Home
STR150®
Contents
1. OFL 4070 000 13 Dec 2002
2. gt STR150 OFL 4070 000 tace Wall Module with Display User s Manual MOUNTING CABLES CONNECTING Connecting STR150 to a TAC Xenta 100 Family Cables Controller STR150 TAC Xenta Controller 101 VF 102 ES 103 A or 104 A m fe Mode 11 Data 12 Wiring Cable type ccccceeeeeeeeeees Twisted pair unshielded Cable size c ccceceeeseeeeeeeees Min 0 7 mm 19 AWG Distance erincsaneitinectierertiennoruieitainimatis Max 30 m 100 Ft To avoid base plate deformation be careful when ATTACHING REMOVING THE FRONT tightening the mounting screws Note that the enclosed screws are mainly intended for the US The front panel is and Australian markets attached to the base plate using four clamps two at the top of the front REMOVING THE CORE panel and two at the bottom The core panel is attached to the base plate using two hinges Remove the core panel by pushing the bottom of the core panel upwards then unhinging the core panel from the base plate When removing the front panel use a screwdriver or similar and push gently to unhook the clamps at the top or bottom of the front panel NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits ar
3. e designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help OFL 4070 000 13 Dec 2002 English 1 2 USER INTERFACE Adjusting the Room Temperature The increase button increases the temperature setpoint in steps of 0 1 or 0 5 C 0 2 or 1 0 F The decrease button decreases the temperature setpoint in steps of 0 1 or 0 5 C 0 2 or 1 0 F Changing to Occupied Mode The bypass button is used to change from standby economy or unoccupied mode to comfort mode When entering comfort mode the symbol on the display shows a steady light When the bypass time expires the symbol returns to its previo
4. us status again provided that the feedback mode is connected Otherwise the symbol returns to the Off status after two hours Adjusting the Fan Speed By pushing the button again it is possible to circle between the modes The fan symbol resumes a steady light after five seconds confirming the chosen mode The fan button is used to override the automatic fan control The different fan modes are represented by the fan group symbol on the display When the fan button is pushed the fan symbol on the display starts to flash indicating that the mode can be changed Fan Speed Symbols On Off Fan Two Speed Fan Three Speed Fan Auto Auto Auto as AUTO as AUTO oe AUTO Off Off Off On Fan Speed 1 Fan Speed 1 ELE EL ae LLL BS LLL Fans Speed 2 Fan Speed 2 A EET Be TTT Fan Speed 3 Ka pooginogoggg CONFIGURATION Enter Configuration Mode Push the fan and bypass buttons simultaneously for 2 seconds to enter PO In PO hold down the bypass button and push the fan button three times R The wrench symbol is lit when the STR150 is in configuration mode Exit Configuration Mode Push the fan and man button for 2 seconds The timeout will exit configuration mode if idle Configuration Options Parameter Value Range Default value PO Software Version P1 C or F temperature display 1 C 2 F P2 Reference temperature Reftemp 15 30 C 60 90 F P3 Setpoint or room temp as default 1 Setpt 2 Room P3 Timeo
5. ut 5 90 seconds P5 Fan settings O No fan 1 On Off fan 2 Two speed fan 3 Three speed fan P6 Room temperature and setpoint 0 1 or 0 5 C display resolution 0 2 or 1 0 F P7 Max adjustable setpoint span above or Q 5 C below Reftemp P2 0 10 F P8 Bypass button and occupancy indication 1 Symbol on off When 2 no bypass command is sent to the controller or flashing 2 Symbol always off Selecting Parameters and Values In configuration mode the two digits farthest to the left on the display show the parameters while the two digits farthest to the right shows the value 1 C 22 C 72 F 1 Setpt 10 seconds 3 Three speed fan 0 5 C 0 2 F 3 or 6 F Default 1 o0n off or flashing Trademarks and registered trademarks are the property of their respective owners TAC Vista TAC Menta TAC Xenta and Talking Buildings are registered trademarks of TAC AB LonMark and LonWork are registered trademarks of the Echelon Corporation Press the fan button repeatedly to select different parameters Change the value by pressing the increase or decrease buttons Note that PO is also used for display test Press the increase button when PO is displayed to show all symbols in the display Press the decrease button when PO is displayed to turn off all symbols in the display Windows is a registered trademark of Microsoft www tac global com 2 2 English
Download Pdf Manuals
Related Search
STR150 str1508c str15080-y
Related Contents
Delta UPS - Amplon Family Anexo - Capital Refrigeração VL024DX Manual rev1 こちら 120T Shortform Operating Instructions Notice d`utilisation 試薬添付文書 霧縄)ススプリンクラー取扱説明書 los proyectos hacen los objetos eternos, las modas los 2014 - Honda Motorcycles Copyright © All rights reserved.
Failed to retrieve file