Home

User manual - Stoltronic

image

Contents

1. II 3D Ex tc IIIC T82 C IP64 X Ex II 3D Ex tc III C T 65 C IP64 X 182 C special conditions Type of protection Temperature Subgroup IEC CENELEC Group IEC CENELEC Ignition protection type IEC CENELEC Labeling IEC CENELEC Device category ATEX Device group ATEX Ex labeling ATEX Device QrOUDP ccceseccseseeceeseesenseesenseesees Il potentially dust explosive areas Device CATCQOLY ccccessccesenseeeeeeneeeeeenseeees 3D Zone 22 adequate safety with normal operation Ignition protection type cccccceeeeseees tc Protection by enclosure with adherence to the type of protection and within the surface temperature limits Ex atmosphere cannot be ignited ON stage to es een ease weenie ERE lll potentially dust explosive areas SUDOrOUDP sapan aaa C Type of dust conductive dust Temperature PROFIBUS variant eeen T65 C max enclosure surface temperature lt 65 C PROFINET variant cccccccssseeeeees T82 C max enclosure surface temperature lt 82 C 2 Protection ClASS cccccccsssseseeeeeeeeeeesees IP64 Degrees of protection provided by enclosures according to DIN EN 60529 Special CONItIONS ccsssseeeeeeeesseeeeees X see chapter 2 11 on page 13 2 Observe instructions for plug connections mating plugs see chapter 2 11 on page 13 TR Electronic GmbH 2013 All Rights Reserved Printed in the Federal Republic of Germany Page 16 of 22 TR ECE BA GB 0099 04
2. 04 25 2013 electronic Equipotential bonding conductor Connection 4 Equipotential bonding conductor Connection An equipotential is required for systems in potentially explosive areas This is to be done through one of the four attachment screws of the connection cover and with a minimum wire diameter of 4 mm 1 M4 attachment bolt Not included 2 Locking element 3 Cable lug Figure 1 Equipotential bonding conductor Connection Printed in the Federal Republic of Germany TR Electronic GmbH 2013 All Rights Reserved 04 25 2013 TR ECE BA GB 0099 04 Page 17 of 22 Annex TRelectronic 5 1 EC declaration of conformity PROFIBUS variant Expansion in Automation electronic EC Declaration of Conformity The Rotative Measuring System Series ADx75M SIL3 PROFIsafe via PROFIBUS with Explosion Protection Enclosure Type ADV75M ADH75M Order No ADV75M xxxxx ADH75M xxxxx was developed designed and manufactured to comply with the EC directive 2004 108 EC L 390 24 Electromagnetic Compatibility and EC directive 2006 42 EC L 157 24 Machinery and EC directive 94 9 EC ATEX Equipment and protective systems intended for use in potentially explosive atmospheres under the sole responsibility of TR Electronic GmbH Eglishalde 6 D 78647 Trossingen Teks 49 7425 228 0 Fax 49 7425 228 33 Germany The following harmonized standards were applied EN 61000 6 2 200
3. TRelectronic 5 3 Accessories 5 3 1 Interface specific user manuals Document No Description Absolute Encoder Series CDx 75 with PROFIBUS DP interface Dp omer eves and PROFIsafe profile Absolute Encoder Series CDx 75 with PROFINET interface and TE EUT BAROSS PROFIsafe profile TR Electronic GmbH 2013 All Rights Reserved Printed in the Federal Republic of Germany Page 22 of 22 TR ECE BA GB 0099 04 04 25 2013
4. in potentially explosive areas are tested by the company TR Electronic GmbH and confirmed by identification with the ATEX nameplate Printed in the Federal Republic of Germany TR Electronic GmbH 2013 All Rights Reserved 04 25 2013 TR ECE BA GB 0099 04 Page 7 of 22 Basic safety instructions electronic instructions 2 1 Symbol and note definition means that death or serious injury can occur if the required A WARNING precautions are not met means that minor injuries can occur if the required A CAUTION precautions are not met means that damage to property can occur if the required NOTICE precautions are not met indicates important information or features and application tips for the product used 2 2 General dangers with the use of this product The product hereafter referred to as equipment is manufactured using the latest technology and according to recognized safety regulations Nevertheless non intended use can cause danger to life and limb of the user or third parties or cause damage to the equipment and other property Only use the equipment for its intended use with safety and danger awareness and in compliance with the user manual and the interface specific user manual The operator of an electrical system in a potentially explosive environment should keep the equipment in a proper condition it should be properly operated and monitored and maintenance as well as repairs are to be
5. 4 25 2013 TRelectronic General 1 3 Used abbreviations Terms Explosion protection enclosure with integrated measuring system of povrs the CDV75 series Explosion protection enclosure with integrated measuring system of the CDH75 series Absolute encoder with redundant dual scanning solid shaft design Absolute encoder with redundant dual scanning hollow shaft design European community Electromagnetic compatibility Electro Static Discharge International Electro technical Commission Verein Deutscher Elektrotechniker Association of German Electrical Engineers 1 4 Product description The aluminum explosion protection enclosure with built in systems and integrated evaluation electronics serves the detection of changes in angle for fixed installations The changes in angle are transmitted to the evaluation electronics via shaft The explosion protection enclosure has the ignition protection type e n non sparking operating equipment potential gas explosive atmosphere and e t protection by the enclosure potential dust explosive atmosphere Through its manner of construction the types of ignition protection and additional measures the enclosure is suitable for the incorporation of non explosion protected installation devices such as the measuring system of the series CDV75 or CDH75 The construction as well as the interaction of the individual components and the housing with regards to their possibilities for use
6. 5 AC 2005 with increased test Generic standards Electromagnetic compatibility standards DIN IEC 61326 3 2004 Immunity Industrial environments EN 61000 6 3 2007 A 1 2011 Generic standards lt Electromagnetic compatibility Emissions Commercial environments Adjustable speed electrical power drive systems EN 61800 5 2 2007 J oF p y Safety requirements Functional EN ISO 13849 1 2008 AC 2009 Safety of machinery Safety related parts of control systems General principles for design Safety of machinery Electrical equipment of machines EN 60204 1 2006 AC 2010 in extracts a aiai oaas w i bas J gt a gt Safety of machinery Functional safety of safety related electrical EN 62061 2005 AC 2010 doe eid electronic and programmable electronic control systems EN 60079 0 2009 Explosive atmospheres Part 0 Equipment General requirements Explosive atmospheres 15 2 EN 60079 15 2010 Part 15 Equipment protection by type of protection n Explosive atmospheres EN 60079 31 2009 A oe a ne Part 31 Equipment Dust ignition protection by enclosure t Page 1 of 2 TR ECE KE GB 0322 01 DOC TR Electronic GmbH 2013 All Rights Reserved Printed in the Federal Republic of Germany Page 18 of 22 TR ECE BA GB 0099 04 04 25 2013 Annex Exfansion in Automation electronic Other applied standards DIN EN 61508 Part 1 7 2010 Functional safety of electrical electronic programm
7. Electronic GmbH 2013 All Rights Reserved Printed in the Federal Republic of Germany Page 2 of 22 TR ECE BA GB 0099 04 04 25 2013 TRelectronic Table of contents Table of contents TAT ORC OTS TINS acs staat ac en cee eee E E EEA 3 AMEndmen Nde ace caps es ese E EA E 4 WON EE A E A E E A N A A A E A A A 5 ESE o EEA E ee AE E E E E EAT eee 5 1 2 Relevant directives and Standards ccccccccccsseeseeeeeeeeeeceeeceeeeeeeeesseeeeeeeesseaeeeeesseaseeesessaaess 6 1 3 Used abbreviations T CLINGS icccis snsceecectdnsanshccuddnvoswecdesnpetecwonauageschdussumanduaddaaweedcdeanawehiashdoaedescawes 7 e aes Weie CE eg ea APAE E E ATE E E E E N E 7 2 Basie Safety NSUUCHONS siseses Eaa Oa Daaa 8 2 1 SympbOkand NOLS CET IT OM serina a a Ge swentthceeesauaros 8 2 2 General dangers with the use of this DrOCUCT cccccceecceeeeeeeceeeeeeseeeeeeeeeeeeeseseeeeeeeeeeeeeaaas 8 2 3 Intended USC cceeecccccceessececccaeesececccsuaececccaauseceessuaueeceesauaaeeeesssaaeeeeessaaaeeeeesseageeeeessaaneeeeesaas 9 2 4 Non intended USE cscseecccccsesseeeccceassececccaeuseceecseaaseeeesseuaeeeecseaaseeeesseaaseeecsseaeeeeessagseeseeseas 9 25 Waranty ana Mably s cissnaeriricuintiresectcisanenanieleadsciesaitaesevexonely a EEEE TE E T ET 10 2 6 Organizational MEASUMES cccccccccecceesesseeceeeeecseeesseeceeeeeeesaessseceeeeseseaaaseeeeeeesssaeaeseeeeeeeeeaaas 10 2 Personnel selection and qualification basic obligat
8. I3D Ex tc IlIIC T65 C IP64 X PROFINET variant ADV75 ADH75 e Gas 113G Ex nAc IIC T6 X e Dust II13D Ex tc IlIC T82 C IP64 X The products are labelled with affixed nameplates and are components of a system lt thus applies together with the following documentation e the operator s system specific operation instructions e this User manual e and the interface specific user manual Printed in the Federal Republic of Germany TR Electronic GmbH 2013 All Rights Reserved 04 25 2013 TR ECE BA GB 0099 04 Page 5 of 22 General TRelectronic 1 2 Relevant directives and standards The explosion protection enclosure is developed constructed and finished under compliance with the applicable European or International standards and directives Equipment and protective systems intended for use in potentially explosive atmospheres EC Directive 94 9 EC ATEX Explosive atmospheres EN 60079 0 2009 General requirements Explosive atmospheres EN Uaioe te Electrical installations design selection and erection Explosive atmospheres EN 60079 15 2010 Equipment protection by type of protection n Explosive atmospheres EN 60079 31 2009 Equipment dust ignition protection by enclosure t Degrees of protection provided by enclosures DIN EN 60529 2000 IP code TR Electronic GmbH 2013 All Rights Reserved Printed in the Federal Republic of Germany Page 6 of 22 TR ECE BA GB 0099 04 0
9. Rotary Linear Encoders Motion Encoders Translation of the original manual 113 G Ex nAc IIC T6 X x Il 3 D Ex tc IIIC T65 C T82 C IP64 X x User manual Explosion protection enclosure ADV75 ADH75 with integrated measuring system series CDV75 CDH75 electronic TR ECE BA GB 0099 04 04 25 2013 TRelectronic TR Electronic GmbH D 78647 Trossingen Eglishalde 6 Tel 0049 07425 228 0 Fax 0049 07425 228 33 E mail info tr electronic de http www tr electronic de Copyriht This manual including the therein contained images is protected by copyright Third party usage of this manual which deviates from copyright provisions is prohibited Reproduction translation as well as electronic and photographic archiving or modification requires the author s written authorization Infringements will lead to liability for damage compensation The right to amendment is reserved The right to make any changes in the interest of technical progress is reserved Document information Edition Rev Date 04 25 2013 Document Rev No TR ECE BA GB 0099 04 File name TR ECE BA GB 0099 04 DOC Author MUJ Ce Cursive or bold text represents the title of a document or is used for emphasis Courier text shows text which is visible on the display or screen as well as software menu selections lt gt refers to keys on your computer keyboard e g lt RETURNS gt TR
10. able electronic safety related systems Explosive atmospheres icici Part 14 Electrical installations design selection and erection DIN EN 60529 2000 Degrees of protection provided by enclosures IP code The products are marked additionally with the following characteristics on the ATEX name plate 113G Ex nAc IIC T6 X 11 3D Ex tc IIIC T65 C IP64 X The EC type examination and certification according to the EC machinery directive as Logic Unit For Safety Functions was carried out by the notified body NB0035 T V Rheinland Industrie Service GmbH Alboinstr 56 12103 Berlin Certificate No 01 205 5241 12 Authorized to compile the technical file TR Electronic GmbH Eglishalde 6 78647 Trossingen Germany Trossingen 04 22 2013 Fnul ONG Thanassakis Andreas Business Management Page 2 of 2 TR ECE KE GB 0322 01 DOC Printed in the Federal Republic of Germany TR Electronic GmbH 2013 All Rights Reserved 04 25 2013 TR ECE BA GB 0099 04 Page 19 of 22 Annex electronic 5 2 EC declaration of conformity PROFINET variant ExZansid nin Automation electronic EC Declaration of Conformity The Rotative Measuring System Series ADx75M_ SIL3 PROFIsafe via PROFINET with Explosion Protection Enclosure Type ADV75M ADH75M Order No ADV75M xxxxx ADH75M xxxxx was developed designed and manufactured to comply with the EC directive 2004 108 EC L 390 24 Electromagnetic Compatibi
11. e classification during their training Personnel are to undergo appropriate further training or instruction regularly Proof of the relevant experience and completed training must be available For definitions on the knowledge expertise and competence of the responsible persons expert person with leadership functions and the performing personnel the IEC 60079 17 or DIN EN 60079 17 standards are to be additionally consulted suppliers e g Beuth Verlag publishers GmbH VDE Verlag GmbH Printed in the Federal Republic of Germany TR Electronic GmbH 2013 All Rights Reserved 04 25 2013 TR ECE BA GB 0099 04 Page 11 of 22 Basic safety instructions electronic 2 8 First commissioning Commissioning Prior to the first commissioning the equipment is to be checked regarding its suitability in the respective zone according to its labeling The values indicated on the nameplates are not to be exceeded With use of the equipment in areas which are potentially explosive because of dust a deposit of dust on the top side which is more than 5 mm thick is not permissible Here the installation of an additional covering may be required in circumstances where the deposit of dust cannot be reliably avoided The operational safety of the equipment and the correct functional arrangement of the equipment inside the plant must be checked before commissioning It may only be used in a clean and undamaged condition 2 9 Assembly i
12. ermany Page 10 of 22 TR ECE BA GB 0099 04 04 25 2013 electronic Basic safety instructions 2 7 Personnel selection and qualification basic obligations 2 7 1 Electrical installations design device selection and erection The project development of electrical systems the selection of the devices and the installation in potentially explosive atmospheres may only be performed by persons whose training includes instruction in various types of ignition and installation techniques applicable regulations and prescriptions as well as general principles of the Zone classification The persons must have the relevant competence for the type of work to be performed The personnel must regularly undergo corresponding further training or courses For definitions on the knowledge expertise and competence of the responsible persons manual workers and planners the IEC 60079 14 or DIN EN 60079 14 standards are to be additionally consulted suppliers e g Beuth Verlag GmbH VDE Verlag GmbH 2 7 2 Inspection maintenance and repair The inspection maintenance and repair of electrical systems in potentially explosive environments may only be performed by experienced personnel who have also gained knowledge on the various types of ignition and installation procedures the requirements of the IEC DIN EN 60079 17 standard relevant national provisions and company regulations for the system as well as on the general principles of the Zon
13. ion protection by enclosure t Page 1 of 2 TR ECE KE GB 0326 00 DOC TR Electronic GmbH 2013 All Rights Reserved Printed in the Federal Republic of Germany Page 20 of 22 TR ECE BA GB 0099 04 04 25 2013 quulliay AY TRelectronic Annex ExZansio nin Automation electronic Other applied standards Functional safety of electrical electronic programmable electronic DIN EN 61508 Part 1 7 2010 maia i safety related systems Explosive atmospheres Part 14 Electrical installations design selection and erection DIN EN 60079 14 2012 DIN EN 60529 2000 Degrees of protection provided by enclosures IP code The products are marked additionally with the following characteristics on the ATEX name plate Il 3G Ex nAc IIC T6 X II 3D Ex tc IIIC T82 C IP64 X The EC type examination and certification according to the EC machinery directive as Logic Unit For Safety Functions was carried out by the notified body NB0035 T V Rheinland Industrie Service GmbH Alboinstr 56 12103 Berlin Certificate No 01 205 5338 13 Authorized to compile the technical file TR Electronic GmbH Eglishalde 6 78647 Trossingen Germany Trossingen 08 09 2013 Fannt d e Thanassakis Andreas Business Management Page 2 of 2 TR ECE KE GB 0326 00 DOC Printed in the Federal Republic of Germany TR Electronic GmbH 2013 All Rights Reserved 04 25 2013 TR ECE BA GB 0099 04 Page 21 of 22 Annex
14. ions eeececceeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 11 2 1 Electrical installations design device selection and erection ccccccseeeeeeeeeees 11 2 7 2 INSPECTION MAINTENANCE and repair cccccsesecccaeeeeeeceeeeeeseeeeeeeuaeeeeeseeeeeeseeeeeeseess 11 2 8 First COMMISSIONING COMMISSIONING ccccccecseeeeeeeeceeeecaeeeeseceeeeeesaeeeeeceeeeessuaaaeeeeeeeeeeaaas 12 2 9 Assembly installation ANd dismantling ccccccccseeeeceeeeaeeeeeeeceeeeseeeeeeeeaseeeeeeeeaseeeeeesaseeeeeeeas 12 2 10 Inspection MAINTENANCE ANC repair ccccseecccccseseeeceeeeeecceueeeeeseeeeseeeeeeesseeeesseeeeessaeeeeesaaes 13 2 11 Special conditions for safe USE marking KX see ceceeccseeeeeeeeeaeeeeeeeeseeeseeeeeeeeeeeeeesaeeseeeeeeas 13 3 TOGA GAN CAN testi terse cpenisccceecn este ce sone ES E N EE E 14 SHMC a fa eee ne ee A ea eee ee ee one ene eee 14 3 2 Explosion protection characteristics ccccseeecccceeeeeeseeeeeeseeseeeseeseeeeseaeeeesseeeessageeessaeeeessaess 15 3 2 1 Ex labeling gas aise citer x too see aiesadadnesdsanecoeeeseestrentee eueseedeeseanees Gece stout eeetet unease 15 3 2 2 EX laDeCliNG GUS trcs Enr EE EEE Aa Ei E 16 4 Equipotential bonding conductor Connection sssssssnssussnnnrnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nenna 17 SADNE aenn E E E a 18 5 1 EC declaration of conformity PROFIBUS Variant cc cecccccseecceceeeeeeeeeeeceeseeeeeeseeeeeeeeeees 18 5 2 EC declara
15. lity and EC directive 2006 42 EC L 157 24 Machinery and EC directive 94 9 EC ATEX Equipment and protective systems intended for use in potentially explosive atmospheres under the sole responsibility of TR Electronic GmbH Eglishalde 6 D 78647 Trossingen Tel 49 7425 228 0 Fax 49 7425 228 33 Germany The following harmonized standards were applied EN 61000 6 2 2005 AC 2005 with increased test Generic standards Electromagnetic compatibility standards DIN IEC 61326 3 2004 Immunity Industrial environments Generic standards Electromagnetic compatibility EN 61000 6 3 2007 A 1 2011 m Emissions Commercial environments Adjustable speed electrical power drive systems a By Te C EE aR Safety requirements Functional EN ISO 13849 1 2008 AC 2009 Safety of machinery Safety related parts of control systems General principles for design Safety of machinery Electrical equipment of machines EN 60204 1 2006 AC 2010 in extracts General requirements S Safety of machinery Functional safety of safety related electrical EN 62061 2005 AC 2010 eae Oe D nee wa Malai electronic and programmable electronic control systems Explosive atmospheres M o 3 EN 60079 0 2009 Part 0 Equipment General requirements Explosive atmospheres 5 14 9 BN 60073 15 2010 Part 15 Equipment protection by type of protection n Explosive atmospheres 31 2 EE heer Part 31 Equipment Dust ignit
16. nnections may only be performed with the power switched off TR Electronic GmbH 2013 All Rights Reserved Printed in the Federal Republic of Germany Page 12 of 22 TR ECE BA GB 0099 04 04 25 2013 electronic Basic safety instructions 2 10 Inspection maintenance and repair The operator of an electrical system in a potentially explosive environment must keep the equipment in an good condition operate it properly monitor it and maintenance and repair work must be performed also see IEC 60079 17 and DIN EN 60079 17 in this respect Maintenance work and defect repairs may only be performed by trained professionals Before the maintenance or repair the specified safety precautions are to be observed The warning notes on the equipment and in the User manual and the interface specific user manual are to be adhered to The applicable laws and directives are complied with before recommissioning e The equipment does not require any maintenance by the operator Nevertheless inspections must be performed at regular intervals e Visual inspection of the enclosure for damages of the supply lines for external damages for dust deposits e Checking of the connection plug for a tight fit e n case of damages the equipment is to be taken out of service immediately and to be repaired by the manufacturer 2 11 Special conditions for safe use marking X The X symbol in the labeling of the equipment is used to indicate
17. nstallation and dismantling With installation and operation of the explosion protective equipment one should consider protection against hazardous environmental influences which limit the intended use of the equipment This could be protection against aggressive fluids or weather protection for example During installation the IEC 60079 14 and DIN EN 60079 14 as well as other national standards and regulations applicable at the installation site are to be adhered to The information on the nameplates must be complied with The assembly is to be performed according to the specifications in the interface specific user manual The coupling required for the mechanical connection of the ADV75 model s shaft to the drive must comply with the given specifications according to the interface specific user manual as well as be approved for use in potentially explosive areas The requirements for this are defined in the chapter Technical data starting on page 14 Here the manufacturer s installation instructions are to be adhered to In potentially explosive areas the equipment s power supply lines with mating connector are to be routed in such a way that they are protected from damages and mechanical failure The maximum connection information on the device nameplate must be complied with For metal enclosures in potentially explosive areas an equipotential line with at least 4 mm is required Wiring work opening and closing of electrical co
18. performed This also includes inspection of the equipment for possible transport damage prior to commissioning Power connections may not be connected or disconnected with the power engaged The equipment may not be used in case of defects as a basic principle it may not be opened and dust deposits gt 5 mm must be removed TR Electronic GmbH 2013 All Rights Reserved Printed in the Federal Republic of Germany Page 8 of 22 TR ECE BA GB 0099 04 04 25 2013 electronic Basic safety instructions 2 3 Intended use The equipment is a fixed installation device for use in the Ex Zone 2 potentially gas explosive areas Il 3 G device protection level Gc or 22 areas with combustible dust Il 3 D device protection level Dc The assembly is to be made exclusive by the specifications of the interface specific user manual The electrical data provided on the nameplates for the device and ATEX as well as the device category temperature class etc for the place of use are to be observed The operating temperature range of the equipment is e PROFIBUS variant 0 C to 40 C e PROFINET variant 20 C to 60 C Intended use also includes e observation of all instructions contained in this User manual and in the interface specific user manual e observation of the nameplates and possible prohibition or instruction labels e observation of the supplementary documentation e g the accompanying product sheet connecto
19. r assignments etc e observation of the machine or system manufacturer s operating manual e operating of the equipment within the limits indicated in the technical data User manual interface specific user manual 2 4 Non intended use Risk of death bodily injury or damage resulting from non intended use of the equipment IIMWPN ININ M gt The following uses are especially prohibited in environments with an explosive atmosphere of the Zones 0 1 20 and 21 NOTICE for medical aims commissioning of the equipment if the nameplates are no longer readable or are completely missing Printed in the Federal Republic of Germany TR Electronic GmbH 2013 All Rights Reserved 04 25 2013 TR ECE BA GB 0099 04 Page 9 of 22 Basic safety instructions electronic 2 5 Warranty and liability The General terms and conditions Allgemeine Gesch ftsbedingungen of the company TR Electronic GmbH apply in general This will be available to the operator with the contract confirmation or conclusion at the latest Warranty or liability claims with regards to personal and property damage are excluded if they are the result of one or more of the following causes e Non intended use of the equipment e Improper assembly installation commissioning maintenance or dismantling of the equipment e Improperly executed work on the equipment by unqualified personnel e Operating of the equipment in the presence of
20. special application conditions The equipment s installation location and manner are generally to be selected in such a way that it is protected from external mechanical influences and in a way that no function limitations can result Misappropriations of the equipment as e support e tread plank e stirrup are prohibited Unused connection plugs must be provided with mating connectors which are appropriately licensed for the applicable device category All mating connectors must be secured against accidental disconnection through the use of a screw locking device Printed in the Federal Republic of Germany TR Electronic GmbH 2013 All Rights Reserved 04 25 2013 TR ECE BA GB 0099 04 Page 13 of 22 Technical data TRelectronic 3 Technical data 3 1 General Rated VON AGG ings ccesesccs cer ranceetuesatetermmedswideadi 24V DC Power CONSUMPTION cccceeeeeeeeeeeeeneeeeeen lt 4W Mechanically permissible speed lt 3000 min Ambient temperature range PROFIBUS variant cccceceeeeeeeeee 0 C 40 C PROFINET variant cccceeeeeeeee 20 C 60 C IP64 Degrees of protection provided by enclosures 1 Protection class c scsccesseeseeseeeeeseeeeees according to DIN EN 60529 Enclosure Flange material 008 Aluminum EN AW AlCu6BiPb Shaft stainless steel cccccsscseesesesenseeen WN 1 4305 corrosion resistant 1 Observe ins
21. technical defects e The performance of unauthorized mechanical or electrical modifications of the equipment e The performance of unauthorized repairs e Catastrophic incidents caused by external forces or acts of God 2 6 Organizational measures e The User manual must always be kept within reach in the equipment s operating location e In addition to the User manual the generally applicable legal regulations and other mandatory directives for work safety accident prevention and environmental conservation are to be observed and conveyed e The applicable national site and system specific provisions and requirements are to be observed and conveyed e The operator has the obligation to point out any special operational features and requirements to the personnel e Before starting work the personnel responsible for work on or with the equipment must have read and understood the User manual in particular the chapter on Basic safety instructions e The nameplates and possible affixed prohibition or instruction labels must be kept in a readable condition e Do not perform any mechanical or electrical modifications to the equipment except those which are specifically described in this User manual e Repairs may only be performed by the manufacturer or by a person or body who carries the manufacturer s authorization TR Electronic GmbH 2013 All Rights Reserved Printed in the Federal Republic of G
22. tion of conformity PROFINET variant cccccccccceeeceeceeeeeeeeeeeeeeseeeeeseaeeeeeenens 20 8 FCC SOIC S oxi acre no E A E E ET A E E AE E E E AE E E EA 22 5 3 1 Interface specific user manuals cccseccccceseeeceeeeeceeseeecseseeeceaueeessaueeessenseeensass 22 Printed in the Federal Republic of Germany TR Electronic GmbH 2013 All Rights Reserved 04 25 2013 TR ECE BA GB 0099 04 Page 3 of 22 Amendment index TRelectronic Amendment index Amendment Date Index First edition 04 23 13 03 Additional indications for the PROFINET variant 04 25 13 04 TR Electronic GmbH 2013 All Rights Reserved Printed in the Federal Republic of Germany Page 4 of 22 TR ECE BA GB 0099 04 04 25 2013 TRelectronic General This User manual contains all relevant explosion safety information and includes the following topics Basic safety instructions Intended use Product description Technical data Explosion protection characteristics Since the documentation has a modular structure this User manual represents a supplement to the other documentation such as for example product data sheets dimensional drawings and leaflets etc The User manual is included but can also be ordered separately 1 1 Scope This User manual applies exclusively to the following explosion protection enclosure series PROFIBUS variant ADV75 ADH75 Gas Il 3G Ex nAc IIC T6 X Dust I
23. tructions for plug connections mating plugs see chapter 2 11 on page 13 TR Electronic GmbH 2013 All Rights Reserved Printed in the Federal Republic of Germany Page 14 of 22 TR ECE BA GB 0099 04 04 25 2013 TRelectronic Technical data 3 2 Explosion protection characteristics 3 2 1 Ex labeling gas 3G Ex nAc IIC T6 X amp Il 3G Ex nAc Il C T6 X special conditions Temperature IEC CENELEC Subgroup IEC CENELEC Group IEC CENELEC Ignition protection type IEC CENELEC Labeling IEC CENELEC Device category ATEX Device group ATEX Ex labeling ATEX Devic Grou sanse Il potentially gas explosive areas Device category ssssnnnnunnnnnrnnnnnnnnnnnnnnnnnn 3G Zone 2 adequate safety with normal operation Ignition protection type sssssssssnnssnnnnnnnnnn nAc non sparking equipment Ex Atmosphere cannot be ignited in case of defined malfunction conditions GOUD aiaa senate eiet Il potentially gas explosive areas UIP OUD seia C typical gas Hydrogen acetylene ENVAD CRU Osio T6 max enclosure surface temperature lt 85 C Special CONItIONS c ccceeeeeeeesseeeeeeeeees X see chapter 2 11 on page 13 Printed in the Federal Republic of Germany TR Electronic GmbH 2013 All Rights Reserved 04 25 2013 TR ECE BA GB 0099 04 Page 15 of 22 Technical data TRelectronic 3 2 2 Ex labeling dust PROFIBUS variant amp II 3D Ex tc IIIC T65 C IP64 X PROFINET variant