Home

M-Series Remote Attendant Control, User Manual

image

Contents

1. Remote Attendant Control For Use WITH M SERIES ELECTRONICS 9 ATTENDANT CONTROL User Manual DEALER This manual contains important satety operational and set up instructions specitic to the Remote Attendant Control box Before using this product please read through the instructions carefully and save for future reference Concepts Motion TRDO323 REV B TABLE of CONTENTS 1 0 Remote Attendant Control Overview STANDARD MODE 2 0 Using the Remote as an Attendant Control 2 1 2 2 Attendant Control Operating Motor Functions Attendant Control Adjusting Motor Speed PROGRAM MODE 3 0 Programming Your Seating System via the Remote 3 1 3 2 3 3 3 4 3 5 3 6 Entering Program Mode Programming Options Configuring the Operator Attendant Switch Set Att Configuring the ASM for Joystick or Specialty Controls Set ASM Setting Limits and Lockout Angles Set Tipsy Setting Individual Actuator Motor Speeds Set Speed 4 0 Restricted Program Access for OEM use only 4 1 4 2 4 3 4 4 Setting Individual Actuator Functions On Off Set Actuator Miscellaneous On Off Feature Settings Set Config Setting Motor Type By Manufacturer Get Software Version Get Version 4x 1 0 REMOTE ATTENDANT CONTROL OVERVIEW LED Up Down Arrows o Standard Mode Operate Motor Function Indicator TOP Program Mode Alter Program Setting ATTENDANT CONTRO a Left Right Arr
2. the seating system is tilted reclined the back angle will be indicated in the upper right corner of the display screen for reference Tilt Recl Backward IMPORTANT Note Adjusting the Max_Angle on a Tilt Recline or Recline Only system The default Max Angle setting may vary from system to system and is pre set at the factory The Max Angl limit should only be adjusted it the maximum angle needs to be decreased trom the current factory set up Programming Instructions i To set the Max Recline angle the display angle indicator must be switched to Recline mode by pressing the left amp right arrows simultaneously A the display will change to show the recline angle range 90 1 689 ii Proceed to step 3 above 90 ooox 160 a 168 Max_Angl MES u EN Mor Press simultaneously to switch Back Angle Indicator Recline back to the Max Angl to Recline mode 90 168 in Recline Mode desired Max_ Angle 11 3 5 SETTING LIMITS AND LOCKOUT ANGLES Set Tipsy 4 Before saving verify that the angle amp tipsy position you wish to set are displayed on the screen e g DLO 25 then press the Select Save button 5 TWICE to save changes Each tipsy position must be saved individually following an adjustment Select Save Press TWICE to Save following each change 5 Repeat steps 2 4 as necessary to program remaining limits angles 6 To exit press the Exit Back button once
3. al Service Department to properly diagnose any potential issues it may be necessary to identify the software version of the remote attendant control Access to the Get Version display is available in the restricted program access section Note the current software version is also indicated briefly on the display screen when the remote attendant control is intially powered on 14 Concepts Motion USA 700 Ensminger Rd Suite 112 Tonawanda NY USA 14150 716 447 0050 888 433 6818 Canada 84 Citation Dr Units 1 7 Concord Ontario Canada L4K 1C9 905 695 0134 866 748 7943 www motionconcepts com
4. attendant switch Set ASM configuring joystick functions or specialty controls Set Tipsy set limits lockout angles Set Speed set individual actuator motor speeds Set Actuator On Off motor functions Set Config On Off settings for miscellaneous system features Set Motor Type set motor type by manufacturer Get Version indicates current software version Restricted Program Access Password Protected for OEM use only To Program the Operator Attendant Switch Box 1 In Program Mode scroll using Left Right arrows 1 until Set ATT SW is displayed on screen then press Select Save Button 2 2 Press any switch position 3 you wish to program on the operator switch box switch type may vary Note After pressing the switch screen display will indicate the assigned switch position i e SWI SW2 SW3 and the function currently assigned 3 3 CONFIGURING THE OPERATOR ATTENDANT SWITCH Set ATT SW 3 Use the Up Down arrows 4 to scroll through and select the motor function you wish to assign to the switch Images i iii illustrate the options available to assign the Tilt function to the SW1 switch position Switch Position Motor Function 4 Press the Select Save button 5 TWICE to save your changes Each change must be saved individually following adjustment 5 Repeat steps 2 4 as necessary to program remaining switch positions Select Save Press TWICE to Sa
5. both travel directions ALL SPD G 100 a 43 4 0 RESTRICTED PROGRAM ACCESS For OEM use ONLY WARNING Program modifications for the following sections Sections 4 1 4 4 are under Restricted Access for OEM use only To obtain access authorization for changes to these factory settings please contact Motion Concept s Technical Service Department Canada 800 680 4191 USA 888 433 6818 4 1 SETTING INDIVIDUAL ACTUATOR FUNCTIONS ON OFF Set Actuator Restricted Access Set Actuator functions are factory preset and Set C password protected Actuator functions may be individually Actuator gt programmed i e turned on and off Please contact our Technical Service Department if any changes to the existing set up are required 4 2 MISCELLANEOUS ON OFF FEATURE SETTINGS Set Config e Restricted Access The Configuration settings are factory preset and password protected Please contact our Technical Service Department if any changes to the existing set up are required Set 7 Config N 4 3 SETTING MOTOR TYPE BY MANUFACTURER Set Motor Type gt ra Restricted Access Motor Type settings are factory preset and Set a password protected If any changes are required please contact our Motor Type 2 e Technical Service Department for authorization to reconfigure the existing Motor Type settings 4 4 GET SOFTWARE VERSION Get Version Get Version IX In order for our Techinc
6. ft Puff A3 array control AI A2 are not Soft Si Zn typically recommended for of olip Al A2 power positioning applications 4 1 Ensure the function display is switched from Drive Mode into ASM mode 6 e g ASM1 ASM2 Note ASM1 and ASM2 are denoted by the letters A and B respectively during programming i e ASM1 Al A2 A3 A4 and ASM2 B1 B2 B3 B4 4 2 Activate the specialty control that you wish to program see example 7a The remote display will automatically indicate the assigned control i e A1 A2 A3 A4 and display the motor function that is currently assigned to it see example 7b example Function Head Display Array Assigned Control Motor Function programmable 4 3 Use the Up Down arrows 8 to scroll through and select the motor function you wish to assign to the specialty control see images i iii i y Specialty Control Motor Function Images i iii illustrate the program options available to assign the Tilt function to the A3 control position NOTE To turn off a specialty control switch i e A1 A2 scroll through the Motor Function options until the OFF command is displayed on the screen This will prevent the switch from activating 5 To save changes press the Select Save button 9 TWICE Each change must be saved individually following adjustment 6 Repeat steps 2 5 as necessary to program remaining controls 7 Press the Exit Back button o
7. ing systems using a Joystick Control proceed to Step 3 below For systems equipped with Specialty Controls e g Sip N Puff Head Array etc proceed to Step 4 p 9 3 Programming for Thru Joystick Controls 3 1 Ensure the joystick display is switched from Drive Mode into ASM mode 3 e g ASM1 ASM2 Note ASM1 and ASM2 are denoted by the letters A and B respectively during programming i e ASM1 Al A2 A3 A4 and ASM2 Bl B2 B3 B4 3 2 Press the joystick control in the direction that you wish to program see example 4a The remote display will automatically indicate the assigned joystick position i e Al A2 A3 A4 and display the motor function that is currently assigned to it see example 4b Joystick Control Joystick Display Joystick l Control Joystick Control Motor Function programmable Remote Display e g Joystick 3 3 Use the Up Down arrows 5 to scroll through and select the motor function you wish to assign to the joystick control position see images i iii Joystick Position A1 i 7 A1 A1 4 Motor Function x z 9 Images i iii illustrate the program options available to assign the Recline function to the Al joystick position 3 4 To save your changes proceed to Step 5 4 Programming for Specialty Controls if applicable Head Array Y Sip N Puff Control Control A4 Hard Puff Al Hard Sip A2 Please Note On a head So
8. n not in use the screen display is designed to enter into sleep mode after 10 sec in Standard mode and after 120 sec in Program mode Pressing any button on the remote will re awaken the display LED INDICATOR The LED light is a visual signal as to the position status of the power positioning system The LED light on remote box is designed to mirror the indicator lights on the 4 way and 8 way switch boxes Green Light indicates that seating system is in the Home position Flashing Green indicates that seating system is Out of Home Flashing Red indicates that a Tllt Recline and or Elevating system is in Reduced Speed Drive Red Light indicates the seating system is in Drive Lockout DLO STANDARD MODE 2 0 USING THE REMOTE AS AN ATTENDANT CONTROL In Standard Mode the remote operates as an attendant control box using the Left Right arrows to cycle through the available motor functions on the power positioning system PPS and the Up Down arrows to operate the selected motor function 2 1 ATTENDANT CONTROL OPERATING MOTOR FUNCTIONS 1 Use Left Right arrows 1 to scroll through the available power positioning motor functions i e Tilt Recline Elevate etc Note the remote will only display the power positioning functions that are available 2 Select the desired motor function in the screen display then press and hold the Up Down arrows 2 and 3 to operate the actuator The power positioning f
9. nce to return to the Program Options Exit 7 Select Save screen Press twice to fully Exit program mode Back Press TWICE to Save following each change 10 3 5 SETTING LIMITS AND LOCKOUT ANGLES Set Tipsy Important When adjusting programming the Tipsy Sensor please note that the Home Reduce DLO and Max Angle limits are contiguous Each limit angle must be set to a greater or equal angle than the previous To Program the Limits and Lockout Angles Ensure seating system is on a level surface in the full upright position prior to programming the tipsy 1 In Program Mode scroll using Left Right arrows 1 until Set Tipsy is displayed on screen then press the Select Save button 2 2 Use the Left Right arrows 3 to scroll through and select the tipsy position you wish to adjust Home sets home position angle Reduce sets reduced speed drive angle DLO sets drive lockout angle Max_Angl sets the maximum Tilt or Recline or Tilt Recline angle see Important note below Reset resets existing limits to reset press Select Save TWICE Note Resetting the Tipsy requires the Home Reduce and DLO limits to be re programmed Following a reset the Max_Ang limit will be automatically defaulted Back Angle to the maximum allowable angle Tilt Recl Forward Indicator 3 Press the Up Down arrows 4 to adjust the seating system to the desired angle See Recommended Tipsy Angles p 11 Note as
10. or Motor Speeds 1 In Program Mode scroll using Left Right arrows 1 until Set Speed NE y is displayed on screen then press the Select Save Button 2 Speed 2 Use the Left Right arrows 3 to scroll through and select the actuator function for which you would like to adjust the motor speed TILTFWD 2 Tilt Fwd Tilt Bwd See Optional ALL SPEED Adjustment below mon 3 Use the Up Down arrows to adjust the motor speed for the selected motor function Press adjustment arrow 4 to decrease or 5 to increase the motor speed in 1 increments Hold down adjustment arrow 4 to decrease or 5 to increase the motor speed in 5 increments Hold down both adjustment buttons simultaneously 6 to RESET the selected actuator speed back to 100 Images i iii illustrate motor speed adjustments made to the Tilt Fwd actuator function 4 To save changes press the Select Save button 7 TWICE Each speed adjustment must be saved individually following modification 5 Repeat steps 2 4 as necessary to program remaining limits Select Save Press TWICE to Save following each change Exit Back 6 Press the Exit Back button once to return to the Program Options screen Press twice to exit program mode OPTIONAL ALL SPEED Adjustment The motor speed for all actuator functions can be programmed simultaneously via the ALL SPD function The ALL SPD setting configures all actuators to the identical speed in
11. ows Standard Mode SelectMotor Function Program Mode Scroll Program Options Exit Back Select Save Button Button STANDARD MODE In Standard Mode the remote operates as an attendant control box using the Left Right arrows to cycle through the available motor functions on the power positioning system PPS and the Up Down arrows to operate the selected motor function PROGRAM MODE In Program Mode the remote functions as a hand held programmer to allow qualified technicians the flexibility to reconfigure the PPS to better meet the specific needs of the end user when necessary Program options include reconfiguring operator switch and joystick assignments setting of limits amp lock out angles setting individual motor speeds etc IMPORTANT Program Mode on the remote is password protected To enter into Program Mode press the Select Save and Exit Back buttons simultaneously When the Enter Password prompt appears in the screen display press the directional arrows in the following sequence up up down down SELECT SAVE BUTTON The select save button is used in Program Mode to select enter the specific option function you wish to re program and is utilized to save your changes once programming is completed EXIT BACK BUTTON The exit back button is utilized during Program Mode to return to the previous screen display or to exit at any stage during programming without saving your changes SCREEN DISPLAY Whe
12. to return to the Program Exit Back Options screen Press twice to exit program mode Recommended Tipsy Angles The tipsy angle sensors allows for the individual programming of up to 4 limits Home Anti Tip Limit Reduced Speed Drive DLO Limit and the Max Tilt Tilt Recline Limit Refer to the following factory recommended limit lockout angles when programming the Tipsy Sensor Home Position 0 to 20 Reduced Speed Drive Limit Max Limit 20 Drive Lockout DLO Limit Max DLO 30 Max DLO 25 if Reduced Drive is not programmed Maximum Back Angle Max Tilt Limit 55 Tilt only 50 Tilt Only Module or 45 Scissor Lift Tilt module Max Tilt Recline Limit 168 Tilt Recl Recl only Note Do Not exceed the max recommended DLO 2Note for bariatric systems the Max Back Angle may be limited to 30 or 45 based on client weight WARNING Risk of severe injury or death The angle at which limits are set is critical to the sate operation of the power positioning system Motion Concepts will not be liable for any injuries or damage sustained when adjustments are made beyond the factory recommended settings 12 3 6 SETTING INDIVIDUAL ACTUATOR MOTOR SPEEDS Set Speed Motor speeds are shown as a percentage value and may be set independently for each direction of travel i e Tilt Fwd Tilt Bwd Recl Fwd etc Default Setting 100 Full Speed See also Section 2 2 p 5 To Program the Actuat
13. unction and direction of travel will be indicated on the display screen See example below showing Tilt function 2 2 ATTENDANT CONTROL ADJUSTING MOTOR SPEED Motor speeds may be adjusted independently while in attendant control standard mode In standard mode the Exit Back and Select Save buttons function as Speed Down and Speed Up while operating a motor function 1 Select the motor function and direction you wish to adjust gt JANT cc e 2 To decrease the motor speed press the Speed Down button left while Motor E gt Direction u simultaneously pressing the motor function direction button 1 X 3 To increase the motor speed press the Speed Up button right while simultaneously pressing the motor function direction button 2 Speed Speed Down Up e g Adjusting Tilt Backward speed Decrease Motor Speed Increase Motor Speed ET A BACKWARD A PROGRAM MODE 3 0 PROGRAMMING YOUR SEATING SYSTEM VIA THE REMOTE 3 1 ENTERING PROGRAM MODE To Enter Program Mode 1 Press both lower buttons simultaneously 1 to access passwo rd screen 2 Enter Password using key pad 2 Press the up arrow twice followed by the down arrow twice Password Sequence UP UP DOWN DOWN 3 2 PROGRAMMING OPTIONS Select Program Option 1 Use Left and Right arrows 1 to scroll through available Program Options Set ATT SW configuring operator
14. ve following 6 To exit press the Exit Back button once to return to the Program each change Options screen Press twice to fully Exit program mode Exit Back TOP Default Switch Number Assignments TOP for reference during programming LED LED TOP 8 Way Switch Quad Push Dual Push AWe I Bual Tegel Way ogg e id de Button Button Optional Splitter Cables Additional Switches may be added by connecting a splitter cable into the switch port on the M Series Seat Controller Their are two models of Splitter cables available C648 2 way Splitter C654 3 way Splitter Both splitters are configurable up to a maximum of 12 programmable switches A Vu The Remote will automatically recognize and number the additional Or ra N switch ports to seat controller switches for programming i e SW1 SW2 SW11 SW12 10 pin micro molex switch input The C648 splitter must be configured using one 8 Way Switch in one port combined with any other switch in the remaining port up to 4 functions C648 2 way splitter The C654 splitter may be configured for use with up to three 4 Way Switches one in each port or it may be configured to utilize any switch combinations up to the maximum 12 switches C654 3 way splitter Configuring the ASM 1 In Program Mode scroll using Left Right arrows 1 until Set ASM is displayed on screen then press the Select Save Button 2 2 For programming instructions on seat