1. USER MANUAL www kovan ba Room temperature controller with weekly programme USER MANUAL Q gt z z gt USER MANUAL USER MANUAL www kovan ba 1 Introduction Dear Customer Thank you for purchasing this product This product meets the requirements of current statutory European and national guidelines To maintain this status and to ensure safe operation you as the user must observe these operating instructions These operating instructions are part of this product They contain important information concerning operation and handling Please bear this in mind in case you pass on the product to any third party Therefore retain these operating instructions for reference In case of any technical questions contact or consult Tel 00387 62 255 398 E mail servis kovan ba Mon Sat 7 00 16 00 USER MANUAL www kovan ba 2 Intended use The product measures the current room temperature via an internal temperature sensor Depending on an intended set temperature the integrated switching output is activated The heating and cooling devices can be controlled by it A contact sensitive LC display is used to operate all functions The product is supplied with power by two AA mignon type batteries Observe the safety notes and all other information in these instructions This product complies with the applicable statutory national and European specifications All company names an
2. Wake up function Keep the LO button pressed for 5 seconds AL appears at the top of the display Press the button The pre set alarm wake up time appears e g 0 00 together with the symbol USER MANUAL www kovan ba Select the day block on which the wake up sounds is to be output with the buttons and Press the LO button The hours of the alarm wake up time flash Set the hours with the and 6 buttons Press the button The minutes of the alarm wake up time flash Set the minutes with the and buttons Confirm the setting with If you don t press anything for longer than 15 seconds the device will leave the programming mode To deactivate the alarm wake up function do as follows e Press and hold the button for 5 seconds e Press the button e Press the button 15 Key lock To activate the key lock keep the button pressed for approx 5 seconds until all button symbols disappear from the display USER MANUAL www kovan ba To deactivate the key lock again keep the button pressed again for approx 5 seconds until all button symbols appear again on the display 16 Notes on batteries When the afi symbol shows up on the display you need to exchange the batteries Please observe the correct polarity positive and negative 17 Maintenance and cleaning To clean the outside of the room thermostat a dry soft and clean cloth is sufficient Do not press too hard on the
3. d product names are trademarks of their respective owners All rights reserved 3 Explanation of Symbols This lightning symbol is used when your health is at risk e g from electric shock An exclamation mark in a triangle indicates important instructions in this operating manual which must be observed USER MANUAL www kovan ba The hand symbol indicates special information and advice on operation of the device 4 Safety information In case of damage caused by non compliance with these safety instructions the warranty guarantee will become void We do not assume any responsibility for consequential damage We do not assume any liability for damage to property of personal injury caused by improper use or the failure to observe the safety instructions In such cases the warranty guarantee is void The device is not a toy Devices operated using the mains voltage must be kept out of the reach of children Particular care must therefore be exercised if children are around The product should only be used in closed dry indoor areas it must not become damp or wet There is the risk of a fatal electric shock Do not leave packaging material unattended It may become a dangerous toy for children Do not use the product inside of rooms or in bad ambient conditions where flammable gases vapours or explosive dust may be or are present There is a danger of explosion USER MANUAL www kovan ba In commercial and ind
4. display as this may cause scratch marks or lead to faulty displays or even broken screen Dust on the casing can easily be removed with a clean brush and a vacuum cleaner Never use any agressive cleaning agents or other chemical solvents since this may damage the surface of the casing or even impair operation USER MANUAL www kovan ba 18 Disposal of batteries and rechargeable batteries You as the end user are required by law Battery Ordinance to return all used batteries rechargeable batteries Disposing of them in the household waste is prohibited Batteries rechargeable batteries that include hazardous substances are labelled with these icons to indicate that disposal in domestic waste is forbidden The descriptions for the respective heavy metal are Cd cadmium Hg mercury Pb lead the names are indicated on the battery rechargeable batteries free of charge at the official collection points of your community on our stores or wherever batteries rechargeable batteries are sold Sa ovim e te ispuniti svoje gra anske du nosti u za titi okoline USER MANUAL www kovan ba 19 Technical data Operating voltage 3 V DC 2 pcs AA Mignon batteries Operating temperature 5 C do 37 C Display range 3 C do 37 C below 3 C the display shows LO above 37 C the display shows HI Switching hysteresis 0 2 C Dimensions W x H x D ca 130 x 88 x 38 mm
5. e for economic operation For these settings use chapter 12 o Settin the control temperatures Za memorisanje pode enja pritisnite tipku Example Les gt a ERERRERERERER EEE ERERENENEE BER BRR REPRE PRR 00 06 12 00 00 06 00 Night control temperature 18 C 06 00 23 00 Daily control temperature 23 C 23 00 00 00 Night control temperature 18 C Follow the next steps to program the room thermostat like shown above 1 Hold down the 3 button for 5 seconds USER MANUAL www kovan ba Set the day with the and buttons Press the O button On the display flashes 0 00 Press the button Press the button until 6 00 is displayed Press the G button Press the button until 23 00 is displayed Press the button 10 Press the button until 0 00 is displayed 11 Press the button If you don t press anything for longer than 15 seconds the device will SS EN a a eS leave the programming mode Program 5 2 In this regime the program is set up in two blocks The first block for Monday Friday and the second for Saturday Sunday Hold down the E button for 5 seconds A weekday or one of the day blocks starts flashing Select the dayblock 1 5 for Monday Fridaj 6 7 for Saturday Sunday by pressing the and ee buttons Press the button USER MANUAL www kovan ba Now the time display 0 00 and the first point column in the bar display for the temperature cu
6. he button The minutes of the current time flash Set the minutes with the and buttons Press to store the settings The device leaves the setting mode Selecting Heating and Cooling Modes Press the button The year flashes Press 3 repeatedly to switch between heating mode display HEAT and cooling mode display COOL Briefly press to confirm the settings The device leaves the setting mode USER MANUAL www kovan ba Heating mode The relay is activated if the measured temperature falls below a set ii temperature threshold The display shows Cooling mode The relay is activated if the measured temperature rises above a set temperature threshold The display shows 10 Programming setup There are three different programs Daily program In this program the regime is set up day by day Hold down the G button for 5 seconds A weekday or one of the day blocks starts flashing 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday 7 Sunday Select the desired weekday or day block with the and a buttons ra Confirm the selection with Now the time display 0 00 and the first point column in the bar display for the temperature curve flash USER MANUAL www kovan ba Now set the desired period for the selected temperature value with and in steps of 30 minutes Normal temperature value Temperature value for night reduction Temperature valu
7. he whole weed 11 Manual temperature setting In manual mode amp is displayed If you want to set up a duration time a ICT is displayed Every confirmation is done by pressing the button By pressing button again the room thermostat returns to normal regime 11 1 Manual temperature setting Set the desired temperature manually with and Es is displayed Press the button once To go back to normal regime press the button again USER MANUAL www kovan ba 11 2 Retain manual temperature To set up a retain manual temperature do the following steps Set up the desired temperatures with the and buttons Press the button once o Use and to set the number of hours for which the manual temperature setting is to apply you can set 1 24 hours o Confirm the setting with or Press the LO button again to set the nuber of days o Use and to set the number of days for which the manual temperature setting is to apply you can set 1 99 days o Confirm the setting with the button or Press the O button to hold the manual temperature without limitation If you want to quit the manual mode press the button 12 Temperature settings Three control temperatures are available for temperature monitoring of the room thermostat e GE Normal temperature value USER MANUAL www kovan ba Temperature value for energy saving Temperature value for night reduction Proceed as follows to se
8. rmostat o Connect contact No 18 of the boiler electronics to NO on the room thermostat Connecting the reciever of the wireless room thermostat o Connect the brown wire to contact No 19 of the boiler electronics Connect the blue wire to contact No 21 of the boiler electronics o Connect the green yellow wire to contact No 18 of the boiler electronics Replace the protective cover 3 again only wire thermostat Secure the protective cover with the screw 2 only wire thermostat Use the fastening apertures 4 to srew the room thermostat to the wall Close the casing and retighten the screw 1 turned out in the beginning USER MANUAL www kovan ba 6 Factory settings The room thermostat is set up with the following factory settings Monday Sunday Duration of daily regimen 6 00 23 00 Duration of night regimen 23 00 6 00 Daily temperature 23 C Night temperature 18 C 7 Markings on the display Set Current day temperature Current time or date USER MANUAL www kovan ba 8 Setting the time Pode avanje vremena i datuma se vr i na slijede i na in Press the LO button The year flashes Set it with the buttons and Press the button The month flashes Set the month with the and buttons Press the button The date flashes Set the date with the and buttons Press the button The hours of the current time flash Set the hours with the and buttons Press t
9. rve flash Now set the desired period for the selected temperature value with and in steps of 30 minutes Normal temperature value Temperature value for night reduction Temperature value for economic operation For these settings use chapter 12 Settin the control temperatures Example Monday Friday 00 00 06 00 Night control temperature 18 C 06 00 09 00 Daily control temperature 23 C 09 00 17 00 Economic control temperature 15 C 17 00 23 00 Daily control temperature 23 C 23 00 00 00 Night control temperature 18 C USER MANUAL www kovan ba Follow the next steps to program the room thermostat like shown above Press and hold the CE button for 5 seconds Set the dayblock 1 2 3 4 5 with the and buttons Press the button On the display flashes 0 00 Press the button Press the button until 6 00 is displayed Press the GE button Press the btuuon until 9 00 is displayed Press the button Press the button until 17 00 is displayed Press the CE button Press the button until 23 00 is displayed Press the DD button Press the button until 0 00 is displayed Press the button 1 2 3 4 5 6 7 8 g e e e RP RP H U A U N Be O If you don t press anything for longer than 15 seconds the device will leave the programming mode USER MANUAL www kovan ba Weekly program In this program one regime is set up for t
10. t the 3 temperatures e Press the button and the symbol GE flashes o To set the normal temperature value use the and buttons Press the button and the symbol flashes o Toset the temperature value for energy saving use the and buttons Press the button and the symbol flashes o Toset the temperature value for night temperature reduction use the and buttons Briefly press the button to confirm the settings The device leaves the setting mode If you don t press anything for longer than 15 seconds the device will leave the programming mode 13 Selecting mode of operation Press 38 repeatedly to either activate automatic operation or set the room thermostat to maintain one of the temperature values USER MANUAL www kovan ba Symbol 3 is displayed above the bar display normal temperature value is active Symbol is displayed above the bar display temperature value for economic operation is active Symbol is displayed above the bar display temperature value for night temperature reduction is active The symbol is displayed above the bar display as well as the symbol for the current temperature value The room thermostat now controls the room temperature depending on the temperature curve programmed by you The Ke symbol appears to the right of the time temperature display frost protection this function is only available if the room thermostat is in heating mode 14 Alarm
11. ustrial facilities the regulations for the prevention of accidents as laid down by the proffessional trade association for electrical equipment and devices need to be observed 5 Installation Mount the room thermostat on stable surfaces only Use the screws or dowels appropriate for the surface The product must be operated stationarily installed The room thermostat must be voltage free during installation To ensure that the room thermostat works properly do not mount it close to radiators electrical devices or windows Also avoid direct sunlight Screw for casing closure Screw for protective cover Protective cover Apertures for wall mounting USER MANUAL www kovan ba Opening for connection cable Screw terminal NC COM NO Battery compartment Catches in the upper part of the casing Reset button For installation do the following steps Unscrew the screw 1 on the right side Remove the upper casing Insert two type AA mignon batteries in the battery compartment 7 with the correct polarity IN CASE OF DAMAGE CAUSED BY NON COMPLIANCE WITH THESE SAFETY USER MANUAL www kovan ba INSTRUCTIONS THE WARRANTY GUARANTEE WILL BECOME VOID Remove the screw 2 only wire thermostat Remove the protective cover 3 only wire thermostat Connect the power supply to the screw terminals 6 only wire thermostat o Connect contact No 19 of the boiler electronics to COM on the room the
Download Pdf Manuals
Related Search
Related Contents
Reference Series Hamilton Beach Panini Press Gourmet Sandwich Maker 25450 User's Manual OFFSET DOUBLE BOWL SINK Workswell Thermal Vision – User Manual 9 - BMW Motorrad Samsung Digimax GX-1L User's Manual Copyright © All rights reserved.
Failed to retrieve file