Upgrading Flow Computer Firmware
Contents
1. e 52 0001 0005 Rev C A Omni Page 9 of 16 TB 980803C Upgrading Flow Computer Firmware 21 22 23 24 25 26 If the EPROM Revision number and Checksum are correct verify if both the S Ware Software and H Ware Hardware columns read Y Yes for all the installed modules before proceeding any further Scroll up and down the screen in the previous step by using the W N arrow keys to view installed modules If both columns read Y proceed to Step 25 If not proceed to step 22 If one or more of the installed modules reads N No under the S Ware Software and or H Ware Hardware columns press Prog Setup Enter Enter the following will be displayed MISC SETUP Password Maint Y Check Modules Y Config Station Y Different screens will be displayed each time you press enter before you reach the previous screen Move the cursor down by pressing the V key to Check Modules MISC SETUP Password Mai nt Y Check Modules Y Config Station Y Press Enter and a screen similar to the following will be displayed ule S Ware H Ware Y y y N Scroll down by pressing repeatedly the V key to Update S Ware and press Alpha Shift Y Enter to enter Y for Yes Module S Ware H Ware D 1 Y N S 1 N Y Update S Ware y You will be prompted to enter your password Also enter Y to answer OK if cautioned that updating the software will cause
2. Omni Page 4 of 16 TB 980803C Upgrading Flow Computer Firmware Print the configuration file from OMNICOM to your PC or network printer by using File Print and selecting your print option of LPT1 or LPT2 You must have your MS Windows virtual printer captured to an LPT port to print from OMNICOM for DOS Contact your IT department for assistance Close the old OMNICOM and start the new OMNICOM for DOS Create a new file in OMNICOM by selecting File New and entering the file name When prompted for the EPROM version number of the new file to create select the version number that corresponds to the NEW EPROMs you will be installing not the version of the EPROMs currently installed 8 Execute Steps 3 and 4 as shown 9 Verify all settings indicated in your new configuration file with the configuration file printout from Step 5 and make any necessary adjustments to these settings that are appropriate for your particular application 10 Close OMNICOM by selecting Exit from the File menu You will be prompted on whether to save the configuration file and each of the report templates Answer Yes to all 11 Go to the section in this technical bulletin entitled Replace the Central Processor module CPU and EPROM Chips l START y Xe z A i A Perform a Rese alng ene NO all kr oe Privileged Password from older xx 74 N a s a OMN again and EPROMS to newer gt eyp
3. I Os after you have completed the EPROM upgrade and transmitted the configuration file Volume 1 System Architecture and Installation of the User Manual for more information If the flow computer does not power up to the Status screen go to the Troubleshooting Tips section of this Technical Bulletin 52 0001 0005 Rev C Omni Page 7 of 16 TB 980803C Upgrading Flow Computer Firmware 68 6001 Program Program EPROM RAM System Watchdog J3 In Enabled J3 Out Disabled Always Enabled Figure 3 Layout of Central Processor Module Showing Location of EPROM ICs and Jumpers J1 J2 and J3 Resetting RAM IMPORTANT After Replacing CPU Module or EPROMs and Before Transmitting the Configuration file You may be required to perform the Check I O Modules procedure refer to related section in this bulletin before transmitting the configuration file to the upgraded flow computer and calibrating the analog I Os Also you must reset RAM as expressed in this Technical Bulletin before transmitting the configuration file These procedures must be performed whether or not a corresponding message is displayed on the front panel LCD screen of the flow computer Failure to do so may void the warranty and cause future problems and unpredictable results with your flow computer Program Mode Pressing the Prog key will activate the Program Mode While in this mode the Program LED above the k
4. Ports menu z 52 0001 0005 Rev C Omni Page 15 of 16 TB 980803C Upgrading Flow Computer Firmware DOCUMENT REVISION HISTORY DOCUMENT INITIAL RELEASE DATE cccccccccccccccceeeceeeeeeeeeeeeeeees 03 May 2003 REVISION DATE PURPOSE CHANGE REQUEST A 03 May 2003 Maintained on the web Initial release B 05 May 2003 Maintained on the web C 24 February 2009 DCR 090028 52 0001 0005 Rev C Y Omni Page 16 of 16
5. digits press 0 Enter To set totalizer rollover to 8 digits press 1 Enter Setting Volume and Mass Totalizer Resolution Gross and net volume and mass totalizer values can be expressed with up to three 3 decimal places To set the number of decimal places for totalizer resolution press the corresponding number key 0 1 2 or 3 decimal places where 0 Klbs 1 1000lbs 2 10lbs 3 lbs Press the Enter key All firmware revisions except for Version 20 56 provide Mass in pounds Help for Number of Digits and Decimal Place Settings You can view the Help in OMNICOM under Factor Setup amp Sys Constants by highlighting each of the fields Then use F1 for detailed explanation of each of your choices However DO NOT set these options via OMNICOM Context sensitive help is also available via the OMNI front panel keypad by pressing the Help key same as the Enter key twice within one 1 second while the cursor is at the entry you want to set Press PROG key once to exit Help e 52 0001 0005 Rev C AN Omni Page 11 of 16 TB 980803C Upgrading Flow Computer Firmware It is strongly recommended that you set these resolutions NOW because you will not be able to change these settings after configuring your flow computer or during flow operations without resetting to zero all your totalizers Special Instructions If Upgrading from Revision 20 56 Firmware Version 20 56 EPROMs provide Mass in hundreds o
6. the new EPROM version Also verify in OMNICOM that Use Default Report Templates under Printer Setup is set to No when using custom report templates NOTE When using 74 firmware In the Configure Reports menu of OMNICOM for Windows instead of having a global setting for all four 4 reports i e SnapShot Batch End Daily and Prove you are now allowed to have a mix of customized and default report templates Ensure that you check or uncheck the appropriate box for each report template based on your preference Unable to Complete a Prove Sequence Sometimes you are unable to get through a prove sequence after an EPROM upgrade Open up the deviation percentages in the Prover Setup menu to establish an initial prove sequence Also ensure that you have selected the option NOT to implement the prove meter factor Once a prove sequence has completed successfully you can tighten up the deviation percentages to what you had set before the EPROM upgrade If you were previously auto implementing a prove meter factor you can change the setting back in the Prover Setup menu after a successful prove sequence NOTE In OMNICOM for Windows these settings are found in the Configure Prover menus 52 0001 0005 Rev C U Omni Page 14 of 16 TB 980803C Upgrading Flow Computer Firmware OMNICOM Unable to Communicate with the Flow Computer IMPORTANT A omnicom for DOS and MS Windows XP or MS Windows 2000 If you are experiencing problems communica
7. unit is AC powered To avoid electrical shock which could be fatal It is imperative that you remove all power before opening and disassembling the flow computer and take any other necessary precautions Only qualified technicians should work on any internal circuitry OMNI Flow Computers Inc is not responsible for personal injuries or accidents that may occur when working on flow computer circuitry Before removing any circuit boards from the flow computer the following must be observed e Personal Safety Although most of the internal circuits are powered by relatively low voltages dangerous AC voltages are present on the power supply module and ribbon cable when the unit is AC powered For this reason it is important to remove all power before disassembling the flow computer e Static Electricity Static electricity can be generated simply by moving around on certain surfaces or wearing certain types of clothing The flow computer s printed circuits can be damaged by this static electricity Take approved static device handling precautions when working on the flow computer CAUTION A Static electricity can damage flow computer circuitry Take approved static device handling precautions when working on the flow computer 52 0001 0005 Rev C Omni Page 3 of 16 TB 980803C Upgrading Flow Computer Firmware rag Upgrading lt to xx 73 or older DOS i EPROMs Sf Use your existing OmniCom for DOS to Retrie
8. your screen and select the site and flow computer you would like to connect to 38 Transmit OMNI Configuration Data and then the Custom Report Templates NOTE If using OMNICOM for Windows the custom report templates are automatically transmitted for you when transmitting the configuration file assuming they exist on your PC and the names are associated with the transmitted configuration file 39 While in the online mode check all of your configuration settings to ensure they are correct 40 Calibrate your analog I Os if you are required to do so For more information on calibrating analog I O refer to Volume 1 Chapter 8 of the User Manual Returning the Old EPROMs Remember to use the Business Reply Label supplied with your new EPROMs If you have not yet completed your EPROM Upgrade Form please do so now and return along with the old EPROMs to OMNI Flow Computers Inc Troubleshooting Tips Keypad is Locked Keypad is locked i e Program Lockout message is displayed when attempting to make changes via the keypad 1 Pull out the chassis and locate the Program Enable Lock switch located behind and towards the bottom of the keypad assembly Move the switch to the Enable position Proceed as follows if keypad is locked i e not functioning CAUTION Pressing the reset switch will cause you to lose approximately 1 5 seconds of flow Therefore it is recommended that you stop flow before pressing the reset switch It
9. 000 6000 Firmware to DOS xx 73 or older EPROMs Instructions OMNICOM for DOS Users If upgrading to 73 or older EPROMs before removing the Central Processor Module CPU or old EPROMs you must install the new version of OMNICOM for DOS Configuration PC Software supplied with your new CPU or EPROMs and use this new version to retrieve the configuration file from the flow computer Installing New OMNICOm for DOS PC Configuration Software NOTE Using OMNICOM Help Context sensitive help is available by pressing the F1 key on your PC keyboard when running OMNICOM 1 With the old EPROMs still in the flow computer install the new OMNICOM for DOS software on your PC from the diskette CD shipped with the CPU or EPROMs The diskette CD label provides installation instructions Do not install to the same directory as a previously installed version of OMNICOM for DOS 2 Start the old version of OMNICOM for DOS and retrieve the configuration and custom report templates from the flow computer 3 Receive the configuration file from the OLD set of EPROMs installed in the flow computer by using Online Start Comm and selecting Receive OMNI Configuration Data 4 Subsequently receive ALL the custom report templates by selecting Receive Report Templates within the Online Start Comm menu As a precautionary measure this should be done regardless of whether or not custom report templates are being used in the OMNI 52 0001 0005 Rev C
10. 1 Recommended Procedure for Upgrading OMNI 3000 6000 Firmware to DOS xx 73 or older EPROM S oree ea aar a a a aR lah E A EE cane aa a 4 Figure 2 Recommended Procedure for Upgrading OMNI 3000 6000 Firmware to Windows XC 74 ERP ROMS EE A E 5 Figure 3 Layout of Central Processor Module Showing Location of EPROM ICs and Jumpers SN SOP ANGUS ERS AES E E EAEE AA tg ac EA AAA EEE SEE SNT 8 52 0001 0005 Rev C Y Omni Page 2 of 16 TB 980803C Upgrading Flow Computer Firmware Scope This Technical Bulletin is applicable to all firmware revisions of OMNI 6000 OMNI 3000 Flow Computers The information contained in this Technical Bulletin is targeted to qualified professionals only Abstract Upgrading OMNI Flow Computer firmware allows users to incorporate new features and increase the capabilities of their flow metering system application To upgrade your flow computer firmware you will need to perform certain critical steps such as e Install the new version of OMNICOM Configuration PC Software e Save the flow computer configuration file and custom report templates e Replace Central Processor Module or EPROM chips e Reset RAM e Set the number of digits and decimal places for totalizers and correction factors e Download and adjust flow computer configuration file and report templates Safety Considerations DANGER A Electrical Shock Hazard Dangerous AC voltages are present on the power supply module and ribbon cable when the
11. Last Updated 24 February 2009 TB 980803C Technical Bulletin Upgrading Flow Computer Firmware OMNI FLOW COMPUTERS INC ps 1 e 12620 West Airport Boulevard Suite 100 US Omni Sugar Land Texas 77478 United States of America Phone 281 240 6161 Fax 281 240 6162 www omniflow com 52 0001 0005 Rev C TB 980803C Upgrading Flow Computer Firmware NOTE User Manual Reference This Technical Bulletin complements the information contained in Volume 1 applicable to all firmware revisions After replacing the CPU Module of EPROMS and before transmitting configuration files You must perform the Check I O Modules procedure and calibrate the analog I Os before transmitting the configuration file to upgrade the flow computer Also you must reset RAM as expressed in this Technical Bulletin before transmitting the configuration file These procedures must be performed whether or not a corresponding message is displayed on the front panel LCD screen of the flow computer Failure to do so may void the warranty and cause future problems and unpredictable results with your flow computer Table of Contents SCOPE nesses inasete coneda nen iter eauacethars Sratgida ade Uta tone dereedeus ab once band beenweesdeinnst A Setaquandtyiaey guaes 3 JAN OeII Ea 10 AEE EEEE E EE tusne aseaeduss A tasuaa sakes sake EE E E ecru 3 Safety Considerations eee aa a aa a A a e e psd eae Ee aar Aaaa E AENEA ge AANA CEES RANT sates 3 Instructions OMNICO
12. M for DOS Users sssssssesessnnesssrrrnersnrrrttrressrrrnnertnnntstntnnsstrnnnrrnnn ota meet 4 Installing New OmniCom for DOS PC Configuration Software iin ccretnceen cadet ands 4 Instructions OminiCom for Windows Users c c cicccliuaiethieneccc saxon edaeedinedetinaiees 6 Installing New OMNICOM for Windows PC Configuration Software f 6 Replacing the Central Processor Module CPU and EPROM Chips f 7 POPE Fr eaaa E maa a 8 Verifying and Updating Information of Installed Modules Check I O Modules a 9 Setting the Number of Digits and Decimal Places for Totalizers 11 Special Instructions If Upgrading from Revision 20 56 Firmware ssssssssssssesesssssssserrrrereeeee 12 Transmitting the Configuration File from OMNICOM to the Flow Computer 12 PROTON HN O E OMS a a chi el trade E uate 13 TOUDISSHOOING MAN AEAEE A AA E E E A tn aeeeneenenemets ce 13 Keypad SOC aos eset A A A nee es ae ares es 13 OMNI Display Does Not Come On After Resetting All RAM or OMNI Front Panel Display is 111 1 51212 Repay ORES TOS PFET TROT eMC ET TORRY SO PETIT IPE TON 13 Message Cannot Open File is Displayed when Trying to Transmit the Saved Report TOPAS TO A MIN ca adacca dea sepe octet nh TO 14 Incorrect Data In Printed Customized Reports i aecssessseessesssesseceresenevenenenesen 14 Unable to Complete a Prove Sequence a cacseeesssssseessssttsssssteessesseeesenssneeeesan 14 OMNICOM Unable to Communicate with the Flow Computer rrr 15 Figures Figure
13. RAM Data Invalid Reconfigure System Using OMNI as Initial Password 19 Press Status and a screen similar to the following will be displayed odule S Ware H Ware 1 Y Y 1 Y Y 1 Y Y 20 Scroll down by pressing repeatedly the W key to the end to display the Revision Number and EPROM Checksum Verify that these match with what you previously noted If they do not match and there is an EPROM Checksum alarm stop at this point and contact OMNI Technical Support Verifying and Updating Information of Installed Modules Check I O Modules IMPORTANT After Replacing the CPU Module or EPROMs and before transmitting the Configuration file You may be required to perform the Check I O Modules procedure refer to related section in this bulletin before transmitting the configuration file to the upgraded flow computer and calibrating the analog I Os Also you must reset RAM as expressed in this Technical Bulletin before transmitting the configuration file These procedures must be performed whether or not a corresponding message is displayed on the front panel LCD screen of the flow computer Failure to do so may void the warranty and cause future problems and unpredictable results with your flow computer Program Mode Pressing the Prog key will activate the Program Mode While in this mode the Program LED above the keypad is red To exit the Program Mode press the Prog key repeatedly until the Program LED goes off
14. ar configure a serial port for x 74 EPROMs Po communication with 4 a OmniCom for Windows Upgrading NO viS from xx 73 or older EPROMS to xx 74 EPROMs me Y Y Fa Using OmniCom N See Power Down The for Windows open Separate Omni and Remove your Configuration flowchart the Old EPROM s File saved in an related to earlier step Use OmniCom for xx 73 and DOS to Retrieve older Save and Print your EPROMs _ ___ Omni Configuration Install the new Y amp Custom Report EPROM s Install newest Templates OmniCom for Transmit Windows Configuration File Power Up the to the Omni Omni amp Enter the Install newest Privileged OmniCom for Password OMNI Windows Refer to 4 Troubleshooting Calibrate Analog id a O s if necessary Using the ener and check User OmniCom for Entered Data Retrieve configuration file Windows Import hesa coes veal settings and and custom report feature import and P oP propery Operation of the templates from Omni and then save the DOS Omi make any necessary configuration file dh gt changes to the settings and custom report Y Save your files templates j IMPORTANT iy Scroll down amp y N Perform a Reset END All RAM oe J Operation v v Figure 2 Recommended Procedure for Upgrading OMNI 3000 6000 Firmware to Windows xx 74 EPROMs 52 0001 0005 Rev C U Omni Page 5 of 16 TB 980803C Upgrading Flow Computer Firmware Instructions OMNICOM for Windows Users Be
15. et RAM as expressed in this Technical Bulletin before transmitting the configuration file These procedures must be performed whether or not a corresponding message is displayed on the front panel LC screen of the flow computer Failure to do so may void the warranty and cause future problems and unpredictable results with your flow computer If you are replacing ONLY the EPROM chips and NOT the CPU module reset all RAM in the OMNI via the front panel keypad If you will be replacing the entire CPU module DO NOT reset the RAM To reset RAM from the front panel keypad press Prog Setup Enter Enter Enter then type in your privileged password as prompted Scroll down by pressing the V key to the Reset All Ram prompt and answer Y to answer yes Answer Yes or OK to any warnings Refer to Step 6 for detailed instruction on resetting Ram Remove power from the OMNI Flow Computer and remove the CPU module Make note of the new EPROM version and checksum indicated on the label placed on the EPROM chips You will need this information later Either replace the old CPU module with a new CPU that has the new set of EPROMs or simply replace the old set of EPROMs with the new set After replacing or reinstalling the CPU module apply power to the OMNI Flow Computer Make a note of what your LCD screen displays when powering up If you receive a display indicating loss of calibration data you will need to calibrate your analog
16. eypad is lit red To exit the Program Mode press the Prog key repeatedly until the Program LED goes off 16 You will need to reset RAM before and after replacing EPROM chips If you will be replacing the entire CPU module reset RAM only AFTER replacing the CPU DO NOT reset the RAM before replacing When power is applied to the flow computer after replacing EPROM chips the following screen is displayed If the screen does not appear as shown go to the Troubleshooting Tips section of this Technical Bulletin RAM Data Invalid Reconfigure System Using OMNI as Initial Password Enter the key press sequence Prog Setup Enter Enter Enter the following screen will be displayed Different screens will be displayed each time you press enter before you reach the previous screen 52 0001 0005 Rev C U Omni Page 8 of 16 TB 980803C Upgrading Flow Computer Firmware 17 At the Privileged prompt enter the following key press sequence to use OMNI as the privileged password Alpha Shift Alpha Shift O M N I Enter The cursor will move down to the next entry PASSWORD MAI NTENANCE ivi OMNI 18 Scroll down by pressing repeatedly the V key to Reset All Ram and press Alpha Shift Y Enter for Yes PASSWORD MAI NTE Archive Run Y Reset All Total Reset All Ram The display will briefly go blank and the backlight will go off and come back on The following screen may reappear
17. f pounds If you want to continue receiving your Mass in hundreds of pounds press 1 Enter at the DecimalPlaces Mass entry 31 Exit the Program Mode when you are done by pressing the Prog key repeatedly until the Program LED above the keypad goes out This returns you to the Display Mode Transmitting the Configuration File from OMNICOM to the Flow Computer NOTE Program Mode Pressing the Prog key will activate the Program Mode While in this mode the Program LED above the keypad is lit red Te exit the Program Mode press the Prog key repeatedly until the Program LED goes off 32 In the Display Mode press Prog Setup Enter Enter to display the Misc Setup menu MISC SETUP Password Maint Y Check Modules Y Config Station Y Different screens will be displayed each time you press enter before you reach the previous screen 33 Scroll down by pressing repeatedly the VW key to Serial I O n Enter the number of the flow computer serial port to which your OMNICOM PC is connected and press Enter A screen similar to the following will be displayed SERI AL PORT 2 Baud Rate Number of Data Number of Stop 34 Scroll down to Modbus ID and then to Modbus Type and enter the corresponding settings indicated in the OMNICOM configuration file you saved and printed earlier Remember to press Enter after typing each setting IMPORTANT It is recommended that you select Modbus RTU mode
18. fore removing the Central Processor Module CPU or old EPROMs refer to Steps 1 and 2 to make a determination on exactly how to proceed Installing New OMNICOM for Windows PC Configuration Software NOTE Using OMNICOM Help Context sensitive help is available by pressing the F1 key on your PC 10 keyboard when running OMNICOM If you are upgrading from 73 or older ERPROMs to 74 EPROMs with the old EPROMs still in the flow computer use the old OMNICOM for DOS software on your PC to retrieve the OMNICOM configuration and custom report templates from the flow computer Skip to Step 4 for instructions on how to do this otherwise go to Step 2 if you are upgrading from 74 EPROMs to a newer release of 74 EPROMs If you are replacing 74 EPROMs with newer 74 EPROMs install the new OMNICOM for Windows from the CD or from whatever directory you saved the install executable file to if you received the new version of OMNICOM for Windows by other than CD media Using the new version of OMNICOM for Windows just installed on your PC retrieve the configuration from the OMNI and save it to your PC You should now skip to the section labeled Replacing the Central Processor Module CPU and EPROM Chips Receive the configuration file from the OLD set of EPROMs installed in the flow computer by using Online Start Comm and select Receive OMNI Configuration Data NOTE You must first create or open an existing file in OMNICOM for DOS bef
19. ile you retrieved in Step 8 but will have the following extensions e Snapshot Report Template TP1 e Batch End Report Template TP2 e Daily Report Template TP3 e Prove Report Template TP4 Using the File Save feature save the configuration file and custom report templates to the directory where you currently have OMNICOM for Windows installed in Example C OMNIFLOW OMNICOM ABC 020 52 0001 0005 Rev C Y Omni Page 6 of 16 TB 980803C Upgrading Flow Computer Firmware Replacing the Central Processor Module CPU and EPROM Chips CAUTION A when removing the CPU Module take extreme care not to bend or fold the membrane keypad ribbon cable too sharply or the metallic traces could be damaged Location of EPROM Chips The location of the EPROM chips on the CPU Module is shown in Figure 1 The EPROMs are the two 2 large 32 pin Integrated Circuits ICs or chips with labels marked U3 and U4 Note the position of the orientation notches at one end of each EPROM IMPORTANT Replacing EPROM Chips Ensure that all pins plug into there respective holes and that 11 12 13 none are bent After Replacing CPU Module or EPROMs and Before Transmitting the Configuration File You may be required to perform the Check I O Modules procedure refer to related section in the bulletin before transmitting the configuration file to the upgraded flow computer and calibrating the analog I Os Also you must res
20. is recommended that you stop flow before pressing the Reset Switch on the flow computer as it will cause you to lose approximately 1 5 seconds of accumulated flow Pressing and releasing this switch has the same effect as disconnecting power to the flow computer and then reapplying power 1 Press the spring loaded Reset switch located behind the LCD screen and towards the top of the keypad assembly OMNI Display Does Not Come On After Resetting All RAM or OMNI Front Panel Display is Blinking Proceed as if display is blinking or two rows of squares are displayed 1 Disconnect all power to the OMNI Remove the CPU Module located directly behind the keypad assembly Remove the four RAM chips in slots U5 through U8 on the CPU board Reinsert them inserting U5 last taking care not to bend any pins on the RAM chips If you have a newer style CPU board with a RAM daughterboard please contact OMNI at helpdesk omniflow com for additional assistance 4 Reinstall the CPU module 52 0001 0005 Rev C Y Omni Page 13 of 16 TB 980803C Upgrading Flow Computer Firmware 5 Apply power to the flow computer The OMNI display should now power up as follows RAM amp Calibrate Data Invalid Reconfigure amp Re Calibrate Using OMNI as Password 6 Enter the key press sequence Prog Setup Enter Enter Enter and the following screen will be displayed PASSWORD MAI NTENANCE Privileged Level 1 Level 1A Different scree
21. m protocol for the Modbus Type in Step 34 if it is available in your new EPROM version If you decide to use this protocol ensure that you make this same change in your OMNICOM configuration file under Config Serial I O before proceeding to download the configuration file to the OMNI SERIAL PORT 2 TX Key Delay Modbus ID Modbus Type 35 Print the configuration file from OMNICOM for DOS to your PC or network printer by using File Print and selecting your print option of LPT1 or LPT2 NOTE You must have the MS Windows virtual printer captured to an LPT port to print from OMNICOM for DOS Contact your IT department for assistance 52 0001 0005 Rev C Omni Page 12 of 16 TB 980803C Upgrading Flow Computer Firmware In OMNICOM for Windows use the Configure Configuration Print Print Report feature 36 Open Offline OMNI Configuration Config Serial I O and ensure that the Modbus Type is set correctly to match what you selected in Step 34 37 In OMNICOM for DOS go to Online Start Comm Check the Modbus ID Comm Port Baud Rate and Comm Media settings to ensure that these are correct If you set the port in Step 32 to Modbus RTU modem protocol ensure that Comm Media is set to Modem in OMNICOM for DOS NOTE If using OMNICOM for Windows you would set the media type in the Edit Sites Media Type setting when configuring a site to connect to You would then press on the globe icon on the menu bar at the top of
22. ns will be displayed each time you press enter before you reach the above screen 7 Atthe Privileged prompt enter the following key press sequence to use OMNI as the privileged password Alpha Shift Alpha Shift O M N I Enter The cursor will move down to the next entry PASSWORD MAI NTENANCE Privileged OMNI Level 1 Level 1A 8 Pres Prog four 4 times and the OMNI will display the Status screen showing the status of each of the hardware modules Message Cannot Open File is Displayed when Trying to Transmit the Saved Report Templates to the OMNI Go to the OMNICOM for DOS pull down Report menu and open each of the reports templates individually make the necessary changes and resave the reports If you see a blank page this means you are not using custom report templates The change can simply represent change to the same thing it was before Save the template using ALT S exit OMNICOM and restart OMNICOM Open the file and transmit the custom report templates Incorrect Data In Printed Customized Reports When upgrading EPROMs and using customized reports the data in the printed report may not be correct because some of the database registers may have changed moved or been redefined in the new version with respect to the old version If you see that printed data is not what was expected then you should open the report template files to check if the data is being retrieved from the correct registers for
23. ore you can attempt to go online to receive the configuration from the flow computer If you create a new file using the File Create feature you will be prompted for a filename and a revision of file to create Choose the revision of file that matches the version of EPROMs currently installed in the flow computer Subsequently receive ALL the custom report templates by selecting Receive Report Templates within the Online Start Comm menu As a precautionary measure this should be done regardless of whether or not custom report templates are being used in the OMNI Close the OMNICOM for DOS program by selecting Exit from the File menu You will be prompted on whether to save the configuration file and each of the report templates Answer Yes to all Install and then start the OMNICOM for Windows program Using the File Import feature import the OMNICOM for DOS configuration file you saved in the previous step NOTE The file will have a OMI extension and will be located in the appropriate application subdirectory under the OMNICOM for DOS install directory Example file to import C OMNICOM OMNI20 ABC OMI Select the Reports icon at the top menu bar in OMNICOM for Windows Highlight each of the report templates individually on the left side menu tree and use the File Import feature to individually import the OMNICOM for DOS custom report templates The four 4 OMNICOM for DOS report templates will be in the same directory as the configuration f
24. the I O configurations to be cleared Exit the Program Mode when you are done by pressing the Prog key repeatedly until the Program LED above the keypad goes out This returns you to the Display Mode 52 0001 0005 Rev C Omni Page 10 of 16 TB 980803C Upgrading Flow Computer Firmware Setting the Number of Digits and Decimal Places for Totalizers 27 In some newer versions of EPROMS you are given an option to set the number of digits for cumulative totalizer rollover 8 or 9 digits and the number of decimal places for volume and mass totalizers Set these options via keypad ONLY by pressing Prog Setup Enter Enter Enter The following screen will be displayed Different screens will be displayed each time you press enter before you reach the previous screen 28 At the Privileged prompt enter the following key press sequence to use OMNI as the privileged password Alpha Shift Alpha Shift O M N I Enter The cursor will move down to the next entry PASSWORD MAI NTENANCE ivi OMNI Reset All Totals Totals Now Reset Totalizer Resolution Ae 0 9 1 8 0 DecPlacesGross amp Net 0 Decimal Places Mass 3 Enter the respective values you want for each and every totalizer resolution setting and press the Enter key after each entry NOTE Setting the Number of Digits for Totalizers Totalizers within the flow computer can be rolled at 8 or 9 significant digits To set totalizer rollover to 9
25. ting with the flow computer ensure that your MS Windows processor scheduling setting is configured for Background Services to allow equal amounts of processor time to all resources Sometimes you are unable to communicate to an OMNI after replacing the EPROMs This may be caused by the following e The OMNICOM for DOS Start Comm Comm Media setting differs from the OMNI Flow Computer Modbus Type setting in the serial port setup In the newest versions of EPROMs when the flow computer is powered up the EPROMs default to Modbus RTU Modem for Serial Port 2 The Modbus RTU Modem protocol is the preferred protocol instead of the Modbus RTU protocol therefore make this change in your OMNICOM configuration file AND also set the Comm Media to Modem in the Online Start Comm menu NOTE If using OMNICOM for Windows ensure that when you configured a site in the Edit Sites menu that you specified Direct for the Media Type setting if you have a direct serial connection to the OMNI In OMNICOM for Windows only if you have an actual modem should you set the type of connection as Modem e The new EPROMs default to Modbus ID 1 on power up Ensure that your Modbus ID matches in both the Online Start Comm menu and in the serial port setup in the OMNI Also ensure the OMNICO lt configuration file OMNI serial port and OMNICOM Start Comm screen are all set to the same Modbus ID NOTE In OMNICOM for Windows this setting is found in the Configure
26. ve Save and Print the Omni Configuration amp Custom Report Templates msan newest OmniCom for DOS Note Do not install into the same directory as old OmniCom Y Use the File New feature to create a new configuration file that matches the version of new EPROMs you will be installing CEEE Retrieve configuration file and custom report templates from Omni and make any necessary changes to the settings Exit and Save all files NO Pa Y See Separate flowchart related to Windows xx 74 EPROMs n Perform a Reset all RAM operation via the Front Keypad Y Power Down The Omni and Remove the Old EPROM s install the new EPROM s Power Up the Omni amp Enter the Privileged Password OMNI Refer to Troubleshooting Tips in Technical Bulletin TB980803b if Omni does not power up properly A x IMPORTANT Scroll down amp Perform a Reset All RAM Operation v Y After the Omni power cycles enter the Privileged Password OMNI again and configure a serial port for communication with OmniCom for DOS Using te new OmniCom for DOS open your new Configuration File saved in an earlier step Y Transmit Configuration File amp Custom Report Templates to the Omni Calibrate Analog l O s if necessary and check User Entered Data settings and Operation of the Omni Figure 1 Recommended Procedure for Upgrading OMNI 3