PIN2 is incorrect CME ERROR incorrect password is displayed Example AT CPUC OK AT CPUC GBP 0 125 2222 OK AT CPUC CPUC GBP 0 125 OK Note e f lt ppu gt contains a dot a maximum of three digits may appear after the dot otherwise an error is generated For example if lt ppu gt 0 61 the Read command displays 0 610 lt ppu gt 1 2345 terminates in an error e f lt ppu gt does not contain a dot the number is divided by 1000 For example if lt ppu gt 1 the Read command displays 0 001 e Due to storage constraints the lt ppu gt value is limited to a range of 0 to 4095 Values beyond this range may result in rounding errors For example if lt ppu gt 4095 the Read command displays 4 095 However if lt ppu gt 4096 the Read command displays 4 090 the last digit is replaced by 0 If lt ppu gt 456789 the Read
224. mber 129 Use for local call 145 Use for international access code 128 Unknown 128 is used to represent an email address or a mailing list In this case lt ph_type gt can be used to further differentiate between the two lt text gt Text identifier for a phone book entry according to the character set as specified by command CSCS lt nlength gt The maximum number of digits in the lt number gt H3 Family AT Commands User Manual Page 110 of 375 FIDCCON lt tlength gt The maximum number of characters in the lt text gt entry indicates if the entry is hidden or not only available if a UICC with an active USIM application is present 0 phonebook entry not hidden lt hidden gt 1 phonebook entry hidden string type field of maximum length lt glength gt character set as specified lt group gt by command Select TE Character Set CSCS lt adnumbe gt string type phone number of format lt adtype gt type of address octet in integer format refer TS 24 008 subclause lt adtype gt 10 5 4 7 string type field of maximum length lt slength gt character set as specified lt secondtex gt by command Select TE Character Set CSCS string type field of maximum length lt elength gt character set as specified lt email gt by command Select TE Character Set CSCS lt glength gt integer type value indicating the maximum length of field lt number gt lt alength gt integer type valu
225. meters lt Parameter gt Description lt n gt 0 Disable the result code presentation in the TA 1 Enable the result code presentation in the TA 2 Cancel session not applicable to read command response lt str gt String type USSD string when lt str gt parameter is not given network is not interrogated If lt dcs gt indicates that GSM 03 38 default alphabet is used e If TE character set other than HEX refer command Select TE Character Set CSCS ME TA converts GSM alphabet into current TE character set according to rules of GSM 07 05 Annex A e If TE character set is HEX ME TA converts each 7 bit character of GSM alphabet into two IRA character long hexadecimal number e g character GSM 23 is presented as 17 IRA 49 and 55 If lt dcs gt indicates that 8 bit data coding scheme is used ME TA converts each 8 bit H3 Family AT Commands User Manual Page 100 of 375 FIDCCON octet into two IRA character long hexadecimal number e g octet with integer value 42 is presented to TE as two characters 2A IRA 50 and 65 lt dcs gt GSM 03 38 Cell Broadcast Data Coding Scheme in integer format The supported value are 17 USC2 Language Indicator The first character in a USC2 Lang IND has the language ID in it This situation is not defined by the GSM 7 07 or the 3GPP 27 007 so the assuming that the first character should have the correctly formatted and packed language I
226. mmands User Manual Page 16 of 375 FIDCCON 2 5 Command Syntax Execute command syntax AT XxXxX ATXXX ATXXX Parameter set command syntax AT xxx lt Value gt ATxxx lt Value gt Parameter read Command syntax AT xxx ATXxx Parameter test Command syntax AT xxx ATXXx lt Value gt consists of either a numeric constant or a string constant lt compound_value gt consist of several lt value gt parameters separated by commas Example of compound_value lt value1 gt lt value2 gt lt valueN gt Numeric Constants Numeric constants are expressed in decimal hexadecimal or binary form In the H3xx the definition of each command specifies which form is used for values associated with that command String Constants String constants consist of a sequence of characters bounded at the beginning and end by the double quote character H3 Family AT Commands User Manual FIDCCON 3 Modem ID These commands allow the user to query the type of device that is attached the technology used in the device as well as basic operating information about the H3xx 3 1 CGMI GMI FMI Request Manufacturer ID These commands display manufacturer identification The H3xx outputs a string containing manufacturer identification information Command Response Action AT CGMI CGMI lt manufacturer_ID gt AT CGMI OK AT GMI GMI lt manufacturer_ID gt A
227. mode gt s supported mode values OK H3 Family AT Commands User Manual Page 88 of 375 FIDCCON The following table shows the CAOC parameters lt Parameter gt Description lt mode gt 0 Queries the CCM value 1 Deactivates unsolicited reporting of the CCM value 2 Activates unsolicited reporting of the CCM value Note lt CCM gt String type value representing three bytes of the current call meter value in hexadecimal format for example 00001E indicates decimal value 30 Example Example with prepaid SIM card with 56700 00L prepaid before the test AT OK AT CAOC 2 OK atd 97254565190 OK OK CCCM 000000 CCCM 000006 AT CAOC CAOC 000009 OK CCCM 00000e CCCM 000016 AT CAOC CAOC 00001d OK CCCM 00001e CCCM 000027 AT CAOC 0 CAOC 00002d OK AT CAOC 2 H3 Family AT Commands User Manual Page 89 of 375 FIDCCON CCCM 00003d AT CAOC CAOC 00003f OK CCCM 000046 AT CCCM 00004e CAOC CAOC 00004f OK CCCM 000056 AT CAOC CAOC 00005d OK CCCM 00005e NO CARRIER AT CAOC CAOC 000066 OK 567 prepaid SIM value 102 price per call unit by provider x 66 call units 465 left in prepaid SIM OK There is now 46500 00L prepaid remaining on the SIM card Note The above example shows first time activation of the AOC feature using the H3xx Therefore the accumulated cost is equal to
228. mum SDU size gt lt SDU error ratio gt lt Residual bit error ratio gt lt Delivery of erroneous SDUs gt lt Transfer delay gt lt Traffic handling priority gt lt Source Statistics Descriptor gt lt Signalling Indication gt Read command returns the current settings for each defined context H3 Family AT Commands User Manual Page 286 of 375 FIDCCON Test AT CGEQREQ CGEQREQ lt PDP_type gt list of Test command returns supported lt Traffic class gt s list of values supported as a supported lt Maximum bitrate compound value If the UL gt s list of supported lt Maximum MT supports several bitrate DL gt s list of supported PDP types the lt Guaranteed bitrate UL gt s list of parameter value supported lt Guaranteed bitrate ranges for each PDP DL gt s list of supported lt Delivery type are returned on a order gt s list of supported separate line lt Maximum SDU size gt s list of supported lt SDU error ratio gt s list of supported lt Residual bit error ratio gt s list of supported lt Delivery of erroneous SDUs gt s list of supported lt Transfer delay gt s list of supported lt Traffic handling priority gt s list of supported lt Source statistics descriptor gt s list of supported lt Signalling indication gt s lt CR gt lt LF gt CGEQREQ lt PDP_type gt list of supported lt Traffic class gt s list of supported lt M
229. n 0 Wait FIN ack from Server default 1 Do not wait FIN reponse from server 2 Wait 2MSL lt number_of_acknowledged_bytes gt Total number of bytes that were acknowledged lt close_type gt Connection close type 0 Connection was closed correctly 1 The remote side didn t reply so connection closed by close timeout 2 Other The remote side replied with RST retransmission timeout occurred etc Example H3 Family AT Commands User Manual Page 313 of 375 FIDCCON AT MIPCLOSE MIPCLOSE 1 4 0 2 OK AT MIPCLOSE MIPCLOSE 0 INo opened sockets OK AT MIPCLOSE 1 OK MIPCLOSE 1 0 Socket 1 closed The remote side replies with ACK Need wait few seconds AT MIPCLOSE 1 1 MIPCLOSE 1 2 Socket 1 closed immediately The lt close type gt indicate 2 OK AT MIPCLOSE 3 The terminal closes the opened socket OK MIPCLOSE 3 1024 2 Socket 3 closed Ack indication enabled 1024 bytes were acked AT MIPCLOSE Sockets 1 and 2 are opened MIPCLOSE 1 2 OK 13 4 MIPSETS Set Size and Timeout for Automatic Push This command causes the H3xx to set a watermark in the accumulating buffer and set timeout When the watermark is reached data is pushed from the accumulating buffer into the protocol stack Timeout is used to define interval of time between MIPSEND command and time when data will be automatically pushed from the accumulating buffer into the protocol
230. n CPWD command String type 4 8 character password Shall be the same as password lt passwd gt specified for the facility with command Change Password CPWD lt mode gt 0 Unlock 1 Lock 2 Query status lt passwd gt does not apply Note Query mode return only the active lt fac gt In case no lt fac gt is active the query will return the default 7 lt class gt Sum of integers each representing a class of information Please see class table in CCWA command The default value is 7 lt status gt 0 Inactive 1 Active Example AT CLCK CLCK SC AO Ol OX Al IR AB AG AC FD OK AT CLCK SC 2 CLCK 0 OK AT CLCK SC 1 CME ERROR operation not allowed AT CLCK SC 1 incorrect password CME ERROR incorrect password AT CLCK SC 1 correct password OK From now SIM Card is locked and PIN is requested on power up H3 Family AT Commands User Manual Page 173 of 375 Bs FIBOCOM AT CLCK AB 0 incorrect password CME ERROR incorrect password AT CLCK IR 2 CLCK 0 1 CLCK 0 2 CLCK 0 4 CLCK 0 8 OK AT CLCK IR 1 correct password lt classx gt is defaulted to 7 when not specified OK AT CLCK IR 2 CLCK 1 1 CLCK 1 2 CLCK 1 4 CLCK 0 8 OK AT CLCK 01 1 correct password 3 OK Voice and data international calls barred fax and SMS not barred AT CLCK 01 2 CLCK 1 1 CLCK 1 2 CLCK 0 4 CLCK 0 8 OK H3 Family AT Commands
231. n PIN2 authentication failure i e CME ERROR 17 if PIN2 is not entered right after the failure it is recommended that MT does not block its operation MT is waiting SIM PUK2 to be given this lt code gt is recommended to be returned only when the last executed command resulted in PUK2 authentication failure i e CME ERROR 18 if PUK2 and new PIN2 are not entered right after the failure it is recommended that MT does not block its operation MT is waiting network personalization password to be given MT is waiting network personalization unblocking password to be given MT is waiting network subset personalization password to be given MT is waiting network subset personalization unblocking password to be given MT is waiting service provider personalization password to be given MT is waiting service provider personalization unblocking password to be given MT is waiting corporate personalization password to be given MT is waiting corporate personalization unblocking password to be given SIM PIN AT CPIN lt pin gt SIM PUK AT CPIN lt puk gt lt newpin gt SIM PUK2 AT CPIN lt puk2 gt lt newpin2 gt SIM PIN 2 AT CPIN lt pin2 gt Example H3 Family AT Commands User Manual Page 166 of 375 Bs FIBOCOM AT CPIN OK AT CLCK SC 1 lt correct PIN gt iNot case sensitive OK The facility is enabled by the CLCK command Refer to CLCK Facility Lock AT CPIN CPIN SIM PIN OK
232. n the phone functionality of smart phones and PDAs with phone capabilities in order to prevent interference from a nearby environment This enables other functionality to be used continuosly in environments where phone use is either impractical or not permitted For example on airplanes the use of cellular phones is forbidden during the entire flight but the use of computers is allowed during much of the flight This command enables other functionality to continue while preventing use of phone functionality Command Syntax Response Action Remarks Set CFUN lt fun gt OK The Set command selects the level of CME ERROR functionality lt fun gt in the smart phone Zens or PDA incorporating H3xx Read CFUN CFUN lt power The Read command displays the mode gt current level of functionality lt STK_mode gt OK Test CFUN CFUN list of The Test command displays the list of supported lt fun gt s supported functionality settings OK The following table shows the AT CFUN parameters lt Parameter gt Description lt fun gt Functionality levels SIM APPL from the SIM card SIM APPL from the SIM card 0 Turn off With logging out network 1 Full functionality meaning start up MS from offline mode 4 Disables phone transmit amp receive RF circuits Flight mode 6 Enables the SIM toolkit interface and fetching of proactive commands by 7 Disables the SIM to
233. nal reason 3 indicates UART2 here and only 3 is supported lt data gt 0 F The data should be wrap up with and the valid character is 0 F Example AT UARTSEND 3 30313233 OK HUART2 will output 0123 AT UARTSEND UARTSEND 3 data 10 4 Multiplexer Feature The MUX provides multiple logical communication channels between the DTE and H3xx over one physical RS232 or USB connection This service enables the DTE device to run multiple applications such as GPRS CSD SMS and voice calls while communicating simultaneously with the H3xx The H3xx can support the multiplexing protocol control channel as defined in GSMO07 10 and only basic mode H3 Family AT Commands User Manual Page 228 of 375 FIDCCON 10 4 1 CMUX MUX Startup Command This command is used to start the GSM MUX multiplexing protocol stack When the H3xx received a valid CMUX command it returns OK and changes its state to MUX Init If the parameters are left out the default value is used supported lt mode gt s list of supported lt subset gt s li st of supported lt port_speed gt s list ofsupported lt N1 gt s list of supported lt T1 gt s list ofsupported lt N2 gt s list of supported lt T2 gt s list ofsupported lt T3 gt s list Command Syntax Response Action Remarks Set CMUX lt mode gt lt sub CME ERROR lt err gt The Set command set gt lt requests the
234. name of file to be renamed String max length is 255 octets File name to New name of file to be renamed String max length is 255 octets Example AT FTPREN 1234 txt 12345 txt FTPINFO RNFR 1234 txt OK FTPINFO 350 Ready for RNTO FTPINFO RNTO 12345 txt FTPINFO 250 Rename successful FTPREN 1 14 12 FTPLIST Request List This command makes the server send a list to the client Note If path name specified a directory or other file groups the server will send a list of the files in the specified directory If the path name specified a file then the server should send the current information of this file No parameter means current working directory or default Command Syntax Response Action Remarks Set FTPLIST lt file directory OK FTPLIST lt result gt lt list of directory files gt Parameter consists of the file directory name as well as the file directory path optional The H3 Family AT Commands User Manual Page 355 of 375 FIDCCON name gt FTPLIST lt result gt or command execution result return to ERROR lt error_code gt the user as an unsolicited response 0 operation fails 1 operation success 2 data follows Read FTPLIST ERROR Not supported Test FTPLIST FTPLIST Return command format lt file directory name gt OK The following table shows the FTPLIST
235. nated and answered by the remote side a OK notification is sent to the terminal from the H3xx and it moves to the online Data state For more information about call failure should use the AT CEER command Note If there is an active voice call and the terminal sends another ATD voice call command to the H3xx the active call is put on hold and the new number is called Command Response Action ATD lt number gt VOICE CALL 1st response Voice call place begins OK 2nd response Voice call connected OK DATA 1st response only Data call connected CONNECT When MO call fails 1 Connection Failure NO CARRIER or BUSY or NO ANSWER 2 General Failure ERROR 3 Security reason such as SIM not present OPERATION NOT ALLOWED 4 Unknown reason UNKNOWN CALLING ERROR H3 Family AT Commands User Manual Page 51 of 375 FIDCCON The following table shows the D parameters lt Parameter gt Description lt number gt Valid phone digits are 0123456789 The following characters are ignored AB C D and lt space gt semicolon When given after lt number string gt a voice call is originated to the given address otherwise a data call is originated The control of supplementary services through the Dial command is not supported as these are controlled through the specific supplementary service commands CCFC CLCK and so on Initiating a GPRS connec
236. nd not by the remote side The remote side stays in the Data mode e The behavior of Escape Sequence command is affected by AT amp D setting Please refer to the description of AT amp D 5 1 3 Hanging Up If you are using a communications program use the Hang up or Disconnect AT command in the program to disconnect the call When using computers in the Dumb Terminal mode return to the Command mode by typing the Escape Sequence and then hang up by typing the Hang up command as follows ATH lt Enter gt OK NO CARRIER If the H3xx responds with OK and NO CARRIER the dial connection is closed 5 2 Receiving a Data Call ATA lt Enter gt This command instructs the modem to be the answering modem Either party may be the answering or the originating modem but both parties cannot be the same modem at the same time You hear the modem handshake and see the result code CONNECT OK Note e Outgoing Voice Call during CSD Call when switching to Command mode e If using Dial Command to make Outgoing Voice Call currently active CSD Call is dropped and the new Voice Call is generated H3 Family AT Commands User Manual Page 50 of 375 FHiIDCCON 5 3 Call Control AT Commands 5 3 1 D Dial Command This command places a DATA VOICE call on the current network The default call type is a data call CSD There must be an explicit request in order to make a VOICE call If a DATA call was origi
237. ndex gt is left out lt oper gt is put in the next free location e If only lt format gt is given the format of the lt oper gt in the read command is changed Note2 e User is prevented from editing index No 0 This index is reserved for the HPLMN record and can not be modified e When entering a new item with an lt index gt to a full list the H3xx deletes the last item stores the new item in the requested entry and shifts the rest of the list down e When entering a new item without an lt index gt to a full list the H3xx replaces the last entry with the new item Note3 MT may also update the User controlled PLMN selector with Access Technology list EFPLMNwWAcT automatically when new networks are selected Note4 The Operator controlled PLMN selector with Access Technology EFOPLMNwAcT and HPLMN selector with Access Technology EFHPLMNwWACcT can not be written since the access conditions is Administrative Note5 The command is implemented according to 3GPP TS 27 007 without acceptance in attention the lt GSM_AcT2 gt lt GSM_Compact_AcT2 gt lt UTRAN_AcT2 gt bits since the H3xx device not using this bits to get the best PLMN Example AT CPOL CPOL 001 032 000 002 OK AT CPOL CPOL 000 002 42501 H3 Family AT Commands User Manual Page 188 of 375 FIDCCON AT CPOL 0 OK AT CPOL CPOL 000 000 IL ORANGE OK AT CPOL CPOL 001 032 000 002 OK AT CPOL 1 2 4250
238. ndication of the call list If no calls are received no information response is sent to the terminal If the command succeeds but no calls are available no information response is sent to the terminal The maximum number of simultaneous multiparty calls is 5 1 5 in active group and 1 on hold Command Syntax Response Action Remarks Set AT CLCC OK The Set command lt state gt or enables disables unsolicited indications CME ERROR lt err gt Execute AT CLCC CLCC lt idx gt lt dir gt lt call state gt The Execute command lt mode gt lt mpty gt lt number gt lt type enables the receiving of gt lt CR gt lt LF gt data about current calls CLCC lt idx gt lt dir gt lt call state gt lt mode gt lt mpty gt lt number gt OK Read AT CLCC CLCC lt state gt The Read command 7 OK returns the call status or CME ERROR lt err gt Test AT CLCC CLCC List of supported lt state gt s OK or CME ERROR lt err gt H3 Family AT Commands User Manual Page 83 of 375 FIDCCON The following table shows the CLCC parameters lt Parameter gt Description lt state gt 0 Disable CLCC unsolicited indication 1 Enable CLCC unsolicited indication The default value is 0 lt idx gt Integer type call identification number lt dir gt 0 Mobile originated call MO 1 Mobile terminated call MT lt call state gt The state of the call 0
239. ng command ATD 876 5555 lt Enter gt Note If you receive characters which were sent you can disable this with using the Echo command ATEO lt Enter gt After issuing the Dial command and if the remote modem answers the call the two modems send high pitched carrier tones to one another which establish the transmission speed and other parameters for the data connection This process is called negotiation After the negotiation process the message CONNECT followed by the connection speed is received If the other phone line is busy the message BUSY is received If the other modem does not answer the message NO CARRIER is received Once a connection has been established the modem is ready to immediately begin transmitting and receiving data This may vary from sending messages to each other sending or receiving files logging on to an information service or any other data communication task you wish to perform 5 1 2 Switching From Data Mode to Command Mode To switch the connection from Data mode to Command mode send the Escape Sequence command H3 Family AT Commands User Manual Page 49 of 375 FIDCCON If the modem responds with OK to the Escape command the modem is in Command mode and the dial connection is still active and you can use the AT command set Note e The character in the Escape Sequence pattern can be changed using the S2 S register e Escape is detected only by the H3xx a
240. ng the start of a recording period The duration does not erase the VTD duration Note In GSM the tone duration value can be modified depending on the specific network H3 Family AT Commands User Manual Page 243 of 375 FIDCCON If the active call is dropped in the middle of playing a DTMF tone the following unsolicited message transfers to TE VTS Call termination stopped DTMF tones transmission Command Syntax Response Action Remarks Set VTS lt DTMF OK The Set command sets the tone gt lt duration gt and duration if entered or CME ERROR lt err gt Test VTS VTS list of supported The Test command displays the lt DTMF gt list of supported list of supported DTMF tones lt durations gt s and tone lengths OK The following table shows the VTS parameters lt Parameter gt Description lt DTMF gt String of ASCII characters 0 9 String length is up to 32 characters long lt duration gt A DTMF tone of different duration from that set by the VTD command 1 10 100mS to 1S adjustable Note The duration defined by VTS is specific to the DTMF string in this command only It does not erase the duration defined by the VTD command and is erased when the H3xx is powered down If lt duration gt is not defined the VTD value is used 11 2 9 VTA Set play DTMF type This command enable disable play DTMF tone at local side when s
241. not supported Command Syntax Response Action Remarks Set MCS OK The Set command Enables Disables the T lt n gt or unsolicited call status messages CME ERROR lt err gt Read MCS MCST lt state gt The Read command returns the current T OK call processing state When a change in call state occurs and the MCST is set to n 1 the H3xx will give the following indication MCST lt state gt MCST Parameters The following table shows the MCST parameters lt Parameter gt Description lt n gt 0 Disable MCST unsolicited indication 1 Enable MCST unsolicited indication lt state gt 1 Idle call state 2 Single incoming call 3 Single call active 4 Multi party call active 5 Single call held 6 Multi party call held 7 Dual call fully connected active call and held call 8 Dual multi party call active H3 Family AT Commands User Manual Page 86 of 375 FIDCCON 9 Dual multi party call held 10 Single active call plus call waiting 11 Multi party call active plus call waiting 12 Single call held plus call waiting 13 Multi party call held plus call waiting 14 Dual calls plus call waiting 15 Dual multi party calls active plus call waiting 16 Dual multi party calls held plus call waiting 17 Call control busy 64 Calling 68 No Service 69 No Redial 72 Security Fail Example AT MCST MCST lt i
242. nse lt Destination_IP gt lt t messages will be displayed within unsolicited H3 Family AT Commands User Manual Page 332 of 375 FIDCCON ype gt lt code gt responses along with round trip times lt RTT gt Read MPING MPING The read command displays currently selected lt count gt lt size gt lt TTL parameters values for MPING set command gt lt TOS gt lt TimeOut gt If ping sending procedure is currently in OK process then user selected parameters for AT MPING command will be displayed otherwise default parameter values will be displayed Test MPING MPING The test command displays all supported lt count gt lt size gt lt TTL parameters values for MPING set command gt lt TOS gt lt TimeOut gt OK The following table shows the MPING command parameters lt Parameter gt Description lt mode gt 0 Abort current ping request execution 1 Launch new ping request There is no default value appropriate ERROR will be displayed if parameter is not supplied lt Destination_IP host name gt Specifies the target machine computer which is identified either by IP address 4 octets long in dotted decimal notation or by host name of maximum 255 not including double quotes characters long in dotted notation Each octet of IP address has valid value range of 0 to 255 Host names are not case sensitive and can contain alphabetic or num
243. nt The brackets themselves do not appear in the command line Optional sub parameter of a command or an optional part of terminal information response enclosed in square brackets The brackets themselves do not appear in the command line When the sub parameter is not provided in the parameter ie type commands the new value equals its previous value In action type commands the action should be performed on the basis of the recommended default setting of the sub parameter II Denotes a comment and should not be included in the command 2 4 2 Command Structure Each AT command has the AT or at prefix string except the commands A and Each AT command has the suffix lt CR gt except the commands A and Example AT CSQ lt CR gt ATS24 lt CR gt An AT command line may contain one or more commands Delimiters are used to separate the commands from each other The delimiter is either a semicolon or none meaning space basic commands Example ATS0 1V1Q0E0 lt CR gt AT IFC 0 0 ICF 3 4 CNMI 2 1 0 0 0 lt CR gt 2 4 3 Results Code Structure By default the H3xx responds with verbose response codes The results code prefix is lt CR gt lt LF gt The results code suffix is lt CR gt lt LF gt Example lt CR gt lt LF gt CSQ 99 99 lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt The unsolicited results code is same as the Results code H3 Family AT Co
244. nt Error cccccccceccssssesssseseesesceccsceecseeesesecsenesseseeseeeeseneeseeeeaees 46 4 3 2 CEER Extended Error Report cccccccccccsccsscscesecscssceecsecseesecseesecsesscssesecsseseesesecesesecacseeseeseens 47 9 Call Conto liiin ea a eo aou aba E E a aa EE E Ea r iai 49 5 1 Managing a CSD Data Call iicccteccicssccsccenetineccsscss ccenscsedhssesnebescscesdseslacssecscnssdtvsvs EEEE T 49 5 1 1 Simple Dialing msnen nnani e a e R E S A a On a SN 49 5 1 2 Switching From Data Mode to Command MOde cccccccccccssessescessesesscescsecseesecsesscesesecseeseeseesees 49 51 9 hanging UDaiciso se niesesnieeresaai ae anisar e E E E EAE SE EAE E EOE ORE EEEE E EEE Enis 50 5 2 Receiving a Data Callipso a E R A 50 5 3 Call Control AT COMMaNd Sss cisnienia i a a a aS 51 5 1D Dial Command sisien e E E E E R 51 5 3 2 D gt Direct Dialing from Phone BOoksS cccccccccsecscesesscssesecssescesesscescsecsecsecsecseesecsceeeecseceecseeneeaes 52 5 3 3 DL Dial Last NUM ber s esessessssssssssresisresrsrsssssssesssntestnrsntsrrrrerssreresesstnrentnrantarerrrestertnesstntarenraresret 54 5 34 H ang ups Call reisseri aieas E E NEEE Eaa E AEEA AOE TERRES 55 5 3 5 A Answer Incoming Call nresnain E EEEa dEi 56 5 3 6 CRC Cellular Result Codes and RING CRING Incoming Call Indication 000 0 0 57 5 3 7 CLIP Calling Line Identification cecsceseseeseccsecseeeseseeseeeeseseesesececsecaeseeseseeseeessaneeeeeesesaes 60 9 9 9 CLIP
245. nt was 226 vsFTPd 2 0 5 secure fast stable This command is used for requesting the operating system type of the server Command Syntax Response Action Remarks Set FTPSYST OK FTPSYST lt result gt lt system gt or ERROR lt error_code gt 3 The command execution result return to the user as an unsolicited response 0 operation fails 1 operation success H3 Family AT Commands User Manual Page 358 of 375 FIDCCON 2 data follows Read FTPSYST ERROR Not supported Test FTPSYST ERROR Not supported Example AT FTPSYST OK FTPSYST 2 UNIX Type L8 Version SUNOS FTPSYST 1 14 15 FTPNOOP No Operation This is a no operation command which means it doesn t do anything Note FTPNOOP doesn t affect any parameter or earlier command It doesn t do anything except request the server to send a response Command Syntax Response Action Remarks Set FTPNOOP OK FTPNOOP The command execution result lt result gt or ERROR return to the user as an lt error_code gt unsolicited response 0 operation fails 1 operation success Read FTPNOOP ERROR Not supported Test FTPNOOP ERROR Not supported Example AT FTPNOOP FTPINFO NOOP OK FTPINFO 200 NOOP command successful FTPNOOP 1 H3 Family AT Commands User Manual Page 359 of 375 FiIDCCON 14 16 FTPSTOR Store F
246. o corresponding unsolicited result code shall be issued when the MT returns to a command state lt GCA is a part of the group call reference and indicates group call area lt Gid gt is a part of the group call reference and indicates group call identification The lt ackflag gt 1 proposes that a predefined confirmation procedure is to be used after the call is ended For lt ackflag gt 0 no confirmation procedure is required H3 Family AT Commands User Manual Page 59 of 375 FIDCCON Example AT CRC CRC 0 OK AT CRC CRC 0 1 OK Example RING CRING indication Incoming Data Call RING RING RING AT CRC 1 Enable extended ring format OK CRING REL ASYNC CRING REL ASYNC ath OK AT CRC 1 OK CRING ALT Voice Data NO CARRIER 5 3 7 CLIP Calling Line Identification This command controls the Calling Line Identity CLI presentation indication to the terminal when an incoming call is detected by the H3xx This command allows the user to query the provisioning status of the CLI by the network and by the H3xx The command also allows the user to enable disable the CLI presentation by the H3xx to the terminal The CLIP indication information varies depending on what is provided by the network and what information is stored in the H3xx phone book Command Syntax Response Action Remarks Set AT CLIP OK The Set command enables or disables H3 Family AT
247. o hang up the current call Command Syntax Response Action Remarks Set CHUP OK The Set command hangs up the l current GSM call or CME ERROR lt err gt Example atd15986784172 OK OK H3 Family AT Commands User Manual Page 78 of 375 FIDCCON At CHUP OK NO CARRIER 5 3 17 MDC Selection of Desired Message to Be Displayed Upon Connection of a Voice Call This AT command enables you to select the desired messages to be displayed upon connection of a voice call with a remote party The OK and CONNECT messages are available Note For H350 xxx 10 H380 this command is not supported Command Syntax Response Action Remarks Set MDC lt mod OK The Set command selects which of the e gt a supported messages will be displayed upon connection of a voice call CME ERROR lt mode gt Command Parameters lt err gt 0 Display OK on voice call connection 1 Display CONNECT on voice call connection Default Values Power Up As previously saved in NVM 0 Before Set command is first used Read MDC MDC lt mode gt The Read command should return the OK current selection of lt mode gt Test MDC MDC list of The Test command returns the possible supporten lt mode gt values lt mode gt s OK Example AT MDC MDC 0 1 H3 Family AT Commands User Manual Page 79 of 375 FIDCCON AT MDC 1 OK ATD lt number gt OK CONNECT AT MDC
248. ocal lt destination port range gt context identification lt source port range gt lt ipsec patarei Seas security parameter index spi gt lt type of service tos ipv4 and mask traffic class ipv6 and mask gt lt flow label ipv6 gt TIM Read CGTFT CGTFT lt cid gt lt packet The read command filter identifier gt lt evaluation precedence index gt lt source address and subnet mask gt lt protocol number ipv4 next header ipv6 gt lt destination port range gt lt source port range gt lt ipsec security parameter index spi gt lt type of service tos ipv4 and mask traffic class ipv6 and mask gt lt flow label ipv6 gt returns the current settings for all Packet Filters for each defined context H3 Family AT Commands User Manual Page 301 of 375 FIDCCON lt CR gt lt LF gt CGTFT lt cid gt lt packet filter identifier gt lt evaluation precedence index gt lt source address and subnet mask gt lt protocol number ipv4 next header ipv6 gt lt destination port range gt lt source port range gt lt ipsec security parameter index spi gt lt type of service tos ipv4 and mask traffic class ipv6 and mask gt lt flow label ipv6 gt _ Test CGTFT CGTFT lt PDP_type gt list of supported lt packet filter identifier gt s list of supported lt evaluation precedence index
249. ode the session remains connected 2 Deactivate GPRS and returns to command mode The default value is 2 10 1 7 ICF DTE DCE Character Framing This command determines the local serial port start stop asynchronous character framing used by the DCE when accepting DTE commands and transmitting information text and result codes whenever these are not done automatically Auto detect for framing is not supported Command Syntax Response Action Remarks Set ICF lt format OK The Set command determines the gt lt parity gt CME ERROR lt err gt local serial port start stop character framing Read ICF ICF lt format gt lt parity gt The Read command displays the CME ERROR lt err gt currently selected character framing Test ICF ICF list of supported The Test command displays a list of lt format gt values list of supported lt format gt and lt parity gt H3 Family AT Commands User Manual Page 211 of 375 FIDCCON supported lt parity gt values values CME ERROR lt err gt The following table shows the ICF parameters lt Parameter gt Description lt format gt Determines the number of bits in the data bits the presence or absence of a parity bit and the number of stop bits in the start stop frame 1 8 Data 2 Stop can be set only with lt parity gt 4 2 8 Data 1 Parity 1 Stop can be set with lt parity gt of Oor 1
250. olkit interface and fetching of proactive commands by H3 Family AT Commands User Manual Page 214 of 375 FIDCCON 8 Disable fetching of proactive commands by SIM APPL from the SIM card 15 Hardware reset Need power cycle the module lt power mode gt MS is switched on 2 Invalid mode 4 Flight mode lt STK_mode gt 0 Inactive state 6 Enables the SIM toolkit interface and fetching of proactive commands by SIM APPL from the SIM card 7 Disables the SIM toolkit interface and fetching of proactive commands by SIM APPL from the SIM card 8 Disable fetching of proactive commands by SIM APPL from the SIM card Example AT CFUN CFUN 0 1 4 6 7 8 15 OK AT CFUN CFUN 1 0 OK AT CFUN 4 Disable phone transmit and receive RF circuits OK AT CFUN CFUN 4 Power cycling AT CFUN CFUN 4 0 AT COPS COPS 2 OK H3 Family AT Commands User Manual Page 215 of 375 FIDCCON AT CFUN 1 II Enable phone transmit and receive RF circuits through 1 OK OK AT CFUN CFUN 1 0 OK AT COPS COPS 0 0 CHINA MOBILE OK 10 2 3 CPWROFF Switch off MS This command allows to switches off the H3xx shutdown the system Command Syntax Response Action Remarks Set AT CPWROFF OK Shutdown the system or CME ERROR lt error gt Test AT CPWROFF OK 10 2 4 MMAD Query and Monitor ADC Value This command intends to query and monitor ADC va
251. omain requests CGANS may also be used Incoming circuit switched calls can be neither manually nor automatically answered 3 Modem compatibility mode Packet Domain and circuit switched calls default Automatic acceptance of both Packet Domain network requests and incoming circuit switched calls is controlled by the SO command Manual control uses the A and H commands respectively to accept and reject Packet Domain requests CGANS may also be used Circuit switched calls are handled as described elsewhere in this specification 4 Turn on automatic negative response for Packet Domain only Packet Domain network requests are automatically rejected Example AT CGAUTO 0 OK AT CGAUTO 1 OK AT CGAUTO 4 OK AT CGAUTO 5 ERROR AT CGAUTO CGAUTO 0 4 OK Note When the CGAUTO 1 command is received the MT shall attempt to perform a PS attach if it is not already attached Failure will result in ERROR or if enabled CME ERROR being returned to the TE Subsequently when the MT announces a network request for PDP context activation by issuing the unsolicited result code RING or CRING to the TE this is followed by the intermediate result code H3 Family AT Commands User Manual Page 278 of 375 FIDCCON CONNECT The MT then enters V 250 online data state and follows the same procedure as it would after having received a CGANS 1 with no lt L2P gt or lt cid gt values specified 12 2 11
252. ommand Syntax Response Action Remarks Set 12 lt guard_ OK The Set command sets the CSD time gt CME ERROR escape character guard time value if eens all parameters are valid Read 12 lt guard_time gt The Read command displays the OK current CSD escape character guard time H3 Family AT Commands User Manual Page 32 of 375 FIDCCON The following table shows the S12 parameters lt Parameter gt Description lt guard_time gt CSD escape character guard time units of 50 msec Range is 0 to 255 The default value is 20 4 1 8 amp V View Configuration This command reports the current S registers and the stored user profile Note For H350 xxx 10 H380 this command is not supported Command Syntax Response Action Remarks Execute amp V ACTIVE PROFILE The Execute command displays the current active configuration and stored user profiles profile data STORED PROFILE 0 profile data STORED PROFILE1 profile data OK or CME ERROR lt err gt Example AT amp V ACTIVE PROFILE amp C1 amp D2 amp K3 E1 QO V1 X0 YO S00 000 S02 043 S03 013 S04 010 S05 008 07 030 S12 020 CBST 007 000 001 CRLP 061 061 048 006 CR 000 CRC 000 H3 Family AT Commands User Manual Page 33 of 375 FIDCCON STORED PROFILE 0 amp C1 amp D2 amp K3 E0 QO V1 X0 S00 000 S02 043 S03 013 S04 010 S05 008 07 030 S12 020 CB
253. on 0 Transmit result codes 1 Suppress result codes lt value gt The default value is 0 H3 Family AT Commands User Manual Page 27 of 375 FIDCCON Example ATQO OK ATQ Q 0 OK ATQ4 ERROR ATQ1 No response because result codes are suppressed ATQ4 II No response because result codes are suppressed 4 1 3 E Command Echo This command defines whether input characters are echoed to output If so these characters are echoed at the same rate parity and format at which they were received Note For H350 xxx 10 H380 ATE are not supported Command Syntax Response Action Remarks Set ATE lt value gt OK The Set command sets whether or not to echo characters or CME ERROR lt err gt Read ATE lt value gt The Test command for E is not defined OK by ITU and therefore is not supported by the H3xx The H3xx returns an error The following table shows the E parameters lt Parameter gt Description lt value gt 000 Does not echo characters 001 Echoes characters The default value is 001 Example H3 Family AT Commands User Manual Page 28 of 375 FIDCCON ATE 001 OK 4 1 4 X Result Code Selection and Call Progress Monitoring Control This command defines the CONNECT result code format It determines whether or not the H3xx transmits particular result codes to the user It also controls whether the H3xx verifies
254. onditions are met If the H3xx does not receive acknowledgment after receiver a SMS within the required time CNMI parameters will NOT be reset automatically and the CMT or CDS unsolicited response will send to the TE again Command Syntax Response Action Remarks Set AT CNMA OK For text mode CMGF 1 or CMS ERROR lt err gt Set AT CNMA lt n gt OK For PDU mode CMGF 0 Sone ear or Note All parameters lt n gt lt length gt and DU lt ctrl Z ESC gt PDU are optional CMS ERROR lt err gt Read The Read command for CNMA is not defined by ETSI and therefore is not supported by the H3xx The H3xx returns an error Test AT CNMA OK CNMA list of supported lt n gt s in PDU mode H3 Family AT Commands User Manual Page 136 of 375 FIDCCON The following table shows the CNMA parameters lt Parameter gt Description lt n gt 0 command operates similarly as defined for the text mode 1 send RP ACK 2 send RP ERROR lt length gt Length of the PDU in PDU mode Example AT CNMI 2 2 OK AT CMSS 142 054565132 send to myself CMSS 74 OK CMT 97254565132 03 04 09 17 14 33 08 new message text AT CNMA OK AT CNMI CNMI 2 2 0 0 OK AT CNMI 1 0 0 1 OK AT CSMP 49 167 OK AT CSMP CSMP 49 167 0 0 OK AT CNMI CNMI 1 0 0 1 0 OK AT CMSS 295 CMSS 184 OK CDS 6 184 972524680592 145 05 08 02 17 19 23 08 05 08 02 17
255. one play ccc cccccsccscesscecesceecsscsecsecseseesessessesecseeseeeeeees 250 11 2 13 MMICG Microphone Gain Value cc cccccesessecssssesseeseseeseseeceeesecsesecsesecsensesesseseeeeseeeaeeeees 254 11 2 14 GTCODECN CODEC Chip Selection ccc ccccccesccsesscesesecssesecseeseesesecesssecsecsecsecseeas 255 11 3 IPM COmMminmaine scssi e erre e e cdacdds Sleatidesd Ga deaoendata E R REER 256 11 3 1 MADIGITAL Enable Digital Audio or Disable Digital AUGIO 0 cee ceeteeeeteeseeeeeeeeeeesees 256 11 3 2 MAI2SY Set Digital Audio to Transmit Parameters ccccccccessescsseseseeseteeseteeseseteeneneeees 257 AZ GPRS crient e E E E a E EE EE 260 12 1 GPRS Functionality ii isc tiiecetekien heii ete eels pe ie Rae ia ede ee 260 12 2 GPRS Commands ics oeeie desetessptasaaded Ee eaei Aeae oae Tare EE TE EE eaaa 260 12 2 1 CGCLASS GPRS Mobile Station Class cc eeeescessseseseseeeeeeeeseneeeeseseseseeeeseeeaeeeeeseseseeees 261 12 2 2 CGDCONT Define PDP Context ccc cccccseesessesesenseseeeesesseseeesesessesecsesessenenseeenseeeeeeereaseres 262 12 2 3 CGQMIN Quality of Service Profile Min Acceptable cccccccececsccesecsseseeseeeeeseseeees 265 12 2 4 CGQREQ Quality of Service Profile Requested ccc ceccccccscceeseeneeseeseeseesesecseeseeneeeees 267 12 2 5 CGATT GPRS Attach or Detach enn cecccccsessssesseceseeseseeseseeeseecseecsesecsesanseeseseeeeeeeeseeeeseats 269 12 2 6 D 99 Request GPRS Service Do oo cccccec
256. ons The default value at power up is 17 Message type is SMS SUBMIT and relative VP format lt vp gt Validity Period depending on SMS SUBMIT lt fo gt TP Validity Period Format bits setting If there is no correlation between the VPF and the VP value an error message will be returned Either in integer format see Table or in time string format yy MM dd hh mm ss zz If in integer format the vp will write to SIM EF and read form H3 Family AT Commands User Manual Page 128 of 375 FIDCCON SIM EF when use it lt pid gt Protocol ldentifier The one octet information element by which the SM TL either refers to the higher layer protocol being used or indicates interworking with a certain type of telematic device 0 no interworking SME to SME protocol default Any value between 0 255 will be accepted The SC may reject messages with a TP Protocol ldentifier containing a reserved value or one which is not supported lt dcs gt One octet of Data Coding Scheme indicates the data coding scheme of the DATA and may indicate a message class Note For DCS expanded information see section DCS handling default alphabet 00xx00xx 111 100xx 1 101xxxx 8 bit data 00xx01xx 111101xx UCS2 00xx10xx 1110xxxx reserved 00xx11xx 0100xxxx 1011xxxx The default value at power up is 0 Default alphabet The following table shows the VP format
257. or_code gt path The command execution result return to the user as an unsolicited response 0 operation fails 1 operation success Read FTPRMD ERROR Not supported Test FTPRMD FTPRMD Returns command format lt directory name gt OK The following table shows the FTPRMD parameter lt Parameter gt Description Directory name The name of file directory need to be removed string the max length is 255 octets Example AT FTPRMD 1234 FTPINFO RMD 1234 OK FTPINFO 250 RMD command successful FTPRMD 1 H3 Family AT Commands User Manual Page 351 of 375 FIDCCON 14 8 FTPPWD Print Working Directory This command is used for requesting the server to return name of current working directory Command Syntax Response Action Remarks Set FTPPWD OK FTPPWD lt directory_name gt indicates the current lt result gt lt directory_ working directory The command name gt or ERROR execution result return to the user as an lt error_code gt unsolicited response 0 operation fails 1 operation success 2 String follows is the current working directory Read FTPPWD ERROR Not supported Test FTPPWD ERROR Not supported Example AT FTPPWD FTPINFO PWD OK FTPINFO 257 export home test is current directory FTPPWD 2 export home test is current directory FTPPWD 1 14 9 FTPCDUP Change Directory up
258. ormation about the number of entries and the maximum size of a phone number and alpha tag fields in the phone book This command acts on the currently active phone book as selected with the CPBS command lt CR gt lt LF gt CPBR lt index2 gt lt number gt lt type gt lt text gt lt hidden gt lt group gt lt adnumber gt Command Syntax Response Action Remarks Set CPBR CPBR The Set command lt index lt index1 gt lt number gt lt type gt lt text gt returns phone book 1 gt lt ind lt hidden gt lt group gt lt adnumber gt entries ex2 gt lt adtype gt lt secondtext gt lt email gt H3 Family AT Commands User Manual Page 109 of 375 FIDCCON lt adtype gt lt secondtext gt lt email gt I OK or CME ERROR lt err gt Test CPBR CPBR list of The Test command supported lt index gt s lt nlength gt returns the entry range lt tlength gt lt glength gt supported by the current lt alength gt lt slength gt lt elength gt Storage as 4 compound value and the maximum OK lengths of the lt number gt and lt text gt fields The following table shows the CPBR parameters lt Parameter gt Description lt index1 gt Index for a given phone book entry lt index2 gt lt number gt Phone number of a given entry lt type gt The address type of a phone nu
259. ot implemented 1100 Conditional IE error 1101 Message not compatible with protocol state 1102 Recovery on timer expiry 1111 Protocol error unspecified 1127 Interworking unspecified 1279 Number not allowed 1283 CCBS possible 15 2 CMS Error Parameter Description lt Err gt 1 Unassigned unallocated number 8 Operator determined barring 10 Call barred 17 Network failure 21 Short message transfer rejected 22 Memory capacity exceeded 27 Destination out of service 28 Unidentified subscriber 29 Facility rejected 30 Unknown Subscriber 38 Network out of order H3 Family AT Commands User Manual Page 370 of 375 FIDCCON 41 Temporary failure 42 Congestion 47 Resources unvailable unspecified 50 Requested facility not subscribed 69 Requested facility not implemented 81 Invalid short message reference value 95 Invalid message unspecified 96 Invalid mandatory information 97 Message type non existent or not implemented 98 Message not compatible with short message protocol state 99 Information element non existent or not implemented 111 Protocol error unspecified 127 Interworking unspecified 128 Telematic interworking not supported 129 Short message type 0 not supported 130 Cannot replace short message 143 Unspecified TP PID error 144 Data coding scheme alphabet not su
260. out incode The MIPSEND data buffer range is lt Socket_ID gt lt Status gt lt FreeSize 0 lt buffer lt 2048 bytes j After timeout the data will be push or automatic and returns to regular AT ERROR command mode The default timeout is 12s Notes If there is any data in the buffer sent by previous mipsend H3xx will reply ERROR to TE Example Opening socket 2 already AT MIPSEND 2 gt This is the data in HEX lt timeout gt OK MIPPUSH 2 0 H3 Family AT Commands User Manual Page 320 of 375 FIDCCON MIPSEND 2 0 2048 OK Send data at fixed length All characters can be send at this method Command Syntax Response Action Remarks Set MIPSEND MIPPUSH After command received H3xx will respond lt Socket_l lt Socket_ID gt lt Status gt lt pu gt lt CR gt lt LF gt Daspal shga data lengh Send any data in HEX The data buffer ane MIPSEND range is 0 lt data_len lt 2048 bytes Sper Er Seas When H3xx receive the corresponding SERIES length data the data will be push automatic or and returns to regular AT command mode ERROR Notes The redundant data will be lost Notes If there is any data in the buffer sent by previous mipsend H3xx will reply ERROR to TE Example Opening socket 2 already AT MIPSEND 2 10 gt 0123456789abc abc lost OK MIPPUSH 2 0 MIPSEND 2 0 2048 OK H3 Family AT Commands User Manual Page
261. pages lt data gt Message contents in text mode lt length gt Size of message in PDU mode format in octets lt pdu gt Message header and contents in PDU mode format See description in CMGR Read Message 7 1 12 CDSI Unsolicited Response New SMS STATUS REPORT Indication The CDSI unsolicited response is sent to the TE upon receipt of a new SMS STATUS REPORT SMS if the CNMI parameter lt ds gt is set to 2 This unsolicited message indicates that anew SMS STATUS REPORT message was received and is stored in location lt index gt Unsolicited Response CDSI lt mem gt lt index gt The following table shows the CDSI parameters lt Parameter gt Description lt mem gt Message memory space SR status report storage lt index gt Location of the new message Example H3 Family AT Commands User Manual Page 141 of 375 FIDCCON AT CMGF 1 OK AT CSMP 49 165 Set Message type to Status Report see CMGW OK AT CSMP CSMP 49 167 0 0 OK AT CNMI 1 0 0 2 OK AT CMGS 052468000 gt Hello CMGS 188 OK CDSI SR 1 7 1 13 CDS Unsolicited Response New SMS STATUS REPORT Receipt The CDS unsolicited response is sent to the TE upon receipt of a new mobile terminated SMS if the CNMI parameter lt ds gt is set to 1 This unsolicited message displays the received SMS DELIVER message Unsolicited Response In text mode CMGF 1 C
262. pecified GPRS mobile class If the requested class is not supported an ERROR or CME ERROR response is returned Extended error responses are enabled by the CMEE command Command Syntax Response Action Remarks Set AT OK Set command is used to set the CGCLASS lt cl or MT to operate according the ass gt specified mode of operation CME ERROR lt err gt Read AT CGCLASS CGCLASS lt class gt The Read command returns the OK current GPRS mobile class Test AT CGCLASS list of The Test command is used for CGCLASS supported lt class gt s requesting information on the OK supported GPRS mobile classes Note Issuing GPRS actions over a poor quality connection may cause protocol errors and harm data validity To prevent these problems H3xx is equipped with a protection mechanism that confirms GPRS signal strength before issuing GPRS network related commands The following table shows the CGCLASS parameters lt Parameter gt Description lt class gt String parameter that indicates the GPRS mobile class A class A only supported if UMTS SUPPORT is enabled B meaning mobile class B CC class C in GPRS mode CG class C in circuit switched mode Example AT CGCLASS CGCLASS A B CC CG H3 Family AT Commands User Manual Page 261 of 375 FIDCCON Note If a SIM card without GPRS allowance is used AT CGCLASS CGCLASS CC 12 2 2
263. pported 145 Message class not supported 159 Unspecified TP DCS error 160 Command cannot be actioned 161 Command unsupported 175 Unspecified TP Command error 176 TPDU not supported 192 SC busy 193 No SC subscription 194 SC system failure 195 Invalid SME address 196 Destination SME barred 197 SM Rejected Duplicate SM 198 TP VPF not supported 199 TP VP not supported 208 SIM SMS storage full 209 No SMS storage capability in SIM H3 Family AT Commands User Manual Page 371 of 375 FIDCCON 210 211 212 213 224 254 255 300 301 302 303 304 305 310 311 312 313 314 315 317 318 319 320 321 322 330 331 332 340 512 513 Error in MS Memory Capacity Exceeded SIM Application Toolkit Busy SIM data download error TP_FCS_APPL_ERR_START TP_FCS_APPL_ERR_STOP TP_FCS_UNSPECIFIED ME failure SMS service of ME reserved operation not allowed operation not supported Invalid PDU mode param invalid text mode parameter SIM not inserted SIM PIN required PH SIM PIN necessary SIM failure SIM busy SIM wrong SIM PIN2 required SIM PUK2 required incorrect PUK1 memory failure invalid memory index memory full SMSC address unknown no network service network timeout no CNMA acknowledgement expected MN_SMS_RP_ACK MN_SMS_TIMER_EXPIRED 5
264. put e The data in cache will be cleared if use FTPGET command again So before you use FTPGET again please make sure the data in the buffer are fetched to avoid losing data e The data in thebuffer will be cleared when FTP is closed e FTP connection will be closed automatically and buffer will be closed if the data cannot be fetched in 2 minutes Command Syntax Response Action Remarks Set FTPREC FTPRECV V lt LENG LENGTH Shows the actual data length by serial TR DATA port after enter the output data stores in OK the buffer after the data output completed f shows OK or ERROR Read AT FTPR FTPRECV Read the data length stored in current ECV lt available gt buffer OK Test AT FTPR FTPRECV Test the format of this command ECV 1 3000 LENGTH H3 Family AT Commands User Manual Page 365 of 375 FIDCCON The following table shows the FTPRECV parameters lt Parameter gt Description lt available gt Length of the data stored in current buffer range 0 30720 lt LENGTH gt Length of the data need to be output range 1 3000 Example attftpget 123 txt 0 download 123 txt OK FTPGET 2 at ftprecv 30 read 30 bytes FTPRECV 30 e U8 OK FTPGET 1 nvm_dynamic adr_nvm_d GET file downloading completed at ftpget 123 txt 0 283800 start to download from offset address 283800 OK at ftprecv 300
265. r gt Description Socket_ID 1 2 3 4 Number of valid sockets Example AT MIPFLUSH 2 MIPFLUSH 2 OK AT MIPFLUSH 5 ERROR AT MIPFLUSH MIPFLUSH 1 2 Socket number 2 was previously opened using the MIPOPEN command OK 13 10 MIPRUDP Receive Data from UDP Protocol Stack This unsolicited event is sent by the H3xx to the terminal when data is received from the UDP protocol stack Set Command Event MIPRUDP lt Source_IP gt lt Source_Port gt lt socket_ID gt lt Left or SDL gt lt Data gt The following table hows the MIPRUDP parameters lt Parameter gt Description Source_IP IP of the source Source_Port Port of the source Socket_ID 1 2 3 4 Number of valid sockets Left Size of received Data still left in protocol stack SDL Subsequent data length Data Data string received with 0 F hexadecimal digits String ends with a lt CR gt H3 Family AT Commands User Manual Page 326 of 375 FIDCCON Note This unsolicited event will change the destination IP and destination port it means that when a MIPRUDP unsolicited event coming if you do not specify IP and port using MIPPUSH data left in the buffer will be sent to this new destination by default If IPRFMT parameter has been set by AT GTSET the receives data will be reponse at different format 13 11 MIPRTCP Receive Data from TCP Protocol Stack This unsolicited event is sent by the H3xx to the
266. racter set as specified by command Select TE Character Set CSCS lt glength gt integer type value indicating the maximum length of field lt number gt H3 Family AT Commands User Manual Page 113 of 375 FIDCCON lt alength gt integer type value indicating the maximum length of field lt adnumber gt lt slength gt integer type value indicating the maximum length of field lt secondtext gt lt elength gt integer type value indicating the maximum length of field lt email gt Example AT CPBS SM _ Selecting phone book OK AT CPBF Lin CPBF 1 18888888 129 Linzhao OK AT CPBF Voice Searching for string Voice and finding Voice Mail CPBF 2 8613800138000 145 Voicemail OK AT CPBF Searching for everything in phone book and finding all entries CPBF 1 18888888 129 Linzhao CPBF 2 8613800138000 145 Voicemail CPBF 3 18888888 129 abc OK 6 1 4 CPBW Write Phone Book Entry This command enables the user to store a new entry in the phone book or edit delete an existing entry from the phone book A particular entry in the phone book can be stored or the next available entry is used This command writes the entry in the currently active phone book selected with the CPBS command Refer to CPBS Select Phone Book Memory The entry is selected by lt index gt the phone number is entered into the lt number gt field and text associated with
267. received by the H3xx CCWA 358317654321 145 1 Bob AT CHLD 0 Release the waiting call OK NO CARRIER AT CRC 1 IRING indication is not relevant to CCWA indication OK waiting call caller restricted to its CLI presentation used AT CLIR CCWA 128 1 1 ICLI is restricted but call type recognized as voice 5 3 11 CHLD Call Related Supplementary Services Command This command controls the Call Hold and Multiparty Conversation services This command manipulates voice calls only The Set command allows the control of the following call related services Call HOLD A call can be temporarily disconnected from the H3xx but the connection is retained by the network H3 Family AT Commands User Manual Page 66 of 375 FIDCCON MITPY Multi party Conversation Conference calls The network does not reserve more than one traffic channel for a mobile station therefore the H3xx can have only one call on hold at a time Note Only voice calls can be put on HOLD A precondition for the multi party service is that the H3xx is in control of one active call and one call on hold In this situation the H3xx can request the network to begin the MTPY Multi Party service Once a MTPY call is active remote parties may be added disconnected or separated removed from the MTPY call but remain connected to the served mobile subscriber The maximum number of remote parties is 5 In this command the term CAL
268. referred Example AT CBST CBST 0 4 7 12 14 17 68 70 71 75 79 84 115 116 120 121 130 134 0 1 4 5 0 3 OK AT CBST CBST 7 0 1 OK AT CBST 6 OK AT CBST CBST 6 0 1 OK 5 3 15 O Return to Online Data State This command returns the H3xx from the Command mode to the Online Data mode and issues a CONNECT or CONNECT lt text gt result code After dialing or answering atd ata commands and connect the phone enters the Online Data mode where it is able to transfer data but not to enter AT commands H3 Family AT Commands User Manual Page 77 of 375 FIDCCON The ESC command transfers the phone to the Command mode able to input AT commands while preserving the Data call The O command returns the phone to the fully Online Data mode as it was before using the ESC commana Note The escape character t can be changed using the S2 register The time delay between consecutive escape characters is configured using the S 12 register Command Syntax Response Action Execute ATO CONNECT CME ERROR lt err gt If phone is not in Data Call NO CARRIER If connection is not successfully resumed Example ATD035684072 Calling a remote modem data call CONNECT H3xx is in Data mode Escaping back to Command mode using the sequence OK AT H3xx is in Command mode OK ATO Returning to Data mode CONNECT 5 3 16 CHUP Hang Up Call This command causes the H3xx t
269. rer shall provide in sequence SDU delivery or not 0 no 1 yes Other values are reserved lt Maximum SDU size gt Anumeric parameter that 1 2 3 indicates the maximum allowed SDU size in octets refer TS 24 008 subclause 10 5 6 5 lt SDU error ratio gt a string parameter that indicates the target value for the fraction of SDUs lost or detected as erroneous SDU error ratio is defined only for conforming traffic The value is specified as mEe As an example a target SDU error ratio of 5 10 3 would be specified as 5E3 e g CGEQNEG 5E3 refer TS 24 008 subclause 10 5 6 5 lt Residual bit error ratio gt A string parameter that indicates the target value for the undetected bit error ratio in the delivered SDUs If no error detection is requested Residual bit error ratio indicates the bit error ratio in the delivered SDUs The value is specified as mEe As an example a target residual bit error ratio of 5 10 3 would be specified as 5E3 e g CGEQNEG 5E3 refer TS 24 008 subclause 10 5 6 5 lt Delivery of A numeric parameter that indicates whether SDUs detected as erroneous shall H3 Family AT Commands Us er Manual Page 293 of 375 FIDCCON erroneous SDUs gt be delivered or not 0 no 1 yes 2 no detect Other values are reserved lt Transfer delay gt A numeric parameter 0 1 2 that indicates the targ
270. rial number identification IMEI International Mobile Equipment Identification It can be used even when the SIM card is not inserted Command Response Action AT CGSN CGSN lt imei gt AT CGSN OK AT GSN GSN lt imei gt AT GSN OK The following table shows the CGSN GSN parameters lt Parameter gt Description lt imei gt The IMEI International Mobile Station Equipment Identity number is composed of 15 digits as specified by 3GPP TS 23 003 IMEI numbers are composed of the following elements all in decimal digits Type Approval Code TAC 8 digits Serial Number SNR 6 digits Spare digit 1 digit The TAC and SNR are protected against unauthorized changes Example AT CGSN CGSN 004400013805666 OK H3 Family AT Commands User Manual Page 20 of 375 FiIDCCON 3 5 CSCS Select Terminal Character Set This command selects the H3xx character set The H3xx supports the following character sets IRA GSM UCS2 HEX The default value is IRA Command Syntax Response Action OK Set CSCS lt chset gt or CMS ERROR lt err gt CSCS lt selected character set gt OK Read CSCS CSCS lt supported character sets gt OK Test CSCS The following table shows the CSCS parameter optional values lt chset gt Character Set IRA International Reference Alphabet ITU T T 50 GSM GSM default alpha
271. ric lt oper gt short alphanumeric lt op er gt numeric lt oper gt list of supported lt mode gt s list of supported lt format gt s OK each representing an operator present in the network A quadruplet consists of an integer indicating the availability of the operator lt stat gt long and short alphanumeric format of the name of the operator and numeric format representation of the operator If any of the formats are unavailable there is an empty field The list of operators is in the following order home network networks referenced in SIM or active application in the UICC GSM or USIM in the following order HPLMN selector User controlled PLMN selector Operator controlled PLMN selector and PLMN selector in the SIM or GSM application and other networks After the operator list the H3xx returns lists of the supported lt mode gt s and lt format gt s These lists are separated from the operator list by two commas The following table shows the COPS parameters lt Parameter gt Description lt mode gt use automatic mode H3 Family AT Commands User Manual The default value is 0 Determines whether what is displayed is defined by lt oper gt or is done automatically by the H3xx 0 Automatic lt oper gt field is ignored 1 Manual lt oper gt field is present 2 De register from network 3 Set only lt format gt lt oper gt field is ignored us
272. ription 1 Voice telephony 2 data refers to all bearer services with lt mode gt 2 this may refer only to some bearer service if TA does not support values 16 32 64 and 128 4 Fax facsimile services 8 short message service 16 data circuit sync 32 data circuit async 64 dedicated packet access 128 dedicated PAD access 5 3 10 CCWA Indication When a call waiting indication is enabled by the H3xx lt n gt 1 the following unsolicited indication is sent to the terminal from the H3xx CCWA lt number gt lt type gt lt class gt lt alpha gt lt CLI validity gt The following table shows the CCWA parameters lt Parameter gt Description lt n gt Enables disables the call waiting indication to the terminal by the H3xx 0 Disable 1 Enable The default value is 0 lt mode gt Call waiting service request to the network When the lt mode gt parameter is not given the network is not interrogated 0 Disable H3 Family AT Commands User Manual Page 64 of 375 FIDCCON 1 Enable 2 Query status lt class gt Sum of integers each representing a class of information Please see class table in CCWA command The default value is 7 lt number gt Calling line number The number format is specified by lt type gt lt type gt Type of address octet in integer format 145 Default when the dialing string includes the internat
273. rmined barring Normal call clearing User busy No user responding User alerting no answer Call rejected Number changed Non selected user clearing Destination out of order Invalid number format incomplete number Facility rejected Response to STATUS ENQUIRY Normal unspecified No circuit channel available Network out of order Temporary failure Switching equipment congestion Access information discarded requested circuit channel not available Resources unavailable unspecified Quality of service unavailable Requested facility not subscribed Incoming calls barred within the CUG Bearer capability not authorized Bearer capability not presently available Service or option not available unspecified Bearer service not implemented ACM equal to or greater than ACMmax Requested facility not implemented H3 Family AT Commands User Manual Page 369 of 375 FIDCCON 1070 Only restr digital information bearer capability 1079 Service or option not implemented unspecified 1081 Invalid transaction identifier value 1087 User not member of CUG 1088 Incompatible destination 1091 Invalid transit network selection 1095 Semantically incorrect message 1096 Invalid mandatory information 1097 Message type non existent or not implemented 1098 Message type not compatible with protocol state 1099 Information element non existent or n
274. ruction code given in the command Ox6E OxXX wrong instruction class given in the command Ox6F OxXX technical problem with no diagnostic given Response of a successful completion of the command previously issued hexadecimal character uppercase format STATUS and GET RESPONSE return data which gives information about the current elementary data lt response gt file_id This information includes the type of file and its size refer to GSM 11 11 After READ BINARY or READ RECORD command the requested data will be returned lt response gt is not returned after a successful UPDATE BINARY or UPDATE RECORD command Example AT CRSM 1 76 28478 0 0 20 CRSM 145 165 FF OK AT CRSM 192 12258 CRSM 144 0 62168202412183022FE28A01058B032F06038002000A8800 OK AT CRSM CRSM 176 178 192 214 220 242 12037 28599 0 255 0 255 0 255 OK 4 1 14 GTUSIM Checks for USIM Card This command is used to check whether the current SIM is a 2G or 3G sim Note For H350 xx 10 H380 this command is not supported Command Syntax Response Action Remarks Execute Read AT GTUSIM GTUSIM lt state gt State 0 2G SIM AT GTUSIM OK State 1 3G SIM H3 Family AT Commands User Manual Page 42 of 375 FIDCCON 4 1 15 CCID This command returns the card identification number in SIM SIM file EFICCID see GSM 11 11 Chap 10 1 1 as string type Command Syntax Response A
275. s list of supported lt T1 gt s list of supported lt N2 gt s OK The following table shows the CRLP parameters lt Parameter gt Description lt iws gt IWF to MS window size 10 61 The default value is 61 H3 Family AT Commands User Manual Page 176 of 375 FIDCCON lt mws gt MS to IWF window size 10 61 The default value is 61 lt T1 gt Acknowledgement timer T1 39 255 The default value is 48 lt N2 gt Retransmission attempts N2 in integer format refer to GSM 04 22 subclause5 4 3 The default value is 6 Example AT CRLP CRLP 10 61 10 61 39 255 1 255 OK AT CRLP CRLP 61 61 48 6 OK 9 1 3 CREG Network Registration Status This command is used to read current Network registration status and serving cell information Command Syntax Response Action Remarks oa Anes jj 1 The Set command controls the mha or presentation of an unsolicited result code CME ERROR lt err and the result of the Read operation Read AT CREG CREG The Read command returns the status of lt n gt lt stat gt lt lac gt lt ci the result code presentation whether the gt lt AcT gt network has indicated the registration of OK H3xx Location information elements lt lac gt and lt ci gt are returned only when lt n gt 2 and the H3xx is registered in the network H3 Family AT Commands User Manual Pag
276. s All the facility messages except for SC and P2 are sent to the network The facilities are not case sensitive Please see lt fac gt Table lt oldpwd gt String type 4 8 character old password specified for the facility from the H3xx user interface H3 Family AT Commands User Manual Page 170 of 375 Bs FIBOCOM lt newpwd gt String type 4 8 character new password specified by the user lt pwd length gt Maximum length of the facmility password Integer type Example AT CPWD CPWD SC 8 AO 8 Ol 8 OX 8 Al 8 IR 8 AB 8 AG 8 AC 8 P2 8 OK AT CPWD CME ERROR operation not supported AT CLCK sc 1 current pin password OK AT CPWD sc incorrect old password new password CME ERROR incorrect password AT CLCK sc 2 CLCK 0 OK AT CPWD sc old password new password CME ERROR operation not allowed AT CLCK fd 1 current pin2 password AT CPWD p2 old password new password OK AT CLCK ai 2 CLCK 0 1 CLCK 0 2 CLCK 0 4 OK AT CLCK ai 1 correct password OK AT CLCK ai 2 CLCK 1 1 CLCK 1 2 CLCK 1 4 OK AT CPWD ai old password new password OK H3 Family AT Commands User Manual Page 171 of 375 Bs FIBOCOM 8 1 6 CLCK Facility Lock This command locks unlocks or interrogates a H3xx or a network facility lt fac gt any kind of call barring program A password is mandatory for perform
277. s Click on Web_User_Click_Here html FTPINFO 220 FTPINFO 220 FTP client users To connect use anonymous as the login FTPINFO 220 and use your e mail address as the password For example FTPINFO 220 login anonymous FTPINFO 220 password ftpuser adobe com FTPINFO 220 FTPINFO 220 FTPINFO 220 FTPINFO USER anonymous send username FTPINFO 331 Please specify the password please enter the password FTPINFO PASS ftpuser adobe com send password FTPINFO 230 Login successful FTPOPEN 1 H3 Family AT Commands User Manual Page 348 of 375 FIDCCON 14 5 FTPCWD Change Working Directory This command is used for changing the server s current working directory Command Syntax Response Action Remarks Set FTPCWD lt dir OK FTPCWD lt directory_name gt parameter consists of ectory_n ame gt lt result gt Or ERROR the directory name as well as the directory lt error_code gt path optional The command execution result return to the user as an unsolicited response 0 operation fails 1 operation success Read FTPCWD ERROR Not supported Test FTPCWD FTPCWD Returns command format lt directory name gt OK The following table shows the FTPCWD parameter lt Parameter gt Description Directory name Opend file directory or file name String max length is 255 octets Example AT FTPcwd Acrobat OK FTPCWD 1 H3
278. s ATIO Built Mar 23 2012 08 50 27 ATIO Build time Built Mar 23 2012 08 50 27 ATI1 Reserve Reserve Note For H350 xxx 00 it ATI2 Reserve Reserve displays BOOT version BOOT_00 07 ATI3 Product description Fibocom HSPA Module ATI4 Reserve Reserve ATI5 Platform XMM6260 ATIG Reserve Reserve ATI7 Product description H330S HSPA Module ATI8 Software version H330S_V1H 00 09 ATI9 Reserve H330S_V1 1 0 6250 H3 Family AT Commands User Manual Page 23 of 375 FIDCCON 3 9 CNUM Request MSISDN s This command displays up to 2 strings of text information that identify the H3xx The output string contains double quotes On SIM cards that have EFmsisdn file the string s returned are the MSISDN numbers and their associated data On SIM cards that don t have EFmsisdn file the strings returned are the MSISDN numbers and their associated data stored in H3xx NVM Note For H350 xxx 10 H380 CNUM are not supported MSISDN supported Command Response Action CNUM CNUM CNUM lt MSISDN1_string gt lt MSISDN1 gt lt MSISDN1_type gt lt CR gt lt LF gt CNUM lt MSISDN2_string gt lt MSISDN2 gt lt MSISDN2_type gt lt CR gt lt LF gt ia OK CNUM CNUM MSISDN not supported CNUM lt phone_number gt OK The following table shows the CNUM parameters lt Parameter gt Description lt MSISDN type gt Phone number type 129 Use
279. s a waiting call a CCWA indication is sent from the H3xx to the terminal The indication will appear one time Note functionality The H3xx supports only one of the services at a time Voice or Data Multiparty is a voice only A CCWA indication is sent to the terminal only during a voice call waiting event A CCWA indication is not sent for a data call during in a voice session Command Syntax Response Remarks Set CCWA lt n gt lt OK The Set command enables disables moneri sgass If lt mode gt 2 and the the Call Waiting indication in the H3xx command succeeds f a and in the network Activation CCWA deactivation and status query are lt status gt lt class gt lt C Supported R gt lt LF gt Note When the lt mode gt parameter is CCWA set to 2 network query the lt n gt lt status gt lt class gt parameter is ignored This means that LJ no enable disable action is performed E while querying the network OK Read CCWA CCWA lt n gt The Read command returns the OK enable disable status of the call waiting indication in the H3xx lt n gt lj Test eer ae eno ANSEO The Test command returns lt n gt values supported lt n gt s supported by the H3xx as a compound H3 Family AT Commands User Manual Page 63 of 375 FIDCCON OK value The following table shows the lt class gt parameters lt Class gt Desc
280. s been placed on hold during the call using the CHLD AT command and m enable 5 6 2 CUSD Unstructured Supplementary Service Data This command allows control of Unstructured Supplementary Service Data US SD according to GSM 02 90 Both network and mobile initiated operations are supported Parameter lt n gt is used to disable enable the presentation of an unsolicited result code USSD response from the network or network initiated operation CUSD lt m gt lt str gt lt dcs gt to the TE In addition value lt n gt 2 is used to cancel an ongoing USSD session When lt str gt is given a mobile initiated USSD string or a response USSD string to a network initiated operation is sent to the network The response USSD string from the network is returned H3 Family AT Commands User Manual Page 99 of 375 FIDCCON in a subsequent unsolicited CUSD result code Command Syntax Response Action Remarks Set AT CUSD OK The Set command lt n gt lt str a enables disables the display of gt lt dcs gt the unsolicited result code CME ERROR lt err gt Unsolicited CUSD The USSD response from the Report lt m gt lt str gt lt dsc gt ewes Read CUSD CUSD lt n gt The Read command displays OK the current value of lt n gt Test CUSD CUSD list of The Test command displays the supported lt n gt s supported values of lt n gt OK The following table shows the CUSD para
281. s in the network 0 CLIR not provisioned 1 CLIR provisioned in permanent mode 2 Unknown for example no network and so on 3 CLIR Temporary mode presentation restricted can be the default 4 CLIR Temporary mode presentation allowed can be the default Example AT CLIR CLIR 0 2 OK AT CLIR CLIR 0 0 AT CLIR 2 OK atd054565195 MO voice call OK calling a H3xx that has 054565195 SIM and is CLIP enabled will receive the following on the terminal RING H3 Family AT Commands User Manual Page 73 of 375 FIDCCON CLIP 128 128 1 RING CLIP 128 128 1 ath NO CARRIER OK AT CLIR 0 OK atd054565195 IMO voice call OK calling a H3xx that has 054565195 SIM and is CLIP enabled will receive the following on the terminal RING CLIP 054565006 129 128 0 RING CLIP 054565006 129 128 0 ath OK NO CARRIER 5 3 14 CBST Select Bearer Service Type This command sets the bearer service data circuit duplex asynchronous and synchronous It chooses one of the bearer services the data rate of the service actually the modulation when modem IWFs are used and enables or disables the Radio Link Protocol Command Syntax Response Action Remarks Set AT CBS OK The Set command selects the bearer T lt spe CME ERROR service lt name gt with data rate lt speed gt ed gt lt n 2 and t
282. s not available 3 Circuit switched preferred use GPRS if circuit switched is not available Other values are reserved and will result in an ERROR response to the Set command Example AT CGSMS CGSMS 0 3 OK AT CGSMS CGSMS 1 OK 7 1 20 CMGS Send SMS to Network This command sends an SMS from the H3xx to the network The message reference value lt mr gt is returned to the H3xx upon successful delivery of the message Valid lt toda gt will be any value between 128 255 The header parameters in TEXT mode will be set according to CSMP settings gt lt CR gt text is entered lt ctrl Z ESC gt If PDU mode CMGS ERROR lt err gt Command Syntax Response Action Remarks Set If text mode CMGS lt mr gt The Set command CMGF 1 OK validates the input CMGS lt da gt lt toda parameters sends the SMS to network and reports the result of the operation to the H3xx H3 Family AT Commands User Manual Page 158 of 375 FIDCCON CMGF 0 CMGS lt length gt lt C R gt PDU is entered lt ctrl Z ESC gt The following table shows the CMGS parameters lt Parameter gt Description Destination address in quoted string This field contains a single MIN lt da gt number lt toda gt Type of DA Value between 128 255 according to GSM 03 40 9 1 2 5 If this field is not given and first character of lt da gt is lt to
283. s not currently searching for a new operator to register 1 Registered home network 2 Not registered but the ME is currently searching for a new operator to register 3 Registration denied 4 Unknown 5 Registered roaming lt lac gt Two byte location area code in hexadecimal format lt ci gt Four byte cell ID in hexadecimal format H3 Family AT Commands User Manual Page 180 of 375 FIDCCON It is a Release 7 feature and describes access technology of the registered network Possible values of lt AcT gt are lt AcT gt 0 GSM 1 GSM Compact 2 UTRAN It is Release 7 feature string type one byte routing area code in lt rac gt hexadecimal format Intel Mobile Example att cgreg CGREG 0 2 OK AT CGREG 2 OK AT CGREG CGREG 2 1 A52F 0160358F 6 02 OK AT CGREG 1 OK AT CGREG CGREG 1 1 OK AT CGREG 0 OK 9 1 5 COPS Operator Selection This command enables accessories to access the network registration information and the selection and registration of the GSM UMTS network operator The H3xx is registered in the Home network The Enhanced Operator Name String EONS feature enables the H3xx to return the operator name displayed on the handset This feature allows the SIM card to store a mapping of MCC MNC code pairs to the displayed operator H3 Family AT Commands User Manual Page 181 of 375 FIDCCON name As a result several operators can share a single net
284. s of 50 msec for the S12 255 20 escape character during CSD connections Note SO Auto Answer should work regardless of the DTR HW line state This is a deviation from the ITU V 25 ter standard For H350 xxx 10 H380 only SO S4 and S7 are supported Example ATS0 000 OK ATS0 3 OK ATS0 003 OK H3 Family AT Commands User Manual Page 31 of 375 FIDCCON 4 1 6 S2 This command handles the selection of the escape characters which are stored in S Register 2 and specifies the escape character used in CSD connections Command Syntax Response Action Remarks Set S2 lt esca OK The Set command sets the CSD pe_charac CME ERROR lt err gt amp SCaPe character value if all ter gt parameters are valid Read 2 lt escape_character gt The Read command displays the OK currently defined escape character for CSD connections The following table shows the S2 parameters lt Parameter gt Description lt escape_character gt CSD escape character Range is 1 to 255 The default value is 43 4 1 7 12 This command handles the selection of the guard time which is stored in S Register 12 and specifies the behavior of escape characters during CSD connection Note For a guard time specified by S Register 12 no character should be entered before or after The duration between escape codes must be smaller than the guard time C
285. s of data Command Syntax Response Action Remarks Set MIPSEND lt ERROR Data in the MIPSEND Socket_ID gt lt D MIPSEND command is limited to 1024 ata gt lt Socket_ID gt lt status gt lt FreeSiz characters 2048 in coded as form Read MIPSEND MIPSEND lt Socket_ID gt lt FreeSize gt gt lt Soc ket_ID gt FreeSize gt lt CR gt lt LF gt OK For all ACTIVE sockets The following table shows the MIPSEND parameters lt Parameter gt Description lt socket_ID gt 1 2 3 4 Number of valid socket lt status gt 0 Send data to socket buffer OK 1 MIPXOFF received before send failed lt FreeSize gt Free space in current buffer Free size is calculated from the 2048 O lt Free Size lt 2048 lt Data gt User data string is sent encoded with 0 F hexadecimal digits String ends H3 Family AT Commands User Manual Page 318 of 375 FIDCCON with a lt CR gt Example Socket 4 was not opened using MIPOPEN AT command AT MIPSEND 4 4444 ERROR AT MIPSEND 1 4444 MIPSEND 1 2046 OK AT MIPSEND ERROR AT MIPSEND MIPSEND 1 2048 MIPSEND 2 2048 OK 13 6 2 Send Data at HEX Mode 12048 2 chars DD 2046 Sockets 1 and 2 were opened using MIPOPEN AT command Base on the basic mode H3xx achieve the TCP IP stack by AT command In addition to the basic Mode the H3xx supports TCP IP Stack Hex Mode The data will be sen
286. s of the H command Call State Response Action IDLE Error operation not allowed Single Active Call released MTPY Active Call released all calls Incoming call RING Call released Single Active and Waiting Call Single Active released waiting not affected MTPY Active and Waiting Call MTPY Active released waiting not affected Single or MTPY Active and Single or MTPY Held Single or MTPY Active released Held Single or MTPY and Waiting Call Waiting call released Single or MTPY Active and Single or MTPY Held amp Single or MTPY Active released Waiting call Example RING Incoming call RING Incoming call ath Hang up incoming call H3 Family AT Commands User Manual Page 55 of 375 FIDCCON NO CARRIER _ Incoming call has been terminated user determined user busy RING ata OK Noice call connected ath Hang up connected call OK NO CARRIER Active call has been hung up terminated Active multi party call with 3 numbers ath OK NO CARRIER NO CARRIER NO CARRIER atd035659260 OK ath Terminate MO voice call while placed OK NO CARRIER Example Hanging up a data call atd035659260 CONNECT Data call connected Online Data mode IESC Sequence is sent from the terminal to the H3xx OK The H3xx is in Command mode ath Terminate Data call OK NO CARRIER 5 3 5 A Answer Incoming Call This command answers an incoming
287. s the effect that setting this parameter has on the format of information text and result codes vo v1 Information Responses lt ATV0 gt lt cr gt lt lf gt lt ATV1 gt lt cr gt lt lf gt 0 OK lt numeric code gt lt cr gt lt verbose code gt lt cr gt lt lf gt tonne e 2 RING 3 NO CARRIER 4 ERROR 5 NO DIALTONE 6 BUSY 7 NO ANSWER Command Syntax Response Action Remarks Set ATV lt value gt OK The Set command sets the format of r information responses and result codes CME ERROR lt err gt FIDCCON The following table shows the V parameters lt Parameter gt Description lt value gt 0 Transmits limited headers and trailers and numeric text 1 Transmits full headers and trailers and verbose response text The default value is 1 Example ATVO 0 ATV1 OK 4 1 2 Q Result Code Suppression This command determines whether to output the result codes Information text transmitted in response to commands is not affected by the setting of this parameter Note For H350 xxx 10 H380 Read command are not supported Command Syntax Response Action Remarks Set ATQ lt value gt OK The set commands sets whetheror Git not to output result codes CME ERROR lt err gt Read ATQ Q lt value gt OK The following table shows the Qn parameters lt Parameter gt Descripti
288. s the radio access technology and may be 0 GSM single mode 1 GSM UMTS Dual mode 2 UTRAN UMTS lt PreferredAct gt This parameter is used for network registration in case of lt AcT gt 1 H3 Family AT Commands User Manual Page 201 of 375 FIDCCON 0 RAT GSM 2 RAT UMT H3 Family AT Commands User Manual Page 202 of 375 FIDCCON 10 Hardware Information 10 1 Uart Parameter Commands Note For H350 xxx 10 H380 No UART commands are supported 10 1 1 CBAUD Baud Rate Regulation This command sets the uniquely UART baud rate The baud rate of H3xx will be change set to the request value lt rate gt which is get from the command Specifying a value of 0 1 or 9 allows operation only at rates automatically detectable by H3xx The specified rate takes effect following the issuing of any result code s associated with the current command line Note ATZ and AT amp F command sets H3xx to default baud rate 0 In auto baud must sent an AT command to H3xx firstly After sent any AT command the module will lock on single baud rate this AT command will be lost and can not get response from H3xx Read command can feedback the currently baud rate The module can not be changed to auto baud without send AT CBAUD 0 1 or 9 command or after power cycle H3xx auto baud rate detect supports the next baud rates 1200 2400 4800 9600 19200 38400 57600 115200 230400 The parameter can t be saved after power up
289. s_nack_ind_req gt lt CR gt lt LF gt MIPCONF 4 lt retr_num gt lt min_TO gt lt m ax_TO gt lt max_close_delay gt lt is_nack_ind_req gt lt CR gt lt LF gt OK Test MIPCONF MIPCONF The Test command 1 4 1 12 1 10 10 600 __ returns the possible 1 75 0 2 parameters values OK Time values can be inserted with resolution of 100 milliseconds H3 Family AT Commands User Manual Page 329 of 375 FIDCCON Parameter Description lt socket_ID gt Number of configured TCP socket 1 to 4 lt retr_num gt Number of retransmissions 1 to 12 default 12 lt min_TO gt Bottom limit to retransmit timeout 100 ms to 1 sec default 500 ms lt max_TO gt Upper limit to retransmit timeout 1 sec to 60 sec default 60 sec lt max_close_delay gt Closing delay required by RFC 793 100 ms to 7500 ms default 7500 ms lt is_nack_ind_req gt NACK ACK TCP indication feature Activating this parameter enables H3xx to report the user in case of losing a TCP connection what data was received by the remote TCP layer 0 feature inactive 1 NACK indication active 2 ACK indication active Example AT MIPCONF 2 5 10 600 75 2 OK AT MIPOPEN 2 0 66 249 87 99 80 0 OK MIPOPEN 2 1 AT MIPSETS 2 10 MIPSETS 0 OK AT MIPSEND 2 474554202F20485454502F312E300D0A486F 73743A207777772E6 6F6F6 76C6 52E636 F6DODOAODOA MIPPUSH 2 0 40 MIPSEND 2 0
290. se is 129 local number Read CSCA CSCA Read command displays lt sca gt and lt sca gt lt tosca gt lt tosca gt stored in SIM EF SMSp OK Test The Test command for CSCA is not defined by ETSI The following table shows the CSCA parameters lt Parameter gt Description lt sca gt Service Center Address character prefix of lt sca gt indicates lt tosca gt of 145 Minimum 1 and up to 20 characters where each character is represented by semi octets excluding character If lt sca gt contains an odd number of digits bits 4 to 7 of the last octet H3 Family AT Commands User Manual Page 124 of 375 FIDCCON shall be filled with an end mark coded 1111 lt tosca gt Type of service center address lt tosca gt of 129 is mostly use for local number and 145 for International lt tosca gt of 129 is default value lt tosca gt values are in range of 0 255 Valid values are defined according to GSM03 40 v7 4 0 section 9 1 2 5 as follow Bit 7 is 1 Bits 6 5 4 Present Type of number as follow Bits 6 5 4 0 0 0 Unknown 0 0 1 International number 0 1 0 National number 0 1 1 Network specific number 1 0 0 Subscriber number 1 0 1 Alphanumeric coded according to GSM TS 03 38 7 bit default alphabet 1 1 0 Abbreviated number 1 11 Reserved for extension Numbering plan identification applies for Type of number 000 001 010
291. se to FTPRECV command and other non FTP command it only shows ERROR when executs other FTP command After the module receives the data it doesn t transfer to the serial port directly instead it stores the data in the cache If the user wants to get the downloaded data please use FTPRECV command When the buffer is full in the module it will exit from the command module after get all data by FTPRECY it will enter this mode again and fill buffer then exit from FTPGET module the cycle repeats until the file read successfully After return OK it still cannot get the data as it need a procedure to establish the connection and download to buffer AT FTPRECV can be used for reading data after FTPGET 2 comes up can first use AT FTPRECV to request the data size of current buffer So far the size of buffer is 30k Command Syntax Response Action Remarks Set FTPGET lt filena OK me gt lt viewmode T lt file_name gt is a complete qualified path gt lt offset gt and file name on the server site ERROR lt Offset gt is the file offset address already exists on the server this means the server support file transfer resume The command execution result return to the user as an unsolicited response 0 operation fails 1 operation success 2 already download data to cache Read FTPGET FTPGET lt filename gt lt viewm Read the command mode state ode gt lt eof gt OK H3 Fami
292. serving cell BSIC gt lt signal strength gt lt TA gt lt neighbor 1ARFCN gt lt neighbor 1 BSIC gt lt signal strength gt lt neighbor 2 ARFCN gt lt neighbor 2 BSIC gt lt signal strength gt lt neighbor 3 ARFCN gt lt neighbor 3 BSIC gt lt signal strength gt lt neighbor 4 ARFCN gt lt neighbor 4 BSIC gt lt signal strength gt lt neighbor 5 ARFCN gt lt neighbor 5 BSIC gt lt signal strength gt lt neighbor 6 ARFCN gt lt neighbor 6 BSIC gt lt signal strength gt The following table shows the MCI parameters lt Parameter gt Description lt ARFCN gt Absolute Radio Frequency Channel Number Range 1 124 128 251 512 885 975 1023 H3 Family AT Commands User Manual Page 199 of 375 FIDCCON lt BSIC gt Base transceiver Station Identity Code Range 0 63 lt signal Range 110 48 dBm strength gt For serving cell signal strength is defined as e In dedicated mode TCH Rx level In idle mode average BCCH Rx level For adjacent cells signal strength is defined as the average Rx level in the both modes lt TA gt TA Timing Advance is defined for serving cell only This value will be reported only in Dedicated and TBF modes Valid value range is from 0 to 63 Example AT MCI MCI 15 0 OK AT MCI 1 OK MCI 712 33 93 AT MCI 1 0 OK MCI 712 33 92 AT MCI 1 1 OK MCI 712 33 93 AT MCI 2 1
293. successful the result of operation CMSS lt mr gt will be reported by H3xx If after aborting AT CMSS command execution and before result of operation was reported by H3xx a second AT CMSS command is executed then the result of the second AT CMSS operation only will be reported by H3xx 7 1 17 CMGW Write Message to Memory This command is used to write and save a message to lt mem2 gt The message is saved in memory and the message index is displayed to the user By default messages are saved with the status of STO UNSENT but status STO SENT can be applied using the lt stat gt parameter In TEXT mode the header parameters will be set according to CSMP settings Command Syntax Response Action Remarks Set If text mode CMGF 1 CMGW lt index gt The Set command CMGW lt da gt lt toda gt lt stat gt lt C or writes a message R gt text is entered lt ctrl Z ESC gt and stores it CMS ERROR if PDU mode CMGF 0 lt err gt H3 Family AT Commands User Manual Page 153 of 375 FIDCCON CMGW2 lt length gt lt stat gt lt CR gt PDU is given lt ctrl Z ESC gt Example AT CMGF 1 OK AT CMGW2 5124335432 gt This is the message body lt CTRL Z gt lt CTRL Z gt ends the prompt text mode and returns to regular AT command mode CMGW 126 OK AT CMGW gt TEST lt CTRL Z gt CMGW 195 OK AT CMGF 0 OK AT CMGW 24 gt 079
294. supported 0x68 0x00 Check Error no information provided 0x68 0x81 Check Error logical channel not supported 0x68 0x82 Check Error secure messaging not supported 0x69 OxXX Check Error command not allowed 0x69 0x00 Check Error no information provided 0x69 0x81 Check Error command incompatible with file structure 0x69 0x82 Check Error security status not satisfied 0x69 0x83 Check Error authentication method blocked 0x69 0x84 Check Error referenced data invalidated 0x69 0x85 Check Error conditions of use not satisfied 0x69 0x86 Check Error command not allowed no current EF 0x69 0x87 Check Error expected SM data objects missing 0x69 0x88 Check Error SM data objects incorrect Ox6A OxXX Check Error wrong parameters Ox6A 0x00 Check Error no information provided Ox6A 0x80 Check Error incorrect parameters in data field Ox6A 0x81 Check Error function not supported Ox6A 0x82 Check Error file not found Ox6A 0x83 Check Error record not found Ox6A 0x84 Check Error not enough memory space in the file Ox6A 0x85 Check Error Lc inconsistant with TLV structure Ox6A 0x86 Check Error inconsistant parameters P1 P2 Ox6A 0x87 Check Error Lc inconsistant with P1 P2 Ox6A 0x88 Check Error referenced data not found Ox6B OxXX incorrect parameter P1 or P2 Ox6C OxXX Check Error wrong length xx is the correct length H3 Family AT Commands User Manual Page 41 of 375 FIDCCON Ox6D 0xXX unknown inst
295. sv_connection 26 uta_audio_tone_sv_disconnect 27 uta_audio_tone_sv_device_in 28 uta_audio_ tone _sv_ device_out 29 uta_audio_tone_sv_msg_full 30 uta_audio_tone_sv_ussd 31 uta_audio_tone_sv_minutte_minder 32 uta_audio_tone_sv_error_1 33 uta_audio_tone_sv_error 2 34 uta_audio_tone_sv_sms_in_call 35 uta_audio_tone_sv_broadcast_in_call 36 uta_audio_tone_sv_alarm_in_call 37 uta_audio_tone_sv_low_bat_in_call 38 uta_audio_tone_sv_power_off 39 uta_audio_ tone _sv_power_on 40 uta_audio_tone_sv_single_beep 41 uta_audio_tone_sv_positive_ acknowledgement 42 uta_audio_tone_sv_negative_acknowledgement 43 uta_audio_tone_sv_auto_redial 44 uta_audio_tone_sv_network_attention 45 uta_audio_tone_sv_dial_tone H3 Family AT Commands User Manual Page 252 of 375 FIDCCON 46 uta_audio_tone_sv_low_bat 47 uta_audio_tone_sv_test_call lt nof_play_ti mes gt Integer indicating the amount of tone repetitions range 0 32767 Ox7FFF 0 means repeats for ever for other values a response is returned when the tone generation is finished See further DWD Audio driver interface specification lt mix_fac tor gt lt mix_factor gt integer indicating the kind of volume for tone generation range 1 7 lt result gt lt result gt integer indicating the overall result of the command may be 0 RESULT_OK 1 RESULT_PARAM_OUT_OF_RANGE 2 RESULT_DRV_NOT_SUPPORTED 3 RESULT_AUD_ RESOURCE_NOT_AVAI L 4 RESULT OTHER ERROR
296. t lt page gt lt pages gt lt CR gt lt LF gt lt data gt If text mode CMGF 1 command execution is successful and SMS STATUS REPORT Command Syntax Response Action Remarks Set CMGR lt index If text mode CMGF 1 command execution is The Set gt successful and SMS DELIVER command CMGR reads the SMS located at lt index gt in the H3xx message storage and displays it H3 Family AT Commands User Manual Page 148 of 375 FIDCCON CMGR lt stat gt lt fo gt lt mr gt lt ra gt lt tora gt lt scts gt lt dt gt lt st gt If PDU mode CMGF 0 and command execution is successful CMGR lt stat gt lt alpha gt lt length gt lt CR gt lt LF gt lt pdu gt otherwise CMS ERROR lt err gt The following table shows the CMGR parameters lt Parameter gt Description lt index gt Index in storage of the message to be retrieved lt stat gt Status of message in memory PDU mode Text mode Description A MrA LIRID Om AMY Ln ee ee es A DCO DCAD Danniund rand manannna be OTA LINIOCEAIT Otara sinnan t manannnnan e OTA CEKIT Otarnd nannt mannanna A All All lt alpha gt Alpha ID of message not present In PDU mode Size of message in octets excluding SMSC data lt length gt In TEXT mode Number of characters included in lt data gt Message header and contents in PDU mode format lt p
297. t lt pages gt lt CR gt lt LF gt lt data gt lt CR gt lt LF gt H3 Family AT Commands User Manual Page 144 of 375 FIDCCON CMGL lt index gt lt stat gt lt sn gt lt mid gt lt page gt lt pages gt lt CR gt lt LF gt lt data gt If text mode CMGF 1 command execution is successful and SMS STATUS_REPORTs CMGL lt index gt lt stat gt lt fo gt lt mr gt lt ra gt lt tora gt lt s cts gt lt dt gt lt st gt lt CR gt lt LF gt CMGL lt index gt lt stat gt lt fo gt lt mr gt lt ra gt lt tora gt lt s cts gt lt dt gt lt st gt In PDU mode CMGF 0 CMGL lt index gt lt stat gt lt alpha gt lt length gt lt CR gt lt L F gt lt pdu gt lt CR gt lt LF gt CMGL lt index gt lt stat gt lt alpha gt lt length gt lt CR gt lt L F gt lt pdu gt Or CMS ERROR lt err gt Test CMGL CMGL list of supported lt stat gt s The Test command lists all the supported lt stats gt The following table shows the CGML parameters lt Parameter gt Description lt index gt 1 352 Index of message in storage H3 Family AT Commands User Manual Page 145 of 375 FIDCCON H3 Family AT Commands User Manual lt stat gt Status of message in memory PDU mode Text mode Description seus dee n KOTA LING
298. t 108 BEMAVION a ixs a csasieissesstnaeadlaigratianeetndnnanmeeuiendueniaea e E E E S 210 10 1 7 ICF DTE DCE Character Framing cccccccccccccsscscsseescsscescsscsecsecsessccsessessesecseesecseseceseseesaes 211 10 2 Other Parameter CR INARI Sich aciesaiesopsacagiss at cauaa sbavigh toa coeacanbaconaumaci aca auc manna ela pneoananraan lew andacrryne 213 10 2 1 CBC Battery Charger Connection ccccccccccccccsesscssesecsseseeseescesesscscsecsecsecsecseeseeecseseecseenees 213 10 2 2 CFUN Shut Down Phone Functionality cc cccccssccseeseseeseseeseseeecseecsenecseeecsesenseeeeeeeeeeeeees 214 1023 CPWROFF Switehioff MS sisii erreen ape a e ri e eai ea E teas 216 10 2 4 MMAD Query and Monitor ADC Value ccc cc ccccccsccsessccsesecsseseeseesceseecsecsecsecseesecseeseeeeseees 216 10 2 5 MTSM Temperature Sensor MeaSureMe ih cccccesccsssscesesscscsecsscsceseceesaceecsececseeseeaee 217 10 2 6 WRIM RI Signal Width Setting cece ccesccsseesecsecssecseeeseeseceseesecescesecseceseeseceseesseeeesseeseeesee 220 10 2 7 MSTART Start Message Notification ec cccccsecscssceecsecseesecseeseeseecssesecsseseessssceseneeeees 221 10 2 8 MSMPD Enable Disable SIM Card hot Plug ec ccsseessssesesseeceseecsecseeeseeeseeeeseeeteeeeeeeesaes 222 10 2 9 SEP IO Set anid Read GPs nearen r Err erraren er E Eei 223 10 2 10 GTFMODE Enable Disable hardware pin control flight MOd cc cece eseesecseeteeeeeaes 225 10 2 11 GTWAKE Enabl
299. t after receiver a SMS within the required time CNMI parameters will NOT be reset automatically and the CMT unsolicited response will send to the TE again Example AT CNMI 1 2 OK AT CSDH 1 OK AT CMSS 142 054565034 send to myself CMSS 74 OK CMT 972544565034 04 11 04 09 48 36 08 145 4 0 0 97254120032 145 3 ABC AT CNMA OK AT CMGF 0 OK AT CMGS 18 send to myself gt 079179521201009511000c917952446505430004AA0441 424344 CMGS 70 OK CMT 23 0791795212010095040C917952446505430004502032 11543080044 1424344 7 1 11 CBM Unsolicited Response New CB Message Receipt The CBM unsolicited response is sent to the TE upon receipt of a new cell broadcast message if CNMI parameter lt bm gt is set to 2 Refer to t CNMI New Message Indications to Terminal This unsolicited message displays the received CB message The displayed CBM is not saved in message storage Unsolicited Response In text mode CMGF 1 CBM lt sn gt lt mid gt lt dcs gt lt page gt lt page gt lt CR gt lt LF gt lt data gt H3 Family AT Commands User Manual Page 140 of 375 FIDCCON In PDU mode CMGF 0 CBM lt length gt lt CR gt lt LF gt lt pdu gt The following table shows the CBM parameters lt Parameter gt Description lt sn gt Message serial number lt mid gt Message ID lt page gt Current page number lt pages gt Total number of
300. t audio features The lt features gt field is only used for outputs direct 1 Read MAPATH MAPATH 1 mode The Read command returns the in lt accy gt lt CR gt lt LF gt M _ active input audio accessory and the APATH 2 mode output accessory for each feature out lt accy gt lt CR gt lt LF gt O K If GTCODECN choose chip ALC5621 it return er MAPATH 1 mode in and MAPATH 1 mode in and out lt accy gt lt CR gt lt LF gt OK out lt accy gt lt CR gt lt LF gt O If CS42L73 is selected it return K MAPATH 1 mode in lt accy gt lt CR gt lt LF gt MAPATH 2 mode out lt accy gt lt CR gt lt LF gt OK Test MAPATH MAPATH list of The Test command returns the supported directions list supported audio directions of supported accessories input output accessories and OK features The results is related to the chip selection of GTCODECN The following table shows the MAPATH parameters lt Parameter gt Description lt direct gt If you use ALC5621 1 Audio channel input and output H3xx default If you use CS42L73 1 Audio channel input H3xx H3 Family AT Commands User Manual Page 246 of 375 FIDCCON 2 Audio channel output from H3xx lt accy gt Audio channel input module If you use ALC5621 1 1st channel MIC MIC and AUXI AUXI Default 2 2nd channel MIC MIC and AUXI AUXI If you use CS42L73 1 1stchannel M
301. t in HEX when we use MIPSEND command There are two methods send data at unfixed length and send data at fixed length Send data at unfixed length data end with Ctrl Z Ctrl Z character 0x1A can not be send at this method data length gt MIPSEND lt Socket_ID gt lt Status gt lt FreeSiz e gt or ERROR Command Syntax Response Action Remarks Set MIPSEND lt MIPPUSH After command received Socket_ID gt lt Socket_ID gt lt Status gt lt pushed H3xx will respond gt lt CR gt lt LF gt Send any data in HEX The data buffer range is 0 lt buffer lt 1400 bytes lt CTRL Z gt ends the prompt HEX mode and returns to regular AT command mode H3 Family AT Commands User Manual Page 319 of 375 FIDCCON Notes If there is any data in the buffer sent by previous mipsend H3xx will reply ERROR to TE Example Socket 2 already open AT MIPSEND 2 gt This is the data in HEX lt CTRL Z gt lt CTRL Z gt ends the prompt HEX mode and returns to regular AT command mode OK MIPPUSH 2 0 MIPSEND 2 0 2048 OK Send data at unfixed length data end with timeout Ctrl Z character 0x1A can not be send at this method Command Syntax Response Action Remarks Set MIPSEND MIPPUSH After command received H3xx will lt Socket_I lt Socket_ID gt lt Status gt lt pushed respond gt lt CR gt lt LF gt pe pata lengis Send any data with
302. t s list of supported lt Timeout gt s OK The following table shows the MIPSETS parameters lt Parameter gt Description Size Size of the buffer 1 lt size lt 2048 The default value is 2048 Timeout 0 1000 0 means no timeout is used default Extended err 3 Operation not allowed H3 Family AT Commands User Manual Page 315 of 375 FIDCCON Example AT MIPSETS 1 340 Asks the H3xx to accumulate 340 bytes on socket 1 prior to sending socket should be activated by the mipopen command MIPSETS 0 OK AT MIPSETS 2 400 Asks the H3xx to accumulate 400 bytes on socket 2 prior to sending MIPSETS 0 OK AT MIPSETS MIPSETS 1 4 1 2048 0 1000 OK AT MIPSETS MIPSETS 1 200 0 Information provided only for active sockets MIPSETS 2 400 0 Information provided only for active sockets OK AT MIPSETS 1 200 50 Asks the H3xx to send all accumulated data after 50 msec of receiving data in mipsend command MIPSETS 0 OK AT MIPSETS MIPSETS 1 200 50 MISETS 2 400 0 OK 13 5 MIPDSETS Set Size and Timeout for Output Data This command causes the H3xx to set a max length and time span when send received data to TE The max length means the data which H3xx send to TE must less than this length Time span is used to define interval of time between two package when send data to TE Command Syntax Response Action Remarks Set MIPDSETS lt Soc OK Time sp
303. ted Command Syntax Response Action Set MATONE lt state gt lt tone_id OK gt lt nof_play_times gt lt mix_fa T c tor gt CME ERROR lt err gt Read MATONE MATONE lt result gt lt aud_ret_code gt OK Test MATONE MATONE lt state gt lt tone_id gt lt nof_play_times gt lt mix_fac tor gt OK H3 Family AT Commands User Manual Page 250 of 375 FIDCCON The following table shows the MATONE parameters lt Parameter gt Description lt state gt 0 stop When state 0 lt tone_id gt 0 lt nof_play_times gt 0 lt mix_factor gt 0 means the tone is stop 1 start lt tone_id gt lt tone_id gt integer indicating the audio tone ID and may be 0 aud_tone_ DTMF_0O 1 aud_tone_DTM F_1 2 aud_tone_DTMF_2 3 aud_tone DTMF_3 4 aud_tone_DTMF_4 5 aud_tone_ DTMF_5 6 aud_tone DTMF_6 7 aud_tone_ DTMF_7 8 aud_tone DTMF_8 9 aud_tone DTMF_9 10 aud_tone_ DTM F_hash 11 aud_tone_DTMF_asterix 12 uta_audio key _tone_1 13 uta_audio_key_tone 2 14 uta_audio_key_tone_ 3 15 uta_audio_key_tone 4 16 uta_audio_key_tone_5 17 aud_tone_sv_subscriber_busy 18 aud_tone_sv_congestion H3 Family AT Commands User Manual Page 251 of 375 FIDCCON 19 aud_tone_sv_radio_path_ack 20 aud_tone_sv_radio_path_not_avail 21 aud_tone_sv_error_i nfo 22 aud_tone_sv_call_ waiting 23 aud_tone_info_free_tone 24 uta_audio_tone_sv_free_tone 25 uta_audio_tone_
304. tets unsigned digit 0 4294967295 lt Status gt 0 Success 1 socket is flowed off 2 there is no data in socket to send Read MIPPUS MIPPUSH H lt socket_ID gt OK Test MIPPUS MIPPUSH lt socket_ H3 Family AT Commands User Manual Page 324 of 375 FIDCCON H D gt lt IP gt lt Port gt OK The following table shows the MIPPUSH parameters lt Parameter gt Description Socket_ID 1 2 3 4Number of valid socket Destination_IP IP of destination site in the format AAA BBB CCC DDD The value can be written int 2 or 3 digits Destination_ Port 0 65535Port of destination site Written in decimal digits Example AT MIPPUSH 1 Terminal asks the H3xx to flush the buffer in socket 1 was opened using the MIPOPEN command MIPPUSH 1 0 10 10 bytes has been pushed into protocol stack OK 13 9 MIPFLUSH Flush Data from Buffers This command causes the H3xx to flush delete data accumulated in its accumulating buffers Command Syntax Response Action Set MIPFLUSH lt Socket_ID gt MIPFLUSH lt Socket_ID gt OK or ERROR Read MIPFLUSH MIPFLUSH lt socket_ID gt OK Test MIPFLUSH MIPFLUSH lt Socket_ID gt OK H3 Family AT Commands User Manual Page 325 of 375 FIDCCON The following table shows the MIPFLUSH parameters lt Paramete
305. the DCE or TA such as the phone the mobile or the radio The terminal PC or MCU may be referred to as the DTE or the TE 2 3 AT Commands Protocol The AT commands interface is basically a Modem Services upon Request Communication almost always begins from the TE side This means that any service should be requested from the TE Thus a request is called a Command Each command must be answered by a Results code from the TA The results code reports the command status to the TE Some commands may include several Results code to send data back to the TE Some commands may initiate a mode in which when specified events are generated in the H3xx Indicator messages are sent data asynchronously The indicators can be called Unsolicited results code The H3xx can echo characters received from the TE commands back to the TE FIDCCON TE TA H3xx Command Results code TE TA H3xx Command Results code eee TE TA H3xx Unsolicited results code 2 4 AT Commands Structure 2 4 1 General Symbols Used in AT Commands Description The following syntax definitions apply in this chapter Syntax Definition lt CR gt Carriage returns character specified by the value of the S3 register lt LF gt Line feed character specified by the value of the S4 register H3 Family AT Commands User Manual Page 15 of 375 FIDCCON Name enclosed in angle brackets is a syntax eleme
306. the V 250 command state is re entered and the MT returns the final result code OK H3 Family AT Commands User Manual Page 296 of 375 FIDCCON Example AT CGDATA ppp CONNECT AT CGDATA CGDATA PPP M OPT PPP M HEX M RAW_IP PAD X25 OK 12 2 16 CGDSCONT Define Secondary PDP Context This command is used to define a secondary PDP context by specifying the PDP context parameter values for a lt cid gt local context identification parameter If the command is used only with the one parameter lt cid gt it means that the corresponding PDP context becomes undefined Command Syntax Response Action Remarks Set CGDSCONT OK Set command specifies lt cid gt Or PDP context parameter lt p_cid gt values for a Secondary ERROR a lt d_comp gt lt PDP context identified by h_comp gt the local context identification parameter lt cid gt Read CGDSCONT CGDSCONT lt cid gt lt p_cid gt Read command returns lt d_comp gt lt h_comp gt the current settings for OK each defined context Test CGDSCONT CGDSCONT range of lt cid gt s list of Test command returns lt cid gt s for defined primary values supported as a contexts lt PDP_type gt list of compound value supported lt d_comp gt s list of supported lt h_comp gt s lt CR gt lt LF gt CGDSCONT range of lt cid gt s list of lt cid gt s for defined primary contexts lt PDP_type gt list of supporte
307. ticular PDP context definition See tCGDCONT Define PDP Context Example ATD 99 Try connecting to GPRS according to the first lt cid gt defined in CGDCONT 12 2 7 CGACT PDP Context Activate or Deactivate This command activates deactivates the specified PDP context s Command Syntax Response Action Remarks Set AT CGACT OK The Set command activates deactivates the lt state gt lt ci t specified PDP context s When the d gt lt cid gt command is completed the ME remains in NO CARRIER V 25 command state If any PDP context is or already in the requested state the state for CME ERROR lt err gt that context remains unchanged If the requested state for any specified context cannot be achieved an ERROR or CME ERROR response is returned Extended error responses are enabled by the CMEE command If the ME is not GPRS attached when the activation form of the command is executed the ME first performs a GPRS attach and them attempts to activate the H3 Family AT Commands User Manual Page 272 of 375 FIDCCON specified contexts If the attach fails the ME responds with an ERROR or if extended error responses are enabled with the appropriate failure to attach error message Read AT CGACT CGACT lt cid gt lt state gt lt CR gt lt L F gt CGACT lt cid gt lt state gt lt CR gt lt L F gt CGACT lt cid gt lt stat
308. tion gt s Notes e The MIPCALL command does not have a general ABORT mechanism therefore a command cannot be issued until the previous command ends e When a call exists the dynamic IP address will be returned For example AT MIPCALL MIPCALL 1 172 17 237 80 e Activating a context can take up to 150 seconds Deactivating a context can take up to 40 seconds If use AT MIPCALL 1 APN to activate PDP The cid 1 can not be actived e fuse AT MIPCALL 1 cid to activate PDP The APN must be set by AT CGDCONT command The following table shows the MIPCALL parameters FIDCCON lt Parameter gt Description operation 0 disconnect a link 1 establish GPRS link lt status gt 0 Disconnect 1 Connected APN APN of service provider in quotation marks Contact your service provider fordetails cid 1 10 set by cgdcont Local IP address IP address given by server after PPP negotiation Example AT MIPCALL 1 internet Connecting the provider Orange and getting an IP OK MIPCALL 1 123 145 167 230 AT MIPCALL 0 The terminal hangs up the link OK 13 2 MIPOPEN Open a Socket UDP or TCP This command causes the H3xx module to initialize a new socket that waits for a connection from a remote machine or opens a common connection with a remote side according to received parameters Each socket allocates two accumulating buffers 2048 bytes for sending and 8192 bytes for recei
309. tion is done through ATD 99 as described in D 99 Example atd44345678 VOICE call with semicolon OK OK atd44345678 IDATA call without semicolon CONNECT Move to online Data state 5 3 2 D gt Direct Dialing from Phone Books This command places a DATA VOICE call on the current network by dialing directly from the H3xx phone book Note e CME ERROR not found is returned when no match is found in an existing phone book e FD phone book supports the wild card character Telephone numbers containing this character cannot be dialed directly from the phone book e CME ERROR Invalid index is returned when entry lt n gt is out of the requested Phonebook range The following table shows a detailed description for the D gt commands Command Detailed Description D gt lt alpha gt Originates a call to a phone number with the corresponding alphanumeric field lt alpha gt The Current Phone Book Set by CPBS is searched for the entry that begins with the alphanumeric pattern lt alpha gt H3 Family AT Commands User Manual Page 52 of 375 FIDCCON D gt mem lt n gt Originates a call to a phone number in memory phone book mem and stored in entry location lt n gt D gt lt n gt Originates a call to a phone number from entry location lt n gt in the Current Phone Book Set by CPBS Note Current used memory phone book set read
310. tion part will be truncated Example AT MIPCALL 1 internet OK MIPCALL 10 170 4 111 Ping host www sohu com 3 times with lt TTL gt 255 All other parameters are default AT MPING 1 www sohu com 3 255 OK ICMP Echo Reply message received RTT is 522 ms MPING 121 14 0 17 0 0 522 MPINGSTAT 1 No corresponding reply within timeout MPINGSTAT 3 Flow Control OFF MPINGSTAT 4 Flow Control ON a new Echo Request message is sent immediately MPING 421 14 0 17 0 0 638 Ping request execution is completed Statistics displayed to terminal Three Echo Request messages were sent and two Echo Reply messages were received Average RTT is 580 H3 Family AT Commands User Manual Page 337 of 375 FIDCCON milliseconds MPINGSTAT 0 121 14 0 17 3 2 580 Ping host www sohu com 1 time with lt TTL gt 1 and lt size gt 1372 AT MPING 1 www sohu com 1 1372 1 OK I CMP Time Exceeded message received TTL expired in transit MPING 192 168 252 65 11 0 Ping request execution is completed MPINGSTAT 0 121 14 0 17 1 0 13 16 MSDNS Set DNS IP Address This command set read DNS Domain Name Server IP address primary secondary for each socket If the user doesn t specify DNS servers by AT MSDNS H3xx will use default DNS from NW The defined value s will be saved during disconnect PDP context can be used in next PDP context but will reset after power cycle
311. tion to on or off PIN23 is used to wake up host The default is High voltage 1 8V When the wake up host function is enabled if voice call SMS or data packet is coming PIN23 will output 1s low voltage Note For H330S H350 this command is not supported Command Syntax Response Action Remarks Set AT GTWAKE lt m_ OK Parameters are saved after ode gt or power down ERROR Read AT GTWAKE GTWAKE lt mode gt E g GTWAKE 0 OK or GTWAKE 1 OK Test AT GTWAKE GTWAKE 0 1 OK The following table shows GTWAKE parameter description lt Parameter gt Description lt mode gt 0 wake host is disable 1 wake host is enable Example AT GTWAKE 1 OK AT GTWAKE GTWAKE 1 OK AT GTWAKE GTWAKE 0 1 OK H3 Family AT Commands User Manual Page 226 of 375 FIDCCON 10 3 UART2 configuration There are two UARTs in H3xx module One is primary called UART1 and the other is assistanted called UART2 UART2 have two type of work mode One is for AT command another is for send receive user data The default mode is for AT command Please use AT GTSET UARTMODE lt mode gt to switch work mode The following table shows the UARTMODE parameters Note For H350 xxx 10 H380 No UART2 commands are supported lt Parameter gt Description lt mode gt 0 Uart2 use for AT command default 1 Uart2 use for send receive data 10 3 1 UAR
312. tion to the Execution Set and Test forms The following table shows the CGATT parameters lt Parameter gt Description lt state gt Indicates the state of the GPRS attachment 0 Detached 1 Attached Example AT CGATT CGATT 0 1 OK AT CGATT H3 Family AT Commands User Manual Page 269 of 375 FIDCCON CGATT 0 OK AT CGATT 0 OK 12 2 6 D 99 Request GPRS Service D This command enables the ME to perform the actions necessary for establishing communication between the terminal and the external Packet Data Network PDN The ITU V 25ter D Dial command causes the ME to enter the ITU V 25ter Online Data state and together with the terminal to start the specified layer 2 protocol The ME returns CONNECT to confirm acceptance of the command prior to entering the ITU V 25ter Online Data state No further commands may follow on the AT command line The detailed behavior after the Online Data state has been entered is dependent on the PDP type and is described briefly GPRS attachment and PDP context activation procedures may take place prior to or during the PDP startup if they have not already been performed using the CGATT and CGACT commands When the layer 2 protocols have terminated either as a result of an orderly shut down of the PDP or an error the ME enters the ITU V 25ter command state and returns the NO CARRIER final result code If lt called address gt is supported and provi
313. tions ITU l ETSI or manufacturer specific Command Syntax Response Action Remarks Set ATSn lt val OK The Set command is allowed for ue gt r read write S registers and not allowed for read only S registers CME ERROR lt err gt Read ATSn lt current value of S register n gt OK or CME ERROR lt err gt Test The Test command for Sn is not defined by ITU and therefore is not supported by the H3xx The H3xx returns an error The following table shows the different S registers and their associated values Min Max Default Sn Description Value Value Value SO Sets gets number of rings before auto answer 0 255 0 H3 Family AT Commands User Manual Page 30 of 375 FIDCCON S2 Sets gets escape code character 255 43 S3 Sets gets carriage return code character 127 13 S4 Sets gets line feed code character 127 10 Sets gets command line editing character S5 127 8 backspace Sets gets the amount of time in seconds that the DCE waits between connecting to the line and S6 10 2 dialing when dial tone is not implemented or enabled Sets the number of seconds in which connection S7 255 60 must be established before the call is disconnected Sets get the amount of time in seconds that the DCE S8 shall pause during dialing when a dial modifier is 255 2 encountered in a dial string Sets get guard time in unit
314. tive call 2x Place all active calls on hold except call x with which communication is supported Adds a held call to the conversation Connects the two calls and disconnects the subscriber from both calls Explicit Call Transfer Puts an active call on hold or an held call to active while another call is waiting Disconnect users in multiparty without accepting incoming call release all calls Example AT CHLD CHLD 0 1 1x 2 2x 3 4 6 7 8 OK AT CCWA 1 Enable call waiting OK atd9311234567 Originate a voice call OK OK conversation CCWA 358317654321 145 1 Bob Awaiting call alerts AT CHLD 2 Put first call on hold and answer the second call OK conversation H3 Family AT Commands User Manual Page 68 of 375 FIDCCON AT CHLD 3 Add the held call to the conversation OK MTPY conversation AT CHLD 22 Split Place the MO active call on hold MT call remains active OK AT CHLD 0 Release the held call OK NO CARRIER ath Release the active call OK NO CARRIER atd9311234567 Originate a voice call OK OK CCWA 055728386 129 1 0 Waiting call alerts AT CHLD 1 Release the active call accept the waiting call OK NO CARRIER Active 9311234567 was released OK Waiting 055728386 was answered 5 3 12 CCFC Call Forwarding Number and Conditions This command enables control of the call forwarding supplementar
315. tnn Sa cavbardeownd caaanedon sp nto lae 163 8 1 3 CPIN Enter PIN for Unlocking SIM or Enter PUK for Unblocking SIM cece 164 8 1 4 TPIN Query Number of Remaining SIM PIN PUK Entering Attempts cece 168 8 1 5 CPWD Change PaSSWOId cccccccccccsssscsscsseseeseescesesscssesecsecsecsssscesssscsscsecsecsecsececeseecseceecseeneeaes 169 8 1 6 CLGK Facility LOCK ac cnc di eiKanuiieghaveke RE a e aai iain 172 SIN GUWONK seat fic feo a E A fe esd cacpeddstatecg dest E E E E ds tccuselee teetvates 175 9 1 Network Commands sissien eiiie s aTa ON e 175 9 1 1 CSQ Signal Strengthens aani a A en n a TEER 175 9 1 2 CRLP Radio Link Protocol siosesiorisnseiiisnieiie oroi na ii 176 9 1 3 CREG Network Registration Status ccc ccscsccscsscsscseesecsessecscssceecsecsessecseesecseseceeesessaeaes 177 9 1 4 CGREG GPRS Network ReGistration ccc cece csccscesesscssesecseesecsesscescsecsscsecsecsecsecsecseesesaens 179 9 1 5 COPS Operator Selection ccc cccccccscsscsscseesecscesecscsscsecsscsecsecsesessesecssesecsacsecsseseeseacesesecseeaes 181 9 1 6 CPOL Preferred Operators cccccsccsccscsecsscseesecscesecscsceecsscsecsecseesecsecscessseceesecsseseesesaceseneesees 186 9 1 7 CBAND Change Radio Band cccccssssesssseseesescsseecseeseseeseseeseseeeeseeecaeeecsesseseeseseeseeeeseeeesseeees 189 9 1 8 CUBAND Change 3G Radio Band cccccccsccsecscescesesscsecsecseesecseescesesecseesecsscseesessceseseesees 191 9 1 9 KREG C
316. ts are used and text mode where the body of the message and its headers are given as separate parameters Command Syntax Response Action Remarks Set CMG OK The Set command sets the F lt mo or message format to use de gt CMS ERROR lt err gt Reay PENIG Peele snide The Read command displays the pi OK current message format Test CMG CMGF list of supported mode gt s The Test command lists all the F 7 OK supported message formats The following table shows the CMGF parameters lt Parameter gt Description lt mode gt Message format 0 PDU mode default 1 Text mode Example AT CMGF 1 OK H3 Family AT Commands User Manual Page 123 of 375 FIDCCON AT CMGF CMGF 1 OK AT CMGF CMGF 0 1 OK 7 1 4 CSCA Service Center Address This command enables to write read SCA to from SIM In SMS text mode SCA stored in SIM is added to any stored and sent SMS In SMS pdu mode SCA stored in SIM is added to stored SMS and send SMS only when SCA address length coded in PDU equals zero Command Syntax Response Action Remarks Set CSCA lt sc OK Sets service center address stored in a gt lt tosca gt ar SIM EF SMSp Short message service parameters lt tosca gt is optional CMS ERROR lt err gt f parameter When lt sca gt is prefixed with it indicates that lt tosca gt is set to 145 International number otherwi
317. uffers eeceseeseseseseeseseseeeseseeeecesesceceesecseneeessnseseeeeeeseeeaeeeeerseeeeeees 325 13 10 MIPRUDP Receive Data from UDP Protocol Stack eee eseeeseeseseseeeteeeeseseeeeeeeeseseeeeseeeseeeeeeeees 326 13 11 MIPRTCP Receive Data from TCP Protocol Stack ccceccesesseseeseseesesseseseescseeseseeseseneseeesseees 327 13 12 MIPSTAT Status REDOM Ei s i2 scsinesecs cdsssvesussezeatcndsn thecdedacaadesdset aa Solent tveetsaites salincstesisentetdancebedic 328 13 13 MIPCONF Configure Internal TCP IP Stack ccc ccessccsesccssescescsscescsecsscsecsecscessesceceecseenseaes 328 13 14 MPING Start Ping Execution ICMP Protocol cecccccccessseesesseseeeeceeeeeseeeesessesesseseneeeeeseeeesseeees 332 13 15 MPINGSTAT Status Update for MPING Execution ccccccccsecesssecescsecsscsecsecsesseesesseeseeesees 336 13 16 MSDNS Set DNS IP Address ee eceesessesesesesecesesesesesesseceecaesceseeseseseeseaeseseseeceecseaeeeaeeeseeeeeeaeers 338 13 17 MIPODM Open a Socket UDP or TCP in Online Data Mode ee ccceseseeereeeeeeeeeneneeeees 340 13 18 MIPXOFF Flow Control XOff ce eeeecceesceceseseeeseeecseseeeeeeeeseseeesceecseeeeesaeecseecneeaeecseeeeerseaeseeeeaeeeneeeees 343 13 19 MIPXON Flow Control XO eccceeseeseseeseeeseceseceeesesesceceessescecsecseaeeeseeeseaeaesseecaeeeeesseeeaeeeneeseeeatees 343 14 FIP COmmmanng gcse tei sgceese tech dledsesoud a aia SiS teas EAA aR EE a iE aa aA ES 344 14 1 FIP INTOdUC
318. unsolicited response with this lt status gt will be sent to DTE if socket connection was terminated for any reason This status essentially means that ping request execution was aborted 3 Flow Control OFF The unsolicited response with this lt status gt will H3 Family AT Commands User Manual Page 336 of 375 FIDCCON be sent to DTE if phone doesn t have enough memory to process sending an Echo Request message 4 Flow Control ON The unsolicited response with this lt status gt will be sent to DTE if phone has enough memory to send an Echo Request message after flow control was OFF lt Destination_IP gt Specifies the target machine computer for ping request which is identified by IP address 4 octets long in dotted decimal notation Each octet of IP address has valid value range of 0 to 255 lt SentMessages gt Specifies a total number of sent Echo Request messages lt ReceivedMessages gt Specifies a total number of received Echo Reply messages corresponding to Echo Request messages lt AvarageRT T gt Specifies average Round Trip Time RTT for this ping request This value will be reported if and only if lt ReceivedMessages gt value is greater than zero Calculation of this value comprises of accumulating all RTT values and dividing total accumulated RTT by lt ReceivedMessages gt value Only an integral part of a result will be reported and any digits of a frac
319. unvadeaaeunsdseaneaveasa sete cbaceyentsdeeiosaseeseeecpeaeeneae 81 5 4 1 CPAS Phone Activity Status ccc ccccccsscecsscssesecseeseesesscssesecssesecsscscesssecsecsecsecseesecseeseeesseees 81 5 4 2 CLCC List Current Calls eccececeesescesesesescseeeesescsesceescescaesceesacacseeesecacsesesecaeaceeeeeecacaeeeesneeateees 83 5 4 3 MCST Call Status M SSAGeS ec ccccccccccsscssesecsesseesesscssesecssesecsssscsesecsacsecsecsecsecesseecsececseensens 86 5 5 Call Advice of Charge COMMANAS ccccccccccesscscsssescsscsecsecseeseeseescssesscssesecsscseesesecacsecsacsecsecseesecaseseeessaeees 88 9 0 1 GAOC Advice of Charge s sc ciciiite nines detain eeedieseas de A E ee 88 5 5 2 CACM Accumulated Call MOLG Re i c ssicccssnasossbowssanevarnaupielenateuienescadeeaptacoasanatesubsestasioraeasderennqeaienece 90 5 5 3 CAMM Accumulated Call Meter Maximum ce ececeeseseeeseseseecscseseseseseseseseseeesescseseneaeeese 92 5 5 4 CPUC Price per Unit and Currency Table cceccccssssssesssseseeseseescececseseesesesseeeeseeeeseeeseseeaees 93 5 5 5 CR Service Reporting Control cccccccsccsscscesscscesccscssceecsecseesecsecsecsesecsesecseesecsseseeseseceaeseeseees 94 5 6 Supplementary Service Ssa ccccsccsscseesecscescescsscsecsecseesessesscssesecssesecsscseesesacsaesecsecsecsecsecsececsaseecsaceecseenseaes 96 5 6 1 CSSN Supplementary Service Notifications ecccccseseeseseeseeseeceeeeceeecseeseseeseseeseeeeeeeeeeees 96 5 6 2 CUSD Unstructured
320. urrent Network Registration Status ccccccsscsseseeseesccsesecssesecsseseesesecssesecsecaes 192 9 1 10 MCELL H3xx Cell D SCription cece cccessesesseseseeseseesescecseeeeseeceseseesesecsesesseesseeessesenseseeeeres 194 9 1 11 MCI H3xx Cell IMTOO M casaieeesdacicnonna dotesniedensendanstesoelacwsunsdes tpewscadceevacaisencies teed tuadeseslacn Genter okaee 198 9 1 12 GTRAT Selection of Radio Access TeChnOlog ccccccccsccccesscscssseecssceeeseceeseesesseeseseesses 201 10 Hardware Information cecccescecsessessseeseseseseseseeseecscsesesceecsesenesacsesesesesacscseseanacacseeesacecaeseeesacecaceeeetaeaeaeeeeanaceteeees 203 H3 Family AT Commands User Manual Page 8 of 375 FIDCCON 10 1 Uart P arameter COmmeaMG S a ccsuczescossecaviarssuesacavautavoasacgesquatas tactyaqneionuesaadansreveasaanaoasmara enaueentaceasnnteoieee 203 10 1 1 CBAUD Baud Rate Regulation ccccccssescssesesesseeeseseeseeeesesseseseescsessesessesenseenseeeneseeeetees 203 10 1 2 IPR Local Terminal Serial Port TRAC cs ceccovscucensssnosnmnescatscn teases easeansueasoren vedpeattansssemnansagstttannay 204 10 1 3 amp K RTS CTS Flow COMO 2 2 sa sseclaccasapatletgntadessseacretasanicceviveachsones ea idsebeuptiocaceisteottadeostiaeevteeas 207 10 1 4 IFC RTS CTS Flow Control ceeeeccseseessseceseseseesesescsesesceeeacscsesecseseneeecseaeeeeseecateceeeeeecaeeeeeeeees 208 10 1 5 amp C Circuit 109 BGM AVION reiini nie ere eee 209 10 1 6 amp D Circui
321. ve channels e The dess specified refers to all incoming messages and not only to mids specified in the same AT command Example Testing the modes supported AT CSCB CSCB 0 1 OK Reading the current mid and dcs lists AT CSCB CSCB 0 OK Adding channels 3 4 5 6 22 to mid list and languages 1 8 to dcs list AT CSCB 0 3 6 22 1 8 OK AT CSCB CSCB 0 3 6 22 1 8 OK H3 Family AT Commands User Manual Page 161 of 375 FIDCCON AT CSCB 1 4 6 1 OK AT CSCB CSCB 1 4 6 1 OK H3 Family AT Commands User Manual Page 162 of 375 FIDCCON 8 Access and security 8 1 1 A Repeat Last Command This command repeats the last command It is not necessary to press lt Enter gt after this command Note Only AT will not be repeated Command Syntax Response Action Execute Repeats last command Command AT will ignore Example AT amp D amp D 2 OK A amp D 2 OK 8 1 2 AT Check AT Communication This command only returns OK Command Syntax Response Action Execute AT OK Example AT OK Bs FIBOCOM 8 1 3 CPIN Enter PIN for Unlocking SIM or Enter PUK for Unblocking SIM This command unlocks the SIM card when the proper SIM PIN is provided and unblocks the SIM card when the proper SIM PUK is provided The SIM card is unlocked only once the provided pin is verified as the SIM PIN If the required PIN determined b
322. ving The mipopen command returns a MIPOPEN unsolicited event to indicate that the opration is success or not and if any error occurs after a socket was opened a usolictited event MIPSTAT would be send Note This command will return in 60 sec when DNS is error Command Syntax Response Action Remarks Set AT MIPOPEN lt Socket_ID gt lt Source_Port gt lt Remote _IP gt lt Remote_Port gt lt Prot ocol gt OK or MIPOPEN lt Socket_ID gt lt State gt lt Remot e_IP gt lt RemotePort gt The Set command returns lt Remote IP gt and lt Remote Port gt parameters only for sockets opened in H3 Family AT Commands User Manual Page 309 of 375 FIDCCON or MIPSTAT lt Socket_ID gt lt Status gt or ERROR lt err gt Listen mode Read AT MIPOPEN MIPOPEN lt Socket_ID gt for each socket that can be opened OK or MIPOPEN 0 OK if there are no free sockets The Read command returns the numbers of the sockets that can be opened Test AT MIPOPEN MIPOPEN list of supported lt socket_ID gt s list of supported lt source_port gt s list of supported lt Destination_IP gt s list of lt destination_port gt s list of supported lt protocol gt s OK Example AT MIPOPEN MIPOPEN 1 2 3 4 OK AT MIPOPEN H3 Family AT Commands User Manual All sockets closed Page 3
323. wer up Note For H350 xxx 10 H380 this command is not supported Command Syntax Response Action Set MSTART lt at start gt lt sim ready gt OK or ERROR Read MSTART MSTART lt at start gt lt sim ready gt OK Test MSTART MSTART 0 1 0 1 OK H3 Family AT Commands User Manual Page 221 of 375 FIDCCON The following table shows the MSTART parameters lt Parameter gt Description lt at start gt 0 Do not output AT command ready from UART 1 Output AT command ready from UART default value lt sim ready gt 0 Do not output SIM READY after SIM init OK 1 Output SIM READY after SIM init OK default value Notes AT command ready can not output from USB port even if set to 1 SIM READY can output from UART and USB port according to setting Example AT MSTART MSTART 0 1 0 1 OK AT MSTART 1 1 OK AT MSTART MSTART 1 1 OK 10 2 8 MSMPD Enable Disable SIM card hot plug This command can Enable Disable SIM card hot plug feature The default status is disable this feature The parameter will be saved in NVM and can restore at power cycle Command Syntax Response Action Remarks Set AT MSMPD lt status gt OK Enable Dlasble SIM card hot Or plug CME ERROR lt err gt Read AT MSMPD MSMPD lt status gt Read the current status OK H3 Family AT Commands User Manual
324. wing table shows lt DCE_by_DTE gt and lt DTE_by_DCE gt parameters Read AT IFC lt Parameter gt Description lt DCE_by_DTE gt 0 None 2 Circuit 133 RTS lt DTE_by_DCE gt 0 None 2 Circuit 106 CTS Example AT IFC IFC 0 0 OK AT IFC 2 2 OK H3 Family AT Commands User Manual Page 208 of 375 FiIDCCON 10 1 5 amp C Circuit 109 Behavior This parameter determines how the state of the DCD line relates to the detection of the received line signal from the distant end Changing the parameters will take effect immediately in both the command and online command states The DCD line is an output line that indicates the following In Circuit Switch Data mode an active low indicates that a valid carrier data signal was detected by H3xx CONNECT message is received and inactive high indicates idle The AT amp C command always puts the DCD command ON when set to 0 If the AT amp C command is set to 1 then the escape command sets the DCD signal to an inactive state and the ATO command is set to active AT amp C set to 2 sets the DCD signal OFF In GPRS mode the DCD line indicates the PDP context status PDP context active sets the DCD to active low PDP context inactive sets the DCD to inactive high DCD is activated only when the PDP context is achieved DCD is de activated when the PDP context is off In Local Link mode the DCD line indicates the Local Link data status
325. work while having their handsets display their own name as the network operator Testing the enhanced ONS feature requires a SIM ONS SIM card Command Syntax Response Action Remarks Set AT COPS OK The Set command can force an attempt to select lt mo ere and register a specific GSM network operator The lt mode gt selects whether this is done de gt lt form CME ERROR at gt automatically by the H3xx or whether the lt err gt selection is forced to an operator lt oper gt given lt oper gt lt in format lt format gt If the selected operator is AcT gt l l not available no other operator is selected except when the lt mode gt is set to 4 lt mode gt 2 forces an attempt to deregister from the network lt mode gt 3 sets the operator format to all further Read commands COPS as well The selected mode applies to future network registrations for example once you deregister from the network the H3xx remains unregistered until you select lt mode gt 0 lt mode gt 1 or lt mode gt 4 Read AT COPS COPS The Read command returns the current mode lt mode gt lt format and the currently selected operator gt lt oper gt lt AcT gt OK Or CME ERROR lt err gt Test AT COPS COPS list of The Test command returns a list of quadruplets H3 Family AT Commands User Manual Page 182 of 375 FIDCCON supported lt stat gt long alpha nume
326. works are selected alll Read AT CPOL CPOL H3 Family AT Commands User Manual Page 186 of 375 FIDCCON or CME ERROR lt err gt Test AT CPOL CPOL list of The Test command displays the supported lt index gt s list entire index range supported by of supported lt format gt s the SIM OK or CME ERROR lt err gt Index range is SIM dependent The following table shows the CPOL parameters lt Parameter gt Description lt indexn gt Order number of network operator in the SIM preferred operator list lt format gt Defines the lt oper gt format O0 Long alphanumeric format up to 16 characters default 1 Short alphanumeric format up to 8 characters 2 Numeric Name of the network operator string type lt format gt indicates if the format is alphanumeric or numeric lt oper gt see COPS GSM access technology 0 access technology not selected lt GSM_AcTn gt 1 access technology selected lt GSM_ Compact _AcTn GSM compact access technology gt 0 access technology not selected H3 Family AT Commands User Manual Page 187 of 375 FIDCCON 1 access technology selected UTRA access technology 0 access technology not selected lt UTRA_AcTn gt 1 access technology selected Note1 e If lt index gt is given but lt oper gt is left out entry is deleted e If lt oper gt is given but lt i
327. y service Registration erasure activation deactivation and status query are supported Command Syntax Response Action Remarks Set CCFC lt reason gt If the command succeeds lt mode gt lt numbe CCFC a a ei lt status gt lt class gt lt number gt lt type el SUn aera eee gt lt subaddr gt lt satype gt lt time gt type gt l lt time gt lll lt CR gt lt LF gt CCFC lt status gt lt class gt lt number gt lt type J CCFC list of supported lt reason gt s gt lt subaddr gt lt satype gt lt time gt L The Set command instructs the H3xx which call forwarding settings to request from network The Set command in query mode interrogates the network about the subscriber current call forwarding status H3 Family AT Commands User Manual Page 69 of 375 FIDCCON Test CCFC CCFC lt reason gt The Test command OK returns lt reason gt values supported by the H3xx to the terminal The following table shows the CCFC parameters lt Parameter gt Description lt reason gt 0 Unconditional 1 Mobile busy 2 No reply 3 Not reachable 4 All call forwarding 5 All conditional call forwarding lt mode gt 0 Disable 1 Enable 2 Query status 3 Registration 4 Erasure lt number gt Calling line number The number format is specified by lt type gt lt type gt Type o
328. y the error code returned from the requested operation or the Read command is SIM PUK or SIM PUK2 the second pin is required This second pin lt newpin gt is used to replace the old pin in the SIM card When entering the pin a lt new pin gt is not required A SIM card related error is returned if an AT command operation is unsuccessful due to a SIM card problem The following table shows the SIM card errors Error Description 10 SIM not inserted SIM Card is not inserted 11 SIM PIN required SIM Card waiting for SIM PIN to be entered 12 SIM PUK required SIM PIN is blocked 13 SIM failure SIM Card is permanently blocked 17 SIM PIN2 required SIM Card is waiting for SIM PIN2 to be entered 18 SIM PUK2 required SIM PIN2 is blocked Command Syntax Response Action Remarks Set AT CPI OK The Set command sends the password to N lt puk an the H3xx that is necessary before it can gt be operated SIM PIN or SIM PUK If CME ERROR F r there is no PIN request pending no action lt err gt lt pin gt lt is taken towards the H3xx and an error message CME ERROR is returned to newpin gt the terminal The Set command issued gives the code SIM PIN or SIM PUK corresponding to H3 Family AT Commands User Manual Page 164 of 375 Bs FIBOCOM the error code required or returned as the result of the Read command For example if the
329. ytes are similarly coded as the ACMmax value in the SIM Range is from 00001 to FFFFFF 0 Disables ACMmax default lt passwd gt SIM PIN2 password H3 Family AT Commands User Manual Page 92 of 375 FIDCCON incorrect password is displayed Maximum string length is 8 characters If this value is exceeded the command terminates in an error If PIN2 is incorrect CME ERROR Example AT CAMM OK AT CAMM FFFFFF 2222 OK AT CAMM CAMM FFFFFF OK 5 5 4 CPUC Price per Unit and Currency Table This command sets the parameters of the Advice of Charge related price per unit and currency table found in the SIM file EFPUCT PUCT information is used to convert the home units used in CAOC CACM and CAMM into currency units Command Syntax Response Action Remarks Set CPUC OK The Set command sets the price per lt currency CME ERROR unit and the currency table SIM PIN2 gt lt ppu gt lt Zens is required The new value is retained passwd gt after a power cycle Read CPUC CPUC The Read command displays the lt currency gt lt ppu gt current price per unit and currency OK table Test CPUC OK The Test command indicates whether the CPUC command is functioning The following table shows the CPUC parameters lt Parameter gt Description lt currency gt Currency code character set 3 characters defined by CSCS com