Home

General Settings (CAL 1)

image

Contents

1. bbL 0 Disable Hi alarm sound bbL 1 Set Hi alarm sound as continual short beeps bbL 2 Set Hi alarm sound as continual long beeps Print Settings CAL 2 c mE Press cR toggle among the options Use the numeric keys to input data and press to save your settings Print MEE A Pr I um Set the print format to default settings Pr LP50 Set the print format to LP 50 printer 2 Printout setting P PrESS Press M to print single weighing result Press C in MR mode to print accumulated weighing result and total accumulation P StAb 1 Print weighing result Net wt Pc wt Pc count when the scale is stable and weight gt 0 Pressing M and MR do not print P StAb 2 Print Net wt when the scale is stable and weight gt 0 Pressing M and MR do not print P ALL 1 Press M to print single weighing result Press C in MR mode to print accumulated weighing result and total accumulation Print weighing result Net wt Pc wt Pc count when the scale is stable and weight gt 0 P ALL 2 Press M to print single weighing result Press C in MR mode to print accumulated weighing result and total accumulation Print Net wt when the scale is stable and weight gt 0 P Count Continuous printing weight data Usually used for sending weight data to PC Print function disabled 3 Baud Rate br2400 Set the baud rate to 2400 br4800 Set the baud rate to 4800 br9600 Set the baud rate to 9
2. 600 4 Parity Setting PA 7 E 1 Set the parity to 7 E 1 PA 7 0 1 Set the parity to 7 0 1 PA 7 n 2 Set the parity to 7 n 2 Set the parity to 8 n 1 PA 8 E 1 Set the parity to 8 E 1 PA 8 o 1 Set the parity to 8 o 1 Calibration Procedure CAL 3 Please remove the JP3 jumper before you start the calibration process s Cc In Calibration menu press to toggle among the menu options And press V to confirm 1 SEL maximum capacity LoAd Set maximum capacity as 6 kg e LoAd Set maximum capacity as 15 kg oo mmm LoAd Set maximum capacity as 30 kg tat SSma 2 A0 AO O off Zero tracking function is disabled A0 1 on Zero tracking function is activated 3 Zero Point Calibration The right window shows AD Value of Zero weight Wait until n the AD value becomes stable press v to confirm Pnt O XXXXXX 4 Setup calibration weight Pnt CAL XXXXXX Put 1 3 or 2 3 or 3 3 of full load on the weighing pan The right window shows AD Value of the load Wait until the AD value becomes stable press to confirm n Pnt CAL 1 2 30000 The right window will cycle display the 1 3 2 3 3 3 of full load When the weight displayed equal to the load weight p press to confirm The window will show done Remove the load from the weighing pan and the scale will restart and the calibration is done Linearity Calibration Procedure CAL 4 Note This section can only be operated by eng
3. GW Professional Weighing Scale User Manual SNOWREX INTERNATIONAL CO LTD SRGW 20100415 Table of Contents Taie or COM ENIS cicirenna EIER 1 SPENE ON ee E E E RR E E E E R 2 Basle SDECUEIC AH ON a Me acesas aes uaceaneece et casceeraacbasnnesoeotiacueusaie ee acsetecesdeanaatatctemeansdsoside 2 Series specification EC TYPE OIML APPROVED eeerer 2 series specification NON APPROV ED eese nnne 2 Display dnd Ke vDOuoeesaseiscosneeh ce ge wan abe AE AN E AA A E A 3 E DD DE erga 3 ICY LI EE PE EEE E TEE EE E E E E E E E A 4 Using the weiehint SCale sieioinico tae tinet bevd nina vedio i A n aA 6 Coun no TANC Oa O E E 6 PLC Cm Oe TUNC UO Mnman N 6 ODETA ONO M Faia ERU E NNS 6 ODEO OL NIR aia a T OA 6 A O ase E E E E A gene asin eee 7 Settings and Calbrablolt scrisori ta o E E A eats 8 General setmnes CAL I coser to st A A 8 Ponrsettie CAE cocansuucpiuium diesel E tee MR Rese Remo ar 9 Calibration Procedure CT o sso tdi eer vin cater io Ret isd ab e i meh edes 1 Linearity Calibration Procedure CAL 4 eeeeeeeeeeeeeeee 12 RS232C Connection DB 09 Male eie Hte eter EIU tS ees 13 Bi directional RS 232C Sell Mg oorieooeois oe teg rediens PO be toe po uiid e ES 13 Specifications Basic specification LCD height 17mm 6 6 Parameter WEIGHT 280 x 200 WxL Dimensions mm 280x300x110 WxLxH 0 Cto 40 C Re
4. become stable M press M to record another load weight After each recording if the load on the weighing pan is not cleared vressing ll will result in the beep and the scale won t be able to record the next weighing result e The stored memory can memorize up to 180 weighing results Operation of MR l In weighing mode press MR to display the accumulated weighing result The LCD display will show the total number of accumulation and the total weight alternatively For instance if you added two weighing results and the total weight add up to 4 0 kg The scale will show tot 002 and 4 000 kg M 2 Press to exit the MR mode without clearing the data in memory Alarm function ALARM t f 1 Press key to set the upper bound of the weight The Hi is showing in the left window 0 E 2 Setup the weight upper bound with the 1 amp keys Press D to confirm to save your Hi setting And then move to Lo setting 7 6 3 The Lo is showing in the left window Press the a amp keys to set the lower bound of the weight T 4 Press to confirm to save your Lo setting And then back to weighing mode Note e While the weight exceeds the upper bound of Weight Upper Bound or lower than the Weight Lower Bound or between the lower and upper bound and is not zero the scale may beep for warning You may change the beep settings in CAL I menu Settings and Calibration 1 Press and hold any key while turning the
5. ineers Please have the jumper JP3 switch OFF before you start the calibration process u C In Calibration menu press e to toggle among the menu options And press V to confirm 1 Zero Point Calibration Display D The AD Value i is then displayed in the right window AN T Make sure the weighing pan is empty Wait until the AD value becomes stable press to proceed 2 Calibration by 1 3 of the maximum capacity The AD Value of 1 3 of the full load is then displayed Put on poise of the 1 3 weight by the maximum capacity Wait until the AD value becomes stable Z T press to proceed 3 Calibration by 2 3 of the maximum capacity Description The AD Value of 2 3 of the full load 1s then displayed Put on poise of the 2 3 weight by the maximum capacity Wait until the AD value becomes stable Pih T press to proceed 4 Calibration by the maximum capacity Dipl u The AD Value of the full load is then displayed F dh ud gt Put on poise of full capacity of the scale Wait until the AD value becomes stable M The linearity calibration 1s complete RS232C Connection DB 09 Male Pin setup 2 TXD 3 RXD 5 GND others NC Bi directional RS232C Setting This section is applicable only for models with RS 232C module OUTPUT FORMAT STA U 55h indicates it s an unstable weight S 53h indicates it s a stable weight SIGN 2Dh means it s a negative weigh
6. lative Less than 85 DC9V 500mA AC adapter Built in 6V Rechargeable Battery nterface RS 232C optional Series specification EC TYPE OIML APPROVED Mot GW6D GWi5D GW 30D_ Max Max 3kg 6kg 6kg ibkg 5kg 30kg im Mim 20g 3kg 40g 6kg 100g 15kg g g 29 89 59 109 Series specification NON APPROVED dl GW 3H GW 6H GW 15H GW 30H i 1 30000 1 30000 1 30000 1 30000 Display and keypad LCD Display CHARGE bad Indicates the weight is stable Indicates the weight 1s at zero Indicates the total weights in memory Indicates the accumulation weights in memory M M W When V is shown above the G W indicator the Gross Weight 1s displayed E When V is shown above the NET indicator the Net Weight 1s displayed W G L E When the weight is over the weight upper bound P is flashing next to the Hi indicator lower bound is flashing next to the Go indicator When the weight is under the weight lower bound P is flashing next to the Lo indicator T When V is shown above the T W indicator the Tare Weight 1s displayed mM V is shown above the 5 when in counting mode 0 V is shown above the when in percentage mode kg amp Ib Indicate the unit of weight Keypad Zero key Press to absorb trivial weight on the pan and set the scale to zero 24 E3 Number setting Press 1 key to increase number and amp keys p
7. ress shift to shift the digit B Clear key Press to clear the input data M key Press to accumulate piece counting and weighing results MR key Press to recall total number of accumulation and total weighing Alarm key Press to set alarm for weight upper and lower bound m Backlight key Press to set backlight on or off Function key Press to toggle among weighing percentage and counting modes ao Sampling key Press to set up sample quantity of Percentage key Press to set up percentage of the given sample 4 g Press to switch between kg and lb Press to enter the ID mode Use the numeric keypad to enter the user s ID number key Weight and Tare Weight on the display Using the weighing scale Counting function 1 Put certain pieces of objects on to the scale pan 2 In weighing mode M and then use E keys to set the piece counts RI 3 Press to confirm 4 Now you are ready to perform parts counting for the specific samples Percentage function 1 Put certain pieces of objects on to the scale pan 4 Place objects of desired piece counts on the weighing pan The percentage of the objects will be calculated automatically Operation of M M 1 When there is a load on the weighing pan press after a beep sound the gt indicator let to M icon will light up on the LCD indicating a data has been recorded 2 Clear the load and put another load on the weighing pan When the scale
8. scale ON CAL 1 is shown on the LCD display 2 Press key to toggle among the CAL 1 CAL 2 CAL 3 and CAL 4 menus 3 Select CAL 1 press to enter General Settings menu 4 Select CAL 2 press to enter the Print Settings menu 6 Select CAL 3 press to enter Calibration procedure 7 Select CAL 4 press to enter Linearity Calibration procedure Note To perform CAL 3 and CAL 4 calibration you must remove the JP3 jumper from the PCB first Put the JP3 back after calibration is complete General Settings CAL 1 In the General Settings menu press c to toggle among the options and D to confirm 1 Aut oFF Auto Off Setting A oFF 0 Disable auto shutdown function A oFF 1 If there is no operation the scale will shut down in 5 minutes A oFF 2 If there is no operation the scale will shut down in 10 minutes A oFF 3 If there is no operation the scale will shut down in 20 minutes A oFF 4 If there is no operation the scale will shut down in 30 minutes 2 Pcnt dP Percentage decimal Setting Pcnt dP 0 0 100 0 95 Pcnt dP 0 00 100 00 3 bbH Hi Beep Setting Display Explanation bbH 0 Disable Hi alarm sound bbH 1 Set Hi alarm sound as continual short beeps bbH 2 Set Hi alarm sound as continual long beeps 4 bbS Go adt bbG _ 1 EXTA Hi alarm sound bbG 1 Set Hi alarm sound as continual short beeps bbG 2 Set Hi alarm sound as continual long beeps 5 bbL Lo Beep aem
9. t 20h space char indicates it s a positive or zero weight We Wo Weight data decimal point included SPACE 20h U1 Uo K 6Bh g 67h indicates that the unit is kilogram T 6CH b 62h indicates that the unit is Ib CR ODh LF OAh Command lt ENQ gt 05h the weight string not available when the print format is set to OFF or PRESS