Home
MELSECNET/H Network Module User`s Manual (Hardware)
Contents
1. 5 5 dB or less Conversion cable 1m Adaptor Connection loss 1 dB max _ __ 7 SD oy Total cable loss 7 5 dB or less Optical module 1 Conversion cable CA type lt FC type AGE 1P CA FC1 5M A CA type lt ST type AGE 1P CA ST1 5M A CA type lt SMA type AGE 1P CA SMA1 5M A Purchased from Mitsubishi Electric Europe GmbH 3 Handling Use the programmable controller in the operating environment that meets the general specifications given in the user s manual of the CPU module Using the programmable controller in any other operating environment may cause an electric shock fire or malfunction or may damage or degrade the product While holding the module mounting lever at the bottom of module insert the module fixing tab into the fixing hole in the base unit Then secure the module using the module fixing hole as a support point Incorrect mounting may cause malfunctions a failure or a drop of the module In an environment of frequent vibrations secure the module with the screw Tighten the screw within the specified torque range If the screw is too loose it may cause a drop of the module a short circuit or malfunctions If too tight it may damage the screw and or the module resulting in a drop of the module a short circuit or malfunctions Completely turn off the externally supplied power used in the system before mounting or removing the
2. 4 3 Left side STATION NO llje 2 L QJ71LP21GE Number Name Socian Tone Number Name Sesion eon in this in this RESET switch 1 Connector amie in this chapter za RS 232 connector Station number in this setting switches S 1 To reset the module press the RESET switch for 1 second or more Pressing it less than 1 second may result in improper resetting In such a case reset it again 1 Display contents for LEDs QJ71LP21GE RUN On Operating normally Cea ah Off Watchdog timer error occurred hardware fault SDO ORD T PASS On Executing baton pass RECREERE Flicker Executing test ci Baton pass not yet executed host is disconnecting Or pata not yet verema Off Data not yet transmitting On Setting error occurred Flicker e Error detected by a test e The mode setting switch or the station number setting switch was changed during operation Off No setting error On Operating as a control station sub control station remote master station or remote sub master station Off Operating as a normal station On Operating normally Flicker Flash ROM is being written or the device of the parameter is being tested Off In remote initialization watchdog timer error blown fuse error input output verification error Off Data link not yet executed E e Off Data not yet received Off No communication error 1 When the remote I O module is used i
3. hands dirt or dust should adhere to the core the transmission loss will increase causing a malfunction in the data link Also do not remove the cover from the module connector until an optical fiber cable is connected 4 When attaching or detaching the optical fiber cable to from the module hold the cable connector securely with the hands 5 Connect the cable connector and module connector securely until you hear a click sound 6 Completely turn off the externally supplied power used in the system when connecting or disconnecting the cable 7 Connect the optical fiber cables as shown below a QJ71LP21GE QJ71LP21GE QJ71LP21GE QJ71LP21GE QJ71LP21GE b QU71LP21GE QJ72LP25GE QJ71LP21GE QJ72LP25GE QJ72LP25GE Optical module Optical fiber cable 6 External Dimensions 1 QJ71LP21GE QJ71LP21GE RUN MNG T PASS D LINK 98 3 86 27 4 1 08 90 3 54 4 1 Please contact Mitsubishi Electric Europe GmbH for detail Unit mm in 2 QU72LP25GE QJ72LP25GE RUN REM T PASS Ko E mM O STATION NO x10 90 3 54 2 27 4 1 08 Unit mm in 2 Please contact your nearest Mitsubishi Electric System Service Corporation for detail Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits cau
4. module Failure to do so may damage the product Modules of function version D or later can be replaced online on the remote I O station Nevertheless there are some restrictions on the online replaceable modules and replacement procedures are predetermined for each module For details refer to the Q Corresponding MELSECNET H Network System Reference Manual Remote I O network Do not directly touch the conducting parts and electronic parts of the module This may cause the module to malfunction or fail Before handling the module touch a grounded metal object to discharge the static electricity from the human body Failure to do so may cause malfunction or failure of the module 3 1 Handling Precautions 1 Since the module case is made of resin do not drop it or subject it to strong impact 2 The module can easily be secured to the base unit using the hooks located at the top of the module In places where there are frequent vibrations however it is recommended to fix the module with the module fixing screws In this case tighten the module fixing screws within the following clamping torque range Module fixing screws M3 Tightening torque range is 0 36 to 0 48 N m 4 Part Identification Names QJ71LP21GE QJ72LP25GE QJ71LP21GE RUN MNG T PASS D LINK 1 SD RD ERR LERR STATION NO QJTALPZGE EM T Pass D LINK SD RD L ERR ERR a 2S le OUR 2 MODE 4
5. 120 0808 Tel 55 1 1 5908 8331 Taiwan Setsuyo Enterprise Co Ltd Germany Mitsubishi Electric Europe B V German 6F No 105 Wu Kung 3rd Rd Wu Ku Branch Hsiang Taipei Hsine Taiwan Gothaer Strasse 8 D 40880 Ratingen Tel 886 2 2299 2499 GERMANY Korea Mitsubishi Electric Automation Korea Tel 49 2102 486 0 Co Ltd U K Mitsubishi Electric Europe B V UK 1480 6 Gayang dong Gangseo ku Branch Seoul 157 200 Korea Travellers Lane Hatfield Hertfordshire Tel 82 2 3660 9552 AL10 8XB U K Singapore Mitsubishi Electric Asia Pte Ltd Tel 44 1707 276100 307 Alexandra Road 05 01 02 woh Mitsubishi Electric Buildin Italy Mitsubishi Electric Europe B V Italian Singapore 159943 9 prenent Tel 65 6470 2460 Centro Dir Colleoni Pal Perseo Ingr 2 Thailand Mitsubishi Electric Automation Thailand Via Paracelso 12 l 20041 Agrate Brianza Co Ltd Milano Italy Bang Chan Industrial Estate No 111 Tel 39 039 60531 Moo 4 Serithai Rd T Kannayao Spain Mitsubishi Electric Europe B V Spanish A Kannayao Bangkok 10230 Thailand Branch Tel 66 2 517 1326 Carretera de Rubi 76 80 Indonesia P T Autoteknindo Sumber Makmur E 08190 Sant Cugat del Valles Muara Karang Selatan Block A Utara Barcelona Spain No 1 Kav No 11 Kawasan Industri Tel 34 93 565 3131 Pergudangan Jakarta Utara 14440 _ France Mitsubishi Electric Europe B V French P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 a d des B ts F 92741 India M
6. MITSUBISHI MELSECNET H Network Module User s Manual Hardware QJ71LP21GE QJ72LP25GE Thank you for purchasing the Mitsubishi programmable controller MELSEC Q Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product WELSEC Q Mitsubishi 13JR34 Programmable Controller IB NA 0800183 E 0703 MEE 2001 MITSUBISHI ELECTRIC CORPORATION SAFETY PRECAUTIONS Always read these instructions before using this equipment Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly Precautionary notes in this manual cover only the installation of this product For precautions on designing and discarding this product refer to Safety Precautions in the MELSECNET H Reference Manual For safety precautions on the programmable controller system refer to the CPU User s Manual In this manual the safety instructions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause hazardous DANGER conditions resulting in death or severe injury NCAUTION Indicates that incorrect handling may cause hazardous conditions resulting in medium or slight personal injury or physical damage A m m m e e e e e cS e e e i e Note that the A CAUTION level may lead to a serious consequence according to the c
7. d by user 3 Applicable connector 2 core optical connector plug Arranged by user 3 Base unit installation position CPU slot 5 VDC current consumption 0 89A External dimensions 98 3 86 in H x 27 4 1 08 in W x 90 3 54 in D mm Weight 0 15 kg 1 The remote master station includes the multiplexed remote master station and multiplexed remote sub master station 2 On a multiplexed remote I O network one of 64 remote I O stations works as a multiplexed remote sub master station 3 Specialized skill and specific tools are required to connect the connector to the optical fiber cable the connector itself is a custom product Please contact your nearest Mitsubishi Electric Europe GmbH when purchasing these items For general specifications of the network module refer to the user s manual for the CPU that is to be used Maximum number of link points per network Maximum number of link points per station 2 2 Gl 62 5 125 optical fiber cable specifications 1 Applicable cable specifications e The specifications for the GI 62 5 125 cable are given below e If you prepare a GI 62 5 125 cable yourself it must comply with the specifications indicated below Fiber type GI graded index type multimode quartz glass Core diameter 62 5um Clad diameter 125um Transmission loss 3dB km or less Wave length 0 85um Transmission band 300 MHz km or more 2 Cable loss Conversion cable 1m 1 QJ71LP21GE QJ72LP25GE
8. er cable the connector itself is a custom product Please contact your nearest Mitsubishi Electric Europe GmbH when purchasing these items 2 QU72LP25GE Specifications LX LY 8192 points 16384 points Remote master station to Remote submaster station Remote I O station 8192 points Remote submaster station Remote I O station to Remote master station 8192 points 16384 points Remote master station to Remote submaster station Remote I O station 8192 points Remote submaster station Remote I O station to Remote master station 8192 points e Remote master station gt Remote I O station 1 LY LB 8 LW x 2 lt 1600 bytes e Remote I O station Remote master station 1 LX LB 8 LW x 2 lt 1600 bytes e Multiplexed remote master station lt Multiplexed remote sub master station Y LB 8 LW x 2 lt 2000 bytes Maximum number of I O points X Y lt 4096 points per remote I O station When X Y number overlaps either of then becomes effective Communication speed 10Mbps ommunication method Token ring Synchronous method Frame synchronous method Transmission path format Duplex loop Maximum number of networks 239 Maximum number of groups 32 Number of stations per network 65 stations Remote master station 1 Remote I O station 64 2 Overall distance 30 km 98430 ft Distance between stations GI 62 5 125 optical cable 2km 6562 ft Connection cable Optical fiber cable Arrange
9. essung Systems Pvt Ltd aa A ane Electronic Sadan NO III Unit No15 M 1 D C Bhosari Pune 411026 India TEL 33 1 5568 5568 Tel 91 20 2712 3130 South Africa Circuit Breaker Industries Ltd Australia Mitsubishi Electric Australia Pty Ltd Private Bag 2016 ZA 1600 Isando 348 Victoria Road Rydalmere South Africa N S W 2116 Australia Tel 27 11 928 2000 Tel 61 2 9684 7777 a MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN Specifications subject to change without notice Printed in Japan on recycled paper
10. ictions on the online replaceable modules and replacement procedures are predetermined for each module For details refer to the Q Corresponding MELSECNET H Network System Reference Manual Remote I O network Do not directly touch the conducting parts and electronic parts of the module This may cause the module to malfunction or fail Before handling the module touch a grounded metal object to discharge the static electricity from the human body Failure to do so may cause malfunction or failure of the module WIRING PRECAUTIONS Completely turn off the externally supplied power used in the system when installing or placing wiring Failure to do so may cause electric shocks or damage the product Be careful not to let foreign objects such as dust and wire chips get inside the module They may cause a fire mechanical breakdown or malfunction The top surface of the module is covered with a protective film to prevent foreign objects such as wire chips from entering the module during wiring work Do not remove this film until all the wiring work is complete Before operating the system be sure to remove the film to release the heat Make sure to place the communication and power cables into a duct or fasten them using a clamp Failure to do so may damage the module or cables by pulling a dangling cable inadvertently or cause the module to malfunction due to bad connection When disconnecting a communication cable do not
11. ina ran Setting at time name content ype Seng Tange of shipment Sets the PLC to PLC 0 On line operating network 1 Self loopback test 2 Internal self loopback Remote I O test network 3 Hardware test 4 to F Use prohibited 1 Control station normal station of PLC to PLC network or remote I O network when making to online with Mode setting switch remote master station and remote I O station is made the switch the same set MODE 3 Connector a IN OUT connector Connected with an optical fiber connector 1 QJ71LP21GE IN Forward loop receiving IN Reverse loop sending IN Reverse loop sending IN Forward loop receiving MODE gt OUT Forward loop sending OUT Reverse loop receiving 5 Wiring 5 1 Precautions for Laying Optical Fiber Cables 1 When optical fiber cable is connected there are restrictions for the bending radius of the cable For details check the specifications of the cable to be used 2 Please maintain the optical fiber cable permissible bending radius with a checking tool Enquiries for the checking tool for optical fiber cable bending radius maintenance are handled by Mitsubishi Electric Europe GmbH Please contact Mitsubishi Electric Europe GmbH for detail 3 When laying the optical fiber cable do not touch the fiber core of the cable connector or module connector or let dirt or dust collect on it If oil from the
12. ircumstances Always follow the instructions of both levels because they are important to personal safety Please store this manual in a safe place and make it accessible when required Always forward it to the end user INSTALLATION PRECAUTIONS Use the programmable controller in the operating environment that meets the general specifications given in the user s manual of the CPU module Using the programmable controller in any other operating environment may cause an electric shock fire or malfunction or may damage or degrade the product While holding the module mounting lever at the bottom of module insert the module fixing tab into the fixing hole in the base unit Then secure the module using the module fixing hole as a support point Incorrect mounting may cause malfunctions a failure or a drop of the module In an environment of frequent vibrations secure the module with the screw Tighten the screw within the specified torque range If the screw is too loose it may cause a drop of the module a short circuit or malfunctions If too tight it may damage the screw and or the module resulting in a drop of the module a short circuit or malfunctions Completely turn off the externally supplied power used in the system before mounting or removing the module Failure to do so may damage the product Modules of function version D or later can be replaced online on the remote I O station Nevertheless there are some restr
13. n the redundant power supply system the REM and ERR LEDs indicate the failure cause of the power supply module s as follows Power supply module REM LED ERR LED Input power supply OFF fuse blown intamaltaui QJ72LP25GE RUNO OREM T PASSO OD LINK SDO ORD ERR O OL ERR Only one module failed Input power supply OFF fuse blown Soro ay aie Internal fault When a remote I O module of function version C or earlier has been used the ERR LED remains OFF even if one or two power supply modules went down For failure of a power supply module check the LED on the power supply module If it is mounted on the extension base unit the status can be also checked by the power supply module s ERR contact Refer to the QCPU User s Manual Hardware Design Maintenance and Inspection for the LED specifications of the power supply module 2 Setting contents for each switch a Station ee setting switches QJ71LP21GE Le Setting Setting at time 10s unit gt x10 X Station Setsthe PLC to PLC 1 to 64 ore number station network Setting error for other is unit gt X1 oxy setting number than the above switches Remote I O 0 Remote master station Setting error for other than the above 2 QJ72LP25GE ae Setting Setting at time Station Sets the 1 to 64 Remote I O station number station Setting error for other than the above setting number switches b Mode setting switch Switch Setting T St
14. pull it by holding the cable part To disconnect the cable hold its connector that is plugged into the module Pulling the cable part with the cable still connected to the module may damage the module and or cable or cause malfunctions due to poor cable contact Install our programmable controller in a control panel for use Wire the main power supply to the power supply module installed in a control panel through a distribution terminal block Furthermore the wiring and replacement of a power supply module have to be performed by a maintenance worker who acquainted with shock protection For the wiring methods refer to QCPU User s Manual Hardware Design Maintenance and Inspection About the Manuals The following manuals are also related to this product In necessary order them by quoting the details in the tables below Related Manuals Manual name Manual No Model code Q corresponding MELSECNET H Network System Reference Manual PLC to PLC network 13JF92 Q corresponding MELSECNET H Network System Reference Manual Remote I O network 13JF96 For QnA Q4AR corresponding MELSECNET 10 Network IB 66690 System Reference Manual 13JF78 Compliance with the EMC Directive and the Low Voltage Directive When incorporating the Mitsubishi programmable controller into other industrial machinery or equipment and keeping compliance with the EMC and low voltage directives refer to Chapter 3 EMC Directive and Low Voltage Inst
15. ruction of the User s Manual Hardware for the CPU module used or the programmable controller CPU supplied with the base unit The CE logo is printed on the rating plate of the programmable controller indicating compliance with the EMC and low voltage directives For making this product compliant with the EMC and low voltage directives please refer to Section 3 1 3 Cable in Chapter 3 of the above mentioned user s manual 1 Overview This manual explains how to handle the MELSECNET H network module model numbers QJ71LP21GE and QJ72LP25GE hereinafter referred to as the network module After unpacking the network module confirm that any of the following products is enclosed Model number Quantity QJ71LP21GE Model QJ71LP21GE MELSECNET H network module optical loop type QJ72LP25Gg Model QJ72LP25GE MELSECNET H network module optical loop type 2 Performance Specifications 2 1 Performance specifications for the network module 1 QU71LP21GE Specifications Maximum number of link points 1 PLC to PLC network MELSECNET H Extended mode 1 mode 1 2 Remote I O network 16384 points Remote master station to Remote submaster station Remote I O station 8192 points Remote submaster station Remote I O station to Remote master station 8192 points 16384 points Remote master station to Remote submaster station Remote I O station 8192 points Remote submaster station Remote I O station to Remote mas
16. sed by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc Hong Kong Mitsubishi Electric Automation 500 Corporate Woods Parkway Vernon Hong Kong Ltd Hills IL 60061 U S A 10th Floor Manulife Tower 169 Electric Tel 1 847 478 2100 Road North Point Hong Kong Brazil MELCO TEC Rep Com e Assessoria Tel 852 2887 8870 China Mitsubishi Electric Automation Tecnica Ltda Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Shanghai Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Paraiso Sao Paulo SP Brazil f i Tel 86 21 6
17. ter station 8192 points e MELSECNET H mode MELSECNET 10 mode PLC to PLC LY LB 8 LW x 2 lt 2000 bytes 2 network e MELSECNET H Extended mode LY LB 8 LW x 2 lt 35840 bytes 2 Maximum e Remote master station gt Remote I O station 3 number of link LY LB 8 LW x 2 lt 1600 bytes a Remote I O e Remote I O station gt Remote master station 3 neork LX LB 8 LW x 2 lt 1600 bytes e Multiplexed remote master station lt Multiplexed remote sub master station LY LB 8 LW x 2 lt 2000 bytes 10Mbps Token ring Number of Boas 64 stations control station 1 normal station 63 network stations per Remote I O network 65 stations ioia master station 1 Remote I O station 64 4 Optical fiber cable a By user a 2 core optical connector plug Arranged by user 5 98 3 86 in H x 27 4 1 08 in W x 90 3 54 in D mm 0 11 kg 1 Mode selection is performed using network parameters 2 The number of LY points of the stations set in the I O master station is the sum total of the LY points for output to all stations within the block 3 The remote master station includes the multiplexed remote master station and multiplexed remote sub master station 4 On a multiplexed remote I O network one of 64 remote I O stations works as a multiplexed remote sub master station 5 Specialized skill and specific tools are required to connect the connector to the optical fib
Download Pdf Manuals