Home
LAGAN HGA4K Gas hob
Contents
1. HGA4K IT Design and Quality IKEA of Sweden GB ENGLISH m Language Country ENGLISH Contents Safety information Product description Daily use Helpful hints and tips Care and cleaning N 001014 Subject to change without notice A Safety information For your safety and correct operation of the appliance read this manual carefully before installation and use Always keep these instructions with the appliance even if you move or sell it Users must fully know the oper ation and safety features of the appliance Correct use e Do not leave the appliance unattended dur ing operation e The appliance is designed exclusively for domestic use e The appliance must not be used as a work surface or as a storage surface e Do not place or store flammable liquids highly inflammable materials or fusible ob jects e g plastic film plastic aluminium in or near the appliance e Watch out when connecting electric appli ances to sockets nearby Do not allow con necting leads to come into contact with or to catch underneath the appliance or hot cook ware Do not do repairs yourself to prevent injury and damage to the appliance Always con tact your local After Sales Service refer to the Service chapter Child safety e Only adults can use this appliance Children must get supervision to make sure that they do not play with the appliance e Keep all packaging away from c
2. SE 34381 Almhult should be taken to the appropriate collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent ENGLISH potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact your local council your household waste disposal service or the shop where you purchased the product Packaging materials The materials with the symbol are recycla ble Dispose the packaging in a suitable col lection containers to recycle it IKEA GUARANTEE How long is the IKEA guarantee valid This guarantee is valid for five 5 years from the original date of purchase of Your appli ance at IKEA unless the appliance is named LAGAN in which case two 2 years of guar antee apply The original sales receipt is re quired as proof of purchase If service work is carried out under guarantee this will not ex tend the guarantee period for the appliance Which appliances are not covered by the IKEA five 5 years guarantee The range of appliances named LAGAN and all appliances purchased in IKEA before 1st of August 2007 Who will execute the service IKEA service provider will provide the service through its own service operations or author ized service partner network What does t
3. a di viding panel at a minimum distance of 20 mm from the bottom of the hob Protect the cut surfaces of the worktop against moisture using a suitable sealant included in the product in fitting bag The sealant seals the appliance to the work top with no gap Do not use silicon sealant between the appliance and the worktop Avoid installing the appliance next to doors and under windows as hot cook ware may be knocked off the pan support when doors and windows are opened Only an authorized service engineer can in stall connect or repair this appliance Any gas installation must be carried out by a GAS SAFE REGISTER installer Use only original spare parts Gas Connection A Warning This appliance is not connected to a combustion products evacuation device Installation must comply with current local reg ulation ENGLISH The connection of the cooktop to the gas pipe network or gas cylinder must be made by means of a rigid copper or steel pipe with fit tings complying with local regulations or by means of a continuous surface stainless steel hose complying with local regulations If you see any abnormalities do not repair the pipe contact local After Sales Service refer to the Service chapter The connection must be installed correctly fixed into hob connection pipe Otherwise it will cause leakage of gas A Warning Once the installation is complete check the perfect seal of every pipe fixing Use soapy wate
4. well clean to avoid difficult light ning O Periodically ask your local Service Centre to check the conditions of the gas supply pipe and the pressure adjuster if it is fitted this service is not free of charge After cleaning be sure to wipe dry with a soft cloth Problem Possible cause Remedy There is no spark when light ing the gas There is no electrical supply Check that the unit is plugged in and the electrical supply is switched on Check the house electric in stallation fuse Burner cap and Crown are placed uneven Check the burner cap and crown have been replaced correctly e g after cleaning The flame is blowing out im mediately after lightning enough Thermocouple is not heated After lightning the flame keep the knob pushed for about 5 sec The gas ring burns unevenly food residues Burner crown is blocked with Check the main injector is not blocked and the burner crown is clear of food particles If there is a fault first try to find a solution to the problem yourself If you cannot find a sol ution to the problem yourself contact your dealer or the After Sales Service If you operated the appliance wrongly or the installation was not carried out by a registered engineer the visit from the customer service technician or dealer may not take place free of charge even during the warranty period ENGLISH Technical data Hob dime
5. antee to apply Note that the receipt reports also the IKEA article name and number 8 digit code for each of the appliances you have purchased Do You need extra help For any additional questions not related to Af ter Sales of your appliances please contact our nearest IKEA store call centre We recom mend you read the appliance documentation carefully before contacting us Belgi Binnenlandse gesprekskosten 8 tot 20 Weekdagen 070 246016 Belgique Tarif des appels nationaux 8 20 En semaine Benrapua 0700 10 218 Takca 30 noBukBaHe OT CTpaHaTa Or 9 no 18 u B pabotHu ann esk republika 246 019721 Cena za mistni hovor 8 az 20 v pracovnich dnech man fre 09 00 20 00 Danmark 70 15 09 09 Landstakst l r 0 00 16 00 1 s ndag pr m ned normalt f rste s ndag i m neden Deutschland 01803 334532 0 09 Min aus dem Festnetz der DTAG Mobilfunkpreise abweichend 8 bis 20 Werktage EM G6a 211 176 8276 Yrrepaot kr kA on 8 Ewg 20 kat tic EPY OULEG NU PEG Espa a 91 1875537 Tarifa de llamadas nacionales De 8 a 20 en dias laborables France 0170 36 02 05 Tarif des appels nationaux 9 21 En semaine Ireland 0 14845915 National call rate 8 till 20 Weekdays island 5880503 Innanlandsgjald fyrir sima 9 til 18 Virka daga Italia 0200620818 Tarife applicata alle chiamate dalle 8 alle 20 nei giorni feriali na
6. ection to the wrong voltage damage caused by chemical or electro chemical re action rust corrosion or water damage in cluding but not limited to damage caused by excessive lime in the water supply damage caused by abnormal environmental condi tions e Consumable parts including batteries and lamps e Non functional and decorative parts which do not affect normal use of the appliance including any scratches and possible color differences e Accidental damage caused by foreign ob jects or substances and cleaning or unblock ing of filters drainage systems or soap drawers ENGLISH Damage to the following parts ceramic glass accessories crockery and cutlery bas kets feed and drainage pipes seals lamps and lamp covers screens knobs casings and parts of casings Unless such damages can be proved to have been caused by pro duction faults Cases where no fault could be found during a technician s visit e Repairs not carried out by our appointed service providers and or an authorized service contractual partner or where non original parts have been used e Repairs caused by installation which is faulty or not according to specification e The use of the appliance in a non domestic environment i e professional use e Transportation damages If a customer transports the product to their home or other address IKEA is not liable for any damage that may occur during transport However if IKEA delivers the p
7. fire in kitchen environment Manufacturer decline any responsibility in case misuse of the flame If the burner accidentally goes out turn the control knob to the off position and wait for at least 1 minute before trying to light it again When switching on the mains after in stallation or a power cut it is quite normal for the spark generator to be activated auto matically Turning the burner off To put the flame out turn the knob to the sym bole A Warning Always turn the flame down or switch it off before removing the pans of the burner Burner minimum diam maximum di eter of pots and ameter pots pans and pans Rapid 180 mm 260 mm Semi 120 mm 220 mm rapid Auxili 80 mm 160 mm ary ENGLISH The bottom of the cookware should be as thick and flat as possible Care and cleaning A Warning Switch the appliance off and let it cool down before you clean it A Warning For safety reasons do not clean the appliance with steam blasters or high pressure cleaners A Warning Do not use abrasive cleaners steel wool pads or acids they will damage the appliance To remove any food remains wash the enam elled elements caps and crowns with warm soapy water Stainless steel elements wash with water and then dry with a soft cloth What to do if This model is equipped with electrical ignition it is obtained through ceramic candle and electrode Keep them
8. hildren There is a risk of suffocation e Keep children away from the appliance when it is on 4 What to do if 7 Technical data 8 Installation 9 Environment concerns 11 IKEA GUARANTEE 12 General safety e This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruc tion concerning use of the appliance by a person responsible for their safety Ensure there is a continuous air supply while using the hob keep air vents in good con dition or install a cooker hood with a venting hose Improve ventilation by opening a win dow or increasing the extractor speed e This appliance is supplied with safety device in form of the thermocouple If after ignition of the burner or during use flame will go out and the thermocouple will not be heat up enough gas supply will be interrupted Installation e Make sure that the appliance is not dam aged because of transport Do not connect a damaged appliance If necessary contact the After Sales Service refer to the Service chapter e Only an authorized service engineer can in stall connect or repair this appliance Use only original spare parts e Built in appliances can only be used after they are built into suitable built in units and work surfaces that meet standards Do not change the specifications or modify this produc
9. his guarantee cover The guarantee covers faults of the appliance which have been caused by faulty construction or material faults from the date of purchase from IKEA This guarantee applies to domestic use only The exceptions are specified under the headline What is not covered under this guarantee Within the guarantee period the costs to remedy the fault e g repairs parts la bour and travel will be covered provided that the appliance is accessible for repair without special expenditure On these conditions the EU guidelines Nr 99 44 EG and the respec tive local regulations are applicable Replaced parts become the property of IKEA 12 Before disposal of appliance A Warning Do these steps to dispose the appliance e Pull the mains plug out of the mains socket Cut off the mains cable and discard it What will IKEA do to correct the problem IKEA appointed service provider will examine the product and decide at its sole discretion if it is covered under this guarantee If consid ered covered IKEA service provider or its au thorized service partner through its own serv ice operations will then at its sole discretion either repair the defective product or replace it with the same or a comparable product What is not covered under this guarantee e Normal wear and tear e Deliberate or negligent damage damage caused by failure to observe operating in structions incorrect installation or by con n
10. nsions width 580 mm depth 500 mm built in height 12mm Class Appliance 3 Appliance Category II2H3 Appliance gas supply Natural gas G20 2H 20 mbar This appliance is designed for use with natural gas but can be converted for use with other gas type according to table below Nominal Flow g h Burner Injectors Nominal Reduced by pass Type of Gas ne 1 100 Power G30 G3137 Power 1 100 Me mm kW 28 30 mbar kW mm mbar G2020 Rapid 119 3 0 0 75 42 mbar large i j Semi rapid 96 2 0 e 0 45 32 medi um Auxili ary 70 1 0 0 33 28 small G30 G31 Rapid 28 30 37 p 86 2 8 204 200 0 75 42 large mbar Semi rapid 71 2 0 145 143 0 45 32 medi um Auxili ary 50 1 0 73 71 0 33 28 small Rating Plate Made In Italy Inter IKEA Systems B V 1999 301 560 09 y Pam 21552 D C x PNC 949620663 TYPE H6ML40 4 VA 060ce ZO 0051 wm G20 20 mbar 8 kW 112H6 GB G31 37mbar 557 g h G30 28 30 mbar 567 g h 230 V 50 Hz ENGLISH The graphic above represents rating plate of the appliance without serial number which is generated dynamically during the production process which is located at its underneath surface of the casing Installation Manufacturer is not responsible for any injury to persons and pets or damage to property caused by failure to comply following require ments A Cauti
11. on To proceed with the installation refer to the assembly instructions A Warning Installation process must follow the laws ordinances directives and standards electrical safety rules and regulations proper recycling in accordance with the regulations etc in force in the country of use Ensure that the local distribution condi tions nature of the gas and gas pressure and the adjustment of the appliance are com patible before proceeding with the installa tion The parameters of adjustment setting for this appliance are stated on the rating plate refer to the Technical data chapter A Warning The appliance must be earthed A Warning Risk of injury from electrical current e The electrical mains terminal is live e Make electrical mains terminal free of volt age e Loose and inappropriate plug and socket connections can make the terminal over heat Dear Customer please apply here aside the sticker you can find in the dedicate plastic bag inserted inside the hob packaging This will al low us to assist you better by identifying pre cisely your hob in case you will need in future our assistance Thank you for your help e Have the clamping connections correctly in stalled e Use strain relief clamp on cable Important You must observe the minimum distances to other appliances and furniture cabinets or other units according to Assembly Instruction If there is no oven beneath the hob insert
12. placed in order that in each part it cannot reach a 90 C tem perature The blue neutral cable must be con nected to the terminal block marked with N The brown or black phase cable fitted in the terminal block contact marked with L must always be connected to the live phase ENGLISH Gas setting conversion O This model is designed for use with natu ral gas but can be converted for use with butane or propane gas providing the correct injectors The injectors not supplied with the appliance have to be ordered from After Sales Service refer to the Service chapter For data concerning injector replacement see chapter Technical data A Warning Conversion or replacement can only be performed by a registered installer To replace injectors 1 Remove pan support 2 Remove burner cap and crown 3 With a socket spanner 7 unscrew and re move the injectors replace them with the ones required for the type of gas in use 4 Reassemble the parts following the same procedure backwards Important Replace the rating label placed near gas supply pipe with relevant one for the new type of gas supply before sealing the appliance If the appliance is already sealed please stick it directly on the user manual booklet after Technical data chapter close to the rating plate drawing O You can find this label in package sup plied with appliance O If the feeding gas pressure will be differ ent or variable compa
13. r never flame Electrical connection Before connecting check that the nominal volt age of the appliance stated on the rating plate corresponds to the available supply voltage Also check the power rating of the appliance and ensure that the wire is suitably sized to suit the appliance power rating refer to the Technical data chapter The rating plate is located on the lower casing of the hob The appliance is supplied with a connection cable This has to be provided with a proper plug able to support the load marked on the identification plate To connect the plug to the cable follow the recommendation given in fol lowing figure 10 Replacement of the connection cable The replacement of the connection cable re quires the specific equipment of a technician In this case only cable type HO5V2V2 F T90 must be used The cable section must be suit able to the voltage and the working temper ature The yellow green earth wire RA must be approximately 2 cm longer than the brown or black phase wire EE previous figure The plug has to be fitted in a proper socket If connecting the appliance directly to the elec tric system it is necessary that you install a double pole switch between the appliance and the electricity supply with a minimum gap of 3 mm between the switch contacts The dou ble pole has to be of a type suitable for the required load in compliance with the current rules The connection cable has to be
14. ring with the re quired you must install an appropriate pres sure adjuster which is not supplied with the product and if needed must be ordered sep arately from the local After Sales Service refer to the Service chapter The pressure adjuster must be fitted on gas supply pipe in compli ance with the rules of the force Environment concerns The symbol X on the product or on its packaging indicates that this product may not be treated as household waste Instead it 11 The rating plate is located on the lower casing of the hob Adjusting flame level When hob has been fully installed it is neces sary to check the minimum flame setting 1 Turn the gas tap to the maximum position and ignite 2 Set the gas tap to the minimum flame po sition then turn the control knob from mini mum to maximum several times If the flame is unstable or extinguished follow the pro cedure further Re ignite the burner and set to minimum Remove the control knob To adjust use a thin bladed screwdriver and turn the adjustment screw until the flame is steady and does not extinguish when the knob is turned from minimum to maximum and vice versa see following picture Era 6 Repeat this procedure for all burners 7 Reassemble the knobs Warning If the appliance is connected to liquid gas G31 propane or G30 butane the regulation screw must be fastened as tightly as possible d IKEA of Sweden AB
15. roduct to the customer s delivery address then damage to the prod uct that occurs during this delivery will be covered by this guarantee e Cost for carrying out the initial installation of the IKEA appliance However if an IKEA service provider or its authorized service partner repairs or replaces the appliance under the terms of this guarantee the serv ice provider or its authorized service partner will re install the repaired appliance or in stall the replacement if necessary This restriction do not apply to fault free work carried out by a qualified specialist using our original parts in order to adapt the appliance to the technical safety specifications of another EU country How country law applies The IKEA guarantee gives You specific legal rights which covers or exceed local demands However these conditions do not limit in any way consumer rights described in the local legislation 13 Area of validity For appliances which are purchased in one EU country and taken to another EU country the services will be provided in the framework of the guarantee conditions normal in the new country An obligation to carry out services in the framework of the guarantee exists only if the appliance complies and is installed in ac cordance with e the technical specifications of the country in which the guarantee claim is made the Assembly Instructions and User Manual Safety Information The dedicated After Sale
16. s Service for IKEA appliances Please do not hesitate to contact IKEA After Sales Service to 1 make a service request under this guaran tee 2 ask for clarification on installation of the IKEA appliance in the dedicated IKEA kitchen furniture The service won t provide clarifications related to the overall IKEA kitchen installation connections to electricity if machine comes without plug and cable to water and to gas since they have to be execu ted by an authorized service engineer 3 ask for clarification on user manual con tents and specifications of the IKEA appli ance To ensure that we provide you with the best assistance please read carefully the Assembly Instructions and or the User Manual section of this booklet before contacting us How to reach us if You need our service Please refer to the last page of this manual for the full list of IKEA appointed contacts and rel ative national phone numbers ENGLISH Important In order to provide You with a quicker service we recommend that You use the specific phone numbers listed at the end of this manual Always refer to the numbers listed in the booklet of the specific appliance You need an assistance for Before calling us assure that You have to hand the IKEA article number 8 digit code for the appliance of which you need our assistance Important SAVE THE SALES RECEIPT It is Your proof of purchase and required for the 14 guar
17. sition there is maximum gas supply there is minimum gas supply 1 Push the electric ignition button witch is marked by a little spark X at the same time turn the relevant control knob anti clockwise to maximum position AN ENGLISH 2 Keep the knob pushed for about 5 sec this will allow thermocouple to heat up and the safety device to switch off otherwise the gas supply would be interrupted 3 After the flame is regular adjust it as pre ferred If after a few attempts the burner does not ignite check that the crown and its cap are in correct positions Burner cap Burner crown Ignition candle El Injector Thermocouple A Warning Do not keep control knob pressed for more than 15 seconds If the burner does not light after 15 seconds release the control knob turn it into off position and wait for at least 1 minute before trying to light the burner again Helpful hints and tips Energy savings If possible always place lids on the pans e As soon as liquid starts boiling turn down the flame to barley keep the liquid simmer ing Use pots and pans with bottom fitting the size of burner used Important In the absence of electricity You can ignite the burner without electrical device in this case approach the burner with a flame push the relevant knob down and turn it counter clockwise to maximum gas release position A Warning Maintain extreme caution when using open
18. t Risk of injury and damage to the appliance A Warning Carefully obey the instructions for electrical and gas connections ENGLISH e Do not install the appliance if it is damaged during the transportation Safety during use e Remove all packaging stickers and film from the appliance before the first use A Warning Fire hazard Overheated fats and oils can ignite very quickly e Switch the burners off after each use e Risk of burns Burners and accessible parts become hot during use Make sure pots do not protrude over the edges of the cooktop Product description Auxiliary burner Rapid burner Semi Rapid burner EX Semi Rapid burner Semi Rapid burner control knob D Semi Rapid burner control knob Rapid burner control knob EJ Auxiliary burner control knob Daily use Ignition of the burner Always ignite the burner before position ing pots or pans To ignite the burner How to avoid damage to the appliance To avoid damaging the hob do not allow saucepans or frying pans to boil dry Donotuse the burners with empty cookware or without cookware e Never line any part of the appliance with aluminium foil Never place plastic or any other material which may melt on the appli ance EN Ignition button Removable pan supports Burner control knob The burner control knobs are situated on the right side of the hob o Symbol Description o there is no gas sup ply off po
19. zionali Kurrpog 22 030 529 Yrrepaot kr kA on 8 Ewg 20 kat TIG EPY OUEG NU PEG Magyarorsz g 061 998 0549 Belf ldi d jszab s H tk znap 8 s 10 ra k z tt 0900 235 45 32 i PER ma vr 9 00 21 00 Nederland and or ee zat 9 00 20 00 0900 BEL IKEA zon 9 00 18 00 Norge 815 22052 Takst innland 8 til 20 ukedager sterreich 0810 300486 zum Ortstarif 8 bis 20 Werktage Polska 012 297 8787 Stawka wg taryfy krajowej Od 8 do 20 w dni robocze Portugal 211557985 Chamada Nacional S as a da semang excepto feriados Rom nia 0212121224 Tarif apel na ional 8 20 n zilele lucr toare Pocus 8 495 6662929 He creytoune renedonHbie c 8 no 20 no pa6ouum AHaM Tapucbbl Bpema mockoBckoe Schweiz Tarif f r Anrufe im Bundesgebiet 8 bis 20 Werktage Suisse 031 5500 324 Tarif des appels nationaux 8 20 En semaine Svizzera Tanta applicata Gk chiamai dalle 8 alle 20 nei giorni feriali nazionali Slovensko 02 3300 2554 Cena vn tro t tneho hovoru 8 a 20 v pracovn ch d och Suomi 0207 85 1000 Kotimaan puhelun hinta arkip ivisin 8 00 20 00 A m n fre 8 30 20 00 Sverige 0775 700 500 lokalsamtal lokal taxa l r s n 9 30 18 00 T rkiye 212 244 0769 Ulusal arama creti Hafta i i saat 09 00 dan 18 00 a kadar Ykpa Ha 044 586 2078 MixKMICbKN A3BIHKN NATH 9 21 B po6oui ani United Kingdom 020 3347 0044 National call rate 9 till 21 Weekdays Inter IKEA Systems B V 2008 AA 401627 1 397109501 B 092009
Download Pdf Manuals
Related Search
Related Contents
SCADASense 4203 DR - Control Microsystems 399 - sr 927 w funzioni regata con allarme e data yatching Italy www.diasorin.com LIAISON® Direct Renin Dureté & résistance à la rayure Samsung PN50B540S3F Manuel de l'utilisateur select - Amprobe グラム陰性菌同定用 - 日本ベクトン・ディッキンソン Copyright © All rights reserved.
Failed to retrieve file