Home

File

image

Contents

1. 8 RSAS3300A Series www tektronix com rsa Displayed Average Noise Level Typical dBm Hz Frequency Typical 1 kHz to 10 kHz 144 10 kHz to 10 MHz 151 10 MHz to 100 MHz 151 100 MHz to 1 GHz 150 1 GHz to 2 GHz 150 2 GHz to 3 GHz 150 3 GHz to 5 GHz 5 142 5 GHz to 8 GHz 142 5 Frequency gt 3 MHz available on RSA3308A WCA280A only Real Time Spectrum Analyzers RSA3303A e RSA3308 e WCA230A e WCA280A Frequency Response 20 C to 30 C RF ATT 210 dB E Frequency Spec Typical 100 kHz to 40 MHz 0 5 dB x 0 3 dB 40 MHz to 3 0 GHz 1 2 dB x 0 5 dB 3 0 GHz to 6 5 GHz 1 7 dB 1 0 dB 5 GHz to 8 GHz 1 7 dB 1 0 dB 5 Frequency gt 3 MHz available on RSA3308A WCA280A only Inputs and Outputs Front Panel Input Connectors N type RF Baseband BNC type IQ Opt 03 Input Impedance 50 Q Preamp Power Connector LEMO 6 pin connector Pin 1 NC Pin 2 ID1 Pin 3 ID2 Pin 4 12 V Pin 5 GND Pin 6 12 V External Preamp Opt 1A 100MHz to 3GHz 20 dB gain 6 5 dB Noise Figure at 2 GHz typical Rear Panel 10 MHz REF OUT 50 Q BNC gt 3 dBm 10 MHz REF IN 50 Q BNC 10 dBm to 6 dBm Ext Trig In Ext Trig BNC High 1 6 V to 5 0 V Low 0 V to 0 5 V GPIB Interface IEEE 488 2 Trigger Out 50 Q BNC High gt 2 0 V Low 0 4 V output current 1 mA RSAS3300A Series www tektronix com rsa Side
2. Product Options e Opt 02 65 5 MSample Deep Memory Frequency Mask Trigger Opt 03 IQ Differential IQ Inputs Opt 23 W CDMA Uplink Analysis Opt 24 GSM EDGE Analysis Opt 25 CDMA 1X Forward Reverse Link Analysis Opt 26 1X EVDO Forward Reverse Link Analysis Opt 27 3GPP Release 5 Downlink HSDPA Analysis Opt 28 TD SCDMA Analysis Opt 40 GPP Release 6 HSUPA Analysis Opt 1A External Preamp 100 MHz to 3 GHz 20 dB gain 6 5 dB Noise Figure at 2 GHz typical Opt 1R Rackmount kit Opt SASW USB Stand alone Software Key 6 Specifications for Options 21 through 40 can be found in the Real Time Spectrum Analyzer Software Options datasheet on www tektronix com rsa 7 Option 23 and Option 27 are required for 3GPP Release 6 HSUPA Analysis in addition to Option 40 Upgrades WCA2UP 02 65 5 MSample Deep Memory Frequency Mask Trigger WCA2UP 03 IG Differential IQ Inputs WCA2UP 23 W CDMA Uplink Analysis customer installable WCA2UP 24 GSM EDGE Analysis customer installable WCA2UP 25 cdma2000 1x Analysis customer installable WCA2UP 26 1x EV DO Analysis customer installable WCA2UP 27 3GPP Release 5 Downlink HSDPA Analysis customer installable WCA2UP 28 TD SCDMA Analysis Software customer installable RSA34UP40 3GPP Release 6 HSUPA Analysis Software Upgrade customer installable WCA2UP 1A External P
3. 1 800 661 5625 Central East Europe Ukraine and the Baltics 41 52 675 3777 Central Europe amp Greece 41 52 675 3777 Denmark 45 80 88 1401 Finland 41 52 675 3777 France 33 0 1 69 86 81 81 Germany 49 221 94 77 400 Hong Kong 852 2585 6688 India 91 80 22275577 Italy 39 02 25086 1 Japan 81 3 6714 3010 Luxembourg 44 0 1344 392400 Mexico Central America amp Caribbean 52 65 5424700 Middle East Asia and North Africa 41 52 675 3777 The Netherlands 090 02 021797 Norway 800 16098 People s Republic of China 86 10 6235 1230 Poland 41 52 675 3777 Portugal 80 08 12370 Republic of Korea 82 2 528 5299 Russia amp CIS 7 495 7484900 South Africa 27 11 254 8360 Spain 34 901 988 054 Sweden 020 08 80371 Switzerland 41 52 675 3777 Taiwan 886 2 2722 9622 United Kingdom amp Eire 44 0 1344 392400 USA 1 800 426 2200 For other areas contact Tektronix Inc at 1 503 627 7111 Updated 15 September 2006 Our most up to date product information is available at www tektronix com cc go amp m Product s are manufactured in ISO registered facilities Product s complies with IEEE Standard 488 1 1987 RS 232 C and with Tektronix Standard Codes and Formats Copyright 2006 Tektronix All rights reserved Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supersedes that in all previously published mater
4. Subview Spectrum Main view Measurement Result gt Screen layout to identify analysis view locations as described in chart at left 6 RSAS3300A Series www tektronix com rsa Measurement Speed Screen Update Rate 2 MHz Span Auto RBW 19 4 s Remote Measurement Rate and GPIB Transfer Rate 2 MHz span auto RBW spectrum data 1 87 waveforms s or 6 000 samples s RF Center Frequency Switching Time 10 ms for 10 MHz frequency change 500 ms for 3 GHz frequency change Traces Displays Detectors Traces Two traces Spectrum Analyzer mode Displays Up to three time correlated user selected displays Detector RMS Trace Types Normal RMS Average Max Hold Min Hold Display Detection Max Min Max Min Modulation Analysis Analog AM Minimum Input Level 40 dBfs typical PM Minimum Input Level 40 dBfs typical PM Scale Max Min 180 FM Minimum Input Level 40 dBfs typical Range Span 2 from center frequency Demodulation Accuracy Analog AM 10 dBfs signal input at CF 10 to 60 modulation depth 2 PM 10 dBfs signal input at CF 3 FM 10 dBfs signal input at CF 1 of span Real Time Spectrum Analyzers gt RSA3303A e RSA3308 e WCA230A e WCA280A RF Performance Frequency Frequency Range RSA3308A WCA280A DC to 8 GHz RSA3303A WCA230A DC to 3 GHz Center Frequency Setting Resolution 0 1
5. 0 C Warm up Time 20 min Altitude Operating Up to 3000 m 10 000 ft Non operating Up to 12 000 m 40 000 ft Safety and EMI Compatibility UL 61010 1 CSA C22 2 No 61010 1 04 IEC61010 Second Edition Self Declaration Low Voltage Directive 73 23 EEC amended by 93 68 EEC EN61010 1 2001 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use EC Council EMC Directive 89 336 EEC amended by 93 68 EEC EN61326 1 1997 Product Family Standard for Electrical Equipment for Measurement Control and Laboratory Use EMC Requirements Electromagnetic Compatibility Framework 1992 AS NZS 2064 1 2 Industrial Scientific and Medical Equipment Power Requirements 100 VAC to 240 VAC 47 Hz to 63 Hz Power Consumption 400 VA max Data Storage Internal HDD 40 GB USB port FDD Weight without options 19 kg 42 Ibs Dimensions Without bumpers and feet 215 mm H x 425 mm D x 425 mm W With bumpers and feet 238 mm H x 470 mm D x 445 mm W Calibration Interval 1 year Warranty 1 year GPIB SCPI compatible Real Time Spectrum Analyzers gt RSA3303A e RSA3308 e WCA230A e WCA280A gt Ordering Information WCA23OA WCA280A Real Time Spectrum Analyzer WCA230A DC 3 GHz Real Time Spectrum Analyzer WCA280A DC 8 GHz Includes User manual programmer s manual power cord BNC N adapter USB keyboard and mouse
6. 0480 s 320 ms 320 ys 1 kHz 1 6 kS s 12800 s 40960 s 640 ms 640 us 500 Hz 800 kS s 25600 s 81920 s 1 28 s 1 28 ms 200 Hz 320 S s 64000 s 204800 s 3 28 3 2 ms 100 Hz 160 S s 128000 s 409600 s 6 45 6 4 ms RSAS3300A Series www tektronix com rsa 5 Real Time Spectrum Analyzers gt RSA3303A RSA3308 e WCA230A WCA280A Analysis related Measurement Functions by Mode Mode Measurements SA Channel Power Adjacent Channel Power Ratio Occupied Bandwidth Emission Bandwidth Carrier to Noise Ratio Carrier Frequenc RTSA Channel Power Adjacent Channel Power Ratio Occupied Bandwidth Emission Bandwidth Carrier to Noise Ratio Carrier Frequency Time IQ vs Time Power vs Time Frequency vs Time CCDF Crest Factor Pulse Measurements Pulse Width Pulse Peak Power On Off Ratio Pulse Ripple Pulse Repetition Interval Duty Cycle Pulse Pulse Phase Channel Power OBW EBW Frequency Deviation Min pulse length 20 samples Max pulse length 360 000 samples Analog Demod IQ vs Time AM Depth FM Deviation PM Deviation Pulse Spectrum SSS Views by Mode gt emen Mode Views Overview Subview SA Spectrum area Area na SA Spectrogram Spectrum Spectrogram ir RTSA Spectrum Spectrogram Time Overview Power vs Time Spectrogram Main View xe Subview Spectrum Selection Main view Measurement Result Selection ee Analog Demod Overview Power vs Time Spectrogram
7. 22 0 V Low 0 4 V Capture related Real time Capture Bandwidth 15 MHz RF 20 MHz baseband 20 MHz using Opt 03 IQ inputs A D Converter 51 2 MS s 14 bits Minimum Acquisition Length in RTSA Time Demod Modes 1024 samples Maximum Acquisition Length in RTSA Time Demod Modes 16 384 000 samples 65 636 000 samples Opt 02 Acquisition Length Setting Resolution in RTSA Time Demod Modes Acquisition Memory Size 16 4 Msamples 65 6 Msamples Opt 02 Block Size number of frames 1 to 16 000 1 to 64 000 Opt 02 Real Time Spectrum Analyzers gt RSA3303A RSA3308 e WCA230A WCA280A N Memory Depth Time and Maximum Time Resolution Span Sample Rate Record Length Record Length Spectrum Frame Max Time For and Q Opt 02 Time Resolution 20 MHz Baseband 25 6 MS s 0 64 s 2 56s 40 ys 40 ns 15 MHz 25 6 MS s 0 64 s 2 56 S 40 us 40 ns 10 MHz 12 8 MS s 1 28 s NIIS 80 us 80 ns 5 MHz 6 4 MS s 2 56 S 10 24 s 160 us 160 ns 2 MHz 3 2 MS s 6 45 20 48 s 320 ys 320 ns 1 MHz 1 6 MS s 12 8 s 40 96 s 640 us 640 ns 500 kHz 800 kS s 25 6 s 81 92 s 1 28 ms 1 25 us 200 kHz 320 kS s 64s 204 8 s 3 2 ms 3 2 US 100 kHz 160 kS s 128 s 409 6 s 6 4 ms 6 4 us 50 kHz 80 kS s 256 s 819 25 12 8 ms 12 8 us 20 kHz 32 kS s 640 s 2048 s 32 ms 32 us 10 kHz 16 kS s 1280 s 4096 s 64 ms 64 us 5 kHz 8 kS s 2560 s 8192 s 128 ms 128 us 2 kHz 3 2 kS s 6400 s 2
8. Hz Frequency Marker Readout Accuracy Baseband RE x MF 0 001 x Span 0 2 Hz Frequency Marker Readout Accuracy RF RE x MF 0 001 x Span 2 Hz Span Accuracy 1 bin RBW Filter Bandwidth Accuracy 0 1 Reference Frequency Aging per Day 1 x 10 after 30 days of operation Aging per Year 1x 107 after 30 days of operation Temperature Drift 1 x 1077 10 C to 40 C Total Frequency Error 2 x 107 within one year of calibration Reference Output Level gt 0 dBm External Reference Input 10 MHz 10 dBm to 6 dBm Frequency Span Range Spectrum Analyzer Mode 50 Hz to 3 GHz start frequency 240 MHz 0 Hz to 40 MHz stop frequency 40 MHz Range Real Time Spectrum Analyzer Mode 100 Hz to 15 MHz RP 0 Hz to 20 MHz baseband Resolution Bandwidth Range 1 Hz to 10 MHz automatically selected or user defined Accuracy Within 6 0 0 1 Shape Characteristic Gaussian with 5 1 shape factor 3 60 dB Rectangular Nyquist Root Nyquist shapes may also be selected 3 RE Reference Frequency Error 4 MF Marker Frequency Hz RSAS3300A Series www tektronix com rsa Minimum Settable RBW Extended Resolution ON Frequency RBW Span gt 2 GHz 100 kHz 1 GHz Span lt 2 GHz 50 kHz 500 MHz Span lt 1 GHz 20 kHz 20 MHz Span 500 MHz 10 kHz 500 kHz Span x20 MHz 1 kHz 200 kHz lt Span l
9. Panel LAN Interface Ethernet 10 100Base T Standard Serial Interface USB 1 1 2 ports VGA Output VGA compatible 15 D sub 9 Real Time Spectrum Analyzers gt RSA3303A RSA3308 e WCA230A WCA280A gt Residual Response Frequency Spec 1 to 40 MHz Span 20 MHz Ref Lvl 30 dBm RBW 100 kHz 93 dBm 0 5 to 3 5 GHz Span 3 GHz Ref Lvl 30 dBm RBW 100 kHz 90 dBm 3 5 to 6 5 GHz Span 3 GHz Ref Lvl 30 dBm RBW 100 kHz 85 dBm 3 5 to 8 GHz Span 3 GHz Ref Lvl 30 dBm RBW 100 kHz 85 dBm gt Spurious Response with Signal Frequency Spec 0 MHz Span 10 MHz Ref Lvl 0 dBm RBW 50 kHz Signal Frequency 25 MHz Signal Level 5 dBm 73 dBc 2 GHz Span 10 MHz Ref Lvl 0 dBm RBW 50 kHz Signal Frequency 2 GHz Signal Level 5 dBm 73 dBc 5 GHz Span 10 MHz Ref Lvl 0 dBm RBW 50 kHz Signal Frequency 5 GHz Signal Level 5 dBm 70 dBc 7 GHz Span 10 MHz Ref Lvl 0 dBm RBW 50 kHz Signal Frequency 7 GHz Signal Level 5 dBm 70 dBc 5 Frequency gt 3 MHz available on RSA3308A WCA280A only gt VSWR RF ATT gt 10 dB Frequency Spec Typical 300 kHz to 10 MHz 141 10 MHz to 3 GHz 1 31 2 5 GHz 1 41 7 5 GHz 1 81 10 RSA3300A Series www tektronix com rsa General Characteristics Temperature Operating 10 C to 40 C Storage 20 C to 6
10. Real Time Spectrum Analyzers gt RSA3303A RSA3308 WCA230A WCA280A Features amp Benefits Trigger Tektronix Exclusive Frequency Mask Trigger Makes Event based Capture of Transient RF Signals Easy By Triggering on Any Change in the Frequency Domain d c ce c e c ce c Capture All Input Signals up to 15 MHz Spans Are Seamlessly Captured Into Memory Long Record Length Enables Complete Analysis Over Time Without Making Multiple Acquisitions i i x i i Interfaces With TekConnect Trigger Capture Analyze Radar 3G or Other Time varying RF Signals probes for RF and Baseband Get Fast Resolution to Complex a continuous time record of changing Probing Problems with Trigger Capture RF events and enables time correlated Anys m and Analysis Tools analysis in the frequency time and g of Time varing Transient ic 2 RF Signals See the frequency and amplitude of your rigauaton domains You get the iung Spectrogram Provides RF signal change over time in a single tionality of a vector signal analyzer a wide Revealing Picture of RF Signal i nm band t lus th Frequency and Amplitude view With only a single acquisition the and spectrum anayzer plus the unique Behavior Over Time Not RSA3300A and WCA200A Series Real trigger capture analyze capability of cct Anal a Time Spectrum Analyzers RTSA capture RTSA in one transportable package Multi domain Analysis Enables Fast Compl
11. ation 10 MHz 5i Measurement Range l Point RF at 100 MHz 20 dBm signal 0 dB ATT 2G N50 Displayed average noise level to MAX safe input 20 C to 30 C 0 5 dB Input Attenuator Range Reference Level Setting Range 3 en I50 RF Baseband Input 0 dB to 50 dB 5 dB step 7 GHz 142 IQ Input Opt 03 0 dB to 30 dB 10 dB step Input Attenuator Setting Uncertainty 0 5 dB at 50 MHz Maximum Safe Input Level Average Continuous RF band RF ATT 210 dB 30 dB MAX DC Voltage 0 2 V RF 5 V Baseband 5 V IQ input with Opt 03 Log Display Range 10 udB div to 10 dB div Linear Display Scale 10 divisions Linear Display Units dBm dBuV V Watts Hz for FM Demod Degrees for PM Demod Marker Readout Resolution Log 0 01 dB Marker Readout Resolution Linear 0 001 pV 1 dB step RF 50 dBm to 30 dBm 5 dB step Baseband 30 dBm to 20 dBm 5 dB step IQ 10 dBm to 20 dBm Reference Level Accuracy 10 dBm to 50 dBm at 100 MHz 10 dB ATT 20 C to 30 C 0 2 dB Level Linearity in Display Range 0 2 dB spec 0 12 dB typical Spurious Response 1 dB Compression RF ATT 0 dB 2 GHz CF 2 dBm 3 Order Inter modulation Distortion Ref Level 5 dBm RF ATT adjusted for optimum total signal power 7 dBm CF 2 GHz 74 dBc 2 Harmonic Distortion 30 dBm tone at input mixer 10 MHz to 1750 MHz 56 dBc typical
12. de for RSA3300A Series RSA3UP IF Installation labor for RSASUPxx no calibration required RSA3UP IFC Installation labor for RSASUPxx with calibration RSA3SASW USB Stand alone Software Key 9 Specifications for Options 21 through 40 can be found in the Real Time Spectrum Analyzer Software Options datasheet on www tektronix com rsa Contact Tektronix ASEAN Australasia 65 6356 3900 Austria 41 52675 3777 Balkan Israel South Africa and other ISE Countries 41 52 675 3777 Accessories RTPA2A Probe Adapter box for TekConnect Probes 119 4146 00 RF Near Field Passive Probe Kit International Power Plugs Opt AO North America power Opt A1 Universal Euro power Opt A2 UK power Opt A3 Australia power Opt A4 North America power 240 V Opt A5 Switzerland power Opt A6 Japan power Opt A10 China power Opt A99 No power cord Service Options Opt C3 Calibration Service 3 years Opt C5 Calibration Service 5 years Opt D1 Calibration Data Report Opt D3 Calibration Data Report 3 years with Opt C3 Opt D5 Calibration Data Report 5 years with Opt C5 Opt R3 Repair Service 3 years Opt R5 Repair Service 5 years Language Options Opt LO English User Programmer manual Opt L5 Japanese User Programmer manual Belgium 07 81 60166 Brazil amp South America 11 40669400 Canada
13. eal Time Spectrum Analyzers RTSA by offering additional tools to make debugging today s high performance electrical designs easier Using the RTPA2A with Tektronix RTSA design engineers can benefit from Tektronix industry leading active and differential probes to measure signals on SMD pins or other challenging circuit features gt Characteristics Trigger related Trigger Mode Free run triggered by acquisition Triggered triggered by event Single or Continuous Trigger Event Source Power span BW Frequency Mask Opt 02 External Pre Post trigger Setting Trigger position settable within 0 to 100 of total acquisition length Trigger Marker Position Timing Uncertainty Power and External Trigger 2 sample points Frequency Mask Trigger Opt O2 Mask Resolution 1 bin Level Range 0 dBfs to 60 dBfs at 10 dB div vertical scale Bandwidth Up to 15 MHz Start frequency 220 MHz Up to 20 MHz Start frequency lt 20 MHz Mask Shape User defined Minimum Horizontal Mask Setting Resolution 0 296 of span Uncertainty 2 frames 2 dBfs dB relative to full scale 4 RSAS3300A Series www tektronix com rsa Power Trigger Level Range 0 dBfs to 40 dBfs External Trigger Threshold Voltage 1 5 V to 1 5 V Threshold Voltage Setting Resolution 0 1 V Input Impedance gt 2 KQ Trigger Output Voltage Output Current 1 mA High
14. esolution spectrogram reveals transient signal behavior that translates to rapid problem solving Here 500 kHz sidebands are revealed as part of the transient behavior of a hopping signal as it Frequency Span Inp Modulation Type GMSK EDGE Standard GSM900 UL Return to First Burst Mag Err Analyze trom Selected Burst Phase Err TS Code Filtering Freq Err Origin Offset TS Code 7 off 012 345 6 7 ISM EDGE Modulation Accuracy P Time correlated multi domain view provides a new level of insight into design or operational problems not possible with conventional analysis solutions switches frequencies Trigger Patented 15 MHz bandwidth Frequency Mask Trigger FMT makes it easy to capture transient low duty cycle or other difficult to capture signals An FMT mask is simply configured using a mouse and it can be set up for one or many frequency bands within an analysis span FMT can monitor for signal appearance disappearance or change in amplitude frequency bandwidth spectral shape and more all while the instrument user is working on another task A Power Trigger working in the time domain and at any real time analysis span can be armed to monitor for a user set power threshold to be crossed during a moment in time A power detector determines total power of all signals in a span which is compared to the user set threshold Capture Capture once make multiple measure ments as
15. ete Signal Analysis in Frequency Time Code and Modulation Domains Without Making Multiple Measurements Simple Capture and Analysis on RFID Interrogator and Response Signals Comprehensive Pulse Measure ment Suite General Purpose Digital Modulation Analysis Spectrum Analyzer View for Traditional Wide Band Signal Analysis 3G Measurement Versatility with W CDMA cdma2000 1X EVDO HSUPA HSDPA TD SCDMA RF and Modulation Analysis WCA200A only Signal Source Analysis Simplifies Phase Noise Jitter and Frequency Settling Measurements Applications System Integration of 3G and Other RF Systems Radar and Pulsed RF Signal Characterization RFID System Development and Troubleshooting General Purpose Phase Noise and Jitter Signal Analysis Characterization of Interfering or Unknown Signals in Spectrum Monitoring and Surveillance Troubleshooting RF Components Modules or Systems Getting Answers to Elusive EMI Diagnostic Problems 1 20 MHz bandwidth at Baseband Tektronix Enabling Innovation Real Time Spectrum Analyzers gt RSA3303A RSA3308 e WCA230A e WCA280A Tektronix RSA 3408A 10 7 2004 10 EE Spectrum Length Spectrum Interval 1 2 Marker X Positic Hz Markers Off Snge Deta Reference Cursor to Marker X Reference Cursor off Selected Marker off 2 4 GHz er RealTime S A Measurement Off 9 Marker X Position GHz P High r
16. ial Specification and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc All other trade names referenced are the service marks trademarks or registered trademarks of their respective companies 10 06 HB WOW 37W 18864 2 Tektronix P Enabling Innovation ES
17. ndividual spectra as close as 40 ns providing an intuitive view of signal changes over time ideal for such things as frequency hopping pulsed signals modulation switching settling time bandwidth changes relative timing of appearing and intermittent signals The RTSAs introduce analysis capabilities that advance productivity for engineers working on components or in RF system design integration and performance verification or operations engineers working in networks spectrum moni toring or surveillance Real Time Spectrum Analyzers gt RSA3303A RSA3308 e WCA230A WCA280A N gt Example Applications Benefiting from Key RSA3300A and WCA200A Capabilities Analysis Feature RF Communications Cellular Devices Radar Pulsed Signal Surveillance RFID Systems Transmission Spectrum Monitoring Hi res Spectrogram X X X X X Multi domain Correlation X X X X X Cellular Standards Analysis Multiple Options X X Advanced Measurement Suite Opt 21 AM FM PM Analysis Pulsed RF Signal Analysis Pulse Spectrum AM AM AM PM and 1 dB Compression Opt 21 X X X gt lt gt lt x gt lt gt lt gt lt gt lt gt lt gt lt RSA3300A Series www tektronix com rsa 3 Real Time Spectrum Analyzers RSA3303A e RSA3308 e WCA230A e WCA280A TekConnect Probe Adapter for Real Time Spectrum Analyzers The RTPA2A Real Time Probe Adapter extends the capabilities of the R
18. needed All signals in a real time analysis span including transients low duty cycle and other difficult to measure events are captured together into deep memory where signal data can be accessed at the user s convenience Record lengths vary depending on span Selected up to 2 56 s at 15 MHz span 40 96 s at 1 MHz span or 4096 s at 10 kHz span with Deep Memory Opt 02 Real time capture of small signals is enhanced by 74 dBc third order IM plus very good phase noise performance and sensitivity A solid performance front end serves not only real time and wide band spectrum analysis modes but also on board vector signal analysis functionality The RTPA2A Real Time Probe Adapter extends the capabilities of the Real Time Spectrum Analyzers RTSA by offering additional tools to make debug ging today s high performance electrical designs easier Using the RTPA2A with Tektronix RTSA design engineers can benefit from Tektronix industry leading active and differential probes to measure signals on SMD pins or other chal lenging circuit features 2 RSA3300A Series www tektronix com rsa Analyze Time correlated multi domain analysis provides engineers with unique insight into time varying signal behavior resulting in fast analysis and problem solving Time correlated measurements can be made across the frequenoy time and modulation domains The analysis display called Spectrogram has the ability to overlap i
19. reamp 100 MHz 3 GHz 20 dB gain 6 5 dB Noise Figure at 2 GHz typical WCA2UP 1R Rackmount kit upgrade for WCA200A Series WCA2UP IF Installation labor for WCA2UPxx no calibration required WCA2UP IFC Installation labor for WCA2UPxx with calibration RSA3SASW USB Stand alone Software Key 8 Option 23 and Option 27 are required for 3GPP Release 6 HSUPA Analysis in addition to Option 40 RSA3300A Series www tektronix com rsa 11 Real Time Spectrum Analyzers RSA3303A RSA3308 e WCA230A WCA280A RSA3303A RSA3308A Real Time Spectrum Analyzer RSA3303A DC 3 GHz Real Time Spectrum Analyzer RSA3308A DC 8 GHz Includes User manual programmer s manual power cord BNC N adapter USB keyboard and mouse Product Options Opt 02 65 5 MSample Deep Memory Frequency Mask Trigger Opt 03 IQ Differential IQ Inputs Opt 21 Advanced Measurement Suite Software Opt 1A External Preamp 100 MHz to 3 GHz 20 dB gain 6 5 dB Noise Figure at 2 GHz typical Opt 1R Rackmount kit Opt SASW USB Stand alone Software Key Upgrades RSA3UP 02 65 5 MSample Deep Memory Frequency Mask Trigger RSA3UP 03 IQ Differential IQ Inputs RSA3UP 21 Advanced Measurement Suite customer installable WCA2UP 1A External Preamp 100 MHz to 3 GHz 20 dB gain 6 5 dB Noise Figure at 2 GHz typical WCA2UP 1R Rackmount kit upgra
20. t 500 kHz 500 Hz 100 kHz Span lt 200 kHz 200 Hz 50 kHz Span 100 kHz 100 Hz 20 kHz Span x50 kHz 50 Hz 10 kHz Span x20 kHz 20Hz 5 kHz Span x10 KHz 10Hz 2 kHz Span lt 5 kHz 5Hz 1 kHz Span lt 2 kHz 2Hz 100 Hz Span 1 kHz 1Hz Noise Bandwidth Range RTSA Mode 313 18 MHz to 400 87 kHz FFT Performance Number of Samples per Frame 64 to 8192 65 536 samples per frame extended resolution Window Types Rectangular Parzen Welch Sine Lobe Hanning Sine cubed Sine to the 4 Hamming Blackman Rosenfield Blackman Harris 3A Blackman Harris 3B Blackman Harris 4A Blackman Harris 4B FlatTop 7 Real Time Spectrum Analyzers gt RSA3303A RSA3308 e WCA230A e WCA280A Stability gt Noise Sidebands dBc Hz UN Offset At 1 GHz CF At 2 GHz CF At 6 GHz CF Spec Typical Spec Typical Spec Typical 1 kHz 100 103 96 99 87 90 10 kHz 105 108 104 107 104 107 20 kHz 105 108 105 108 105 108 30 kHz 105 108 105 108 105 108 100 kHz 112 115 112 115 112 115 1 MHz 132 135 132 135 128 131 5 MHz 135 138 135 138 130 133 7 MHz 135 138 135 138 130 133 Residual FM Absolute Amplitude Accuracy at Calibration Displayed Average Noise Level 2 Hzy g typical Point Baseband at 25 MHz 10 dBm signal Specified dBm Hz 0 dB ATT 20 C to 30 C 0 3 dB Frequency Spec Amplitude Absolute Amplitude Accuracy at Calibr

Download Pdf Manuals

image

Related Search

File filezilla files file explorer filevine login file manager filecr filevine filehippo filemaker file converter files folder file transfer file compressor filezilla download file sharing filet mignon filemaker pro file explorer options file associations settings files app filezilla server filehorse file upload filezilla client file explorer windows 10

Related Contents

d~اضةًٍ - TechSmart  Philips SPA4270BT  OFLOPS: User manual  Panel modular de policarbonato celular PROTEGIDO U.V.  5 Enterprise Report Manager - GRUPO MULTISERVICIOS GLOBALES  halsey taylor owners manual manual del propietario halsey taylor    Hampton Bay 17195 Installation Guide  Terms  Display - Services  